Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2020-0562E5-1-E5-1
PHASE 2 PHASE 2 INTERIOR EXTERIOR INTERIOR Q a Y N 1 1 ° s o C? m a O N M C U� L N � � PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL Y MDP1 1200 A METER METER 1200 A MDP2 "21-4" "21LY "2A" "2B" "2C" "2G" MAIN MAIN "2D" "2E" "21`" 0*2L1" "21L2" 0*21-5" ` LU FPUA TVSS O TVSS O - 7 7 7 7 7 7 GFCI CT O TRANSFORMER O CT GFCI 7 7 7 7 7 7 ~ O O O O O O -� -� O O O O O O -o n m a 1200A 277/480V 1200A 3@0 0 0 XFMR XFMR U N LL I Q N� c O U N � G T1 A 6T1 A n s6 o a MDP1- MDP1- V s � � L w MDP1- MDP1- � MDP2- MDP2- MDP2- 4-#4/0 & 1#2G IN 2-1/2" v--] 1 1 4- 4 0 & 1 2G IN 2-1/2" FF °' >�`� � � N M Z o SCHEDULE2 IN 340 PVC SCHEDULE 404 PVC O BLDG DEPT COMM 06-04-21 II 3#2 & 1#6G IN 1-1/4" _ U 3 SETS - 4-600MCM & 1#3/OG - 4" 6 G G G 6 ELECTRICAL RISER NOTES C0 z p 1 G 2 2 1 �O. (�V4 EXOTHERMIC CONNECTION. (TYPICAL) O C/W �O Z�G �0,, "JJ C/W O1 1# 4/0 GROUNDING ELECTRODE CONDUCTOR 0 G _ G G _ G IN 1 SCHEDULE 40 PVC CONDUIT. O MAKE CONNECTION TO METALLIC COLD WATER O EXOTHERMIC CONNECTION. ELECTRICALLY CONT- ENTRANCE PIPE BEFORE FIRST VALVE WITH 4 4 INUOUS STEEL REINFORCING BAR IN BOTTOM OF HEAVY DUTY BRONZE GROUND CLAMP. U) G G BUILDING FOUNDATION IN DIRECT CONTACT WITH g PROVIDE 1 3 0 BONDING JUMPER AROUND 3 3 = EARTH. O FIRST VALVE. / ~ 10'-0" 10'-0" O3 10 FT. LONG x 3/4" DIAMETER COPPER DRIVEN O GROUND ELECTRODE. O 100% RATED GEAR. Z NEW ELECTRICAL RISER DIAGRAM Lu C0 � U SCHEDULE OF BRANCH CIRCUIT PANEL "2L1" SCHEDULE OF BRANCH CIRCUIT PANEL r2A" SCHEDULE OF BRANCH CIRCUIT PANEL "2C" MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER (PROVIDE WITH FEED THRU LUGS) VOLTAGE: 208/120V, 30, 4 WIRE MAIN: 100 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE MAIN: 600 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE w SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 22,000 MOUNTING: FLUSH AIC SYMM: 18,000 MOUNTING: FLUSH AIC SYMM: 18,000 I-�I A PHASE B PHASE C PHASE A PHASE B PHASE C PHASE A PHASE B PHASE C PHASE co DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION (V O00 KVA KVA KVA KVA KVA KVA KVA KVA KVA O c9 RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES SPARE - - - 20 1 - - 2 20 - - - SPARE LIGHTING #12 #12 1 2" 20 1 3.5 - 2 20 - - - SPARE N co LO DROP CORD POWER #12 #12 1 2" 20 3 0.8 0.8 4 20 1 2" #12 #12 DROP CORD POWER SPARE - - - 20 3 - - 4 20 - - - SPARE LIGHTING #12 #12 1 2" 20 3 3.5 - 4 20 - - - SPARE DROP CORD POWER #12 #12 1 2 20 5 0.8 0.8 6 20 1 2 #12 #12 DROP CORD POWER SPARE - - - 20 5 - - 6 20 - - - SPARE LIGHTING #12 #12 1 2 20 5 3.5 3.5 6 20 1 2 #12 #12 LIGHTING Q DROP CORD POWER #12 #12 1 2" 20 7 0.8 0.8 8 20 1 2" #12 #12 DROP CORD POWER SPARE - - - 20 7 - 0.9 8 15 1/2" 1#12 3#12 BIG ASS FAN LIGHTING #12 #12 1 2" 20 7 3.5 3.5 8 20 1 2" #12 #12 LIGHTING DROP CORD POWER #12 #12 1 2 20 9 0.8 0.8 10 20 1 2 #12 #12 RECEPTACLES SPARE - - - 20 9 - 0.9 10 LIGHTING #12 #12 1 2 20 9 1.8 0.8 10 20 1 2 #12 #12 LIGHTING �i w I- RECEPTACLES #12 #12 1 2" 20 11 0.8 0.8 12 20 1 2" #12 #12 DROP CORD POWER SPARE - - - 20 11 - 0.9 12 3 LIGHTING #12 #12 1 2" 20 11 0.8 13.3 12 60 1" 1#10 3#6 DUPLEX VACUUM PUMP Lf'� U � x DROP CORD POWER #12 #12 1 2" 20 13 0.8 0.8 14 20 1 2" #12 #12 DROP CORD POWER BIG ASS FAN 3#12 1#12 1/2" 15 13 0.9 - 14 20 - - - SPARE EF-SP1 3#3 1#8 1-1/4" 110 13 18.0 13.3 14 O Z - LL DROP CORD POWER #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 DROP CORD POWER 15 0.9 - 16 20 - - - SPARE 15 18.0 13.3 16 3 DROP CORD POWER #12 #12 1 2" 20 17 0.8 0.8 18 20 1 2" #12 #12 DROP CORD POWER 3 17 0.9 - 18 20 - - - SPARE 3 17 18.0 18.0 18 110 1-1/4" 1#8 3#3 EF-SP2 � O m N RECEPTACLES #12 #12 1 2 20 19 0.8 0.8 20 20 1 2 #12 #12 RECEPTACLES BIG ASS FAN 3#12 1#12 1 2 15 19 0.9 - 20 20 - - - SPARE EF-G3 3#6 1#10 1" 80 19 7.5 18.0 20 �7 p c RECEPTACLES #12 #12 1 2" 20 21 0.8 1.2 22 20 1 2" #12 #12 DOOR POWER 21 0.9 - 22 20 - - - SPARE 21 7.5 18.0 22 3 �- l 3 o FIRE ALARM POWER #12 #12 1 2 20 23 1.0 1.8 24 20 1 2 #12 #12 AHU-3 CU-3 POWER 3 23 0.9 - 24 20 - - - SPARE 3 23 7.5 7.5 24 80 1" 1#10 3#6 EF-G1 W �•J Q N DOOR POWER 2#12 1#12 1/2" 2 25 0.5 0.5 26 2 1/2" 1#12 2#12 DOOR POWER SPARE - - - 20 25 - - 26 20 - - - SPARE EF-G2 3#6 1#10 1" 80 25 7.5 7.5 26 // F-�-I r-- 2 27 0.5 0.5 28 2 SPARE - - - 20 27 - - 28 20 - - - SPARE 27 7.5 7.5 28 3 F-�-I Z � ti DOOR POWER 2#12 1#12 1/2" 2 29 0.5 0.7 30 2 1/2" 1#12 2#12 DOOR POWER SPARE - - - 20 29 - - 30 20 - - - SPARE 3 29 7.5 18.0 30 110 1-1/4" 1#8 3#3 RAU-SP1 m o 2 31 0.5 0.7 32 2 SPARE - - - 20 31 - 0.8 32Z151/2" 1#12 3#12 BIG ASS FAN RAU-S1 3#3 1#8 1-1/4" 100 31 18.0 18.0 32 Q ^ m NDOOR POWER 2#12 1#12 1 2 2 33 0.7 0.7 34 2 1 2 1#12 2#12 DOOR POWER SPARE - - - 20 33 - 0.8 34 32 35 - 0.7 36 SPARE - - - 20 35 - 0.8 36 3 35 18.0 3.2 36 60 1" 1#10 3#6 RAU-SG1 AHU-1/ CU-1 POWER 2#8 1#10 3/4" 4 37 2.5 0.8 36 3 3 4 I#10 2#10 COMPACTOR SPARE - - - 20 37 - - 38 20 - - - SPARE EF-G4 3#6 1#10 1" 80 37 7.5 3.2 38 2 39 2.5 0.8 40 2 SPARE - - - 20 39 - - 40 20 - - - SPARE 39 7.5 3.2 40 3 SPARE - - - 20 41 - - \42 '_v - _ = SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE 3 41 7.5 - 42 20 - - - SPARE 11.9 12.5 9.5 KVA PER PHASE PANEL "2L1'" 3.5 3.5 3.5 KVA PER PHASE 129.0 124.6 126.3 KVA