Evaluation Report; Owens Corning Asphalt Roof Shingles
NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 to Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION.O. Owens Corning Evaluation Report 037940.02.12-1111 One Owens Corning Parkway FL10674-R16 Toledo, OH 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 11: 12/11/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. .OFsc ' PTION Owens Corniing Asphalt Roof Shinglss, LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPUANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. cT�'� The facsimile seal appearing was authorized by Robert '' -.' `c Nieminen, P.E. on 12/11/2020. This does not serve as an Florida Registration No. 59166, Florida DCA ANE1983 electronically signed document. CER'nRCA'nON of INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC, LLC *NEMO I etc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Ph Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Pro" e : Stantlartl Year 1507.2.4, R905,2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Material standard ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 Entl {Examinatlon Reference Date Owens Corning Declaration _. Equivalency Declaration 08/06/2019 PRI (TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 PRI (QUA9110) Quality Control Florida BCIS Current NEMO ETC, LLC Evaluation Report 037940.02.12-Ril Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-1116 Owens Coming Asphalt Roof Shingles Revision 12: 12/11/2020 Page 2 of 10 Berkshire" Hip and Ridge MN Shingles with Sealant Hip and DuraRidge® Hip and Ridge MN fiberglass reinforced, hip and ridge Ridge Shingles with Sealant ASTM D3462 Shmgles ProEdge® GA, CA, OH, OR asphalt roof shingles WeatherGuard° HP Hip and TN Ridge Shingles 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications - TABCE 2A WIND CLASSIFICATIONS, ASPHALT SHINGLES Supreme* Berkshire Duration' Premium Duration Premium COOL TruDefinition° Duration* ASTM D3161(F) & ASTM D7158(H) TruDefinition" Duration* Designer Color Collection Oakridge° TruDefinition° Oakridge° WeatherGuard° HP 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. MEMO ETC, LLC Evaluation Report 037940.02.12-R31 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-1116 Owens Corning Asphalt Roof Shingles Revision 22: 12/11/2020 Page 3 of 10 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION,: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ' . ; ` ACCE530RY STARTERS 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Felt underlayment —Deck Self -adhered WeatherLocka underlayment Drip Drip edge edge Nails located 2'-3"from eave Install first Self -searing adhesive Starter Strip positioned along eave shingle with 6"removed Starter Strip shingle overhangs eaves and rakes Wt ye Feb undedayment -Deck SelLadhered Weatherlotw, underlayment Dripedge °aip— e 9 Na1k located 2"-3"from cave WhlrestStarterStrip Pbs • " SosIllonedJonecave vmhVremoved P g Starter StMp Plus merhaegs caves and rakes i/4 -3/4' Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEIVIO ETC, LLC Evaluation Report 037940.02.12-Rll Certificate of Authorization #32455 7r" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Coming Asphalt Roof Shingles Revision 11:12/11/2020 Page 4 of 10 NNEMO I etc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. edge Starter Shingle Roll adhered directly to underlayment and primed drip edge Figure 3: Starter Shingle Roll 6 3 /�5PHALT SHINGLES _. _ 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuard` HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Normal Mansard or Area pare Wind Areas High Wind desvones V Area pare vientos normales Areas vientos fuertes '• (A) 5° Exposure Exposieion r�. z. (B 2. Figure 4: Minimum Nailing, Supreme (Standard Size) Normal Mansard or Area para Wind Areas High Wind deavanes y Area pore vientos normales Areas vientos fuertes ,z ,2 , 5 5/8• Exposure E rposieidn Figure 5: Minimum Nailing, Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.02.12-Rli Certificate of Authorization #32455 1TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 5 of 10 6.3.1.2 Berkshire®: Figure 6: 5-Nail Pattern, Berkshire ONEMO I etc. Sealant strip La t&a de sellador ' 8Y2 8W a 8%11 Figure 7: 6-Nail Pattern, Berkshire Figure 8: Mansard or Steep Slope Pattern, Berkshire MEMO ETC, LLC Evaluation Report 037940.02.12-1111 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Coming Asphalt Roof Shingles Revision 11: 12/11/2020 Page 6 of 20 ONEMOjetc. 