Florida Building Code Online
BCIS Home Log In User Registration Hot7oocs Submq Surcharge Stats & Facts Publications Contact us ECIS Site Map links Search
dbpr n Product Approval
USER: Public User
Product Aograyyl Menu s Proouct or Applicatlan Search ARnlica i List > Application Detail
FL *
FL5259-R31
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phcne/Email 1111 W. Newport Center Drive
Deerfield Beach, FL. 33442
(954) 233-1330 Ext 242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(966)802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Emall 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410.1375
uspolyglasstechnical@polyglass.com
Category Roofi ng
Subcategory Underlayments
Compliance method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of independence FL5259 R31 COT 2020 01 COL NIEMINEN.p_of
Referenced Standard and Year (of Standard) Standard Year
ASTM
D1970
2015
ASTM
0226
2009
ASTM
D4798
2011
ASTM
❑6163
2015
ASTM
❑6164
2011
ASTM
D6222
2011
ASTM
D6509
2015
httpsYlwww.floddabuilding.org/prlpr_app_dil.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS°/,2(egOlip3cPzPSPEkchxoaj6Vjgl°/o2bg%3d°/o3d 112
112B/2021 Florida Building Code Online
Ful 4424
2011
FRSA/TRI, Sixth Edition
2018
UL 1897
2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product: Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
FL # Model, Number or
Name
5259.1 Polyglass Roof
Underlayments
- -
Limits of Use
Approved for use In HVH2: No
Approved for use outside HVH2: Yes
Impact Resistant: N/A
Other: Pressure: design
pree sume i
Other: 1.) The tlesign pressure in this
application relates to one particular
systems.
ent fesystem far use in the roof
systems. Refer to is ed tionmaxi Sum for other
systems and) Refer to 1 maximum design
pressures. 2.) Refer to ER Section 5 for
other limits of use.
Method 1 Option D
10/22/2020
10/26/2020
11/01/2020
12/15/2020
12/21/2020
Description
Roofing underisyments
Installation Instructions
FL5259 R31 It 2020 09 30 FINAL ER POLYGIASS UNDERLAYMENTS FLS25q-
R=pdf
Verified By: Robert Nleminen PE-59166
Created by Independent Thlrtl Parry: Yes
Evaluation Reports
by Independent Thlrtl Parry: Yes
Q
n 26m alai, Stone
a of rawm.hope:seen m 2MI p„e we :ar-low
The sum anarwa'e an Ayc6o amefoye. r'ommM zom-zr:: .. Aaesubinty sr :: humid stalwaserm
weer fecal law, map addressee are PrMIc records. if yw do not want your e-man papers relocate to reemarse u a pnmOTurds mq,eet, do not hem emcdowek
man m me employ ennead, anuct me ounce by phone or by bilateral mail. If yen hand any que0mo pease reract150.4e7.1395. murewnt m section cla.27sO1
audda humus, famous amber 1, 2012, lice was'kansed under Chaps 455, F.S. most vmy da me department wpm on code address If play have one. the malls
minded may be toed for official communication with the Ilona, however amyl addresne au public rewm. If lam do hot wash m nippy a cement' adaresu peme
proNde Me department with an email address which ran be made moilab'e to the WdW. To dNNmla If you am a licensed under Chapter 4H, FS., pkpse dick bed.
Product Approval A..P.:
Credit Card
Safe
hUpaJAm .flcridabuilding.org/pr/pr app dU.aspx7paramwGEVX0wtDgvbSgAaZp3CrUvS%2fegOlip3cPzPSPEkchxoaj6Vjgl%2bg%3d%3d 2/2
0
NEMO I etc.
Cotifmle ofAwhodmtlon 032455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
Polyglass USA, Inc. Evaluation Report P12060.02.09-1127
1111 West Newport Center Drive FL5259-R31
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954)233-1330 Revision 27: 09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FLO) preceded by the words "NEMOI etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in Its entirety.
INSPErnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 17.
Prepared by:
Robert J.M. Nieminen, P.E.
�."•'•?�
Florida Registration No. 59166, Florida OCAANE3983
';p,.,.,,,,,.,.+ mesaawae vat appeadngwaa aumahea braabert NNmmm, P.E. all
m/aa/zom. muaces,ws reN.as.n NeN.oA�,wria^"e aavvme.
CoMFICAVON OF INDEPENnmR:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is notowned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or dlstributing products for which the
evaluation reports are being Issued.
4. Robert Nieminen, P.E. does nothave, nor will acquire, a financial Interest in any other entity involved In the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019NEMOETC.MC
ONEPvi
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
fallowing sections of the 7d Edition (2020j Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein.
