BUILDING CODE REVIEW - FBC 2020 - 7th Edition = = N
_ � ti
9 ai
. N4 . 0 �
Via ' "- `> io
' 4 n J
s
SECTION1005 SECTION1008 SECTION1a10 SECTION1016 ' � � F-
10 e
MEANS OF EGRESS SIZING MEANS OF EGRESS ILLUMINATION DOORS, GATES AND TURNSTILES EXIT ACCESS 9 F a
(CONTINUED FROM GN-3) (CONTINUED) y
(CONTINUED) € m
1016.1 GENERAL. y
_ � �
p.i
1005.7.1 DOORS. 1008.3.3 ROOMS AND SPACES. 1010.1.8 DOOR ARRANGEMENT. THE EXIT ACCESS SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF SECTIONS 1003 THROUGH 1015.EXIT ACCESS N f ° s
DOORS,WHEN FULLY OPENED,SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN 7 INCHES(178 MM),DOORS IN THE EVENT OF POWER SUPPLY FAILURE,AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE SPACE BETWEEN TWO DOORS IN A SERIES SHALL BE 48 INCHES(1219 MM)MINIMUM PLUS THE WIDTH OFA DOOR ARRANGEMENT SHALL COMPLY WITH SECTIONS 1016 THROUGH 1021, j L m a � o
N C = ._
IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN ONE-HALF. ALL OF THE FOLLOWING AREAS: SWINGING INTO THE SPACE.DOORS IN A SERIES SHALL SWING EITHER IN THE SAME DIRECTION OR AWAY FROM THE L ,, : w Q
SPACE BETWEEN THE DOORS. 1016.2 EGRESS THROUGH INTERVENING SPACES. ,6 z d
� �
EXCEPTIONS: 1.ELECTRICAL EQUIPMENT ROOMS. EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH THIS SECTION. L ° L ai v
1.SURFACE-MOUNTED LATCH RELEASE HARDWARE SHALL BE EXEMPT FROM INCLUSION IN THE 7-INCH MAXIMUM(178 2,FIRE COMMAND CENTERS. EXCEPTIONS: � .Q � g V) O
MM)ENCROACHMENT WHERE BOTH OF THE FOLLOWING CONDITIONS EXIST: 3,FIRE PUMP ROOMS, 17HE MINIMUM DISTANCE BETWEEN HORIZONTAL SLIDING POWER-OPERATED DOORS IN A SERIES SHALL BE 48 INCHES 1,EXIT ACCESS THROUGH AN ENCLOSED ELEVATOR LOBBY IS PERMITTED.ACCESS TO NOT LESS THAN ONE OF THE
u '4 i4 E 3
a)
4.GENERATOR ROOMS. (1219 MM). REQUIRED EXITS SHALL BE PROVIDED WITHOUT TRAVEL THROUGH THE ENCLOSED ELEVATOR LOBBIES REQUIRED BY 0 - •v co r 4 ur co r_
1.1.THE HARDWARE IS MOUNTED TO THE SIDE OFTHE DOOR FACING AWAY FROM THE ADJACENT WALL WHERE THE 5.PUBLIC RESTROOMS WITH AN AREA GREATER THAN 300 SQUARE FEET(27.87 M2). 2.STORM AND SCREEN DOORS SERVING INDIVIDUAL DWELLING UNITS IN GROUPS R-2 AND R-3 NEED NOT BE SPACED 48 SECTION 3006, NOT TO APPLY IF THE LOBBY IS ONLY PROVIDED TO MEET THE REQUIREMENTS OF SECTION 3007.6, 1 O
DOOR IS IN THE OPEN POSITION. INCHES(1219 MM)FROM THE OTHER DOOR. EXCEPTION 1.WHERE THE PATH OF EXIT ACCESS TRAVEL PASSES THROUGH AN ENCLOSED ELEVATOR LOBBY,THE z
1008.3.4 DURATION. 3.DOORS WITHIN INDIVIDUAL DWELLING UNITS IN GROUPS R-2 AND R-3, LEVEL OF PROTECTION REQUIRED FOR THE ENCLOSED ELEVATOR LOBBY IS NOT REQUIRED TO BE EXTENDED TO THE O
1.2.THE HARDWARE IS MOUNTED NOT LESS THAN 34 INCHES(865 MM)NOR MORE THAN 48 INCHES(1219 MM)ABOVE THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND EXIT UNLESS DIRECT ACCESS TO AN EXIT IS REQUIRED BY OTHER SECTIONS OFTHIS CODE.
THE FINISHED FLOOR. SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR.THE INSTALLATION OFTHE 1010.1.9 DOOR OPERATIONS.
EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH SECTION 2702. EXCEPT AS SPECIFICALLY PERMITTED BY THIS SECTION,EGRESS DOORS SHALL BE READILY OPENABLE FROM THE 2.EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH ADJOINING OR INTERVENING ROOMS ORAREAS, U J.0
2.THE RESTRICTIONS ON DOOR SWING SHALL NOT APPLY TO DOORS WITHIN INDIVIDUAL DWELLING UNITS AND EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT, EXCEPT WHERE SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED ARE ACCESSORY TO ONE ORTHE OTHER, � `QP 0 �
SLEEPING UN ITS OF GROUP R-2 OCCUPANCIES AND DWELLING UNITS OF GROUP R-3 OCCUPANCIES. 1008.3.5 ILLUMINATION LEVEL UNDER EMERGENCY POWER. ARE NOT A GROUP H OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS TRAVELTO AN EXIT. � 0 QQ c4 - 0
EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN AN 1010.1.9.1 HARDWARE. I 0 o Q
1005.7.2 OTHER PROJECTIONS. AVERAGE OF 1 FOOTCANDLE (11 LUX)AND A MINIMUM AT ANY POINT OF 0.1 FOOTCANDLE (1 LUX)MEASURED ALONG DOOR HANDLES, PULLS,LATCHES,LOCKS AND OTHER OPERATING DEVICES ON DOORS REQU IRED TO BE ACCESSIBLE EXCEPTION: MEANS OF EGRESS ARE NOT PROHIBITED THROUGH ADJOINING OR INTERVENING ROOMS OR SPACES u. Q * t'�. p
HANDRAIL PROJECTIONS SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF SECTION 1014,8,OTHER THE PATH OF EGRESS AT FLOOR LEVEL, ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOTCANDLE BY CHAPTER 11 SHALL NOT REQUIRE TIGHT GRASPING,TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. IN A GROUP H,S OR F OCCUPANCY WHERE THE ADJOINING OR INTERVENING ROOMS OR SPACES ARE THE SAME 0 r I w A W
NONSTRUCTURAL PROJECTIONS SUCH AS TRIM AND SIMILAR DECORATIVE FEATURES SHALL BE PERMITTED TO (6 LUX)AVERAGE AND A MINIMUM AT ANY POINT OF a.a6 FOOTCANDLE (0.6 LUX)AT THE END OF THE EMERGENCY OR A LESSER HAZARD OCCUPANCY GROUP. z 13� 2 Q a �It
PROJECT INTO THE REQUIRED WIDTH NOT MORE THAN 11/2 INCHES(38 MM)ON EACH SIDE. LIGHTING TIME DURATION.A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE 1010.1.9.2 HARDWARE HEIGHT. 0 `r6� far& ,
EXCEEDED. IN GROUP 1-2 OCCUPANCIES,FAILURE OF ANY SINGLE LIGHTING UNIT SHALL NOT REDUCE THE DOOR HANDLES, PULLS,LATCHES,LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34 INCHES(864 MM) 3.AN EXIT ACCESS SHALL NOT PASS THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS. 0 S a�G�
EXCEPTION:PROJECTIONS ARE PERMITTED IN CORRIDORS WITHIN GROUP 1-2 CONDITION 1 IN ACCORDANCE WITH ILLUMINATION LEVEL TO LESS THAN 0.2 FOOT-CANDLE (2,2 LUX). MINIMUM AND 48 INCHES(1219 MM)MAXIMUM ABOVE THE FINISHED FLOOR.LOCKS USED ONLY FOR SECURITY .
