VARIABLE SPEED FAN COILS
ALL MODELS
·2, 3, 4, and 5 Tons
·Supports two−stage outdoor units
·Available for environmentally balanced R−410A systems
·Bolt−on, hard shut−off TXV metering device factory installed
on all models
·Sweat connections
·Primary and secondary drain fittings with brass inserts
·Time delay relay (TDR)
·Field installed heater packages from 5 kW − 30 kW available
separately
·HUD approved for manufactured housing
·208/230−1−60 supply voltage
·Multiposition installation − upflow or horizontal left standard,
horizontal right with minor modification (field convertible to
downflow with accessory kits)
·Filter (washable) factory supplied
·Heat staging option
·Dehumidification function with standardized logic (same as
furnaces and SPP).
·1 inch (25mm) thick insulation with R value of 4.2
PERFORMANCE
·Variable speed ECM motor on all models
·Adjustable cooling and heating ON/OFF delay
·Heat Pump Comfort option to provide higher than normal
heating air delivery temperature
·Assembled at the factory compliant with low leak
requirements of less than 2% cabinet leakage rate at 0.5
inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C.
when tested in accordance with ASHRAE 193 standard.
EASY TO INSTALL AND SERVICE
·Multiple electrical entry locations
·TXV and manifold positioned to the side for easier cleaning
·Zero clearance without heaters
WARRANTY*
·10 year No Hassle replacement limited warranty
·5 year parts limited warranty
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org .
− With timely registration, an additional 5 year parts limited warranty
*For owner occupied, residential applications only. See warranty certificate for complete
details and restrictions, including warranty coverage for other applications.
Model
Number Tons
Nominal
BTU
CFM (L/s) Range Dimensions
H x W x D in. (mm)Filter Size in. (mm)
Ship Wt.
lbs. (kg)Low High
FVM4X2400B**2 24,000 350 (165)1200
(566)
42−11/16 x 17−5/8 x 22−1/16
(1084 x 448 x 560)
16−3/8 x 21−1/2
(416 x 546)135 (61)
FVM4X3600B**3 36,000 415 (196)1400
(661)
53−7/16 x 21−1/8 x 22−1/16
(1357 x 537 x 560)
19−7/8 x 21−1/2
(505 x 546)150 (68)
FVM4X4800B**4 48,000 425 (201)1600
(755)
53−7/16 x 21−1/8 x 22−1/16
(1357 x 537 x 560)
19−7/8 x 21−1/2
(505 x 546)172 (78)
FVM4X6000B**5 60,000 540 (255)2000
(944)
59−3/16 x 24−11/16 x 22−1/16
(1503 x 627 x 560)
23−5/16 x 21−1/2
(592 x 546)207 (94)
** B = Copper Tube, Aluminum Fin Evaporator
BL = Aluminum Tube, Aluminum Fin Evaporator
BT = Tin Coated Copper Tube, Aluminum Fin Evaporator
FVM4X−B
Product Specifications
PRODUCT SPECIFICATIONS Fan Coils: FVM4X
2 496 21 5104 03Specifications are subject to change without notice.
FAN COIL MODEL NUMBER IDENTIFICATION GUIDE
F V M 4 X 2400 B L
F = Fan Coil
V = Variable speed ECM motor MOTOR TYPE
M = Multiposition INSTALLATION TYPE
4 = Environmentally Sound R−410A REFRIGERANT
X = TXV METERING DEVICE
2400 = 24,000 BTUH = 2 tons
3600 = 36,000 BTUH = 3 tons
4800 = 48,000 BTUH = 4 tons
6000 = 60,000 BTUH = 5 tons NOMINAL CAPACITY
B = Copper Tube, Aluminum Fin Evaporator
BL = Aluminum Tube, Aluminum Fin Evaporator
BT = Tin Coated Copper Tube, Aluminum Fin Evaporator SALES CODE / FEATURES
ACCESSORIES PART NUMBER IDENTIFICATION GUIDE
EB AC 01 NCB A
EB = Evaporator Blower
AC = Accessory
01 = Product Identifier Number
NCB = Non−Combustible Base Kit
DFK = Down Flow Kit
PLG = Power Plug (no heat kit)
SPK = Single Point Wiring Kit
FKS = Filter Kit Small
FKM = Filter Kit Medium
FKL = Filter Kit Large
FKX = Filter Kit Extra Large
CTK = Condensate Trap Kit (PVC pipe)
Sales Code
ELECTRIC HEATER MODEL NUMBER IDENTIFICATION GUIDE
EHK 05 A K N 1
EHK = Electric Heater Kit
05 = 5 kW
07 = 7 kW
09 = 9 kW
10 = 10 kW
15 = 15 kW
18 = 18 kW
20 = 20 kW
25 = 25 kW
30 = 30 kW NOMINAL HEAT VALUE
Sales Code
K = 208 / 230 single−phase
H = 208 / 230, 3−phase
KC = 208 / 230, supplied as single phase, field convertible to 3−phase
HC = 208 / 230 supplied as 3−phase, field convertible to single phase VOLTAGE (60 Hz)
Product Identifier
Engineering Code
Dimensions Inches (English)PRODUCT SPECIFICATIONS Fan Coils: FVM4X496 21 5104 033Specifications are subject to change without notice.