STANDARDS:
Section PrD a Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL1897 2015
1507.1.1/ R905.1.1 Material standard ASTM D226 2009
1507.1.1, 1507.2.4, 1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1, R905.2.8.2
1507.3.3/ R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018
1507.11.2/ R905.11.2 Material standard ASTM D6163 2015
1507.11.2/ R905.11.2 Material standard ASTM D6164 2011
1507.11.2/ R905.31.2 Material standard ASTM D6222 2011
1507,11.2/ R905.11.2 Material standard ASTM D6509 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference
Date Entireexamination Reference Date
9) Dan (Miii Wind Uplift 21757. 0.01-1O8/13/2001 ERD DST E049) 30190physicals PLYG-SC11903.03.17 03/10/2017
Ego DST Wgft Wind Uplift 1177606.02 01116/2003 ERD(TST fees) TAS 103 PLYG-SC1213S.08.17 031O1
ERD lT5T 60491 Wind Uplift P3740.01.07 01/04/2007 ERD DST 60a9) TAS 103 PLYG-SC13035.08.17 10/3l/2017
ERD (TST 631 ASTM D1970 P5110.04.071 04/11/2007 Fal UST 1867) Wind Uplift 3004091 01/I2/2WD
Dan (TST 6049) Wind Uplift P9260.03.08 03121/2008 ICC-ES(EVL 23%) IBC Compliance ESR-1697 04/01/2019
ERD ITST 60491 Wind Uplift P3054D.11.09-R1 11/30/2009 MA(CER 1592) HVHZ Compliance NOA37-0614.22 07/06/2017
ERD PSTfi049) Tensile Adhesion P11031 11/30/2W9 MTI (TST 2508) ASTM D4798 1%20H7A 04/01/20e
ERO(ATE049) Wind Uplift PI3030.11.09-2 11/30/2009 NEMOITST6049) ASTM DIWO 4ALYG-18404.03.18 03/29120M
Can(TST fi049) ASTM 04977 P11030.11.09-3 1113012M NEMOITSr6049) Wind Uplift 4L-PLYG-1800301.19 01/11/2019
FRDTf5TIS49) ASTM D1970 P33360.06.10 M/25/2010 NEMOPs"(0e9) ASTM 06163 4SPLYG-181ID2kI.19-A 01/24/2G"
ERD DST 60d9) TAS 103 P33370.03.11 03/02/2011 NEMOUS 60f9) ASTM 06222 4SPLYG-18002.05.19E 0512011019
ERDDST(i Tensile Adhesion 11,33370.04.11 04/26/2011 NEMORST6049) ASTM 01970 4F14Y 3SSUOl-0OA 0110/2019
ERD(TST6049) ASTM 01970 P37300.10.11 10/19/2011 NEMO DST 6049) TAS 103 4SPLYG-18U04.10.19G 10/00/2019
ERDDSTW49) TAS 103 P403M.08.12-1 08/06/2012 NEMODS16049) TA5103 4SPLYG-18-004.10.194 10/08/2019
ERD(MM49) Tensle Adhesion P4039108.12-2 O8/07/2012 NEMOITST6049) TAS 103 45-PLYG-13,004.103SL 10/09/2019
ERD (TST6049) Tensile Adhesion C41420.09.12-3 09/11/2012 NEMOITSr6049) TAS 103 41-PLYG 19-SSU0401.A 10/10/2019
ERD ITST 6049) Wind Uplift P39580.03.13 03/04/2013 NEMO(TST6049) TAS 103 45 PLYG-10-004.11.I9F 12/18/2019
Elio (TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO(TST6049) TAS 103 4FPLYG-I9-MUOLOEA 01/02/2020
ERD DST 6049) Wind Uplift P173802.W-R2 04/29/2013 NEMO(TST6049) ASTM 01970 4SPLYG.18404.0110.11 O1114/2020
ERD (15T 6W9) Wind Uplift 11757e,4.01-1-R3 04/30/2013 NEMOUST60,19) ASTM D1970 45-PLYG-18-004.OL20.R 01/14/2020
ERODST60 i ASTM 061" P37590.03.33-3A OS/0612013 NEMO(TST6149) TAS 103 4SPLYG-18-004.01.20A 01/16/2020
ERD DST 6PUft ASTM D6509 P37S90.03.33-1-R1 06/26/2013 NEMODSr6M9) ASTM 06164 4s-0LYG-18-004.01.20.8 01/16/20"
ERD (TST 60491 Wind Uplift P41630.08.13 08/06/2013 NEMO(TST6049) ASTMD6222 45 M-18Q111.1L19R-M 01/07/2020
ERD DST 6049) ASTM D4601 P45940.09.13 09104/2013 NEMODST6049) TAT 103 PLYG-SC15855A5.20A 05/29/2020
ERD R5T60491 Wind Uplift P31751.05.03 R3 11/26/2013 NEMO(TS76049) TAS 103 4TP1YG-2OSSUDL-01 07/06/2020
ERD (TST Golan Wind Uplift P11781.11.03.81 11/26/2013 NEMOUST6649) ASTM D6222 4q-PLYG-19-SSMBB M.A 07/23/2020
ERD (TST W91 30/90phisicals P45270.05.14 05/121 14 NEMOTMT6619) ASTM 347981 41-PLYG-19 SSUDL-0S.A 0/10/2020
ERD ITST 6049I Tensileadheslon 6020.09.14-5 09/08/2014 NEMO(TST6049) ASTM D1970 4}PLYG-20 SSUDL-0S.A 09/30/2020
ERD UST 60491 Tensile adhesion 6020.09.14-6 09/08/2014 NEMOUST6049) TAS 103 4}PLYG-2OSSUDL-0S-0 09/30/2020
ERD ITST 60491 Tensile adhesion P46520.10.14 10/03/2014 NEMO(TST6049) TAS 103 4FPLYG-20.SSUL-11 W130/2020
NEMO ETC, I.I.C. Evoluatan Report P12060.0209i
Cameo feafthdeoao.auess 7' EDITION(2020) PIC NON-HVHZ EVALUATION FL5259-1131
Pclyglass Roof Undedayments Rainvi 27:09/30/2020
Page 2 of 17
Entity
Examinallon
Re_ ferenae
Date
Eni