SECTION 407.4.3. DANCE WITH SECTION 1a07,1.3. PURPOSES AND NOT USED FOR NORMAL OPERATION ARE PERMITTED AT ANY HEIGHT. 4,MEANS OF EGRESS FROM DWELLING UNITS OR SLEEPING AREAS SHALL NOT LEAD THROUGH OTHER SLEEPING
AREAS,TOILET ROOMS OR BATHROOMS. Q m
a)
1005.7.3 PROTRUDING OBJECTS. EXCEPTION:ACCESS DOORS OR GATES IN BARRIER WALLS AND FENCES PROTECTING POOLS,SPAS AND HOT TUBS LL w
PROTRUDING OBJECTS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTION 1003,3, SECTION 1a10 DOORS, GATES AND TURNSTILES SHALL BE PERMITTED TO HAVE OPERABLE PARTS OF THE RELEASE OF LATCH ON SELF-LATCHING DEVICES AT 54 5.EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR
INCHES(1370 MM)MAXIMUM ABOVE THE FINISHED FLOOR OR GROUND,PROVIDED THE SELF-LATCHING DEVICES ARE PURPOSES, Digitallysigned by Brent
1006.1 GENERAL. 1 a1a.1 DOORS. NOT ALSO SELF-LOCKING DEVICES OPERATED BY MEANS OF A KEY,ELECTRONIC OPENER OR INTEGRAL COMBINATION EXCEPTIONS: Lu Brent
A.Wood
THE NUMBER OF EXITS OR EXIT ACCESS DOORWAYS REQUIRED WITHIN THE MEANS OF EGRESS SYSTEM SHALL LOCK DN:cn=Brent A.Wood,
COMPLY WITH THE PROVISIONS OF SECTION 1006.2 FOR SPACES, INCLUDING MEZZANINES,AND SECTION 1006.3 FOR MEANS OF EGRESS DOORS SHALL MEET THE REQUIREMENTS OF TH IS SECTION,DOORS SERVING A MEANS OF EGRESS 1.MEANS OF EGRESS ARE NOT PROHIBITED THROUGH A KITCHEN AREA SERVING ADJOINING ROOMS U3 o=Brent A.Wood
STORIES. SYSTEM SHALL MEET THE REQUIREMENTS OF THIS SECTION AND SECTION 1022.2. DOORS PROVIDED FOR EGRESS 1010.1.9.5 BOLT LOCKS. CONSTITUTING PART OF THE SAME DWELLING UNIT OR SLEEPING UNIT. J Architecture,LLC.,
PURPOSES IN NUMBERS GREATER THAN REQUIRED BY THIS CODE SHALL MEET THE REQUIREMENTS OF THIS SECTION. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED A. ou=Architecture,
FOR ACCESSIBILITY PROVISIONS RELATED TO DOORS, REFER TO THE FLORIDA BUILD ING CODE,ACCESSIBILITY. email=erick@bawoodarc
1006.2 EGRESS FROM SPACES. 2.MEANS OF EGRESS ARE NOT PROHIBITED THROUGH STOCKROOMS IN GROUP M OCCUPANCIES WHERE ALL OF ` A ,OO t h.com,c=US
ROOMS,AREAS OR SPACES, INCLUDING MEZZANINES,WITHIN A STORY OR BASEMENT SHALL BE PROVIDED WITH THE EXCEPTIONS: THE FOLLOWING ARE MET: VV a Date:2021.05.0816:06:44
NUMBER OF EXITS OR ACCESS TO EXITS IN ACCORDANCE WITH THIS SECTION. MEANS OF EGRESS DOORS SHALL BE READILY DISTINGUISHABLE FROM THE ADJACENT CONSTRUCTION AND FINISHES 1.ON DOORS NOT REQUIRED FOR EGRESS IN INDIVIDUAL DWELLING UNITS OR SLEEPING UNITS. 21 THE STOCK IS OF THE SAME HAZARD CLASSIFICATION AS THAT FOUND IN THE MAIN RETAILAREA, ~ -04'00'
SUCH THAT THE DOORS ARE EASILY RECOGNIZABLE AS DOORS. MIRRORS OR SIMILAR REFLECTING MATERIALS SHALL 2.WHERE A PAIR OF DOORS SERVES A STORAGE OR EQUIPMENT ROOM,MANUALLY OPERATED EDGE-OR 2,2,NOT MORE THAN 50 PERCENT OF THE EXIT ACCESS IS THROUGH T HE STOCKROOM,
1006.2.1 EGRESS BASED ON OCCUPANT LOAD AND COMMON PATH OF EGRESS TRAVEL DISTANCE. NOT BE USED ON MEANS OF EGRESS DOORS. MEANS OF EGRESS DOORS SHALL NOT BE CONCEALED BY CURTAINS, SURFACE-MOUNTED BOLTS ARE PERMITTED ON THE INACTIVE LEAF. 2.33HE STOCKROOM IS NOT SUBJECT TO LOCKING FROM THE EGRESS SIDE. l
TWO EXITS OR EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED WHERE THE DESIGN OCCUPANT LOAD DRAPES,DECORATIONS OR SIMILAR MATERIALS. 3.WHERE A PAIR OF DOORS SERVES AN OCCUPANT LOAD OF LESS THAN 50 PERSONS IN A GROUP B,F OR S 2.4.THERE IS A DEMARCATED,MINIMUM 44-INCH-WIDE(11 18 MM)AISLE DEFINED BY FULL-OR PARTIAL-HEIGHT m ~l
OR THE COMMON PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1.THE OCCUPANCY,MANUALLY OPERATED EDGE-OR SURFACE-MOUNTED BOLTS ARE PERMITTED ON THE INACTIVE LEAF. FIXED WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN THE REQUIRED WIDTH AND LEAD DIRECTLY =) i--I
CUMULATIVE OCCUPANT LOAD FROM ADJACENT ROOMS,AREAS OR SPACES SHALL BE DETERMINED IN ACCORDANCE 1010.1.1 SIZE OF DOORS. THE INACTIVE LEAF SHALL NOT CONTAIN DOORKNOBS,PANIC BARS OR SIMILAR OPERATING HARDWARE, FROM THE RETAIL AREA TO THE EXIT WITHOUT OBSTRUCTIONS. U] ^
WITH SECTION 10042, THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOFAND 4.WHERE A PAIR OF DOORS SERVES A GROUP B,F OR S OCCUPANCY, MANUALLY OPERATED EDGE-OR F__ V-) W
SHALL PROVIDE A MIN IMUM CLEAR OPENING WIDTH OF 32 INCHES(813 MM),THE CLEAR OPENING WIDTH OF SURFACE-MOUNTED BOLTS ARE PERMITTED ON THE INACTIVE LEAF PROVIDED SUCH INACTIVE LEAF IS NOT NEEDED EXCEPTIONS: _ O 04
DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP,WITH TO MEET EGRESS CAPACITY REQUIREMENTS AND THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SECTION1017 CC
THE DOOR OPEN 90 DEGREES (1.57 RAD).WHERE THIS SECTION REQUIRES A MINIMUM CLEAR OPENING WIDTH OF 32 SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903,3,1.1.THE INACTIVE LEAF SHALL NOT CONTAIN DOORKNOBS, EXIT ACCESS TRAVEL DISTANCE G
1 THE NUMBER OF EXITS FROM FOYERS,LOBBIES,VESTIBULES OR SIMILAR SPACES NEED NOT BE BASED ON INCHES(813 MM)AND A DOOR OPEN ING INCLUDES TWO DOOR LEAVES WITHOUT A MULLION,ONE LEAF SHALL PROVIDE PANIC BARS OR SIMILAR OPERATING HARDWARE. O co 0) -
CUMULATIVE OCCUPANT LOADS FOR AREAS DISCHARGING THROUGH SUCH SPACES,BUT THE CAPACITY OFTHE EXITS A MINIMUM CLEAR OPENING WIDTH OF 32 INCHES(813 MM), IN GROUP I-2,DOORS SERVING AS MEANS OF EGRESS 5.WHERE A PAIR OF DOORS SERVES PATIENT CARE ROOMS IN GROUP 1-2 OCCUPANCIES, SELF-LATCHING EDGE-OR 1017.1GENERAL. LLI
DOORS WHERE USED FOR THE MOVEMENT OF BEDS SHALL PROVIDE A MINIMUM CLEAR OPENING WIDTH OF411/2 �
FROM SUCH SPACES SHALL BE BASED ON APPLICABLE CUMULATIVE OCCUPANT LOADS. SURFACE-MOUNTED BOLTS ARE PERMITTED ON THE INACTIVE LEAF PROVIDED THAT THE INACTIVE LEAF IS NOT TRAVEL DISTANCE WITHIN THE EXIT ACCESS PORTION OF THE MEANS OF EGRESS SYSTEM SHALL BE IN � r � � �
INCHES(1 D54 MM).THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE 48 INCHES (1219 MM)NOMINAL.THE NEEDED TO MEET EGRESS CAPACITY REQUIREMENTS AND THE INACTIVE LEAF SHALL NOT CONTAIN DOORKNOBS, ACCORDANCE WITH THIS SECTION, I `./ LL
MINIMUM CLEAR HEIGHT OF DOOR OPENINGS SHALL BE NOT LESS THAN 80 INCHES(2032MM). PANIC BARS OR SIMILAR OPERATING HARDWARE, N
2,CARE SUITES IN GROUP I-2 OCCUPANCIES COMPLYING WITH SECTION4a7.4, � � W pp � ni
1017.2LIMITATIONS.
1a06.2.1.1THREE OR MORE EXITS OR EXIT ACCESS DOORWAYS.
1a10.1.1.1 PROJECTIONS INTO CLEAR WIDTH_ 1010.1.9.6 UNLATCHING. EXIT ACCESS TRAVEL DISTANCE SHALL NOT EXCEED THE VALUES GIVEN IN TABLE 1017.2. N U �O x
THREE EXITS OR EXIT ACCESS DOORWAYS SHALL BE PROVIDED FROM ANY SPACE WITH AN OCCUPANT LOAD OF 501 THERE SHALL NOT BE PROJECTIONS INTO THE REQUIRED CLEAR OPEN ING WIDTH LOWER THAN 34 INCHES{864 MM) THE UNLATCH ING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. *---4Z -0 LL
TO 1,000. FOUR EXITS OR EXIT ACCESS DOORWAYS SHALL BE PROVIDED FROM ANY SPACE WITH AN OCCUPANT LOAD ABOVE THE FLOOR OR GROUND.PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES(864 MM)AND 80
INCHES 2032 MM ABOVE THE FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES 102 MM . TABLE 1017.2 O E N
GREATER THAN 1,aaa, ( ) ( ) EXCEPTIONS: EXIT ACCESS TRAVEL DISTANCE a � Z � o �
1.PLACES OF DETENTION OR RESTRAINT. � 2 aa)
EXCEPTION: DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES(1980 MM)MINIMUM ABOVE THE 2.WHERE MANUALLY OPERATED BOLT LOCKS ARE PERMITTED BY SECTION 1010.1.9.5. OCCUPANCY WITHOUT SPRINKLER SYSTEM (FEET) WITH SPRINKLER SYSTEM (FEET) W u . O N
SECTION1007 FLOOR. 3.DOORS WITH AUTOMATIC FLUSH BOLTS AS PERMITTED BY SECTION 1a1a,1,9,4, ITEM 3, N
EXIT AND EXIT ACCESS B 200 300 C O m � � ~ ui ti
4.DOORS FROM INDIVIDUAL DWELLING UNITS AND SLEEPING UNITS OF GROUP R OCCUPANCIES AS PERMITTED BY Z r-
DOORWAY CONFIGURATION 1010.1.2 DOOR SWING. b � d m
SECTION 1010.1.9.4, ITEM 4. F-1 200 250 m
EGRESS DOORS SHALL BE OFTHE PIVOTED OR SIDE-HINGED SWINGINGTYPF. S-2 300 400 Q m N H
1007.1 GENERAL.
101a.1.1a PANIC AND FIRE EXIT HARDWARE.
EXITS, EXIT ACCESS DOORWAYS,AND EXIT ACCESS STAIRWAYS AND RAMPS SERVING SPACES, INCLUDING INDIVIDUAL 1010.1.2.1 DIRECTION OF SWING. SWINGING DOORS SERVING A GROUP H OCCUPANCY AND SWINGING DOORS SERVING ROOMS OR SPACES WITH AN FOR SI: 1 FOOT= 304.8 MM.
BUILDING STORIES,SHALL BE SEPARATED IN ACCORDANCE WITH THE PROVISIONS OFTHIS SECTION. PIVOT OR SIDE-HINGED SWINGING DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING A OCCUPANT LOAD OF 50 OR MORE IN A GROUP A OR E OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK 8. SEETHE FOLLOWING SECTIONS FOR MODIFICATIONS TO EXIT ACCESS TRAVEL
1007.1.1 Two EXITS OR EXIT ACCESS DOORWAYS.
ROOM OR AREA CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR A GROUP H OCCUPANCY. OTHER THAN PANIC HARDWARE OR FIRE EXIT HARDWARE. DISTANCE REQUIREMENTS:
1017
WHERE TWO EXITS,EXIT ACCESS DOORWAYS, EXIT ACCESS STAIRWAYS OR RAMPS, OR ANY COMBINATION THEREOF, 1010.1.3 DOOR OPENIN SECTION .2.2: FOR INCREASED DISTANCE LIMITATION IN GROUPS F-1 AND S-1.