Upflow
(as shipped)
Upflow
(as shipped)
Downflow
(field converted with accessory kits)
Downflow
(field converted with accessory kits)
Horizontal Right
(field converted with accessory kits)
Horizontal Right
(field converted with accessory kits)
Dimensions Inches (English)PRODUCT SPECIFICATIONS Fan Coils: FVM4X4496 21 5104 03Specifications are subject to change without notice.
Dimensions MM (SI Metric)
273.0
157.2
66.7
265.1
38.1
47.6
77.8
119.1
25.4
258.8
560.4
34.9
49.2
OPENING
503.2
54.0
25.4
31.8
A
23.8
30.2
E
25.4
127.0
D
241.3
MAX
22.2279.4
44.4
482.6
UNIT CONNECTION SIZES
SUCTION: 002 & 003 − 19.05 I. D. SWEAT
005 & 006 − 22.23 I. D. SWEAT
LIQUID: 9.53 I.D. SWEAT
CONDENSATE: 19.0 FPT
1. SERIES DESIGNATION IS THE 14TH POSITION
OF UNIT PRODUCT NUMBER.
2. ALL DIMENSIONS ARE IN MM UNLESS NOTED.
NOTE: ALLOW 533.4 FROM FRONT
FOR SERVICE
BLOWER, CONTROL,
& ELECTRIC HEATER
ACCESS PANEL
COIL ACCESS
PANEL
DISCONNECT OR
CIRCUIT BREAKER
LOCATION
LIQUID LINE CONNECTION
SUCTION LINE CONNECTION
FILTER ACCESS
PANEL
FITTING
PANEL
ACCESS PANEL CONFIG. FOR
SLOPE COILS
DOWNFLOW OR HORIZ.
RIGHT APPLICATIONS
AND
A COILS
DOWNFLOW APPLICATIONS
RIGHT SIDE VIEW
TOP VIEW
LIQUID LINE
CONNECTION
LIQUID LINE
CONNECTION
SUCTION LINE
CONNECTION
FRONT VIEW
SLOPE COIL DETAILS
CONNECTION LOCATIONS SHOWN
FOR UPFLOW OR HORIZ.
LEFT APPLICATIONS
OPTIONAL FIELD CONVERTED
RIGHT SIDE RETURN OPENING
(SLOPE COIL UNITS ONLY)
FOR LOW VOLTAGE
CONTROL WIRING
ALTERNATE
22.23,27.78,54.80 DIA. K.O.’S
FOR HIGH VOLTAGE
POWER WIRING
OPPOSITE SIDE
INLET AIR
INLET AIR
INLET AIR
OUTLET AIR
22.23 DIA. K.O.
FOR LOW VOLTAGE
CONTROL WIRING
22.23, 27.78
54.80 DIA. K.O.’S
FOR HIGH VOLTAGE
POWER WIRING
OPENING
J PRODUCT SPECIFICATIONS Fan Coils: FVM4X496 21 5104 035Specifications are subject to change without notice.