Examination
ERD(T316049)
aAMDWWDa98
P43290.10.14
10/17/2014
PRI (rA 5878)
Tensile Adhesion
Eno ITST 6049)
TAS 103
PLYG-SC75S0.03.15
03/24/2015
PRO ITSr 5878)
TAS 103
ERD COST Goes)
Tensileadhesi4n
P40390.04.15
04/03/2015
PRO(TST 58781
TAS 103
ERID(M6049)
TAS 103
P44360.10.14 R1
05/18/2015
FRI W5878)
TAS 103
ERD(TST 6049)
Wind Uplift
PLYG-S0905,05.16.1
05/17/2016
FRI(TST 5878)
ASTM D5222
ERDRST6049)
ASTM D1970
PLYGSCIO13D 06.161
05/27/2016
FRI RST 5878)
ASTM D6164
ERO (TST 6049)
Tensile adhesion
PLYG-SC1013006.1052
05/27/2016
Polyglass USA
PAAllidavi[
ERO(r5TE049)
TAS 103
PLYG-SC10130.06.163
06/27/2016
P4fygtasa USA
Matenesgrtdavil
ERD(TST rates)
ASTM 01970104798
PLYG SC8080.07.16
07/16/2016
UL (QUM625)
Quality Control
ERD pST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/12/2016
UL (QUA96251
Quality Control
ERO(TA 6049)
TAS 203
PLYG-SC13040. 12,16
12/27/2016
UL)QUA96251
Quallly Contra
NNE111,10jetic.
Reference Date
PRI01111 04/O3/2002
PUS VIF02-01 07/14/2003
PUSA-035-02-01 09/29/2005
PUSA-055-02-02 12/10/2007
PUSAA614202 01/28/2008
PUSA-088-02 01 07/29/2009
Mule Hide Cross US 03/01/2008
Poleatld Compound 08118/2011
Si CnnfrmHl 0atlnn 113/2018
Service Conirmadon px) 11107/2019
Florida BCIS Current
Product Material Standard Plants) Description
Elastobase ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P ASTM D6164 FL Poyyester-reinforced, SBS modified bitumen base sheet
Elastoflex S6 G ASTM D6164 Ft, PA Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
Elastoflex S6 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro ASTM 01970 FL Nominal 60-mil thick dual -layer rubberized asphalt
FRSA/TRI 09-18 waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet
(FRI FRSA/TRI 09-18
Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the
'Two Ply System" from FRSA/iRl Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
Polyflex G FOR ASTM D6222 FL Polyester -reinforced, APP modified bitumen up sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied"Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sigh
Edition beneath mechanically fastened tile roof systems
Polyfle rSA P ASTM D6222 FL, TX Polyester reinforced, APP modified bitumen cap sheet
FRSA/TR109-18
Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet
FRSA)TR109-18
Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet
4. PRODUCT DESCRIPTI
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.20
4.12
4.12
4.13
4.14
NEMO ETC, U.C. Eualuatl0n Report PUG60.02.09-1127
Carlin a WAUMonratien 0324SS 7r"EDITION(20201 Au NON-HVHZ EVALUATION F6259-R31
Polyglass Roof Underla,rants ReWsian 27:09/3012020
Page 3 of 17
4. PRODUCT DESCRIPTI
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.20
4.12
4.12
4.13
4.14
NEMO ETC, U.C. Eualuatl0n Report PUG60.02.09-1127
Carlin a WAUMonratien 0324SS 7r"EDITION(20201 Au NON-HVHZ EVALUATION F6259-R31
Polyglass Roof Underla,rants ReWsian 27:09/3012020
Page 3 of 17
M
4.15
4.16
4.17
4.18
4.19
4.20
4.21
5.1
5.2
5.3
5.4
5.5
ONEMO I etc.
DESCRIPTION:PRODUCT
Product
Material Standard
Plant(s)
Description
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick MTS Plus
ASTM D1970
FL, NV,
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI09-18
PA, TX
membrane,glass fiber reinforced, surfaced with
polyolefinic film surface
Polystick MU-X
ASTM D1970s
FL, NV, PA
Nominal 54-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane with a 190 g/m2 polyester fabric surface
Polystick TUP
FRSA/TRI0948
FL, PA, TX
Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a
granular surface
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal80-mil thick rubberized asphalt waterproofing
FRSA/TRI09-18
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
ASTM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, surfaced with a
textured film surface
This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, In any way, the Designer of Record for
any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties).
