Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY CALCS & MANUAL J - 1 DESOTO
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State,Zip: FT. PIERCE. FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Flodda Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Types(1718.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block-int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame-Wood,Adjacent R=11.0 240.00 ft 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sgft.) Insulation Area a. Under Attic(Vented) R=30.0 1306.00 ftz 6. Conditioned floor area above grade(ft2) 1306 b. z Knee Wall (Vented) R=19.0 30.00 ft Conditioned floor area below grade(ft2) 0 c. N/A R= ftz 7. Windows(128.9 sqft.) Description Area 12. Ducts, location &insulation level R ftZ a. U-Factor: Sgl, U=1.02 76.04 ftz a. a. Sup:Attic, Ret:Attic,AH:Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtulhr Efficiency c. U-Factor: Sgl, U=1.02 12.85 ftz a. Central Unit 29.0 SEERA4.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtulhr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) NIA NIA ftz SHGC(AVG): NIA 15. Hot Water Systems 9. Floor Types Insulation Area a. ElectricTankless Cap: 1 gallons a. Slab-On-Grade Edge Insulation R= 0.0 1306.00 ftz 2 EF: 0.600 b. NIA R= ft b. Conservation features c. NIA R= ftz None 16. Credits None Glass/Floor Area:0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. rq fill, �Ys`� PREPARED BY: Before construction is completed [e rlrru 'ff. this building will be inspected for CA __. . . DATE: 6'7-2021 compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed i ompliance " , with the Florida Energy Codes 0� OWNE A I . BUILDING OFFICIAL: DATE: �\ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory�sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors,tested in accordance with ANSI/RESNETIICC 380,is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 6/7/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Addresstype: Street Address BuildingType: User Bedrooms: 1 Lot#: - Owner: WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: - TotalStories: 1 PlatBook: - Builder Name: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY Rotate Angle: 180 County: St Lucie Jurisdiction: Cross Ventilation: No City,State,Zip: FT.PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New(From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE JDesign Design Temp Im Design Temp Heating Design Dailytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL,Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13UM76.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINKAREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 36612 No 2 Yes Yes Yes _6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet -1 Slab-On-Grade Edge Ins MASTER BEDROOM 31 0 234 ft 0.473 - 0.00 1.00 0.00 -2 Slab-On-Grade Edge Ins DEN 24 0 144 ft 0.473 - 0.00 1.00 0.00 _3 Slab-On-Grade Edge Ins SINK AREA 7 0 42 ft 0.473 - 0.00 1.00 0.00 _4 Slab-On-Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.0o _5 Slab-On-Grade Edge Ins GREAT ROOM 32 0 452ft OA73 - 0.00 1.00 0.00 _6 Slab-On-Grade Edge Ins MASTER BATH 5 0 50 ft 0.473 - 0.00 1.00 0.00 _7 Slab-On-Grade Edge Ins POWDER - 1 0 26ft 0.473 - 0.00 1.00 0.00 _8 Slab-On-Grade Edge Ins KITCHEN 38 0 232ft 0.473 - 0.00 1.00 0.00 _9 Slab-On-Grade Edge Ins LAUNDRY 1 0 40 ft 0.473 - 0.00 1.00 0.00 10 Slab-On-Grade Edge Ins STORAGE 21 0 24 ft 0.304 - 0.00 0.00 1.00 677/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Instil. (deg) 1 Hip Metal 1376 1 O ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio(11 in) Area RBS IRCC 1 Full attic Vented 150 1306 ft' N N CEILING (Total Exposed Area = 1336 sq.ft.) # CeilingType Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type _1 UnderAttio(Vented) MASTER BEDROOM 30.0 Blown 234.Oft' 0.053 0.10 Wood _2 UnderAttio(Vented) DEN 30.0 Blown 144.Oft2 0.053 0.10 Wood _3 UnderAttic(Vented) SINKAREA 30.0 Blown 42.Oft2 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.Oft2 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.0ft2 0.053 0.10 Wood _6 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.Oft' 0.053 0.10 Wood _7 UnderAttic(Vented) POWDER 30.0 Blown 25.Oft2 0.053 0.10 Wood _8 UnderAttic(Vented) KITCHEN 30.0 Blown 232.O112 0.053 0.10 Wood _9 UnderAttic(Vented) LAUNDRY 30.0 Blown 40.Oft2 0.053 0.10 Wood _10 UnderAttic(Vented) STORAGE 30.0 Blown 24.Oft2 0.030 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.0fI2 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note:First wall orientation below is as entered.Actual orientation is modified by the rotate angle(180 degrees)as shown in the"Project"section on page 1. / Adjacent Cavity Width Height Area U- Sheath Fnn. Solar Below �/ # Omit To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frec. Absor. Grade _1 S=>N Exterior Conc.Blk-Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Conc.Blk-Int Ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Conc.Blk-Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc.Blk-Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Conc.Bik-Int Ins SINKARF-A 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _6 N=>S Exterior Conc.Bilk-Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _7 W=>E Exterior Conc.Blk-Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% _8 S=>N Exterior Conc.Bilk-Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Cono.Bik-Int Ins KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _10 E=>W Exterior Conc.Bilk-Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% 11 S=>N Exterior Conc.Blk-Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _12 N=>S Exterior Conc.Bilk-Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _13 N=>S Exterior Conc.Bilk-Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _14 N=>S Exterior Conc.Blk-Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 N=>S Garage Frame-Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area =20 sq.ft.) / Width Height V# Omt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.Oft' 617/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) / Wall -Overhang- / # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation IntedorShade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.4fN 1.0 It 5 in 1.0 ft 5 in None None _2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft- 1.0 ft 5 in 1.0 ft 5 in None None _3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 It 5 in 1.0 It 5 in None None -4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.0tP 12.0 It 0 in 1.0 ft 5in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.9ft2 1.0 ft 5 in 1.0 ft 5in None None 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft2 1.0 ft 5 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 280 ft- 280 ft- 35 It 8 ft 11 MASS # Mass Type Area Thickness FumitureFraction Space _1 Default(81bs/sq.fL) 0 ft' 0 It 0.30 MASTER BEDROOM _2 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 DEN _3 Default(8lbs/sq.fL) 0 fF 0 It 0.30 SINK AREA _4 Default(8lbs/sq.ft.) 0 ft2 0 It 0.30 CLOSET -5 Default(81bs/sq.ft.) 0 ft2 0 It 0.30 GREAT ROOM _6 Default(81bs/sq.ft.) 