2020-0562E5-1-E5-1
PHASE 2 PHASE 2 EM INTERIOR EXTERIOR INTERIOR rEIV11 m EM M2 EM M3LO EM M4 mom a _M � o U� L a O -= N N � � PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL Y = m MDP1 1200 A METER METER 1200 A MDP2 "21-4" "2L3" "2A" "2B" "2C" "2G" MAIN MAIN "2D" "2E" "2F" 0*2L1" "2L2" 0*21-5" ` LU FPUA TVSS O TVSS O - 7 7 7 7 7 7 GFCI CT O TRANSFORMER O CT GFCI 7 7 7 7 7 7 ~ O O O O O O _� -� 1200A 277/480V 1200A 3@0 0 0 XFMR XFMR T1 A MDPl-11 MDP2-11 T1 A _ �; n 2 MDP1- o �_� � � a MDP1- V s s m � N MDP1- MDP1- � INV. INV. MDP2- MDP2- MDP2- t U O 4-#4/0 & 1#2G IN 2-1/2" 1 1 4- 4 0 & 1 2G IN 2-1/2" FF °' Q`� � � N M Z o '7 #2 IN 3/4" #2 IN 3/4" O SCHEDULE 40 PVC SCHEDULE 40 PVC II 3#2 & 1#6G IN 1-1/4" _ U 3 SETS - 4-600MCM & 1#3/OG - 4" 6 G G G 6 ELECTRICAL RISER NOTES C0 z p 1 G 2 2 G 1 gyp. (�V O4 EXOTHERMIC CONNECTION. (TYPICAL) O 1/ C/W L ,�O _ _ _ _ \0. "JJ C/W O 1# 4/0 GROUNDING ELECTRODE CONDUCTOR (� G _ G G _ G IN 1 SCHEDULE 40 PVC CONDUIT. O MAKE CONNECTION TO METALLIC COLD WATER O EXOTHERMIC CONNECTION. ELECTRICALLY CONT- ENTRANCE PIPE BEFORE FIRST VALVE WITH Fa G ro4 4 INUOUS STEEL REINFORCING BAR IN BOTTOM OF HEAVY DUTY BRONZE GROUND CLAMP. U) � G BUILDING FOUNDATION IN DIRECT CONTACT WITH g PROVIDE 1 3 0 BONDING JUMPER AROUND 3 3 = EARTH. O FIRST VALVE.E. / ~ 10'-0" 10'-0" O 10 FT. LONG x 3/4" DIAMETER COPPER DRIVEN O GROUND ELECTRODE. O 100% RATED GEAR. Z NEW ELECTRICAL RISER DIAGRAM C0 � U SCHEDULE OF BRANCH CIRCUIT PANEL "2L1" SCHEDULE OF BRANCH CIRCUIT PANEL r2A" SCHEDULE OF BRANCH CIRCUIT PANEL "2C" Uj MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER (PROVIDE WITH FEED THRU LUGS) VOLTAGE: 208/120V, 30, 4 WIRE MAIN: 100 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE MAIN: 600 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE 0- w SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 22,000 MOUNTING: FLUSH AIC SYMM: 18,000 MOUNTING: FLUSH AIC SYMM: 18,000 I-�I A PHASE B PHASE C PHASE A PHASE B PHASE C PHASE A PHASE B PHASE C PHASE co DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION (V O00 CD KVA KVA KVA KVA KVA KVA KVA KVA KVA O rn M o RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES BIG ASS FAN 3#12 1#12 1/2" 15 1 0.9 0.9 2 15 1/2" 1#12 3#12 BIG ASS FAN LIGHTING #12 #12 1 2" 20 1 3.5 3.5 2 20 1 2" #12 #12 LIGHTING M CD DROP CORD POWER #12 #12 1 2" 20 3 0.8 0.8 4 20 1 2" #12 #12 DROP CORD POWER 3 0.9 0.9 4 LIGHTING #12 #12 1 2" 20 3 3.5 3.5 4 20 1 2" #12 #12 LIGHTING cai DROP CORD POWER #12 #12 1 2 20 5 0.8 0.8 6 20 1 2 #12 #12 DROP CORD POWER 3 5 0.9 0.9 6 3 LIGHTING #12 #12 