Loading...
HomeMy WebLinkAbout2020-0562E0-1-E0-1 S E S C 0 ELECTRICAL SPECIFICATIONS ELECTRICAL SHEET INDEX 7 = N TELEPHONE WOOD BACKBOARD m M o 0 LIGHTING FIXTURE SCHEDULE 4 Wx8 Hx3/4 BC PLYWOOD E0.1 ELECTRICAL NOTES, LEGEND & INDEX i 8 PAINT WITH TWO COATS OF PART 1 - GENERAL ml; a�i LAMPS FIRE RETARDANT WHITE PAINT 1-2" CONDUIT WITH PULL A. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NEW ELECTRICAL WORK INDICATED. E1.1 SITE PHOTOMETRIC PLAN 9 TYPE MANUFACTURER CATALOG NUMBER DESCRIPTION DIMMING VOLTS MOUNTING REMARKS STRING TO MAIN CONSTRUCTION SHALL BE IN ACCORDANCE WITH DRAWINGS AND APPLICABLE SPECIFICATIONS. f Qty Type Total Wattage T iff u o TELEPHONE BOARD ON IF A PROBLEM IS ENCOUNTERED IN COMPLYING WITH THIS REQUIREMENT, CONTRACTOR SHALL NOTIFY E1.2 SITE POWER PLAN 0-10V WHERE - ~ A H.E.WILLIALMS GHQ-L480B40 HA-FA-DM THE ARCH AS SOON AS POSSIBLE AFTER DISCOVERY OF THE PROBLEM AND /UNV MODULAR LED HIGHBAYWITH FROSTED ACRYLIC LENS AND HIGH AMBIANT OPERATING TEMP INCL LED 327.9 UNV SURFACE 1 - FLOOR Q aLU SHOWN ON PLAN 1 c SHALL NOT PROCEED WITH THAT PORTION OF THE WORK UNTIL ARCHITECT/ENGINEER HAS DIRECTED o t m TO BRANCH E2.1 LIGHTING PLAN >_t C 0-10V WHERE CORRECTIVE ACTION TO BE TAKEN. _ AEM H.E.WILLIALMS GHQ-L480/840-HA-FA-EM/20W-DIM-UNV MODULAR LED HIGHBAYWITH FROSTED ACRYLIC LENS AND HIGH AMBIANTOPERATNGTEMP&EM INCL LED 327.9 UNV SURFACE 1 CIRCUIT PANEL B. THE CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND FAMILIARIZE HIMSELF WITH ALL `- ° Q SHOWN ON PLAN U 3 N LL ' O 0-10V WHERE LCONDITIONS AFFECTING ELECTRICAL AND COMMUNICATIONS INSTALLATION AND MAKE PROVISIONS AS TO E2.1.1 LIGHTING PLAN T B BEGHELLIUSA BS101ECO-4HT-WT40-120-277V 4'LED VAPORPROOF INCL LED 55 UNV SURFACE 1 o N L v SHOWN ON PLAN THE COST THEREOF. 6 In o C. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC E2.3 PHOTOMETRIC PLAN o C w 0-10V WHERE N d cn BEM BEGHELLIUSA BS101ECO�SA-WT40-120-277V 4'LED VAPORPROOF WITH EM INCL LED 55 UNV SURFACE 1 a m SHOWN ON PLAN CODE (AS ADOPTED BY THE AUTHORITY HAVING JURISDICTION) AND ALL CODES AND ORDINANCES OF THE AUTHORITY HAVING JURISDICTION. THE SPECIFICATION, CODES AND STANDARDS LISTED BELOW ARE E2.3.1 PHOTOMETRIC PLAN X BEGHELLIUSA VA4-R-SA POLYCAROBNATE LED EXITWFfH BATTERY INCL LED 2 N/A UNV UNNERSAL 1,2 UTILIZED IN THIS PROJECT. TERMINATE CONDUIT WITH 1. NATIONAL ELECTRICAL CODE (NFPA-70) E2.4 EMERGENCY PHOTOMETRIC PLAN O O 41- INSULATED BUSHING 2. CODE FOR SAFETY TO LIFE (NFPA-101) LIGHTING SCHEDULE NOTES: MOUNT RECEPTACLE 3. STANDARD FOR THE INSTALLATION, MAINTENANCE AND USE OF LOCAL PROTECTIVE SIGNALING E2.4.1 EMERGENCY PHOTOMETRIC PLAN DIRECTLY TO TELEPHONE SYSTEMS (NFPA-72) U 1. PROVIDE SUBMITTALS FOR ARCHITECT/ENGINEER REVIEW PRIOR TO ORDERING. NOSUBSTITUTIONS ALLOWED. 