0 ft2 0 It 0.30 MASTER BATH _7 Default(8lbs/sq.ft.) Oft' Oft 0.30 POWDER _8 Default(81bs/sq.fL) 0IF Oft 0.30 KITCHEN _9 Default(8lbs/sq.ft.) Oft' Oft 0.30 LAUNDRY 10 Default(8lbs/sq.ft.) 0 ft2 Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity -Geothermal HeatPump- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump Split/Single HSPF:8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfrn 1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:OOAM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length _1 Electric Tankless Garage 0.60(0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS V —Duct - Supply - — Retum------ Air CFM 25 CFM 25 HVAC# # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6.0 120 IF Attic 6.0 45 ft' Default Leakage Attic (Default)(Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans:N Cooling []Jan []Feb []Mar []Apr []May [X]Jun [X]Jul [X]Aug [X]Sep []Oct []Nov []Dec Heating [X]Jan [X]Feb [X]Mar []Apr []May []Jun []Jul []Aug [I Sep []Oct [X]Nov [X]Dec Venting []Jan []Feb [X]Mar Pq Apr [I May []Jun []Jul []Aug [I Sep [X]Oct [x]Nov []Dec VThermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 _Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 677/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number. Y Owner: WYNNE BUILDING CORP. Jurisdiction: 0 Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-penneableinsulationshall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barriershall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exteriorthermal envelope insulation forframed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,orcontinuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation,insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and cenditionedspaces. Recessed lighting Recessed lightfbdures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut really to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall onexteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barriershall be installed behind electrical or on exteriorwalls communication boxes orair-sealed boxes shall be installed. HVAC register boot HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling penetrated by the boot. Concealed When required to be sealed,concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of]CC-400. 6/7/2021 11:47:00 AM EnergyGauge®USA 7.0-FlaRes2020 FBC 7th Edition(2020)Compliant Software Pagel FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerfonnance Index,the more efficient the home. THE COTTAGE,FT. PIERCE,FL, 1. New construction or existing New(From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, ExteriorR=4.1 1478.30 ftZ b. Frame-Wood,Adjacent R=11.0 240.00 ft 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 1 d. N/A R= ftZ 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sgft.) Insulation Area a. Under Attic(Vented) R=30.0 1306.00 ft2 6. Conditioned floor area above grade(ftz) 1306 b.Knee Wall (Vented) R=19.0 30.00 ftZ Conditioned floor area below grade(ftz) 0 c. N/A R= ft2 7. Windows" Description Area 12. Ducts, location&insulation level R ftZ a. U-Factor: Sgl, U=1.02 76.04 ftz a.a.Sup:Attic, Rat:Attic,AH:Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor. Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: Sgl,U=1.02 12.85 ftz a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 It Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor(AVG) WA N/A ft2 SHGC(AVG): N/A 15. Hot Water Systems 9. Floor Types Insulation Area a. ElectricTankless Cap: 1 gallons a. Slab-On-Grade Edge Insulation R= 0.0 1306.00 ftz Z EF:0.600 c. N/A R= ftz b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise,a new EPL Display Card will be completed 1fiEBT based on installed Code compliant features. _ pi \ s o Builder Signature: �,� Date: Address of New Home: ` City/FL Zip:�S�. `Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for WE energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. 6/7/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1 Wrightsoft® Project Summary ate: Entire House By. QUICK CALCS, INC. 317ST.LUCIE LANE,FORTPIERCE,FL34946 Pivm:772-466-6799 Email:QUICKCALCS AOL.COM Probect Information For. WYNNE BUILDING CORP. THE COTTAGE,FT.PIERCE,FL Notes: Design Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Duds 4013 Btuh Duds 5251 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none ) (none Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20340 Btuh Use manufacturer's data In Rate/swingg multiplier 0.95 Infiltration Equipment sensible load 19734 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2094 Btuh Duds 1524 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cool' (none) Area(16) 1306 1306 Equipment latent load 3618 Btuh Volume(13) 10579 10579 Airchanges/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 23352 Btuh Equiv.AVF(clm) 79 41 Req.total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3000GOA0 Cond CH14NBO3000GOAD AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heating input Sensible cooling 20300 Btuh Heating output 28000 Btuh@47-F Latent000ling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Btuh Actual airflow 967 cfm Actual airflow 967 clin Airflowfactor 0.048 cfin/Btuh Airflowfador 0.047 dm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=34 OF Backup: Input=5 kW, Output=18005 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wripht5'V: ' 2021-Jan121321:40 ^�^+�-^—+ R91SULL?JUd.1WI 201919.021 RSUD8101 Pagel ...\WrighZoft NVAaWYNNEBUIDLING-THECOTTAGE.Rp Calc=NU8 Frort!Doorfa v.SW -Fr wrighllsof Job:Worksheet Data: Entire House Date: QUICK CALCS, INC. By: 317 ST.LUCIE LANE,FORTPIERCE,FL34946 PIwe:772466,6799 BMO:QUKXCALCS@AOLCOM 1 Room name Enim House MASTER BEDROOM 2 Elposedaell 145D ft 31D ft 3 Room height 8.1 it 8.1 ft heaVmol 4 Room Gmermcm 13.0 x 18D ft 5 Rcom area 13WD r 234.0 f' Ty I Cortsbucfion U-value Or HTM AreaLoad camber (BhIhAP-°F) (BWhfi9 or perimeter (f0 ( h) ors perimeter (+� (tU (en,h) Heat Cool Gross NLP/S Heat Cool Gnss NrP)S Heat Cod 6 l41 13PAos 0.143 In4A0 219 446 427 1710 934 0 0 0 0 I--G 2gkdrog,dreutr, 1.040 In 29.12 21.68 18 0 537 400) 0 0 0 0 13AA= 0.143 a 4D0 2.19 162 129 516 282 0 0 0 0 2ggla2mg.droutr, 1D40 a 29.12 39.42 13 2 368 498 0 0 0 0 11 1 to 0390 a 10.92 1034 20 20 223 211 0 0 0 0 13A4ocs 0.143 s 4D0 219 294 277 1107 605 146 146 584 319 t—G 2glaang,droutr, 1D40 s 29.12 21.68 7 7 202 150 0 0 0 0 13AA= 0.w w 4D0 2.19 284 192 767 419 105 73 291 159 1A-dom 1270 w 3556 34.77 41 41 1451 1419 0 0 0 0 lxhlom 1270 w 3556 61.76 18 3 656 1139 0 0 0 0 1A-hlom 1270 w 3556 63.40 33 5 1162 2072 33 5 1162 2072 C 16C30m1 0.032 - 0.90 128 1306 1306 1170 1672 234 234 210 300 F 22A-Vl Use - 27B9 0.00 1306 145 4015 0 234 31 858 0 6 c)AED exarsion 3591 997 Envelope lossrgain 13885 13393 3105 3847 12 a) Infiltralm 2441 W8 5n 143 b) Roomaentilabon 0 0 0 0 13 Intrimdgaim O=panls@ 230 2 460 0 0 Appliano:Jother 1000 0 Subbtal(lines6b13) 16327 155n 3627 3990 Lesexbmalload 0 0 0 0 Lestrart4er 0 0 0 0 Redistribuim 0 0 0 0 14 Subbtal 16327 15522 3627 3990 15 Dudloads 25% 34% 4013 5251 25% 34% 892 1352 Total room bad 20M 20773 1 1 4518 5342 Airmquired(dm) 967 967 215 249 Calculations approved t1vACCAto meet all requirements of Manual J 8th Ed. c -40-`^W��*'.,.,_.