Loading...
HomeMy WebLinkAboutAPPROVED Fuel.Gas - Karen Allen - 4701 Eagle Dr, Fort Pierce, FL 34951 --SUPPORTING DOCSCopyright 2019 Nalinnal Fire Pnetactiorn Association (NF-PAf:)). Licensed by agreement to Toot Fite FOR INDIVIDUAL USE ONLY and downloaded on 1211 V2019. No reproduction or hansmission in any form permitted wiliiout wr+lten permission of NFPAV. For inquiries or access for mwiliple users, or to report unauthorized use, contact licensinq(q)nfpa.org. PIPE AND TUBING SIZING TABLES 58-105 A Table 16.1(c) Schedule 40 Metallic Pipe Undiluted Inlet Pressure: 11.0 in. w c. Pressure Drop: 0.5 in. w c. pecific Gravity: 1.50 OffENDED USE: Pipe Sizing Between Single- or Second -Stage (Low -Pressure) Regulator and Appliance. Pipe Size (in.) Nominal: V2 s/4 I 1 %4 1'/s 1 2 2 /s 3 4 Actual: 0.622 0.824 1.049 I.380 1.610 1 2.067 2.469 3.068 4.026 Length (£t) Capacity in Thousands of Btu per Hour 10 291 608 1,150 2,350 3,520 6,790 10,800 19,100 39,000 20 200 418 787 1,620 2,420 4,660 7,430 13,100 26,800 30 160 336 632 1,300 1,940 3,750 5,970 10,600 21,500 40 137 287 541 1,110 1,660 3,210 5,I10 9,030 18,400 50 122 255 480 985 1,480 2,840 4,530 8,000 16,300 60 110 231 434 892 1,340 2,570 4,100 7,250 14,800 80 101 212 400 821 1,230 2,370 3,770 6,670 13,600 100 94 197 372 763 1,140 2,200 3,510 6,210 12,700 125 89 185 349 716 1,070 2,070 3,290 5,820 11,900 150 84 175 330 677 1,010 1,950 3,110 5,500 11,200 175 74 155 292 600 899 1,730 2,760 4,880 9,950 200 67 140 265 543 814 1,570 2,500 4,420 9,010 250 62 129 243 500 749 1,440 2,300 4,060 8,290 300 58 120 227 465 697 1,340 2,140 3,780 7,710 350 51 107 201 412 618 1,190 1,900 3,350 6,840 400 46 97 182 373 560 1,080 1,720 3,040 6,190 450 42 89 167 344 515 991 1,580 2,790 5,700 500 40 83 156 320 479 922 1,470 2,600 5,300 550 37 78 146 300 449 865 1,380 2,440 4,970 600 35 73 138 283 424 817 1,300 2,300 4,700 650 33 70 131 269 403 776 1,240 2,190 4,460 700 32 66 125 257 385 741 1,180 2,090 4,260 750 30 64 120 246 368 709 1,130 2,000 4,080 800 29 61 115 236 354 681 1,090 1,920 3,920 850 28 59 111 227 341 656 1,050 1,850 3,770 900 27 57 107 220 329 634 1,010 1,790 3,640 950 26 55 104 213 319 613 978 1,730 3,530 1,000 25 53 100 206 309 595 948 1,680 3,420 1,100 25 52 97 200 300 578 921 1,630 3,320 1,200 24 50 95 195 292 562 895 1,580 3,230 1,300 23 48 90 185 277 534 850 1,500 3,070 1,400 22 46 86 176 264 509 811 1,430 2,930 1,500 21 44 82 169 253 487 777 1,370 2,800 1,600 20 42 79 162 243 468 746 1,320 2,690 1,700 19 40 76 156 234 451 719 1,270 2,590 1,800 19 39 74 151 226 436 694 1,230 2,500 1,900 18 38 71 146 219 422 672 1,190 2,420 2,000 18 1 37 69 142 212 409 652 1,150 2,350 Note: All table entries are rounded to 3 significant digits. [54:Table 6.8.1(d)] Shaded text = Revisions. A = Text deletions and figure/table revisions. • = Section deletions. N = New rnateriai. 2020 Edition Copyright 2019 Nahorral Fire Protection Association (NFPA®). Licensed by agreement to Tom Fite FOR INDIVIDUAL USE ONLY and downloaded on 1211112019. No reproduction or transmission in any form permitted w1hout written permission of NFPA®. For inquiries or access for multiple users, or to report unauthorized use, contact Iicensin9Qnipa.arg. PIPE AND TUBING SIZING TABLES 58-113 Table 16.1(k) Corrugated Stainless Steel Tubing (CSST) Undiluted Inlet Pressure: 11.0 in. w.c. Pressure Drop: 0.5 in. w.c. Specific Gravity: 1.50 INTENDED USE: CSST Sizing Between Single- or Second -Stage (Low -Pressure) Regulator and Appliance Shutoff Valve. Tube Size (EHD) Nominal Size: 8�8„ 8/8„ 1�2r, 112„ 3X4n 9/419 1 11 1, 1V411 