# C %roia
!DApproved
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
ardy
CHouston,706055
:)
Ext 28612om
Authorized Signature
Jason Allen
jallen@ncilp.com
Technical Representative
Jason Allen
Address/Phone/Email
14031 West Hardy
Houston, TX 77060
(281) 445-8555 Ext 28612
jallen@ncilp.com
Quality Assurance Representative
Jack Bell
Address/Phone/Email
14031 West Hardy
Houston, TX 77060
(281) 445-8555
jbell@mbci.com
Category
Panel Walls
Subcategory
Siding
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional
Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Bala Sockalingam
PE-62240
UL LLC
12/31/2023
Yoosef Lavi, P.E.
Validation Checklist - Hardcopy Received
FL11917 RCOI_CertificateInddbVY
Standard VILE
ASTM E1592
Year
2012
https://fioridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsxYleb4opODXkToEzN2GsU2s%2bKhg6r%2bLRBObllc77sBg%3d%3d Page 1 of '3
Florida Building Code Online 3/28/21, 10:58 QM
Product Approval Method Method 1 Option D
Date Submitted 11/08/2018
Date Validated 12/19/2020
Date Pending FBC Approval 01/02/2021
Date Approved 02/09/2021
Summary of Products
FL #
Model, Number or Name
Description
11917.1
Artisan L-12
Min 24 ga., max 12" wide, 1" deep concealed fastened wall panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11917 94_II_EvaluationReportC2423 I,pd
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +60.0/-85.0
Evaluation Reports
Other: Allowable load of +60/-50 psf at support spacing of 48" o.c. and
FL11917 R4 AE EvaluationReportC2423 I.odf
-85 psf at support spacing of 12" o.c.
Created by Independent Third Party: Yes
111917.2 I AVP Panel I Min 26 ga., 36" wide through fastened wall panel
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11917 R4 II EvaluationReoortC2423 2.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +23.4/-161.3 Evaluation Reports
Other: Allowable load of +23.4/-22.1 psf at support spacing of 96" o.c. FL11917 R4 AE_EvaluationReoortC2423 2.pdf
and -161.3 psf at support spacing of 24" o.c Created by Independent Third Party: Yes
111917.3 I Designer Series Fluted Panel I Min 24 ga., max 16" wide, 1.75" deep concealed fastened wall panel I
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11917 L4 JI EvaluationReportC2423 3.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +30.0/-85.0 Evaluation Reports
Other: Allowable load of +30/-17.5 psf at support spacing of 96" o.c. FL11917 R4_AE Eva luationRepo rtC2423 3.-p f
and -85 psf at support spacing of 24" o.c. Created by Independent Third Party: Yes
111917.4 I FW-120 Panel I Min 24 ga., max 12" wide, 1.5" deep concealed fastened wall panels -I
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11917 R _JI_F_valuationReportC2423 4.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +80.0/-151.0 Evaluation Reports
Other: Allowable load of +80/-43.75 psf at support spacing of 48" o.c. FL11917 R4_AE Eva luationReoortC2423 4.pdf
and-151..p.S.f at support spacing of 12" o.c. Created by Independent Third Party: Yes
11917.5 1 PBR Panel
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +150.0/-142.5
Other: Allowable load of +150/-142.5 psf at support spacing of 48" o.c.
for 22 ga. panels.
Min 29 ga., 36" wide through fastened wall panel
Installation Instructions
FL11917 R4_II EvaluationReoortC2423 5.odf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
by Independent Third Party: Yes
11917.E �" 1 adowRib Pan Min 24 ga., max 16" wide, 3" deep concealed fastened wall panels
Limits of Use Installation Instructions I
Approved for use in HVHZ: No FL11917 R4 II_ EvaluationReportC2423 " ff
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +45.0/-95.0 Evaluation Reports
Other: Allowable load of +45/-17.5 psf at support spacing of 96" o.c. FL11917 R4 AE_Eva IuationReportC2423_6 pdf
and -95 psf at support spacing of 24" o.c. Created by Independent Third Party: Yes
uacie Next
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
https://floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsxYleb4opODXIcTOEzN2GsU2s%2bKhg6r%2bLRBObllc77sBg%3d%3d Page 2 of 3
a
Solemn
PRODUCTV REPORT
PIER IAA
FLORIDA HMO I TION". (2020)
.T .0 V
FLORIDAPR.A�CiDTUCTI
FL 11917.5-R4
PM- EL WALLS.
smm
Prepared For,.,
art of the Cornerstone Building Brands fawllyy.
