Loading...
HomeMy WebLinkAboutAPPROVED MYERS_polyglass_tu-max_underlayment_product_approval.pdf/26/2021 Florida Building Code Online BCIS Home Log In User Registration Hot7oocs Submq Surcharge Stats & Facts Publications Contact us ECIS Site Map links Search dbpr n Product Approval USER: Public User Product Aograyyl Menu s Proouct or Applicatlan Search ARnlica i List > Application Detail FL * FL5259-R31 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phcne/Email 1111 W. Newport Center Drive Deerfield Beach, FL. 33442 (954) 233-1330 Ext 242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (966)802-8017 uspolyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Emall 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888)410.1375 uspolyglasstechnical@polyglass.com Category Roofi ng Subcategory Underlayments Compliance method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of independence FL5259 R31 COT 2020 01 COL NIEMINEN.p_of Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM 0226 2009 ASTM D4798 2011 ASTM ❑6163 2015 ASTM ❑6164 2011 ASTM D6222 2011 ASTM D6509 2015 httpsYlwww.floddabuilding.org/prlpr_app_dil.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS°/,2(egOlip3cPzPSPEkchxoaj6Vjgl°/o2bg%3d°/o3d 112 112B/2021 Florida Building Code Online Ful 4424 2011 FRSA/TRI, Sixth Edition 2018 UL 1897 2015 Equivalence of Product Standards Certified By Sections from the Code Product: Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Summary of Products FL # Model, Number or Name 5259.1 Polyglass Roof Underlayments - - Limits of Use Approved for use In HVH2: No Approved for use outside HVH2: Yes Impact Resistant: N/A Other: Pressure: design pree sume i Other: 1.) The tlesign pressure in this application relates to one particular systems. ent fesystem far use in the roof systems. Refer to is ed tionmaxi Sum for other systems and) Refer to 1 maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Method 1 Option D 10/22/2020 10/26/2020 11/01/2020 12/15/2020 12/21/2020 Description Roofing underisyments Installation Instructions FL5259 R31 It 2020 09 30 FINAL ER POLYGIASS UNDERLAYMENTS FLS25q- R=pdf Verified By: Robert Nleminen PE-59166 Created by Independent Thlrtl Parry: Yes Evaluation Reports by Independent Thlrtl Parry: Yes Q n 26m alai, Stone a of rawm.hope:seen m 2MI p„e we :ar-low The sum anarwa'e an Ayc6o amefoye. r'ommM zom-zr:: .. Aaesubinty sr :: humid stalwaserm weer fecal law, map addressee are PrMIc records. if yw do not want your e-man papers relocate to reemarse u a pnmOTurds mq,eet, do not hem emcdowek man m me employ ennead, anuct me ounce by phone or by bilateral mail. If yen hand any que0mo pease reract150.4e7.1395. murewnt m section cla.27sO1 audda humus, famous amber 1, 2012, lice was'kansed under Chaps 455, F.S. most vmy da me department wpm on code address If play have one. the malls minded may be toed for official communication with the Ilona, however amyl addresne au public rewm. If lam do hot wash m nippy a cement' adaresu peme proNde Me department with an email address which ran be made moilab'e to the WdW. To dNNmla If you am a licensed under Chapter 4H, FS., pkpse dick bed. Product Approval A..P.: Credit Card Safe hUpaJAm .flcridabuilding.org/pr/pr app dU.aspx7paramwGEVX0wtDgvbSgAaZp3CrUvS%2fegOlip3cPzPSPEkchxoaj6Vjgl%2bg%3d%3d 2/2 0 NEMO I etc. Cotifmle ofAwhodmtlon 032455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT Polyglass USA, Inc. Evaluation Report P12060.02.09-1127 1111 West Newport Center Drive FL5259-R31 Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009 (954)233-1330 Revision 27: 09/30/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FLO) preceded by the words "NEMOI etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in Its entirety. INSPErnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 17. Prepared by: Robert J.M. Nieminen, P.E. �."•'•?� Florida Registration No. 59166, Florida OCAANE3983 ';p,.,.,,,,,.,.+ mesaawae vat appeadngwaa aumahea braabert NNmmm, P.E. all m/aa/zom. muaces,ws reN.as.n NeN.oA�,wria^"e aavvme. CoMFICAVON OF INDEPENnmR: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is notowned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or dlstributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does nothave, nor will acquire, a financial Interest in any other entity involved In the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019NEMOETC.MC ONEPvi ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the fallowing sections of the 7d Edition (2020j Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. STANDARDS: Section PrD a Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL1897 2015 1507.1.1/ R905.1.1 Material standard ASTM D226 2009 1507.1.1, 1507.2.4, 1507.2.9.2/ Material standard ASTM D1970 2015 R905.1.1, R905.2.8.2 1507.3.3/ R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507.11.2/ R905.11.2 Material standard ASTM D6163 2015 1507.11.2/ R905.11.2 Material standard ASTM D6164 2011 1507.11.2/ R905.31.2 Material standard ASTM D6222 2011 1507,11.2/ R905.11.2 Material standard ASTM D6509 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date Entireexamination Reference Date 9) Dan (Miii Wind Uplift 21757. 