Loading...
HomeMy WebLinkAbout2020-0562E6-1-E6-1 SCHEDULE OF BRANCH CIRCUIT PANEL 772F" N ME: L mo3 v MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE `°" m 0 76 SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 18,000 m� A PHASE B PHASE C PHASE 3 ''L DESCRIPTION WIRE GND. COND. TRIP CKT. KVA KVA KVA CKT. TRIP COND. GND. WIRE DESCRIPTION g c SPARE - - - 20 1 - - 2 20 - - - SPARE SPARE - - - 20 3 - - 4 20 - - - SPARE _ `" LU SPARE - - - 20 5 - - 6 20 - - - SPARE U)y p m a SPARE - - - 20 7 - - 8 20 - - - SPARE N m m SPARE - - - 20 9 - - 10 20 - - - SPARE _ o z SPARE - - - 20 11 - - 12 20 - - - SPARE a' - O LL s? � SPARE - - - 20 13 - - 14 20 - - - SPARE 2i T L s t U o SPARE - - - 20 15 - - 16 20 - - - SPARE `� SPARE - - - 20 17 - - 18 20 - - - SPARE c 0 a s s SPARE - - - 20 19 - - 20 20 - - - SPARE SPARE - - - 20 21 - - 22 20 - - - SPARE L Q N M V CO I� SPARE - - - 20 23 - - 24 20 - - - SPARE Q m m _ SPARE - - - 20 25 - - 26 20 - - - SPARE z O SPARE - - - 20 27 - - 28 20 - - - SPARE O SPARE - - - 20 29 - - 30 20 - - - SPARE SPARE - - - 20 31 - - 32 20 - - - SPARE SPARE - - - 20 33 - - 341 20 - - - ISPARE U SPARE - - - 20 35 - - 36 20 - - - SPARE SPARE - - - 20 37 - - 38 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE 98.3 98.3 98.3 KVA PER PHASE U) 354.9 354.9 354.9 AMPS PER PHASE 294.9 TOTAL KVA z O U SCHEDULE OF DISTRIBUTION PANEL 77MDP1" o 101 Lj- U) MAIN: 1200 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 O DESIGNATION DESCRIPTION CIRCUIT BREAKER FEEDER A PHASE B PHASE C PHASE NOTES FRAME TRIP POLES KVA KVA KVA z MDP1-1 PANEL 2A - 100 3 4 & 1#8G - 1-1 4 10.3 10.3 10.3 MDP1-2 PANEL 2B - 200 3 4J64U & 1#2G - 2-1 40.0 33.9 33.9 MDP1-3 PANEL 2C - 600 3 2 SEIS - - 6 - 132.3 127.9 144.1 MDP1-4 DCF-D1 - 60 3 3 6 & 1#1OG IN 1-1/4" 16.0 16.0 16.0 w MDP1-5 PANELS "213 & 214" VIA XFMR - 110 3 4- 4 0 & 1 2G IN 2-1 2" 10.6 14.1 13.1 U) MDP1-6 RALI-G1 - 100 3 3 3 & 1#8G IN 1-1/4- 18.0 18.0 18.0 MDP1-7 DCF-H1 - 70 3 3 4 & 1 8G IN 1-1/4. 18.8 18.8 18.8 MDP1-8 DCF-D1 - 70 3 3 4 & 1 8G IN 1-1/4- 18.8 18.8 18.8 ~ `J MDP1-9 GEL BOOTH - 60 3 3#6 & 1#10G IN 1-1/4" 16.0 16.0 16.0 MDPl-10 GEL BOOTH - 60 3 3#6 & 1 10G IN 1-1 4 16.0 16.0 16.0 MDPl-11 SPARE - - - - - - I - MDP1-12 TVSS - 30 1 1 10 & 1 10G - 3 4 2.9 - - w ^ MDPl-13 PANEL 2F - 400 3 4-500MCM & 1 3G - 4 - - - Q w MDPl-14 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1 0.9 0.9 0.9 o MDPl-15 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1 0.9 0.9 0.9 MDPl-16 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1 0.9 0.9 0.9 MDPl-17 SPARE - - - - - - - N o00 MDPl-18 SPARE - - - - - - - C M c9 't o LO MDPl-19 - - - - - - - - CV co MDPl-20 - - - - - - - - rr l� 299.7 289.8 323.9 KVA PER PHASE W M 1081.9 1046.2 1169.3 AMPS PER PHASE Ln Q x 913.4 ITOTAL KVA C [� U m Z LL M-�-I 00 m SCHEDULE OF DISTRIBUTION PANEL "MDP2" w Q o 0 MAIN: 1200 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE Z u1 ti SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 w cn CIRCUIT BREAKER A PHASE B PHASE C PHASE Q �j m oN H DESIGNATION DESCRIPTION FRAME TRIP POLES FEEDER KVA KVA KVA NOTES MDP2-1 AIR COMPRESSOR - 250 3 3-250MCM & 1 4G - 3 34.6 34.6 34.6 MDP2-2 AIR COMPRESSOR - 250 3 3-250MCM & 1 4G - 3 34.6 34.6 34.6 MDP2-3 AIR DRYER - 30 3 3- 10 & 1 10G - 3 4 8.3 8.3 8.3 MDP2-4 PANELS 21-1,21-2,&21-5 VIA XFM - 110 3 4-#4 0 & 1#2G IN 2-1 2 31.5 29.1 31.5 MDP2-5 HOIST - 90 3 3 3 & 1 8G - 1-1 4 15.0 15.0 15.0 MDP2-6 HOIST - 90 3 3 3 & 1 8G - 1-1/4- 15.0 15.0 15.0 MDP2-7 GEL BOOTH - 60 3 3#6 & 1 10G IN 1-1 4 16.0 16.0 16.0 MDP2-8 BRIDGE CRANE - 60 3 3#6 & 1 10G IN 1-1/4" 16.0 16.0 16.0 MDP2-9 PANEL 2D - 400 3 4-500MCM & 1 3G - 4 98.3 98.3 98.3 MDP2-10 GRIND BOOTH - 60 3 3#6 & 1 10G IN 1-1/4" 16.0 16.0 16.0 MDP2-11 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1" 0.9 0.9 0.9 MDP2-12 TVSS - 30 1 1 10 & 1 10G - 3 4 2.9 - - MDP2-13 BIG ASS FAN - 20 3 3#12 & 1#12G IN 1 0.9 0.9 0.9 MDP2-14 - - - - - - - - MDP2-15 - - - - - - - - MDP2-16 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1 0.9 0.9 0.9 MDP2-17 - - - - - - - - MDP2-18 - - I - - - - - - Q MDP2-19 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1 0.9 0.9 0.9 Z3 > MDP2-20 - - - - - - - - Q MDP2-21 - - - - - - - 293.6 288.3 290.7 KVA PER PHASE L! 1059.9 1040.8 1049.5 1 AMPS PER PHASE J 872.E ITOTAL KVA O co M � � M J U i U- N � L (6 a � U oL M L.L C N U O Ca Q X w Q� U) A C rL V m C m -> � m U U U E > C/7 Z U Lf U � O d a A A w iv x E m a Z z a 0 0 Lo Digitally signed by Bradly L ISSUED FOR PERMIT ONLY 05-07-21 CD N r L Brown P.E. NOT FOR PRICING OR N Cfl a .. L � 0) DN: cn=Bradly L Brown P.E., KAMMCONSULTING PROJECT#: 2020-0562 0 E PROJECT MANAGER: JOHN MAYR Z Qj o=Kamm Consulting Inc., Z M M 1408 Orange Avenue a) m 0 "o w n ou=FL# 58232, Fort Pierce,Florida 34950 r o Phone 954.448.0792 � - - jmayr@kammconsulting.com U) a_ E e m a i l=j m a y r@ ka m m e o n s u l t onsu n9 Certification of Authorization#8189 ing.com, c=US PRINCIPAL 05-07-21 POEO Date: 2021 .05.07 1 6:28:43 Bradly L Brown Florida License#58232 date -04'00' signed