Upflow
(as shipped)
Upflow
(as shipped)
Downflow
(field converted with accessory kits)
Downflow
(field converted with accessory kits)
Horizontal Right
(field converted with accessory kits)
Horizontal Right
(field converted with accessory kits)
Dimensions MM (SI Metric)
200.0 30.2
38.1
200.0
30.2
38.1
31.8
82.6
41.3
82.6
65.1
73.0
25.4 TYP.
(2 PLACES)
11.1 TYP.
(2 PLACES)*
25.4 TYP.
(2 PLACES)*
11.1 TYP.
(4 PLACES)
22.2
TYP.*
54.0
41.3
46.0
TYP*
46.0
TYP.
46.0
TYP.*
8.0
TYP*
8.0
TYP.*
8.0
TYP.*
22.2
TYP.*
22.2
TYP*
12.7
TYP*68.3
79.4
73.0
127.0
31.8
149.2 77.8
120.6
149.2
8.0
TYP.*
12.7
TYP.*31.8
55.6 TYP.
(2 PLACES)*
GF
F
31.8
25.4 TYP.
(2 PLACES)*
120.6
77.8
F
55.6 TYP.
(2 PLACES)*
G
AIRFLOW
AIRFLOW AIRFLOW
* HORIZONTAL MOUNT LOCATIONS − DIMPLES PROVIDED IN TOP PANEL,
AND BACK OF CABINET. IN CABINET BOTTOM. HOLES PROVIDED
3.45 DIA. HORIZONTAL HANGING HARDWARE TO BE FIELD SUPPLIED.
PRIMARY DRAIN
SECONDARY DRAIN
SECONDARY DRAIN
SLOPE COIL
A−COIL
PRIMARY DRAIN
SECONDARY DRAIN
SECONDARY DRAIN
PRIMARY DRAIN
PRIMARY DRAIN
PRIMARY DRAIN
SECONDARY DRAIN
PRIMARY DRAIN
SECONDARY DRAIN
AIRFLOW
SECONDARY DRAIN
PRIMARY DRAIN PRODUCT SPECIFICATIONS Fan Coils: FVM4X6496 21 5104 03Specifications are subject to change without notice.
PRODUCT SPECIFICATIONS Fan Coils: FVM4X
496 21 5104 03 7Specifications are subject to change without notice.
DIMENSIONAL DATA (refer to drawings on previous pages)
FVM4X
Model
Size
(tons)
Dimensions Inches (English)Coil
TypeABCDEFGHJ
2400 2 42−11/16 17−5/8 15−3/4 15−3/8 10−3/4 18−9/16 18−1/4 N/A N/A “A”
3600 3 53−7/16 21−1/8 19−1/4 19−1/8 19−3/16 26−15/16 27−1/2 N/A 19 Slope
4800 4 53−7/16 21−1/8 19−1/4 19−1/8 19−1/2 27−1/4 26−15/16 N/A N/A “A”
6000 5 59−3/16 24−11/16 22−3/4 22−11/16 25−1/4 32−15/16 32−5/8 34−1/16 N/A “A”
FVM4X
Model
Size
(tons)
Dimensions mm (SI Metric)Coil
TypeABCDEFGHJ
2400 2 1084 448 400 397 273 472 464 N/A N/A “A”
3600 3 1357 537 489 486 487 684 699 N/A 483 Slope
4800 4 1357 537 489 486 495 692 684 N/A N/A “A”
6000 5 1503 627 578 576 641 837 829 865 N/A “A”
PHYSICAL DATA
FVM4X
Model Size
2400 3600 4800 6000
Blower Data
Motor type Variable Speed ECM motor
HP 1/2 1/2 1/2 3/4
Filter Data (factory supplied, washable)
Filter Size in. (mm)16−3/8 x 21−1/2 (416 x 546)19−7/8 x 21−1/2 (505 x 546)23−5/16 x 21−1/2 (592 x 546)
Coil Data (all coils are 3 row, 14−1/2 fins per inch, wavy lanced bare aluminum fin)
Face Area ft2 (m2)3.46 (0.32)3.46 (0.32)5.93 (0.55)7.42 (0.69)
Refrigerant Line Connections (sweat)
Liquid in. (mm)3/8 (10)3/8 (10)3/8 (10)3/8 (10)
Suction in. (mm)3/4 (19)7/8 (22)7/8 (22)7/8 (22)
ELECTRICAL DATA, FAN COIL ONLY WITHOUT ELECTRIC HEAT
FVM4X Model
208/230V, single phase, 60 Hz
Motor Full Load
Amps (FLA)
Minimum Circuit
Ampacity (MCA)
Maximum Fuse/Ckt Bkr Amps
(Max OverCurrent Protection − MOCP)
2400 4.3 5.4 15
3600 4.3 5.4 15
4800 4.3 5.4 15
6000 6.8 8.5 15
AIRFLOW PERFORMANCE − CFM RANGE
FVM4X Model Use with Outdoor Unit Size CFM (L/s) Range
2400 18, 24, 30, 36 350−1200 (165 − 566)
3600 24, 30, 36, 42 415−1400 (196 − 661)
4800 30, 36, 42, 48 425−1600 (201 − 755)
6000 36, 42, 48, 60 540−2000 (255 − 944)
PRODUCT SPECIFICATIONS Fan Coils: FVM4X
8 496 21 5104 03Specifications are subject to change without notice.