1 2 20 5 3.5 3.5 6 20 1 2 #12 #12 LIGHTING Q L DROP CORD POWER #12 #12 1 2" 20 7 0.8 0.8 8 20 1 2" #12 #12 DROP CORD POWER BIG ASS FAN 3#12 1#12 1/2" 15 7 0.9 0.9 8 15 1/2" 1#12 3#12 BIG ASS FAN LIGHTING #12 #12 1 2" 20 7 3.5 3.5 8 20 1 2" #12 #12 LIGHTING DROP CORD POWER #12 #12 1 2 20 9 0.8 0.8 10 20 1 2 #12 #12 RECEPTACLES 9 0.9 0.9 10 LIGHTING #12 #12 1 2 20 9 1.8 0.8 10 20 1 2 #12 #12 LIGHTING �i w RECEPTACLES #12 #12 1 2" 20 11 0.8 0.8 12 20 1 2" #12 #12 DROP CORD POWER 3 11 0.9 0.9 12 3 LIGHTING #12 #12 1 2" 20 11 0.8 13.3 12 60 1" 1#10 3#6 DUPLEX VACUUM PUMP Lf'� U x DROP CORD POWER #12 #12 1 2" 20 13 0.8 0.8 14 20 1 2" #12 #12 DROP CORD POWER BIG ASS FAN 3#12 1#12 1/2" 15 13 0.9 0.9 14 15 1/2" 1#12 3#12 BIG ASS FAN EF-L1 3#3 1#8 1-1/4" 100 13 18.0 13.3 14 p z - LL DROP CORD POWER #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 DROP CORD POWER 15 0.9 0.9 16 15 18.0 13.3 16 3 DROP CORD POWER #12 #12 1 2" 20 17 0.8 0.8 18 20 1 2" #12 #12 DROP CORD POWER 3 17 0.9 0.9 18 3 3 17 18.0 18.0 18 100 1-1/4" 1#8 3#3 EF-L2 � O m N RECEPTACLES #12 #12 1 2 20 19 0.8 0.8 20 20 1 2 #12 #12 RECEPTACLES BIG ASS FAN 3#12 1#12 1 2 15 19 0.9 0.8 20 15 1 2 1#12 3#12 BIG ASS FAN EF-L3 3#3 1#8 1-1 4 100 19 18.0 18.0 20 �7 p c RECEPTACLES #12 #12 1 2" 20 21 0.8 1.2 22 20 1 2" #12 #12 DOOR POWER 21 0.9 0.8 22 21 18.0 18.0 22 3 �- l � ( o FIRE ALARM POWER #12 #12 1 2 20 23 1.0 1.8 24 20 1 2 #12 #12 AHU-3 CU-3 POWER 3 23 0.9 0.8 24 3 3 23 18.0 7.5 24 60 1" 1#10 3#6 EF-G1 W �•J Q 0 CN Cli DOOR POWER 2#12 1#12 1/2" 2 25 0.5 0.5 26 2 1/2" 1#12 2#12 DOOR POWER BIG ASS FAN 3#12 1#12 1/2" 15 25 0.8 0.8 26 15 1/2" 1#12 3#12 BIG ASS FAN EF-G2 3#6 1#10 1" 60 F-�-I 2 27 0.5 0.5 28 2 27 0.8 0.8 28 27 7.5 7.5 28 3 b-�I w ti DOOR POWER 2#12 1#12 1/2" 2 29 0.5 0.7 30 2 1/2" 1#12 2#12 DOOR POWER 3 29 0.8 0.8 30 3 3 29 7.5 18.0 30 10 1-1/4" 1#8 3#3 RAU-L2 mLu 2 31 0.5 0.7 32 2 BIG ASS FAN 3#12 1#12 1/2" 15 31 0.8 0.8 32 15 1/2" 1#12 3#12 BIG ASS FAN RAU-L1 3#3 1#8 1-1/4" 100 31 18.0 18.0 32 Q �+ m oN H DOOR POWER 2#12 1#12 1 2 2 33 0.7 0.7 34Z1 2 1#12 2#12 DOOR POWER 33 0.8 0.8 34 33 18.0 18.0 34 3 2 35 - 0.7 36 3 35 0.8 0.8 36 3 3 35 18.0 18.0 36 100 1-1/4" 1#8 3#3 RAU-L3 AHU-1/ CU-1 POWER 2#8 1#10 3 4 4 37 2.5 - 38 20 - - - SPARE SPARE - - - 20 37 - - 38 90 - - - SPARE SPARE - - - 20 37 - - 38 2 39 2.5 - 40 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - - - 20 39 - - 40 3 SPARE - - - 20 41 - - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE 7.6 6.8 7.6 KVA PER PHASE PANEL "2L1" 10.3 10.3 10.3 KVA PER PHASE 132.3 127.9 144.1 KVA PER PHASE 12.1 10.1 11.7 