Loading...
HomeMy WebLinkAboutS S5_01 Sections & Details - Maverick - Rev 2 16 ° ? Ly r ° O N 2 Cn N N a s O N O O m o M N -ItLo N m O Q O O L U —_ O N O Q d U o E_ a Y � m ai E E a d ° o Co Cn rn d @ w `o 0 o m 0 -mo C Q o > LL w a z U o`� a L O o' s o y� L) cn w i1i z o y m > m� m of o cu m w o a L - o Z O `O 1 U BASE CHANNEL BY BLDG. MFR. /WALL PANEL \ I BY BLDG. MFR. I z EL. 8'-8" I U T.O. TB-1 LH co (BB-1) 8"x16" L.L `� II .. MASONRY BOND BEAM a) ui I SEE SECTION 1/S3.01 FOR /J GIRT REQUIREMENTS & Q LINTEL OVER MAN DOORS, TYPICAL BASE PLATE FOOTINGS METAL BLDG COLUMN BY METAL BLDG. MFR. II Cf) Q — W (MW-1) 8" CMU WALL (4) ANCHOR BOLTS x 48" LONG, C 0 (SEE METAL BLDG. DGS. FOR BOLT G 30" MINIMUM LAP DIAMETER & SPACING, TYPICAL) o 00C.0 BASE PLATE BY 0') Co Lo 1'-4" METAL BLDG. MFR. Q LL COORDINATE DIMENSIONS WITH � w METAL BUILDING MANUFACTURER, 0, cor- M � TYPICAL 4" THREADED (1) #7 HAIRPIN BARS PROJECTION 6" THICK CONC. SLAB, U m III 1 1/2" (SEE PLAN) CN I--I Q -0 i �I EL. 0'-0" 00 M-�-I O m N ° T.O. SLAB O � l � o X. co (MATCH EXISTING) I �.J N d •° ° V TS28.24 THICKENED \ \ I ° • ° °P . I ,°° ,° //\//\//\//\//\//\//\//\//\//\//�/ ' z wti SLAB EDGE j\\ a I d, • r° \%\\\\\\�\\�\\�\�\\�\�\�\�\� / I CO C14 w vi L I T.O. PIER j\ • �_— d /\\ (P-1) 24"x24" CONC. PIER, \ _ &—— EXTEND VERTICAL REINFORCING INTO TS28.24 \ \/\ ___ \/\/\/\/\y A . . . A . ° ° ° • ° 3/4" x 10" x 10" PLATE, TYP. d d d a d ° a ° °°• ° d ° a ° d, (4) #6 x 36" LONG ° ° 6 O.C. \ <« ° ° d° ,° m ° a ° "° " �• ° ° °° °d • .g \ (4) #6 x 36" LONG � ` 4. °a •°• d° °`° •° ,•• ° n° . d �� 6' Q.C. 3 5 �--� 9) d \\ ° a • • d °° ° • • •d° • ° • d° ° • ° ° d d °d ° \ (4) #6 x 6'-8" LONG 5'_4��} Q F ° d ° • °° a •I. •d °° • ° ° d ° • • ° \\j ® 6" O.C. BASE CHANNEL ARCHCLO& POOL EENGINEER m M_ M o \\ • ° 4. • ° °\\j BY BLDG. MFR. V i c6 LL AI ° ai 2' 0" BY BLDG. MFR. a 3" CLR (TYP) F6080 OR F8080 FOOTING, I I O -t 2'-0" 4'-0" 2'-0" (SEE PLAN) I EL. 8'-8" I U T.O. TB-1LD I M c HELICAL PILE 8>_p» I (BB-1) 8"x16" I U I MASONRY BOND BEAM I x 6'-0" OR 8'-0" WIDE (SEE PLAN FOR LOCATIONS) D \ O — - - - - - - �(n 4 SECTION 2'-61/2"t 5.0 Scale: 3/4"=1'-0" COORDINATE W/ SEE SECTION 1/S3.01 FOR Q ARCH'L & POOL ENGINEER GIRT REQUIREMENTS & X LINTEL OVER MAN DOORS, w BASE PLATE TYPICAL — � FOOTINGS � BASE PLATE Q FOOTINGS METAL BLDG COLUMN METAL BLDG COLUMN TOP BE DETERMINED z BY METAL BLDG. MFR. BY METAL BLDG. MFR. BY POOL ENGINEER � 0 (4) ANCHOR BOLTS x 8" LONG, 3UT (SEE MTL. BLDG. MFR. DRAWINGS _ LEAVE—OUT OF SLAB ' Q Q (MW-1) 8" CMU WALL (4) ANCHOR BOLTS x 42" LONG, O Q FOR DIAMETER & SPACING) (SEE METAL BLDG. DGS. FOR BOLT 1 30" MINIMUM LAP ) L DIAMETER & SPACING, TYPICAL BASE PLATE BY U' BASE PLATE BY METAL LDG. MFR. 1'-0 1/2" METAL BLDG. MFR. (1) #7 HAIRPIN BAR, HOOK �, z 6" THICK CONC. SLAB, COORDINATE DIMENSIONS WITH INTO T.E. THIS LOCATION ONLY (� TOP BE DETERMINED TOP BE DETERMINED O BY POOL ENGINEER BY POOL ENGINEER 4" THREADED (SEE FOUNDATION PLAN DWG. S1.01) METAL BUILDING MANUFACTURER, 11" 6" THICK CONC. SLAB, — -0 rn 6" THICK CONC. SLAB, PROJECTION TYPICAL 4" THREADED m ! It (SEE FOUNDATION PLAN DWG. S1.01) 3'-6" 15'-0" 3'-6" PROJECTION (SEE FOUNDATION PLAN DWG. S1.01) Q m m LEAVE—OUT OF SLAB LEAVE—OUT OF SLAB (3) #6 EACH WAY BOTT. 11/2" U � LL U EL. 0'-0" _ q° • ° ° ° EL. 0'-0" EL. 0'-0" _ _ „\ .