Loading...
HomeMy WebLinkAboutA A-501 24 GAUGE STANDING SEAM ROOF 22 GAUGE CORRUGATE METAL n> 6"R-19 VINYL FACED INSULATION BAITS 35 EX-H a b6 PANELS MECHANICALLY FASTENED 12 DECK PER STRUCTURAL = `° z'" AT UNDERSIDE OF ROOFING PANELS TO CORRUGATED ROOF DECK& 1 DETAILS & SPECIFICATIONS g m STEEL ROOF PURLINS PER BUILDING LIGHT GAUGE METAL FRAMING A 24 GAUGE STANDING SEAM ROOF PANELS 12 MANUFACTURER SPECIFICATIONS 24 GAUGE STANDING SEAM ROOF PANELS - Q PER APPROVED BUILDING MANUFACTURER'S 1 AND EAVE CLOSURE COMPONENTS BY EXISTING NEW IN-FILL CONTINUOUS METAL o 4 a ~ ENGINEERED SHOP DRAWINGS BUILDING MANUFACTURER o-- - - ------C�m- GUTTERS AND RAIN LEADERS ` " _ � z .� d STRUCT RE WALL CONTINUOUS TIE-BEAM AT CIO 6"R-19 VINYL FACED INSULATION BATTS HEAD OF MASONRY WALL PER = STRUCTURAL SPECIFICATIONS 1 %"x 12"LIGHT GAUGE STEEL ROOF \ o m c _ JOISTS @ 16 O.C. PER STRUCTURAL \ ` L o RIGID FRAME STRUCTURAL COLUMNS BY r' }e DETAILS & SPECIFICATIONS 2 W a METAL BUILDING MANUFACTURER45 o Y CONTINUOUS METAL $ L U GUTTERS AND RAIN LEADERS EXISTING INSULATION BATTS ATUNDERSIDE SEALANT I: - CONTINUOUS STEEL CLOSURE RIGID STRUCTURAL FRAME STEEL ROOF PURLINS PER 12 MANUFACTURER'S SPECIFICATIONS OF ROOFING PANELS TO REMAIN ° .> "'1" STRIP AT BASE OF WALL PANELS S r N •rrs p, PER APPROVED BUILDING BUILDING MANUFACTURER o 1 O.J.�° 2 HOUR RATED CEILING PERULIMF ATTACHMENT OF TRANSLUCENT ASSEMBLY"P 561"ON SHEET A 5.02 SMOOTH PAINTED STUCCO FINISH OVER REINFORCED CMU WALLS 0 I z WALL PANELS PER BUILDING ENGINEERED SHOP DRAWINGS 3"R-10 VINYL FACED INSULATION EXISTING 24 GAUGE STANDING O MANUFACTURER SPECIFICATIONS BATTS @ WALL PANEL SYSTEM SEAM ROOF PANELS TO REMAIN AND CAST IN PLACE TIE-BEAMS RAKED BEYOND TIE BEAM PER SCHEDULED IMPACT RATED CONTINUOUS FLUID APPLIED STRUCTURAL ENGINEERING DRAWINGS U TRANSLUCENT WALL PANELS FLUSH PANEL DOOR AND MEMBRANE FLASHING 12 AROUND TO MATCH EXISTING 26 GAUGE EXPOSED FASTENER METAL WALL PANEL SYSTEMS PERIMETER OF MASONRY OPENING �/ 0� O V� HOLLOW METAL FRAME I 0) o Q . . . . L1. c., 44 U. - - - - - CRANE COMPONENTS & 0 ¢ * w kQ, W - - - EQUIPMENT PER CRANE EXISTING METAL GUTTERS AND WALLS PAINTED ON z r RAIN LEADERS TO REMAIN INTERIOR FACES TYPICAL O i- Q C-5 MANUFACTURER'S APPROVED REINFORCED CMU WALLS PER ENGINEERED SHOP DRAWINGS U FLAG\ �S � STRUCTURAL DRAWINGS AND ';_ • ATTACHMENT OF NEW WALL PANELS SPECIFICATIONS STEEL WIND GERTS PER BUILDING PER BUILDING MANUFACTURER O I. .Ii. MANUFACTURER SPECIFICATIONS SPECIFICATIONS LL m LAP TRANSLUCENT WALL PANELS I I OVER WALL PANELS PER BUILDING - -_-_- MANUFACTURER SPECIFICATIONS EXISTING RIGID STRUCTURAL NEW 