4.BOARD 5. UNDNATERWRITENAL RS' LABORATORIES MANUFACTURERS ASSOCIATION (NEMA) E3.1 POWER PLAN 2. FINISH COLOR SELECTED BYARCHITECT 6. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) E3.1.1 POWER PLAN 7. FEDERAL SPECIFICATION (FED. SPEC.) 8. INSULATED POWER CABLE ENGINEERS ASSOCIATION (IPCEA) E5.1 ELECTRICAL RISER DIAGRAM C0 GROUND BAR, SEE DETAIL 9. FLORIDA BUILDING CODE. FBC 2020 EDITION z THIS SHEET. 10. INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE) 11. CITY OF FORT PIERCE BUILDING CODE. (AMENDMENTS TO FLORIDA BUILDING CODE FBC 2020) E6.1 PANEL SCHEDULES O 1 #2 GROUND 12. ADDITIONALLY, DESIGNS, WORK PRACTICES AND CONDITIONS MUST CONFORM WITH THE 0 TO NEAREST EFFECTIVELY OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA) GROUNDED BUILDING - D. DO NOT SCALE THE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS STRUCTURAL STEEL MEMBER. = FOR EXACT LOCATION OF ALL EQUIPMENT. CONFIRM WITH OWNER'S REPRESENTATIVE. O 01 E. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE LL m CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM ELECTRICAL LEGEND AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. F___ F. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FROM A O PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE. TELEPHONE OUTLET WITH 3/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. z G. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE 0 MOUNT 18" A.F.F. TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. TELEPHONE RISER DIAGRAM REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THERE BY. DATA OUTLET WITH 3/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. NOT TO SCALE H. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY AND V MOUNT 18" A.F.F. TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. LLI PROPERTY DAMAGE FOR THE DURATION OF THE WORK. (/) CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTING. CONTRACTOR TELEPHONE/DATA OUTLET WITH 3/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT. MOUNTED ABOVE COUNTER, SEE ARCHITECTURAL DRAWING FOR SPECIFIC REQUIREMENTS. THE TERM "PROVIDE" USED IN THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL MEAN THAT ~ 10ll THE CONTRACTOR IS TO FURNISH, INSTALL AND CONNECT COMPLETE. TELEPHONE/DATA OUTLET WITH 3/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. PART 