AIRFLOW PERFORMANCE − CFM IN COOLING MODE (A/C or Heat Pump)
FVM4X
Model
Outdoor
Unit
Size
Single Stage
Cooling
Two −Stage Cooling
Fan OnlyHighLow
Nominal Dehum Nominal Dehum Nominal Dehum Low Med Hi
2400
18 525 420 Two−Stage outdoor unit not offered 350 420 525
24 700 560 700 560 560 450 350 560 700
30 875 700 Two −Stage outdoor unit not offered 440 700 875
36 1050 840 1050 840 840 670 525 840 1050
3600
24 700 560 700 560 560 450 415 560 700
30 875 700 Two −Stage outdoor unit not offered 440 700 875
36 1050 840 1050 840 840 670 525 840 1050
42 1225 980 Two −Stage outdoor unit not offered 615 980 1225
4800
30 875 700 Two −Stage outdoor unit not offered 440 700 875
36 1050 840 1050 840 840 670 525 840 1050
42 1225 980 Two −Stage outdoor unit not offered 615 980 1225
48 1400 1120 1400 1120 1120 900 700 1120 1400
6000
36 1050 840 1050 840 840 670 540 840 1050
42 1225 980 Two −Stage outdoor unit not offered 615 980 1225
48 1400 1120 1400 1120 1120 900 700 1120 1400
60 1750 1400 1750 1400 1400 1120 875 1400 1750
NOTES:
1. The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM.
2. Airflow can be adjusted +15% or −10% by selecting Hi or Lo respectively for all modes except fan only.
3. Dry coil at 230 volts and with 10kW heater and filter installed.
4. Airflows shown are valid for systems with total external static pressure between 0.1 and 0.7 inches water column.
AIRFLOW PERFORMANCE − CFM IN HEAT PUMP HEATING MODE ONLY
FVM4X
Model
Outdoor
Unit
Size
Single Stage HP
Heating
Two −Stage HP Heating
Fan OnlyHighLow
Comfort Eff Comfort Eff Comfort Eff Low Med Hi
2400
18 475 525 Two−Stage outdoor unit not offered 350 380 475
24 630 700 630 700 505 560 350 505 630
30 785 875 Two −Stage outdoor unit not offered 440 630 785
36 945 1050 945 1050 755 840 525 755 945
3600
24 630 700 630 700 505 560 415 505 630
30 785 875 Two −Stage outdoor unit not offered 440 630 785
36 945 1050 945 1050 755 840 525 755 945
42 1100 1225 Two −Stage outdoor unit not offered 615 880 1100
4800
30 785 875 Two −Stage outdoor unit not offered 440 630 785
36 945 1050 945 1050 755 840 525 755 945
42 1100 1225 Two −Stage outdoor unit not offered 615 880 1100
48 1260 1400 1260 1400 1010 1120 700 1010 1260
6000
36 945 1050 945 1050 755 840 540 755 945
42 1100 1225 Two −Stage outdoor unit not offered 615 880 1100
48 1260 1400 1260 1400 1010 1120 700 1010 1260
60 1575 1750 1575 1750 1260 1400 875 1260 1575
NOTES:
1. The above airflows result with the AC/HP CFM ADJUST select jumper set on NOM.
2. Airflow can be adjusted +15% or −10% by selecting Hi or Lo respectively for all modes except fan only.
3. Dry coil at 230 volts and with 10kW heater and filter installed.
4. Airflows shown are valid for systems with total external static pressure between 0.1 and 0.7 inches water column.
PRODUCT SPECIFICATIONS Fan Coils: FVM4X
496 21 5104 03 9Specifications are subject to change without notice.
