Loading...
HomeMy WebLinkAbout2020-0562E6-1-E6-1 SCHEDULE OF BRANCH CIRCUIT PANEL 772F" N m - � L mo3 MAIN: 400 AMP / 3 POLE MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE `°" m 0 76 SPEC: SQUARE D TYPE "NF" OR APPROVED EQUIVALENT MOUNTING: FLUSH AIC SYMM: 18,000 m� A PHASE B PHASE C PHASE 3 ''L DESCRIPTION WIRE GND. COND. TRIP CKT. KVA KVA KVA CKT. TRIP COND. GND. WIRE DESCRIPTION g c SPARE - - - 20 1 - - 2 20 - - - SPARE SPARE - - - 20 3 - - 4 20 - - - SPARE _ `" LU SPARE - - - 20 5 - - 6 20 - - - SPARE U)y p m a SPARE - - - 20 7 - - 8 20 - - - SPARE N m m SPARE - - - 20 9 - - 10 20 - - - SPARE _ o z SPARE - - - 20 11 - - 12 20 - - - SPARE a' - O LL s? � SPARE - - - 20 13 - - 14 20 - - - SPARE 2i T L s t U o SPARE - - - 20 15 - - 16 20 - - - SPARE `� SPARE - - - 20 17 - - 18 20 - - - SPARE c 0 a s s SPARE - - - 20 19 - - 20 20 - - - SPARE SPARE - - - 20 21 - - 22 20 - - - SPARE L Q N M V CO I� SPARE - - - 20 23 - - 24 20 - - - SPARE Q m m _ SPARE - - - 20 25 - - 26 20 - - - SPARE z O SPARE - - - 20 27 - - 28 20 - - - SPARE O SPARE - - - 20 29 - - 30 20 - - - SPARE SPARE - - - 20 31 - - 32 20 - - - SPARE SPARE - - - 20 33 - - 341 20 - - - ISPARE U SPARE - - - 20 35 - - 36 20 - - - SPARE SPARE - - - 20 37 - - 38 20 - - - SPARE SPARE - - - 20 39 - - 40 20 - - - SPARE SPARE - - - 20 41 - - 42 20 - - - SPARE 98.3 98.3 98.3 KVA PER PHASE U) 354.9 354.9 354.9 AMPS PER PHASE 294.9 TOTAL KVA z O CU SCHEDULE OF DISTRIBUTION PANEL "MDP1" o 101 Lj- U) MAIN: 1200 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 O DESIGNATION DESCRIPTION CIRCUIT BREAKER FEEDER A PHASE B PHASE C PHASE NOTES FRAME TRIP POLES KVA KVA KVA z MDP1-1 PANEL 2A - 100 3 4 & 1 - 1-1 3.5 3.5 3.5 MDP1-2 PANEL 2B - 200 3 4J64U & 1#2G - - 22.5 16.4 30.4 MDP1-3 PANEL 2C - 600 3 2 SEIS - 4-6bUMUM & 1#1G - 129.0 124.6 126.3 MDP1-4 DCF-SP1 - 70 3 3 4 & 1 8G IN 1-1/4" 16.0 16.0 16.0 w MDP1-5 PANELS "213 & 214" VIA XFMR - 110 3 4- 4 0 & 1#2G IN 2-1 2" 10.6 14.1 13.1 U) MDP1-6 RALI-G1 - 100 3 3 3 & 1 8G IN 1-1/4- 18.0 18.0 18.0 MDP1-7 DCF-H1 - 70 3 3 4 & 1 8G IN 1-1 4" 18.8 18.8 18.8 MDP1-8 DCF-D1 - 70 3 3 4 & 1 8G IN 1-1/4- 18.8 18.8 18.8 ~ `J MDP1-9 GEL BOOTH - 60 3 3#6 & 1#10G IN 1-1/4" 16.0 16.0 16.0 MDPl-10 GEL BOOTH - 60 3 3#6 & 1 10G IN 1-1 4 16.0 16.0 16.0 MDPl-11 WEST SIDE COMPACTOR - 3 3 6 & 1 10G IN 1-1/4- 2.2 2.2 2.2 w MDPl-12 TVSS - 30 1 1 10 & 1 10G - 3 4 2.9 - - ^ MDPl-13 PANEL 2F - 400 3 4-500MCM & 1 3G - 4 - - - 0- Q w MDPl-14 PANEL 2G - 400 3 4-500MCM & 1 3G - 4 93.8 91.4 91.4 1 O MDPl-15 