G FORCE. EXCEPTIONS: SECTION 1017.9: FOR PINCREASED WALKWAYS.
ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS,THEY SHALL BE PLACED A DISTANCE APART EQUAL TO NOT THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS, OTHER THAN FIRE DOORS,SHALL 1.A MAIN EXIT OF A GROUP A OCCUPANCY SHALL BE PERMITTED TO BE LOCKING IN ACCORDANCE WITH SECTION
LESS THAN ONE-HALF OFTHE LENGTH OFTHE MAXIMUM OVERALL DIAGONAL DIMENSION OFTHE BUILDING OR AREA NOT EXCEED 5 POUNDS(22 N),THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS 1010.1.9.4,ITEM 2.
TO BE SERVED MEASURED IN A STRAIGHT LINE BETWEEN THEM. INTERLOCKING OR SCISSOR STAIRWAYS SHALL BE OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FOR OTHER SWINGING DOORS,AS 2.DOORS PROVIDED WITH PANIC HARDWARE OR FIRE EXIT HARDWARE SERVING A GROUP A OR E OCCUPANCY SHALL In. BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN
COUNTED AS ONE EXIT STAIRWAY. WELL AS SLIDING AND FOLDING DOORS,THE DOOR LATCH SHALL RELEASE WHEN SUBJECTED TO A 15-POUND(67 N) BE PERMITTED TO BE ELECTRONICALLY LOCKED IN ACCORDANCE WITH SECTION 1010.1.9.9 OR 1010.1.9.10. ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. SEE SECTION 903 FOR OCCUPANCIES
FORCE.THE DOOR SHALL BE SET IN MOTION WHEN SUBJECTED TO A 30-POUND (133 N)FORCE.THE DOOR SHALL 3.0UTDOOR GATES FROM RESIDENTIAL AND COMMERCIAL SWIMMING POOLS OR SWIMMING POOL DECKS,EXCEPT WHERE AUTOMATIC SPRINKLER SYSTEMS ARE PERMITTED IN ACCORDANCE WITH SECTION
EXCEPTIONS: SWING TO A FULL-OPEN POSITION WHEN SUBJECTED TO A 15-POUND (67 N)FORCE. WHERE THE POOL DECK SERVES AS A PORTION OF THE MEANS OF EGRESS OF A BUILDING OR HAS AN OCCUPANT 903.3.1.2.
LOAD OF 300 OR GREATER.
1.WHERE INTERIOR EXIT STAIRWAYS OR RAMPS ARE INTERCONNECTED BY A 1-HOUR FIRE-RESISTANCE-RATED 1010.1.3.1 LOCATION OF APPLIED FORCES. c. BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN
CORRIDOR CONFORMING TO THE REQUIREMENTS OF SECTION 1020,THE REQUIRED EXIT SEPARATION SHALL BE FORCES SHALL BE APPLIED TO THE LATCH SIDE OFTHE DOOR. ELECTRICAL ROOMS WITH EQUIPMENT RATED 1,200 AMPERES OR MORE AND OVER 6 FEET(1829 MM)WIDE,AND THAT
MEASURED ALONG THE SHORTEST DIRECT LINE OF TRAVEL WITHIN THE CORRIDOR, CONTAIN OVERCURRENT DEVICES, SWITCHING DEVICES OR CONTROL DEVICES WITH EXIT OR EXIT ACCESS DOORS, ACCORDANCE WITH SECTION 903.3.1.1.
2.WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 1010 SHALL BE EQUIPPED WITH PANIC HARDWARE OR FIRE EXIT HARDWARE.THE DOORS SHALL SWING IN THE DIRECTION 1017.2.2 GROUP F-1 AND S-1 INCREASE. cl
SECTION 903.3.1.1 OR 903.3.1.2,THE SEPARATION DISTANCE SHALL BE NOT LESS THAN ONE-THIRD OF THE LENGTH OF DOORS, GATES AND TURNSTILES OF EGRESS TRAVEL, THE MAXIMUM EXIT ACCESS TRAVEL DISTANCE SHALL BE 400 FEET(122 M) IN GROUP F-1 OR S-1
THE MAXIMUM OVERALL DIAGONAL DIMENSION OFTHE AREA SERVED. 1010.1.10.1 INSTALLATION. OCCUPANCIES WHERE ALL OF THE FOLLOWING CONDITIONS ARE MET. (�1OL ,m
1010.1 DOORS. WHERE PANIC OR FIRE EXIT HARDWARE IS INSTALLED, IT SHALL COMPLY WITH THE FOLLOWING: LJ a)a)
3.IN GROUP R1 AND R2 OCCUPANCIES,THE DISTANCE BETWEEN EXITS IS NOT APPLICABLE TO COMMON NONLOOPED m
MEANS OF EGRESS DOORS SHALL MEET THE REQUIREMENTS OF THIS SECTION.DOORS SERVING A MEANS OF EGRESS 1.THE PORTION OF THE BUILDING CLASSIFIED AS GROUP F-1 OR S-1 IS LIMITED TO ONE STORY +- J m
EXIT ACCESS CORRIDORS IN A BUILDING THAT HAS CORRIDOR DOORS FROM THE GUESTROOM OR GUEST SUITE OR ca
SYSTEM SHALL MEET THE REQUIREMENTS OF THIS SECTION AND SECTION 1022.2. DOORS PROVIDED FOR EGRESS 1.PANIC HARDWARE SHALL BE LISTED IN ACCORDANCE WITH UL 305. IN HEIGHT, � �
DWELLING UNIT,WHICH ARE ARRANGED SO THAT THE EXITS ARE LOCATED IN OPPOSITE DIRECTIONS FROM SUCH 2.FIRE EXIT HARDWARE SHALL BE LISTED IN ACCORDANCE WITH UL 10C AND UL 305. 0 E �
DOORS. PURPOSES IN NUMBERS GREATER THAN REQUIRED BY THIS CODE SHALL MEET THE REQUIREMENTS OFTHIS SECTION, 2.THE MINIMUM HEIGHT FROM THE FINISHED FLOOR TO THE BOTTOM OF THE CEILING OR ROOF m ._ �i
FOR ACCESSIBILITY PROVISIONS RELATED TO DOORS, REFER TO THE FLORIDA BUILD ING CODE,ACCESSIBILITY. 3.THE ACTUATING PORTION OFTHE RELEASING DEVICE SHALL EXTEND NOT LESS THAN ONE-HALF OF THE DOOR LEAF SLAB OR DECK IS 24 FEET(7315 MM). -) ce)
WIDTH. 3.THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN 0 L_ N LL
1aa7.1.1.1 MEASUREMENT POINT. Ca •�
MEANS OF EGRESS DOORS SHALL BE READILY DISTINGUISHABLE FROM THE ADJACENT CONSTRUCTION AND FINISHES 4.THE MAXIMUM UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS(67 N), ACCORDANCE WITH SECTION 903.3.1.1. .7 C n ai
THE SEPARATION DISTANCE REQUIRED IN SECTION 1007.1.1 SHALL BE MEASURED IN ACCORDANCE WITH THE G v a)
FOLLOWING: SUCH THAT THE DOORS ARE EASILY RECOGNIZABLE AS DOORS. MIRRORS OR SIMILAR REFLECTING MATERIALS SHALL Q� . . 0 a)
NOT BE USED ON MEANS OF EGRESS DOORS. MEANS OF EGRESS DOORS SHALL NOT BE CONCEALED BY CURTAINS, 1010.1.10.2 BALANCED DOORS. c ._
