Loading...
HomeMy WebLinkAbout2105-0262 Maverick Boats PLANS REVIEW COMMENT Responses 06-01-21 IF BRENT A WOOD ARCH ITECTU RE St. Lucie County Building & Code Regulation Division 2300 Virginia Ave. Fort Pierce, FL. 34982 Maverick Boat Group Inc — Phase II Expansion Responses to Review comments May 26, 2021 Permit Number.: 2105-0262 Record Type: BUILDING COMMERCIAL Parcel NBR: 1431-120-0000-000/6 Address: 4551 St Lucie Blvd Fort Pierce, FI 34946 Contractor: Richard K Davis Construction Corp. 4205 Metzger Road Fort Pierce, FL 34947 Phone: 772-461-8335 Fax: 772-465-7665 REVIEWS & COMMENTS DOCUMENTS MISSING PENDING Karen Nielsen DATE: 05/10/2021 COMMENT: RECORDED NOC. RESPONSE: GC to provide Notice of Commencement. DATE: 05/10/2021 COMMENT: SUB-CONTRACTOR AGREEMENTS RESPONSE: GC to provide Sub-Contractor agreements. 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 IF BRENT A WOOD ARCH ITECTU RE DATE: 05/10/2021 COMMENT: BLUEBEAM RESPONSE: DATE: 05/10/2021 COMMENT: NO BUILDING PERMITS FOR ANY VERTICAL CONSTRUCTION WILL BE ISSUED UNTIL THE REQUIRED OFFSITE IMPROVEMENTS HAVE BEEN REVIEWED, PERMITTED, AND THE ROADWAY IMPROVEMENT AGREEMENT AND BOND HAVE BEEN EXECUTED. ADDITIONALLY, NO FORM OF CO WILL BE SUPPORTED FOR PHASE 2 UNTIL ALL OFFSITE IMPROVEMENTS HAVE BEEN COMPLETED, INSPECTED, AND ACCEPTED BY THE COUNTY RESPONSE: Noted ENGINEERING DEPARTMENT PENDING Grant Chambers COMMENT: ENVIRONMENTAL REVIEW PENDING Aimee Cooper COMMENT: FIRE DEPARTMENT REVIEW PENDING Tony Jerger COMMENT: FRONT COUNTER REVIEW COMPLETE Karen Nielsen DATE: 5/10/2021 COMMENT: NOTIFIED FOR PICK UP PENDING COMMENT: 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentkbawoodarch.com fax772.419.5061 IF BRENT A WOOD ARCH ITECTU RE PLANNING REVIEW PENDING COMMENT: PLANS EXAMINER ELECTRIC PENDING Doug Harvey COMMENT: PLANS EXAMINER ELECTRIC PENDING Walter Pride DATE: 5/15/2021 COMMENT: PLANS EXAMINER MECHANICAL INCOMPLETE Mike Halter DATE: 5/14/2021 COMMENT: SUBMITTED MECHANICAL PLAN SET IS INCOMPLETE; PLEASE ADDRESS MECHANICAL FBC 7TH EDITION, 2020 CHAPTERS 4, 5 AND 6 REQUIREMENTS AND INCLUDE FAN SCHEDULES, AIR CONDITIONING SPLIT SYSTEM EQUIPMENT SCHEDULE, OUTSIDE AIR CALCULATIONS, INTAKE & EXHAUST FAN DETAIL, AND GEL AND GRIND BOOTH MECHANICAL DETAIL ETC., PER 107.2 OF THE FBC 7TH EDITION, 2020. RESPONSE: Please refer to mechanical sheets M0.1, M2.1 & M2.1.1 for mechanical information on A/C split system for non-habitable electric room space. Ventilation design and required calculations / schedules for intake and exhaust of equipment and Gel / Grinding booths shall be defined and provided by a specialty industrial ventilation consultant and will be a defined in manufacturer shop drawings. We respectfully request the ventilation data be considered as a "Deferred Submittal" and tied to a milestone inspection as a condition of approval, but not hold up issuance of the building permit. PLANS EXAMINER PLUMBING PENDING Andy Wentz DATE: 5/12/2021 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 IF BRENT A WOOD ARCH ITECTU RE COMMENT: PLANS EXAMINER REVIEW PENDING Jpi, Inc-Andrew DATE: 5/12/2021 METAL BUILDING COMMENT: PRODUCT APPROVALS- PLEASE CHECK AGAINST THE ARCHITECTURAL DRAWINGS, THERE ARE MULTIPLE CONFLICTS BETWEEN COMPONENTS AND CLADDING ON THE ARCHITECTURAL AND THE VULCAN DRAWINGS. ALSO NOTE, MULTIPLE PRODUCT APPROVAL NUMBERS ON THE VULCAN DRAWINGS SHOW- THERE ARE NO RECORDS THAT MATCH THE SEARCH CRITERIA. ([A]107.2.1) RESPONSE: Please refer to the revised cover sheet CV-1; Product Approval Checklist for corrected product approvals received from the building manufacturer. Architectural drawings referencing metal building components were prepared using approvals provided by Vulcan Steel Structures representative. Architect has verified the approvals listed on Product Approval Checklist on sheet CV-1 are valid & current on the Florida DBPR Product Approval website. DATE: 5/18/2021 ARCHITECTURAL COMMENT: 3. CLARIFY CONSTRUCTION TYPE ON THE PLANS, COVER SHEET STATES THIS IS TYPE IB. (602.1) RESPONSE: Proposed construction type to match existing building; Type II-B Please refer to the revised construction type in the Project Data table on cover sheet CV-1. 