�._,R' 2021-Jan121321:40 RigttSdtBOUriversa1201919.021 RSL108101 w ...lWrigla oft HVAQWVNNEBUDJNG-THECOTrAGEnp CaIc=M18 FrortDoorkces:SW Page 1 wrighWoW Right-JO Worksheet Job: Entire House °atD` By. QUICK CALCS, INC. 317 ST..LUCE LANE,FORTMERCE,FL34946 PMre:77246"799 EmaiI:QUICKCALCS@AOL.COM 1 Room tame DEN SINKAREA 2 Fposadwall 24.0 ft 7.0 It 3 Room height 8.1 ft heaVmol 8.1 it heaNcool 4 Room tlimereore 12D x 12.0 it 6.0 x 7.0 it 5 Roan arm 144.0 F 42.0 iF Ty Construction U-%Wue Or HTM Area (T) Load Area (R'0 Load number (BWW,9 (BWh4P) or perimeter (t) (BWh) or perimeter M (BWh) Heat Cool G. NIPS Heat Cod Gross NIPS HIM Cool 6 V�G 13A4o s Q143 n 4.00 219 97 97 389 213 0 0 O 0 - 2glaatg,droutr, 1A40 n 29.12 21.68 0 0 0 0 0 0 0 - 0 y/ 13A4as 0.143 a 4A0 2.19 0 0 0 0 0 0 0 0 II-----DG 2glaang,draN, 1A40 a 29.12 39 0 0 0 0 0 0 0 0 11 11DO 0.3W a 10.92 10.34 0 0 0 0 0 0 0 0 W 13A4ors 0.143 s 4A0 2.19 0 0 0 0 57 57 227 124 L— G 2glaig,droutr, 1.040 s 29.12 21M 0 0 0 0 0 0 0 0 IN 13rWas 0.143 w 4A0 219 97 79 315 172 0 0 0 0 L��(C6 1Ac1om 1270 w 35M 3477 0 0 0 0 0 0 0 0 IA-htom 1270 w 35ZS 61.76 18 3 656 1139 0 0 0 0 tA411an 1270 w 35M 63,40 0 0 0 0 0 0 0 0 C- 16C301111 01W 0.90 - 128 144 144 129 184 42 42 38 -. - 54 F 22A4pl 0.989 - 27.69 O.OD 144 24 665 0 42 7 194 0 6 c)AEDex ursim 574 -3 Emelope losstgain 2154 2283 459 175 12 a) b1l4ation 404 111 118 32 b) Roomsentilaoon 0 0 0 0 13 hlsral gains Occuparra@ 230 0 0 0 0 Appliancesblher 0 0 Subtotal(titas6m 13) 2558 2394 576 207 Lessexemalload 0 0 0 0 Lesstransrer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2558 2394 576 207 15 Dud loads 25% 34-A 629 811 25% 34% 142 70 Total mom load 3187 IT45 718 278 Air required(orm) 152 149 34 13 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Rgk a 9.021 RS I08101 2021-Jrv121321:40 AG \WdgtiofthNAgWVNNEBUIDLING-THECO7rAGEnp Cab=96 FrortDoorfaoes:SW Page 2 wrightsoft Right-J®Worksheet Joa Entire House per: QUICK CALCS, INC. By. 317 ST.LUCIE LANE.FORTMERCE,FL34946 Fiore:772-4666799 Em i:QUICKCALCS@AOL.COM 1 Roomr CLOSET GREAT ROOM 2 Epo:edvall 0 it 32D it 3 Roan height 8.1 ft heat/boo[ 8.1 ft heaVbod 4 Room dimensions 9A x 7.0 It to x 452A it 5 Room area 63.0 W 452A tF Ty Construction U-%due Or HTM Area (fe) Load Area (M Load number (BWhVL*g (BWh4l'0 or perimeter (1t) MWh) or perimeter M (BWh) Heat Cool Gros NIPS Heat Cad Gross NIPS Heat Cool 6 W - 13A-0as 0.143 n 4A0 219 0 0 0 0 178 160 640 350 L—C 2glaang,droW, 1.040 n 29.12 21.68 0 0 0 0 18 0 537 400 Vfl 13AAM 0.143 a 4A0 2.19 0 0 0 0 0 0 0 0 IL--DG 2glaarg,droutr, 1A40 a 29.12 39A2 0 0 0 0 0 0 0 0 it 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 t13AA= 0.143 s 4A0 2.19 0 0 0 - 0 0 0 0 0 —G 2glaarg,droutr, 1A40 s 29.12 21.68 0 0 0 0 0 0 - 0 0 Ti13A-0as 0.143 w 4A0 2.19 0 0 0 0 81 40 161 88 11A Ion 1270 w 3556 34.77 0 0 0 0 41 41 1451 1419 IA411om 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-h1w 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C-30mi ODN - 0.90 128 63 63 56 81 462 462 405 579 F 22A-10 0.989 - 27.69 0.00 63 0 0 0 452 32 B86 0 6 C)AEDe>mmn -1 2D69 Envelope loms;ain 56 80 1 4080 4903 12 a) Nitration 0 0 539 148 b) Roomvedlatian 0 0 0 0 13 li gaim O=pants@ 230 0 0 2 460 Applianceslolher 0 0 Subtotal(liires6to 13) 56 80 4619 5511 Lese+temalload 0 0 0 0 LestrarMer 0 0 0 0 Redistribulion 0 0 0 0 14 Subtotal 56 80 4619 5511 15 Durtloads 25% 34% 14 27 25% 34 1135 1868 Total room load 70 107 6754 7379 Airrequired(dm) 3 5 1 274 343 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. c 2021JarF121321:40 Icp Rgt-THE COTrA reaAV Ca9.021 RSU08101 Page 3 _..