1017.3 MEASUREMENT. Q - 0-
DRAPES,DECORATIONS OR SIMILAR MATERIALS. IF BALANCED DOORS ARE USED AND PANIC HARDWARE IS REQUIRED,THE PANIC HARDWARE SHALL BE THE PUSH-PAD m U
1.THE SEPARATION DISTANCE TO EXIT OR EXIT ACCESS DOORWAYS SHALL BE MEASURED TO ANY POINT ALONG THE EXIT ACCESS TRAVEL DISTANCE SHALL BE MEASURED FROM THE MOST REMOTE POINT OF EACH c
TYPE AND THE PAD SHALL NOT EXTEND MORE THAN ONE-HALF THE WIDTH OF THE DOOR MEASURED FROM THE LATCH N t0
WIDTH OF THE DOORWAY. 1010.1.1 SIZE OF DOORS. SIDE. ROOM, AREA OR SPACE ALONG THE NATURAL AND UNOBSTRUCTED PATH OF HORIZONTAL AND
THE REQUIRED CAPACITY OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND VERTICAL EGRESS TRAVEL TO THE ENTRANCE TO AN EXIT. c
23HE SEPARATION DISTANCE TO EXIT ACCESS STAIRWAYS SHALL BE MEASURED TO THE CLOSEST RISER. m
SHALL PROVIDE A MINIMU N M CLEAR OPEING WIDTH OF 32 INCHES(813 MM).THE CLEAR OPENING WIDTH OF U
DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP,WITH SECTION 1013 EXCEPTION. IN OPEN PARKING GARAGES, EXIT ACCESS TRAVEL DISTANCE IS PERMITTED TO
1007.1.2 THREE OR MORE EXITS OR EXIT ACCESS DOORWAYS. THE DOOR OPEN 90 DEGREES (1.57 RAD),WHERE THIS SECTION REQUIRES A MINIMUM CLEAR OPENING WIDTH OF 32 EXIT SIGNS BE MEASURED TO THE CLOSEST RISER OF AN EXIT ACCESS STAIRWAY OR THE CLOSEST
WHERE ACCESS TO THREE OR MORE EXITS IS REQUIRED, NOT LESS THAN TWO EXIT OR EXIT ACCESS DOORWAYS INCHES(813 MM)AND A DOOR OPEN ING INCLUDES TWO DOOR LEAVES WITHOUT A MULLION,ONE LEAF SHALL PROVIDE SLOPE OF AN EXIT ACCESS RAMP.
SHALL BE ARRANGED IN ACCORDANCE WITH THE PROVISIONS OF SECTION 1007.1.1.ADDITIONAL REQUIRED EXIT OR A MINIMUM CLEAR OPENING WIDTH OF 32 INCHES MM). IN GROUP 1-2,DOORS SERVING AS MEANS OF EGRESS 813
EXIT ACCESS DOORWAYS SHALL BE ARRANGED A REASONABLE DISTANCE APART SO THAT IF ONE BECOMES BLOCKED, ( 1013.1 WHERE REQUIRED_
THE OTHERS WILL BE AVAILABLE. DOORS WHERE USED FOR THE MOVEMENT OF BEDS SHALL PROVIDE A MINIMUM CLEAR OPENING WIDTH OF411/2 EXITS AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN READILY VISIBLE FROM ANY
INCHES(1054 MM).THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE 48 INCHES (1219 MM)NOMINAL.THE DIRECTION OF EGRESS TRAVEL.THE PATH OF EGRESS TRAVEL TO EXITS AND WITHIN EXITS SHALL BE MARKED BY SECTION 1018 cn
1007.1.3 REMOTENESS OF EXIT ACCESS STAIRWAYS OR RAMPS. MINIMUM CLEAR HEIGHT OF DOOR OPENINGS SHALL BE NOT LESS THAN 80 INCHES(2032 MM), READILY VISIBLE EXIT SIGNS TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL IN CASES WHERE THE EXIT OR AISLES m
WHERE TWO EXIT ACCESS STAIRWAYS OR RAMPS PROVIDE THE REQUIRED MEANS OF EGRESS TO EXITS ATANOTHER THE PATH OF EGRESS TRAVEL IS NOT IMMEDIATELY VISIBLE TO THE OCCUPANTS. INTERVENING MEANS OF EGRESS 0-
1010.1.1.1 PROJECTIONS INTO CLEAR WIDTH. 1a18.1 GENERAL_
X
DOORS WITHIN EXITS SHALL BE MARKED BY EXIT SIGNS, EXIT SIGN PLACEMENT SHALL BE SUCH THAT NO POINT IN AN
STORY,THE REQUIRED SEPARATION DISTANCE SHALL BE MAINTAINED FOR ALL PORTIONS OF SUCH EXIT ACCESS THERE SHALL NOT BE PROJECTIONS INTO THE REQUIRED CLEAR OPEN ING WIDTH LOWER THAN 34 INCHES 864 MM AISLES AND AISLE ACCESSWAYS SERVING AS A PORTION OF THE EXIT ACCESS IN THE MEANS OF EGRESS SYSTEM
STAIRWAYS OR RAMPS. ( ) EXIT ACCESS CORRIDOR OR EXIT PASSAGEWAY IS MORE THAN 100 FEET(30 480 MM)OR THE LISTED VIEWING SHALL COMPLY WITH THE REQUIREMENTS OF THIS SECTION.AISLES OR AISLE ACCESSWAYS SHALL BE PROVIDED w
ABOVE THE FLOOR OR GROUND,PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES(864 MM)AND 8a
INCHES(2a32 MM)ABOVE THE FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES(1 02 MM), FROM ALL OCCUPIED PORTIONS OF THE EXIT ACCESS THAT CONTAIN SEATS,TABLES, FURNISHINGS,DISPLAYS AND
1007.1.3.1THREE OR MORE EXIT ACCESS STAIRWAYS OR RAMPS. DISTANCE FOR THE SIGN,WHICHEVER IS LESS,FROM THE NEAREST VISIBLE EXIT SIGN. SIMILAR FIXTURES OR EQUIPMENT.THE MINIMUM WIDTH OR REQUIRED CAPACITY OF AISLES SHALL BE Q)
WHERE MORE THAN TWO EXIT ACCESS STAIRWAYS OR RAMPS PROVIDE THE REQU IRED MEANS OF EGRESS,NOT LESS EXCEPTIONS: UNOBSTRUCTED, cn
THAN TWO SHALL BE ARRANGED IN ACCORDANCE WITH SECTION 1007,1,3, EXCEPTION: DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES(1980 MM)MINIMUM ABOVE THE 1.EXIT SIGNS ARE NOT REQUIRED IN ROOMS OR AREAS THAT REQUIRE ONLY ONE EXIT OR EXIT ACCESS. m
FLOOR. 2.MAIN EXTERIOR EXIT DOORS OR GATES THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS NEED NOT HAVE Jr-
EXIT SIGNS WHERE APPROVED BY THE BUILDING OFFICIAL. EXCEPTION:ENCROACHMENTS COMPLYING WITH SECTION 1005.7. 0-
SECTION1008 1010.1.2 DOOR SWING. 3.EXIT SIGNS ARE NOT REQUIRED IN OCCUPANCIES IN GROUP U AND INDIVIDUAL SLEEPING UNITS OR DWELLING UNITS i
MEANS OF EGRESS ILLUMINATION EGRESS DOORS SHALL BE OF THE PIVOTED OR SIDE-HINGED SWINGING TYPE. IN GROUP R-1, R-2 OR R-3. 1018.2 AISLES IN ASSEMBLY SPACES.
