Loading...
HomeMy WebLinkAboutAPPROVED Off Ridge Vent (9)(1)1/22/21, 9:58 AMFlorida Building Code Online Page 1 of 2https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvBwYu9TrZNm4u1qD3EaihUyA3HWjfCFjF%2frNZE9g0nyQ%3d%3d BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL16994-R6 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Southeastern Metals Mfg. Co. Address/Phone/Email 11801 Industry Drive Jacksonville, FL 32218 (904) 696-4682 jhkelsey@semetals.com Authorized Signature Jeremy Kelsey jhkelsey@semetals.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/20/2023 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL16994_R6_COI_SEM14001.6a 2020 FBC Eval Off-Ridge Vent final.pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By 1/22/21, 9:58 AMFlorida Building Code Online Page 2 of 2https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvBwYu9TrZNm4u1qD3EaihUyA3HWjfCFjF%2frNZE9g0nyQ%3d%3d Sections from the Code 1503.5 1709.2 Product Approval Method Method 2 Option B Date Submitted 08/11/2020 Date Validated 09/01/2020 Date Pending FBC Approval 09/20/2020 Date Approved 12/15/2020 Date Revised 12/17/2020 Summary of Products FL #Model, Number or Name Description 16994.1 Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with asphalt shingles Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-18 Other: See evaluation report for limits of use. Installation Instructions FL16994_R6_II_SEM14001.6a 2020 FBC Eval Off-Ridge Vent final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL16994_R6_AE_SEM14001.6a 2020 FBC Eval Off-Ridge Vent final.pdf Created by Independent Third Party: Yes 16994.2 Tile Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with clay or concrete tile Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-9 Other: See Evaluation Report for limits of use. Installation Instructions FL16994_R6_II_SEM14001.6b 2020 FBC Eval Tile Roof Vent final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL16994_R6_AE_SEM14001.6b 2020 FBC Eval Tile Roof Vent final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a CREEK SEM14001.6a FL16994-R6 Page 1 of 3 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: Southeastern Metals Manufacturing Co., Inc. (SEMCO) Issued August 11, 2020 11801 Industry Drive Jacksonville, FL 32218 (800) 874-0335 http://www.semetals.com Manufacturing Plant: Jacksonville, FL Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1503.5, 1709.2 Properties: Roof Ventilation REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) SEM-029-02-01 ASTM E 330 2014 PRI Construction Materials Technologies (TST5878) SEM-031-02-01 ASTM E 330 2014 Zachary R. Priest, P.E. (CREEK Technical Services) SEM14003 Calculations 2014 PRODUCT DESCRIPTION Off Ridge Vent: Minimum 26 ga. ASTM A792 or ASTM A653 CS Type B steel; Shall conform with FBC Section 1503.2 Maximum dimensions of the vent are 24-inch wide x 102-inch long x 4.25-inch high. Vent is available in nominal 4-ft, 6-ft and 8-ft sizes. a CREEK Technical Services, LLC SEM14001.6a FL16994-R6 Page 2 of 3 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Southeastern Metals Manufacturing Co., Inc. Off Ridge Vent PRODUCT APPLICATION Deck Type: Minimum 7/16-inch APA span rated OSB sheathing or 15/32-inch APA span rated plywood sheathing for new and existing roof deck (Deck shall be designed by others in accordance with FBC requirements). Roof slope: Minimum 2:12 Installation Height: Maximum 33-ft Roof Cut-Out: 2.5-inch wide x 42-inch opening for the nominal 4-ft vent 2.5-inch wide x 66-inch opening for the nominal 6-ft vent 2.5-inch wide x 90-inch opening for the nominal 8-ft vent Attachment Method: Cut-out opening as prescribed above into the sheathing located a minimum 6-inch off the ridge. For a single vent, install the vent as close to the center of the roof length as possible. Multiple vents should be evenly spaced along the roof length. Remove interfering shingle nails around the perimeter of the opening and any debris prior to placing vent. Apply ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic to the underside of the perimeter flange to continuously surround and seal the flange. Position the vent over the opening in the roof sheathing. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with #9 x min. 1.5-inch HWH screws with 0.5-inch sealing washers or min. 12 ga. x 1- 1/4-inch ring shank nails with min. 3/8-inch diameter heads having sufficient length to penetrate through the sheathing a minimum of 3/8-inch. The fasteners shall be located 1- inch from the edge of the flange and 5.5-inches o.c. along all four sides of the vent. All loosened shingles shall be adhered down with roof cement/mastic. When nails are used to attach the vent, all penetrations through the vent flange shall be sealed using ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic. Allowable Roof Coverings: Asphalt shingles Maximum Design Pressure -13.5 psf for 4-ft and 6-ft vents -18 psf for 8-ft vent Pressures calculated using 2:1 margin of safety per 1504.9 a CREEK Technical Services, LLC SEM14001.6a FL16994-R6 Page 3 of 3 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co., Inc. Off Ridge Vent LIMITATIONS 1)This report is not for use in the HVHZ. 2)Fire Classification is outside the scope of this evaluation. 3)The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4)SEMCO vents shall be insWalled in sWricW compliance ZiWh Whis eYalXaWion reporW and Whe manXfacWXrer¶s published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5)Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6)Installation of the roof assembly is outside the scope of this evaluation. 7)SEMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications 8)All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT 2020.08.11 14:22:55 -04'00'