HomeMy WebLinkAboutA LS-110 LIFE SAFETY SYMBOLS LIFE SAFETY NOTES WALL TYPE LEGEND
L N
w ti
c m E a O
v L a LC7 �
FIRE PROTECTION SYSTEMS NOTE. FIRE ALARM SYSTEM AND DEVICES SYMBOL DESCRIPTION 8 m p
WALL MOUNTED FIRE EXTINGUISHER SHOWN ARE FOR GENERAL REFERENCE, FINAL DESIGN PERLICENSED OCCUPANCY LOAD BASED ON (FBC 2020 CHAPTER 10, TABLE 1004.1.1)SEE OCCUPANCY G.C. SHALL ENSURE EMERGENCY LIGHTS MEET OR EXCEED MINIMUM ILLUMINATION Q
PIRE PROTECTION CONTRACTOR UNDER SEPERATE PERMIT CALCULATIONS LISTED ON COVER SHEET CV-1 REQUIREMENTS PER FBC 2020 & FLORIDA FIRE PREVENTION CODE 2020.
F.E. _ _ _ NEW METAL BUILDING WALL/WINDOW ASSEMBLY- PER BUILDING 3 =
c 4 a
MANUFACTURER APPROVED SHOP DRAWINGS & STRUCTURAL E m
MAUNAL PULL FIRE ALARM STATION EGRESS DOORS SHALL OPEN IN THE DIRECTION OF EGRESS. (7.2.1.4.2) EMERGENCY ILLUMINATION SHALL BE PROVIDED. (7.9.1.1)(13.2.9) DRAWINGS / SPECIFICATIONS N If a
DIRECTION OF EGRESS
F❑ (PER FIRE PROTECTION SYSTEMS EGRESS DOORS SHALL HAVE PANIC HARDWARE. (13.2.2.2.4) RELEASE MECHANISMS ON = °
DESIGN&SPECIFICATIONS)
DOORS SHALL BE MOUNTED BETWEEN 34" AND 48"A.F.F. (7.2.1.7.1) THE FLOORS AND OTHER WALKING SURFACES WITHIN AN EXIT AND WITHIN THE PORTIONS —®— — _ NEW METAL BUILDING WALL / STRUCTURAL COLUMN ASSEMBLY-PER m ~
FIRE ALARM HORN/STROBE STATION OF THE EXIT ACCESS AND EXIT DISCHARGE DESIGNATED IN 7.8.1 .1 SHALL BE ILLUMINATED BUILDING MANUFACTURER& STRUCTURAL DRAWINGS / SPECIFICATIONS N L = E
PATH OF TRAVEL FS ( ( ) L 1 " ° w a
PER FIRE PROTECTION SYSTEMS DURING ITS SWING ANY DOOR IN A MEANS OF EGRESS SHALL LEAVE NOT LESS THAN AS FOLLOWS: 2 THE MINIMUM ILLUMINATION FOR FLOORS AND WALKING SURFACES, z
DESIGN&SPECIFICATIONS) ONE-HALF OF THE REQUIRED WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY,OR OTHER THAN NEW STAIRS DURING CONDITIONS OF STAIR USE, SHALL BE TO VALUES OF AT g � r aS u
LANDING UNOBSTRUCTED AND SHALL PROJECT NOT MORE THAN 7" INTOTHE REQUIRED LEAST 1 FT-CANDLE (10.8 LUX), MEASURED AT THE FLOOR. (3)IN ASSEMBLY NEW INTERIOR FRAMED WALL: 3 %" or 6" METAL STUDS @ 16" O.C. TYP. w/(1)
N 60 p
LAYER 5/"GYPSUM BOARD SHEATHING EACH SIDE OF WALL - DETAILS ON y � y 0 m
WIDTH . (7.2.1.4.3.1) OCCUPANCIES, THE ILLUMINATION OF THE WALKING SURFACES OF EXITACCESS SHALL L � . -2 Z)
75
BE AT LEAST 0.2 FT-CANDLE (2.2 LUX) DURING PERIODS OF PERFORMANCES OR SHEETS A 5,01 &A 5.02 s .6
EXIT LIGHT SYMBOLS THE FORCE REQUIRED TO OPEN ANY DOOR MANUALLY IN A MEANS OF EGRESS SHALL PROJECTIONS INVOLVING DIRECT LIGHT. 0
z °
NOT EXCEED 154 TO RELEASE THE LATCH AND 30#TO SET THE DOOR IN MOTION. NEW INSULATED INTERIOR PARTITION - COORDINATE ASSEMBLY TYPE WITH
(7.2.1.4.5) TACTILE EXIT SIGNAGE MOUNTED AT 60" A.F.F. LATCH SIDE OF THE DOOR. TYPICAL PARTITON DETAILS ON SHEETS A-5.01 &A-5.02 O
ILLUMINATED DIRECTIONAL EXIT SIGNAGE, CEILING MOUNTED OPENING FORCE FOR INTERIOR DOORS WITHOUT CLOSERS SHALL NOT EXCEED 54. BUILDING ADDRESS NUMBERS SHALL BE PLACED ON IN A VISIBLE LOCATION ON THE C ) V. -Lo
PRIMARY FACADE. LETTERS SHALL BE A MINIMUM OF 6" IN HEIGHT AND SHALL CONTRAST ,Q pO �y
DEAD END CORRIDORS SHALL NOT EXCEED 50 FEET. WITH THE WALL FINISH WHERE THEY ARE AFFIXED. � V
ILLUMINATED EXIT SIGNAGE, CEILING MOUNTED NOTE: 0 � C\,
0 6
1
COMMON PATHS OF TRAVEL SHALL NOT EXCEED 100 FEET. ALL CONSTRUCTION, DEMOLITION AND RENOVATION SHALL COMPLY WITH REQUIREMENTS EMERGENCY LIGHTING NOT SHOWN ON LIFE SAFETY PLANS INDICATED ON ELECTRICAL LIGHTING C!3 U. Q Q o
OF NFPA 241: STANDARDS FOR SAFEGUARDING CONSTRUCTION, ALTERATION,AND SYSTEMS PLANS -SHEETS E-3.1 THRU E-3.6 Z 0 ~y I Q o
LU
EMERGENCY LIGHTING NOTE: TRAVEL DISTANCE TO AN EXIT SHALL BE LESS THAN 250'. DEMOLITION OPERATIONS, 2017 EDITION. Q
EMERGENCY LIGHTING NOT SHOWN ON LIFE SAFETY PLANS INDICATED ON ELECTRICAL LIGHTING {,
SYSTEMS PLANS - SHEETS E-3.1 THRU E-3.6 AISLES SHALL NOT BE LESS THAN 36". A KNOX-BOX SHALL BE MOUNTED TO EXTERIOR WALL ADJACENT TO FRONT ENTRY DOORS
- COORDINATE TYPE AND FINISH WITH OWNER AND ARCHITECT PRIOR TO PURCHASE AND O
MANUAL FIRE EXTINGUISHER LOCATIONS MOUNTED WITH OPERABLE CONTROLS AT48" INSTALLATION. COORDINATE MOUNTING WITH MANUFACTURER SPECIFICATIONS.