� j T.O. SLAB ° : ° ° • ' ° d ° °° °d` ° • , T.O. SLAB ° d IX ° a x' y x, a ° \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ x d <'— x° `�. R, x �p ZZ • x k °° y n/� Q . ° ° . ,' ee a• °d °n V ° x °O d • . • ° \/\/\//\//\/\/\/ ° ° ° ° °° x /\\/ \\\\\\\i ' Z O Ln L /�/\/\/\/\ • • ° /\/\/\/\/\/\/\/\/\ /\/\/\/\/\/\/\/\/ •• °• ', d \/\/\/\/\/\/\/ /r TS28.24 THICKENED d • ° •< \/ , ° ° /41� /\//\//\//\//\//\\//\ SLAB EDGE ° •° I °° •" //\//\/ ° ° ° /\\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ \ /\ \ \ \ \ \ \ \ 1-011 (TE-1) 12"x12" \\ (TE-1) 12"x12" THICKENED SLAB EDGE //// // // // // // // /(TE-1) 12"x12" THICKENED // / ° // // //\// i// • • °' °• / 1/ /� /'44 THICKENED SLAB EDGE W/(2) #5 CON T. B O TT. \\/\\/\\/\\ ' r \/\\/\\/\\/�SLAB EDGE W 2 5 CON T. \/\ / —_ \ \ \ \ \ \ \ /( ) # ` \\ \ ° ��• \\ \\ 00 — —LL 4 mod, \\ \\ W/(2) #5 CONT. BOTT. \\ �• ) T.O. PIER \/ 2'—4"° °P-1 24"x24" \ \ \ \ 2'-0" \ \ ONC. PIER \ ° ° \ \ r\ 15'-0" x 55'-0" — �' i//\//\/ ° \ // — — /\// FUTURE DIP POOL \\/\\/ — ' d_. ° \/\\/\� \\/ — • a (BY OTHERS) ° . d °° \// \ \\ \\ \\ \\ \ \\ ° \\ \ \\//\\//\\/\\/\\/\\/ \.. /\\/\\/\\/\\/\\/\\/ EL. —3'-8" (P-1) 24"x24" CONC. PIER, r\ _ \ \\� V , FUTURE DIP POOL ,d g / T.O. FTG. INTO NTS28.24 CAL BARS (B S) °° m ° • ° ° • . e \//� /\/ ° • ° \\ Y OTHER • ° a° ° . ° \\j\\ 3/4" x 10" x 10" PLATE, TYP. j So ° • ° .. , d °° /\ (4) #6 x 6'-8" EL. —4'-8" \ \\/\ \ e ° • • ° LONG ® 6 0 C T.O. FOOTNG //\\//\\//\ •• ° °° d ° •°• • d°° • ° ° d• °° • d° \ Lfl \\ ° n ° ° a• d° At ° . —J--J--J--J--1--1--1--1--1--1--L— J_ SECTION �a FUTURE DIP POOL \ \ \ • (4) #6 x 36" LONGCo r\ ° • 5.0 Scale: 3/4"=1'-0" \ \ \\ ° • ° ° d \/ 6" O.C. I \ e <° \�/��/ •°d ° d w tiAS4 06 °d tl • / \j\\�/\\ -A . ° •d / EL. —6'-2" EL. —6'-2" j d • °.� °°• ° (/) `�\\/\\\ \d \ ° ° \ •\ °\• \° \ \\ T.O. FOOTING T.O. FOOTING ,\ ° \ \ \ \ \• \g F6080 FOOTI G 3" CLR (TYP) 3" CLR (TYP) F40 FOOTING F- 4'-0" Z LLI c Q7 (2) HELICAL PILES, (SEE SECTION 2/S3.01, SIMILAR) er, • PE FL 43444 � 6'-0" Allen W i e d e r, DIN:cn=Allen Wieder,PE FL 43444, x 8'-0" o=Wieder Engineering,Inc,ou, P E F L 43444 email=awieder@wiederengineerin 2 SECTION �a FUTURE DIP POOL 3 SECTION �a FUTURE DIP POOL g.com,c=us _ '1 0 5.0 Scale: 3/4"=1'-O" 5.0 Scale: 3/4"=1'-O" Date:2021.05.06 15:56:28-04'00' Lo 0 0 0 >° N N 44 w // 00 i4pu4pp ineepin Jnc. L o �� I3 STRUCTURAL ENGINEER z U) z 6 m 11718 SE FEDERAL HWY #373 Uc #28036 (772) 546-5823 m No p p N HOBE SOUND, FL 33455 FAX: (772) 545-3734 C a a @