Loading...
HomeMy WebLinkAboutRevisions; Shop Truss DrawingOFFICE USE ONLY: DATE FILED: �2o �� I REVISION FEE: PERMIT # 20 /0 — U 2,7l RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERM=T D.E'FERRA�. PROJECT INFORMATION OV, LOCATION/SITE ADDRESS: 9563 S OCEAN DR BLD F, JENSEN BEACH, FL 34957 DETAILED DESCRIPTION OF PROJECT REVISIONS: Shop Truss Drawiings l CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: HOOKS CONSTRUCTION CO LLC QUALIFIERS NAME: STEVEN C HOOKS ADDRESS: 2211 S KANNER HWY CITY: STUART STATE: FL PHONE (DAYTIME): (772) 419-8828 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 07117118 STATE: ST. LUCIE CO CERT. #: 25620 ZIP: 34994 FAX: (772) 237-3757 FAX: FAX: ZIP: ZIP: ::..STRUCTURAL SUBMITTAL EVALUAT[W Nth ?tCEPT(UNS NOTED.:,.....;. REVIEWED. NO CORRECTIONS NOTED. Q :EXCEPTIONS AS.NOTED......_... MAKE CORRECTIONS AS NOTED NO ES RUBMITTAL REWIRED. REVISE AND RESUBMIT'...-,'....'..... MAKE CORRECTIONS AS NOTED &`RESUBMIT DOCUMENTS FOR REVIEW, .: CONTRACTOR APPROVAL........, 0 SUBMITTAL SHALL BE•REVIEWED AND STAMPED AS APPROVED BY THE CONTRACTOR. PE SEAL AND SIGNATURE—.— _ . SIGN AND SEAL ENGINEERING:SUBP IITTAL AS . REQUIRED BY CONTRAGT DOCUAAENTS : :NO REVIE4S.,�..:....:;.......... _........ .: SUBM TTAL RETURNED WITHOUT SRS REVIVI u m s are" any wnewjedJdr,g.enqra1 co. ormance +n��th. the desi n .intent of the btructurat. ConstruWon' Documents. For dele gated 1 specialh� errg�neering snUrti�ttats, no detailed the of calculations is roads;. B,RS does not:waTraaht or represent that. the infamzafia6 contained in subbiittals. is either, accurate ..r complete:. The General Contractor / Construction Manager is . sole[ responsible for confirming -all quantitles, ftiensions,' details, means and methods of: yy q construciion; cooidmating Wo*-ith,attrat trades, ai ii icar assuring'that. W9 ;s: erformed m a: . .......... safe and sa6fa0ory;rwr�ner. Noes of sutsrnittals �dp not cgnslbtute a change o er or _ Tecttve, and do not relieve the.C-eneral ConfractorJ Construction Manager.`frorn the obligahon:io comply ',iHM the;.Constnuehon Documents, or. anY oftt appTicablg "codes 2n or regulations, all of which . haws rio'City ovetthis submittal; . BOB RUDE 5TRl1CTURES, It�C., FT: MYERS, FL.�239)7?-777'I 05-10-21 GBR ...... DATE ;REVIENVI D BY: . ® Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. RECENED MiTek® JUL 19 2021 RE: J40924 - Baron Island StE eWg MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Tan1�a, 33610-4115 Customer Info: Benchmark III Corp. Project Name: Baron Island Storage Model: BuulcT1 g t Lot/Block: - Subdivision: Address: 9500 South Ocean Dr., - City: Jensen Beach State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020/TP12014 Design Program: MiTek 20/20.8.4 Wind Code: N/A Wind Speed: 165 mph Roof Load: 40.0 psf Floor Load: N/A psf This package includes 13 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T23417101 C01 4/2/21 2 T23417102 CO2 4/2/21 3 T23417103 CO3GE 4/2/21 4 T23417104 C04GE 4/2/21 5 T23417105 C05 4/2/21 6 T23417106 C06 4/2/21 7 T23417107 C07G 4/2/21 8 T23417108 ZCJ 1 4/2/21 9 T23417109 ZCJ3 4/2/21 10 T23417110 ZCJ5 4/2/21 11 T23417111 ZEJ6 4/2/21 12 T23417112 ZEJ6A 4/2/21 13 T23417113 ZHJ6 4/2/21 *JILtAtAr. to" PVPH%T, Colo - 0277 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by East Coast Truss. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2023. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/rPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design perANSI/TPI 1, Chapter 2. PQUI N 681:82 STATE OF : 44/� i0 <C/1% ® Joaquin Velez PE No.68182 C MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd:.Tampa FL 33610 Date: April 2,2021 Velez, Joaquin 1 of 1 MAY 7, 2019 LATERAL TOE -NAIL DETAIL MII-TOENAIL_SP-. MiTek USA, Inc. Page 1 of 1 1.NOWITH THE AND MUST HA EOE-NAILS SHALFULL WOOD SU PO TG (NAIL MUST BE DBE DRIVEN AT AN ANLE OF 45 RIVEN EN THROUGHMBER AND 0 0o EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. MiTek USA, Inc. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. WMMM i THIS DETAIL APPLICABLE TO THE A MiTek Affiliate THREE END DETAILS SHOWN BELOW OE -NAIL SINGLE SHEAR VALUES PER NDS 2018 (lb/nail) DIAM. SP DF HF SPF SPF-S 0 .131 88.0 80.6 69.9 68.4 59.7 p .135 93.5 85.6 74.2 72.6 63.4 .:I .162 108.8 99.6 86.4 84.5 73.8 ri z .128 74.2 67.9 58.9 57.6 50.3 0 .131 75.9 69.5 60.3 59.0 51.1 N .148 81.4 74.5 64.6 63.2 52.5 of VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d (0.162" X 3.5') NAILS WITH SPF SPECIES BOTTOM CHORD For load duration increase of 1.15: 3 (nails) X 84.5 (lb/nail) X 1.15 (DOL) = 291.5 lb Maximum Capacity ANGLE MAY VARY FROM 30 ° TO 60 ° 45.00 ° ANGLE MAY VARY FROM 30 *TO 60 ° VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW (2x3) 2 NAILS NEARSIDE NEAR SIDE SIDE VIEW (2x4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 45.00 ° SIDE VIEW (2x6) 4 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30 ° TO 60 ° 45.00 ° Job Truss Truss Type Qty Ply Baron Island Storage T23417101 J40924 C01 Common 45 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, a.4Ju s mar zz zudi mi i eK mausmes, Inc. I nu tipr -I ua:zw:.3U zlz I rage i ID:xfoRdl D442reVtwo7_GVjwy6ARY-oQuBuvBwpdWrBR6ZskZ46XIJnyiXLcx91_VONszVB1 p 5-4-3 10-2-13 15-1-7 20-5-10 5-4-3 4-10-10 4-10-10 5-4-3 Scale = 1:35.1 4x4 = 3x4 = 3x6 = 3x4 = 3x4 = 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) TCDL 12.0 Lumber DOL 1.25 BC 0.52 Vert(CT) BCLL 0.0 Rep Stress Incr YES WB 0.23 Horz(CT) BCDL 8.0 Code FBC2020rTP12014 Matrix -AS in floc) I/defl Ud 0.09 6 >999 , 360 -0.13 ' 6-8 >999 240 0.04 5 n/a n/a I I I LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 5=0-8-0 Max Horz 1=11(LC 5) Max Uplift 1=-715(LC 4), 5=715(LC 5) Max Grav 1=996(LC 9), 5=996(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-195911415, 2-3=-1753/1331, 3-4=1753/1331, 4-5=1959/1415 BOT CHORD 1-8=-120211739, 6-8=-687/1134, 5-6=1191/1739 WEBS 3-6=-393/577. 