Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 1 RIO DE PALMASFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sqft-) Insulation Area 6. Conditioned floor area above grade (ft2) 1306 a. Under Attic (Vented) R=30.0 1306.00 ft2 Conditioned floor area below grade (ft2) 0 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. N/A R= ft2 7. Windows(128.9 sqft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=1.02 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: Sgi, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 It Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area 2 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 b. EF: 0.600 b. Conservation features N/A R= ft2 None 16. Credits None Glass/Floor Area:0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this.'i�ESxf�� Code. calculation indicates compliance PREPARED BY:n'U with the Florida Energy Code. _ _ Before construction is completed ^'-�0� I this building will be inspected for a DATE: compliance with Section 553.908 Florida Statutes. _ �y ®� I hereby certify that this building, as designed i = ompliance with the Florida Energy Code'-- - OWNE AG€ T: BUILDING OFFICIAL: DATE!\\ DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 On for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUILLING-THE COTTAGE IMPACT Addresstype: Street Address Building Type: User Bedrooms: 1 Lot#: - Owner. WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: Total Stories: 1 PlatBook: - BuilderName: WYNNE BUILDING CORP. Worst Case: Yes Street THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County: St. Lucie Jurisdiction: CrossVenfilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE Design Temp Int Design Temp Heating Design Dailytemp JDesign Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13M76.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234It 0.473 - 0.00 1.00 0.00 -2 Slab -On -Grade Edge Ins DEN 24 0 144 ft 0.473 - 0.00 1.00 0.00 _ 3 Slab -On -Grade Edge Ins SINK AREA 7 0 42 ft 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 _ 5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452 ft OA73 - 0.00 1.00 0.00 _ 6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50 ft 0.473 - 0.00 1.00 0.00 _7 Slab -On -Grade Edge Ins POWDER 1 0 25ft 0.473 - 0.00 1.00 0.00 _8 Slab -On -Grade Edge Ins KITCHEN 38 0 232ft 0.473 - 0.00 1.00 0.00 _ 9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40 It OA73 - 0.00 1.00 0.00 10 Slab -On -Grade Edge Ins STORAGE 21 0 24 ft 0.304 - 0.00 0.00 1.00 677/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft2 0ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 150 1306 ft2 N N CEILING (Total Exposed Area = 1336 sq.ft.) # Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type _ 1 UnderAttic(Vented) MASTER BEDROOM 30.0 Blown 234.Oft- 0.053 0.10 Wood _2 UnderAttic(Vented) DEN 30.0 Blown 144.0ft 0.053 0.10 Wood _3 UnderAttic(Vertted) SINK AREA 30.0 Blown 42.0ft2 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.0R2 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.0ft2 0.053 0.10 Wood _6 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.Oft2 0.053 0.10 Wood _7 UnderAttic(Vented) POWDER 30.0 Blown 25.O112 0.053 0.10 Wood _8 UnderAttio(Vented) KITCHEN 30.0 Blown 232.02 0.053 0.10 Wood _9 UnderAttic(Vented) LAUNDRY 30.0 Blown 40.0ft2 0.053 0.10 Wood _ 10 UnderAttic(Vented) STORAGE 30.0 Blown 24.Oft2 0.030 0.11 Wood 11 Knee Wall(Verded) GREAT ROOM 19.0 Blown 30.02 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project"section on page 1. Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below V# Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 S=>N Exterior Conc. Blk- Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Conc. Blk -Int ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _ 3 N=>S Exterior Conc. Blk- Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc. Blk-Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _ 5 S=>N Exterior Conc. Blk - Int Ins SINK AREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _ 6 N=>S Exterior Conc. Bilk - Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _ 7 W=>E Exterior Conc. Blk- Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 - 0% _ 8 S=>N Exterior Conc. Blk - Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 NHS Exterior Conc. Blk - Int Ins KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _10 E=>W Exterior Conc. Sik-Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _ 11 S=>N Exterior Conc. Blk - Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _ 12 N=>S Exterior Conc. Blk- Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _ 13 N=>S Exterior Conc. Blk - Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 14 N=>S Exterior Conc. Blk- Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 N=>S Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height V# Omt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.Oft2 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) / Wall --Overhang-- # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.4ft- 1.0 ft 5 in 1.0 ft 5 in None None _ 2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft 1.0 It 5 in 1.0 ft 5 in None None _ 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 ft 5 in 1.0 ft 5 in None None _ 4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.0ft2 12.0 ft 0 in 1.0 It 5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.9ff2 1.0 ft 5 in 1.0 ft 5 in None None 6 E=>W 10 Metal Law-E Single Yes 1.02 0.26 N N 12.8ft2 1.0 ft 5 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space($) 1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft2 280 ft2 35 ft 8 ft 11 MASS # Mass Type Area Thickness FurnitureFraction Space _ 1 Defaulg81bs/sq.ft.) Oft O ft 0.30 MASTER BEDROOM _ 2 Default(81bs/sq.ft.) 0 ft2 0 ft 0.30 DEN _ 3 Default(8lbs/sq.fL) 0 ft' 0 ft 0.30 SINK AREA _4 Defauft(81bs/sq.ft.) 0 ft2 0 ft 0.30 CLOSET -5 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 