This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
IPP/ysdd MU4has beenfoundthroughcomparative testing to haven/essercoe [tentofJrittion than,lSiM DII6 roofingfeltinatlry[antlltion, teabolMstontlaM
laboraw, wnditions. Agreement between purchaser Rod seller. m setforth in Section 4.3, Note I ofASTM D197615, should be established m to slip resetance.
NEMO ETC, LLC. Ewluation Report P12060.02.09-RZ7
Cem/lmte/AUN,nNcnnn MOM 7r"EDITION (2020) FRC NON HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27: 09/30/2020
Page 4 of 17
ONEM(Djetc.
5.6 Allowable Roof Covers:
TABLE I: RoOFCOVEROPTIONS
Asphalt
Clay and Concrete The
Metal
Slate or
woad
Undedayment
Shingles
(1503.3)
Slate -Type
Mechanical
Adhesive-
Panels
Shingles
shingles
Shingles
(3soz21
shakes rysms)
Attach
set
lLwxq
(If0251
(asP).>)
pSW.g)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase
(xv.n 1.
Went w.
Iuu.eeneu,
une.naum
Veron .t.
une.nelo
Wlenmemou6
Wnemm.iooua,
oxxRixyeul
sn,.1
'++sat)
ovk Ynn,",
sn"noIs)
eatATtT+e1
rnR xa
ryxvl
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
ElastabaseP
Wemal.l.
Wurzm.n
Wu.. sneer
W.m>..
Wunm
(.n.
WInax"con',
hueleaumona,
M36. T..III
t 1all
see S.1)
ono rip 1p
@$TtAlp
oxl4 im.n)
Ttu 11)
TA."
Yes
Yes
POlyglass Base
N0
P. ease sn.ex
Wux sn.n,
No
No
No
No
No
YYes
Yes
POlyglass G2 Base
No
la+eaes
onat.ue,
No
No
No
No
No
t..s.0
s.. s3.s1
ElastoRe%SISG
No
Yes
Yes
No
No
No
No
No
ISee5.6.11
Ela$toflex S6 G FR
No
Yes
No
No
No
No
No
No
Yes
Yes
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
Yes
Ummmim.nozlu
Ueaamn,,asot.i..'
/R9V+vld1
/ates.s..31
Yes
Yes
Yes
HydraGuard Tile Pro
Yes
Yes
(see s.¢U
Yes
Yes
Yes
I\ a'Un,mnu.
sysex Raom]..
/xICAL131
/xice.Lv1
Mule -Hide SA-APP Cap Sheet
No
Yes
Yes
No
No
No
No
No
(Se
Mule -Hide SA-APP Cap Sheet (FR)
No
Yes
No
No
No
No
No
IseYes.il
PolygexG
No
Yes
Yes
No
No
No
No
N0
I
(See SX..I
POlyvex G FR
No
Yes
No
No
No
No
No
No
POIyNex SAP
No
Yes
Yes
No
No
No
No
No
(lee B.6.11
PolyRex SA P FR
No
Yes
Yes
No
No
No
No
No
(sees 6.1)
Yes
Yes
Polystick lR-Xe
Yes
No
No
No
No
Yes
ygntrvlpxuot.vl.a
W.'Mw,sem.1.
/MM11.31
I /Atle.L.)
Yes
Vm
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
Yes
OumuM lsm.m
Ilounwgx aunt]
/xM.LLa)
/aW5.1..'
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
U.xuwq.txA.t]]
0.Im AnA'ese.1.13
/x9n,,I IJtYes
/Raae.l.l31
Yes
Yes
Polystick TU Max
No
Yes
(.a 5.6.11
Yes
Yes
No
6AxasOS]. iN�u..
uso'1
golmao-plasmt]3
/Rrw
/x955].131
Yet
es
Y(see
Yes
Polystick TUP
No
Yes
SA.11
No
No
No
Ue"no"i,.
Udm Rasn,wo`.
/wm.t131
/xmll..)
Yes
s
Yes
Palystick TU Plus
Yet
Yes
($,156.1)
Yes
Yes
Yes
gdmerlp; lwzl.
Ummnnm, asm.ua
IemaLt)
/Mm3..I
Yes
Yes
Polystick XFR
Yes
Yes
No
Yes
Yes
Yes
lymmlq,.7.1.
linen LIIolv3
/pm.s331
Isom.,..)
NEMO ETC, LUC. Evaluation Report P12060.01.09-R22
Cetroon cal,hrboi+otlnn#32055 7- EDITION (2020) FSC NON-HVH2 EVALUATION FL1259-R31
P.I,I... goof Underlayments RIVIsIOn 27:09/30/2020
Page 5of 17
NNEMOjetc.