PER PHASE 16.6 11.1 15.8 KVA PER PHASE PANEL "2L2" 12.6 12.6 12.6 AMPS PER PHASE 465.7 449.5 455.9 AMPS PER PHASE 11.8 12.2 12.2 KVA PER PHASE PANEL "2L5" 10.5 TOTAL KVA 379.9 TOTAL KVA 35.8 34.8 33.4 TOTAL KVA PER PHASE 298.3 290.0 278.3 TOTAL AMPS PER PHASE 104.0 TOTAL KVA SCHEDULE OF BRANCH CIRCUIT PANEL "2Br SCHEDULE OF BRANCH CIRCUIT PANEL "2D" SCHEDULE OF BRANCH CIRCUIT PANEL "2L4" MAIN: 200 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT MAIN: 225 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/12OVo 30, 4 WIRE MOUNTING: FLUSH AIC SYMM: 18,000 MOUNTING: FLUSH AIC SYMM: 18,000 Q SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT A PHASE B PHASE C PHASE A PHASE B PHASE C PHASE DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION MOUNTING: FLUSH AIC SYMM: 22,000 KVA KVA KVA KVA KVA KVA � A PHASE 6 PHASE C PHASE BIG ASS FAN 3#12 1#12 1 2 15 1 0.8 0.8 2 15 1 2 1#12 3#12 BIG ASS FAN AIR COMPRESSOR 4#3 0 1#2 -1 2 00 1 44.3 4.2 2 15 1 2 1#12 3#12 REFRIGERATED AIR DRYER o DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION V KVA KVA KVA 3 0.8 0.8 4 3 44.3 4.2 4 RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES 3 5 0.8 0.8 6 3 3 5 44.3 4.2 6 3 DROP CORD POWER #12 #12 1 2 20 3 0.8 0.8 4 20 1 2 #12 #12 DROP CORD POWER BIG ASS FAN 3#12 1#12 1/2" 15 7 0.8 - 8 20 - - - SPARE CNC ROUTER 3#6 1#10 1" 60 7 16.6 16.6 8 60 1" 1#10 3#6 CNC ROUTER DROP CORD POWER #12 #12 1 2" 20 5 0.8 0.8 6 20 1 2" #12 #12 DROP CORD POWER 9 0.8 3.5 10 20 1 2" #12 #12 LIGHTING 9 16.6 16.6 10 Q Q DROP CORD POWER #12 #12 1 2 20 7 0.8 0.8 8 20 1 2 #12 #12 DROP CORD POWER 3 11 0.8 3.5 12 20 1 2 #12 #12 LIGHTING 3 11 16.6 16.6 12 3 1 m M M DROP CORD POWER #12 #12 1 2" 20 9 0.8 0.8 10 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 13 3.5 3.5 14 20 1 2" #12 #12 LIGHTING DUST COLLECTOR 3#6 1#10 1" 65 13 16.6 1.2 20 1 2 #10 3 0 EF- _ DROP CORD POWER #12 #12 1 2" 20 11 0.8 0.8 12 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2 20 15 3.5 - 16 20 - - - SPARE 15 16.6 1.2 16 / U i co U- DROP CORD POWER #12 #12 1 2" 20 13 0.8 0.8 14 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 17 3.5 3.5 18 20 1 2" #12 #12 LIGHTING 3 17 16.6 1.2 8 ; ____ r •� Cn RECEPTACLES #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 RECEPTACLES LIGHTING #12 #12 1 2 20 19 3.5 - 20 20 - - - SPARE EF-S1 3#3 1#8 1-1/4" 19 7.8 1.2 20 25 1 2 3 EF- G1 L DROP CORD POWER #12 #12 1 2 20 17 0.8 0.8 18 20 1 2 #12 #12 DROP CORD POWER SPARE - - - 20 21 - - 22 20 - - - SPARE 21 7.8 1.2 22 a DROP CORD POWER #12 #12 1 2" 20 19 0.8 0.8 20 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2" 20 23 3.5 