6.3.1.3 Duration® Premium, TruDefinition® Duration, Duration® Premium COOL & TruDefinitione Duration" Designer Color Collection: 4-NAH. Fastening Patten SureNaHV, fast enin8ar"widtli Nail, Typical 1 IT, le 1" r e's 6918" e 18- Figure 9: Standard 4-Nail Pattern, Duration Figure 10: 6-Nail Pattern, Duration fastening for, Slopes Greater Tlian21'12 SureNali®.fastening area wlaih Nall; Typical 1 12" 12" 1" rt:,'.peens Cfnniap 5"re}LiY...�. c .� +�,!R'cNak:nwoy suimq r;.. -,;:� 4xnos CaiiinDSlaeNae�53�.� ' 77 L 5.518" exposure Four 1" Spots of Asphalt Roofing Cement. Figure 11: Mansard or Steep Slope Pattern, Duration NEMO ETC, LLC Evaluation Report 037940.02.12-Rll Certificate ojAuthorization #32455 1T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Coming Asphalt Roof Shingles Revision 11:12/11/2020 Page 7 of 10 6.3.1.4 TruDefinition'Oakridge". Oakridge": �corrxtclavos. tgrpa SF804- Figure 12: Standard 4-Nail Pattern, Oakridge IRNEMOjetc" Figure 13: 6-Nail Pattern, Oakridge Fastening for Sl000s:Greateffh4n 21:.12 S . ureNaH9 fastening aamwickh Nall 7ypleal 12" 12" .1. rt, 0 6.118. 12 Four I" Spoft of Asphalt Roofing Cerhent 6.3.1.5 WeatherGuard® HP: 6 Nal Pattern Esquerna con 6 clavos Nail 6 118" from bottom of shingle Clove a 6 11 ulg. de la 5 518' Exposure 6 Fasteners parte inferior de li too Exposicion de 5 518 pulg. 6 sujotadores UPI; 125g. 10, ---aro 5 0, Enos" 5 W, EMS= Four 1" Spots of Asphalt Roof Cement EvoskAh do 5 52 pv4 Eqoskldn 63 5 Yspiq Coatropuntos do ceirrento de techo do as/alto de I pukada Figure 15: 6-Nail Pattern, WeatherGuard HP Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP NEMO ETC, LLC Evaluation Report 037940.02.12-RII Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-RI6 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 8 of 10 ➢ Berkshire° Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require minimum two (2) nails per shingle. ➢ WeatherGuard* HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire® Hip and Ridge with Sealant and DuraRldgeO Fair, and Ridge Shingles with Sealant: Fig. A Prevailing Wind Direction �— Direcci6n del viento predominante Nails " Clavos \ I I 4 I I A I I I I I I I I I I I I I �--S"Fxposur IEiposicihde809 4 A Figure 17: Isometric View, Berkshire and DuraRidge 6.4.1.2 WeatherGuard® HP Hip and Ridge Shingles: Fig: A Prevalli� Wlnd Dlrection Figure 19: Isometric View, WeatherGuard HP Hip and Ridge i-igure its: Tian View, tierKsnire ana LJUraRlage Fig. AP &:Ritlge` hih '10aster ing: TopView, NaIIs Halls Exposure Figure 20: Plan View, WeatherGuard HP Hip and Ridge NEMO ETC, LLC Evaluation Report 037940.02.12-Rll Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Coming Asphalt Roof Shingles Revision 12:12/11/2020 Page 9 of 10 6.4.1.3 ProEdeeO: Prevailing Wind Direction Sedent strip A*----r 6" Exposure Cover Exposed Fasteners with Roof Cement _ Figure 21: Isometric View, ProEdge ONEMOjetc. Standard--11"—y Fastening Pattern 12° Sealant a° 7 6' Exposure IF-12° li—� Figure 22: Plan View, ProEdge As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 614320-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777; bwilson(@Pricmt.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 037940.02.12-1131 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116 Owens Coming Asphalt Roof Shingles Revision 11:12/11/2020 Page 10 of 10