Loading...
HomeMy WebLinkAboutWeathermaster 200 peel n stick CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 Ij TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020) Manufacturer: ATLAS ROOFING CORPORATION Issued October 16, 2020 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770)612-6267 www.atlasroofing.com Quality Assurance: PRI Construction Materials Technologies, LLC(QUA9110) SCOPE Category: Roofing Subcategory: Underlayments Code Edition: Florida Building Code, 71" Edition (2017)including High-Velocity Hurricane Zones (HVHZ) Code Sections: 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) ATL-033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies(TST6049) ATL-068-02-01 ASTM D 1970 2015a ASTM D 4798 2011(2016) TAS 110 2000 PRI Construction Materials Technologies(TST6049) ATL-069-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) ATL-149-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) ATL-164-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) ATL-254-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) ATL-255-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) BWR-534-02-01 ASTM D 1970 2015a ASTM D 4798 2011(2016) TAS 110 2000 PRI Construction Materials Technologies(TST6049) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST6049) MSA-026-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) WRMI-011-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST6049) MSA-026-02-01.1 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-030-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-047-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-054-02-01.1 TAS 103 2020 TAS 110 2000 PRI Construction Materials Technologies(TST6049) MSA-057-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST6049) MSA-062-02-01.1 ASTM D 1623 2017 PRI Construction Materials Technologies(TST6049) 1085T0002 TAS 110 2000 PRI Construction Materials Technologies(TST6049) 1085T0007 ASTM D 1623 2017 PRI Construction Materials Technologies(TST6049) 117T0001 ASTM D 1623 2017 PRI Construction Materials Technologies(TST6049) 117T0004 TAS 110 2000 PRI Construction Materials Technologies(TST6049) 117T0005 UL 1897 2012 PRI Construction Materials Technologies(TST6049) 1085T0011 ASTM D 1623 2017 TAS 103 2020 UL LLC(TST1740) 02-NK40952 ASTM D 1970 2015a UL LLC(TST1740) 02-NK40952 ASTM D 226 2009 UL LLC(TST1740) 02-NK40952 ASTM D 2626 2004(2012)E1 UL LLC(TST1740) 02-NK40952 ASTM D 4869 2016 UL LLC(TST1740) 02-NK40952 ASTM D 6380 2003(2013)E1 ATL14001.7A FL17322-R7 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK ATLAS ROOFING CORPORATION Roofing Underlayments TECHNICAL SERVICES, L.LC PRODUCT DESCRIPTION #15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the HVHZ. #30 Organic Saturated Felt ASTM D 4869, Type 11 asphalt saturated organic felt underlayment for use in the non-HVHZ only. #30 Specification Felt ASTM D 226, Type II asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #43 Base Sheet ASTM D 2626 asphalt saturated and coated, non-perforated, organic felt underlayment for use in the HVHZ and non-HVHZ. #90 Mineral Surface Roll ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the Roofing HVHZ and non-HVHZ. Gorilla Guard®EVERFELT 30 Asphalt-saturated organic felt underlayment reinforced with glass fiber that meets the performance requirements of ASTM D 226, Type I for use in the HVHZ. Slate/Tile Underlayment ASTM D 6380, Class M asphalt-saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. WeatherMaster®Ice and ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a Water 100 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster®Ice and ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a Water 200 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film, which is removed during installation. WeatherMaster®Ice and ASTM D 1970 SBS modified, self-adhering underlayment reinforced with a Water 216 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film, which is removed during installation. WeatherMaster®Flexible Ice ASTM D 1970 SBS modified, self-adhering underlayment with plastic film surface and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split-release film,which is removed during installation. WeatherMaster®Pro-Grade ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Ice and Water Tile Installation Manual, Sixth Edition compliant compliant SBS modified, self- adhering underlayment with a fiberglass mat reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film,which is removed during installation. WeatherMaster®Tile ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant compliant SBS modified, self- adhering underlayment with a fiberglass mat reinforcement and a poly-fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film,which is removed during installation. ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK ATLAS ROOFING CORPORATION Roofing Underlayments TECHNICAL SERVICES, L.LC APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Exposure of the underlayments shall be limited to a maximum 30 days except as follows: a) #15 Specification Felt,#30 Specification Felt, and#40 Base Sheet—exposure for greater than 24 hours may adversely affect product performance b) WeatherMaster® Ice and Water 100, WeatherMaster® Ice and Water 200, WeatherMaster® Ice and Water 216—maximum 45 days c) WeatherMaster®Pro-Grade Ice and Water—maximum 180 days d) WeatherMaster® Tile—maximum 180 days Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as indicated in other current FBC product approval documents): a) WeatherMaster® Pro-Grade Ice and Water— DAP Touch `n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond b) WeatherMaster®Tile—DAP Touch `n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond Allowable Roof Coverings: Composite Metal Roof or Wood Clay and Asphalt Panels and Photovoltaic Shingles Slate Concrete Underlayment Shingles Shingles Shingles and Shakes Shingles Tile #15 Specification Felt(HVHZ Y Y N YZ Y N only) #30 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y #43 Base Sheet Y Y Y N Y Y #90 Mineral Surface Roll Y1 N N N N Y Roofing Gorilla Guard®EVERFELT 30 Y Y Y Yz Y N Slate/Tile Underlayment Y1 N N N N Y WeatherMaster®Ice and Y Y Y N Y N Water 100 WeatherMaster®Ice and Y Y Y N Y N Water 200 WeatherMaster®Ice and Y Y Y N Y N Water 216 WeatherMaster®Flexible Ice Y Y Y N Y N and Water WeatherMaster®Pro-Grade Y Y Y N Y Y Ice and Water WeatherMaster®Tile Y Y Y N Y Y Notes: 1)Open valley applications per 1507.2.9.2 2)Wood shingles only ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK ATLAS ROOFING CORPORATION Roofing Underlayments TECHNICAL SERVICES, L.LC WIND RESISTANCE(NON-HVHZ ONLY) The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 —WeatherMaster®Tile only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: WeatherMaster®Tile shall be fully adhered to the optionally primed plywood deck. Maximum Design -52.5 psf Pressure: Underlavment System No.2—WeatherMaster®Pro-Grade Ice and Water only Roof Deck: Min. 15/32-inch APA plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: WeatherMaster® Pro-Grade Ice and Water shall be backnailed 12-inches o.c. to the plywood deck using min. 12ga, 1-1/4" galvanized, ring shank roofing nails with min. 32ga 1-5/8"diameter tin caps. Maximum Design -105 psf Pressure: LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Roof slope limitations shall be in accordance with FBC requirements. 3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Products described within this report may be used as described in other current FBC product approval documents. 5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other current FBC product approval documents. 6) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 0 CREEK ATLAS ROOFING CORPORATION Roofing Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 7`h Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. 2020. 10. 16 No 74021 14: 18:26 -0400' 3 STATE OF :�44/� '��'� '•:c< p Q:••���`� Zachary R. Priest, P.E. R \• G�`� Florida Registration No. 74021 'fl,0NA'�'.0 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.