4.EXIT SIGNS ARE NOT REQUIRED IN DAYROOMS, SLEEPING ROOMS OR DORMITORIES IN OCCUPANCIES IN GROUP 3. AISLES AND AISLE ACCESSWAYS SERVING A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES SHALL COMPLY WITH S-
SECTION 1029. 0
1008.1 MEANS OF EGRESS ILLUMINATION. 1010.1.2.1 DIRECTION OF SWING.
5.IN OCCUPANCIES IN GROUPS A-4 AND A-5, EXIT SIGNS ARE NOT REQUIRED ON THE SEATING SIDE OF VOMITORIES OR
ILLUMINATION SHALL BE PROVIDED IN THE MEANS OF EGRESS IN ACCORDANCE WITH SECTION 1008.2.UNDER PIVOT OR SIDE-HINGED SWINGING DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING A OPENINGS INTO SEATING AREAS WHERE EXIT SIGNS ARE PROVIDED IN THE CONCOURSE THATARE READILY L
EMERGENCY POWER, MEANS OF EGRESS ILLUMINATION SHALL COMPLY WITH SECTION 1008.3. ROOM OR AREA CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR A GROUP H OCCUPANCY. APPARENT FROM THE VOMITORIES,EGRESS LIGHTING IS PROVIDED TO IDENTIFY EACH VOMITORY OR OPENING WITHIN 1018.3 AISLES IN GROUPS B AND M. UI
THE SEATING AREA IN AN EMERGENCY. IN GROUP B AND M OCCUPANCIES,THE MINIMUM CLEAR AISLE WIDTH SHALL BE DETERMINED BY SECTION 1005.1 FOR a-j
1008.2 ILLUMINATION REQUIRED. 1010.1.3 DOOR OPENING FORCE. THE OCCUPANT LOAD SERVED, BUT SHALL BE NOT LESS THAN THAT REQUIRED FOR CORRIDORS BY SECTION 1020 2. m
THE MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE ILLUMINATED AT ALL TIMES THATTHE ROOM OR SPACE THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS, OTHER THAN FIRE DOORS,SHALL 1013.3 ILLUMINATION. 0 (.0
IS OCCUPIED. NOT EXCEED 5 POUNDS(22 N).THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED, EXCEPTION:NONPUBLIC AISLES SERVING LESS THAN 50 PEOPLE AND NOT REQUIRED TO BE ACCESSIBLE BY m _. a
OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FOR OTHER SWINGING DOORS,AS CHAPTER 11 NEED NOT EXCEED 28 INCHES(711 MM) IN WIDTH. m CO
1008.2.1 ILLUMINATION LEVEL UNDER NORMAL POWER. WELL AS SLIDING AND FOLDING DOORS,THE DOOR LATCH SHALL RELEASE WHEN SUBJECTED TO A 15-POUND(67 N) EXCEPTION:TACTILE SIGNS REQUIRED BY SECTION 1013.4 NEED NOT BE PROVIDED WITH ILLUMINATION. 1018.4 AISLE ACCESSWAYS IN GROUP M. V 'LD LD LL
THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL BE NOT LESS THAN 1 FOOTCANDLE(1 1 LUX)ATTHE WALKING FORCE.THE DOOR SHALL BE SET IN MOTION WHEN SUBJECTED TO A 30-POUND (133 N)FORCE,THE DOOR SHALL L 0
SURFACE. SWING TO A FULL-OPEN POSITION WHEN SUBJECTED TO A 15-POUND(67 N)FORCE. 1013,5 INTERNALLY ILLUMINATED EXIT SIGNS, AN AISLE ACCESSWAY SHALL BE PROVIDED ON NOT LESS THAN ONE S IDE OF EACH ELEMENT WITHIN THE ai Q) J 0
MERCHANDISE PAD,THE MINIMUM CLEAR WIDTH FOR AN AISLE ACCESSWAY NOT REQUIRED TO BE ACCESSIBLE SHALL E > 6) a
ELECTRICALLY POWERED, SELF-LUMINOUS AND PHOTOLUMINESCENT EXIT SIGNS SHALL BE LISTED AND LABELED IN BE 30 INCHES(762 MM).THE REQUIRED CLEAR WIDTH OF THE AISLE ACCESSWAY SHALL BE MEASURED (Q
EXCEPTION:FOR AUDITORIUMS,THEATERS, CONCERT OR OPERA HALLS AND SIMILAR ASSEMBLY OCCUPANCIES,THE 1010.1.3.1 LOCATION OF APPLIED FORCES. ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS Z C �; 1`
ILLUMINATION ATTHE WALKING SURFACE IS PERMITTED TO BE REDUCED DURING PERFORMANCES BY ONE OFTHE FORCES SHALL BE APPLIED TO THE LATCH SIDE OFTHE DOOR. AND CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED AT ALLTIMES. PERPENDICULAR TO THE ELEMENTS AND MERCHANDISE WITHIN THE MERCHANDISE PAD.THE 30 INCH(762 MM) 2-1 � o
MINIMUM CLEAR WIDTH SHALL BE MAINTAINED TO PROVIDE A PATH TO AN ADJACENT AISLE OR AISLE ACCESSWAY.
FOLLOWING METHODS PROVIDED THAT THE REQUIRED ILLUMINATION IS AUTOMATICALLY RESTORED UPON •o
ACTIVATION OF A PREMISES' FIRE ALARM SYSTEM: 1010.1.5 FLOOR ELEVATION. THE COMMON PATH OF EGRESS TRAVEL SHALL NOT EXCEED 30 FEET(9144 MM)FROM ANY POINT IN THE .
THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR. SUCH FLOOR OR LANDING SHALL BE AT THE SAME SECTION 1013 MERCHANDISE PAD.
