KSM JOB # :203292-1pd/BS/jam
PERMIT #:
CONTRACTOR:Taylor Made Pools NUC #528
Nuc Model:MC-1DR-P
255 Bridlewood Way Nuc Serial #:MD049528
Fort Pierce, Florida
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE
PERCENT
COMPACTION
1 West 0'-1'40 111.7 113.4 98.5%
2 1'-2'42 -"95.0% +
3 2'-3'45 -"95.0% +
4 3'-4'45 -"95.0% +
5 South 0'-1'45 110.8 113.4 97.7%
6 1'-2'45 -"95.0% +
7 2'-3'47 -"95.0% +
8 3'-4'45 -"95.0% +
9 East 0'-1'50 109.9 113.4 96.9%
10 1'-2'50 -"95.0% +
11 2'-3'49 -"95.0% +
12 3'-4'49 -"95.0% +
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
7/27/2021
Pool Backfill Compaction
for Plumbed Backfill
JOB LOCATION:
Bryan E. Dahlke, P.E. V.P. of Engineering
Degree of Compaction Meets
DATE TESTED:
of Clay and Shell Fragments
In Place Moisture:
Respectfully Submitted:
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
11.5%
July 26, 2021
ITEM TESTED :
Soil Description:
113.4
Penetrometer reading indicate the
TEST LOCATION
OF SAMPLE
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
12.0%
PE # 81439
Disclaimer:Contractor is responsible to maintain the pool
backfill in the condition that KSM completed the indicated
passed compaction test.KSM is not responsible if the
poolbackfill has been altered from the approved inspected
condition.
Light Brown Sand with Traces
Minimum Requirement
Email to: fracservices@gmail.com
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
108.0
109.0
110.0
111.0
112.0
113.0
114.0
115.0
7 8 9 10 11 12 13 14 15
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y