HomeMy WebLinkAboutCORNER KING JACK CONNECTIONJANUARY 20, 2021 TYPICAL HIP/ KING JACK CONNECTION CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. / / / Attach End J ck's / w/ (4) 16d Toe ails@ TC & (3) 16d Toe ails@ BC X <( � 0 0 I 0 0 I r-- --------._ Chambers Truss, Inc. ·3105 Oleander Ave. Ft. Pierce Fl. 34982 Ph: 772-465-2012 --------._ --------._ Attach King Jack w/ (3) 16d Toe Nails@ TC & BC STDTL THIS SEAL & ELECTRONIC SIGNATURE CERTIFIES ALL (2) SHEETS IN THIS FILE JANUARY 20, 2021 TYPICAL HIP/ KING JACK CONNECTION STDTL HVHZ CORNERSET SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. / / _j -._____ Attach King and End Jack - Attach King & End Jack's w/ (1) LSTA 12 wist Strap (10)10d Nails in. Per Stra 16d To Nails � � 0 0 I 0 0 I f'-,.. NOTE: IN TOENAIL JACKS T THE FOL 2x4: (2) 1 2x6: (3) 1 TC w/ (3) DDITION TO S TH CHORDS ARRYING ME WING SCHED Toe Nails Toe Nails w/ (1) THJA26 or Equivalent Hanger on BC "-::::!:%:::=�::: � Attach Corner Jack's an }!f§fa: � Standard Jacks w/ (1) L .[�f. APPING F CORNER BER PER E. Twist Strap @ TC & BC {ffijl w/ (10) 10d Nails Min. P .--��Sir. p ?f;.@;;; LSTA12 TWIST STRAP W/ MIN. (10) 100 NAILS (SEE MANUFACTURER'S RECOMMENDED CONNECTION) JACK/CORNER JACK (TYP.)-- NOTE: CONNECTION DESIGNED IN ACCORDANCE WITH FBC 2321.6-2321.7 PROVIDING METAL STRAPPING (FLORIDA APPROVED PRODUCT) TO RESIST MIN. 700LB UPLIFT AT ALL CONNECTIONS IN HVHZ Chambers Truss, Inc. 3105 Oleander Ave. Ft. Pierce Fl. 34982 Ph: 772-465-2012 --�----�p OR KING JACK (TYP.) 02/22/2021