1.EXTERNALLY ILLUMINATED WALKING SURFACES SHALL BE PERMITTED TO BE ILLUMINATED TO NOT LESS THAN 0.2 ELEVATION ON EACH SIDE OFTHE DOOR.LANDINGS SHALL BE LEVEL EXCEPT FOR EXTERIOR LANDINGS,WHICH ARE EXIT SIGNS
FOOTCANDLE(2.15 LUX). PERMITTED TO HAVE A SLOPE NOT TO EXCEED 0.25 UNIT VERTICAL IN 12 UNITS HORIZONTAL(2-PERCENT SLOPE). EXCEPTION:FOR AREAS SERVING NOT MORE THAN 50 OCCUPANTS,THE COMMON PATH OF EGRESS TRAVEL
2.STEPS, LANDINGS AND THE SIDES OF RAMPS SHALL BE PERMITTED TO BE MARKED WITH SELF-LUMINOUS MATERIALS SHALL NOT EXCEED 75 FEET(22 860 MM),
IN ACCORDANCE WITH SECTIONS 1025.2.1, 1025.2.2 AND 1025.2.4 BY SYSTEMS LISTED IN ACCORDANCE WITH UL 1994. EXCEPTIONS: 1015.1 GENERAL.
1.DOORS SERVING INDIVIDUAL DWELLING UNITS IN GROUPS R-2 AND R-3 WHERE THE FOLLOWING APPLY: GUARDS SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1015.2 THROUGH 1015.7. OPERABLE WINDOWS WITH 1018.5 AISLES IN OTHER THAN ASSEMBLY SPACES AND GROUPS B AND M.
1008.2.2 GROUP 1-2. 1,1,A DOOR IS PERMITTED TO OPEN AT THE TOP STEP OF AN INTERIOR FLIGHT OF STAIRS,PROVIDED THE DOOR SILLS LOCATED MORE THAN 72 INCHES (1829 MM)ABOVE FINISHED GRADE OR OTHER SURFACE BELOW SHALL COMPLY IN OTHER THAN ROOMS OR SPACES USED FOR ASSEMBLY PURPOSES AND GROUP B AND M OCCUPANCIES,THE
IN GROUP 1-2 OCCUPANCIES WHERE TWO OR MORE EXITS ARE REQUIRED,ON THE EXTERIOR LANDINGS REQUIRED BY DOES NOT SWING OVER THE TOP STEP. WITH SECTION 1015,8, MINIMUM CLEAR AISLE CAPACITY SHALL BE DETERMINED BY SECTION 1005.1 FOR THE OCCUPANT LOAD SERVED,BUT
SECTION 1010.6.1,MEANS OF EGRESS ILLUMINATION LEVELS FOR THE EXIT DISCHARGE SHALL BE PROVIDED SUCH 1.2.SCREEN DOORS AND STORM DOORS ARE PERMITTED TO SWING OVER STAIRS OR LANDINGS. THE WIDTH SHALL BE NOT LESS THAN THAT REQUIRED FOR CORRIDORS BY SECTION 1a20,2,
THAT FAILURE OF ANY SINGLE LIGHTING UNIT SHALL NOT REDUCE THE ILLUMINATION LEVEL ON THAT LANDING TO 2,EXTERIOR DOORS AS PROVIDED FOR IN SECTION 1003.5, EXCEPTION 1,AND SECTION 1022.2,WHICH ARE NOT ON AN 1015.2 WHERE REQUIRED.
LESS THAN 1 FOOTCANDLE (11 LUX). ACCESSIBLE ROUTE, GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES, INCLUDING MEZZANINES,EQUIPMENT EXCEPTION:NONPUBLIC AISLES SERVING LESS THAN 50 PEOPLE AND NOT REQUIRED TO BE ACCESSIBLE BY
3.I111 GROUP R-3 OCCUPANCIES NOT REQUIRED TO BE ACCESSIBLE UNITS,THE LANDING AT AN EXTERIOR DOORWAY PLATFORMS,AISLES, STAIRS, RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN 30 INCHES (762 MM)MEASURED CHAPTER 11 NEED NOT EXCEED 28 INCHES(711 MM) IN WIDTH.
1a08.2.3 EXIT DISCHARGE. SHALL BE NOT MORE THAN 73/4 INCHES(197 MM)BELOW THE TOP OF THE THRESHOLD,PROVIDED THE DOOR,OTHER VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36 INCHES (914 MM)HORIZONTALLYTO THE EDGE
ILLUMINATION SHALL BE PROVIDED ALONG THE PATH OF TRAVEL FOR THE EXIT DISCHARGE FROM EACH EXITTO THE THAN AN EXTERIOR STORM OR SCREEN DOOR, DOES NOT SWING OVER THE LANDING. OF THE OPEN S IDE. GUARDS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT IN ACCORDANCE WITH SECTION
PUBLIC WAY. 1607.8. SECTION 1022
4,VARIATIONS IN ELEVATION DUE TO DIFFERENCES IN FINISH MATERIALS,BUT NOT MORE THAN 1/2 INCH(12,7 MM). EXITS
5.RESERVED. EXCEPTION:GUARDS ARE NOT REQUIRED FOR THE FOLLOWING LOCATIONS:
EXCEPTION: ILLUMINATION SHALL NOT BE REQUIRED WHERE THE PATH OF EXIT DISCHARGE MEETS BOTH OFTHE 6.DOORS SERVING EQUIPMENT SPACES NOT REQUIRED TO BE ACCESSIBLE IN ACCORDANCE WITH CHAPTER 11 AND 1022.1 GENERAL.
FOLLOWING REQUIREMENTS: SERVING AN OCCUPANT LOAD OF FIVE OR LESS SHALL BE PERMITTED TO HAVE A LANDING ON ONE SIDE TO BE NOT 1.ON THE LOADING SIDE OF LOADING DOCKS OR PIERS. EXITS SHALL COMPLY WITH SECTIONS 1022 THROUGH 1027 AND THE APPLICABLE REQUIREMENTS OF SECTIONS 1003
1.THE PATH OF EXIT DISCHARGE IS ILLUMINATED FROM THE EXIT TO A SAFE DISPERSAL AREA COMPLYING WITH 101 5,3 HEIGHT,
MORE THAN 7 INCHES (179 MM)ABOVE OR BELOW THE LANDING ON THE EGRESS SIDE OFTHE DOOR, THROUGH 1 01 5.AN EXIT SHALL NOT BE USED FOR ANY PURPOSE THAT INTERFERES WITH ITS FUNCTION AS A MEANS >_
REQUIRED GUARDS SHALL BE NOT LESS THAN 42 INCHES (1067 MM)HIGH,MEASURED VERTICALLY AS FOLLOWS: OF EGRESS.ONCE A GIVEN LEVEL OF EXIT PROTECTION IS ACHIEVED,SUCH LEVEL OF PROTECTION SHALL NOT BE U)
SECTION 1028.5. 1010.1.6 LANDINGS AT DOORS. REDUCED UNTIL ARRIVAL AT THE EXIT DISCHARGE.EXITS SHALL BE CONTINUOUS FROM THE POINT OF ENTRY INTO J
2,A DISPERSAL AREA SHALL BE ILLUMINATED TO A LEVEL NOT LESS THAN 1 FOOTCANDLE(11 LUX)AT THE WALKING LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR,WHICHEVER IS THE EXIT TO THE EXIT DISCHARGE. Q
SURFACE, GREATER.DOORS IN THE FULLY OPEN POSITION SHALL NOT REDUCE A REQUIRED DIMENSION BY MORE THAN 7 1.FROM THE ADJACENT WALKING SURFACES. Z
INCHES(1 78 MM),WHERE A LANDING SERVES AN OCCUPANT LOAD OF 50 OR MORE,DOORS IN ANY POSITION SHALL 2.ON STAIRWAYS AND STEPPED AISLES,FROM THE LINE CONNECTING THE LEADING EDGES OFTHE TREAD NOSINGS, 1022.2 EXTERIOR EXIT DOORS. Q
1008.3 EMERGENCY POWER FOR ILLUMINATION. NOT REDUCE THE LANDING TO LESS THAN ONE-HALF ITS REQUIRED WIDTH.LANDINGS SHALL HAVE A LENGTH 3.ON RAMPS AND RAMPED AISLES,FROM THE RAMP SURFACE ATTHE GUARD. BUILDINGS OR STRUCTURES USED FOR HUMAN OCCUPANCY SHALL HAVE NOT LESS THAN ONE EXTERIOR DOOR THAT LL.I
THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES' MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES(1118 MM). MEETS THE REQUIREMENTS OF SECTION 1010.1.1.