3"R-10 VINYL FACED INSULATION BATTS BEHIND NEW WALL PANEL •_' Lj FRAMES / COLUMNS TO REMAIN SYSTEM SMOOTH PAINTED STUCCO FINISH PAINTED OVER REINFORCED CMU WALLS CMU WALLS BEYOND J Q CRANE RUNWAY AND TRANSLUCENT WALL PANELS HAUNCHES SUPPORTED BY TO MATCH EXISTING _ METAL BUILDING STRUCTURE m NEW 6"THICK CONCRETE SLAB AND REINFORCING LAP TRANSLUCENT WALL PANELS PER STRUCTURAL SCHEDULED GASKETED Cf) ^ OVER WALL PANELS PER BUILDING ENGINEERING DRAWINGS THRESHOLD AT STEEL DOORS F-- MANUFACTURER SPECIFICATIONS 2 HOUR RATED CMU WALLS PER UL Q ASSEMBLY"U 906" ON SHEET A-5.02 � O 3"R-10 VINYL FACED CONTINUOUS STEEL CLOSURE NEW STEEL WIND GERTS OVER EXISTING FINISH FLOOR INSULATION BATTS @ STRIP AT BASE OF WALL PANELS STEEL RIGID FRAME PER BUILDING �-•-�-`.-± " " �--_-` .- � - t . ` � - ; L:"^: `"`=� = =�:�". �" @ EL. 0'-0" A.F.F. � � � � WALL PANEL SYSTEM MANUFACTURER SPECIFICATIONS Lq J 24 GAUGE STANDING SEAM ROOF PANELS CONTINUOUS WEEP SCREEP NEW 6"THICK CONCRETE SLAB AND W m m AT BASE OF STUCCO FINISH CV 5 I` REINFORCING PERSTROCTORAL CD [� Z PAINT EXPOSED PORTIONS NGINEERING DRAWINGS N ,� ILL NEW RIGID STRUCTURAL FRAME .;o. s _ ``�. ': / \ OF FOUNDATION 0 m N COMPONENTS PERAPPROVED _ \\ \\ \\ �y-:_L _ \ \ P s D - FINISH FLOOR 26 GAUGE EXPOSED FASTENER METAL BUILDING MANUFACTURER'S - \ \ ```'4 N�ETE FOUNDATIONS @ EL. 0'-0"A.F.F. N WALL PANEL SYSTEMS PER BUILDING / Y ENGINEERED SHOP DRAWINGS 1'. Y"' ° y " —,� T T — N . ` D b .L ! `�L<. y^ti ..y UCTU AL ` Q N ERING DRAWINGS CD MANUFACTURER SPECIFICATIONS ",MR. y` L. -_v -S L-- _ .. - \ �I�"_ •4..-r -s. '°�:.4:f °-.g-D� \/ ` M W C/� ` _ m N � 3 R-10 VINYL FACED INSULATION L_ _ v` _ \ _a ; -•:;. _ _ _ CONCRETE FOUNDATIONS BAITS PER STRUCTURAL Digitally signed by ENGINEERING DRAWINGS Brent Wood ate . ._�• +�=.`- �.— '- /\/\ // // •D_. _�— // DN:cn=Brent Wood, Brent =Brent A.Wood METHOD OF DOOR/TRACK Architecture,LLC,ou, ATTACHEMENT PER CURRENT % \x / /, // \ �P E \/\/ STEEL WIND GERTS PER BUILDING PRODUCT APPROVAL REQUIREMENTS \\ \\ T I \ \\ / % W OOd larch:omnc=USWoo MANUFACTURER SPECIFICATIONS \ \ \ \ \ \ \ \ \ \ \ // / Date:2021.05.07 INCLUDE AUXILLARY HAND CHAIN �� �� A\ � A �� �� A� �� /�/ /�/ /�/ /�/ /�/ /�/ /j 15:07:04-04'00' MOTORIZED IMPACT RATED ROLL-UP CONTINUOUS STEEL CLOSURE TYPICAL SECTION @ NEW TYPICAL SECTION DOOR ASSEMBLY -SEE PLANS &DOOR I I NEW STEEL WIND GERTS OVER EXISTING SCHEDULE FOR MANUFACTURER& o STRIPATALLDOOROPENINGS ENDWALL EXIT DOOR 4 ELECTRIC ROOM SIDEWAL 5 STEEL RIGID FRAME PER BUILDING PRODUCT APPROVAL DATA i MANUFACTURER SPECIFICATIONS CL SCALE: 3/4" = 1'-01, A-5.Q1 SCALE: 3/4" = V-0" A-5.Q1 METHOD