Loading...
HomeMy WebLinkAbout002-220050_GN-1 BUILDING AREA SUMMARY r ABBREVIATIONS GENERAL NOTES N N DRAWING INDEX INTERIOR BUILDING AREA CALCULATIONS. N t 9 16 ri FIRST REVISION LATEST g LL p o SPACE DESCRIPTION AREA SHEET# SHEETTITLE ISSUED NUMBER REVISION s b =n AB ANCHOR BOLT MATL MATERIAL Y < 1. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. ANY DIMENSION NOT GIVEN OR MISLABELED SHALL BE F- A/C AIR CONDITIONING MECH MECHANICAL EXISTING GROUND FLOOR AREAS (PHASE 1) ARCHITECTURAL CONFIRMED WITH THE ARCHITECT PRIOR TO CONSTRUCTION. o a ~ AFF ABOVE FINISH FLOOR MEMB MEMBRANE 1 � _ m w EXISTING GROUND FLOOR CONDITIONED SPACE AREA TOTAL 4,590 S.F. CV-1 COVER SHEET, CONSULTANT INFORMATION& LOCATION MAP 05.07.2021 1 05.25.2021 y Z ALUM ALUMINUM MTL MEAN TIDE LEVEL 2. ANY DISCREPANCIES WITH THE DRAWINGS DIMENSIONS OR OTHERWISE SHALL BE BROUGHTTO THE - s o APPROX APPROXIMATELY MFC METAL FURRING CHANNEL ARCHITECT'S ATTENTION PRIOR TO PURCHASING OF MATERIALS, PROJECT COMPONENTS AND EXISTING GROUND FLOOR UNCONDITIONED SPACE AREATOTAL 106,250 S.F. GN-1 DRAWING INDEX, ABBREVIATIONS, GENERAL NOTES & BUILDING CODE ANALISYS 05.07.2021 1 05.25.2021 ° s L � m COMMENCEMENT OF CONSTRUCTION. EXISTING GROUND FLOOR EXTERIOR COVERED WORK AREA TOTAL 20,910 S.F. ARCH ARCHITECTURAL ARCHITECT MFR MANUFACTURER GN-2 2017 FLORIDA BUILDING CODE ANALISYS 05.07.2021 L o J - BD BOARD MIN MINIMUM a_ Q o 3. ALL WORK TO BE PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE CURRENT BUILDING CODE GN-3 2017 FLORIDA BUILDING CODE ANALISYS 05.07.2021 BLDG BUILDING MIR MIRROR AS STATED ON THE BUILDING CODE SUMMARY IN THESE DOCUMENTS, AS WELL AS ALL CITY ORDINANCES, BILK BLOCK MISC MISCELLANEOUS RULES AND REGULATIONS. ALL WORK SHALL CONFORM TO FLORIDA STATE STATUTES. EXISTING GROUND FLOOR FOOTPRINT(PHASE 1) -GROSS AREA TOTAL 131,750 S.F. GNP 2017 FLORIDA BUILDING CODE ANALISYS 05.07.2021 N .Q O BOT/BOTT BOTTOM MO MASONRY OPENING BRG BEARING MR MOISTURE RESISTANT 4. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE CONTRACT DOCUMENTS, AND CONTRACT GN-5 2017 FLORIDA BUILDING CODE ANALISYS 05.07.2021 N `� r N "' "' ° ~ °' BTWN BETWEEN MT METAL THRESHOLD SUPPLEMENTS RELATIVE TO THE SCOPE OF THE WORK RELATING TO THIS PROJECT. GROUND FLOOR ADDITION AREA(PHASE 11) CIVIL Z O CAB CABINET NAT NATURAL 5. GENERAL CONTRACTOR SHALL CALL 1-800-432-4770 (CALL BEFORE YOU DIG), TWO FULL BUSINESS DAYS ADDITION GROUND FLOOR -UNCONDITIONED MANUFACTURING SPACE AREA TOTAL 106,250 S.F. C1 COVER SHEET, LOCATION MAP & DRAWING INDEX 05.07.2021 O CLG/CEIL CEILING NIC NOT IN CONTRACT BEFORE DIGGING. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DISRUPTION TO ANY UTILITY SERVICES CEM CEMENT # NUMBER DAMAGED. ADDITION GROUND FLOOR CONDITIONED ELECTRICAL EQUIPMENT ROOM 376 S.F. C2 MASTER SITE PLAN 05.07.2021 U P 10�� CL CLOSET NOM NOMINAL C3 PAVING, GRADING &DRAINAGE, 0�UTILITY PLAN 05.07.2021 �Q ma's' 6. THE CONTRACTOR SHALL TAKE APPROPRIATE ACTION TO PROVIDE THE NECESSARY PROTECTION OF THE O v� CLR CLEAR NTS NOT TO SCALE � O c� COL COLUMN CIA OVERALL/OUTSIDE AIR GENERAL PUBLIC AND PREVENT ACCESS TO THE PROJECT SITE. THE CONTRACTOR IS TO SECURE THE SITE ADDITION GROUND FLOOR FOOTPRINT GROSS AREA TOTAL 106,626 S.F. C4 DETAILS 05.07.2021 o WITH ADEQUATE SAFETY MEASURES TO PREVENT ACCESS TO THE PUBLIC OF AREAS UNDER U) U. Q * p CONC CONCRETE OC ON CENTER EXISTING GROUND FLOOR FOOTPRINT GROSS AREA TOTAL 131,750 S.F. STRUCTURAL CONSTRUCTION. z O r I � ,�, W CONTT CONSTRUCTION OPNG OPENING ?i Q a CONT CONTINUOUS OPP OPPOSITE 7. IT IS RECOGNIZED THAT THE CONTRACT DOCUMENTS DO NOT COVER SOME CONDITIONS OR MODIFICATIONS S 1.01 FOUNDATION PLAN 05.07.2021 Q WHICH MAY BE REQUIRED AND WHICH MAY NOT ACCURATELY REFLECT THE EXISTING CONDITIONS. IT IS TOTAL AREA UNDER ROOF 238,376 S.F. C) CONTR CONTRACTOR ORIG ORIGINAL 5-1.02 PARTIAL WAREHOUSE FOUNDATION PLAN 05.07.2021 - - . FZ CT CERAMIC TILE PART PARTITION HOWEVER, INTENDED THAT THE CONDITIONS NOT DETAILED OR NOT SHOWN ACCURATELY SHALL BE DEVELOPED THOUGH THE TRADE CONTRACTORS VIA SHOP DRAWINGS, REPORTS OR SPECIFICATIONS TO S-2.01 NOTES & SCHEDULES 05.07.2021 CTR CENTER PL PLATE THE SAME LEVEL OR AESTHETICS AND IN COMPLIANCE WITH THE PERFORMANCE CRITERIA AS INDICATED O DEG (°) DEGREE PLAS PLASTER FOR DETAILED AREAS AND STIPULATED IN THESE DOCUMENTS. THE CONTRACTOR, IN THEIR PREPARATION BUILDING OCCUPANCY ANALYSIS S-3.01 SECTIONS& DETAILS 05.07.2021 DEPT DEPARTMENT PLWD PLYWOOD OF THEIR BID, IS TO VISITTHE SITE AND DETERMINE THE EXISTING CONDITIONS FORTHEMSELVES.THE S-4.01 SECTIONS& DETAILS 05.07.2021 Digitally signed by Brent DTL DETAIL PNL PANEL TRADE CONTRACTORS BY ACCEPTING A CONTRACT FOR THE WORK ACKNOWLEDGES THIS AND AGREES ~ Brent A.Wood DF DRINKING FOUNTAIN PNT/PTD PAINT/ PAINTED THAT THE OWNE R AND ARCH ITECT SHAL L HAVE THE FINAL APPROVAL. SECTION 1004 - OCCUPANT LOAD: S-5.01 SECTIONS&DETAILS 05.07.2021 Cw DN:cn=Brent A.Wood, o=Brent A.Wood DIA DIAMETER POL POLISHED 8. ANY SUBSTITUTIONS, REVISIONS, OR ADDITIONS PROPOSED BY THE CONTRACTOR OR THEIR TABLE 1004.1.2 MAXIMUM FLOORAREA ALLOWANCES PER OCCUPANT S-6.01 LOADING DOCK FOUNDATION PLAN 05.07.2021 J Architecture,LLC., DIM DIMENSION PREFAB PREFABRICATED SUB CONTRACTORS SHALL BE SUBMITTED TO OWNER FOR APPROVAL PRIOR TO IMPLEMENTATION. THE A. ou=Architecture, FUNCTION OF SPACE AREA PER USE NO. OF OCCUPANTS S-6.02 LOADING DOCK SECTIONS &DETAILS 05.07.2021 Q email=erick@bawoodarc DN DOWN PROJ PROJECT ARCHITECT IS NOT RESPONSIBLE FOR THE TECHNIQUES, MEANS, AND METHODS EMPLOYED BY THE h.com,c=US DR DOOR PSF POUNDS PER SQUARE FOOT CONTRACTOR OR THEIR SUBCONTRACTORS FOR THE FABRICATION OR INSTALLATION OF ANY SPECIFIED Date:2021.05.27 GROUND FLOOR ADDITION AREA(PHASE 11): (OCCUPANT LOAD FACTOR ARCHITECTURAL WoodDWG DRAWING PSI POUNDS PER SQUARE INCH ITEM OR MATERIAL, IT IS THE RESPONSIBILITY OF THE PARTY SUBMITTING THE SUBSTITUTION REQUESTTO 17:18:09-04'00' RESEARCH AND QUALIFY THAT PERFORMANCE AND CONSTRUCTION SPECIFICATIONS MEETTHOSE OFTHE EX 1.00 EXISTING ARCHITECTURAL SITE PLAN 05.07.2021 � U EA EACH PT PRESSURE TREATED MANUFACTURING AREAS (1 Occupant per 200 sq.ft.) 106,250 sq.ft. 532 OCCUPANTS ORIGINALLY SPECIFIED ITEM OR MATERIAL PRIORTO SUBMISSION OF SUBSTITUTIONS TO THE DESIGNER. EX-1.11 EXISTING BUILDING FLOOR PLAN 05.07.2021 m EL/ELEV ELEVATION PVMT PAVEMENT ELEC ELECTRIC/ ELECTRICAL QTY QUANTITY 9. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND REPORT ANY CONDITIONS WHICH ARE IN MECHANICAL, EQUIPMENT AREAS (1 Occupant per 300 sq.ft.) 376 sq. ft. 2 OCCUPANTS EX-1.21 EXISTING BUILDING ROOF PLAN 05.07.2021 (J] ^ EQ EQUAL REF REFRIGERATOR CONFLICT WITH THE DRAWINGS AND SPECIFICATIONS TO ARCHITECT IMMEDIATELY. DO NOT PROCEED WITH EQUIV EQUIVALENT REQD REQUIRED CONSTRUCTION UNTIL ALL DISCREPANCIES ARE RESOLVED. ALL CONSTRUCTION SHALL CONFORM TO THE EX-2.01 EXISTING BUILDING ELEVATIONS 05.07.2021 F__ EQUIP EQUIPMENT REINF REINFORCED / REINFORCING REQUIREMENTS OF ALL GOVERNING FEDERAL, STATE, AND LOCAL BUILDING CODES. GROSS PHASE II AREA/OCCUPANT LOAD 106,626 sq.ft. 534 OCCUPANTS EX-3.01 EXISTING BUILDING SECTION 05.07.2021 :E O EW EACH WAY RET RETURN Or- O 10. DIMENSIONS INDICATED ON THE DIMENSION PLAN ARE TO THE FACE OF STUD OR CONCRETE SUBSTRATE. D-1.11 DEMOLITION FLOOR PLAN 05.07.2021 w co I EXH EXHAUST REV REVERSE/ REVISION 100 EXIST EXISTING RGD RIGID 11. GENERAL CONTRACTOR SHALL NOTIFY THE ELECTRICAL CONTRACTOR AND/OR OWNER IF CONFLICTS EXISTING FACILITY GROUND FLOOR(PHASE 1) A 1.00 ARCHITECTURAL SITE PLAN 05.07.2021 1 05.25.2021 a- J � EXT EXTERIOR RM ROOM OCCUR BETWEEN LIGHTING AND OTHER TRADES OR BUILDING STRUCTURE DO NOT PROCEED WITH MANUFACTURING AREAS 1 Occupant per 200 s ft. 106 250 s ft. LS 1.10 E AF TY L & O S 05.07.2021 INSTALLATION IN THAT AREA UNTIL CONFLICT HAS BEEN RESOLVED TO THE SATISFACTION OF THE OWNER { p p q. ) q• 532 OCCUPANTS 1 � w mDa N FD FLOOR DRAIN RO ROUGH OPENING AND CONTRACTOR. ~ FIN FINISH SCHED SCHEDULE OUTDOOR COVERED MANUFACTURING AREAS (1 Occupant per 200 sq.ft.) 20,910 sq. ft. 105 OCCUPANTS LS 1.11 ENLARGED LIFE SAFETY PLANS 05.07.2021 1 05.25.2021 0 � z FIX FIXTURE SD SOAP DISPENSER 12. NOTIFY THE OWNER IMMEDIATELY IF THE REMOVAL OR INSTALLATION OF LIGHTING, PLUMBING, LS-1.12 ENLARGED LIFE SAFETY PLANS 05.07.2021 1 05.25.2021 CN --i o u- a FL FLOOR SEP SEPARATE MECHANICAL, ELECTRICAL SYSTEMS OR COMPONENTS WILL ADVERSELY AFFECT THE OPERATION OF BUSINESS AREAS (1 Occupant per 100 sq.ft.) 2,240 sq.ft. 23 OCCUPANTS � � O m N A-1.10 OVERALL FLOOR PLAN 05.07.2021 _ _ O FLUOR FLUORESCENT SECT SECTION EXISTING SITE ELECTRICAL OR MEP SYSTEMS OUTSIDE THE SCOPE OF WORK. ACCESSORY STORAGE AREAS, MECHANICAL, EQUIPMENT 644 sq. ft. 3 OCCUPANTS 1 FTG FOOTING SHLF SHELF ROOMS WAREHOUSE AREAS (1 Occupant per 300 sq. ft.) A 1.11 PARTIAL FLOOR PLANS 05.07.2021 1 05.25.2021 w Q O N 13. CONTRACTOR TO COORDINATE AND SUPPLY, LOCATION, & REMOVAL OF DUMPSTERS FOR DEMOLITION& ,,/ ni FURR FURRING SHT SHEET A 1.12 PARTIAL DIMENSION FLOOR PLANS 05.07.2021 O °' isi ~ CONSTRUCTION. EXISTING BUILDING OCCUPANT LOAD (PHASE 1): 663 OCCUPANTS w GA GAGE/GAUGE SIM SIMILAR MM GALV GALVANIZED SPEC SPECIFICATION 14. FINISHES, EQUIPMENT, HARDWARE, FURNISHINGS, APPLIANCES AND LIGHTING NOT SPECIFIED ARE TO BE A-1.13 OVERALL REFLECTED CEILING PLAN 05.07.2021 Q a) GL GLASS/GLAZING SPKR SPEAKER APPROVED BY OWNER PRIOR TO PURCHASING MATERIALS. CONTRACTOR SHALL SUBMIT SAMPLES AND A-1.21 ROOF PLAN 05.07.2021 GR GRADE SQ SQUARE MANUFACTURER'S PRODUCT INFORMATION TO OWNER FOR APPROVAL. TOTAL BUILDING OCCUPANT LOAD (BOTH FLOORS COMBINED) 1,197 OCCUPANTS A-2.01 BUILDING ELEVATIONS 05.07.2021 - - GYP GYPSUM STD STANDARD 15. BUILDING ADDRESS NUMBERS SHALL BE PLACED ON IN A VISIBLE LOCATION ON THE PRIMARY FACADE, HB HOSE BIBB STL STEEL LETTERS SHALL BE A MINIMUM OF 6" IN HEIGHTAND SHALL CONTRAST WITH THE WALL FINISH WHERE THEY A 2.02 BUILDING ELEVATIONS 05.07.2021 HCP HANDICAP STOR STORAGE ARE AFFIXED. PLUMBING CODE ANALYSIS A-3.01 BUILDING SECTIONS 05.07.2021 HDWR HARDWARE SUB SUBSTITUTE / SUBSTRATE HDWD HARDWOOD SURF SURFACE 16. ALL CONSTRUCTION, DEMOLITION AND RENOVATION SHALL COMPLY WITH REQUIREMENTS OF NFPA 241. A-3.02 BUILDING SECTIONS 05.07.2021 STANDARDS FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS, 2013 OCCUPANT LOAD: HGT HEIGHT SUSP SUSPEND/ SUSPENDED EDITION. EXISTING BUILDING OCCUPANT LOAD (PHASE 1)=663 PEOPLE 50%WOMEN= 599 OCCUPANTS A-5.01 WALL TYPES 05.07.2021 HM HOLLOW METAL SYS SYSTEM NEW ADDITION OCCUPANT LOAD (PHASE 11) =534 PEOPLE 50% MEN= 598 OCCUPANTS A-5.02 UL RATED ASSEMBLY DETAILS 05.07.2021 FIR HOUR T&G TONGUE &GROOVE 17. TRASH AND CONSTRUCTION DEBRIS SHALL BE COLLECTED AND PLACED IN AN ON-SITE CONSTRUCTION COMBINED OCCUPANT LOAD (BOTH PHASES)= 1,197 PEOPLE HVAC HEATING/VENTILATING TEL TELEPHONE DUMPSTER AT THE END OF EACH WORK DAY, A-5.03 UL RATED ASSEMBLY DETAILS 05.07.2021 HW HOT WATER THK THICK/THICKNESS A-6.01 DOOR SCHEDULE, HARDWARE SCHEDULE / NOTES&DOOR TYPES 05.07.2021 IN INCH TPH TOILET PAPER HOLDER 18. A KNOX-BOX SHALL BE MOUNTED TO EXTERIOR WALL ADJACENT TO FRONT ENTRY DOORS -COORDINATE - - TYPE AND FINISH WITH OWNER AND ARCHITECT PRIOR TO PURCHASE AND INSTALLATION. COORDINATE FBC 2020, SECTION 403, TABLE 403.1: ELECTRICAL Q INCAND INCANDESCENT TRANS TRANSFORMER MOUNTING WITH MANUFACTURER SPECIFICATIONS. INCL INCLUDE TYP TYPICAL MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES PLUMBING FACILITIES _ N INFO INFORMATION UGND UNDERGROUND NUMBER 4, CLASSIFICATION - FACTORY & INDUSTRIAL, F-1 E0.1 ELECTRICAL NOTES 05.07.2021 O 1 SITE PHOTOMETRICPLAN 05.07.2021 o INSUL INSULATE / INSULATION UL UNDERWRITERS LAB. E1. }, J INT INTERIOR VERT VERTICAL WATER CLOSETS LAVATORIES E1.2 SITE POWER PLAN 05.07.2021 m KIT KITCHEN W/ W1TM DIVISION 1 - GENERAL REQUIREMENTS OCCUPANCY BATHTUBS/ DRINKING SERVICE O TYPE MALE FEMALE MALE FEMALE SHOWERS FOUNTAIN SINK E2.1 LIGHTING PLAN 05.07.2021 m � LAM LAMINATED WC WATER CLOSET LAV LAVATORY WH WATER HEATER 1 per 100 1 per 100 1 per 