Loading...
HomeMy WebLinkAboutAPPROVED Engineer Ltr Williams M.A. CORSON & ASSOCIATES, Inc. ARCHITECTURE * STRUCTURAL DESIGN 412 Colorado Ave., Stuart, Fl. 34994 (772) 223-8227 * Lic. #AR91665 To: St. Lucie County - Building & Code Regulation Division Date: July 25, 2021 Re: Teresa Williams 9900 S. Ocean Drive / Oceana N. II /Unit 709 Jensen Beach, Fl. , 34957 It is acceptable to replace existing window, mullion bar and sliding glass door opening for the address listed above with the units as follows : 1) S.H. - The CGI Window & Doors Inc. - Sentinel Series "110” aluminum single hung Window has a Miami Dade NOA # 20-0722.09. It has a +80 /-85 design pressure. It has a small and large missile "D" approval HVHZ. 2) MULL BAR - The Series "Sentinel" Unclipped Mullion - L.M.I has a Miami Dade NOA # 20-0610.11. It has a +90.0 /-90.0 design pressure and has a large & small missile "D" approval and HVHZ . 3) FIBERGLASS DOOR. - The Jeld-Wen Design Pro / Smooth Pro impact glazed fiberglass door has a FL #16708.1 R13. It has a +65 /-65 design pressure and has a large missile "D" approval and HVHZ . 4) S.G.D. - The International Impact Building Products Series " Titan 90 " aluminum sliding glass door with reinforcements has a Miami Dade NOA # 20-1202.12. It has a +90 / -90 design pressure. It has a small and large missile "D" approval HVHZ. The worst case scenario building design pressures of addr ess listed above in Zone 4 is +58.7 / - 63.7 and Zone 5 is +58.7 / -78.5. The building has a type II classification and exposure category "D" for the 7th Edition of the FBC (2020). SCOPE OF WORK: New single hung window, mullion bar, & sliding glass door. DESIGN PARAMETERS AND ASSUMPTIONS USED: 1.DESIGN CODE: Florida Building Code Seventh Edition (2020) 2. Structure Designed: Enclosed 3. Risk Category: II Exposure Category: D 4. Design Wind Velocity 170 mph Nominal Wind Speed 132 mph End Zone Width: 4 ft 5. Mean Roof Height 153 ft Roof Pitch: 0:12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: Zone 4: +58.7 / -63.7 P.S.F. & Zone 5: +58.7 / -78.5 P.S.F. Worst case scenario has been calculated. 7. Design Loads: Floor: N/A Roof/Dead: N/A Roof/Live: N/A Balcony: N/A Dock: N/A Deck: N/A Stairs: N/A Fence: N/A Railings: N/A 8. Were Shear Walls Considered For Structure? N/A Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? N/A 10. Design Soil Bearing Pressure: N/A Soil Test Reports Submitted? N/A Thank you for your time and consideration. If you have any questions please call. Respectfully, Mark A Corson Mark A. Corson A.I.A., NCARB President Mark A Corson Digitally signed by Mark A Corson Date: 2021.07.26 00:01:17 -04'00'