2 - PRODUCTS 0 MOUNT 18" A.F.F. TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. EQUIPMENT GROUNDS A. MINIMUM WIRE SIZE SHALL BE #12 A.W.G. EXCEPT AS NOTED OTHERWISE FOR CONTROL WIRING ^ CONDUCTORS SHALL BE 98% CONDUCTIVITY, COPPER WITH "THHN-THWN" INSULATION UNLESS OTHERWISE TELEPHONE/DATA OUTLET WITH 3/4" CONDUIT RUN TO THE NEAREST STUD WALL AND 0- NOTED. STUBBED OUT FROM WALL 6 ABOVE CEILING. PROVIDE BRASS COVER PLATE AND � B. ELECTRICAL METALLIC TUBING (EMT) SHALL BE OF BEST QUALITY STEEL, SMOOTH INSIDE AND OUT CARPET FLANGE. AND SHALL BE HOT-DIPPED GALVANIZED. TELEVISION OUTLET WITH 1-1/4" CONDUIT STUBBED OUT FROM WALL 6" ABOVE CEILING. CV O 00 1-1/2" 0 O O o O 0 C. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS MOUNT AT 18" A.F.F. TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED. O 0') rn ca CD I. IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. N [� M LO D. RIGID NONMETALIC CONDUIT SHALL BE SCHEDULE 40 PVC. (� 20 AMP SINGLE RECEPTACLE (NEMA 5-20R) MOUNTED AT 18 A.F.F. TO CENTER LINE OF MMh��� ai L: ALL MATERIALS SHALL BE NEW AND BEAR UNDERWRITERS' LABELS WHERE APPLICABLE. �l' OUTLET UNLESS NOTED OTHERWISE. Q u- MOUNTED AT BASE OF O m N ' F. PANELBOARDS: (m 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R) MOUNTED AT 18 A.F.F. TO CENTER LINE OF W M PLYWOOD BACKBOARD �i' Z 1. CURRENT CARRYING BUSES SHALL BE COPPER. GROUND BUS BARS SHALL BE COPPER. OUTLET UNLESS NOTED OTHERWISE. Lf� Q x 3-0 A.F.F. 2. ALL CIRCUIT BREAKERS SHALL BE BOLT ON. PLUG-IN BREAKERS ARE NOT ACCEPTABLE. CDz - LPL 3. CIRCUIT BREAKERS USED AS SWITCHES IN FLUORESCENT OR HID LIGHTING CIRCUITS SHALL 20 AMP QUADRUPLEX RECEPTACLE (NEMA 5-20R) MOUNTED AT 18 A.F.F. TO CENTER LINE _0 OF OUTLET UNLESS NOTED OTHERWISE. [� C � BE LISTED AND MARKED SWD 0 m cal 4. ALL CIRCUIT BREAKERS FEEDING MECHANICAL EQUIPMENT SHALL BE HACR TYPE. ((nGFI 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R) WITH GROUND FAULT CIRCUIT INTERRUPTER, O C 1/4" COPPER BAR `I I' MOUNT AT 18 A.F.F. TO CENTER LINE OF OUTLET. UNLESS NOTED OTHERWISE. � a o 5. A.I.C. RATINGS SHALL BE AS INDICATED ON PANELBOARD SCHEDULES. 6. ALL PANELBOARDS SHALL BE FURNISHED WITH PLASTIC LAMINATE NAMEPLATES WITH 1/4" } 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R) MOUNTED ABOVE COUNTER 0 , „/ a . N ENGRAVED LETTERING FOR PANEL IDENTIFICATION. `I I' SEE ARCHITECTURAL DRAWINGS FOR SPECIFIC REQUIREMENTS. ' I-� b-`� I- LULU ti GLASTIC INSULATOR 7. ALL PANELBOARDS SHALL BE PROVIDED WITH TYPE-WRITTEN DIRECTORY OF BRANCH CIRCUIT 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R) WITH ISOLATED GROUND, MOUNT AT 18" A.F.F. P o DESIGNATIONS. TO CENTERLINE OF OUTLET UNLESS OTHERWISE NOTED. Q m C" PLYWOOD BACKBOARD G. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK-MAKE, QUICK-BREAK. ENCLOSURES SHALL BE NEMA-1 FOR INDOOR LOCATIONS, NEMA 3R FOR OUTDOOR LOCATIONSOR AS OTHERWISE NOTED. A.F.F.AMP Q CENTER RECEPTACLE (NEMA 5-20R) WITH ISOLATED GROUND, MOUNT AT 18" LEE SIDE VIEW A. TO CENTERLINE OF OUTLET UNLESS OTHERWISE NOTED. H. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC AS INDICATED ON THE ELECTRICAL DRAWINGS, WITH 10 OVERLOAD RELAYS IN EACH PHASE. 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R), RECESS FLOOR MOUNTED. PROVIDE BRASS WIRING DEVICES (GENERAL PURPOSE RECEPTACLES AND WALL SWITCHES) COLOR SHALL BE COORDINATED COVER PLATE AND CARPET FLANGE. WITH EQUIPMENT GROUND-> TELEPHONE WOOD BACKBOARD TELEPHONE GROUNDING BAR PART3c- EXECUTION ®i 20 AMP DUPLEX RECEPTACLE (NEMA 5-20R), CEILING MOUNTED. 4'Wx8'Hx3/4" GRADE BC NOT TO SCALE A. COLOR CODING OF CONDUCTORS SHALL BE AS FOLLOWS: SPECIAL-PURPOSE RECEPTACLE PLYWOOD. PAINT WITH TWO 1. 208/120 VOLTS, 3 PHASE, 4-WIRE SYSTEM: UNGROUNDED CONDUCTORS: 1 BLACK, 1 RED AND 1 0 JUNCTION BOX 0 O O o O 0 COATS OF FIRE RETARDANT BLUE. GROUNDED (NEUTRAL) CONDUCTOR; WHITE. GROUNDING CONDUCTORS SHALL BE GREEN. TO BRANCH WHITE PAINT. 2 1 0/277 VOROUNDED (NEUTRAL) CONDUCTORS;UNGROUNDED D CONDUCTORS: COBS: 1 BROWN, 1 YELLOW, AND Q� P SINGLE GANG JUNCTION BOX FOR POWER CONNECTION TO MODULAR FURNITURE SYSTEM CIRCUIT PANEL INSTALL IN EXACT MANNER AS DIRECTED BY FURNITURE SUPPLIER. I i=l3. BRANCH CIRCUIT WIRING (#6 AND SMALLER) SHALL BE COLOR CODED BY CONTINUOUS INSULATION COLOR AND FEEDERS AND SERVICES (#4 AND LARGER) SHALL BE CODED AT ALL JUNCTION OR MOUNTED AT BASE OF PULL POINTS (EXCEPT LB'S OR LBD'S) USING COLOR MARKERS OR PLASTIC TAPE MANUFACTURED OT/D DOUBLE GANG JUNCTION BOX FOR TELEPHONE/DATA CONNECTION TO MODULAR FURNITURE PLYWOOD BACKBOARD I FOR THE PURPOSE. SYSTEM. INSTALL IN EXACT MANNER AND LOCATION AS DIRECTED BY FURNITURE 3'-0" A.F.F. B. WIRING METHODS SUPPLIER. EXTEND (2) 3/4 EMPTY CONDUITS FROM JUNCTION BOX TO ABOVE Q CATV WOOD BACKBOARD 1. ALL CONDUCTORS SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING (EMT) UNLESS CEILING AND TERMINATE WITH INSULATING BUSHING 6" FROM WALL. Z 1/4" COPPER BAR 4 Wx8'Hx3 4�� GRADE BC OTHERWISE NOTED, SPECIFIED OR AS SPECIFICALLY PROHIBITED BY THE AUTHORITY HAVING / TELE/POWER POLE FOR TELEPHONE/DATA/POWER CONNECTION TO MODULAR