14031 West Hardy
HoustonTX 77064.
Telephone: (844) 327-1748
Fax-..'(28-1) 4454110
Prepared -BY:
Bale SockWingamq.Ph.D.s,RX.
Florida. rro�esslonal Engineer #62240
12-16 N Lonsing AM!, Suite C
Tulsa, OK 7,4106
Telephone: (01*4925992.
.FAX,::(.866) 36,6-1543
This report- consists of
Evaluation Report-(3 Pages including cover)
Installation Details (I Page)
Report No. C2423.5
batev. 12.17.2020
FL 11917.5-R4
C2423-5
12.17.2020
Page 2 of 3
Manufacturer: MBCI, part of the Cornerstone Building Brands family.
Manufacturing Houston: 14031 West Hardy, Houston, TX 77064
Locations: Atlanta: 2280 Monier Ave., Lithia Springs, GA 30122
Adel: 1600 Rogers Road, Adel, GA 31620
Product Name: PBR Panel
Panel Description: 36" wide coverage with (4) 1-1/4" high ribs
Materials: Min. 29 ga., 80 ksi steel or min. 24 ga., 50 ksi steel. Galvanized coated
steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted
steel (ASTM A755) as per FBC 2020 Section 1405.2.
Support Description: Min. 16 ga., 50 ksi steel section. (Must be designed by others)
Design Pressure: 29 ga.: +60 and -55 psf at support spacing of 48" o.c.
(Factor of Safety = 2) 26 a.: +90 and -80 psf at support spacing of 48" o.c.
4 ga.: +10- 0 ��� gaapporispaciri 0 48" o.c. with two
fasteners at each rib.
Panel Attachment: 1/4"-14 x 1-1/4" 1, ng corrosion resistant self -drilling screws with washer.
At panel ends _ `='=�' oS cross panel width
At intermediate 12" o.c. across panel width for 29, 26 and 24 ga. panels
o.c. across panel width for 22 ga. panels
Sidelap Attachment: %4"-14 x 7/8" long corrosion resistant self -drilling screws with washer at
20" O.C.
Test Standards: Wall assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure Difference'.
Test Equivalency: The test procedures in ASTM E1592-01 comply with test procedures
prescribed in ASTM E1592-05(2012).
Code Compliance: The product described herein has demonstrated compliance with FBC
2020 Section 1404.5.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. The design pressure for reduced support spacing may be
computed using rational analysis prepared by a Florida Professional
r FL 11917.5-R4
C2423-5
12.17.2020
Page 3 of 3
Engineer. This evaluation report is not applicable in High Velocity
Hurricane Zone.
Supporting Documents: ASTM E1592 Test Reports
Force Engineering & Testing, Inc.
07-0200T-14 A, B, C. Reporting Date 9/29/2014
• r '
SAW_
2 1/2'
?k __• t/4-11ii k%W/1E r UFE$Qf
1 IDNC- V
PBR PANEL FASTENER PATTERN
'/4`'}X EFAM " # (AT INTERMEDIATE SUPPORTS
.1N/�YIISHER [FA5IFNFIt f}]O ?0" O.C. � )if
.
sum
v J5.
r s 7.. 5, L
r z i/z
avrucnno— F.
q - k
Man
PBR PANEL SIDE LAP DETAIL
- -It
t
PBR PANEL FASTENER PATTERN 9 —
(AT- PANEL ENDS)