KVA PER PHASE PANEL "2L2" 37.2 37.2 37.2 AMPS PER PHASE 477.E 461.7 520.2 AMPS PER PHASE 11.8 12.2 12.2 KVA PER PHASE PANEL "2L5" 30.9 TOTAL KVA 404.3 TOTAL KVA 31.5 29.1 31.5 TOTAL KVA PER PHASE 262.5 242.5 262.5 TOTAL AMPS PER PHASE 92.1 TOTAL KVA SCHEDULE OF BRANCH CIRCUIT PANEL "2Br SCHEDULE OF BRANCH CIRCUIT PANEL "2D" SCHEDULE OF BRANCH CIRCUIT PANEL "2L4" MAIN: 200 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT MAIN: 225 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/120V, 30, 4 WIRE MOUNTING: FLUSH AIC SYMM: 18,000 MOUNTING: FLUSH AIC SYMM: 18,000 Q SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT A PHASE B PHASE C PHASE A PHASE B PHASE C PHASE DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION MOUNTING: FLUSH AIC SYMM: 22,000 KVA KVA KVA KVA KVA KVA � A PHASE 6 PHASE C PHASE BIG ASS FAN 3#12 1#12 1 2 15 1 0.8 0.8 2 15 1 2 1#12 3#12 BIG ASS FAN AIR COMPRESSOR 4#3 0 1#2 -1 2 00 1 44.3 4.2 2 15 1 2 1#12 3#12 REFRIGERATED AIR DRYER o DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION V KVA KVA KVA 3 0.8 0.8 4 3 44.3 4.2 4 RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES 3 5 0.8 0.8 6 3 3 5 44.3 4.2 6 3 DROP CORD POWER #12 #12 1 2 20 3 0.8 0.8 4 20 1 2 #12 #12 DROP CORD POWER BIG ASS FAN 3#12 1#12 1/2" 15 7 0.8 3.5 8 20 1 2" #12 #12 LIGHTING CNC ROUTER 3#6 1#10 1" 60 7 16.6 16.6 8 65 1" 1#10 3#6 CNC ROUTER (� J o DROP CORD POWER #12 #12 1 2" 20 5 0.8 0.8 6 20 1 2" #12 #12 DROP CORD POWER 9 0.8 3.5 10 20 1 2" #12 #12 LIGHTING 9 16.6 16.6 10 Q DROP CORD POWER #12 #12 1 2 20 7 0.8 0.8 8 20 1 2 #12 #12 DROP CORD POWER 3 11 0.8 3.5 12 20 1 2 #12 #12 LIGHTING 3 11 16.6 16.6 12 3 00 M M DROP CORD POWER #12 #12 1 2" 20 9 0.8 0.8 10 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 13 3.5 3.5 14 20 1 2" #12 #12 LIGHTING TABLE VACUUMS 3#6 1#10 1" 60 13 16.6 - 14 20 - - - SPARE _ DROP CORD POWER #12 #12 1 2" 20 11 0.8 0.8 12 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2 20 15 3.5 3.5 16 20 1 2 #12 #12 LIGHTING 15 16.6 - 16 20 - - - SPARE -Ile i LL DROP CORD POWER #12 #12 1 2" 20 13 0.8 0.8 14 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 17 3.5 3.5 18 20 1 2" #12 #12 LIGHTING 3 17 16.6 - 18 20 - - - SPARE •� 2 RECEPTACLES #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 RECEPTACLES LIGHTING #12 #12 1 2 20 19 3.5 3.5 20 20 1 2 #12 #12 LIGHTING DROP CORD POWER #12 #12 1 2 20 17 0.8 0.8 18 20 1 2 #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 21 3.5 3.5 22 20 1 2" #12 #12 LIGHTING SPARE - - - 20 21 - - 22 20 - - - SPARE a DROP CORD POWER #12 #12 1 2" 20 19 0.8 0.8 20 