FURNITURE JURISDICTION. ALL FITTINGS AND COUPLINGS FOR EMT CONDUIT SHALL BE ALL STEEL Q � PLYWOOD. PAINT WITH TWO RAIN TIGHT COMPRESSION TYPE OR ALL STEEL CONCRETE TIGHT SET SCREW TYPE. 8 WIRE SYSTEM (SEE DETAIL THIS SHEET). INSTALL IN EXACT MANNER AND LOCATION �_ O TERMINATE CONDUIT WITH COATS OF FIRE RETARDANT AS DIRECTED BY FURNITURE SUPPLIER, WIREMOLD CATALOG # 25DTP-4D W/IVORY FINISH. MOUNT RECEPTACLE 2. SCHEDULE 40 PVC CONDUIT, WITH FITTINGS AND COUPLINGS APPROPRIATE FOR THE USE, SHALL (6 J GLASTIC INSULATOR INSULATED BUSHING TO BRANCH WHITE PAINT BE INSTALLED UNDERGROUND OR BELOW SLABS ON GRADE. O DIRECTLY TO TELEPHONE CIRCUIT PANEL SPECIAL PURPOSE RECEPTACLE MOUNTED BELOW RAISE FLOOR. 3. TYPE MC CABLE WITH ALUMINUM ARMOR AND INTERNAL GROUND IS ACCEPTABLE FOR PLYWOOD BACKBOARD BOARD USE AS GENERAL BRANCH CIRCUIT WIRING FOR CIRCUITS 20 AMPERES OR LESS AND CONCEALED `' M 2 SETS OF 2" CONDUITS WITH IN WALLS OR ABOVE SUSPENDED CEILING AND AS APPROVED BY THE AUTHORITY HAVING EF EXHAUST FAN. SEE MECHANICAL DRAWINGS FOR SPECIFICATIONS. U i �-�° ii SIDE VIEW PULLSTRING TO MAIN TELEPHONE JURISDICTION. SERVICE CONNECTION POINT. C. ELECTRICAL SYSTEM SHALL BE COMPLETE AND EFFECTIVELY GROUNDED AS REQUIRED BY THE LATEST $ SINGLE POLE 20 AMP SWITCH. MOUNT 46 A.F.F. TO CENTERLINE OF SWITCH UNLESS GROUND BAR, SEE DETAIL > EDITION OF THE N.E.C. AND LOCAL CODES. OTHERWISE NOTED. d o_ THIS SHEET. VERIFY LENGTH OF RUN PRIOR D. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS C o L BID. SEE SITE LOCATION PLAN WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTED BY $3 3-WAY, 20 AMP, SWITCH. MOUNT 46" A.F.F. TO CENTERLINE OF SWITCH UNLESS G U M LLL TELEPHONE GROUNDING BAR 1 #2 GROUND ON THIS SHEET FOR REFERENCE. ENGINEER/ARCHITECT. OTHERWISE NOTED. NOT TO SCALE TO NEAREST EFFECTIVELY TERMINATE CONDUIT WITH E. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS GROUNDED BUILDING = MOUNT RECEPTACLE INSULATED BUSHING OF CONSTRUCTION. $D SINGLE POLE, 20 AMP, SWITCH WITH DIMMER. MOUNT 46" A.F.F. TO CENTERLINE OF SWITCH U STRUCTURAL STEEL MEMBER. = DIRECTLY TO CATV F. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER AND TELEPHONE UNLESS OTHERWISE NOTED. BOARD COMPANIES, AND SHALL BE FULLY COORDINATED WITH THEM PRIOR TO COMMENCEMENT OF WORK. MOTOR RATED SWITCH 2 SETS OF 2" CONDUITS WITH G. PROVIDE AND INSTALL CONDUIT, CONDUCTORS, PULL WIRES, BOXES, COVER PLATES, AND WIRING M DEVICES, FOR ALL OUTLETS AS INDICATED. VACANCY SENSOR SWITCH, WATTSTOPPER, MOUNT 46" A.F.F. TO CENTERLINE OF SWITCH O PULLSTRING TO MAIN