Loading...
HomeMy WebLinkAboutProduct Approval; Roll-Up Exterior Door AssembliesFlorida Building Code Online 12/18120, 4:43 AM N.mom BCIS Home Log In ( User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search I Product Approval pr SER: Public User ka Product Aoproval Menu > Product or Application Search > Application Llst > Application Detail FL # L15918-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer ASTA DOOR CORPORATION Address/Phone/Email 55E\ISTR L DRIVE NW ACWORTH, GA 30101 (770)974-2600 Ext208 JFRENCH3@ASTADOOR.COM Authorized Signature JAMES FRENCH JFRENCH3 @ASTADOOR.COM Technical Representative James French Address/Phone/Email po box 42D acworth, GA 30101 jfrench3@astadoorcom Quality Assurance Representative Alan Peyton Address/Phone/Email Asta Door Corporation 4255 McEver Industrial Drive Acworth, GA 30101 (770)974-2600 Ext226 apeyton@astadoorcom Category =Exterior Subcategory Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C) Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Joseph H. Dixon, Jr. P.E. Evaluation Report Florida License PE-7768 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2020 Validated By Gordon Thomas, P.E. E4 Validation Checklist - Hardcopy Received Certificate of Independence FL15918 R3 COI_32022 Cert Rnan Indeo.odf FL15918 R3 COI Cert of Ind Scates 2017 s.odf Referenced Standard and Year (of Standard) Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E330 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect https://floridabu1lding.org/prlpr_app dti.aspx?param=wGEVXQwtDgsDdFYerPiwHNAKosm%2fFQHbp7u2lDXed7c%2fkcAPIGL3EA%3d%3d Page 1 of 3 •,. Florida Building Code Online 12/18/20, 4:43 AM 11\ FL15918 R3 Eouiv Equivalence of Standards Asta s.odf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/15/2017 Date Pending FBC Approval 10/18/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 15918.1 Models 203IM and 204IM Impact Windlock Maximum width, up to 14'0" wide. Maximum height up to 21'0" high. Commercial Sheet Door Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL15918 R3_1132022 Dwg Series 203IM 0002.12df FLIS918 R3 II 32022 Install Series 203IM 0004.odf Impact Resistant: Yes Verified By: Joseph H. Dixon, Jr. P.E. No. 7768 Design Pressure: +40/-40 Created by Independent Third Party: No Other: Evaluation Reports FLIS918 R3 AE_32022 ER-12-0003 0004,12df FL15918 R3 AE Affirm for FBC 6th 2017 15918 Asta s.pdf Created by Independent Third Party: Yes 15918.2 Models 422FIM, 420 FIM and 418FIM Maximum width up to 16'6" wide. Maximum height up to 30'0" high. Impact Rolling Steel Service Door Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS918 R3 II 32022 Dwg Series 400FIM 0002.odf HVHZ: Yes FLIS918 R3 II 32022 Install Series 400FIM and 600IM 0004.odf Verified By: Joseph H. Dixon, Jr. P.E. No. 7768 pact Resistant: Yes Design Pressure: +55/ 55 Created by Independent Third Party: No her: Evaluation Reports FL15918 R3 AE 32022 ER-12-0003 0004.12df FL15918 R3 AE Affirm for FBC 6th 2017 15918 Asta s.pdf Created by Independent Third Party: Yes 15918.3 Models 622IM, 620IM and 618IM Impact Maximum width up to 16'6" wide. Maximum height up to 30'0" high. Insulated Rolling Steel Service Door Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS918 R3_11 32022 Dwa Series 600IM 0002,yd Approved for use outside HVHZ: Yes FLIS918 R3 1132022 Install Series 400FIM and 600IM 0004.12df Impact Resistant: Yes Verified By: Joseph H. Dixon, Jr. P.E. No. 7768 Design Pressure: +50/-45 Created by Independent Third Party: No Other: Evaluation Reports + FL15918 R3 6E 32022 ER-12-0003 0004.pdf l FLIS918 AE Affirm for FBC 6th 2017 15918 Asta s.odf Created by Independent Third Party: Yes Bade Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must.provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click berg_. Product Approval Accepts: https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsDdFYerPlwHNAKosm"/"2fFQHbp7u2lDXed7c%2fkcAPIGL3EA%3d%3d Page 2 of 3 24 GA. HOOD IF li22, 20 OR 18 GAUGE GALVANIZED STEEL. GALVANIZED ACCORDING TO A.S.T.M. A653-G90 AND FINISHED WITH BAKED EPDXY PRIMER AND BAKED POLYESTER TOPCOAT (SEE NOTE 1) -SURE BOLT LOCK W r E" BRAWN ONE Co) EACH JAMB BOTTOM SST 515 NO SPACE (SEE NOTE #7) BULB ASTRAGAL N N 2w-xlo (Type) F4 rn STRUCTURAL STEEL ANGLE BOTTOM BAR 50 314' � � a `a R 0.09 co 6.06 3/16' 5/16' MATERIAL: CAST IRON %M—O K MAX. 12° TYP. 3' f Ix SIDE RVATM ST/�TE pF 0 vet ,� s+n •••owes•* cf 011,�ii 10%;00` FOR STEEL JAMBS. USE 1/2.13 x 1-12 SAE FOR CONCRETE JAMS. USE 1/2W GRACE BOLTS. ZINC PLATED, WITH HE)( EXPANSION BOLTS (MANUF. BY HEAD ZINC PLATED STEEL NUTS, AND ZINC PORTEOUS) WITH 2.1/4' MINIMUM PLATED STEEL WASHERS UNDER THE HEAD EMBEDMENT AND FASTENED 3' FROM AND NUT. FROM FLOOR, SPACE THE FIRST FLOOR AND SPACED p 12' ON BOLT AT T AND THEN AT 12' O.C. CENTER THERE AFTER THEREAFTER. ;USE 330W f51 617/8' CONCRETE51/4'IXISTING STEEL JAMB 3V16'MINIMUMTHICKNESS 31W-16 x 11/4'SAE GRADE BDLTS, ZINC PLATED.ITH HEX HEAD ZINC PLATED STEEL NUTS, AND 21NC PLATED STEEL WASHERS UNDER THE HEAD AND NUT. FROM FLOOR. SPACE THE FIRST BOLTAT 3' AND THEN 41/2„ � er a n n ru®eA— __ GAP NOT TO . \ `�E=1/4' POP RNETS PER WINDLOCK 5/8-SLIP.I `�-3 xZ'KVI6' TYP. EXCEED 1.12 \ PER S10£ ON ALTERNATING SLATS L3'x3.12k//4' TYP. 12'x3/4' STEEL BAR (SEE NOTE 2) GiUQE DETAIL AND DMENSM E 3 ••41 No. 7768 . 712' f�fy�y��.A��TppS1LpA^T`2y2��+ N P/ OR R �.1AUM 0 .s° 4255 McEver Industrial Dr. AcworttL GA 30101 974-1455 100 SEWS FIAT SLAT CERTIMD WINDLOAD AND WACT RATED ROOM STEEL. SERVICE DOOR TOLE mm ff-eW VH +!