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 23 3.5 3.5 24 20 1 2" #12 #12 LIGHTING SPARE - - - 20 23 - - 24 20 - - - SPARE (� d o L DROP CORD POWER #12 #12 1 2 20 21 0.8 0.8 22 20 1 2 #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2 20 25 3.5 3.5 26 20 1 2 #12 #12 LIGHTING SPARE - - - 20 25 - - 26 20 - - - SPARE U DROP CORD POWER #12 #12 1 2" 20 23 0.8 0.8 24 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 27 3.5 3.5 28 20 1 2" #12 #12 LIGHTING SPARE - - - 20 27 - - 28 20 - - - SPARE M DROP CORD POWER #12 #12 1 2" 20 25 0.8 0.8 26 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2 20 29 3.5 3.5 30 20 1 2 #12 #12 LIGHTING SPARE - - - 20 29 - - 30 20 - - - SPARE DROP CORD POWER #12 #12 1 2" 20 27 0.8 0.8 28 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 31 3.5 3.5 32 20 1 2" #12 #12 LIGHTING SPARE - - - 20 31 - - 32 20 - - - SPARE m DROP CORD POWER #12 #12 1 2" 20 29 0.8 1.0 30 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2 20 33 3.5 3.5 34 20 1 2 #12 #12 LIGHTING SPARE - - - 20 33 - - 34 20 - - - SPARE U RECEPTACLES #12 #12 1 2 20 31 0.8 0.8 32 20 1 2 #12 #12 RECEPTACLES LIGHTING #12 #12 1 2" 20 35 3.5 3.5 36 20 1 2" #12 #12 LIGHTING SPARE - - - 20 35 - - 36 20 - - - SPARE RECEPTACLES #12 #12 1 2" 20 33 0.8 0.8 34 20 1 2" #12 #12 RECEPTACLES LIGHTING #12 #12 1 2" 20 37 3.5 2.6 38 20 1 2" #12 #12 LIGHTING SPARE - - - 20 37 - - 38 20 - - - SPARE RECEPTACLE #12 #12 1 2 20 35 1.0 1.0 36 20 1 2 #12 #12 RECEPTACLE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE RECEPTACLE #12 #12 1 2" 20 37 1.0 1.0 38 20 1 2" #12 #12 RECEPTACLE SPARE - - - 20 41 - - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE FLOW TAMPER POWER #12 #12 1 2" 20 39 1.2 - 40 20 - - - SPARE .033.9 33.9 KVA PER PHASE 98.3 98.3 98.3 KVA PER PHASESPARE - - - 20 41 - - 42 20 - - - SPARE �40 44.4 122.4 122.4 AMPS PER PHASE 354.9 354.9 354.9 AMPS PER PHASE •U) 11.6 10.8 10.2 KVA PER PHASE 107.8 TOTAL KVA 294.9 TOTAL KVA 96.7 90.0 85.0 AMPS PER PHASE 32.6 TOTAL KVA X w SCHEDULE OF BRANCH CIRCUIT PANEL r2L5" SCHEDULE OF BRANCH CIRCUIT PANEL "2L2". SCHEDULE OF BRANCH CIRCUIT PANEL "2G" MAIN: 225 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/12OV, 30, 4 WIRE MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE MAIN: 225 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/120V, 30, 4 WIRE SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 22,000 MOUNTING: FLUSH AIC SYMM: 18,000 MOUNTING: FLUSH AIC SYMM: 22,000 DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION A PHASE B PHASE C PHASE KVA KVA KVA KVA KVA KVA DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION KVA KVA KVA RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES AIR COMPRESSOR 4#3/0 1#2 2-1/2' 00 1 44.3 4.2 2 15 1/2" 1#12 3#12 REFRIGERATED AIR DRYER RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES RECEPTACLES #12 #12 1 2" 20 3 0.8 0.8 4 20 1 2" #12 #12 DROP CORD POWER 3 44.3 4.2 4 RECEPTACLES #12 #12 1 2 20 3 0.8 0.8 4 20 1 2 #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2" 20 5 0.8 0.8 6 20 1 2" #12 #12 DROP CORD POWER 3 5 44.3 4.2 6 3 DROP CORD POWER #12 #12 1 2" 20 5 0.8 0.8 6 20 1 2" #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2 20 7 0.8 0.8 8 20 1 2 #12 #12 DROP CORD POWER SITE LIGHTING 2#10 1#10 3/4" 0 7 1.2 1.2 8 2 3/4" 1#10 2#10 SITE LIGHTING DROP CORD POWER #12 #12 1 2" 20 7 0.8 0.8 8 20 1 2" #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2" 20 9 0.8 0.8 10 20 1 2" #12 #12 DROP CORD POWER 2 9 1.2 1.2 10 2 a--� DROP CORD POWER #12 #12 1 2" 20 9 0.8 0.8 10 20 1 2" #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2 20 11 0.8 0.8 12 20 1 2 #12 #12 RECEPTACLES SITE LIGHTING 2#10 1#10 3/4" O 11 1.2 1.2 12 2 3 4 1#10 2#10 SITE LIGHTING m DROP CORD POWER #12 #12 1 2" 20 11 0.8 0.8 12 20 1 2" #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2" 20 13 0.8 0.8 14 20 1 2" #12 #12 DROP CORD POWER 2 13 1.2 1.2 14 2 DROP CORD POWER #12 #12 1 2 20 13 0.8 0.8 14 20 1 2 #12 #12 RECEPTACLES DROP CORD POWER #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 DROP CORD POWER DUST COLLECTOR 3#6 1#8 1" 65 15 18.0 18.0 16 65 1" 1#10 3#6 TABLE VACUUMS m RECEPTACLES #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2" 20 17 0.8 0.8 18 20 1 2" #12 #12 DROP CORD POWER 17 18.0 18.0 18 m DROP CORD POWER #12 #12 1 2 20 17 0.8 0.8 18 20 1 2 #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2" 20 19 0.8 0.8 20 20 1 2" #12 #12 DROP CORD POWER 3 19 18.0 18.0 20 3 DROP CORD POWER #12 #12 1 2" 20 19 0.8 0.8 20 20 1 2" #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2 20 21 0.8 0.8 22 20 1 2 #12 #12 RECEPTACLES SPARE - - - 20 21 - - 22 20 - - - SPARE V DROP CORD POWER #12 #12 1 2" 20 21 0.8 0.8 22 20 1 2" #12 #12 DROP CORD POWER IWH 2#8 1#10 3/4" 4 23 3.3 0.8 24 20 1 2" t12 #12 RECEPTACLES SPARE - - - 20 23 - - 24 20 - - - SPARE •� DROP CORD POWER #12 #12 1 2 20 23 0.8 0.8 24 20 1 2" #12 #12 DROP CORD POWER 2 25 3.3 0.8 26 20 1 2 #12 RECEPTACLES SPARE - - - 20 25 - - 26 20 - - - SPARE > DROP CORD POWER #12 #12 1 2" 20 25 0.8 0.8 26 20 1 2" #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2" 20 27 0.8 0.9 28 20 1 2" #12 DRINKING FOUNTAIN SPARE - - - 