\WrigtLsoRHVAC\WYNNE BUIDLING-hIE COTTAGEnp CaIc=MI6 Front Ooorfaces:SW 9 wrightsoft° Right-M)Worksheet QC&. Entire House °abe: QUICK CALCS, INC. BY 3179T.LUCIE LANE,FORTPIERCE,FL34946 Phw :T2-4666799 EmaiI:QUICKCALCSQAOL.00M 1 Room name MASTER BATH POWDER 2 Exposed wall 5D it 0 it 3 Room height 8.1 it heabbDd 8.1 It heaNmol 4 Room dimensbns 10.0 x 5D it5D x 5D ft 5 Room area 50.0 ff 25.0 IF Ty Corsrucion U-kelue or HTM Area Load Area number (BWhM'-°F) (BWhfi� or p�im� (t) (fiWh) or perimeter (11) (Bluh) Heat Cool Gros NIP1S Heat Cool Gms NP/S Heat Cool 6 1M 13A-4ors 0.143 n 4D0 219 0 0 0 0 0 0 0 0 �G 2glaarg,crou1r, 1.O4O n 29.12 21.68 0 0 0 0 0 0 0 0 13A4o s 0.143 a 4D0 219 0 0 0 0 0 0 0 - 0 2giaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0390 a 10.92 10.34 0 0 0 0 0 0 0 0 1p/ IVA= O7 s 4.00 Z19 41 34 134 73 0 0 0 _ _ 0 �C 2glaarg.droutr, 1D40 s 29.12 21.68 7 7 202 150 0 0 0 0 13A4o6 0-143 w 4.00 2.19 0 0 0 0 0 0 0 0 IA-dom 1270 w 3556 34.77 0 0 0 0 0 0 0 0 1A-h1om 1270 w 3556 61.76 0 0 0 0 0 0 0 0 lhhlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 c 16C-30ml 0.032 - 0.91) 128 50 50 45 64 25 25 22 32. F 22AApl 0.I9 - 2729 OAO 50 5 138 0 25 0 0 0 6 c)AEDe=rsion -4 0 Syvelope bss�pn 520 284 22 32 12 a) Infiltration 84 23 0 0 b) Roomventlation 0 0 0 0 13 hlemal gains: O=pants oQ 230 0 0 0 0 Applianosbther 0 0 Subbbl(Iines 6 b 13) 604 307 221 32 Lese)demalload V 0 0 0 0 L. transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 604 307 22 32 15 Ductloads 25% 349j 148 104 25'/e 34% 6 11 Total room load 752 411 28 42 Air required(Qm) 36 19 1 2 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed " wri9Miso1'!� .MCA RgkSute®lhivers1207979.027 RSW8707 20214arM27327:40 ...\Wri tZoftWAgWYNNESUDLING-THECOT7AGE Page 9 np Calc=M76 Fmrt Doorfaos:SW wrightsoft' Right-M)Worksheet JOd' Entire House Dfit By. QUICK CALCS, INC. 317 ST..LUCIE LANE,FORTMERCE,FL34946 Phone:772.466.6799 Email:OUICKC4LCS@AOL.00M 1 Room name WCHFN LAUNDRY 2 Blposdmll 38A ft 0 ft 3 Room height 8.1 It hedbDOl 8.1 It heaVmol 4 Room dimensions I x 232D ft 4.0 x 10.0 ft 5 Room area 232.0 1F 40D iF Ty Construction U-value Or HTM Area (IF) Load Area Load number (BWhgF-*n (BWhAM or perimeter (ft) (BWh) ar perimeter (it) (BWh) Heat Cool Gros NIPS Heat Cool Gross NIPS Heat Cool 6 vrl 13AAM 0.143 n 4.00 Z19 138 138 551 301 0 0 0 0 L—C 2glaarg,droutr, 1.040 n 29.12 21M 0 0 0 0 0 0 0 0 1344ors 0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 2 glazing,droutr, tA40 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11D0 0390 a 10.92 10 20 20 223 211 0 0 0 0 Vy 13A-4= 0.143 s 4.OD 2.19 41 41 162 89 0 0 0 0 L—G 2glaarg,droutr, ID40 s 29.12 21.68 0 0 0 0 0 0 0 0 13A l= 0.143 w 4A0 Z19 0 0 O 0 0 0 0 0 1Ac1om 1270 w 3556 34.77 0 0 0 0 0 0 0 0 1A-hi m 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1Ah1om 12M w 3556 63.40 0 0 0 0 0 0 0 0 C 16C-30nl 0.032 - 0.90 128 232 232 208 297 40 40 36 61 F 22A-Qtl 0.909 - 27.69 Om 232 38 1052 0 40 0 0 0 6 c)AED excursion 37 4 Envelope losslgain 2951 1570 36 51 12 a) IMIGation 640 175 0 0 b) Rown%entilafion 0 0 0 0 13 Intemalgaim Omtpants@ 230 0 0 0 0 Appliances'olher 1000 0 Subbtal(lines6toi3) 3591 2745 36 51 Lesedamalload 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subbhl 3591 2745 36 51 15 Dudloads 25% 34% 883 931 25% 34% 9 17 Total room bad 4474 3676 45 68 Air required(dm) 213 171 2 3 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. +I-- 2021-Jan-121321:40 lak %ttSUteOLhiwml201919.021 RSL108101 Page 5 ...