5.6.1 Adhesive -set tile is limited to use of the following underlayment/tile-adhesive combinations.
TABLE IA: ALLOWABLE UNDERLAYMENT/ TILE-AOHtswe COMBINATIONS'
Undedayment
Adhesive
Florida Product Approval
Polystick TU Max or Polystick TU Plus
DAP FOam"Touch 'n Seal
FL14506
StormBoad Roof Tile Adhesive"
HydraGuard Tide Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick
Dupont Tile Bond'" Hoof Tile
FU2525
TU Plus
Adhesive"
Elastoflex 56 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P Fit, Polystick TU Max,
"polyset• AH-160"
FL6332
Polystick TU P or Polystick TU Plus
Elastoflex 56 G, HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet, Mule -Hide SA-
ICP Adhesives and Sealants
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P Fit, Polystick TU Max,
•polyset•ivesan
FL6276
Polystick TU P or Polystick TU Plus
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERIAYMENTS
Substrates (designed to meet wind loads for project)
Undedayment
Application
Type Printer Matedai(s)
HydraGuard Dual Pro,
(Optional)ASTM
plywood,058, Southern Yellow Pine or Huber Engineered
HydraGuard Tile Pro, Polystick IR-
Deck
D41
Woods" ZIP System- Panels
Xe, Polystick MTS Plus, Polystick
sheathing
ASTM D41
structural concrete
MU-X, Polystick TU Max,
self-
ASTM C1289 Type II Class 1 polyisocyanurate, ASTM
Polystick TU P, Polystick TU Plus,
adhering
Insulation
(Optional)ASTM
C1289 Type V polyisocyanumtecomposite,DensDeck
Polystick XFR, Mule -Hide SA-APP
041 or WB-3000
Prime or SECUROCK Gypsum -Fiber Root Board
Cap Sheet Mule -Hide SA-APP
Cap Sheet (FIR), Polyflex SA P or
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P or Mule.
Polyflex SA P FR
I
Hide Nail Base
Deck
ASTM 041
structural concrete
Insulation
(Optional)ASTM
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Elastoflex SG G or Elastoflex S6 G
hot asphalt
D41
FR
ASTM D226, Type II felt, Elastobase, Elastobase P, Mule -
Base Sheet
N/A
Hide Nail Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Insulation
(Optional)ASTM
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
torch-
Polyflex G or Polyflex G FR
applied
D41
Base Sheet
N/A
Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass
G2 Base or Polyglass Base
2 Refer to Tile Manufacturer's co -Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC. Evaluation Report P32060.02.09-R27
Cem/k•teo/AUtMtlmt1onp31455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FI5259-R31
Polyglass Roof Underlayments Ralston 27:09/3012020
Page 6 of 17
ONEMOletc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturers installation instructions, but— for mechanically attached undedayments or base sheets - not less than FBC
1S07.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturers installation instructions, but —
for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High WindConcrere and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,Table l(forTwo-
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/FRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table lA or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-52.5 psf:
Deck: APArated,7/16CAT,0.418 in., Exposure 1, OSBsheathingto meet project requirementsto satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-Inch wide strips of Elastoflex SA-V aver all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polysdck TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
R2 Maximum Design Pressure =-90 osf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FIR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
93 Maximum Design Pressure=-97.5 osf:
Deck: MIn.15/324rch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PGI00 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x lY." ring shank
nails through 32 ga.,1-5/8" diameter tin raps spaced 12-inch o.c.
g4 Maximum Design Pressure =-105 osf:
Deck: MIn.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x lY' Ong shank
nails through 32 Be., 1-5/e" diameter tin caps spaced 12-inch o.c.
NEMO ETC, L-C. Evaluation Report P32060.02.09-1117
Cif to alAudow ton e32a55 7-EDITION OOZO) FBC NON HVHZ EVALUATION FI5259-1131
Polyglass Roof Underlayments Reuiidim 27: 09/30/1020
Page 7 of 17
ONEMOletc.
05 Maximum Design Pressure=-135 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG1W or ASTM D41
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule -Hide SA-APP tap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
R6 Maximum Design Pressure=-315 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet ER), Polyflex SA P, Polyflex SA P Fit,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
g7 Maximum Design Pressure=-622.5 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG300 or ASTM D41
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
R8 All other direct -deck, adhered Underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf.
5.8.3.2 Mechanically -Attached Base Sheet
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table SA or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RA5137. Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
d9 Maximum Design Pressure =-30.0 osf•:
Deck: Min.15/32-Inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastabase or Mule -Hide Nail Base)poly-film top surface)
Fasteners: 11 ga. x 1.15-Inch long x lArch head diameter round metal cap nails
Spacing: &inch o.c. at the 3-inch wide side laps and&inch o.c.at me (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
010 Maximum Design Pressure = .37.5 osf :
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply; (Optional) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
1131 Maximum Design Pressure =-37.5 osf
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-Inch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R27
Certlflmre o)AuMmivexe#32455 7- EDITION (2020)FBC NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof UnderlaVments Revision 27:09/30/2020
Page 8 of 17
NNEMO Ietc.
012 Maximum Design Pressure =-45 osf-:
Deck: Min.19/32-Inch plywood to meet projectrequirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inchx3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch D.C. at the 2-Inch wide side laps and 4-inch D.C. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#13 Maximum Design Pressure =-45 osf•:
Deck: Min.19/32unch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Two (2) layers ASTM D226, Type ll felt
Fasteners: 11 Be. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 9-inch D.C. at the 2-inch wide side laps and 9-inch D.C. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or ElastoFlex S6 G, applied in full mopping of hot asphalt.