0.01-1O8/13/2001 ERD DST E049) 30190physicals PLYG-SC11903.03.17 03/10/2017 Ego DST Wgft Wind Uplift 1177606.02 01116/2003 ERD(TST fees) TAS 103 PLYG-SC1213S.08.17 031O1 ERD lT5T 60491 Wind Uplift P3740.01.07 01/04/2007 ERD DST 60a9) TAS 103 PLYG-SC13035.08.17 10/3l/2017 ERD (TST 631 ASTM D1970 P5110.04.071 04/11/2007 Fal UST 1867) Wind Uplift 3004091 01/I2/2WD Dan (TST 6049) Wind Uplift P9260.03.08 03121/2008 ICC-ES(EVL 23%) IBC Compliance ESR-1697 04/01/2019 ERD ITST 60491 Wind Uplift P3054D.11.09-R1 11/30/2009 MA(CER 1592) HVHZ Compliance NOA37-0614.22 07/06/2017 ERD PSTfi049) Tensile Adhesion P11031 11/30/2W9 MTI (TST 2508) ASTM D4798 1%20H7A 04/01/20e ERO(ATE049) Wind Uplift PI3030.11.09-2 11/30/2009 NEMOITST6049) ASTM DIWO 4ALYG-18404.03.18 03/29120M Can(TST fi049) ASTM 04977 P11030.11.09-3 1113012M NEMOITSr6049) Wind Uplift 4L-PLYG-1800301.19 01/11/2019 FRDTf5TIS49) ASTM D1970 P33360.06.10 M/25/2010 NEMOPs"(0e9) ASTM 06163 4SPLYG-181ID2kI.19-A 01/24/2G" ERD DST 60d9) TAS 103 P33370.03.11 03/02/2011 NEMOUS 60f9) ASTM 06222 4SPLYG-18002.05.19E 0512011019 ERDDST(i Tensile Adhesion 11,33370.04.11 04/26/2011 NEMORST6049) ASTM 01970 4F14Y 3SSUOl-0OA 0110/2019 ERD(TST6049) ASTM 01970 P37300.10.11 10/19/2011 NEMO DST 6049) TAS 103 4SPLYG-18U04.10.19G 10/00/2019 ERDDSTW49) TAS 103 P403M.08.12-1 08/06/2012 NEMODS16049) TA5103 4SPLYG-18-004.10.194 10/08/2019 ERD(MM49) Tensle Adhesion P4039108.12-2 O8/07/2012 NEMOITST6049) TAS 103 45-PLYG-13,004.103SL 10/09/2019 ERD (TST6049) Tensile Adhesion C41420.09.12-3 09/11/2012 NEMOITSr6049) TAS 103 41-PLYG 19-SSU0401.A 10/10/2019 ERD ITST 6049) Wind Uplift P39580.03.13 03/04/2013 NEMO(TST6049) TAS 103 45 PLYG-10-004.11.I9F 12/18/2019 Elio (TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO(TST6049) TAS 103 4FPLYG-I9-MUOLOEA 01/02/2020 ERD DST 6049) Wind Uplift P173802.W-R2 04/29/2013 NEMO(TST6049) ASTM 01970 4SPLYG.18404.0110.11 O1114/2020 ERD (15T 6W9) Wind Uplift 11757e,4.01-1-R3 04/30/2013 NEMOUST60,19) ASTM D1970 45-PLYG-18-004.OL20.R 01/14/2020 ERODST60 i ASTM 061" P37590.03.33-3A OS/0612013 NEMO(TST6149) TAS 103 4SPLYG-18-004.01.20A 01/16/2020 ERD DST 6PUft ASTM D6509 P37S90.03.33-1-R1 06/26/2013 NEMODSr6M9) ASTM 06164 4s-0LYG-18-004.01.20.8 01/16/20" ERD (TST 60491 Wind Uplift P41630.08.13 08/06/2013 NEMO(TST6049) ASTMD6222 45 M-18Q111.1L19R-M 01/07/2020 ERD DST 6049) ASTM D4601 P45940.09.13 09104/2013 NEMODST6049) TAT 103 PLYG-SC15855A5.20A 05/29/2020 ERD R5T60491 Wind Uplift P31751.05.03 R3 11/26/2013 NEMO(TS76049) TAS 103 4TP1YG-2OSSUDL-01 07/06/2020 ERD (TST Golan Wind Uplift P11781.11.03.81 11/26/2013 NEMOUST6649) ASTM D6222 4q-PLYG-19-SSMBB M.A 07/23/2020 ERD (TST W91 30/90phisicals P45270.05.14 05/121 14 NEMOTMT6619) ASTM 347981 41-PLYG-19 SSUDL-0S.A 0/10/2020 ERD ITST 6049I Tensileadheslon 6020.09.14-5 09/08/2014 NEMO(TST6049) ASTM D1970 4}PLYG-20 SSUDL-0S.A 09/30/2020 ERD UST 60491 Tensile adhesion 6020.09.14-6 09/08/2014 NEMOUST6049) TAS 103 4}PLYG-2OSSUDL-0S-0 09/30/2020 ERD ITST 60491 Tensile adhesion P46520.10.14 10/03/2014 NEMO(TST6049) TAS 103 4FPLYG-20.SSUL-11 W130/2020 NEMO ETC, I.I.C. Evoluatan Report P12060.0209i Cameo feafthdeoao.auess 7' EDITION(2020) PIC NON-HVHZ EVALUATION FL5259-1131 Pclyglass Roof Undedayments Rainvi 27:09/30/2020 Page 2 of 17 Entity Examinallon Re_ ferenae Date Eni Examination ERD(T316049) aAMDWWDa98 P43290.10.14 10/17/2014 PRI (rA 5878) Tensile Adhesion Eno ITST 6049) TAS 103 PLYG-SC75S0.03.15 03/24/2015 PRO ITSr 5878) TAS 103 ERD COST Goes) Tensileadhesi4n P40390.04.15 04/03/2015 PRO(TST 58781 TAS 103 ERID(M6049) TAS 103 P44360.10.14 R1 05/18/2015 FRI W5878) TAS 103 ERD(TST 6049) Wind Uplift PLYG-S0905,05.16.1 05/17/2016 FRI(TST 5878) ASTM D5222 ERDRST6049) ASTM D1970 PLYGSCIO13D 06.161 05/27/2016 FRI RST 5878) ASTM D6164 ERO (TST 6049) Tensile adhesion PLYG-SC1013006.1052 05/27/2016 Polyglass USA PAAllidavi[ ERO(r5TE049) TAS 103 PLYG-SC10130.06.163 06/27/2016 P4fygtasa USA Matenesgrtdavil ERD(TST rates) ASTM 01970104798 PLYG SC8080.07.16 07/16/2016 UL (QUM625) Quality Control ERD pST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 UL (QUA96251 Quality Control ERO(TA 6049) TAS 203 PLYG-SC13040. 12,16 12/27/2016 UL)QUA96251 Quallly Contra NNE111,10jetic. Reference Date PRI01111 04/O3/2002 PUS VIF02-01 07/14/2003 PUSA-035-02-01 09/29/2005 PUSA-055-02-02 12/10/2007 PUSAA614202 01/28/2008 PUSA-088-02 01 07/29/2009 Mule Hide Cross US 03/01/2008 Poleatld Compound 08118/2011 Si CnnfrmHl 0atlnn 113/2018 Service Conirmadon px) 11107/2019 Florida BCIS Current Product Material Standard Plants) Description Elastobase ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet Elastobase P ASTM D6164 FL Poyyester-reinforced, SBS modified bitumen base sheet Elastoflex S6 G ASTM D6164 Ft, PA Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI 09-18 Elastoflex S6 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI 09-18 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface HydraGuard Tile Pro ASTM 01970 FL Nominal 60-mil thick dual -layer rubberized asphalt FRSA/TRI 09-18 waterproofing membrane, fiberglass reinforced, with a polyester fabric surface Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI 09-18 Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet (FRI FRSA/TRI 