OF DOOR/TRACK N METHOD OF DOOR/TRACK ATTACHEMENT PER CURRENT ATTACHEMENT PER CURRENT PRODUCT APPROVAL REQUIREMENTS IK PRODUCT APPROVAL REQUIREMENTS 24 GAUGE STANDING SEAM ROOF O INCLUDE AUXILLARY HAND CHAIN 24 GAUGE STANDING SEAM ROOF PANELS PANELS MECHANICALLY FASTENED AND EAVE CLOSURE COMPONENTS TO CORRUGATED ROOF DECK& 75 LIGHT GAUGE METAL FRAMING U_ u- MOTORIZED IMPACT RATED ROLL-UP •L 22 GAUGE CORRUGATE METAL DECK PER N E DOOR ASSEMBLY -SEE PLANS &DOOR CONTINUOUS STEEL CLOSURE 2 STRIP ATALL DOOR OPENINGS STRUCTURAL DETAILS & SPECIFICATIONS > O o_ SCHEDULE FOR MANUFACTURER& m -- ~ 22 GA INTERLOCKING SLATPRODUCT APPROVAL DATA 2:2 co N IL COMMERCIAL ROLL-UP DOOR WITH CONTINUOUS STEEL CLOSURE STANDARD FACTORY FINISH STRIP AT BASE OF WALL PANELS 1 %'x 12"LIGHT GAUGE STEEL ROOF CONTINUOUS STEEL CLOSURE BY BUILDING MANUFACTURER METHOD OF DOOR/TRACK BOX JOISTS PER STRUCTURAL T) STRIP AT BASE OF WALL PANELS DETAILS & SPECIFICATIONS BY BUILDING MANUFACTURER ATTACHEMENT PER CURRENT PRODUCT APPROVAL REQUIREMENTS 26 GAUGE EXPOSED FASTENER - _ METAL WALL PANEL SYSTEMS - .� - � � TOP OF C.I.P.TIE-BEAM I' I' S rr O _ - - - "_" t- 1 / x 12"LIGHT GAUGE STEEL ROOF @ EL. 8'-8" A.F.F. { t- JOISTS 16" O.C. PER STRUCTURAL CONTINUOUS STEEL CLOSURE @ ��- •I• DETAILS & SPECIFICATIONS STRIP AT BASE OF WALL PANELS •. " -. � 2 HOUR RATED CEILING PER UL x {d "F ASSEMBLY"P 5 61"ON SHEET A-5.02 w 22 GA INTERLOCKING SLAT COMMERCIAL ROLL-UP DOOR WITH — CONTINUOUS BOND BEAM AT STANDARD FACTORY FINISH RAKED BEYOND TIE BEAM PER Q) HEAD OF MASONRY WALL STRUCTURAL ENGINEERING DRAWINGS W CONTINUOUS TIE-BEAM ATCz HEAD OF MASONRY WALL PER STRUCTURAL SPECIFICATIONS SMOOTH PAINTED STUCCO FINISH OVER REINFORCED CMU WALLS CMU WALLS PAINTED ON Y INTERIOR FACES TYPICAL 0 - I O SMOOTH PAINTED STUCCO FINISH L OVER REINFORCED CMU WALLS GASKETED ASTRAGAL AT BASE OF [z SMOOTH PAINTED STUCCO FINISH ROLL-UP DOOR ASSEMBLY O REINFORCED CMU WALLS PER OVER REINFORCED CMU WALLS m ui STRUCTURAL DRAWINGS AND > PAI ED PAI NTEDCO REINFORCED CMU WALLS PER I SPECIFICATIONS U m CMU ALLS CMU WALLS STRUCTURAL DRAWINGS ANDILL U BEYOND BEY SPECIFICATIONS Qa ` ND REINFORCED CMU WALLS PER /(/ STRUCTURAL DRAWINGS AND z � SPECIFICATIONS / AI NTED METHOD OF DOOR/TRACK I C U WALLS ° BEYOND ATTACHEMENT PER CURRENT PRODUCT APPROVAL REQUIREMENTS -�J EXISTING RIGID FRAME ANCHOR EXISTING RI ID STRUCTURAL LTS AND NON-SHRINK }� FRAMES/COLUMNS TO REMAIN GROUTING TO REMAIN RIGID FRAME ANCHOR BOLTS PER =, CONTINUOUS WEEP SCREEP AT STRUCTURAL ENGINEERING NEW 6"THICK CONCRETE GASKETED ASTRAGAL AT BASE OF SLAB AND REINFORCING NEW 6"THICK CONCRETE SLAB