3.5 24 20 1 2" #12 #12 LIGHTING 23 7.8 1.2 24 3 m o L DROP CORD POWER #12 #12 1 2 20 21 0.8 0.8 22 20 1 2 #12 #12 DROP CORD POWER SPARE - - - 20 25 - 3.5 26 20 1 2 #12 #12 LIGHTING SPARE - - - 20 25 - 1.2 26 25 1 2 1#10 3#10 EF-SPG2 U DROP CORD POWER #12 #12 1 2" 20 23 0.8 0.8 24 20 1 2" #12 #12 DROP CORD POWER SPARE - - - 20 27 - - 28 20 - - - SPARE SPARE - - - 20 27 - 1.2 28 m LL DROP CORD POWER #12 #12 1 2" 20 25 0.8 0.8 26 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2 20 29 3.5 3.5 30 20 1 2 #12 #12 LIGHTING SPARE - - - 20 29 - 1.2 30 3 DROP CORD POWER #12 #12 1 2" 20 27 0.8 0.8 28 20 1 2" #12 #12 DROP CORD POWER SPARE - - - 20 31 - - 32 20 - - - SPARE SPARE - - - 20 31 - - 32 20 - - - SPARE m DROP CORD POWER #12 #12 1 2" 20 29 0.8 1.0 30 20 1 2" #12 #12 DROP CORD POWER LIGHTING #12 #12 1 2 20 33 3.5 3.5 34 20 1 2 #12 #12 LIGHTING SPARE - - - 20 33 - - 34 20 - - - SPARE U RECEPTACLES #12 #12 1 2 20 31 0.8 0.8 32 20 1 2 #12 #12 RECEPTACLES LIGHTING #12 #12 1 2" 20 35 3.5 - 36 20 - - - SPARE SPARE - - - 20 35 - - 36 20 - - - SPARE RECEPTACLES #12 #12 1 2" 20 33 0.8 0.8 34 20 1 2" #12 #12 RECEPTACLES LIGHTING #12 #12 1 2" 20 37 3.5 2.6 38 20 1 2" #12 #12 LIGHTING SPARE - - - 20 37 - - 38 20 - - - SPARE RECEPTACLE #12 #12 1 2 20 35 1.0 1.0 36 20 1 2 #12 #12 RECEPTACLE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE RECEPTACLE #12 #12 1 2" 20 37 1.0 1.0 38 20 1 2" #12 #12 RECEPTACLE SPARE - - - 20 41 - - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE FLOW TAMPER POWER #12 #12 1 2" 20 39 1.2 - 40 20 - - - SPARE 22.5 16.4 30.4 KVA PER PHASE 109.7 109.7 109.7 KVA PER PHASE SPARE - - - 20 41 - - 42 20 - - - SPARE 81.2 59.2 109.7 AMPS PER PHASE 396.0 396.0 396.0 AMPS PER PHASE •� 11.6 10.8 10.2 KVA PER PHASE 69.3 TOTAL KVA 329.1 TOTAL KVA 96.7 90.0 85.0 AMPS PER PHASE 32.6 TOTAL KVA X w SCHEDULE OF BRANCH CIRCUIT PANEL r2L5" SCHEDULE OF BRANCH CIRCUIT PANEL "2L2". SCHEDULE OF BRANCH CIRCUIT PANEL "2G" MAIN: 225 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/12OV, 30, 4 WIRE MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE MAIN: 225 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 208/12OVo 30, 4 WIRE SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT SPEC: SQUARE D TYPE "NQOD" OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 22,000 MOUNTING: FLUSH AIC SYMM: 18,000 MOUNTING: FLUSH AIC SYMM: 22,000 DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION A PHASE B PHASE C PHASE KVA KVA KVA KVA KVA KVA DESCRIPTION WIRE GND. COND. TRIP CKT. CKT. TRIP COND. GND. WIRE DESCRIPTION KVA KVA KVA RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES AIR COMPRESSOR 4#3/0 1#22-1/2' 00 1 44.3 4.2 2 15 1/2" 1#12 3#12 REFRIGERATED AIR DRYER RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES RECEPTACLES #12 #12 1 2" 20 3 0.8 0.8 4 20 1 2" #12 #12 DROP CORD POWER 3 44.3 4.2 4 RECEPTACLES #12 #12 1 2 20 3 0.8 0.8 4 20 1 2 #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2" 20 5 0.8 0.8 6 20 1 2" #12 #12 DROP CORD POWER 3 5 44.3 4.2 6 3 DROP CORD POWER #12 #12 1 2" 20 5 0.8 0.8 6 20 1 2" #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2 20 7 0.8 0.8 8 20 1 2 #12 #12 DROP CORD POWER SITE LIGHTING 2#10 1#10 3/4" 0 7 1.2 1.2 8 2 3/4" 1#10 2#10 SITE LIGHTING DROP CORD POWER #12 #12 1 2" 20 7 0.8 0.8 8 20 1 2" #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2" 20 9 0.8 0.8 10 20 1 2" #12 #12 DROP CORD POWER 2 9 1.2 1.2 10 2 a--� DROP CORD POWER #12 #12 1 2" 20 9 0.8 0.8 10 20 1 2" #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2 20 11 0.8 0.8 12 20 1 2 #12 #12 RECEPTACLES SITE LIGHTING 2#10 1#10 3/4" 0 11 1.2 1.2 12 2 3 4 1#10 2#10 SITE LIGHTING DROP CORD POWER #12 #12 1 2" 20 11 0.8 0.8 12 20 1 2" #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2" 20 13 0.8 0.8 14 20 1 2" #12 #12 DROP CORD POWER 2 13 1.2 1.2 14 2 DROP CORD POWER #12 #12 1 2 20 13 0.8 0.8 14 20 1 2 #12 #12 RECEPTACLES DROP CORD POWER #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 DROP CORD POWER TABLE VACUUMS 3#6 1#8 1" 60 15 18.0 18.0 16 60 1" 1#10 3#6 TABLE VACUUMS m RECEPTACLES #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2" 20 17 0.8 0.8 18 20 1 2" #12 #12 DROP CORD POWER 17 18.0 18.0 18 m DROP CORD POWER #12 #12 1 2 20 17 0.8 0.8 18 20 1 2 #12 #12 DROP CORD POWER DROP CORD POWER #12 #12 1 2" 20 19 0.8 0.8 20 20 1 2" #12 #12 DROP CORD POWER 3 19 18.0 18.0 20 3 m DROP CORD POWER #12 #12 1 2" 20 19 0.8 0.8 20 20 1 2" #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2 20 21 0.8 0.8 22 20 1 2 #12 #12 RECEPTACLES FREIGHT ELEVATOR 3#6 1#8 1" 50 21 4.5 - 22 20 - - - SPARE V DROP CORD POWER #12 #12 1 2" 20 21 0.8 0.8 22 20 1 2" #12 #12 DROP CORD POWER IWH 2#8 1#10 3/4" 4 23 3.3 0.8 24 20 1 2" #12 #12 RECEPTACLES 23 4.5 - 24 20 - - - SPARE •� -j DROP CORD POWER #12 #12 1 2 20 23 0.8 0.8 24 20 1 2" #12 #12 DROP CORD POWER 2 25 3.3 0.8 26 20 1 2 #12 #12 RECEPTACLES 3 25 4.5 - 26 20 - - - SPARE > DROP CORD POWER #12 #12 1 2" 20 25 0.8 0.8 26 20 1 2" #12 #12 DROP CORD POWER RECEPTACLES #12 #12 1 2" 20 27 0.8 0.9 28 20 1 2" #12 #12 DRINKING FOUNTAIN SPARE - - - 20 27 - - 28 20 - - - SPARE DROP CORD POWER #12 #12 1 2 20 27 0.8 0.8 28 20 1 2 #12 #12 DROP CORD POWER RECEPTACLES #12 #12to 1 2" 20 29 0.8 