HomeMy WebLinkAboutCreekside Lot compactiono���NTr� • cFol�Os
g 2Universal
w
m
02Sciences
G
9`S TFSTING'Company
•
UES Project No: 3360.1800067.0000
Workorder No: 240943-1
Report Date: 08/02/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician: Mark Rogers
1430 Culver Drive, NE Date Tested: 07/30/2021
Palm Bay, FL 32907
Project: CMT CREEKSIDE
Yorktown Drive & Okeechobee Road,Fort Pierce, St Lucie County, FL
Area Tested: Lot 115 , 9400 Potomac Drive, Ft. Pierce
Material: Backfill
Reference Datum: 0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Northeast corner of lot
0-1 ft
118.6
10.8
114.3
10.5
96
Pass
2
Southwest corner of lot
0-1 ft
118.6
10.8
114.8
10.6
97
Pass
3
Center of lot
0-1 ft
118.6
10.8
114.1
10.6
96
Pass
Remarks: Permit:2103-0842
The in -place density tests were performed within the foundation/
Reviewed By
building pad footprint of the referenced residential lot. The test
GFA International, Inc
FBPE Registry No.4930
results either meet or exceed the requirements of the FHA/HUD
oyiNc,
Digitally signed by
manual and the current edition of the Florida Building Code for soil
;
compaction. The Contractor is responsible for maintaining the tested
BPS°OMENSeMONr
_°:' C?o';
Thomas D
soil subgrade in the same condition that existed at the time UES
-*: "O84'46 *=
:��=
Montano:A014100000001
performed the referenced density tests. UES is not responsible if the
�..
O '., STA E OF �[
7818498DCD000019A3
tested area is altered from the approved condition at the time of
=, ��.F,(O...... �G\�;�
',,` 1/O A1- E,�`'
Date: 2021.08.02 14:18:59
testing.
11 ""'\
-04'00'
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
This item has been digitally signed and sealed by Thomas Dominic
Montano on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1