AIRFLOW DELIVERY (CFM)
FVM4X
Model
Outdoor
Unit
Capacity
(BTUH)
Electric Heater kW Range
0 − 5 0 − 10 0 − 15 0 − 20
LO NOM HI LO NOM HI LO NOM HI LO NOM HI
2400
18 625 625 625 675 675 675 ******
24 650 725 835 *725 835 875 875 875 ***
30 815 905 1040 *905 1040 900 900 1040 1100 1100 1100
36 980 1085 1250 980 1085 1250 980 1085 1250 1100 1100 1250
3600
24 675 725 835 875 875 *******
30 815 905 1040 875 905 1040 1100 1100 1100 ***
36 980 1085 1250 980 1085 1250 1100 1100 1250 1225 1225 1250
42 1140 1270 1460 1140 1270 1460 1140 1270 1460 1225 1270 1460
0 − 10 0 − 15 0 − 20 0 − 30
4800
30 975 975 1040 1100 1100 1100 ******
36 980 1085 1250 1100 1100 1250 1250 1250 1250 ***
42 1140 1270 1460 1140 1270 1460 1250 1270 1460 ***
48 1305 1450 1665 1305 1450 1665 1305 1450 1665 1500 1500 1665
6000
36 1100 1100 1250 1350 1350 1350 ******
42 1140 1270 1460 1350 1350 1460 1525 1525 1525 ***
48 1305 1450 1665 1350 1450 1665 1525 1525 1665 1750 1750 1750
60 1630 1810 2085 1630 1810 2085 1630 1810 2085 1750 1810 2085
* Airflow not recommended for heater/system size
NOTE: LO, NOM, and HI refer to AC/HP CFM ADJUST selection on the control board.
HEAT PUMP MINIMUM CFM WHEN USING ELECTRIC HEAT (CFM)
FVM4X
Model
Outdoor
Unit Size
Heater Size kW
5 8, 9, 10 15 18, 20 24, 30
2400
18 625 625 −−−−−−
24 650 725 875 −−−−
30 800 875 875 1040 −−
36 970 970 970 1040 −−
3600
24 675 875 −−−−−−
30 800 875 1100 1150 −−
36 975 975 1100 1225 −−
42 1125 1125 1125 1225 −−
4800
30 800 875 875 1150 −−
36 975 975 1100 1225 −−
42 1125 1125 1125 1225 −−
48 1305 1305 1305 1305 1400
6000
36 1100 1100 1350 1350 −−
42 1125 1125 1350 1350 −−
48 1300 1300 1350 1465 1750
60 1625 1625 1625 1750 1750
A/C MINIMUM CFM WHEN USING ELECTRIC HEAT (CFM)
FVM4X Model
Heater Size kW
5 8, 9, 10 15 18, 20 24, 30
2400
Heater Only
625 625 725 875 −−
3600 675 700 850 1050 −−
4800 675 700 850 1050 1400
6000 1050 1050 1050 1050 1750
NOTES:
1. Heater Only−Air conditioner with electric heater application.
2. These airflows are minimum acceptable airflows as UL listed. Actual airflow delivered will be per airflow delivery chart forElectric Heating Modes.
