Maverick Boat Group Inc — Phase II Expansion
Responses to Review comments
May 26, 2021
Permit Number.: 2105-0262
Record Type: BUILDING COMMERCIAL
Parcel NBR: 1431-120-0000-000/6
Address: 4551 St Lucie Blvd
Fort Pierce, FI 34946
Contractor: Richard K Davis Construction Corp.
4205 Metzger Road
Fort Pierce, FL 34947
Phone: 772-461-8335
Fax: 772-465-7665
REVIEWS & COMMENTS
DOCUMENTS MISSING PENDING Karen Nielsen
DATE: 05/10/2021
COMMENT:
RECORDED NOC.
RESPONSE:
GC to provide Notice of Commencement.
DATE: 05/10/2021
COMMENT:
SUB-CONTRACTOR AGREEMENTS
RESPONSE:
GC to provide Sub-Contractor agreements.
20 SE OCEAN BLVD. STUART, FLORIDA 34996
772.220.1217 brentgbawoodarch.com fax772.419.5061
IF
BRENT A WOOD
ARCH ITECTU RE
DATE: 05/10/2021
COMMENT:
BLUEBEAM
RESPONSE:
DATE: 05/10/2021
COMMENT:
NO BUILDING PERMITS FOR ANY VERTICAL CONSTRUCTION WILL BE
ISSUED UNTIL THE REQUIRED OFFSITE IMPROVEMENTS HAVE BEEN
REVIEWED, PERMITTED, AND THE ROADWAY IMPROVEMENT
AGREEMENT AND BOND HAVE BEEN EXECUTED. ADDITIONALLY, NO
FORM OF CO WILL BE SUPPORTED FOR PHASE 2 UNTIL ALL OFFSITE
IMPROVEMENTS HAVE BEEN COMPLETED, INSPECTED, AND ACCEPTED
BY THE COUNTY
RESPONSE:
Noted
ENGINEERING DEPARTMENT PENDING Grant Chambers
COMMENT:
ENVIRONMENTAL REVIEW PENDING Aimee Cooper
COMMENT:
FIRE DEPARTMENT REVIEW PENDING Tony Jerger
COMMENT:
FRONT COUNTER REVIEW COMPLETE Karen Nielsen
DATE: 5/10/2021
COMMENT:
NOTIFIED FOR PICK UP PENDING
COMMENT:
20 SE OCEAN BLVD. STUART, FLORIDA 34996
772.220.1217 brentkbawoodarch.com fax772.419.5061
IF
BRENT A WOOD
ARCH ITECTU RE
PLANNING REVIEW PENDING
COMMENT:
PLANS EXAMINER ELECTRIC PENDING Doug Harvey
COMMENT:
PLANS EXAMINER ELECTRIC PENDING Walter Pride
DATE: 5/15/2021
COMMENT:
PLANS EXAMINER MECHANICAL INCOMPLETE Mike Halter
DATE: 5/14/2021
COMMENT:
SUBMITTED MECHANICAL PLAN SET IS INCOMPLETE; PLEASE ADDRESS
MECHANICAL FBC 7TH EDITION, 2020 CHAPTERS 4, 5 AND 6
REQUIREMENTS AND INCLUDE FAN SCHEDULES, AIR CONDITIONING
SPLIT SYSTEM EQUIPMENT SCHEDULE, OUTSIDE AIR CALCULATIONS,
INTAKE & EXHAUST FAN DETAIL, AND GEL AND GRIND BOOTH
MECHANICAL DETAIL ETC., PER 107.2 OF THE FBC 7TH EDITION, 2020.
RESPONSE:
Please refer to mechanical sheets M0.1, M2.1 & M2.1.1 for mechanical
information on A/C split system for non-habitable electric room space.
Ventilation design and required calculations / schedules for intake and
exhaust of equipment and Gel / Grinding booths shall be defined and
provided by a specialty industrial ventilation consultant and will be a
defined in manufacturer shop drawings.
We respectfully request the ventilation data be considered as a "Deferred
Submittal" and tied to a milestone inspection as a condition of approval,
but not hold up issuance of the building permit.
PLANS EXAMINER PLUMBING PENDING Andy Wentz
DATE: 5/12/2021
20 SE OCEAN BLVD. STUART, FLORIDA 34996
772.220.1217 brentgbawoodarch.com fax772.419.5061
IF
BRENT A WOOD
ARCH ITECTU RE
COMMENT:
PLANS EXAMINER REVIEW PENDING Jpi, Inc-Andrew
DATE: 5/12/2021
METAL BUILDING
COMMENT:
PRODUCT APPROVALS- PLEASE CHECK AGAINST THE
ARCHITECTURAL DRAWINGS, THERE ARE MULTIPLE CONFLICTS
BETWEEN COMPONENTS AND CLADDING ON THE ARCHITECTURAL
AND THE VULCAN DRAWINGS.
ALSO NOTE, MULTIPLE PRODUCT APPROVAL NUMBERS ON THE
VULCAN DRAWINGS SHOW- THERE ARE NO RECORDS THAT
MATCH THE SEARCH CRITERIA. ([A]107.2.1)
RESPONSE:
Please refer to the revised cover sheet CV-1; Product Approval Checklist
for corrected product approvals received from the building manufacturer.
Architectural drawings referencing metal building components were
prepared using approvals provided by Vulcan Steel Structures
representative.
Architect has verified the approvals listed on Product Approval Checklist
on sheet CV-1 are valid & current on the Florida DBPR Product Approval
website.