100 1 per 100 E2.1.1 LIGHTING PLAN 05.07.2021 �j LL SEE SECTION 'L n ai LB/LBS POUND/ POUNDS WM WIRE MESH OCCUPANCY REQUIRED: 6 6 6 6 411 1 per 400 1 E2.3 PHOTOMETRIC PLAN 05.07.2021 N a LIN LINEAR W/O WITHOUT 1.01 ARCHITECT'S STATUS TYPE: "F-1" > O E2.3.1 PHOTOMETRIC PLAN 05.07.2021 LL LIVE LOAD WP WATERPROOF (FACTORY) LT LIGHT WS WEATHER STRIPPING THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR AND WILL NOT HAVE CONTROL OR CHARGE OF PROVIDED 11 6 6 12 2 3 1 E2.4 EMERGENCY PHOTOMETRIC PLAN 05.07.2021 .92 U `o LL LVR LOUVER WWF WELDED WIRE FABRIC CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEEDURES, OR FORTHE SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR IS SOLELY E2.4.1 EMERGENCY PHOTOMETRIC PLAN 05.07.2021 m RESPONSIBLE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, AND SHALL U HAVE CONTROL OR CHARGE OVER THE ACTS OF THEIR SUBCONTRACTORS AND ANY OF THE IRAGENTS OR E3.1 POWER PLAN 05.07.2021 SYMBOLS LEGEND EMPLOYEES RELATED TO THE WORK. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR PERFORMING ANY E3.1.1 POWER PLAN 05.07.2021 OF THE WORK. O E5.1 RISER DIAGRAM 05.07.2021 1.02. CODES, E6.1 PANEL SCHEDULES 05.07.2021 A. ALL CODES HAVING JURISDICTION SHALL BE OBSERVED STRICTLY IN THE CONSTRUCTION OF THE MECHANICAL NORTH ARROW PARTITION TYPE TAG PROJECT, INCLUDING ALL APPLICABLE STATE, CITY AND COUNTY BUILDING, ZONING, ELECTRICAL, X v MECHANICAL, PLUMBING, LIFE SAFETY & FIRE CODES. CONTRACTORSHALL VERIFY ALL CODE M0.1 MECHANICAL NOTES 05.07.2021 w NORTH REQUIREMENTS IN THE COSTRUCTI0N DOCUMENTS TO THE ATTENTION OF THE ARCHITECT. M2.1 MECHANICAL PLAN 05.07.2021 - - OX WINDOW TYPE TAG B. CONSTRUCTION DOCUMENTS SHALL COMPLY WITH. UU)) M2.1.1 MECHANICAL PLAN 05.07.2021 X ST, LUCIE COUNTY LAND DEVELOPMENT CODE PLUMBING � XXX ELEVATION FLORIDA BUILDING CODE, 2020, 7th EDITION - EXISTING BUILDING XXX DOOR TYPE TAG FLORIDA BUILDING CODE, 2020, 7th EDITION - BUILDING P0.1 PLUMBING NOTES 05.07.2021 • FLORIDA BUILDING CODE, 2020, 7th EDITION -ACCESSIBILITY P2.1 SANITARY PLAN 05.07.2021 • FLORIDA FIRE PREVENTION CODE, 2020, 7th EDITION CEILING HT. VERTICAL ELEVATION • NFPA 101 2020 P2.1.2 SANITARY PLAN 05.07.2021 X @ EL.