09-18 Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/iRl Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition beneath mechanically fastened or adhered tile roof systems Polyflex G FOR ASTM D6222 FL Polyester -reinforced, APP modified bitumen up sheet for FRSA/TRI 09-18 use as an alternate to Heat Applied"Cap Sheet" in the "Two Ply System" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sigh Edition beneath mechanically fastened tile roof systems Polyfle rSA P ASTM D6222 FL, TX Polyester reinforced, APP modified bitumen cap sheet FRSA/TR109-18 Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet FRSA)TR109-18 Polyglass Base ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet 4. PRODUCT DESCRIPTI 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.20 4.12 4.12 4.13 4.14 NEMO ETC, U.C. Eualuatl0n Report PUG60.02.09-1127 Carlin a WAUMonratien 0324SS 7r"EDITION(20201 Au NON-HVHZ EVALUATION F6259-R31 Polyglass Roof Underla,rants ReWsian 27:09/3012020 Page 3 of 17 4. PRODUCT DESCRIPTI 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.20 4.12 4.12 4.13 4.14 NEMO ETC, U.C. Eualuatl0n Report PUG60.02.09-1127 Carlin a WAUMonratien 0324SS 7r"EDITION(20201 Au NON-HVHZ EVALUATION F6259-R31 Polyglass Roof Underla,rants ReWsian 27:09/3012020 Page 3 of 17 M 4.15 4.16 4.17 4.18 4.19 4.20 4.21 5.1 5.2 5.3 5.4 5.5 ONEMO I etc. DESCRIPTION:PRODUCT Product Material Standard Plant(s) Description Polystick IR-Xe ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI09-18 PA, TX membrane,glass fiber reinforced, surfaced with polyolefinic film surface Polystick MU-X ASTM D1970s FL, NV, PA Nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane with a 190 g/m2 polyester fabric surface Polystick TUP FRSA/TRI0948 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface Polystick TU Plus ASTM D1970 FL, PA, TX Nominal80-mil thick rubberized asphalt waterproofing FRSA/TRI09-18 membrane, glass fiber reinforced, with a polyester fabric surface Polystick XFR ASTM D1970 NV, TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane, glass fiber reinforced, surfaced with a textured film surface This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. IPP/ysdd MU4has beenfoundthroughcomparative testing to haven/essercoe [tentofJrittion than,lSiM DII6 roofingfeltinatlry[antlltion, teabolMstontlaM laboraw, wnditions. Agreement between purchaser Rod seller. m setforth in Section 4.3, Note I ofASTM D197615, should be established m to slip resetance. NEMO ETC, LLC. Ewluation Report P12060.02.09-RZ7 Cem/lmte/AUN,nNcnnn MOM 7r"EDITION (2020) FRC NON HVHZ EVALUATION FL5259-1131 Polyglass Roof Underlayments Revision 27: 09/30/2020 Page 4 of 17 ONEM(Djetc. 5.6 Allowable Roof Covers: TABLE I: RoOFCOVEROPTIONS Asphalt Clay and Concrete The Metal Slate or woad Undedayment Shingles (1503.3) Slate -Type Mechanical Adhesive- Panels Shingles shingles Shingles (3soz21 shakes rysms) Attach set lLwxq (If0251 (asP).>) pSW.g) Yes Yes Yes Yes Yes Yes Yes Yes Elastobase (xv.n 1. Went w. Iuu.eeneu, une.naum Veron .t. une.nelo Wlenmemou6 Wnemm.iooua, oxxRixyeul sn,.1 '++sat) ovk Ynn,", sn"noIs) eatATtT+e1 rnR xa ryxvl Yes Yes Yes Yes Yes Yes Yes Yes ElastabaseP Wemal.l. Wurzm.n Wu.. sneer W.m>.. Wunm (.n. WInax"con', hueleaumona, M36. T..III t 1all see S.1) ono rip 1p @$TtAlp oxl4 im.n) Ttu 11) TA." Yes Yes POlyglass Base N0 P. ease sn.ex Wux sn.n, No No No No No YYes Yes POlyglass G2 Base No la+eaes onat.ue, No No No No No t..s.0 s.. s3.s1 ElastoRe%SISG No Yes Yes No No No No No ISee5.6.11 Ela$toflex S6 G FR No Yes No No No No No No Yes Yes HydraGuard Dual Pro Yes No No Yes Yes Yes Ummmim.nozlu Ueaamn,,asot.i..' /R9V+vld1 /ates.s..31 Yes Yes Yes HydraGuard Tile Pro Yes Yes (see s.¢U Yes Yes Yes I\ a'Un,mnu. sysex Raom].. /xICAL131 /xice.Lv1 Mule -Hide SA-APP Cap Sheet No Yes Yes No No No No No (Se Mule -Hide SA-APP Cap Sheet (FR) No Yes No No No No No IseYes.il PolygexG No Yes Yes No No No No N0 I (See SX..I POlyvex G FR No Yes No No No No No No POIyNex SAP No Yes Yes No No No No No (lee B.6.11 PolyRex SA P FR No Yes Yes No No No No No (sees 6.1) Yes Yes Polystick lR-Xe Yes No No No No Yes ygntrvlpxuot.vl.a W.'Mw,sem.1. /MM11.31 I /Atle.L.) Yes Vm Polystick MTS Plus Yes Yes No Yes Yes Yes OumuM lsm.m Ilounwgx aunt] /xM.LLa) /aW5.1..' Yes Yes Polystick MU-X Yes No No Yes Yes Yes U.xuwq.txA.t]] 0.Im AnA'ese.1.13 /x9n,,I IJtYes /Raae.l.l31 Yes Yes Polystick TU Max No Yes (.a 5.6.11 Yes Yes No 6AxasOS]. iN�u.. uso'1 golmao-plasmt]3 /Rrw /x955].131 Yet es Y(see Yes Polystick TUP No Yes SA.11 No No No Ue"no"i,. Udm Rasn,wo`. /wm.t131 /xmll..) Yes s Yes Palystick TU Plus Yet Yes ($,156.1) Yes Yes Yes gdmerlp; lwzl. Ummnnm, asm.ua IemaLt) /Mm3..I Yes Yes Polystick XFR Yes Yes No Yes Yes Yes lymmlq,.7.1. linen LIIolv3 /pm.s331 Isom.,..) NEMO ETC, LUC. Evaluation Report P12060.01.09-R22 Cetroon cal,hrboi+otlnn#32055 7- EDITION (2020) FSC NON-HVH2 EVALUATION FL1259-R31 P.I,I... goof Underlayments RIVIsIOn 27:09/30/2020 Page 5of 17 NNEMOjetc. 5.6.1 Adhesive -set tile is limited to use of the following underlayment/tile-adhesive combinations. TABLE IA: ALLOWABLE UNDERLAYMENT/ TILE-AOHtswe COMBINATIONS' Undedayment Adhesive Florida Product Approval Polystick TU Max or Polystick TU Plus DAP FOam"Touch 'n Seal FL14506 StormBoad Roof Tile Adhesive" HydraGuard Tide Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick Dupont Tile Bond'" Hoof Tile FU2525 TU Plus Adhesive" Elastoflex 56 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA- ICP Adhesives and Sealants APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, "polyset• AH-160" FL6332 Polystick TU P or Polystick TU Plus Elastoflex 56 G, HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet, Mule -Hide SA- ICP Adhesives and Sealants APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, •polyset•ivesan FL6276 Polystick TU P or Polystick TU Plus 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERIAYMENTS Substrates (designed to meet wind loads for project) Undedayment Application Type Printer Matedai(s) HydraGuard Dual Pro, (Optional)ASTM plywood,058, Southern Yellow Pine or Huber Engineered HydraGuard Tile Pro, Polystick IR- Deck D41 Woods" ZIP System- Panels Xe, Polystick MTS Plus, Polystick sheathing ASTM D41 structural concrete MU-X, Polystick TU Max, self- ASTM C1289 Type II Class 1 polyisocyanurate, ASTM Polystick TU P, Polystick TU Plus, adhering Insulation (Optional)ASTM C1289 Type V polyisocyanumtecomposite,DensDeck Polystick XFR, Mule -Hide SA-APP 041 or WB-3000 Prime or SECUROCK Gypsum -Fiber Root Board Cap Sheet Mule -Hide SA-APP Cap Sheet (FIR), Polyflex SA P or Base Sheet N/A ASTM D226, Type II felt, Elastobase, Elastobase P or Mule. Polyflex SA P FR I Hide Nail Base Deck ASTM 041 structural concrete Insulation (Optional)ASTM DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board Elastoflex SG G or Elastoflex S6 G hot asphalt D41 FR ASTM D226, Type II felt, Elastobase, Elastobase P, Mule - Base Sheet N/A Hide Nail Base or Polyglass G2 Base Deck ASTM D41 structural concrete Insulation (Optional)ASTM DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board torch- Polyflex G or Polyflex G FR applied D41 Base Sheet N/A Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass Base 2 Refer to Tile Manufacturer's co -Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC. Evaluation Report P32060.02.09-R27 Cem/k•teo/AUtMtlmt1onp31455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FI5259-R31 Polyglass Roof Underlayments Ralston 27:09/3012020 Page 6 of 17 ONEMOletc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturers installation instructions, but— for mechanically attached undedayments or base sheets - not less than FBC 1S07.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturers installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High WindConcrere and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,Table l(forTwo- Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/FRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table lA or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure=-52.5 psf: Deck: APArated,7/16CAT,0.418 in., Exposure 1, OSBsheathingto meet project requirementsto satisfaction of Authority Having Jurisdiction. Joints: Min. 4-Inch wide strips of Elastoflex SA-V aver all OSB joints Base Ply: Polystick MTS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polysdck TU Max, Polystick TU P or Polystick TU Plus, self -adhered. R2 Maximum Design Pressure =-90 osf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FIR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. 93 Maximum Design Pressure=-97.5 osf: Deck: MIn.15/324rch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PGI00 or ASTM D41 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x lY." ring shank nails through 32 ga.,1-5/8" diameter tin raps spaced 12-inch o.c. g4 Maximum Design Pressure =-105 osf: Deck: MIn.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x lY' Ong shank nails through 32 Be., 1-5/e" diameter tin caps spaced 12-inch o.c. NEMO ETC, L-C. Evaluation Report P32060.02.09-1117 Cif to alAudow ton e32a55 7-EDITION OOZO) FBC NON HVHZ EVALUATION FI5259-1131 Polyglass Roof Underlayments Reuiidim 27: 09/30/1020 Page 7 of 17 ONEMOletc. 05 Maximum Design Pressure=-135 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG1W or ASTM D41 Base Ply: (Optional) Polystick NITS Plus, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Mule -Hide SA-APP tap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. R6 Maximum Design Pressure=-315 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick NITS Plus, self -adhered. Underlayment HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet ER), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. g7 Maximum Design Pressure=-622.5 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG300 or ASTM D41 Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. R8 All other direct -deck, adhered Underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf. 5.8.3.2 Mechanically -Attached Base Sheet The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table SA or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RA5137. Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. d9 Maximum Design Pressure =-30.0 osf•: Deck: Min.15/32-Inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastabase or Mule -Hide Nail Base)poly-film top surface) Fasteners: 11 ga. x 1.15-Inch long x lArch head diameter round metal cap nails Spacing: &inch o.c. at the 3-inch wide side laps and&inch o.c.at me (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick NITS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. 