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1 0.9 0.9 0.9 MDPl-16 SPARE - - - - - - - MDP1-17 SPARE - - - - - - - N O00 MDPl-18 SPARE - - - - - - - C °t c9 � o MDPl-19 - - - - - - - - CV m � cai MDPl-20 - - - - - - - - rr l� 304.6 294.7 309.9 KVA PER PHASE W M 1081.9 1046.2 1169.3 AMPS PER PHASE Ln Q x 909.2 TOTAL KVA C [� U m Z ' LL M-�-I 00 m SCHEDULE OF DISTRIBUTION PANEL "MDP2" w Q o 0 MAIN: 1200 AMP / 3 POLE, MAIN CIRCUIT BREAKER VOLTAGE: 480/277V, 30, 4 WIRE Z u1 ti SPEC: SQUARE D OR APPROVED EQUIVALENT AIC SYMM: 65,000 LL cn CIRCUIT BREAKER A PHASE B PHASE C PHASE Q �j m oN H DESIGNATION DESCRIPTION FRAME TRIP POLES FEEDER KVA KVA KVA NOTES MDP2-1 SPARE - 250 3 3-250MCM & 1 4G - 3 34.6 34.6 34.6 MDP2-2 DEKKER - 70 3 3 #3 & 1 8G - 1-1 2 9.4 9.4 9.4 MDP2-3 AIR DRYER - 30 3 3- 10 & 1 10G - 3 4 8.3 8.3 8.3 MDP2-4 PANELS 21-1,21-2,&21-5 VIA XFM - 110 3 4-#4 0 & 1#2G IN 2-1 2 31.5 29.1 31.5 MDP2-5 HOIST - 90 3 3 3 & 1 8G - 1-1 4 15.0 15.0 15.0 MDP2-6 HOIST - 90 3 3 3 & 1 8G - 1-1/4" 15.0 15.0 15.0 MDP2-7 HOIST - 90 3 3 3 & 1 8G - 1-1/4" 15.0 15.0 15.0 MDP2-8 BRIDGE CRANE - 60 3 3#6 & 1 10G IN 1-1 4 16.0 16.0 16.0 MDP2-9 PANEL 2D - 400 3 4-500MCM & 1 3G - 4 109.7 109.7 109.7 MDP2-10 GRIND BOOTH - 60 3 3#6 & 1 10G IN 1-1/4" 16.0 16.0 16.0 MDP2-11 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1" 0.9 0.9 0.9 MDP2-12 TVSS - 30 1 1 10 & 1 10G - 3 4 2.9 - - MDP2-13 BIG ASS FAN - 20 3 3#12 & 1#12G IN 1 0.9 0.9 0.9 MDP2-14 DEKKER - 70 3 3 #3 & 1 8G - 1-1 2 9.4 9.4 9.4 MDP2-15 - - - - - - - - MDP2-16 - - - - - - - - MDP2-17 - - - - - - - - MDP2-18 - MDP2-19 BIG ASS FAN - 20 3 3 12 & 1 12G IN 1 0.9 0.9 0.9 MDP2-20 - - - - - - - - Q MDP2-21 - - - - - - - - 287.3 282.0 284.4 KVA PER PHASE L! 1037.2 1018.1 1026.7 1 AMPS PER PHASE J 853.7 ITOTAL KVA 0 O 0 rn W Cl) M J U i LL N � L (6 a � U oL m L.L C N U C .U) Ca Q X LU Q� U) A C rL V m C m -> � m C) U E > C/7 Z U t U � O d a A A w x E m a Z 0 z a 0 0 Ln 0 CD Digitally signed by Bradly L ISSUED FOR PERMIT ONLY 05-07-21 0 0 BraL Brown P.E. NOT FOR PRICING OR CONSTRUCITON N Cfl DN: cn=Bradly L Brown P.E., KAMM CONSULTING PROJECT#: 2020-0562 E PROJECT MANAGER: JOHN MAYR Z Qj o=Kamm Consulting Inc., z �� 1408 Orange Avenue "o w n ou=FL# 58232, Fort Pierce,Florida 34950 o Phone 954.448.0792 = � - ma i-&kammconsultin com U) � a_ email=�mayr@kammconsult onsu ng lokAmm *certrficationofAuthorgation#8189 ing.com, c=US PRINCIPAL 06-21-21 POE * Date: 2021 .06.21 1 2:28:39 Bradly L Brown Florida License#58232 date -04'00 signed