# TAG AMERICANS WITH DISABILITIES ACT(ADA) XXX BUILDING / WALL P3.1 DOMESTIC WATER PLAN 05.07.2021 SECTIONS 1,03 PERMITS P3.1.1 DOMESTIC WATER PLAN 05.07.2021 REVISION TAG THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED BUILDING AND TRADE PERMITS AND THEIR RESPECTIVE COSTS. P-5.1 PLUMBING ISOMETRICS 05.07.2021 m _�e m U_ L-LJ X 1.04. JOB CONDITIONS: L J XXX DETAIL XX.XX MATERIAL OR TILT PANEL KEYNOTE A. THE CONTRACTOR SHALL VISITTHE PROJECT SITE PRIOR TO SUBMITTAL OF BID AND/ORCONTRACT E > a NEGOTIATIONS AND SHALL VERIFY EXISTING CONDITIONS WITH THE CONSTRUCTION DOCUMENTS. z ROOM DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS (AND THEIR INTENT) SHALL BE BROUGHTTO t°L X/ INTERIOR ELEVATIONS NAME ROOM TAG THE ARCHITECT'S ATTENTION FOR CLARIFICATION IN WRITING. BIDS SHALL NOT BE NOT BE SUBMITTED o XXX OR CONSTRUCTION CONTRACTS NEGOTIATED BY THE CONTRACTOR PRIOR TO THE CLARIFICATION OF d THE INTENT OF THE CONSTRUCTION DOCUMENTS WHERE SUCH INTENT IS IN DOUBT. DRAWING NUMBER B. DIMENSIONS AND NOTES SHALL TAKE PRECEDENCE OVER SCALE AND GRAPHICS. DRAWING TITLE TITLE 1 SHEET NUMBER 1.05 WORK NECESSARY TO COMPLETE CONSTRUCTION W SCALE: A-'I.01 IT IS THE PURPOSE OF THESE PLANS AND SPECIFICATIONS TO DESCRIBE A COMPLETE AND FINISHED PROJECT U_ OTHER THAN ITEMS MARKED "N.I C."(NOT IN CONTRACT. W Q 1.06 CLEAN UP/ REPAIR . z A. THE CONTRACTOR SHALL MAINTAIN THE PREMISED CLEAD AND FREE OF ALL TRASH, DEBRIS AND SHALL Q PROTECTALL ADJA CENT WORK FROM DAMAGE, SOILING, P A I NT 0 VERSPRAY, ETC. ALL FIXTURES, LL1 EQUIPEMENT, GLAZING FLOOR, ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON Z Q COMPLETION OF THE PROJECT. 00 B. THE CONTRACTOR SHALL REPAIR AND/OR REPLACE ALL EXISTING ITEMS DAMAGED BY THE PROCESS OF NEW CONSTRUCTION AND SHALL FINISH ALL PATCHWORK AND REPAIRS TO MATCH EXISTING ADJACENT I-_ z AREAS AND SURFACES. W 1.07 SHOP DRAWINGS THE CONTRACTOR SHALL SUBMIT ELECTRONIC SETS OF SHOP DRAWINGS OF ALL FABRICATED ITEMS AND m m EQUIPMENT FOR OWNER'S /ARCHITECT'S REVIEW PRIOR TO FABRICATION AND COMMENCEMENT WITH THE Q 06 XU) LLJ LLJ 1.08 ALLOWANCES : I-_ FIXTURES, EQUIPMENT, HARDWARE AND FINISHES NOT SPECIFIED SHALL BE PROVIDED FOR IN THE Z O CONTRACTOR'S BID AS LINE ITEM ALLOWANCES ON A SCHEDULE OF VALUES. {7 J 1.09 SCHEDULE E - � THE CONTRACTOR SHALL DELIVER TO THE OWNER, AS PART OF THE BID DOCUMENTS,THEIR PROPOSED z �j W SCHEDULE FOR CONSTRUCTION, INCLUDING COMMENCEMENT OF WORK THROUGH CERTIFICATE OF �' Of W OCCUPANCY AND SHALL INCLUDE PRODUCT AM WORKMANSHIP WARRANTY PERIODS. @ 0 (D p � N � p p O N N j N � N Q a) I p c E z� z Qj m z U d N a) p O N d d