#14 Maximum Design Pressure=-45 Osf:
Deck: Min.I5/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied Cap or poly -film surface fortorch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch D.C. at the 2-inch wide side laps and 18-inch out. at two (2) equally spaced staggered center rows.
Underlayment ElastoFlex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#15 Maximum Design Pressure = -45.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/9" diameter tin caps
Spacing: 6-Inch o.c. at the 3-inch wide side laps and 6-inch D.C. at four (4) equally spaced staggered center rows.
Base Ply: (Optional( Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyfex SA P. Polyfex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#16 Maximum Design Pressure=-45.0 osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB Sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (send top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/8' diameter tin caps
Spacing: 64nch D.C. at the 3-inch wide side laps and 6-inch D.C. at four (4) equally spaced staggered center rows.
Underlayment ElastoFlex S6 G, applied in full mopping of hot asphalt.
#17 Maximum Design Pressure = -45.0 DO:
Deck: APA rated,7116 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch D.C. at four (4) equally spaced staggered center rows.
Underlayment Polyflex G, torch -applied.
#18 Maximum Design Pressure =-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAX% Cap Fasteners
Spacing: 9-inch O.C. at the 2-inch wide side laps and 12-inch D.C. at two (2) equally spaced staggered center rows.
Underlayment Elasto8ex S6 G, applied in full mopping of hot asphalt 0r Polyflex G, torch -applied.
NEMO ETC, LLC, Evaluallan Report P12060.01.09-1127
CeTfiwrco/AuflwrWCon p32155 lam EDITION 12020)FBC NON-HVHZ EVALUATION FB259 R31
Polyglass Roof Ondedayments Revision 27: 09/30/2020
Page 9 of 17
ONEMOJetc.
H19 Maximum Design Pressure =-52.5 its
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-Inch o.c. at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polysdck TU Max, Polystick
TU P or Polystick TV Plus, self -adhered.
N20 Maximum Design Pressure =.52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap No Its
Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure =-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having lurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch tong x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment Elastoflex 56 G, applied in ful I mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure =.60 psf
Deck: Min.19/32Anch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG#12 Standard Roc ip with OMG Flat Bottom Metal Plates
Spacing: 12-Inch o.c. at the 4dnch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#23 Maximum Design Pressure =-60.0 osf:
Deck: APA rated, 7116 CAT, 0.418 In., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (ply -film top surface)
Fasteners: Simplex MAX% Cap Fasteners
Spacing: 8-Inch o.c. at the 3-Inch wide side laps and 8-Inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TV P or Polystick TV Plus, self -adhered.
#24 Maximum Design Pressure =-60.0 psf:
Deck: APA reted,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-Inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex SG G, applied in full mopping of hot asphalt.
025 Maximum Design Pressure = -60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-Inch wide side laps and I inch o.c. at three (3) equally spaced staggered center rows.
Underlayment Polyflex G, torch -applied.
NEMO ETC, LLC. Evaluation Report P32060.02.09-R27
Cert4lmte ufaudur0etlun#32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof UndedaymeMs Revision 27:09/30/2020
Page 10 or 17
NNEMOletc.
#26 Maximum Design Pressure = -67.5 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use oftorch-opplied underfayment)
Fasteners: 12 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 8-Inch o.c. at the 4-Inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#27 Maximum Design Pressure=-67.5 osf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180* into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-Inch o.c. at the 4-Inch wide side laps and 12-Inch Oc. at two (2) equally spaced staggered center rows.
Primer: (Optional) PG 100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polvflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
928 Maximum Design Pressure =-67.S osf:
Deck: APA rated, 19/32 CAT, 0,578 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand tap surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180'into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-Inch wide side laps and 12-inch o.c. at two (21 equally spaced staggered center rows.
Underlayment Elastoflex 56 G, applied in full mopping of hot asphalt.
#29 Maximum Design Pressure =-67.5 osf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, O5B sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' Into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Polynex G, torch -applied.
#30 Maximum Design Pressure=-75 osf:
Deck: MIn.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base frequlres use cftorchopplied underlayment)
Fasteners: Dekfxt#14 with Dekfast Hex plates, OMG #14 HD with OMG 3' Galvalume Steel Plates, OMG Roofgdp#14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Tmfast 3-inch Insulation Plates or Simplex MAU Cap Fasteners
Spacing: 30-Inch o.c. at the 4-Inch wide side laps and 30-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied In full mapping of hot asphalt ortorch-applled or Polyflex G, torch -applied.
#31 Maximum Design Pressure =-90 psf:
Deck: MIn.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded cep surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAU Cap Fasteners
Spacing: 6-inch o.c. at the 2-Inch wide side laps and&inch o.c.attwo (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#32 Maximum Design Pressure =.90 psf:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cep)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or DIMS flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R27
RM)¢oteojautlwtlmtbn.32151 7' EDITION (20201 FBC NON-HVHZ EVALUATION R5259-R31
Polyglass RPof Undedayments Revision 27: 09/30/2020
Page 11 of 17
NNEMOletc.
