Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Products Review; Energy Plate Liner
pratecto !NL M-110% The Only Self -Adhesive Air Protecto Energy Plate LmerO is designed specifically for conforming and sealing off the air gaps and Moisture Barrier between the floor deck and the exterior wall plates. The unique peel and stick adhesive bottom etween the Floor Deck of Protecto Energy Plate Liner allows for easy and precise placement. The 1/41, closed cell foam and Wall Plate forms a gasket seal beneath the exterior wall plate virtually eliminating any air drafts resulting in a tremendous amount of heating and air conditioning energy savings. —Tho only peel and stick 1/41, closed cell foam plate liner that totally stops air and moisture infiltration between the wood floor and wall plate Can be used in residential; commercial and, multifamily construction — Self -adhering for easy and precise placement —Exceeds all local, state and national building codes i (elver len /2' grid 1/21' Widths Conforms and seals off irregularities .between substrates (i.e. warped wood to wood, metal frame to concrete, etc.) Stops dangerous carbon monoxide from enterrn9 the home ftom garage sill areas Exiremely resilient, will `not rot of deteriorate with age — Adheres to wood, concrete, metal, block, vinyl and foam:s:urfaces AU I g BLE SERE 3 1/211 x 25 r Roll 5 1/211 x 251 RoH Notect0 �.� APPLICATION: Areas to be sealed must be clean and dry. Align Protecto Energy Plate Liner with the exterior perimeter A your floor deck. As you begin rolling out the Protecto Energy Plate Liner, remove the release paper nd press the adhesive bottom into place. Pressure is essential for gaining maximum adhesion to the bstrate. Continue with yourframe construction. ALLATION BELOW 400: ;p Protecto Energy Plate Liner in a warm heated space above 60OF before use. le the top of the foundation with # 100 Primer" and allow primer to tack up. Do not cover wet primer. o veel and stick the Protecto Energy Plate Liner in place. "Note: Protecto Wrap Protecto-Tak 16.25 oz. spray adhesive may be used in place of 0100 Primer. 0 0 r: i ::._E Ifl1HE Protearo Wrap Comparry. �gp ►® • L 1955S..Cherokee Street Denver, C0 8028 (800) 759 9127 tvwvr FrotectoNlrap cam o PEPL-200 (04-17) IT 77 ©ro o0 FZi Premium Building Products That Protect 1. Product Name Protecto Energy Plate Liner"' Primers & Accessories a Protecto-Tak Spray Primer a No, 100-Primer 2. Manufacturer Protecto Wrap Co. 1955 South Cherokee St, Denver, CO 80223 (800) 759-9727 (303) 777-3001 Fax: (303) 777-9273 E-mail: info@protectowrap.com www,protectowrap.com 3. Product Description BASIC USE otecto Energy Plate Uner m is designed specif- ically to conform to and seal off the air gaps between the floor deck and exterior wall plates. The unique peel -and -stick adhesive bot- tom of Protecto Energy Plate Liner allows for easy and precise placement, The 1/4" (6.4 mm) closed cell foam forms a gasket seal beneath the exterior wall plate that virtually eliminates any air drafts, resulting in tremendous energy savings. Protecto Energy Plate Liner is suitable for application in residential, commercial and multifamily construction. BENEFITS • This 1/4" (6.4 mm) closed cell foam plate liner totally stops air and moisture infiltration between the wood floor and wall plate to significantly reduce energy costs a Extremely resilient - Will not rot or deterio- rate with age o Self -adhering for easy and precise placement a Exceeds all local, state and national build- ing codes a Adheres to concrete, block, wood, metal, vinyl, brick and foam surfaces a Has among the most aggressive adhesives of any sealing tapes a Prevents carbon monoxide from entering living or work spaces through garage areas l'r V �o�co o it lJ lJ�I MARROW 072500_10006770_O1 SD_20966 1/4/06 new 2007 COMPOSITION & MATERIALS Protecto Energy Plate Liner is a 1/4" (6.4 mm) thick, aggressive rubberized adhesive membrane that forms an air/vapor moisture barrier system. The product is a black, opaque, sticky solid with a white or colored foam layer with no odor. SIZE Protecto Energy Plate Liner is available in 31/2" and 51/2" (89 and 140 mm) widths. PACKAGING o 31/2"x25(89mmx7.6m) 0 51/2"x25(140mmx76m) LIMITATIONS Do not use solvent based caulks in conjunc- tion with Protecto Energy Plate Liner, from exposure to harmful environmental conditions and at temperature and humidity 4. Technical Data conditions recommended by the manufacturer. APPLICABLE STANDARDS Verify that site conditions are