010 Maximum Design Pressure = .37.5 osf : Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows. Base Ply; (Optional) Polystick NITS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. 1131 Maximum Design Pressure =-37.5 osf Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-Inch long x 1-inch head diameter round metal cap nails Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt. NEMO ETC, U.C. Evaluation Report P12060.02.09-R27 Certlflmre o)AuMmivexe#32455 7- EDITION (2020)FBC NON-HVHZ EVALUATION FL5259-1131 Polyglass Roof UnderlaVments Revision 27:09/30/2020 Page 8 of 17 NNEMO Ietc. 012 Maximum Design Pressure =-45 osf-: Deck: Min.19/32-Inch plywood to meet projectrequirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inchx3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch D.C. at the 2-Inch wide side laps and 4-inch D.C. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick NITS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #13 Maximum Design Pressure =-45 osf•: Deck: Min.19/32unch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Two (2) layers ASTM D226, Type ll felt Fasteners: 11 Be. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps Spacing: 9-inch D.C. at the 2-inch wide side laps and 9-inch D.C. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick NITS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered or ElastoFlex S6 G, applied in full mopping of hot asphalt. #14 Maximum Design Pressure=-45 Osf: Deck: Min.I5/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied Cap or poly -film surface fortorch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch D.C. at the 2-inch wide side laps and 18-inch out. at two (2) equally spaced staggered center rows. Underlayment ElastoFlex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #15 Maximum Design Pressure = -45.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/9" diameter tin caps Spacing: 6-Inch o.c. at the 3-inch wide side laps and 6-inch D.C. at four (4) equally spaced staggered center rows. Base Ply: (Optional( Polystick NITS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyfex SA P. Polyfex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #16 Maximum Design Pressure=-45.0 osf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB Sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (send top surface) Fasteners: 12 ga. annular ring shank nails with 1-5/8' diameter tin caps Spacing: 64nch D.C. at the 3-inch wide side laps and 6-inch D.C. at four (4) equally spaced staggered center rows. Underlayment ElastoFlex S6 G, applied in full mopping of hot asphalt. #17 Maximum Design Pressure = -45.0 DO: Deck: APA rated,7116 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch D.C. at four (4) equally spaced staggered center rows. Underlayment Polyflex G, torch -applied. #18 Maximum Design Pressure =-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAX% Cap Fasteners Spacing: 9-inch O.C. at the 2-inch wide side laps and 12-inch D.C. at two (2) equally spaced staggered center rows. Underlayment Elasto8ex S6 G, applied in full mopping of hot asphalt 0r Polyflex G, torch -applied. NEMO ETC, LLC, Evaluallan Report P12060.01.09-1127 CeTfiwrco/AuflwrWCon p32155 lam EDITION 12020)FBC NON-HVHZ EVALUATION FB259 R31 Polyglass Roof Ondedayments Revision 27: 09/30/2020 Page 9 of 17 ONEMOJetc. H19 Maximum Design Pressure =-52.5 its Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-Inch o.c. at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick NITS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polysdck TU Max, Polystick TU P or Polystick TV Plus, self -adhered. N20 Maximum Design Pressure =.52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap No Its Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Underlayment Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure =-60 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having lurisdiction. Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-inch tong x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment Elastoflex 56 G, applied in ful I mopping of hot asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure =.60 psf Deck: Min.19/32Anch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG#12 Standard Roc ip with OMG Flat Bottom Metal Plates Spacing: 12-Inch o.c. at the 4dnch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #23 Maximum Design Pressure =-60.0 osf: Deck: APA rated, 7116 CAT, 0.418 In., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (ply -film top surface) Fasteners: Simplex MAX% Cap Fasteners Spacing: 8-Inch o.c. at the 3-Inch wide side laps and 8-Inch o.c. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TV P or Polystick TV Plus, self -adhered. #24 Maximum Design Pressure =-60.0 psf: Deck: APA reted,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-Inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex SG G, applied in full mopping of hot asphalt. 