#33 Maximum Design Pressure =-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#34 Maximum Design Pressure =-90 nsf:
Deck: Min. 1S/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base frequires use ofearchmpplied underlayment/
Fasteners: Dekfast#14 with Dekfast Hex plates, OMG H14 HD with OMG 3" Galvalume Steel Plates, OMG Roofil#14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAxx Cap Fasteners
Spacing: 9-inch o.c. at the 4-Inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#35 Maximum Design Pressure=-90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having
Junsdiction.
Base Sheet Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180' Into the holes of the plate, parallel to
the width-chrection of the sheet
Spacing: 9-Inch o.c. at the 2-inch wide side laps and 12-inch cre. at two (2) equally spaced staggered center rows.
Primer. PGIOD or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#36 Maximum Design Pressure=-90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 In., Exposure 1, OSB sheathing to meet projectrequirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-Inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Elastoflex S6 G, applied In full mopping of hot asphalt.
#37 Maximum Design Pressure=-90.0 psf:
Deck: APA rated, 7/16 CAT, 0.418 In., Exposure 1, OSB Sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the hales of the plate, parallel to
the widthdiredion of the sheet
Spacing: 9-Inch o.c. at the 2-inch wide side laps and 12-Inch o.c. at two (21 equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#38 Maximum Design Pressure =-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet. Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-Inch x 3/8-Inch head diameter annular ring shank roofing nails at 1.5/84ch diameter tin caps
Spacing: 4-Inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, LLQ Eualuatlon Report P3Z060.02.09-R27
Cvrlftwreo1Au0vUvdaa032455 7- EDITION (2020) Fee NON-HVHZ EVALUATION FL5259-1131
Polyglass Roof UndeHayments Revision 27:09/3012020
Page 12 of 17
NNEMOletc.
#39 Maximum Design Pressure=-97.5 Pst:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(poly-fllm top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASfM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), PolyBex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#40 Maximum Design Pressure =-97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand tap surface)
Fasteners: Simplex MAXX Cap Fasteners
Sparing: 6-Inch oa, at the 4-Inch wide side laps and 6-Inch o.c. at four (41 equally spaced staggered center rows.
Underlayment: ElastoRex 56 G, applied in full mopping of hot asphalt.
#41 Maximum Design Pressure =.97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch Oc. at the 4-inch wide side laps and 6-inch Oc. at four (4) equally spaced staggered center rows.
Underlayment Polynex G, torch -applied.
942 Maximum Design Pressure =-105 psf:
Deck: Min.15/32-Inch plywood t0 meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-Inch ox. at the 2-Inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Undedayment: ElastoRex 56 G, applied In full mopping of hot asphalt or PDlyfiex G, torch -applied.
043 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CRT, 0.418 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners &Plates with two screws per plate installed 1804 into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: &inch o.c. at the 4-Inch wide side laps and 6-inch Oc. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRj, Polyfiex SA P, POlyfiex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#44 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -fast Fasteners & Plates with two (2) screws per plate installed 180' into the hales Of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: ElastoOex S6 G, applied in full mapping of hot asphalt.
NEMO ETC, U.C. Evaluation Report P12060.01.09-R27
Cen111mr, Of AutM1ONotlan#114SS 7- EDITION (2020) FBC NON-HVH2 EVALUATION F1.5259-1131
Polyglass Roof Undedayments Revision 27: 09/30/2020
Page 13 of 17
NNEMOletc.
#45 Maximum Design Pressure=-105.0 Dsf:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase Or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two screws per plate Installed 180' into the holes of the plate, parallel to
the width -direction Of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c- at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#46 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga.x 1.25-inchx3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG 100 or ASTM D41 primer at all tin -ups
Base Ply: Polystick NITS Plus, seltUadhered
Underlayment: Mule -Hide WARP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#47 Maximum Design Pressure=-120 psf:
Deck: Min. 35/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase(sanded tap surface for hot -asphalt or torch -applied cap or poly- film surface for torch -applied tap)
Fasteners: OMG #12 Standard ROOfgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or DING Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment Elostoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#48 Maximum Design Pressure=-120 Dsf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at five (5) equally spaced staggered center rows.
Underlayment Elasroflex S6 G, applied in full mopping of hot asphalt.
#49 Maximum Design Pressure=-127.5 of :
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction Of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(poly-film tap surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#50 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fart Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-Inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elasroflex S6 G, applied in full mopping of hot asphalt.
#51 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, OSB sheathing t0 meet project requirements t0 satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners&Plates with one (1) screw per plate, in the center hole.
Spacing: 9-Inch o.c. at the 4-inch wide side laps and 9-Inch o.c. at four (4) equally spared staggered center rows.
Underlayment Polynex G, torch -applied.
NEMO ETC, I.I.C. Evaluation Report P32060.02.09-f137
Gorfrt of Authoriodor#32435 7-EDITION JZ0ZO)FBC NON-HVHZ EVALUATION F15259-1131
PoWass Roof Undedaymems Revision 27:09130/20ZO
Page 14 of 17
NNEMOjetc.