0.8 30 20 1 2" #12 #12 RECEPTACLES SPARE - - - 20 29 - - 30 20 - - - SPARE Z C DROP CORD POWER #12 #12 1 2" 20 29 0.8 1.0 30 20 1 2" #12 #12 RECEPTACLES RECEPTACLES #12 #12 1 2" 20 31 0.8 0.8 32 20 1 2" #12 #12 RECEPTACLES SPARE - - - 20 31 - - 32 20 - - - SPARE c RECEPTACLES #12 #12 1 2 20 31 1.0 0.8 32 20 1 2 #12 #12 RECEPTACLES JIB CRANE #12 #12 1 2" 20 33 1.2 0.8 34 20 1 2" #12 #12 RECEPTACLES SPARE - - - 20 33 - - 34 20 - - - SPARE o RECEPTACLES #12 #12 1 2" 20 33 0.8 1.0 34 20 1 2" #12 #12 GARBAGE DISPOSAL JIB CRANE #12 #12 1 2 20 35 1.2 3.3 36 4 3 4 1#10 2#8 DIP POOL SPARE - - - 20 35 - - 36 20 - - - SPARE RECEPTACLES #12 #12 1 2" 20 35 -- 0.8 36 20 1 2" #12 #12 RECEPTACLES SUMP PUMP #12 #12 1 2" 20 37 1.2 3.3 38 2 SPARE - - - 20 37 - - 38 20 - - - SPARE RECEPTACLE #12 #12 1 2" 20 37 1.0 1.0 38 20 1 2" #12 #12 RECEPTACLE BREATH AIR MACHINE #12 #12 1 2" 20 39 1.0 - 40 20 - - - SPARE DOOR POWER #12 #12 1 2" 20 39 1.2 1.2 40 20 1 2" #12 #12 DOOR POWER RECEPTACLES #12 #12 1 2" 20 41 0.8 - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE DOOR POWER #12 #12 1 2 20 41 1.2 1.2 42 20 1 2 #12 #12 DOOR POWER 16.6 11.1 15.8 KVA PER PHASE 93.8 91.4 91.4 KVA PER PHASE 11.8 12.2 12.2 KVA PER PHASE 138.3 92.5 125.0 AMPS PER PHASE 322.4 313.7 313.7 AMPS PER PHASE 98.3 101.7 101.7 AMPS PER PHASE 43.5 TOTAL KVA 276.6 TOTAL KVA 36.2 TOTAL KVA SCHEDULE OF BRANCH CIRCUIT PANEL "2E" SCHEDULE OF BRANCH CIRCUIT PANEL "2L3". SCHEDULE OF DRY-TYPE TRANSFORMERS MAIN: 225 AMP / 3 POLE MAIN CIRCUIT BREAKER (PROVIDE WITH FEED THRU LUGS) VOLTAGE: 208/12OV, 30, 4 WIRE VOLTAGE SECONDARY FEEDER MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE SPEC: SQUARE D TYPE 'MOD" OR APPROVED EQUIVALENT MARK KVA PRIMARY SECONDARY MOUNTING MARK BREAKER FEEDER NOTES SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 22,000 T1A 75 480 VOLT 208 120 VOLT - T1D-1L O 4#4/0 & 1 2G - MOUNTING: FLUSH AIC SYMM: 18,000 DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION 30,3W 30,4W IN 2-1/2' DESCRIPTION WIRE GND. COND. TRIP CKT. A PHASE B PHASE C PHASE CKT. TRIP COND. GND. WIRE DESCRIPTION KVA KVA KVA - - - - - - - - - KVA KVA KVA RECEPTACLES #12 #12 1 2" 20 1 0.8 0.8 2 20 1 2" #12 #12 RECEPTACLES LIFT STATION 3#12 1#12 1 2 20 1 4.4 4.4 2 20 1 2 1#12 3#12 LIFT STATION DROP CORD POWER #12 #12 1 2 20 3 0.8 0.8 4 20 1 2 #12 #12 DROP CORD POWER 3 4.4 4.4 4 DROP CORD POWER #12 #12 1 2" 20 5 0.8 0.8 6 20 1 2" #12 #12 DROP CORD POWER NOTE: 3 5 4.4 4.4 6 3 DROP CORD POWER #12 #12 1 2" 20 7 0.8 0.8 8 20 1 2" #12 #12 RECEPTACLES O PANEL MAIN BREAKER IS TRANSFORMER SECONDARY BREAKER. CNC ROUTER 3#6 1#10 1" 60 7 16.6 