025 Maximum Design Pressure = -60.0 psf: Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 8-inch o.c. at the 3-Inch wide side laps and I inch o.c. at three (3) equally spaced staggered center rows. Underlayment Polyflex G, torch -applied. NEMO ETC, LLC. Evaluation Report P32060.02.09-R27 Cert4lmte ufaudur0etlun#32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R31 Polyglass Roof UndedaymeMs Revision 27:09/30/2020 Page 10 or 17 NNEMOletc. #26 Maximum Design Pressure = -67.5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base (requires use oftorch-opplied underfayment) Fasteners: 12 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps Spacing: 8-Inch o.c. at the 4-Inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #27 Maximum Design Pressure=-67.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180* into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-Inch o.c. at the 4-Inch wide side laps and 12-Inch Oc. at two (2) equally spaced staggered center rows. Primer: (Optional) PG 100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick NITS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polvflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. 928 Maximum Design Pressure =-67.S osf: Deck: APA rated, 19/32 CAT, 0,578 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand tap surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180'into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-Inch wide side laps and 12-inch o.c. at two (21 equally spaced staggered center rows. Underlayment Elastoflex 56 G, applied in full mopping of hot asphalt. #29 Maximum Design Pressure =-67.5 osf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, O5B sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' Into the holes of the plate, parallel to the width direction of the sheet. Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows. Underlayment Polynex G, torch -applied. #30 Maximum Design Pressure=-75 osf: Deck: MIn.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base frequlres use cftorchopplied underlayment) Fasteners: Dekfxt#14 with Dekfast Hex plates, OMG #14 HD with OMG 3' Galvalume Steel Plates, OMG Roofgdp#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Tmfast 3-inch Insulation Plates or Simplex MAU Cap Fasteners Spacing: 30-Inch o.c. at the 4-Inch wide side laps and 30-Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex 56 G, applied In full mapping of hot asphalt ortorch-applled or Polyflex G, torch -applied. #31 Maximum Design Pressure =-90 psf: Deck: MIn.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded cep surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAU Cap Fasteners Spacing: 6-inch o.c. at the 2-Inch wide side laps and&inch o.c.attwo (2) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #32 Maximum Design Pressure =.90 psf: Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cep) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or DIMS flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R27 RM)¢oteojautlwtlmtbn.32151 7' EDITION (20201 FBC NON-HVHZ EVALUATION R5259-R31 Polyglass RPof Undedayments Revision 27: 09/30/2020 Page 11 of 17 NNEMOletc. #33 Maximum Design Pressure =-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt. #34 Maximum Design Pressure =-90 nsf: Deck: Min. 1S/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base frequires use ofearchmpplied underlayment/ Fasteners: Dekfast#14 with Dekfast Hex plates, OMG H14 HD with OMG 3" Galvalume Steel Plates, OMG Roofil#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAxx Cap Fasteners Spacing: 9-inch o.c. at the 4-Inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied. #35 Maximum Design Pressure=-90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Junsdiction. Base Sheet Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180' Into the holes of the plate, parallel to the width-chrection of the sheet Spacing: 9-Inch o.c. at the 2-inch wide side laps and 12-inch cre. at two (2) equally spaced staggered center rows. Primer. PGIOD or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #36 Maximum Design Pressure=-90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 In., Exposure 1, OSB sheathing to meet projectrequirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate Installed 180' into the holes of the plate, parallel to the width -direction of the sheet Spacing: 9-Inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment Elastoflex S6 G, applied In full mopping of hot asphalt. #37 Maximum Design Pressure=-90.0 psf: Deck: APA rated, 7/16 CAT, 0.418 In., Exposure 1, OSB Sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the hales of the plate, parallel to the widthdiredion of the sheet Spacing: 9-Inch o.c. at the 2-inch wide side laps and 12-Inch o.c. at two (21 equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #38 Maximum Design Pressure =-97.