acceptable ASTM International - ASTM E283 Standard Test for installation. Do not proceed with installation Method for Determining Rate of Air Leakage until unacceptable conditions are corrected. Through Exterior Windows, Curtain Walls, and Surfaces should be clean, dry, free of dirt Doors Under Specified Pressure Differences and other foreign matter, Knock o _end Across the Specimen any roor�ja ged ed es Solvent based caulks should not be used in conjunction APPROVALS with Protecto Energy Plate Liner. This product Protecto Energy Plate Liner exceeds all local, eliminates the need for caulk. T state and national building codes. Consult or es `resu igpgroteciohergy ale manufacturer for current information on Liner at a temperature above 45 degrees F approvals by code bodies and other industry (7 degrees Q. For applications from 20 - 45 entities. degrees F (7 - 7 degrees C), the material must PHYSICAL PROPERTIES be stored in a warm area above 60 degrees o Flash point - > 320 degrees F (160 degrees C) F (16 degrees C) prior to use. a Bulk density-15.723 lb/gal APPLICATION o Specific gravity - 1.883 Apply Protecto-Tak Spray Primer or No. 100 a Melting point (softening point) - 220 degrees F Primer to clean surface and allow to dry prto (104 degrees C) to installing Protecto Energy Plate Liner, Do not o VOC content - 0% cover wet primer. ^" ENVIRONMENTAL CONSIDERATIONS . Ilgn- ro c o ergs ' a e Liner with the Protecto Energy Plate Liner was tested and exterior perimeter of the floor deck. As the analyzed at the Oak Ridge National Protecto Energy Plate Liner is unrolled, remove Laboratories and was found to provide signif- the release paper and press the adhesive icant energy savings, bottom into place. Apply adequate pressure to ensure maximum adhesion to the sub- s. Installation strate. Continue with frame construction, ®7 20 @O Protecto Wrap Co. Protecto Energy Plate Uner" STORAGE & HANDLING PRECAUTIONS Store in a cool, well -ventilated area away o Care should be taken not to leave the from excessive heat and sources of ignition. membrane exposed to direct sunlight for PREPARATORY WORK ny caulking that contains solvents must Deliver materials in manufacturer's original, ( not be used on or around the Protecto unopened, undamaged containers with identi Energy Plate Liner membrannee��_ �� ` fication labels intact. Store materials protected a Probe o �'go�ecto Energy Plate Liner �1rv::tt V 4 SPEGDATe and Po AJ USPEC@ are registered trademarks of Read Elsevier Inc. The ten part SPEC -DATA format conforms to the edtorial style 10 Reed I FIRST SrJL'RCE `vo- of The Construction Specifications Institute and is used with their permission. The manufacturer is response for technical accuracy. a2007 Reed Construction Dotos. All Rights Reserved. Construction Data SPECO is not flammable but will burn under fire conditions. Inhalation of vapors from heat- ed product may cause irritation of the nose, throat and respiratory system. Refer to MSDS for additional information and warnings 6. Availability & Cost AVAILABUY Protecto Energy Plate Liner is manufactured in Denver, CO, and is available worldwide through a network of Protecto Wrap distributors, For detailed product information or to find a local representative or distributor, contact the Protecto Wrap Co, COST Protecto Energy Plate Liner is competitively priced, Contact a local representative or the corporate office for information. 7. Warranty Protecto Wrap Co, expressly warrants, subject to the Exclusion Of Warranties provision, that its products shall be fit for the ordinary purposes for •rhich such products are intended for the life- ,ne of the structure. Contact the manufacturer for complete warranty details, S. Maintenance None required, If installed in accordance with manufacturer's recommendations. 9. Technical Services Complete technical assistance and informa- tion are available from Protecto Wrap field representatives and distributors or by con- tacting the manufacturer. 10. Filing Systems Additional product information is available from the manufacturer. AG3G° E O 00 1=7 20 00 Protecto Wrap Co. Protecto Energy Plate Liner" can reduce air infiltration as recommended by the ENERGY STARS Home Sealing Process, •w ,� L...'� 14�19 Reed I FIRST SOURCE SPECGDATAe and MANU-SPECe are ragstered trademarks of Reed Elsevier bc. The ten pad SPEC -DATA format conforms to the editorial style a Construction Data of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. 02007 Reed Construction Data . All Rights Reserved