16.6 8 60 1" 1#10 3#6 CNC ROUTER RECEPTACLES #12 #12 1 2" 20 9 0.8 0.8 10 20 1 2" #12 #12 DROP CORD POWER 9 16.6 16.6 10 DROP CORD POWER #12 #12 1 2" 20 11 0.8 0.8 12 20 1 2" #12 #12 DROP CORD POWER 3 11 16.6 16.6 12 3 DROP CORD POWER #12 #12 1 2 20 13 0.8 0.8 14 20 1 2 #12 #12 DROP CORD POWER TABLE VACUUMS 3#6 1#10 1" 60 13 16.6 16.6 14 60 1" 1#10 3#6 TABLE VACUUMS DROP CORD POWER #12 #12 1 2" 20 15 0.8 0.8 16 20 1 2" #12 #12 DROP CORD POWER 15 16.6 16.6 16 DROP CORD POWER #12 #12 1 2 20 17 0.8 0.8 18 26 1 2 #12 #12 DROP CORD POWER 3 17 16.6 16.6 18 3 DROP CORD POWER #12 #12 1 2" 20 19 0.8 0.8 20 20 1 2" #12 #12 RECEPTACLES DUST COLLECTOR 3#6 1#10 1" 65 19 18.0 3.8 20 40 1" 1#10 3#6 GLASS CUTTER RECEPTACLES #12 #12 1 2 20 21 0.8 2.5 22 4 3/4" 1#10 2#8 EWH 21 18.0 3.8 22 RECEPTACLES #12 #12 1 2" 20 23 0.8 2.5 24 2 V► 3 23 18.0 3.8 24 3 RECEPTACLES #12 #12 1 2" 20 25 0.8 0.8 26 20 1 2" #12 #12 RECEPTACLES SPARE - - - 20 25 - - 26 20 - - - SPARE RECEPTACLES #12 #12 1 2 20 27 0.8 0.8 28 20 1 2 #12 #12 RECEPTACLES ai SPARE - - - 20 27 - - 28 20 - - - SPARE RECEPTACLES #12 #12 _1 2" 20 29 0.8 0.8 30 20 1 2" #12 #12 RECEPTACLES E A SPARE - - - 20 29 - - 30 20 - - - SPARE RECEPTACLES #12 #12 1 2 20 31 0.8 0.8 32 20 1 2 #12 #12 RECEPTACLES Z p4 SPARE - - - 20 31 - - 32 20 - - - SPARE RECEPTACLE #12 #12 1 2" 20 33 1.0 1.0 34 20 1 2" #12 #12 RECEPTACLE a� W SPARE - - - rA 20 33 - - 34 20 - - - SPARE FUTURE 1-TON BRIDGE CRANE 2#10 1#10 3 4 3 35 2.0 1.0 36 20 1 2 #12 #12 RECEPTACLE SPARE - - - 20 35 - - 36 20 - - - SPARE 2 37 2.0 1.0 38 20 1 2" #12 #12 RECEPTACLE Ali SPARE - - - 20 37 - - 38 20 - - - SPARE RESIN SYSTEM 2#10 1#10 3/4" 3 39 2.4 - 40 20 - - - SPARE p SPARE - - - 20 39 - - 40 20 - - - SPARE 2 41 2.4 - 42 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE 12.6 14.1 15.1 KVA PER PHASE PANEL "2L3" 93.2 93.2 93.2 KVA PER PHASE 11.6 10.8 10.2 KVA PER PHASE PANEL "2L4" 336.5 336.5 336.5 AMPS PER PHASE 24.2 24.9 25.3 TOTAL KVA PER PHASE 279.6 TOTAL KVA 185.0 207.5 194.2 TOTAL AMPS PER PHASE 74.4 TOTAL KVA o Lo Digitally signed by Bradly ISSUED FOR PERMIT ONLY 05-07-21 o N Bradly L Brown P.E. NOT FOR PRICING OR CONSTRUCITON N Cfl N � D N: c n=B ra d l y L Brown n KAMM CONSULTING PROJECT#: 2020-0562 E PROJECT MANAGER: JOHN MAYR Z Qj P.E., o=Kamm Consulting z Brown _ MM 1408 Orange Avenue a)Inc. ou-FL# 58232 Fort Pierce,Florida 34950 Phone 954.448.0792 email='mar ka m m co n s *; a_ --- jmayr@kammconsuhing.com y @ n9 Certification of Authorization#8189 ulting.Com, C=US PRINCIPAL 06-21-21 Date: 2021 .06.21 Bradly L Brown Florida License#58232 date POE * 12:29:12 -04'00' signed