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 IF BRENT A WOOD ARCH ITECTU RE DATE: 5/19/2021 COMMENT: 4. PLEASE CLARIFY THE DISTANCE OF THE BUILDING TO THE PROPERTY LINE-ARCHITECTURAL SHEET A1.00 AND CIVIL SHEET C-2. PLEASE CLEARLY LABEL THE PROPERTY LINE ON ALL DRAWINGS. THE DISTANCE WILL AFFECT THE UNLIMITED ALLOWABLE BUILDING AREA, IN SECTION 507.4 OF THE FLORIDA BUILDING CODE. SPOKE WITH ERIC IRELAND FROM ARCHITECT'S OFFICE ON 5/14/21 TO CLARIFY. RESPONSE: Please refer to the revised architectural Site Plan A-1.00 for corrected & coordinated Property Line and Right of Way designations and clarification dimensions. This project qualifies as an Unlimited Area Building using the entire width of the "Public Way" for measurement of Open Space which is defined under section 507 of the FBC 2020, Seventh Edition. DATE: 5/19/2021 COMMENT: 5. PLEASE PROVIDE THE DESIGN & DETAILS FOR THE RESTROOMS- FRAMING DETAILS FOR THE WALLS AND CEILING OF THE RESTROOM, DIMENSIONS, ACCESSORY MOUNTING. ([A]107.2.1) RESPONSE: Restrooms are not included in proposed scope — Restrooms are intended for a future phase of construction and are indicated for rough plumbing stub-outs in the proposed slab / foundations. Future bathrooms shall be under separate permit applied for subsequent to C.O. of proposed building permit. DATE: 5/19/2021 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 IF BRENT A WOOD ARCH ITECTU RE COMMENT: 6. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS- PUBLIC RESTROOMS WITH AN AREA GREATER THAN 300 SQUARE FEET. (1008.3.3) RESPONSE: Restrooms are not included in proposed scope — Restrooms are for a future phase of construction and shall include code compliant emergency illumination. Future bathrooms and required lighting shall be under separate permit applied for subsequent to C.O. of proposed building permit. DATE: 5/19/2021 COMMENT: 7. EXIT SIGNS ARE SPACED GREATER THAN 100' APART. (1013.1) RESPONSE: Please refer to revised Life Safety Plans LS-1.11 & LS-1.12 for revised compliant emergency lighting layout. DATE: 5/19/2021 COMMENT: 8. THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR. IT IS UNCLEAR IF THERE IS A LANDING OUTSIDE OF THE EXIT DOORS. (1009.1) RESPONSE: A 5'x5' concrete pad, flush with slab level has been added outside of egress doors on North side of proposed building. Please refer to revised floor plan A-1.11 for quantities & locations. DATE: 5/19/2021 COMMENT: 9. PLEASE SHOW THE MEANS OF EGRESS FROM THE MEZZANINE. (1011.1) 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 IF BRENT A WOOD ARCH ITECTU RE RESPONSE: Future Mezzanine is not included in proposed scope of work — Provisions for foundations have been included in current permitted slab & foundation work for future phase of construction. Mezzanine structure, design, life safety systems and means of egress shall be under separate permit applied for subsequent to C.O. of proposed building permit. DATE: 5/19/2021 STRUCTURAL COMMENT: 10.ENGINEER'S DIGITAL SIGNATURE IS NOT CERTIFIED. ([A]107) RESPONSE: Please refer to structural drawings for issued foundation permit— digital signature is already on file for proposed structural drawings. Structural set was included as part of this proposed building permit submittal for coordination with full building drawings and for informational purposes for plan review. DATE: 5/19/2021 COMMENT: 11.COORDINATE FOUNDATION CHANGES WITH FOUNDATION PERMIT. ([A]107.2.1) RESPONSE: Please refer to revised, digitally signed foundation drawings. DATE: 5/19/2021 COMMENT: 12.LOADING DOCK APRON BY OTHERS, PLEASE PROVIDE THE DESIGN FOR THE APRON. ([A]107.2.1) RESPONSE: Please refer to Civil drawings (Under review with SLC Planning & Zoning), sheets C-3: Phase IB Paving, Grading, Drainage, Utility Plan & C-4: Phase 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061 IF BRENT A WOOD ARCH ITECTU RE IB Miscellaneous Details for Apron Paving Design by Civil Engineer of Record. WATER QUALITY REVIEW PENDING Grant Chambers COMMENT: ZONING REVIEW COMPLETE Lydia Galbraith DATE: 5/10/2021 COMMENT: 20 SE OCEAN BLVD. STUART, FLORIDA 34996 772.220.1217 brentgbawoodarch.com fax772.419.5061