Loading...
HomeMy WebLinkAboutAPPROVED, Kettler Sky Measure(1)Hammer Roofing 300 valley stream drive , Naples, FL Sales Representative: Johnny Auvil (772) 486-5685 Measurement Report Location Max Kettler 6735 Dickinson Terrace Port St. Lucie, FL 34952 Measurement Date: 07/08/2021 Measurement provided by Order #902249 SkyMeasure™ Residential Roof Measurement Report Page 1 Address:6735 DICKINSON TER, PORT ST LUCIE, FL 34952 Powered By AccuLynx 705 3rd St. Suite 380 Beloit Wisconsin 53511 US Order Information Claim Number 642241-GL Report Date 07/09/2021 Roof Dimensions (See notes below table) Total Number of Squares 37.30 Ridges 65 ft. Pitched Roof Area (Sq)37.16 Hips 132 ft. Flat Roof Area (Sq)*0.14 Valleys 111 ft. Primary Pitch 5 :12 Rakes 108 ft. Total Skylights 0 Eaves 183 ft. Total Chimneys 0 Rakes +Eaves 290 ft. Number of Facets 13 Apron Flashing 22 ft. Number of Structures on Report 1 Step Flashing 22 ft. Gutters 183 ft. * Flat roof area includes roof facets with 0:12, 1:12, and 2:12 pitches. View From Above Proximity view (roof at pin location) Order #902249SkyMeasure™ Residential Roof Measurement Report Property Photos - Oblique Page 2 View From North (01/06/2021) View From South (01/05/2021) View From East (01/06/2021) View From West (01/05/2021) Order #902249SkyMeasure™ Residential Roof Measurement Report Plan Diagram Page 3 To improve readability the lengths displayed in this diagram are rounded to the nearest whole number. Lengths under 4 feet are omitted for clarity. Facet Sq.Ft.Pitch Facet Sq.Ft.Pitch A 1087 5:12 H 70 5:12 B 692 5:12 I 51 5:12 C 673 5:12 J 47 5:12 D 371 5:12 K 44 5:12 E 296 5:12 L 37 5:12 F 195 5:12 M 14 2:12 G 158 5:12 AREA BY PITCH (in squares) 2 :12 5 :12 0.2 37.2 WASTE FACTOR TABLE (in squares,includes pitched and flat totals) 0%5%10%12%15%20% 37.3 39.2 41.1 41.8 42.9 44.8 The waste factors presented in the table are simple calculations based on the total area of the roof. They do not include any other roofing elements such as ridge, valley or hips. Use your best judgement and past experience to select the waste factor that works best for this particular roof. Order #902249SkyMeasure™ Residential Roof Measurement Report Enlarged Plan - Left Page 4 Order #902249SkyMeasure™ Residential Roof Measurement Report Enlarged Plan - Right Page 5 Order #902249SkyMeasure™ Residential Roof Measurement Report Property and Hazard Information Page 6 Property Information Latitude 27.3381596 Longitude -80.3286002 Garage Type ATTACHED GARAGE Weather Information Date of last hail event greater than 1.5”None Reported Date of last wind event greater than 55 MPH 11/05/2019 Florida Wind Ratings Florida Wind-Borne Debris Zone N/A High Velocity Hurricane Zone No Exposure Terain Category B High Velocity Hurricane Zone 1 N/A Wind speed cat 1 140 -149 mph High Velocity Hurricane Zone 2 N/A Wind speed cat 2 160 -169 mph High Velocity Hurricane Zone 3 N/A Wind speed cat 3 Healthcare 160 -169 mph High Velocity Hurricane Zone 4 N/A Wind speed cat 3 Non-Health 160 -169 mph Debris Zone 1 :Yes Wind speed cat 4 160 -169 mph Debris Zone 2 :Yes Debris Zone 3 Healthcare Yes Debris Zone 3 Non-Healthcare Yes Debris Zone 4 Yes Order #902249SkyMeasure™ Residential Roof Measurement Report Important Legal Notice and Disclaimer Page 7 This aerial measurement report is provided for informational purposes only and only for internal use by the initial purchaser/end-user recipient hereof, notwithstanding the foregoing, such purchaser/end-user may share this report with the owner of the property that is the subject of the report. Site conditions should be verified by physical inspection before purchasing materials or providing estimates to customers. This aerial measurement report is furnished “as is”, without warranty of any kind, express or implied, including but not limited to implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Some states do not allow the exclusion of implied warranties, so the above exclusions may not apply to customer. In that event, any implied warranties are limited in duration to ninety (90) days from the date of the report and to the dollar amount of the report. The contents of this report are protected by applicable copyright and other intellectual property laws and may include proprietary or other content of third persons. No permission is granted to copy, distribute, modify, post or frame any text, graphics, or user interface design or logos included in this report. All users of this report agree to hold harmless Corelogic and its affiliates, equity holders, directors, officers, employees, contractors, agents, representatives and suppliers of third-party content from any use or misuse, misapplication, alteration or unauthorized disclosure of this report. This notice and disclaimer is intended to function in harmony with the SkyMeasure™ report terms of use. In the event of any conflict between the two documents, the SkyMeasure™ report terms of use shall govern. This report was generated by SkyMeasure v7.06.0 on 07/09/2021.