It/4,f 1112n 11/211 21' 211 Flow Designation: 13 15 18 19 23 25 30 31 37 39 46 48 60 62 Length (ft) Capacity in 'Thousands of Stu per Hour 5 72 99 181 211 355 426 744 863 1,420 1,638 2,830 3,270 5,780 6,550 10 50 69 129 150 254 303 521 605 971 1,179 1,990 2,320 4,110 4,640 15 39 55 104 121 208 248 422 490 775 972 1,620 1,900 3,370 3,790 20 34 49 91 106 183 216 365 425 661 847 1,400 1,650 2,930 3,290 25 30 42 82 94 164 192 325 379 583 762 1,250 1,480 2,630 2,940 30 28 39 74 87 151 177 297 344 528 698 1,140 1,350 2,400 2,680 40 23 33 64 74 131 153 256 297 449 610 988 1,170 2,090 2,330 50 20 30 58 66 118 137 227 265 397 548 884 1,050 1,870 2,080 60 19 26 53 60 107 126 207 241 359 502 805 961 1,710 1,900 70 17 25 49 57 99 117 191 222 330 466 745 890 1,590 1,760 80 15 23 45 52 94 109 178 208 307 438 696 833 1,490 1,650 90 15 22 44 50 90 102 169 197 286 414 656 787 1,400 1,550 100 14 20 41 47 85 98 159 186 270 393 621 746 1,330 1,480 150 11 15 31 36 66 75 123 143 217 324 506 611 1,090 1,210 200 9 14 28 33 60 69 112 129 183 283 438 531 948 1,050 250 8 12 25 30 53 61 99 117 163 254 390 476 850 934 300 1 8 11 23 26 50 1 57 90 107 147 234 1 357 1 434 1 777 854 EHD: Equivalent hydraulic diameter. A measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing. Notes: (1) 'fable includes losses for four 90 degree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation; L = 1.3n, where L is additional length (ft) of tubing and n is the number of additional fittings and/or bends. (2) All table entries are rounded to 3 significant digits. Shaded text = Revisions. A = Text deletions and figure/table revisions. • = Section deletions. N =blew material. 2020 Edition 0 325.31. 1 r� - �, fig. 32S 5L-1 325.31.48 Aw iniftol 325 Series Regulators 325 Series pounds to inches regulators are for use on residential, commercial, and Industrial applications. The 325 Series features a high leverage valve linkage assembly to deliver positive riead-end lock -up. The regulators are capable of Precise regulating control from full flow down to pilot flow. U odelst Imblue TechnologyrM increases corroslon resistance and provides extra protection against the elements for regulators used In outdoor applications, PARE NUM13ER INSIDEVr-.NT I-IMIi'Ufi INUT{C7VGMCz1'.OUT'.510N'VG:N1 CONNEt„fiCJN PROTECTOR SETTING W SPRING SPRING RANGE 8TUCAPPACITYWITH SINOIXAirPLAANCE STUCAPA�crrYAU. APFLIANC)ESCOMBINP 3253 12AO9 3/8� m — 1a`_A15_ li_W;C� 711_W'.0 140,000 250,bOQ 325l,3Ly 12A09 1/'1_" 13A15 '11" W.0 7.11 WC 140,000 250,000� 325-IBL 12A09 1/2' � - 18A15 -' 11 W_O 711'WC 250000 325.5L 12A39 �3/4, 13A15-5_ - 'I I," f"W 7.1ri3O _ _140,00_0 300,000� - _. 600,000 326 5L 1 '12A'39 ' 1 18A15_ 5 _ 1V W!0 71 I' W.0 300 000 6 {J'p00 V 325.51,1W, 12A39 _ 1/2" 13A15.5 11" W,C 7.1 I 11 W.0 300,000 600,000 325-58L 12A39 3/4"� 13A15.5 I1"WiC 7.11' W.0 300000 4� 550;000 u1,260,000 325-71, 12A49 1/4" 1MM 11" WIC Mill W.0 ' 1,260,000 325.7BL 12.A49 -~ 1.1/4" 13A25 . li"W:C 7-11"KC 1,250,000 1,?50,000 4 xit3•ol Regill l OPD The 325 Series with OPgs flea inres a high leverage valve linkage assembly to deliver positive dead-end lock -up. The regulators are capable of precise regulating control from full flow down to p1lol: flow, PART NUMBBR� .M•C7PI3 TYPE INLETIOUTICT "3ETrING �... CONNECTION OF SPRING SPRING RANGE BrU CAPACITY WITH-1 kD7U CA6�ACI7VAl.1_ SMILE APPLIANCE' APPI IANCLS COMBINED 325.3L48 w/OPO 48 attached 1/2" 11 W C 7.11 W.C. , 200'000 325.51.48_ w/OPO_48 attached 3/4' 11 W C 7.11" W.C. 235,000 325 5C600 3/4 ,w/OPO 600 attached 3/4 -^- "` 11 W.0 7-11 W.0 425;000 -- lJ