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet. Elastobase or Mule -Hide Nall Base (poly -film top surface) Fasteners: 11 ga. x 1.25-Inch x 3/8-Inch head diameter annular ring shank roofing nails at 1.5/84ch diameter tin caps Spacing: 4-Inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. NEMO ETC, LLQ Eualuatlon Report P3Z060.02.09-R27 Cvrlftwreo1Au0vUvdaa032455 7- EDITION (2020) Fee NON-HVHZ EVALUATION FL5259-1131 Polyglass Roof UndeHayments Revision 27:09/3012020 Page 12 of 17 NNEMOletc. #39 Maximum Design Pressure=-97.5 Pst: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base(poly-fllm top surface) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASfM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), PolyBex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #40 Maximum Design Pressure =-97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand tap surface) Fasteners: Simplex MAXX Cap Fasteners Sparing: 6-Inch oa, at the 4-Inch wide side laps and 6-Inch o.c. at four (41 equally spaced staggered center rows. Underlayment: ElastoRex 56 G, applied in full mopping of hot asphalt. #41 Maximum Design Pressure =.97.5 psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch Oc. at the 4-inch wide side laps and 6-inch Oc. at four (4) equally spaced staggered center rows. Underlayment Polynex G, torch -applied. 942 Maximum Design Pressure =-105 psf: Deck: Min.15/32-Inch plywood t0 meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch ox. at the 2-Inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows. Undedayment: ElastoRex 56 G, applied In full mopping of hot asphalt or PDlyfiex G, torch -applied. 043 Maximum Design Pressure=-105.0 psf: Deck: APA rated,7/16 CRT, 0.418 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa -Fast Fasteners &Plates with two screws per plate installed 1804 into the holes of the plate, parallel to the width -direction of the sheet Spacing: &inch o.c. at the 4-Inch wide side laps and 6-inch Oc. at three (3) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRj, Polyfiex SA P, POlyfiex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #44 Maximum Design Pressure=-105.0 psf: Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -fast Fasteners & Plates with two (2) screws per plate installed 180' into the hales Of the plate, parallel to the width -direction of the sheet Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: ElastoOex S6 G, applied in full mapping of hot asphalt. NEMO ETC, U.C. Evaluation Report P12060.01.09-R27 Cen111mr, Of AutM1ONotlan#114SS 7- EDITION (2020) FBC NON-HVH2 EVALUATION F1.5259-1131 Polyglass Roof Undedayments Revision 27: 09/30/2020 Page 13 of 17 NNEMOletc. #45 Maximum Design Pressure=-105.0 Dsf: Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase Or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two screws per plate Installed 180' into the holes of the plate, parallel to the width -direction Of the sheet Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c- at three (3) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. #46 Maximum Design Pressure=-112.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga.x 1.25-inchx3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Primer: PG 100 or ASTM D41 primer at all tin -ups Base Ply: Polystick NITS Plus, seltUadhered Underlayment: Mule -Hide WARP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #47 Maximum Design Pressure=-120 psf: Deck: Min. 35/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase(sanded tap surface for hot -asphalt or torch -applied cap or poly- film surface for torch -applied tap) Fasteners: OMG #12 Standard ROOfgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or DING Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment Elostoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #48 Maximum Design Pressure=-120 Dsf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at five (5) equally spaced staggered center rows. Underlayment Elasroflex S6 G, applied in full mopping of hot asphalt. #49 Maximum Design Pressure=-127.5 of : Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction Of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base(poly-film tap surface) Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #50 Maximum Design Pressure = -127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sand top surface) Fasteners: TRUFAST Versa -Fart Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-Inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elasroflex S6 G, applied in full mopping of hot asphalt. #51 Maximum Design Pressure=-127.5 psf: Deck: APA rated, 19/32 CAT, 0.578 In., Exposure 1, OSB sheathing t0 meet project requirements t0 satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa -Fast Fasteners&Plates with one (1) screw per plate, in the center hole. Spacing: 9-Inch o.c. at the 4-inch wide side laps and 9-Inch o.c. at four (4) equally spared staggered center rows. Underlayment Polynex G, torch -applied. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-f137 Gorfrt of Authoriodor#32435 7-EDITION JZ0ZO)FBC NON-HVHZ EVALUATION F15259-1131 PoWass Roof Undedaymems Revision 27:09130/20ZO Page 14 of 17 NNEMOjetc. 