20 27 - - 28 20 - - - SPARE DROP CORD POWER #12 #12 1 2 20 27 0.8 0.8 28 20 1 2 #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2" 20 29 0.8 0.8 30 20 1 2" #12 RECEPTACLES SPARE - - - 20 29 - - 30 20 - - - SPARE z C DROP CORD POWER #12 #12 1 2" 20 29 0.8 1.0 30 20 1/2" #12 #12 RECEPTACLES RECEPTACLES #12 #12 1 2" 20 31 0.8 0.8 32 20 1 2"RECEPTACLES #12 #12 1 2 20 31 1.0 0.8 32 20 1 2 #12 #12 RECEPTACLES JIB CRANE #12 #12 1 2" 20 33 1.2 0.8 34 20 1 2" #12 RECEPTACLES SPARE - - - 20 33 - - 34 20 - - - SPARE o RECEPTACLES #12 #12 1 2" 20 33 0.8 1.0 34 20 1 2" #12 #12 GARBAGE DISPOSAL JIB CRANE #12 #12 1 2 20 35 1.2 3.3 36 4 3 4 1#10 2#8 DIP POOL SPARE - - - 20 35 - - 36 20 - - - SPARE RECEPTACLES #12 #12 1 2" 20 35 0.8 0.8 36 20 1 2" #12 #12 RECEPTACLES SUMP PUMP #12 #12 1 2" 20 37 1.2 3.3 38 2 SPARE - - - 20 37 - - 38 20 - - - SPARE RECEPTACLE #12 #12 1 2" 20 37 1.0 1.0 38 20 1 2" #12 #12 RECEPTACLE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE DOOR POWER #12 #12 1 2" 20 39 1.2 1.2 40 20 142 #12 #12 DOOR POWER SPARE - - - 20 41 - - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE DOOR POWER #12 #12 1 2 20 41 1.2 1.2 42 20 1 2 #12 #12 DOOR POWER 15.4 10.1 15.0 KVA PER PHASE 89.3 86.9 86.9 KVA PER PHASE 11.8 12.2 12.2 KVA PER PHASE 128.3 84.2 125.0 AMPS PER PHASE 322.4 313.7 313.7 AMPS PER PHASE 98.3 101.7 101.7 AMPS PER PHASE 40.5 TOTAL KVA 263.1 TOTAL KVA 36.2 TOTAL KVA SCHEDULE OF BRANCH CIRCUIT PANEL "2E" SCHEDULE OF BRANCH CIRCUIT PANEL "2L3". SCHEDULE OF DRY-TYPE TRANSFORMERS MAIN: 225 AMP / 3 POLE MAIN CIRCUIT BREAKER (PROVIDE WITH FEED THRU LUGS) VOLTAGE: 208/12OV, 30, 4 WIRE VOLTAGE SECONDARY FEEDER MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT MARK KVA PRIMARY SECONDARY MOUNTING MARK BREAKER FEEDER NOTES SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 22,000 T1A 75 480 VOLT 208 120 VOLT - T1D-1L O 4#4/0 & 112G - MOUNTING: FLUSH AIC SYMM: 18,000 DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION 30,3W 30,4W IN 2-1/2' DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION KVA KVA KVA - - - - - - - - - KVA KVA KVA RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES LIFT STATION 3#12 1#12 1 2 20 1 4.4 4.4 2 15 1 2 1#12 3#12 LIFT STATION DROP CORD POWER #12 #12 1 2 20 3 0.8 0.8 4 20 1 2 #12 #12 DROP CORD POWER 3 4.4 4.4 4 DROP CORD POWER #12 #12 1 2" 20 5 0.8 0.8 6 20 1 2" #12 #12 DROP CORD POWER NOTE: 3 5 4.4 4.4 6 3 DROP CORD POWER #12 #12 1 2" 20 7 0.8 0.8 8 20 1 2" #12 #12 RECEPTACLES O PANEL MAIN BREAKER IS TRANSFORMER SECONDARY BREAKER. CNC ROUTER 3#6 1#10 1" 60 7 16.6 16.6 8 65 1" 