PRODUCT SPECIFICATIONS Fan Coils: FVM4X10496 21 5104 03Specifications are subject to change without notice.ELECTRIC HEATER ELECTRICAL DATA
Heater Model
Heater kW
PHASE
INTERNAL
CIRCUIT
PROTECTION
HEATER AMPS
208/230V
BRANCH CIRCUIT
Min Ampacity
208/230V
Min Wire Size (AWG)
208/230V 1
Min Gnd Wire Size
208/230V
Max Fuse/Ckt Bkr Amps
208/230V
Max Wire Length
208/230V (Ft)‡‡
Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit Single
Circuit
Dual Circuit
230v 208v L1,l2 L3,L4 L1,L2 L3,L4 L1, L2 L3, L4 L1, L2 L3,L4 L1,L2 L3,L4 L1,L2 L3,L4
EHK05AKN*5 3.8 1 None 18.1/20.0 ——26.0/28.4 ——10/10 ——10/10 ——30/30 ——66/66 ——
EHK05AKN**5 3.8 1 None 18.1/20.0 ——31.2/33.5 ——8/8 ——10/10 ——35/35 ——85/88 ——
EHK05AKB*5 3.8 1 Ckt Bkr 18.1/20.0 ——26.0/28.4 ——10/10 ——10/10 ——30/30 ——66/66 ——
EHK05AKB**5 3.8 1 Ckt Bkr 18.1/20.0 ——31.2/33.5 ——8/8 ——10/10 ——35/35 ——85/88 ——
EHK07AKN 8 6.0 1 None 28.9/32.0 ——44.7/48.5 ——8/8 ——10/10 ——45/50 ——59/60 ——
EHK07AKB 8 6.0 1 Ckt Bkr 28.9/32.0 ——44.7/48.5 ——8/8 ——10/10 ——45/50 ——59/60 ——
EHK09AKCN
9 6.8 1 None 32.8/36.0 ——49.5/53.5 ——8/6 ——10/10 ——50/60 ——54/87 ——
9 6.8 3 None 18.8/20.8 ——32.0/34.5 ——8/8 ——10/10 ——35/35 ——83/85 ——
EHK10AKN 10 7.5 1 None 36.2/40.0 ——53.8/58.5 ——6/6 ——10/10 ——60/60 ——78/80 ——
EHK10AKB 10 7.5 1 Ckt Bkr 36.2/40.0 ——53.8/58.5 ——6/6 ——10/10 ——60/60 ——78/80 ——
EHK15AKF 15 11.3 1 Fuse 54.2/59.9 36.2/40.0 18.1/20.0 76.3/83.4 53.8/58.5 22.7/25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 60/60 25/25 88/89 78/80 75/76
EHK15AKB 15 11.3 1 Ckt Bkr —36.2/40.0 18.1/20.0 —53.8/58.5 22.7/25.0 —6/6 10/10 —10/10 10/10 —60/60 25/25 —78/80 75/76
EHK15AHN 15 11.3 3 None 31.3/34.6 ——47.7/51.8 ——8/6 ——10/10 ——50/60 ——56/90 ——
EHK18AHN 18 13.5 3 None 37.6/41.5 ——55.5/60.4 ——6/6 ——10/8 ——60/70 ——76/77 ——
EHK20AKF 20 15.0 1 Fuse 72.3/79.9 36.2/40.0 36.2/40.0 98.9/108.4 53.8/58.5 45.3/50.0 3/2 6/6 8/8 8/6 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59
EHK20AKB 20 15.0 1 Ckt Bkr —36.2/40.0 36.2/40.0 —53.8/58.5 45.3/50.0 —6/6 8/8 —10/10 10/10 —60/60 50/50 —78/80 59/59
EHK25AHCF
24 18.0 3 Fuse 50.1/55.4 ——71.2/77.8 ——4/4 ——8/8 ——80/80 ——94/95 ——
24 18.0 1 Fuse 86.7/95.5 ——116.9/127.9 ——1/1 ——6/6 ——125/150 ——115/116 ——
EHK30AHCF
30 22.5 3 Fuse 62.6/69.2 ——86.8/95.0 ——3/3 ——8/8 ——90/100 ——97/98 ——
30 22.5 1 Fuse 109.0/120.0 ——144.8/158.5 ——0/00 ——6/6 ——150/175 ——117/150 ——
FIELD MULTIPOINT WIRING OR 24 AND 30 KW SINGLE PHASE
Heater Model
Heater kW
P
H
A
S
E
Heater Amps 208/230V
Minimum Circuit Ampacity
208/230V
Minimum Wire Size (AWG)
208/230V Min Gnd
Wire Size
208/230V
Max Fuse/Ckt Bkr Amps
208/230V
Max Wire Length 208/230V
(FT)
L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6 L1, L2 L3, L4 L5, L6230V208V
EHK25AHCF 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 36.2/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73
EHK30AHCF 30 22.5 1 36.2/40.0 36.2/40.0 36.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/6 8/8 8/8 10/10 60/60 50/50 50/50 78/80 59/59 59/59
Notes:
1 Copper wire must be used. If other than uncoated (non-plated), 75°C ambient, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National
Electric Code (ANSI/NFPA 70).