5.9 Exposure Limitations:
TABLE3: EXPOSURELimmATIONS
Underlayment
Prepared Roof Cover
Installation Type
Maximum
Exposure(days)
Elastobase, Elastobase P, Painless G2 Base or Polyglass Base
Mechanically attached
30
Polystick lR-Xe or Polystick MU-X
Mechanically attached
90
HydraGuard Dual Pro, HydraGuard Tile Pm, Polystick MIS Plus, Polystick TU Max, Polystick
TU P, Polystick TU Plus or Polystick XFR
Any type (per Table l)
ISO
Eleano0ex S6 G, Elastollex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap
Sheet (FR), Poly0ex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
Adhesive -set tile roof system
ISO
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the maximumroof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE4: TRESUPPAGE LIMRATIONS MR DIRECT-DECXTILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Staging Slope
ElastoRex S6 G or S6 G FR
Flat or Lugged
6-tile stack III over 2)
Prohibited without battens
HydraGuard Tile Pm
Flat or Lugged
6-tile stack is over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack(4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack i4 over 2)
4:12
Polystick NITS Plus
Flat
6-tile stack(4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack(4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TUP
Flat or Lugged
6-tile stack(4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
6-tile stack III Over 2)
7:12
Flat .,Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
NEMO ETC, U.C. Evaluation Report P12000.02.09-R27
rirtllkateafAuthodevelona37455 7- EDITION (2020) FaC NON-HVHZ EVALUATION F15259-1131
Polyglass Roof underlayments Revision 27: 09/30/2020
Page 15 of 17
ONEMOjetc.
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be Installed, and the
manufacturer's Installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase, Elastobase P or Mule -tilde Nall Base may be covered with a layer of Polystick IR-Xe, Polystick NITS Plus, Polystick
MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex 56 G or Elastoflex 56 G FR in hot asphalt or Polyflex G or Polyflex G
FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table
1.
6.3.2 Tile Applications:
6.3.2.1 Elastobase (poly-fllm top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached
base sheet in the -MO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay RaofTile Installation Manual, Sixth
Edition, followed by Polystick MTS Plus, Polystick TU Max, PolystickTU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex
SAP FR, MuIe-HIde SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR,torch-applied. Tile
roof Installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
6.3.2.2 Elastobase (sanded -top) and Elastobase P(sanded-top)e are limited to use as a mechanically attached base sheet in the `TM/0-
PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by
Elastoflex S6 G, Elastoflex 56 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex
G or Polyflex G FR. torch -applied. Tile roof Installation method is limited by the selected Cap Sheet, as set forth in Table 1.
• When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex 56 G, Elastoflex 56
G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/I-RI, Sixth Edition, Appendix A, Table 1
or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase (sanded -top) or Elastobase P(sanded-top) is followed by torch -applied Polyflex G or Polyflex G FR, refer
to Section 5.8.3.2 herein for attachment requirements.
6.4 HydraGuard Dual Pro, HVdraGuard Tile Pro, MuIe-Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P,
Polyflex SA P FR, Polystick IR-Xe, Polystick NITS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or
Polystick XFR:
6.4.1 General:
All seal -lap seams (selvage laps) must be firmly rolled with a
in accordance with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric(.
View of creep Seam of HydraGuard Dual Pro and HydraGuard The Pro
NEMO ETC U.C. Evaluarlon Rep.N P32060.02.09-RZ7
Onme ne efAutho@otion#32a55 Tr°EDITION (2020) Fee NON-HVHZ EVALUATION FL5159-R31
Polyglass Roof Underlayments R.Won 27:09/3012020
Page 16 of 17
NNEMOjetc.
6.4.2 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.2.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be Installed,
and the manufacturer's installation instructions.
When Installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase, Elastobase P or
Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.3 Tile Applications (excludes HydraGuard Dual Pro. Polystick lR-Xe and Polystick MU-X):
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind
Concrete and Clay Roof rile Installation Manual, Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi -Ply Underlavment Svsteme:
Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro, PolyRex SA P, Polystick MTS Plus, Polystick MU-X, Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR Is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top -layer material. This Is not a requirement, but is allowable if a 2-ply
underlayment system Is desired,
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyfiex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not
requirement, but Is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S5 G or ElastoRex S6 G FR:
6.5.1 Shall be Installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply
System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation Instructions.
Refer to Section 5.8.2 and S.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.6 PolyRex G or PolyRex G FR:
6.6.2 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" In the "Two Ply System" In
the FRSA/TRI Florida High Wind Concrete and Cloy Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
8. MANUFACTURING PUNTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA requirements. Refer to Section
4 herein for products and production locations having met codified material standards.
9. P .
UL LLC — CUA9625; (414) 248-6409; Karen.buchmann(dul.com
END OF EVALUATION REPORT -
NEMO ETC, LLC. Evaluation Repart P32060.02.09-R27
con,flmttal<uftnanon.32455 7"EDITION (2020)FBC NON-HVH2 EVALUATION F1.5259-R31
Po1vg1as5 Roof Unduruvo ents Revlslon 27; 09/30/202D
Page 17 of 17