1#10 3#6 CNC ROUTER RECEPTACLES #12 #12 1 2" 20 9 0.8 0.8 10 20 1 2" #12 #12 DROP CORD POWER 9 16.6 16.6 10 DROP CORD POWER #12 #12 1 2" 20 11 0.8 0.8 12 20 1 2" #12 #12 DROP CORD POWER 3 11 16.6 16.6 12 3 DROP CORD POWER #12 #12 1 2 20 13 0.8 0.8 14 20 1 2 #12 #12 DROP CORD POWER TABLE VACUUMS 3#6 1#10 1" 60 13 16.6 16.6 14 60 1" 1#10 3#6 TABLE VACUUMS DROP CORD POWER #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 DROP CORD POWER 15 16.6 16.6 16 DROP CORD POWER #12 #12 1 2 20 17 0.8 0.8 18 20 1 2 #12 #12 DROP CORD POWER 3 17 16.6 16.6 18 3 DROP CORD POWER #12 #12 1 2" 20 19 0.8 0.8 20 20 1 2" #12 #12 RECEPTACLES DUST COLLECTOR 3#6 1#10 1" 65 19 18.0 - 20 20 - - - SPARE RECEPTACLES #12 #12 1 2 20 21 0.8 2.5 22 4 3 4 1#10 2#8 EWH 21 18.0 - 22 20 - - - SPARE RECEPTACLES #12 #12 1 2" 20 23 0.8 2.5 24 2 V► 3 23 18.0 - 24 20 - - - SPARE RECEPTACLES #12 #12 1 2" 20 25 0.8 0.8 26 20 1 2" #12 #12 RECEPTACLES SPARE - - - 20 25 - - 26 20 - - - SPARE RECEPTACLES #12 #12 1 2 20 27 0.8 0.8 28 20 1 2 #12 #12 RECEPTACLES ai SPARE - - - 20 27 - - 28 20 - - - SPARE RECEPTACLES #12 #12 1 2" 20 29 0.8 0.8 30 20 1 2" #12 #12 RECEPTACLES A SPARE - - - 20 29 - - 30 20 - - - SPARE RECEPTACLES #12 #12 1 2 20 31 0.8 0.8 32 20 1 2 #12 #12 RECEPTACLES z p4 SPARE - - - 20 31 - - 32 20 - - - SPARE RECEPTACLE #12 #12 1 2" 20 33 1.0 1.0 34 20 1 2" #12 #12 RECEPTACLE SPARE - - - 20 33 - - 34 20 - - - SPARE SPARE - - - 20 35 - 1.0 36 20 1 2 #12 #12 RECEPTACLE i••� SPARE - - - 20 35 - - 36 20 - - - SPARE SPARE - - - 20 37 - 1.0 38 20 1 2" #12 #12 RECEPTACLE Ali SPARE - - - 20 37 - - 38 20 - - - SPARE RESIN SYSTEM 2#10 1#10 3/4" 3 39 2.4 - 40 20 - - - SPARE p SPARE - - - 20 39 - - 40 20 - - - SPARE 2 41 2.4 - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE 10.6 14.1 13.1 KVA PER PHASE PANEL "2L3" 93.2 93.2 93.2 KVA PER PHASE 11.6 10.8 10.2 KVA PER PHASE PANEL "2L4" 336.5 336.5 336.5 AMPS PER PHASE 22.2 24.9 23.3 TOTAL KVA PER PHASE 279.6 TOTAL KVA 185.0 207.5 194.2 TOTAL AMPS PER PHASE 70.4 TOTAL KVA o Lo O N ISSUED FOR PERMIT ONLY 05-07-21 o Digitally signed by Bradly L NOT FOR PRICING ORCONSTRUCITON N Cfl L r � � N Brown P.E. KAMM CONSULTING PROJECT#: 2020-0562 E Bradly L DN: cn=Bradly L Brown P.E., PROJECT MANAGER: JOHNMAYR z 1408 Orange Avenue o=Kamm Consulting Inc., ou=FL# ffkA MM Fort Pierce,Florida34950 o 0 0792 58232 Phone 9kamm onsu m a_ a_ jmayr@kammconsulting.com Brown One Certification of Authorization#8189 email=jmayr@kammconsulting.c P . E � PRINCIPAL 05-07-21 om, e=US BradlyLBrown Florida License#58232 date Date: 2021.05.07 16:29:10 -04'00' signed