DATE: 5/18/2021
ARCHITECTURAL
COMMENT:
3. CLARIFY CONSTRUCTION TYPE ON THE PLANS, COVER SHEET
STATES THIS IS TYPE IB. (602.1)
RESPONSE:
Proposed construction type to match existing building; Type II-B
Please refer to the revised construction type in the Project Data table on
cover sheet CV-1.
20 SE OCEAN BLVD. STUART, FLORIDA 34996
772.220.1217 brentgbawoodarch.com fax772.419.5061
IF
BRENT A WOOD
ARCH ITECTU RE
DATE: 5/19/2021
COMMENT:
4. PLEASE CLARIFY THE DISTANCE OF THE BUILDING TO THE
PROPERTY LINE-ARCHITECTURAL SHEET A1.00 AND CIVIL SHEET
C-2. PLEASE CLEARLY LABEL THE PROPERTY LINE ON ALL
DRAWINGS.
THE DISTANCE WILL AFFECT THE UNLIMITED ALLOWABLE
BUILDING AREA, IN SECTION 507.4 OF THE FLORIDA BUILDING
CODE.
SPOKE WITH ERIC IRELAND FROM ARCHITECT'S OFFICE ON 5/14/21
TO CLARIFY.
RESPONSE:
Please refer to the revised architectural Site Plan A-1.00 for corrected &
coordinated Property Line and Right of Way designations and clarification
dimensions.
This project qualifies as an Unlimited Area Building using the entire width
of the "Public Way" for measurement of Open Space which is defined
under section 507 of the FBC 2020, Seventh Edition.
DATE: 5/19/2021
COMMENT:
5. PLEASE PROVIDE THE DESIGN & DETAILS FOR THE RESTROOMS-
FRAMING DETAILS FOR THE WALLS AND CEILING OF THE
RESTROOM, DIMENSIONS, ACCESSORY MOUNTING. ([A]107.2.1)
RESPONSE:
Restrooms are not included in proposed scope — Restrooms are intended
for a future phase of construction and are indicated for rough plumbing
stub-outs in the proposed slab / foundations.
Future bathrooms shall be under separate permit applied for subsequent to
C.O. of proposed building permit.
DATE: 5/19/2021
20 SE OCEAN BLVD. STUART, FLORIDA 34996
772.220.1217 brentgbawoodarch.com fax772.419.5061
IF
BRENT A WOOD
ARCH ITECTU RE
COMMENT:
6. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY
ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF
THE FOLLOWING AREAS- PUBLIC RESTROOMS WITH AN AREA
GREATER THAN 300 SQUARE FEET. (1008.3.3)
RESPONSE:
Restrooms are not included in proposed scope — Restrooms are for a
future phase of construction and shall include code compliant emergency
illumination.
Future bathrooms and required lighting shall be under separate permit
applied for subsequent to C.O. of proposed building permit.
DATE: 5/19/2021
COMMENT:
7. EXIT SIGNS ARE SPACED GREATER THAN 100' APART. (1013.1)
RESPONSE:
Please refer to revised Life Safety Plans LS-1.11 & LS-1.12 for revised
compliant emergency lighting layout.
DATE: 5/19/2021
COMMENT:
8. THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A
DOOR. IT IS UNCLEAR IF THERE IS A LANDING OUTSIDE OF THE
EXIT DOORS. (1009.1)
RESPONSE:
A 5'x5' concrete pad, flush with slab level has been added outside of
egress doors on North side of proposed building. Please refer to revised
floor plan A-1.11 for quantities & locations.
DATE: 5/19/2021
COMMENT:
9. PLEASE SHOW THE MEANS OF EGRESS FROM THE MEZZANINE.
(1011.1)
20 SE OCEAN BLVD. STUART, FLORIDA 34996
772.220.1217 brentgbawoodarch.com fax772.419.5061
IF
BRENT A WOOD
ARCH ITECTU RE
RESPONSE:
Future Mezzanine is not included in proposed scope of work — Provisions
for foundations have been included in current permitted slab & foundation
work for future phase of construction.
Mezzanine structure, design, life safety systems and means of egress shall
be under separate permit applied for subsequent to C.O. of proposed
building permit.
DATE: 5/19/2021
STRUCTURAL
COMMENT:
10.ENGINEER'S DIGITAL SIGNATURE IS NOT CERTIFIED. ([A]107)
RESPONSE:
Please refer to structural drawings for issued foundation permit— digital
signature is already on file for proposed structural drawings.
Structural set was included as part of this proposed building permit
submittal for coordination with full building drawings and for informational
purposes for plan review.
DATE: 5/19/2021
COMMENT:
11.COORDINATE FOUNDATION CHANGES WITH FOUNDATION PERMIT.
([A]107.2.1)
RESPONSE:
Please refer to revised, digitally signed foundation drawings.
DATE: 5/19/2021
COMMENT:
12.LOADING DOCK APRON BY OTHERS, PLEASE PROVIDE THE
DESIGN FOR THE APRON. ([A]107.2.1)
RESPONSE:
Please refer to Civil drawings (Under review with SLC Planning & Zoning),
sheets C-3: Phase IB Paving, Grading, Drainage, Utility Plan & C-4: Phase
20 SE OCEAN BLVD. STUART, FLORIDA 34996
772.220.1217 brentgbawoodarch.com fax772.419.5061
IF
BRENT A WOOD
ARCH ITECTU RE
IB Miscellaneous Details for Apron Paving Design by Civil Engineer of
Record.
WATER QUALITY REVIEW PENDING Grant Chambers
COMMENT:
ZONING REVIEW COMPLETE Lydia Galbraith
DATE: 5/10/2021
COMMENT: