HomeMy WebLinkAboutCertificate for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Wolf Lube LLC Warehouse and Offices
Project Name:
Project Address:
Post Office Circle
Permit #: Occupancy Type: S-1 WH/offs Construction Type: I lb, Spr
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Sixth Edition with 2019 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed X Open
3. Risk Category: I X II III IV Exposure Category: B X C D
4. Design Wind Velocity I mph ASD X LRFD End Zone Width: 10' ft
5. Mean Roof Height 30' ft Roof Pitch: 1 /2 :12 Parapet: 3 ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 122.6-55.8Zone 222.E-95.5 Zone 3: 22.6-140.7Zone 455.8-60.5 Zone 555.8-76.5 Garage:._
7. Design Loads: Floor: 50/125 PSF Roof/Dead: PSF Roof/Live: Balcony: N/A PSF
N/A N/A 100 250#
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? NO Yes Not Applicable Explain Why Not:
Pre-engineered steel structure, 3-pin arch & cable stay MWFRS, _
9. Is A Continuous Load Path Provided?" Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply wit @I'cable structural portions of the building codes currently adopted and enforced by St. Lucie
Counil .. ucturai elements depicted on these plans provide adequate resistance to the design
John M. Foster
Print Name Cert # & Co. Cert Auth.
John M. Foster - Architect
e, and s®al.�� 11205 Ridge Ave., Ft. Pierce, FL 34983
D ARG� Company Name & Address
Revised 12/07/2018