HomeMy WebLinkAboutCarlisle-WIP-FBC-Approvals_FL6785-R9NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
0 (203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Carlisle Coatings & Waterproofing Evaluation Report C39180.12.11-R5
900 Hensley Lane FL6785-R9
Wylie, TX 75098 Date of Issuance: 12/09/2011
(717) 245-7000 Revision 5: 06/17/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have evaluated for compliance with the 61' Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: CCW Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
.`70,;"
�S1
Robert J.M. Nieminen P.E.
''> = �; o-r,>•:
The facsimile seal appearing was authorized
Florida Registration No. 59166, Florida DCA ANE1983
Ei.,'.; ',; ,`0``
by Robert Nieminen, P.E. on 06/17/2019
This does not serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOletc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOletc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
ONEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing, have
demonstrated compliance with the following sections of the 6t" Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
Section
Property
Standard
Year
1507.1.1, T1507.1.1, 1507.2.9.2, Physical Properties
ASTM D1970
2015
R905.1.1, TR905.1.1, R905.2.8.2
1507.3.3, R905.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
TAS 110
Accelerated Weathering
ASTM D4798
2011
Entity
Examination
Reference
Date
ERD (TST6049)
ASTM D1970 (TX)
C41280.10.12
10/05/2012
MTI (TST2508)
ASTM D1970 (PA)
PX02MOA
01/17/2011
MTI (TST2508)
ASTM D1970 (PA)
PX13MOB
01/18/2011
ICC-ES (EVL2396)
2015 IBC/IRC Compliance
ESR-1556
02/01/2018
ICC-ES (EVL2396)
2015 IBC/IRC Compliance
ESR-2206
06/01/2018
NEMO (TST6049)
FRSA/TRI April 2012 (04-12) (PA&TX)
4S-CRL-18-004.12.18-1
12/17/2018
NEMO (TST6049)
ASTM D1970 (adhesion) (TX)
4S-CRL-18-004
01/21/2019
NEMO (TST6049)
ASTM D1970 & D4798 (PA)
4j-CRL-I9-SSUDL-03.A
05/28/2019
NEMO (TST6049)
ASTM D1970 (PA)
4j-CRL-I9-SSUDL-02.A
06/03/2019
NEMO (TST6049)
ASTM D1970 & FRSA/TRI (04-12) (TX)
4S-CRL-18-004.06.19.A
06/12/2019
UL, LLC. (QUA9625)
Quality Control
TGDY.R18678 Listing
10/18/2010
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
04/13/2017
Product
4.1 WIP 100
4.2 WIP 10OSG
4.3 WIP 250HT
4.4 WIP 300HT
4.5 WIP400HT
4.6 WIP GRIP
NEMO ETC, LLC
Certificate of Authorization #32455
Specification
ASTM D1970
ASTM D1970
ASTM D1970 and FRSA/TRI
April 2012 (04-12)
ASTM D1970 and FRSA/TRI
April 2012 (04-12)
ASTM D1970 and FRSA/TRI
April 2012 (04-12)
Plant(s)
Description
Carlisle, PA self -adhering, fiberglass reinforced, granule
surfaced, rubberized asphalt roof underlayment
Carlisle, PA self -adhering, fiberglass reinforced, granule
surfaced, rubberized asphalt roof underlayment
Carlisle, PA self -adhering, fiberglass reinforced, film
surfaced, rubberized asphalt roof underlayment
Terrell, TX self -adhering, coated-polyolefin-composite film
surfaced, rubberized asphalt roof underlayment
Terrell, TX self -adhering, polypropylene film surfaced,
rubberized asphalt roof underlayment
ASTM D1970 Carlisle, PA self -adhering, fiberglass reinforced, film -
surfaced, rubberized asphalt roof underlayment
Evaluation Report C39180.12.11-R6
61" EDITION (2017) FBC NON-HVHZ EVALUATION FL6785-R9
Carlisle Coatings & Waterproofing; (717) 245-7000 Revision 6: 06/17/2019
Page 2 of 4
ONEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 CCW Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
Underlayment
Asphalt
Shingles
TABLE
Nail -On Tile
1: ROOF COVEROPTIONS
Foam -On Tile
Metal
Wood Shakes &
Shingles
Slate & Synthetic
Slate/Shake
WIP 100
Yes
No
No
No
No
No
WIP 10OSG
Yes
No
No
No
No
No
WIP 250HT
Yes
Yes
No
Yes
No
No
WIP 300HT
Yes
Yes
No
Yes
No
Yes
WIP 400HT
Yes
Yes
No
Yes
No
Yes
WIP GRIP
Yes
No
No
No
No
No
5.6 Allowable Substrates:
Underlayment
TABLE 2: SUBSTRATE OPTIONS
Primer
Substrates
WIP 100, WIP 250HT
(Optional) CCW-702 or CAV-GRIP
plywood
WIP 100, WIP 250HT
None
ASTM D226 felt
WIP 10OSG
CCW-702 or CAV-GRIP
plywood
WIP 300HT
(Optional) CCW-702 or CAV-GRIP
plywood, 0S13 or ASTM D226 felt
WIP 400HT
(Optional) CCW-702 or CAV-GRIP
plywood, 0S13 or ASTM D226 felt
WIP GRIP
(Optional) ASTM D41, CCW-550, CCW-702 or CAV-GRIP
plywood
ASTM D41, CCW-550, CCW-702 or CAV-GRIP
OSB
5.7 Exposure Limitations:
WIP 100 and WIP 10OSG shall not be left exposed for longer than 30-days after installation.
WIP GRIP shall not be left exposed for longer than 90-days after installation.
WIP 250HT, WIP 300HT and WIP 400HT shall not be left exposed for longer than 180-days after installation
5.8 Tile Slippage Limitations [per FRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, tile shall be staged atop a fastened
batten or toe -board, regardless of slope.
NEMO ETC, LLC Evaluation Report C39180.12.11-R6
Certificate of Authorization#32455 61" EDITION (2017) FBC NON-HVHZ EVALUATION FL6785-R9
Carlisle Coatings & Waterproofing; (717) 245-7000 Revision 6: 06/17/2019
Page 3 of 4
ONEMOletc.
6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings & Waterproofing published
installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application. Prime the substrate (if applicable) with CCW-702 or CAV-GRIP Primer.
Priming is required when temperatures are below 40°F.
6.3 WIP 100, WIP 1005G, WIP 250HT, WIP 300HT, WIP 400HT and WIP GRIP:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or
R905.1.1 for the type of prepared roof covering to be installed, and CCW published requirements.
6.3.2 Nail -On Tile Applications (WIP 250HT, WIP 300HT or WIP 400HT only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self -Adhered Membrane, and CCW
published requirements.
For mechanically fastened tile roofing over a 2-ply system, consisting of Base Sheet and Self -Adhered Membrane,
fastening of the ASTM D226, Type II base sheet shall be in accordance with CCW requirements, but not less than
that the densities set forth in FRSA/TRI April 2012 (04-12), Table 1.
Refer to Section 5.8 for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for product & production locations having met codified physical properties specifications.
UL, LLC— QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report C39180.12.11-R6
Certificate of Authorization#32455 61" EDITION (2017) FBC NON-HVHZ EVALUATION FL6785-R9
Carlisle Coatings & Waterproofing; (717) 245-7000 Revision 6: 06/17/2019
Page 4 of 4