ROLL-UP DOOR ASSEMBLY NEW 6"THICK CONCRETE SLAB BASE OF STUCCO FINISH �J DRAWINGS AND BUILDING WITH MEDIUM BROOM FINISH AT EXISTING "THICK CONTINUOUS WEEP SCREEP AT WITH MEDIUM BROOM FINISH AT _ MANUFACTURER SPECIFICATIONS PER STRUCTURAL CONCRETE SLAB AND PAINT EXPOSED PORTIONS ; : S EXTERIOR SLABS BASE OF STUCCO FINISH EXTERIOR SLABS ENGINEERING DRAWINGjj OF FOUNDATION n n ALI N REINFORCING TO REMAIN n PAINT EXPOSED PORTIONS ALI N 2 HOUR RATED CMU WALLS PER UL J`4, n I I I I I I PANT EXPOF OSED ASSEMBLY"U 906"ON SHEET A-5.02 _ ON FINISH FLOOR _ FINISH FLOOR FINISH FLOOR _ FINISH FLOOR — _ _ L. - .�� 1 11 ?�" [ " L _ _ r L D -. .: - 1 11 _ - - — 1 a" — — _ _ _ EL. 0 0 A.F.F. V : , - EL. 0 0 A.F.F. t %"�_ EL. 0'-0' A.F.F. GRAD y E AWAY ~I r r — — — — @ `-,;. =. _ D @ ':_ SLOPE �. — — y �. L.. J� _ _ _ ` L� FRO `'�,- t " - ---- -- _.MLC_�IT-�1=T7 . ,._+-:•`�`.- r, �-1 .-'.�-c - - - "d=-. . .->e: : _ `� O. II. -:JI-�.u�j _ — / / / / c- / / / \ CONTINUOUS WEEP SCREEP l -.��` " •�- NEW 6 THICK CONCRETE SLAB AND . -rl _ --11.< - - �-_• - - - AT BASE OF STUCCO FINISH q� / - _ / ll"-'--�I-"- ---°"�D / / / / \ \ \ �`-�°.�..�"`.'--`-::_ '"`��- \ \ REINFORCING PERSTROCTORAL / Jk/�,((n/' (+ :- L 7A D I� k" ,: ,_D U. I .i \ \ \ y PAINT EXPOSED PORTIONS \ �S\ \ J ENGINEERING DRAWINGS \ \ `'IIrr e q \ \ \ \ \ \ \ , OF FOUNDATION / °-`�' --,..� -`�_L�`-T y�Ll�_3_,/``` •O-`-,- e. �L�,--`--"--. - \ \ \ \ \ /\ \/ \ \ \ \ F <II•'°..i� °A f" \ \ \ a \ - FINISH FLOOR TE FOUNDATIONS / / / i " "�""� O^ TIE FOUNDATIONS IV — p. / \ \ \ ,a - ; ' N TE FOUNDATIONS — 1 " - •�-= '-_�: - .« " - _ _ - 'L - _`"- - "- - ,_ _ _ �-�_�----- -•�- EL. 0-0 A.F.F. � L i Rl1CTl1RAL T�4lJCTORAL UCTURAL i - - E: - _..w_V _ / _ '-��� G TE FOUNDATIONS W T _ - w a—_�.o''T., _ —o—`-`—Lea-"� o_`�L�- . - - �_ .- :�_ --°—��-�— :—moo- . . .• 'E G RING DRAWINGS �. . a.. _ RING DRAWINGS _ _ _ I ERING DRAWINGS \ \ r � '` - �� T UCTURAL _ RING DRAWINGS _\ \�,/�/C�I " r L c, `L. L J r L t s z 1 .-c ..\. _ v _ •t`.Y_ ` :L 4. _ i. _„a�' .. :..yam' / `V —•` L �'G ,°-0-'— -� � �'O` is Ak- � :4 :T : ` ..�.� -.�4 - =ate /\/ \/\ \ \ \ \ ` /\/\ / // / X // /� \ \ \\ \ \ \\ \\ // // / •N �_ N-F ILL \ \\ \\ \ T �I \\ \ TWALL -� / / / \ \ \\ \\ \� \\ o Q c o TYPICAL SECTION NEW TYPICAL SECTION NEW TYPICAL SECTION COVERED TYPICAL SECTION @ NEW TYPICAL SECTION L6 L: Q MASONRY / METAL BUILDINGWALL COVERED LOADING AREA EN WALL PATIO / WAREHOUSE NCLOSURE 3 ENDWALL ROLL-UP DOOR 6 ELECTRIC ROOM ENDWAL 7 Q Z SCALE: 3/4" = V-0" A-5.Q1 SCALE: 3/4" = 1'-0" A-5.01 SCALE: 3/4" = V-0" A-5.01 SCALE: 3/4" = V-0" A!I01 SCALE: 3/4" = V-0" A-5.Q1 a cif d d O