4-6=434/467. 3-8=-393/577. 2-8=-434/467 'PLATES GRIP MT20 244/190 Weight: 87 lb FT = 0% Structural wood sheathing directly applied. 4-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., GCpi=0.18; C-C Exterior(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 10-2-13, Exterior(2R) 10-2-13 to 13-2-13, Interior(1) 13-2-13 to 20-6-1; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 715 lb uplift at joint 1 and 715 lb uplift at joint 5. 8) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord. ,�'1111IIIfI1I E N S . F No 68182 :jam 0t S OF �i�SS��IVAIt �%%`�� Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall �p pV 11• building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IVI iTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabdeation, storage, delivery, erection and bracing oftrusses and truss systems, see ANSITP/1 Quality Criteria, DSB-99.and BCS/Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply Baron Island Storage T2341Z102 J40924 CO2 ATTIC 10 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, . 8.430 s Mar 22 2U21 Mi I eK Industries, Inc. I nu Apr 1 Ub:28:31 2U21 rage 1 ID:xfoRdl D442reVtwo7_GVjwy6ARY-GcSZ6EBYaxeipbhlPS4JekgMFM 1 N4?AIXeFZvIzVB1 o 3-7-5 6-9-1 8-7-4 9 4 6 10-2-13 11-1-4 11-10-q 13-8-9 16-10-5 20-5-10 3-7-5 3-1-12 1-10-3 0-9-2 0-10-7 0-10-7 0-9-2 1-10 3 3-1-12 3-7-5 Scale = 1:35.2 3x6 = 3x8 = 5 3x8 4x4 = I 3x4 = 3x8 M18SHS = 3x4 = 4x4 = 0-2-13 6-9-1 13-8-9 20-2-13 20510 0- - 3 6-6-4 6-11-8 6-6-4 0-2� LOADING (psf) SPACING- 2-0-0 CSI. DEFL. TCLL 20.0 Plate Grip DOL 1.25 TC 1.00 Vert(LL) TCDL 12.0 Lumber DOL 1.25 BC 0.60 Vert(CT) BCLL 0.0 Rep Stress Incr YES WB 0.49 Horz(CT) BCDL 8.0 Code FBC2020rTP12014 Matrix -AS Attic LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD BOT CHORD 2x4 SP M 31 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 9=0-8-0 Max Horz 1=11(LC 5) Max Uplift 1=-598(LC 4), 9=598(LC 5) Max Grav 1=1297(LC 10). 9=1297(LC 10) FORCES. (lb) -Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2898/1258, 2-3=-2402/912, 3-4=2110/878, 4-5=-571/1346, 5-6=-571/1346, 6-7=-2109/878, 7-8=-2402/912, 8-9=2898/1258 BOT CHORD 1-12=-1080/2629, 10-12=-596/2046, 9-10=1083/2629 WEBS 4-6=-3619/1588, 7-1 0=-1 36/580, 8-10=642/536, 3-12=136/580, 2-12=-642/536 in (loc) I/deft Ud -0.3410-12 >731 360 -0.59 10-12 >416 240 0.04 9 n/a n/a -0.17 10-12 483 360 PLATES GRIP MT20 244/190 M18SHS 244/190 Weight: 86 lb FT = 0% Structural wood sheathing directly applied. 4-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., GCpi=0.18; C-C Exterior(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 10-2-13, Exterior(2R) 10-2-13 to 13-2-13, Interlor(1) 13-2-13 to 20-6-1; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) 150.01b AC unit load placed on the top chord, 10-2-13 from left end, supported at two points, 3-0-0 apart. 5) All plates are MT20 plates unless otherwise indicated. 6) Plates checked for a plus or minus 0 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Ceiling dead load (5.0 psf) on member(s). 3-4, 6-7. 4-6 . 10) Bottom chord live load (30.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 10-12 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 598 lb uplift at joint 1 and 598 lb uplift at joint 9. 12) This truss design requires that a minimum of 71,16" structural wood sheathing be applied directly to the top chord. 13) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. `,tllIllllr/rrr �OPQUIN (, ENS+ No 68182 S OF •:�411 �.#fSS�0 N A S�%lf ��• 11111 Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.. �� Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage _ T23417103 J40924 CO3GE GABLE 2 Job Reference o tional East Coast Truss, Ft. Pierce, FL - 34946, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 1 05:29:33 2021 Page 1 ID:xfoRdl D442reVtwo7_GVjwy6ARY-D?ZJXwDo6YuQ2ur8Xt7nj9wjZ9f8Y_ObykgzBzVB1 m 5-4-3 10-2-13 15-1-7 20-5-10 5-4-3 4-10-10 4-10-10 5-4-3 ' �n d 2x4 = 4x4 = 1x4 Z' 3x4 = 3x6 = 3x4 = 1x4 \\ 3x8 = lx4 II 1x4 II 1x4 II 1x4 II 1x4 II 1x4 II 1x4 II Scale = 1:35.6 3x8 = LOADING (psf) TCLL 20.0 TCDL 12.0 BCLL 0.0 BCDL 8.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2020rTP12014 CSI. TIC 0.95 BC 0.78 WB 0.12 Matrix -AS DEFL. in Vert(LL) 0.11 Vert(CT) -0.11 Horz(CT) 0.02 (loc) Well 9-10 >999 6-7 >999 5 n/a ILid 360 240 n/a PLATES GRIP MT20 244/190 Weight: 272 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.1 BOT CHORD 4-0-0 oc bracing. WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 5=0-8-0 Max Horz 1=11(LC 14) Max Uplift 1=3538(LC 11), 5=3538(LC 14) Max Grav 1=3603(LC 16), 5=3603(LC 15) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-7820/7648, 2-3=-4781/4701, 34=4781/4701, 4-5=7820/7648 BOT CHORD 1-10=-6952/7148, 9-10=-5844/5987, 7-9=2369/2955, 6-7=-5834/5987, 5-6=6951/7148 WEBS 3-7=-512/589, 4-7=555/672, 3-9=-512/589, 2-9=-555/672, 2-10=-486/537, 4-6=-486/537 NOTES- 1) 2-ply truss to be connected together with 1Od (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom follows: 2x4 I N chords connected as - 1 row at 0-9-0 oc. Webs follows: ,,�� P(, ........ 0 F connected as 2x4'- 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ' `��, .•�\ C' E ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16: Vult=165mph (3-second Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., NO 68182 gust) GCpi=0.18; C-C Extedor(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 10-2-13, Exterior(2R) 10-2-13 to 13-2-13, In 13-2-13 to * �• •' 20-6-1; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 = .Q 5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIrrPI 1. •• S F ���,�'.• 6) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific Q ��,� to the use of this truss component. 7) Plates checked for a plus or minus 0 degree rotation about its center. Gable i� •. Q R \ �.•• \ �� ��� ss •' • • • • • •' �� �� spaced 9) This truss has been designed for 10.0 bottom live load live loads. a psf chord nonconcurrent with any other 10) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Joaquin Velez PE No.68182 will fit between the bottom chord and any other members. MITek USA, Inc. FL Cert 6534 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3538 lb uplift at joint 1 and 3538 lb 6904 Parke East Blvd. Tampa FL 33610 uplift at joint 5. Date: 12) This truss has been designed for a total drag load of 645 plf. Lumber DOL=(1.33) Plate grip DOL=(1.33) Connect truss to resist April 2,2021 drag loads along bottom chord from 0-0-0 to 20-5-10 for 645.0 plf. 13)-T ris-tfuss desigrxequires-thate-mirimum-ef-7H6'=stfuctufel-wood-sheathingAm-applied-direettt4G4he-tepcherd. ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/192020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not11' a truIMF system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall 1 building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417104 J40924 C04GE GABLE 10 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, i B.430 s Mar 22 2021 MI I ek Industries, Inc. Thu Apr 1 05:29:34 2021 rage 1 ID:xfoRdl D442reVtwo7_GVjwy6ARY-hB7hkGERtsOGg2PK5aeOGNS?mZ3THPxIDcTDWdzVB11 5-4-3 10.2-13 15-1-7 205-10 4 5-4-3 -10-10 4-10-10 5-4-3 c� a 3x4 = 3x4 = 1x4 II 1x4 II 2x4 = 4x4 = 13-5-14 3x6 = 3x4 = 1 x4 11 1 x4 11 1 x4 11 Scale = 1:35.6 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.47 Vert(LL) 0.09 6 >999 360 MT20 244/190 TCDL 12.0 Lumber DOL 1.25 BC 0.52 Vert(CT) -0.13 6-8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.23 Horz(CT) 0.04 5 n/a n/a BCDL 8.0 Code FBC2020/rP12014 Matrix -AS Weight: 131 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD 4-0-0 oc bracing. WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 5=0-8-0 Maio Horz 1=11(LC 5) Max Uplift 1=-715(LC 4), 5=715(LC 5) Max Grav 1=996(LC 9), 5=996(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-195911415, 2-3=-175311331. 34=1753/1331, 4-5=1959/1415 BOT CHORD 1-8=-120211739, 6-8=-687/1134, 5-6=1191/1739 WEBS 3-6=-393/577, 4-6=434/467, 3-8=-393/577, 2-8=-434/467 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. 11; Exp D; Encl., ,,�� ���, 1I,�, GCpi=0.18; C-C'Extedor(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 10-2-13, Exterior(2R) 10-2-13 to 13-2-13, Interior(1) 13-2-13 to ,,�'t v' N V 20-6-1; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 OPQ F�� ij♦ 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult building designer as ANSI/TPI 1. , ••�� G E fV 5$1 ♦�� qualified per 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific `�� to the use of this truss component. No 68182 5) Plates checked for a plus or minus 0 degree rotation about its center. * �• 6) Gable studs spaced at 1-4-0 oc. = 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. • 8) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide ;• SP"!oco) F ' will fit between the bottom chord and any other members.O 4�%� 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 715 lb uplift at joint 1 and 715 lb uplift at . 0 � • • TQ` •: joint 5. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord. ♦♦ R•.•` N �� ♦♦♦ Sl) •' ...... • ` %, ♦�y 0NAX- Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not • a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ■■iiYY building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek, is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage,' delivery, erection and bracing of trusses and truss systems, see ANStTP/t Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply Baron Island Storage T23417105 J40924 C05 Hip 2 1 Job Reference o tional East Coast Truss, Ft. Pierce, FL - 34946, 8.430 s Mar 22 2021 MTek Industries, Inc. Thu Apr 1 05:29:34 2021 Page 1 ID:xfoRdl D442reVtwo7_GVjwy6ARY-hB7hkGERtsOGg2PK5aeOGNSOhZ3THPVIDcTDWdzVB11 10-3-9 5-4-3 10.2-1 10. 13 15-1-7 20-5-10 5-4-3 4-9-14 0- • 2 4-9-14 5.4-3 G-0-12 Scale = 1:35.7 3x4 = 3x6 = 3x4 = 3x4 = 3x4 = r� Ics 0-. - 3 6-11-12 13-5-14 20-2-13 20-5-10 0- - 3 6-8-15 6-6-3 6-8-15 0.3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.41 Vert(LL) 0.08 6-14 >999 360 MT20 244/190 TCDL 12.0 Lumber DOL 1.25 BC 0.52 Vert(CT) -0.13 6-8 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.19 Horz(CT) 0.04 5 n/a n/a BCDL 8.0 Code FBC2020/TPI2014 Matrix -AS Weight: 87 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD 4-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 5=0-8-0 Max Horz 1=-12(LC 4) Max Uplift 1=-624(LC 4). 5=624(LC 5) Max Grav 1=996(LC 9),5=996(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1959/1196, 2-3=-1753/1131, 3-4=1753/1131, 4-5=1959/1196 BOT CHORD 1-8=-1024/1739, 6-8=-579/1139, 5-6=1012/1739 WEBS 4-6=-430/411, 2-8=430/411, 3-8=-331/573, 3-6=-331/573 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. 11; Exp D; Encl., GCpi=0.18; C-C Exterior(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 10-2-13, Extedor(2R) 10-2-13 to 14-5-12, Interior(1) 14-5-12 to 20-6-1; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific ,,�1 I N to the use of this truss component. ,�N PQU V �� �j� 4) Plates checked for a plus or minus 0 degree rotation about its center. �' O F �j 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. :� .•Ci E Ni 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. NO 68182 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 624 lb uplift at joint 1 and 624 lb uplift at joint 5. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the tap chord. O .00 POR Iii N s�O N AL E?�`,` Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeiC' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLTP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417106 J40924 C06 Hip 2 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 1 05:29:35 2021 Page 1 ID:xfoRd1 D442reVtwo7_GVjwy6ARY-9Oh4xcF3eA87IC_Xel9Fpa7CYzOvOtyuSGDn23zVB1 k 4-3-13 8-2-1 12-3-9 16-1-13 20-5-10 4-3-13 3-10-4 4-1-8 3-10-4 4-3.13 cr d 4x8 = 4x4 = Scale = 1:34.6 4x4 = 3x4 = 5x8 = 4x4 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 12.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 8.0 Code FBC2020rrPI2014 CSI. DEFL. in (loc) I/deft Ud TC 0.34 Vert(LL) -0.11 8-11 >999 360 BC 0.63 Vert(CT) -0.22 8-11 >999 240 WB 0.18 Horz(CT) 0.04 6 n/a n/a Matrix -AS LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 6=0-8-0 Max Horz 1=11(LC 5) Max Uplift 1=-660(LC 4), 6=660(LC 5) Max Grav 1=996(LC 9), 6=996(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=1996/1381, 2-3=-1610/1118, 3-4=1480/1109, 4-5=1611/1118, 5-6=1996/1381 BOT CHORD 1-8=-1203/1796, 7-8=-829/1387, 6-7=1192/1796 WEBS 2-8=-459/413, 3-8=107/286, 4-7=-136/286, 5-7=-458/414 PLATES GRIP MT20 244/190 Weight: 93 lb FT = 0% Structural wood sheathing directly applied. 4-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., GCpi=0.18; C-C Exterior(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 8-2-1, Exterior(2E) 8-2-1 to 12-3-9, Exterior(21R) 12-3-9 to 16-4-1, Interior(1) 16-4-1 to 20-6-1; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 660 lb uplift at joint 1 and 660 lb uplift at joint 6. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord. `1�111IIIfill,1 ��� PptU IN E N No 68182 0: S OF :�411 O N A E�0 11111 Joaquin Velez PE N0.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Val' valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Oty Ply Baron Island Storage T23417107 J40924 C07G Hip Girder 2 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.430 s Mar 22 2021 MTek Industries, Inc. Thu Apr 1 05:29:43 2021 Page 1 ID:xfoRdl D442reVtwo7_GVjwy6ARY-wwA5dLL4ld9?FRc36z177GKTtBAOuVv3l W9CKbzVB1 c 3-3 6 6-1-3 10-2-13 14-4-8 17-2-4 20-5-10 3-3 6 2-9-13 4-1-10 4-1-10 2-9-13 3-3 6 fh d 4x8 = 5.00 112 Special Special 1x4 II Special 48 = 22 4 23 5 Scale = 1:33.9 3x4 = 2x4 II 3x4 = Special 3x8 = 4x6 = 3x4 = 2x4 II 3x4 — HJC26 Special Special HJC26 l 0- - 3 3-36 6-1-3 10-2-13 14-0-8 17-2-4 20-2-13 20 510 0- - 3 3-0 9 2-9-13 4-1-10 4-1-10 2-9-13 3-0-9 0- - 3 Plate Offsets (X,Y)-[1:0-5-6,0-2-31,[3:0-5-4,0-2-01,[5:0-5-4,0-2-01,[7:0-5-6,0-2-31 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (]cc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) 0.21 11 >999 360 MT20 244/190 TCDL 12:0 Lumber DOL 1.25 BC 0.42 Vert(CT) -0.17 11 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.18 Horz(CT) -0.05 7 n/a n/a BCDL 8.0 Code FBC2020frP12014 Matrix -MS Weight: 230 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-11 cc purlins. BOT CHORD 2x6 SP No.2 BOT CHORD 4-0-0 cc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 7=0-8-0 Max Horz 1=-13(LC 4) Max Uplift 1=-2050(LC 4), 7=2049(LC 5) Max Grav 1=2260(LC 19), 7=2260(LC 19) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5190/4789, 2-3=-5122/4837, 3-4=-5436/5180, 4-5=-5436/5180, 5-6=5122/4839, 6-7=-5190/4791 BOT CHORD 1-13=-4355/4743, 12-13=-4355/4743, 11-12=-4368/4728, 9-11=-4357/4728, 8-9=-4344/4743, 7-8=-4344/4743 WEBS 2-12=-514/523, 3-12=-1154/1219, 3-11=-719/753, 4-11=696/813, 5-11=-718/753, 5-9=-1154/1219, 6-9=-514/523 NOTES- "xY) 1) 2-ply truss to be connected together with 10d (0.131 nails as follows: ,,�� /♦� 00 IN VF�� Top chords connected as follows: 2x4 - 1 row at 0-9-0 cc. Bottom ,,�," ........♦♦♦, chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 cc. Webs connected as follows: 2x4 - 1 row at 0-9-0 cc. E N $�. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to :� •,•�� ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. NO 68182 3) Unbalanced roof live loads have been considered for this design. * �� 4) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., GCpi=0.18; C-C Exterior(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 6-1-2, Exterior(2R) 6-1-2 to 10-2-13, Interior(1) 10-2-13 to 14-4-7, • Exterior(2R) 14-4-7 to 18-7-6, Interior(1) 18-7-6 to 20-6-1; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific : O F �• to the use of this truss component. O ♦ ,t' A, Q • _ 6) Provide adequate drainage to water ,� ♦i •. O 1, O \ prevent ponding. 7) Plates checked for a plus or minus 0 degree rotation about its center. R ••'`� ♦♦i♦ ss ........ • • • • • •' C>`, has been with l ive loads. ` '���1;� N Al E TThisrtruss live n �%%% load of 20.Opsf onlive has been designed foss r all areas where ant 9) the bottom chord rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. Joaquin Velez PE No.68182 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2050 lb uplift at joint 1 and 2049 Ib MITek USA, Inc. FL Cert 6634 uplift at joint 7. 69D4 Parke East Blvd. Tampa FL 33610 11) Use USP HJC26 (Wirth 16-16d nails into Girder & 1 Od nails into Truss) or equivalent spaced at 8-2-9 oc max. starting at 6-1-9 from Date: the left end to 14-4-2 to connect truss(es) to front face of bottom chord. April 2,2021 12) Fill all nail holes where hanger is in contact with lumber. -eontinued-on-pa ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE. �e Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Ma • building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417107 J40924 C07G Hip Girder 2 n L Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 3494b, oAOU 5 Mar 44 4U4I IVII I UK II1UUSlI1Ub, !I- I I1U ^PI I Vu.aa— cvc i rayc c ID:xfoRdl D442reVtwo7_GVjwy6ARY-wwA5dLL4ld9?FRc36z177GKTtBAOuVv3lW9CKbzVB1 c NOTES- 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 292 Ib down and 355 Ib up at 8-1-15, and 281 Ib down and 355 Ib up at 10-2-13, and 292 Ib down and 355 Ib up at 12-3-12 on top chord, and 64 Ib down and 37 Ib up at 8-1-15, and 64 Ib down and 37 Ib up at 10-2-13, and 64 Ib down and 37 Ib up at 12-3-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=64, 3-5=64, 5-7 64, 14-17=-16 Concentrated Loads (lb) Vert: 12=-706(F) 11=50(F) 4=112(F) 9=706(F) 22=-112(F) 23=112(F) 26=-50(F) 27=-50(F) A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall Mew ek• al" building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the IYIiT fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYMI Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417108 J40924 ZCJ1 Jack -Open 8 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, ' 8.430 s Mar 22 2021 MITek Industries, Inc. 1 hu,Apr 1 Ub:ZU:43 ZUZ1 rage 1 ID:xfoRdl D442reVtwo7_GVjwy6ARY-wwA5dLL4ld97FRc36z177GKcvBEDuXk31W9CKbzVB1 c 0-11-4 0-11-4 Scale = 1:6.8 C 0 d TRUSS MUST BE CONNECTED TO THE BEARINGS 2x3 = FOR ALL VERTICAL AND HORIZONTAL REACTIONS (BY OTHERS). Careful consideration should be given to bearing conditions. Bearings and truss to bearing connections should be designed in such a manner that they will safely withstand the lateral forces of the trusses. 0-11-4 0-11-4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL , 1.25 TC 0.19 Vert(LL) 0.00 6 n/r 120 MT20 244/190 TCDL 12.0 Lumber DOL 1.25 BC 0.15 Vert(CT) -0.00 6 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 8.0 Code FBC2020/TPI2014 Matrix -MP Weight: 3 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc puriins. BOT CHORD 2x4 SP No.3 BOT CHORD 4-0-0 oc bracing. REACTIONS. (size) 2=Mechanical, 3=Mechanical Max Horz 2=-264(LC 4), 3=330(LC 4) Max Uplift 2=-314(LC 4) Max Grav 2=77(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-367/97 BOT CHORD 1-3=-82/330 NOTES- 1) Wind: ASCE 7-16; VuK=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., GCpj=0.18; C-C Exterior(2E); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 _ 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. ,,�� ,' 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ♦♦OP,QU 1 N VF- 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. ``�� .'�\ G E IV SF• �i� 7) Refer to girder(s) for truss to truss connections. ' 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 314 lb uplift at joint 2. No 68182 S F •� '611111 Joaquin Velez PE No.68182 MITek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ° Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Lao building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Welk' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYM11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417109 J40924 ZCJ3 Jack -Open 8 1 Job Reference o tional East Coast Truss, Ft. Pierce, FL - 34946, m4su s mar zz zuzl mi I eK InOUstrieS, Inc. I nu Hpr 1 UD:Zy:44 ZUz"I rage - ID:xfoRdlD442reVtwo7. GVjwy6ARY-06kTghMiWxHstbAFghpMgUtk4bWOd_DW9uls2zVB1b 2-11-4 2x3 = 0-2-13 2-8-7 Scale = 1:11.0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC0.36 Vert(LL) 0.01 3-6 >999 360 MT20 2441190 TCDL 12.0 Lumber DOL 1.25 BC 0.41 Vert(CT) -0.01 3-6 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a rile BCDL 8.0 Code FBC2020rrP12014 Matrix -MP Weight: 9 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD 4-0-0 oc bracing. REACTIONS. (size) 1=0-8-0, 2=Mechanical, 3=Mechanical Max Horz 1=198(LC 4) Max Uplift 1=-155(LC 4). 2=21O(LC 4), 3=-41(LC 4) Max Grav 1=159(LC 9), 2=137(LC 9). 3=51(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., GCpj=0.18; C-C Exterior(2E); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck to the use of this truss component. 3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 4) Plates checked for a plus or minus 0 degree rotation about As center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. • ',j I I I I I lob 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. `�� P N V ♦♦♦ 0v E 7) Refer to girder(s) for truss to truss connections. , C [. ` '♦j G E /V 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 155 lb uplift at joint 1, 210 lb uplift at `�� , .'