- 550 FRACTION = +1- 1 32 X = +/-.032 MODELS .XX = +/-.015 ELEMENT-ORLANDO .XXX - +/- .00S c -1-5 124 PREMIER ROAD 20FIM•20 GAUG LAND FL 2822 DRAWN BY: SCLLC%44Q"w-mrwTEST REPORT #ESP010181P ISSUE: 08.23-12 1 TEST DATES: 6/18/12 - 0/21/12 Summary of Welded Jamb Connections E-Guide to Steel Jamb Series Door ID I Slat gage Tested Door* 16,-6" wide i n Wind Load Job No. slipE1,11' in Fja^ pf ary lrlulpl P1nf catenary If Slot size all weld Weld in Scot OnlyWeld spacings are maximums"" in Slot plus Fillet Weld at Toe os sf Neg f min. 3116" Jamb 3116"iamb in slot only in slot I at toe 1/4" Standard Wall An e slot and toe welds staggered 400 AAM 420FIM 1 18 12 20 55.0 1 55.0 1 55.0 1 55.0 32022 0.625 0.625 2000 1 2000 2000 1 2000 9/16" x 3/4" 9/16, x 3/4, 1/4" fillet weld" 12' D.C. 1/4" fillet weld" 12" o.c. 114 x 1-1/2 12" O.C. 22 1 Test 1 55.0 1 55.0 0.625 2000 1 2000 9/16" x 3/4" 600 6181M 6201M 6221M 18 20 22 Test 50.0 50.0 50.0 45.0 45.0 45.0 32022 " 0.625 0.625 0.625 1881 1881 1881 1663 1663 1663 9/16" x 3/4" 9/16" x 3/4" 9/16" x 3!4" 1/4" fillet weld" 12 O.C. 1/4" fillet weld" 12" o.c. 1/4 x 1-1/2 12" D.C. ` doors tested with 1/2" bolts @ 12" o.c. connecting to 3116" steel jamb per drawing fillet weld around full perimeter of slot GENERALNOTES: "* no spacings exceed the fastener spacing of the test 1. STEEL USED FOR SLATS IS ASTM-A653 WITH MINIMUM YIELD OF 50 KSI AND TENSILE OF 60 KSI. 2. GUIDES COMPOSED OF STRUCTURAL STEEL ANGLES WITH MINIMUM .1875" THICKNESS. 3. THE WINDLOCKS ARE ATTACHED TO EVERY OTHER SLAT BEGINNING AT THE BOTTOM SLAT. WINDLOCKS ARE ATTACHED USING TWO -1/4" x 15/32" STEEL, ZINC PLATED RIVETS. 4. THIS DOOR HAS BEEN DESIGNED AND TESTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND THE INTERNATIONAL BUILDING CODE. THE DESIGN WIND PRESSURES REQUIRED FOR ANY DOOR SHALL BE DETERMINED USING THE APPROPRIATE SECTION OF THE CODE HAVING JURISDICTION WHERE THE BUILDING IS LOCATED. 5. THIS DOOR HAS BEEN SUCCESSFULLY TESTED TO: -THE UNIFORM STATIC AIR PRESSURE TEST PER ASTM E-330 AND ANSI/DASMA 108 TO A DESIGN LOAD OF +/- 55.OPSF -THE LARGE MISSILE IMPACT TEST PER TAS 201 AND ANSI/DASMA 116 WITH THE IMPACT DIRECTION TOWARD THE EXTERIOR FACE OF THE SLATS. -THE CYCLIC WIND PRESSURE TEST PER TAS 203 AND ANSI/DASMA 116. -REFERENCE ELEMENT-ORLANDO, TEST REPORT #ESP010181P, TESTING DATES: 6/18/12 - 6/21/12. 6. BOTTOM BAR ASSEMBLY FASTENED 5 3/4" FROM EACH END AND 12' O.C. FROM CENTER USING 5/16" x 1"CARRIAGE BOLTS. cel7lf-l/Z ". &0K -., OP �p.•��GENq& * _ Pilo. 7768 : - STATE pF • r °�+ Wt % OR10''•• At. SEAL .A = t-/-.032 .XX = +/- A16 xl0c " +/- .005 -C -/- 5 DRAWN BY. BCLLG ISSUE: 08,23-12 M 4255 McEver industrial Dr. Aci mrth. GA 30101 PH:(770) 924-2600/Fax:(770) 974.1455 www.astadow corn 400 SM S RAT SLAT (QED WKILOAD AM WACT RATED ROLLM STEEL" SERVICE DOOR tee-e'w�ioH MODELS ELEMENT-ORLANDO 422FIM 22 GAUGE 124 PREMIER ROAD 420FIM•20 GAUGE OR O FL MR 418FItt 18 GAUG£ TESTREPORT 8ESP01018115 TEST DATES: 6/18112 - 6/22112