Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, Flintlastic Flat NOA (19)(1)
1/21/21, 10:24 AMFlorida Building Code Online Page 1 of 2https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvweIwRFXRvHOHSbalV%2f8EtEwKml7TNAMmEePdWFs1K%2bg%3d%3d BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL2533-R24 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer CertainTeed, LLC (Roofing) Address/Phone/Email 20 Moores Road Malvern, PA 19355 (610) 893-5400 mark.d.harner@saint-gobain.com Authorized Signature Mark Harner mark.d.harner@saint-gobain.com Technical Representative Mark D. Harner Address/Phone/Email 18 Moores Road Malvern, PA 19355 (610) 651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/15/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL2533_R24_COI_2020_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2015 ASTM D2178 2015 1/21/21, 10:24 AMFlorida Building Code Online Page 2 of 2https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvweIwRFXRvHOHSbalV%2f8EtEwKml7TNAMmEePdWFs1K%2bg%3d%3d ASTM D4601 2012 ASTM D4897 2009 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 ASTM G155 2013 FM 4470 2016 FM 4474 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/30/2020 Date Validated 08/04/2020 Date Pending FBC Approval 08/08/2020 Date Approved 10/13/2020 Summary of Products FL #Model, Number or Name Description 2533.1 Flintlastic Modified Bitumen Roof Systems Modified Bitumen Roof Systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-635 Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure noted in this application relates to one specific system. Refer to the ER Appendix for all systems and max design pressures. Installation Instructions FL2533_R24_II_2020_07_20_FINAL_A1_ER_CERTAINTEED_MODBIT_FL2533- R24.pdf Verified By: Robert Nieminen, PE PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2533_R24_AE_2020_07_20_FINAL_ER_CERTAINTEED_MODBIT_FL2533- R24.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 07/20/2020 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 1 of 74 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-8 1C Wood New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 8 1D Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9-10 1E Wood New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 11-13 1F-1 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-16 1F-2 Wood New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-18 1G Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18 2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-21 2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22-26 2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 27-29 3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 30-39 3B Structural concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 40 3C Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 40 4A LWIC / steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 4B LWIC / structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 43-46 4C LWIC / structural concrete New, Reroof (Tear-Off) A-1 Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 47-48 4D LWIC / steel New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 49-51 4E LWIC / steel or struct. conc. New or Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 52-57 4F LWIC / steel Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 57 4G LWIC / steel Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 58 5A Cementitious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 59 5B Cementitious wood fiber New or Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 60 5C Cementitious wood fiber Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 61 5D Cementitious wood fiber New, Reroof (Tear-Off) or Recover E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 61 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 62-64 6B Existing gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 64-65 6C Existing gypsum Reroof (Tear-Off) C Mech. Attached Insulation, Bonded Roof Cover 65 6D Existing gypsum Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 66 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 67-74 7B Various Recover F Non-Insulated, Bonded Roof Cover 74 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 07/20/2020 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 2 of 74 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ¾ Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate, Dekfast #1ϰ ǁiƚh Hedž Plaƚe oƌ ϯ͟ RoƵnd InƐƵlaƚion Plaƚe͕ Trufast HD with TƌƵfaƐƚ ϯ͟ Metal Insulation Plates oƌ FlinƚFaƐƚ ηϭϰ FaƐƚeneƌ ǁiƚh FlinƚFaƐƚ ϯ͟ InƐƵlaƚion PlaƚeƐ. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ¾ Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plaƚe͕ DekfaƐƚ ηϭϮ oƌ ηϭϰ ǁiƚh Hedž Plaƚe oƌ ϯ͟ RoƵnd Insulation Plate, Trufast DP or HD with TƌƵfaƐƚ ϯ͟ Meƚal InƐƵlaƚion PlaƚeƐ or FlinƚFaƐƚ ηϭϮ oƌ ηϭϰ FaƐƚeneƌ ǁiƚh FlinƚFaƐƚ ϯ͟ InƐƵlaƚion PlaƚeƐ. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ¾ Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plaƚe͕ DekfaƐƚ ηϭϰ oƌ DekSpike ǁiƚh Hedž Plaƚe oƌ ϯ͟ RoƵnd InƐƵlaƚion Plate, Trufast HD or CF with TƌƵfaƐƚ ϯ͟ Meƚal InƐƵlaƚion PlaƚeƐ oƌ FlinƚFaƐƚ ηϭϰ FaƐƚeneƌ ǁiƚh FlinƚFaƐƚ ϯ͟ InƐƵlaƚion PlaƚeƐ. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accoƌdance ǁiƚh ƚhe faƐƚeneƌ manƵfacƚƵƌeƌ͛Ɛ pƵbliƐhed inƐƚallaƚion inƐƚƌƵcƚionƐ. 3. Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B, C or D, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noƚed in ƚhe manƵfacƚƵƌeƌ͛Ɛ pƵbliƐhed inƐƚƌƵcƚionƐ͘ ¾ Hot asphalt (HA): Full coverage at 25-30 lbs/square ¾ Ashland, Inc. ͞Pliodeck InƐƵlaƚion AdheƐiǀe͟ (A-PD): Continuous 0.75 inch wide ribbons, 12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below. ¾ Dupont ͞INSTA STIK Quik Set Commercial Roofing Adhesive͟ (D-IS): Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c. ¾ ICP Adhesives and Sealants ͞Polyset BOARD-MAX͟: Continuous 3-inch ribbons, 12-inch o.c. ¾ ICP Adhesives and Sealants ͞Polyset CR-20͟: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. ¾ HB FƵlleƌ ͞Millennium One Step Foamable Adhesive͟ (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ¾ HB FƵlleƌ ͞Millennium PG-1 Pump Grade Adhesive͟ (M-PG1): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. ¾ OMG OlyBond 500 or OlyBond Green (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart, SpotShot or Canister) ¾ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, boards shall be staggered from layer-to-layer. ¾ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations͘ In no caƐe Ɛhall ƚheƐe ǀalƵeƐ be ƵƐed ƚo ͚incƌeaƐe͛ ƚhe MDP liƐƚingƐ in ƚhe ƚableƐ͖ ƌaƚheƌ if MDP liƐƚing beloǁ meeƚƐ oƌ exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ¾ Ashland, Inc. ͞Pliodeck InƐƵlaƚion AdheƐiǀe͟ (A-PD) @ 12-inch o.c. MDP -105.0 psf (Min. 1.0-inch) ¾ Ashland, Inc. ͞Pliodeck InƐƵlaƚion AdheƐiǀe͟ (A-PD) @ 6-inch o.c. MDP -277.5 psf (Min. 1.0-inch) ¾ Dupont ͞INSTA STIK Quik Set Commercial Roofing Adhesive͟ (D-IS): MDP -120.0 psf (Min. 1.0-inch) ¾ ICP Adhesives and Sealants ͞Polyset CR-20͟: MDP -117.5 psf (Min. 1.0-inch) ¾ HB FƵlleƌ ͞Millennium One Step Foamable Adhesive͟ (M-OSFA): MDP -157.5 psf (Min. 1.0-inch) ¾ HB FƵlleƌ ͞Millennium PG-1 Pump Grade Adhesive͟ (M-PG1): MDP -157.5 psf (Min. 1.0-inch) ¾ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch Multi-Max FA3) ¾ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch ISO 95+ GL) ¾ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch ENRGY 3) ¾ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch ACFoam II) 8. For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 07/20/2020 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 3 of 74 9. For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type D, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14. Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1͘ Foƌ ͞pƌe-existenƚ͟ LWIC ƌefeƌenceƐ͕ liƐƚingƐ ǁeƌe eƐƚabliƐhed ƚhƌoƵgh ƚeƐƚing oǀeƌ lighƚǁeighƚ concƌeƚe caƐƚ using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted, refer to the following references for bonded applications. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-CA1 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base FlintBond Brush or Karnak No. 81 Cold Process Modified Bitumen Adhesive Brush Grade at 1 gal/square Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar BP-CA2 Base Ply: Glasbase, All Weather/Empire Base, Flexiglas Base, Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square. SBS-CA2 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar BP-CA3 Base Ply: Glasbase, All Weather/Empire Base, Flexiglas Base, Flintlastic Base 20 Millennium Hurricane Force Membrane Adhesive, beads spaced 6-inch o.c. SBS-CA3 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 07/20/2020 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 4 of 74 MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-AA Base Ply: Glasbase, All Weather/Empire Base, Flexiglas Base, Flintlastic Base 20 hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4, Flintglas Premium Ply 6 BP-AA2 Base Ply: Yosemite Venting Base hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Yosemite Venting Base hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Yosemite Venting Base hot asphalt in 9-inch wide ribbons spaced as noted herein. SBS-AA Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar SBS-TA Base Ply: Flintlastic Ultra Poly SMS Base, Flintlastic Base 20 T torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base, Flintlastic Base 20 T Cap Ply: Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, Flintlastic GTS-FR, Flintlastic GTS-FR CoolStar APP-TA Base Ply: One or more Flintlastic APP Base T, Flintlastic STA, Flintlastic STA Plus torch-applied Cap Ply: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar SBS-SA-H Base Ply: Black Diamond Base Sheet, Flintlastic Ultra Glass SA self-adhering (activated by overlying membrane) SBS-SA Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply self-adhering Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar 16. Vapor barrier options for use over structural concrete deck followed by adhesive-applied insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies: VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION PER TABLE 3A, (The lesser of the MDP listings below vs. those in Table 3A applies) OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE ATTACH VB-1. FlintPrime Flintlastic SA PlyBase Self-adhering OB500, 12-inch o.c. -82.5 VB-2. None All Weather / Empire Base Sheet; 3-inch wide side laps and 6-inch wide end laps are sealed with Millennium Hurricane Force Lap and Flashing Adhesive Millennium Hurricane Force Membrane Adhesive, max. 6-inch o.c. M-OSFA or M-PG1, 12-inch o.c. -82.5 VB-3. None Flintlastic Ultra Poly SMS Base Sheet; 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with Millennium Hurricane Force Lap and Flashing Adhesive Millennium Hurricane Force Membrane Adhesive, max. 6-inch o.c. M-OSFA or M-PG1, 12-inch o.c. -82.5 VB-4. FlintPrime or FlintPrime SA Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 12-inch o.c. -97.5 VB-5. FlintPrime or FlintPrime SA Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1, 6-inch o.c. -315.0 VB-6. FlintPrime Flintlastic GTA Torch-applied M-OSFA or M-PG1, 12-inch o.c. -420.0 VB-7. FlintPrime Flintlastic Base 20 T or Flintlastic FR Cap 30 T Torch-applied M-OSFA or M-PG1, 12-inch o.c. -495.0 17. ͟MDP͟ с MadžimƵm DeƐign PƌeƐƐƵƌe iƐ ƚhe ƌeƐƵlƚ of ƚeƐƚing foƌ ǁind load ƌeƐiƐƚance baƐed on alloǁable ǁind loadƐ͘ Refeƌ ƚo FBC 1609 for determination of design wind loads. NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R24 for FL2533-R24 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 07/20/2020 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 18 of 74 TABLE 1F-2: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-100 Min. 19/32-inch plywood; 24-inch span Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Venting Base Note 2 7-inch o.c. at 3-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 W-101 Min. 19/32-inch plywood; 24-inch span Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD or Dekfast Hex Plate with Dekfast #14 7-inch o.c. at 3-inch lap and 7-inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-102 Min. 15/32-inch plywood; 24-inch span Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Venting Base FlintFast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Meƚal InƐƵlaƚion PlaƚeƐ with DP or HD; OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -127.5 W-103 Min. 15/32-inch plywood; 24-inch span Flintlastic APP Base T OMG 3 in. Round Metal Plates with OMG #14 HD 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-104 Min. 15/32-inch plywood; 24-inch span Glasbase; Flexiglas Base; Flintlastic Base 20; All Weather / Empire Base; Yosemite Venting Base; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base FlintFast 3 in. Insulation Plates with FlintFast #12 or #14; Trufast ϯ͟ Meƚal InƐƵlaƚion PlaƚeƐ with DP or HD 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply W-105 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing; 24-inch span FlintPrime or FlintPrime SA Flintlastic SA Mid Ply, self-adhering (Optional) SBS-SA SBS-SA -90.0 W-106 Min. 15/32-inch plywood; 24-inch span FlintPrime or FlintPrime SA SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5 W-107 Min. 15/32-inch plywood; 24-inch span FlintPrime or FlintPrime SA SBS-SA (Optional) SBS-SA SBS-SA -127.5