�\ joint 2 and 41 lb uplift at joint 3. No 68182 :X OF . UJ �. S Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/192020 BEFORE USE. Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417110 J40924 ZCJ5 Jack -Open 8 1 Job Reference o tional East Coast Truss, Ft. Pierce, FL - 34946, 8.430 s Mar 22 2021 MITek Industries, Inc. I MU Apr 1 Db:28:44 2U21 rage 1 ID:xfoRdl D442reVtwo7_GVjwy6ARY-06kTghMiWxHstbAFghpMgUtf7bSKd_DW9uls2zV B1 b Scale = 1:15.1 2x4 = 2-1 4-11-4 -2-1 4-8-7 Plate Offsets (X,Y)— [1:0-1-8,0-1-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.09 3-6 >669 360 MT20 244/190 TCDL 12.0 Lumber DOL 1.25 BC 0.67 Vert(CT) 0.07 3-6 >848 240 BCLL 0.0 Rep Stress [nor YES WB 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 8.0 Code FBC2020/TPI2014 Matrix -AS Weight: 16 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD 4-0-0 oc bracing. REACTIONS. (size) 1=0-8-0, 2=Mechanical, 3=Mechanical Max Horz 1=325(LC 5) Max Uplift 1=263(LC 4), 2=368(1_C 5), 3=-50(LC 5) Max Grav 1=270(LC 9), 2=240(LC 9), 3=83(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.Bpsf; h=17ft; Cat. Il; Exp D; Encl., GCpi=0.18; C-C Exterior(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 4-10-8; cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 4) Plates checked for a plus or minus 0 degree rotation about its center. j N �/ t 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' I Q F I� `�P 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. , .'�\ C' E N S''- • 7) Refer to girders) for truss to truss connections. `�� 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 263 lb uplift at joint 1, 368 lb uplift at 2 50 lb 3. No 68182 joint and uplift at joint * �� 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord. OF 44/ nn� Joaquin Velez PE No.68182 MITek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 A WARNING -Verify design parameters and - READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with Mi Tek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/f Quality Criteria, DSB-89 and SCSI Building Component 6904 Padre East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply Baron Island Storage T23417111 J40924 ZEJ6 Jack -Open 6 1 , Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 3x4 = 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 1 05:29:45 2021 Page 1 ID:xfoRdl D442reVtwo7_GVjwy6ARY-sJ Is21 MKHEPjUkISEOKbDhPoL?kaM REMIpeJPUzVB1 a 6-1-2 6-1-2 Scale = 1:18.4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) 0.16 3-6 >447 360 MT20 244/190 TCDL 12.0 Lumber DOL 1.25 BC 0.86 Vert(CT) -0.14 3-6 >525 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 2 n/a n/a BCDL 8.0 Code FBC20201TP12014 Matrix -AS Weight: 19 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 BOT CHORD 4-0-0 oc bracing. REACTIONS. (size) 1=0-8-0, 2=Mechanical, 3=Mechanical Max Horz 1=366(LC 5) Max Uplift 1=302(LC 4), 2=439(LC 5), 3=-42(LC 5) Max Grav 1=329(L'C 9), 2=297(LC 9), 3=100(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; VuR=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., GCpi=0.18; C-C Exterior(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 6-0-6; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 302 lb uplift at joint 1, 439 lb uplift at joint 2 and 42 lb uplift at joint 3. 9) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord. ,1�IIIIIII/I/ PGO IN No 68182 OF 441 �i� •• •.. R , • G? 'O N A, %%' "11Joaquin Velez PE No.68182 MIek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date. April 2,2021 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. �� Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417112 J40924 ZEJ6A Monapitch 4 1 Job Reference (optional) East Coast Truss, Ft. Fierce, FL - 34946, ts.4du s mar zz zuzl m1 I eK Inauslnes, Inc. I nu Apr i ua:.&a:40 Zuz I rage -I ID:xfoRdl D442reVtwo7_GVjwy6ARY-sJ Is21 MKHEPjUkISEOKbDhPn7?kTMREMIpeJPUzVB1 a 6-1-2 6-1-2 2x4 11 3x6 II 3x4 = Scale = 1:19.0 N-1 6-1-2 -1 5-10-5 Plate Offsets (X,Y)— [1:0-1-8 0-0-8j LOADING (pall) SPACING- 2-0-0 CSI. DEFL. in (cc) Vdefl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.85 Vert(LL) 0.16 3-6 >445 360 MT20 244/190 TCDL 12.0 Lumber DOL 1.25 BC 0.87 Vert(CT) -0.14 3-6 >517 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT)' -0.01 1 n/a . n/a BCDL 8.0 Code FBC2020/TP12014 Matrix -AS Weight: 23 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD 2x4 SP No.2 BOT CHORD 4-0-0 cc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 3=Mechanical Max Horz 1=353(LC 4) r Max Uplift 1=-302(LC 4), 3=461(LC 5) Max Grav 1=324(LC 9), 3=377(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-290/418 NOTES- 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.8psf; h=17ft; Cat. II; Exp D; Encl., GCpi=0.18; C-C Exterior(2E) -0-0-7 to 2-11-9, Interior(1) 2-11-9 to 5-11-6; cantileyer left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Plates checked for a plus or minus 0 degree rotation about its center. , ��� P . U N VF ♦� 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. , O Q ♦♦♦ 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. `� , _• �� G E N 5+1$1. ♦♦' 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 302 lb uplift at joint 1 and 461 lb uplift at No 68182 joint 3. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord. � ?3 S OF : �41J Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6534 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/192020 BEFORE USE. �� Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD,20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417113 J40924 ZHJ6 Diagonal Hip Girder 4 1 Job Reference (optional) East Coast Truss, Ft. Pierce, FL - 34946, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 1 05:29:46 2021 Page 1 ID:xfoRd1D442reVtwo7_GVjwy6ARY-KVsEFNNy2YXa6uKeo5sglvyxLP845ooW TNsxwzVB1Z 4-5-5 3x4 = 4-5-5 LOADING (psf) TCLL 20.0 TCDL 12.0 BCLL 0.0 BCDL 8.0 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 31 WEBS 2x4 SP No.3 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2020/TPI2014 REACTIONS. (size) 1=0-8-0, 6=Mechanical Max Horz 1=425(LC 5) Max Uplift 1=-789(LC 5), 6=871(LC 5) Max Grav 1=594(LC 15). 6=683(LC 16) CSI. DEFL. TC 0.95 Vert(LL) BC 0.59 Vert(CT) WB 0.43 Horz(CT) Matrix -MP FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-951/1090, 3-6=-240/338 BOT CHORD 1-7=1350/960, 6-7=-1350/960 WEBS 2-6=-1024/1439 BRACING - TOP CHORD BOT CHORD in (loc) I/defl L/d 0.05 6-7 >999 360 -0.05 6-7 >999 240 -0.01 6 n/a n/a 2x4 11 Scale = 1:19.0 3 4 PLATES GRIP MT20 244/190 Weight: 37 lb FT = 0% Structural wood sheathing directly applied or 5-10-0 oc purlins, except end verticals. 5-7-14 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=7.Opsf; BCDL=4.Bpsf; h=17ft; Cat. II; Exp D; Encl., GCpi=0.18; C-C Comer(3) -0-0-6 to 4-5-5, Exterior(2R) 4-5-5 to 8-6-11; cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 789 lb uplift at joint 1 and 871 lb uplift at joint 6. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 316 lb down and 237 lb up at 4-2-15, 316 lb down and 237 lb up at 4-2-15, and 387 lb down and 356 lb up at 7-0-14, and 387 lb down and 356 lb up at 7-0-14 on top chord, and 54 lb down and 110 lb up at 1-4-15, 54 lb down and 110 lb up at 1-4-15, 28 lb down and 39 lb up at 4-2-15, 28 lb down and 39 lb up at 4-2-15, and 50 lb down and 50 lb up at 7-0-14, and 50 lb down and 50 lb up at 7-0-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=64, 34=24, 5-8=16 ���>tuurr�i 4v IN `�� �O .•DENS ��i,�i No 68182 � r r ; G OF 4 ..� . �i,�••••. R Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 2,2021 —emtt;naed-orrpa _ WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 14II-7473 rev. 5/19/2,020 BEFORE USE. Design valid for use only with MTekS connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall n� //r� building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 'tll iTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply Baron Island Storage T23417113 J40924 ZHJ6 Diagonal Hip Girder 4 1 Job Reference o tional East Coast -I russ, Ft. Pierce, FL-34V46, 0.4OU 5 IVIar LL LUCI IVII r eK rr1UU5IIIe5, InG. I nu npr i uia—,o LUG i rage a ID:xfoRd1D442reVtwo7_GVjwy6ARY-KVsEFNNy2YXa6uKeo5sglvyxLP845ooW TNsxwzVB1Z LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 7=-29(F=-14, B=-14) 13=-106(F=-53, B=-53) 14=108(17=-54, B=-54) 15=-69(F=-34, B=-34) ®WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with Mirek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION 3/4' Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-11s' - -I- For 4 x 2 orientation, locate plates 0- Iris' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings — (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 dimensions shown In ft-in-sixteenths (Drawings not to scale) 1 2 3 TOP CHORDS C1-2 C2-3 o WEBS o" 4 O U �p� m d O n ~ c7-8 csa cs-s 00 BOTTOM CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See SCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or puriins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless'otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated. WARNING* ALL BEARING POINTS THIS IS A PLACEMENT PLAN FOR ENGINEERED BRACING: SEE FINAL ENGINEERING SHEETS FOR THE BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR UST BE INSTALLED PRIOR TO COMPONENTS AS DEFINED BY WTCA 1 - 1995. 1) FOR THE ERECTION BRACING FOLLOW STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS DESIGN DEPARTMENT APPROVES THEM IN ADVANCE DIAPHRAMS HAVE NOT BEEN ANALYZED BY INSTRUCTIONS ON THE BCSI-131 SUMMARY SHEETS PLIES AND THE CONNECTION INFORMATION. ALL HANGERS ARE SIMPSON STRONG -TIE OR USP INSTALLING ANY TRUSSES! FAILURE TO EAST COAST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE OUR DESIGN DEPARTMENT MUST APPROVE UNLESS OTHERWISE NOTED. INSTALL HANGERS O SO MAY RESULT IN DAMAGED TRUSSES AND WILL FOR ERECTION AND INSTALLATION OF TRUSSES FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY RESPONSIBILITY OF OTHERS. 3) INSTALL WEB BRACING AS STATED ON SEALED ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ACCORDING TO THE CURRENT SIMPSON STRONG -TIE OID ALL WARRANTIES. SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS IENGINEERING TRUSS DRAWINGS. ADVANCE. OR USP CATALOG 777 Indicates Lef t End Of Truss On Layout & Engineering Sheets HARDWARE: =HJC26 HANGERS (QTY. 4) TRUSS PLACEMENT PLAN RECEIVED JUL 19 2021 St, Lucie County Permitting ENGINEERED TIMBER TRUSS SYSTEMS PRODUCTS ECT EAST COAST TRUSS 5285 ST. LUCIE BLVD. FT. PIERCE, FL. 34946 OFFICE: (772) 466-2480 FAX: 47721466-5.4:36 STOMER:Benchmark III Corporation 3 NAME: Baron Island Storage DRESS:9500 South Ocean Dr. 