ELECTRICAL SUPPLY. 1015.4 OPENING LIMITATIONS. O
EXCEPTION: LANDING LENGTH IN THE DIRECTION OF TRAVEL IN GROUPS R-3 AND U AND WITHIN INDIVIDUAL UNITS OF REQUIRED GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4 INCHES(102 MM)IN DIAMETER FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT 0
, 1022.2.1 DETAILED REQUIREMENTS.
1008.3.1 GENERAL. GROUP R-2 NEED NOT EXCEED 36 INCHES (914 MM). EXTERIOR EXIT DOORS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTION 10101, ai (D
IN THE EVENT OF POWER SUPPLY FAILURE IN ROOMS AND SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS,
Z 0
AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS: 1010.1.7 THRESHOLDS. EXCEPTIONS: 1022.2.2 ARRANGEMENT.
THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 3/4 INCH(19,1 MM)IN HEIGHT ABOVE THE FINISHED FLOOR OR 1.FROM A HE IGHT OF 36 INCHES(914 MM)TO 42 INCHES(1 a67 MM), GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW EXTERIOR EXIT DOORS SHALL LEAD DIRECTLY TO THE EXIT DISCHARGE OR THE PUBLIC WAY. 0) J
1.AISLES. LANDING FOR SLIDING DOORS SERVING DWELLING UNITS OR 1/2 INCH (12.7 MM)ABOVE THE FINISHED FLOOR OR PASSAGE OF A SPHERE 43/8 INCHES (111 MM)IN DIAMETER. 5 D
2.CORRIDORS. LANDING FOR OTHER DOORS.RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1/4 INCH(6.4 MM)AT ` m
3.EXIT ACCESS STAIRWAYS AND RAMPS, DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL 2.THE TRIANGULAR OPENINGS AT THE OPEN SIDES OF A STAIR, FORMED BY THE RISER,TREAD AND BOTTOM RAIL SECTION 1028 O
(50-PERCENT SLOPE). SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES(152 MM)IN DIAMETER. EXIT DISCHARGE
1008.3.2 BUILDINGS. 3.AT ELEVATED WALKING SURFACES FOR ACCESS TO AND USE OF ELECTRICAL, MECHANICAL OR PLUMBING SYSTEMS
IN THE EVENT OF POWER SUPPLY FAILURE IN BUILDINGS THAT REQUIRE TWO OR MORE MEANS OF EGRESS,AN EXCEPTIONS: OR EQUIPMENT,GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 21 INCHES(533 MM)IN 1028.1 GENERAL.
EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OFTHE FOLLOWING AREAS: 1.IN OCCUPANCY GROUP R-2 OR R-3,THRESHOLD HEIGHTS FOR SLIDING AND SIDE-HINGED EXTERIOR DOORS SHALL D IAMETER. EXITS SHALL DISCHARGE D IRECTLY TO THE EXTERIOR OF THE BUILDING,THE EXIT DISCHARGE SHALL BE AT GRADE OR
BE PERMITTED TO BE UP TO 73/4 INCHES(197 MM) IN HEIGHT IF ALL OF THE FOLLOWING APPLY: 4.IN AREAS THAT ARE NOT OPEN TO THE PUBLIC WITHIN OCCUPANCIES IN GROUP 1-3,F,H OR S,AND FOR SHALL PROVIDE A DIRECT PATH OF EGRESS TRAVEL TO GRADE.THE EXIT DISCHARGE SHALL NOT REENTER A
1.INTERIOR EXIT ACCESS STAIRWAYS AND RAMPS. 1,1,THE DOOR IS NOT PART OF THE REQUIRED MEANS OF EGRESS, ALTERNATING TREAD DEVICES AND SHIP'S LADDERS, GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF BUILDING.THE COMBINED USE OF EXCEPTIONS 1 AND 2 SHALL NOT EXCEED 50 PERCENT OF THE NUMBER AND 0
2.1NTERIOR AND EXTERIOR EXIT STAIRWAYS AND RAMPS. A SPHERE 21 INCHES(533 MM)IN DIAMETER. MINIMUM WIDTH OR REQUIRED CAPACITY OF THE REQUIRED EXITS. 0 N o
1.2.THE DOOR IS NOT PART OF AN ACCESSIBLE ROUTE AS REQUIRED BY CHAPTER 11. N N 0
3.EXIT PASSAGEWAYS. 2.FOR EXTERIOR DOORS SERVING DWELLING UNITS,OR SLEEPING UN ITS,THRESHOLDS AT DOORWAYS SHALL NOT N ti
4.VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE USED FOR EXIT DISCHARGE IN ACCORDANCE WITH 1015.6 MECHANICAL EQUIPMENT,SYSTEMS AND DEVICES. � ` d Q
EXCEED THE HEIGHT REQUIRED TO PASS THE WATER RESISTANCE TEST OF AAMA/WDMA/CSA 101/I.S,2/A440,ORTAS GUARDS SHALL BE PROVIDED WHERE VARIOUS COMPONENTS THAT REQUIRE SERVICE ARE LOCATED WITHIN 10 FEET SECTION 1028 a) LO -
SECTION 1028.1. 202 FOR HIGH-VELOCITY HURRICANE ZONES,OR THE MAXIMUM ALLOWABLE HEIGHT DIFFERENCE BETWEEN INTERIOR EXIT DISCHARGE a) 1 -0 � F_5.EXTERIOR LANDINGS AS REQUIRED BY SECTION 1010.1.6 FOR EXIT DOORWAYS THAT LEAD DIRECTLYTO THE (3a48 MM)OF A ROOF EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE _c E a)
FLOOR LEVELS.EXTERIOR FLOOR LEVEL SHALL COMPLY WITH TABLE 1a1 a.1.7. THAN 30 INCHES 762 MM ABOVE THE FLOOR,ROOF OR GRADE BELOW.THE GUARD SHALL EXTEND NOT LESS THAN 30 {CONTINUED ON GNUS) E z m
EXIT DISCHARGE. ( )
INCHES(762 MM)BEYOND EACH END OF SUCH COMPONENTS.THE GUARD SHALL BE CONSTRUCTED SO AS TO Z r V C)
N
PREVENT THE PASSAGE OF A SPHERE 21 INCHES (533 MM)IN DIAMETER. l� a�0 0
d d O