CABLE H. MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW UNLESS OTHERWISE NOTED. .V) GROUND BAR, SEE DETAIL SERVICE CONNECTION POINT. AND SUCH AS APPEAR ON THE UL LIST OF APPROVED ITEMS AND SHALL MEET OR EXCEED THE C:THIS SHEET VERIFY LENGTH OF RUN PRIOR REQUIREMENTS OF NEC, NEMA, AND IECE. $ TWO POLE, 30 AMP SWITCH. MOUNT ADJACENT EQUIPMENT TO BE CONTROLLED. TO BID. CONTRACTOR SHALL SUBMIT AT LEAST FIVE (5) SETS OF SHOP DRAWINGS OR CUT SHEETS OF LIGHTING Q 1 #2 GROUND FIXTURES, SWITCHES, AND OTHER ELECTRICAL ITEMS FOR APPROVAL BY ENGINEER/ARCHITECT. X TELEPHONE RISER DIAGRAM TO NEAREST EFFECTIVELY CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING REQUIRED OF HIS WORK. ® FACTORY MOUNTED DISCONNECT/STARTER (SEE MECHANICAL SCHEDULE) Lu K. ALL LAY-IN LIGHTING FIXTURES SHALL BE SECURED TO THE SUSPENDED CEILING GRID AT EACH CORNER. NOT TO SCALE GROUNDED BUILDING _ L. CONTRACTOR SHALL COORDINATE WITH MECHANICAL DRAWINGS AND PROVIDE ALL NECESSARY CONTROL IO ABC FUSIBLE DISCONNECT SWITCH A = POLES, B= FRAME SIZE, C= FUSE RATING STRUCTURAL STEEL MEMBER. - WIRING. N M. ALL ELECTRICAL POWER WIRING FOR THE HVAC SYSTEM INCLUDING WIRING THRU LINE VOLTAGE CONTROL U) DEVICES SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. � Ac FUSIBLE MOTOR STARTER DISCONNECT SWITCH A = POLES, B= NEMA SIZE, C= FUSE RATING (a �0 W VOLTAGE SWITCH D ETA I � N. THE CONTRACTOR SHALL CONFIRM WITH THE ELECTRICAL UTILITY COMPANY ANY AND ALL REQUIREMENTS � GROUNDING ELECTRODE & CONDUCTOR SYSTEM � SUCH AS: METERING EQUIPMENT REQUIREMENTS AND METERING EQUIPMENT LOCATION, TRANSFORMER SIZE AND LOCATION OR SERVICE POINT, CONDUIT ENTRY AND LUG SIZE RESTRICTIONS. THE CONTRACTOR SHALL SCHEDULE ALL REQUIRED DOWN TIME FOR THE OWNERS CONFIRMATION. T1 TRANSFORMER ANY CONFLICTS AND DESCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE O CABLE TV RISER DIAGRAM 0. PROCEEDING WITH ANY WORK. p ELECTRICAL PANELBOARD NOT TO SCALE PER NEC 210.8(B)(2) ALL 15- AND 20-AMPERE, 125-VOLT RECEPTACLES IN NONDWELLING-TYPE KITCHENS GENERAL N OTES TO BE GFCI PROTECTED. � TELEPHONE WOOD BACKBOARD m TM P•BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3% DESIGN LOAD. FBC 2020 O L i g h t S yn c G 2 D a t a I i n e S W I t c h D e t a i l FBC ENERGY CONSERVATION SECTION 405.7.3. WP WEATHERPROOF m > m 79 Switch Insert Q. FEEDER CONDUCTORS SHALL BE SIZED FOR A MAXIMUM OF 2% VOLTAGE DROP PER 405.7.3. T/C TIME CLOCK U U A. ALL EQUIPMENT TO BE BY INTELLIGENT LIGHTING CONTROLS, INC. Address Setting Wheels (2) Cut-out ype RE RELOCATED .