5.9 Exposure Limitations: TABLE3: EXPOSURELimmATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure(days) Elastobase, Elastobase P, Painless G2 Base or Polyglass Base Mechanically attached 30 Polystick lR-Xe or Polystick MU-X Mechanically attached 90 HydraGuard Dual Pro, HydraGuard Tile Pm, Polystick MIS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR Any type (per Table l) ISO Eleano0ex S6 G, Elastollex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Poly0ex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR Adhesive -set tile roof system ISO Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the maximumroof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE4: TRESUPPAGE LIMRATIONS MR DIRECT-DECXTILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Staging Slope ElastoRex S6 G or S6 G FR Flat or Lugged 6-tile stack III over 2) Prohibited without battens HydraGuard Tile Pm Flat or Lugged 6-tile stack is over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack i4 over 2) 4:12 Polystick NITS Plus Flat 6-tile stack(4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack(4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TUP Flat or Lugged 6-tile stack(4 over 2) 7:12 Polystick TU Plus Flat or Lugged 6-tile stack III Over 2) 7:12 Flat .,Lugged 10-tile stack 6:12 Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens NEMO ETC, U.C. Evaluation Report P12000.02.09-R27 rirtllkateafAuthodevelona37455 7- EDITION (2020) FaC NON-HVHZ EVALUATION F15259-1131 Polyglass Roof underlayments Revision 27: 09/30/2020 Page 15 of 17 ONEMOjetc. Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be Installed, and the manufacturer's Installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. Elastobase, Elastobase P or Mule -tilde Nall Base may be covered with a layer of Polystick IR-Xe, Polystick NITS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex 56 G or Elastoflex 56 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: 6.3.2.1 Elastobase (poly-fllm top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the -MO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay RaofTile Installation Manual, Sixth Edition, followed by Polystick MTS Plus, Polystick TU Max, PolystickTU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SAP FR, MuIe-HIde SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR,torch-applied. Tile roof Installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for attachment requirements. 6.3.2.2 Elastobase (sanded -top) and Elastobase P(sanded-top)e are limited to use as a mechanically attached base sheet in the `TM/0- PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by Elastoflex S6 G, Elastoflex 56 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex G or Polyflex G FR. torch -applied. Tile roof Installation method is limited by the selected Cap Sheet, as set forth in Table 1. • When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex 56 G, Elastoflex 56 G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/I-RI, Sixth Edition, Appendix A, Table 1 or Section 5.8.3.2 herein for attachment requirements. • When Elastobase (sanded -top) or Elastobase P(sanded-top) is followed by torch -applied Polyflex G or Polyflex G FR, refer to Section 5.8.3.2 herein for attachment requirements. 6.4 HydraGuard Dual Pro, HVdraGuard Tile Pro, MuIe-Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick IR-Xe, Polystick NITS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR: 6.4.1 General: All seal -lap seams (selvage laps) must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric(. View of creep Seam of HydraGuard Dual Pro and HydraGuard The Pro NEMO ETC U.C. Evaluarlon Rep.N P32060.02.09-RZ7 Onme ne efAutho@otion#32a55 Tr°EDITION (2020) Fee NON-HVHZ EVALUATION FL5159-R31 Polyglass Roof Underlayments R.Won 27:09/3012020 Page 16 of 17 NNEMOjetc. 6.4.2 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.2.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be Installed, and the manufacturer's installation instructions. When Installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase, Elastobase P or Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.3 Tile Applications (excludes HydraGuard Dual Pro. Polystick lR-Xe and Polystick MU-X): Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.4.4 Multi -Ply Underlavment Svsteme: Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro, PolyRex SA P, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR Is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This Is not a requirement, but is allowable if a 2-ply underlayment system Is desired, Polystick MTS Plus followed by HydraGuard Tile Pro, Polyfiex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not requirement, but Is allowable if a 2-ply underlayment system is desired. 6.5 Elastoflex S5 G or ElastoRex S6 G FR: 6.5.1 Shall be Installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation Instructions. Refer to Section 5.8.2 and S.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.6 PolyRex G or PolyRex G FR: 6.6.2 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" In the "Two Ply System" In the FRSA/TRI Florida High Wind Concrete and Cloy Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for the staging limitations. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PUNTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. P . UL LLC — CUA9625; (414) 248-6409; Karen.buchmann(dul.com END OF EVALUATION REPORT - NEMO ETC, LLC. Evaluation Repart P32060.02.09-R27 con,flmttal<uftnanon.32455 7"EDITION (2020)FBC NON-HVH2 EVALUATION F1.5259-R31 Po1vg1as5 Roof Unduruvo ents Revlslon 27; 09/30/202D Page 17 of 17