A.F.F. -MAXIMUM SPACING 75'-0".
ALL INTERIOR WALL & CEILING FINISHES TO BE CLASS "C" FINISH MATERIALS AND SHALL Digitally signed by
FIRE EXTINGUISHERS SHALL BE CURRENTLY DATED AND TAGGED BY A LICENSED FIRE MEET MINIMUM APPLICABLE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE; ~ Brent Brent A.Wood
EQUIPMENT COMPANY. SECTION 803 &TABLE 803.9. LU DN:cn=Brent A.Wood,
C/) o=Brent A.Wood
JA. Architecture,LLC.,
G.C. SHALL ENSURE ALL NEW LIFE SAFETY DEVICES MEET OR EXCEED MINIMUM ou=Architecture,
REQUIREMENTS OF THE FIRE PREVENTION CODE 2017. Q email=erick@bawoodar
,c=US
WOO
Date:2
Date: 021.05.08
16:05:22-04'00'
G Vl
I�
U] rTl
W
� o �
o
LU C)
� Lq
Lq
e e e o r 7 ti
z LL
r ST LU CI E BLVD / COUNTY ROAD 608 - o rz
CD Z U
Q N
a/ Z w �
� � � W CA
S 89° 51' 31" E 1334.00' 8 � �
LAO
? EXISTING
J ACCESS
U D RIVE
R/W LINE Q R/W LINE R/W LINE
75
le
XISTING 25'-0" LANDSCAPE BUFFER 25'-0" LANDSCAPE BUFFER 25'-0" LANDSCAPE BUFFER
ACCESS �-
DRIVE 0
L
J adi
SKIN /STRAKES GJDCOAT H �j � .� `J`
NEW BOOTH PROCESS AISLEWAY c ' ` '�"� '�"�I �� ROCESS AISLEWAY .L
C m I 181 _-IA-L:��
CONCRETE GFAND > O c
' RECEIVEING TRAKES c = _ _ _ _ _ _ _ B H m �
- - _ U co LL
AREA I 15'-0" x 55'-0" NEW
DIP POOL /QC CONCRETE
PROCESS AISLEWAY PROCESS AISLEWAY SS AISLEWAY RECEIVEINGJ_ U
AREA
� 0 0 0
PHASE I I BUILDING ADD TION w Q DECLINED
�j 850'X 125'MANUFAC RING Sam
ER PROCESS WAREHOUSE > z TRUCK
~ ~ ±106,626 SQ. FT. Q P AY Q WELL 42"HIGH GUARD RAILING
Q PROCESS AISLEWAY
U Uj ALONG SIDES Or TRUCK WELL x
W W w
0 GRIND FUTU 0 _
BOOTH BOOTH BOOTH I O � == == == == == _ Q)
Z w = = ARto E __
¢ �
a
N
LLI
aQ
Q0 O
LU ~ �_
w 0
Z J
m
C] c�
EXISTING
EXISTING m m
CONCRETE . V A Z 7 C0
ACCESS RECEIVEING EXISTING U � 'L
DRIVE AREA CONCRETE aS (D v
RECEIVEING E > cn
AREA z �,
- (SEE CIVIL PLANS) Li
'o
d
❑ • EXISTING
COVERED NEW
EXISTING COVERED PATIO I W WAREHOUSE AREA
• • PATIO ¢ o 01
Qw
z CONCRETE WALK Q
06
3: o
— CONCRETE WALK — — — — — — — — — CONCRETE WALK — — — — �QNG
Z
� a
o_ o_
EXISTING EXISTING ASPHALT 0
o NEW ASPHALT PARKING o NEW ASPHALT PARKING NEW ASPHALT PARKING
ACCESS o LOT&ACCESS DRIVES o LOT&ACCESS DRIVES LOT&ACCESS DRIVES O
PARKING LOT&ACCESS
DRIVE DRIVES o o
0 o J
i J
Qi
E W
O
p
Q
r �
OVERALL SITE LIFE SAFETY PLAN 1 N
SCALE: 1/32" = V-0" LS-1.1Q vJ c
J L
NORTH z z m
a m p o
p 0 N
d d