� ON-SITE SYSTEM COMMISSIONING SHALL BE REQUIRED. 15 Position E 0 o E EXISTING TO REMAIN z COMMISSIONING OF SYSTEMS VIA MODEM WITHOUT ON-SITE SUPPORT o o to SHALL NOT BE ACCEPTED. (0) ° A.F.F. ABOVE FINISH FLOOR 9 O CEILING MOUNTED DUAL TECHNOLOGY MOTION SENSOR BY WATTSTOPPER. B. ELECTRICAL CONTRACTOR TO PROVIDE CAT-5 DATA CABLE. o ° 1,17 SEE CAT-5 REQUIREMENTS SHEET & RJ45 CONNECTOR DETAIL. TEST ALL CABLE LENGTHS AND TERMINATION'S W/CAT-5 TESTER. o0 3,249 1 71 OLV CEILING MOUNTED LOW VOLTAGE DUAL TECHNOLOGY MOTION SENSOR BY WATTSTOPPER. 1.83 O CEILING MOUNTED DAY LIGHTING SENSOR. SENSOR TO CONTROL THE DIMMING OF ALL FIXTURES C. ALL LOW VOLTAGE COMMUNICATION CABLE & HARDWIRE LOW DS WITHIN 15' OF THE WINDOWS WITH IN ROOM. VOLTAGE CONTROL WIRING TO BE INSTALLED PER NATIONAL 0 i ELECTRICAL CODE FOR CLASS-2 LOW VOLTAGE WIRING. BACK FRONT DEPTH 1-1/8" HOLE FOR FOR #6-32 D. CLASS-2 LOW VOLTAGE WIRING SHALL NOT BE MIXED WITH OR RJ-45/CAT-5 JACK (2) #6-32 THREADED RUN IN LINE VOLTAGE RACEWAYS. SEPARATE LOW VOLTAGE RUNS FROM LINE VOLTAGE BY A MINIMUM DISTANCE OF 1 -FOOT. LIGHTING CONTROL SYSTEM E. CAT-5 DATA CABLE RUNS TO BE INSTALLED IN A DAISY CHAIN FROM ONE PANEL OR DEVICE TO THE NEXT. NO "STAR" OR "T" LINE RISER CONFIGURATIONS ALLOWED WITHOUT POWER SUPPLY REPEATERS. F. ALL CLASS-2 & CAT-5 DATA CABLE RUNS TO BE PROVIDED AND INSTALLED WITH THE APPROPRIATE JACKET TYPE OR CONDUIT ° ° FOR THE INSTALLATION ENVIRONMENT OR CONDITIONS ON SITE. H G. EACH LIGHTING RELAY PANEL REQUIRES A DEDICATED 120V. o O 0 a OR 277V. CIRCUIT FOR CONTROL POWER TRANSFORMERS. °%'-' line G2 LV Switch G2 LV Switch G2 LV Switch v s H. ADDITIONAL ILC POWER OR DATA REPEATING DEVICES MAY BE REQUIRED F load m a m H FOR PROPER SYSTEM OPERATION, BASED ON THE ACTUAL NUMBER r (typical of up to 4) " AND DISTANCE OF LightSync DEVICES TO BE INSTALLED ON CAT-5 A0 ° a DATA LINE. CONTACT AMY LEE @ SESCO LIGHTING 954-474-9888. o ILC APPRENTICE II RELAY PANEL LO CD O CAT5 CABLE WITH RJ45 CONNECTORS Digitally signed by Bradly ISSUED FOR PERMIT ONLY 05-07-21 O N OC\j O NOT FOR PRICING OR CONSTRUCITON N Cfl Bra L L Brown P.E. � N - KAMM CONSULTING PROJECT#: 2020-0562 -0 E DN: cndly L Brown E D PROJECT MANAGER: JOHN MAYR P.E., o=Kamm Consulting 1408 Orange Avenue !� 0 r o w n Inc. ou-FL# 58232 MM Fort Pierce,Florida 34950 O - � Phone 954.448.0792 jmayr@kammconsulting.com D_ D_ e m a I I=j m a y r@ ka m m eo n S COneUmng Certification of Authorizati on#8189 ulting.com, c=US PRINCIPAL 06-21-21 Bradly L Brown Florida License#58232 dateE Date: 2021 .06.21 12:32:41 -04'00' signed