\Wdgl6oft HVAaW NEBUIOLWG-THECOTMGE.np Calc=M18 FmODoorla SW t wrightsoft Right-J®Worksheet Joe: Entire House Date: QUICK CALCS, INC. I6y. 3175T.LUCIE LANE.FORT PIERCE.FL34946 Phone 772466-6799 Email:OUICKCALCS@�1 OL.COM 1 Room name STORAGE 2 Exposdvrall 8.0It 3 Room height 8.1 It heaV000l 4 Room dimeasoas 4.0 x 6A It 5 Room area 24.0 IF Ty Construction U-value Or HTM Area (ft') Load Area Load number (BWh/V° F) (BUhXP'`) or perimeter (R) (BNh) or perimeter Heat Cool Gros NiP/S Heat Cool Gras N/P/S Heat Cool 6 l{J 13A-4= 0.143 n 4.00 2.19 32 32 130 71 �G 2giaang,droutr, 1.040 n 29.12 21.68 0 0 0 0 13A4ocs 0.143 a 4.00 2.19 32 32 130 71 2glaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 vrl 13A4= 0.143 s 4.00 2.19 0 0 0 0 L—a 2glaang,droutr, 1.040 s 29.12 21.68 0 0 0 0 13AA= 0.143 w 4.00 2.19 0 0 0 0 1Aclom 1270 w 35.56 34.77 0 0 0 0 1A-hlom 1270 w 35.56 61.76 0 0 0 0 1A-hlam 1270 w 3556 63.40 0 0 0 0 C 16C-30ml 0.032 - 0.90 128 24 24 22 31 F 22A-tpi 0.989 27.69 0.00 24 8 9" 0 I 6 c)AEDe rson -3 Envelope loss/gain 502 170 12 a) InfiltAon 135 37 b) Room ventilation 0 0 13 Intemalgains O—Pan%@ 230 0 0 Appltanoedother 0 SubtNal(lines6013) 637 207 Lese>demal load 0 0 Lestrartder 0 0 Redistributon 0 0 141 Subtotal 637 207 15' Duct loads 25% 29% 157 60 AirTotal room load 7gq 266 required,c 38 12 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed - wrlgFrrL�'oTC� 2021-JaM21321:40 .9C�A Rigk-SJte®UrrAGE.1201919.021 RS rod 0G Page6 ...\WdgtEai[HUACIWYNNE BUIDLING-THE COTiAGE.nP CaIc=MJB Frort Ooortaoas SW wrightsoft` Duct System Summa Jam: y ry Date: Entire House By. QUICK CALCS. INC. 317 ST.LUCIE LANE,FORTPIERCE,FL34946 Ptnre:772/56-6799 Email:QUICKCALCS@AOLCOM Project • For. WYNNE BUILDING CORP. THE COTTAGE,FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.28 in H2O 028 in H2O Available static pressure 022 in H2O 022 in H2O Supply/return available pressure 0.110/0.110 in H2O 0.110/0.110 in H2O Lowesttdcbon rate 0.080 in/10011 0.080 in/100ft Actual airflow 967 dim 967 ch Total eftective length(TEL) 126 ft SupplyDetail Table Design Htg Clg Design Diam H x W Dud Actual Ftg.Egv Name (Btuh) (dm) (dm) FIR (in) (in) Mat Ln(ft) Ln(ft) Trunk CLOSET c 107 3 5 0.080 4.0 OxO VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO VIFx 33.5 90.0 st1 GREAT ROOM c 3689 137 172 0.080 8.0 Ox0 VIFx 14.6 70.0 GREAT ROOM-A C 3689 137 172 0.080 8.0 Ox0 VIFx 16.1 70.0 Knrl-EN h 4474 213 171 0.080 7.0 OxO VIFx 4.5 70.0 LAUNDRY c 68 2 3 0.080 4.0 OxO VIFx 5A 70.0 MASTERBATH h 752 36 19 0.080 4.0 0x0 VIFx 32.9 90.0 SH MASTERBEDROOM c 2671 107 124 0.080 7.0 0x0 VIFx 27.9 90.0 st1 MASTERBEDROOM-A c 2671 107 124 0.080 7.0 OxO VIFx 35.9 90.0 st1 POWDER c 42 1 2 0.080 4.0 0x0 VIFx 292 90.0 SH SINKAREA h 718 34 13 0.080 4.0 0x0 VIFx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 Ox0 VIFx 112 70.0 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam HxW Dud Name Type (cfm) (cim) FR Rpm) (in) (in) Material Trunk st1 PeakAVF 441 437 1 0.080 561 12.0 0 x 0 VinIFIX wrightSoft® 2021-,1 rv121321:41 I-:_, •...�.� �w.+s.,um.e, MgftSUte®UriversaI201919.021 RSU08101 Page 1 -'M ...�wngt RWAOWY NEBUIDLING-T ECOTTAGEn Qalc=lvU8 Frort Doorfa SW Return Branch Detail Table Grille Htg CIg TEL Design Meloc I Diam HxW Stud/Joist Du Name Size(in) (Cfm) (CfM) 00 FR (fpm) (in) Qn) Opening(in) �MajtTrunk rbl Ox0 967 967 0 1 0 0 0 Ox 0 1 MR -Fp- Wrlghtsoft- 2021Jah121321A1 A •..+� w=—..o-...� PogkSdt @LkiWM1201919.021 RSU08101 PaW2 ...\Wngfloft HVAC\WVNNESUIDLINGTHECOTfAGE.r CWc=MB Fo Dowb.SW