'Y/COUNTY:Jensen Beach/Martin JOB # J40924 JOB # MODEL:Buildina E SQ FT 3203 ft2 DATE 01/04/21 LATEST=04/01/21 IN ACCORDANCE. WITH THE FLORIDA ADMINISTRATIVE .ODE (113155-31.003 L IV), EAST COAST TRUSS is the "Tru.us Design Engineer" Trusses arc designed in accordance with the Florida Building Cndc 17 •s NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the customer or his I representitive acknowledges that this placement plan i complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the project indicated on this drawing. The customer also acknowledges that he/she accepts financial responsibility for any repair, engineering, and _J labor required due to errors other than those of EAST Q COAST TRUSS. z Signed: Date: LL r) CODE = FBC 2020/TP12014 ASCE 7-16 - � W 0— DESIGN CRITERIA =C&C OCCUPANCY CATEGORY= II j pa�(`�® EXPOSURE = D MWF SPEED =165 < f BUILDING TYPE =ENCLOSED A MEAN HEIGHT: 17.00 ft i (n i GRAVITY LOADS W Z 1 I ROOF: DUR FACTOR= 1.25 (n PSF=TCLL-TCDL-BCLL-BCDL W 20.0,12.0,0.0,8.0 co LOADS PER FBC & FRC 'NON -CONCURRENT BC LL 10psf Z j CONCURRENT BC STORAGE LL 30 psf f— W U) DEFINITIONS MWF = MAIN WIND FORCE Q C&C = COMPONENTS AND CLADDING F— TOB = TOP OF BEARING TIC = TOP CHORD W BC = BOTTOM CHORD V) LL = LIVE LOAD DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT I-- # =POUNDS O z UPLIFT MUST BY-PASS FLOOR TRUSSES UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. O ALL GIRDER/COLUMN LOADS MUST 0 BY-PASS FLOOR TRUSS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. ; 2X6 STRONG BACK BRACING, 10'-0" O. C., IS > J RECOMMENDED ON FLOOR TRUSSES ^ SPANNING 20'-0" OR MORE O : AUTION: SPANS GREATER THAN 30'-0" RUST BE SET WITH A SPREADER BAR. THE U SPREADER BAR SHOULD BE AT LEAST 1/2 ro J 2/3 IN LENGTH AS THE SPAN OF THE TRUSS Q 3EING SET. \ / REFER TO BCI-B1 FOR COMPLETE O ERECTION AND SAFETY PROCEDURES. ALL BEAMS BY BUILDER NOTE. TRUSSES DO NOT SUPPORT ANY PLANT SHELVES REVISIONS 1. 3-22-2021 Revise Loading SB N 2. 4-1-2021 Revise Dbl. Truss To Single Truss 4- Over Unit Separation Wall SB O 3- 4- r 5- 6 (1/4" if plotted 24x36). Designed Bv- SR irm WARNING* ALL BEARING POINTS THIS IS A PLACEMENT PLAN FOR ENGINEERED BRACING: SEE FINAL ENGINEERING SHEETS FOR THE -BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR MUST BE INSTALLED PRIOR TO COMPONENTS AS DEFINED BY WTCA 1 - 1995. 1) FOR THE ERECTION BRACING FOLLOW STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS DESIGN DEPARTMENT APPROVES THEM IN ADVANCE DIAPHRAMS HAVE NOT BEEN ANALYZED BY INSTRUCTIONS ON THE BCSI-B1 SUMMARY SHEETS PLIES AND THE CONNECTION INFORMATION. ALL HANGERS ARE SIMPSON STRONG -TIE OR USP INSTALLING ANY TRUSSES! FAILURE TO EAST COAST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE OUR DESIGN DEPARTMENT MUST APPROVE UNLESS OTHERWISE NOTED. INSTALL HANGERS O SO MAY RESULT IN DAMAGED TRUSSES AND WILL FOR ERECTION AND 114STALLATION OF TRUSSES RESPONSIBILITY OF OTHERS. ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ACCORDING TO THE CURRENT SIMPSON STRONG -TIE OID ALL WARRANTIES. FOLLOW INSTRUCTICNS ON THE BCSI-131 SUMMARY 3) INSTALL WEB BRACING AS STATED ON SEALED ADVANCE, OR USP CATALOG SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS NGINEERING TRUSS DRAWINGS. 1 21 On 21 OII 21 OII 21 011 21 OII 21 OII 21 0" 21 OII 21 OII 21 OII 21 0" 2i OII 21 OII 21 OII 21 0" 156' 0" Z Z AC it v v F- t— Indicates Lef t End Of Truss On Layout & Engineering Sheets HARDWARE: =HJC26 HANGERS (QTY. 4) TRUSS PLACEMENT PLAN 21 a�Qew�a JUL 19 2021 St Lucie county Permitting 0® Ci®�$va GOAS-7 a No. 0471$2 1>-ii.�:iAtl ENGINEERED TRUSS SYSTEMS �� 0 ]EAST COAST T USS 5285 ST. LUCIE RIND. FT. FIERCE, FL 34946 OIFFTCE: 177D 466-2480 PAX; U72466-5336 :USTOMER:Benchmark III Corporation OB NAME: Baron Island Storage ,DDRESS:9500 South Ocean Dr. :ITY/COUNTY:Jensen Beach/Martin JOB # J40924 JOB # MODEL:Building E SQ FT 3203 ftz DATE 01/04/21 LATEST=04/01/21 IN ACCORDANCE WITH THE FLORIDA ADMINISTRATIVE CODE 61C15S-31.003 (3) (c), EAST COAST TRUSS is the T,u,, Dc,i,n Engineer" Trusses are designed in accordance with the Florida Building Code TIMBER PRODUCTS NOTE: n By approving this placement plan(s), signatured r anywhere on this sheet, the customer or his representitive acknowledges that this placement plan i complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the project indicated on this i drawing. The customer also acknowledges that he/she accepts financial responsibility for any repair, engineering, and J labor required due to errors other than those of EAST Q COAST TRUSS. Z Signed: Date: LL n CODE = FBC 2020/TP12014 ASCE 7-16 W DESIGN CRITERIA =C&C cc OCCUPANCY CATEGORY=11 G EXPOSURE = D < MWF SPEED =165 BUILDING TYPE =ENCLOSED MEAN HEIGHT: 17.00 ft U) U) GRAVITY LOADS _J Z ROOF: DUR FACTOR= 1.25 U) PSF=TCLL-TCDL-BCLL-BCDL W 20.0,12.0,0.0,8.0 (n U LOADS PER FBC & FRC *NON -CONCURRENT BC LL 10psf CONCURRENT BC STORAGE LL 30 psf I— W DEFINITIONS MWF = MAIN WIND FORCE O I{ C&C = COMPONENTS AND CLADDING TOB = TOP OF BEARING I TIC = TOP CHORD W -. BC = BOTTOM CHORD U) LL = LIVE LOAD DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT �— # =POUNDS O Z UPLIFT MUST BY-PASS FLOOR TRUSSES UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. O ALL GIRDER/COLUMN LOADS MUST 0 1 BY-PASS FLOOR TRUSS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. RECOMMENDED ON FLOOR TRUSSES SPANNING 20'-011 OR MORE UST BE SET WITH A SPREADER BAR. THE PREADER BAR SHOULD BE AT LEAST 1/2 0 '3 IN LENGTH AS THE SPAN OF THE TRUSS EING SET, EFER TO BCI-B1 FOR COMPLETE RECTION AND SAFETY PROCEDURES. SUPPORT ANY PLANT SHELVES 1. 3-22-2021 Revise Loading SB . 4-1-2021 Revise Dbl. Truss To Single Truss Over Unit Separation Wall SB 3- FILE COPY 4- 6- (1/4" if plotted 24x36) . Designed By: SB W n n