* When used with Fan Coil model sizes 2400, 3600.
** When used with Fan Coil model sizes 4800, 6000.
Includes blower motor amps of largest Fan Coil used with heater.
Supplied as single phase, field convertible to 3-phase.
Supplied as 3-phase, field convertible to single phase, single or multiple supply circuits.
Length shown is as measured one way along wire path between unit and service panel for a voltage drop not to exceed 2%.
PRODUCT SPECIFICATIONS Fan Coils: FVM4X
496 21 5104 03 11Specifications are subject to change without notice.
ACCESSORIES
Part Number Description Use with Model Sizes
EBAC01DSC Disconnect Kit use with All single phase Heaters
5 kW thru 10 kW
EBAC02NCB
Downflow Base Kit
2400B
EBAC03NCB 3600B, 4800B
EBAC04NCB 6000B
EBAC01DFS Downflow Conversion Kit − Slope Coil 3600B
EBAC02DFA Downflow Conversion Kit − “A” Coil 2400B, 4800B, 6000B
EBAC01SPK Single Point Wiring Kit only for use with 15 kW & 20 kW fused heaters
Square D part #
QOU14100JBAF
Single Point Wiring Kit − Square D
Jumper Bar Assembly
Only for use with
EHK15AKB and EHK20AKB breaker heaters
EBAC01FKM Filter Kit (washable, box of 12)
Factory Supplied
2400B
Factory SuppliedEBAC01FKL3600B, 4800B
EBAC01FKX 6000B
NASA00201FR Standard Filter Rack (16 x 20 x 1 filter required)2400B
NASA00301FR Standard Filter Rack (20 x 20 x 1 filter required)3600B, 4800B
NASA00401FR Standard Filter Rack [quantity 2]
(12 x 20 x 1 filter required)6000B
EBAC01PLG No Heat (Plug) Kit (box of 6)ALL
(Factory Installed)
EBAC01CTK PVC Condensate Trap Kit (box of 50)ALL
EBAC01GSK Horizontal/Downflow Gasket Kit ALL
(required for horizontal right and downflow)
NAEA20101TX
TXV Kit, R−22, Copper or Tin Coil Only
2400, 3600
NAEA20201TX 4800
NAEA20301TX 6000
NAEB20101TX
TXV Kit, R−22, Aluminum Coil Only
2400BL, 3600BL
NAEB20201TX 4800BL
NAEB20301TX 6000BL
1191140 Door Gasket Kit **ALL
** This kit is for replacement of factory installed gaskets if they are damaged or removed from the fan coil.
ELECTRIC HEATERS
Part Number Description Use with Model Sizes
EHK05AKN 5 kW, single phase, no internal circuit protection ALL
EHK05AKB 5 kW, single phase, with circuit breakers ALL
EHK07AKN 8 kW, single phase, no internal circuit protection ALL
EHK07AKB 8 kW, single phase, with circuit breakers ALL
EHK09AKCN 9 kW, supplied as single phase, field convertible to
3−phase, no internal circuit protection 3600B, 4800B, 6000B
EHK10AKN 10 kW, single phase, no internal circuit protection ALL
EHK10AKB 10 kW, single phase, with circuit breakers ALL
EHK15AKF 15 kW, single phase, with fuses ALL
EHK15AKB 15 kW, single phase, with circuit breakers ALL†
EHK15AHN 15 kW, 3−phase, no internal circuit protection ALL†
EHK18AHN 18 kW, 3−phase, no internal circuit protection 4800B, 6000B
EHK20AKF 20 kW, single phase, with fuses ALL†
EHK20AKB 20 kW, single phase, with circuit breakers ALL†
EHK25AHCF 24 kW, supplied as 3−phase, field convertible to
single phase, with fuses 4800B, 6000B
EHK30AHCF 30 kW, supplied as 3−phase, field convertible to
single phase, with fuses 4800B, 6000B
† 15kW & 20kW are not recommended for specific heat pump applications, see AIRFLOW DELIVERY (CFM)
PRODUCT SPECIFICATIONS Fan Coils: FVM4X
12 496 21 5104 03Specifications are subject to change without notice.
NOTES:
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−