GREAT ROOM _ 6 Default(8lbs/sq.ft.) 0 ft2 0 it 0.30 MASTER BATH _7 Default(8lbs/sq.ft.) Oft' Oft 0.30 POWDER S Default(8lbs/sq.ft.) O ft2 O ft 0.30 KITCHEN _9 Default(8 lbs/sq.ft.) Oft• Oft 0.30 LAUNDRY 10 Default(Slbs/sq.ft.) Oft' Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity -Geothermal HeatPump- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm _1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 6171202111:47:00 AM EnergyGauge®USA 7.0.00- FlaRes2020 FBC 7th Edition(2020) Compliant Software Page FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt FixtureFlow Pipe Ins. Pipe length 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS ---Supply— --Retum------- Air CFM 25 CFM 25 HVAC # VDuct # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 120 ft Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [] Feb [ ] Mar [ j Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [] Oct [x] Nov [X] Dec Venting [] Jan [] Feb [X] Mar [X] Apr [] May [] Jun [] Jul [] Aug [ ] Sep [X] Oct Pq Nov [] Dec Schedule: HERS 2006 Reference Hours VThemostat Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 _Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6f7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y Owner: WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General Acontinuous air barriershall be installed in the building envelope. Air-permeableinsulationshall requirements The exteriorthermal envelope containsa continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation forframed walls shall be installed in substantial contactand continuous alignmentwith the air barrier. Windows,skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, orcontinuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floorinsulation, insulation with a Class I vapor retarder with overlapping joints taped, shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and widng Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall onexteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Elecbicallphonebox The air barrier shall be installed behind electrical or on exteriorwalls communication boxes orair-sealed boxes shall be installed. HVAC register boot HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. THE COTTAGE,FT. PIERCE,FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 1 5. Is this a worst case? Yes 6. Conditioned floor area above grade (ft2) 1306 Conditioned floor area below grade (ft2) 0 7. Windows** Description Area a. U-Factor: Sgt. U=1.02 76.04 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgt, U=1.03 40.00 ftZ SHGC: SHGC=0.27 c. U-Factor: Sgt, U=1.02 12.85 ft2 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 8. Skylights Description Area U-Factor(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 b. N/A R= ft2 c. N/A R= ft2 10. Wall Types(1718.3 sqft.) Insulation Area a. Concrete Block- Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11,0 240.00 ft2 c. N/A R= ft2 d. N/A R= ft2 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. N/A R= ft2 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 29.0 SEER:14.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 27.0 HSPF:8.20 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.600 b. Conservation features None 16. Credits None certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: �� Z S)L C',City/FL Zip: FT. `PIIERCE,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Project Summary o: vurlghtsoft Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phore: 772466-6799 Email: OUICKCALCS@A0l-.CCM For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE. FL Notes: Design Information Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Ducts 4013 Btuh Duds 5251 Btuh Central vent (0 crm) 0 Btuh Central vent (0 dim) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20340 Btuh Use manufacturers data n Rate/swing multiplier Equipmeni 0.95 Infiltration sensible load 19734 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2094 Btuh Ducts 1524 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Cooiingg (none) (ft=) 1306 1306 Equipment latent load 3618 Btuh Volume (11F) 10579 10579 Air changesthour 0.45 0.23 Equipment Total Load (Sen+Lat) 23352 Btuh Equiv.AUF (dm) 79 41 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Canner Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3000GOA0 Cond CH14NBO3000GOA0 AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heatinglnput Sensible cooling 20300 Bluh Heating output 28000 Btuh @47°F Latentcooling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Btuh Actual air flow 967 dm Actual air flow 967 cfim Air flow factor 0.048 chVBtuh Airflowfador 0.047 cim/Biuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 OF Input=p5 kW, Output=18005 Btuh, 100AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. v�rrighlsQfC� RigfSJteGUnw,sa1201919.021 RSU08101 2021%lam121321:40 Page 1 ...\Wrig%oft FNACIWVNNESUIDLING-THECDTTAGEnp Calc=M16 Front Doorfaces: SW t{'- wright� Right-J® Worksheet .1017: Entire House °aW: QUICK CALCS, INC. ey 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phare: 772-466-6799 Em i:QUICKCALCS@AOL.COM 1 Room rlame Fs4re House MASTER BEDROOM 2 E)posadwall 145D it 31D It 3 Room height S1 ft 8.1 it heatlwol 4 Room dimensons 130 x 16D it 5 .Room area 1306.0 ft' 234D IF Ty Construction U-Value Or HTM Area Load Area number (BluhAF-°F) (ebw or perimeter (it) (BWh) or perimeter (it) (BWh) Heat Cool Gross NAPS Heat Cool Gross NIPS Heat Cool 6 W 13AAa s 0.143 n 4.00 2.19 446 427 1710 934 0 0 0 - 0 I—C 2glaang,drou1r, 1D40 n 29.12 21.68 18 0 537 400 0 0 0 0 13AA= 0.143 a 4.00 219 162 129 516 282 0 0 0 0 2&drig,droutr, 1D40 a 29.12 39.42 13 2 36B 498 0 0 0 0 11 111D0 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 tVN 13AAM 0.143 s 4D0 2-19 284 277 1107 605 146 146 584 319 2gWft droutr, 1D40 s 29.12 21M 7 7 202 150 0 0 0 0 _a 13A-4ocs 0.143 w 4.00 219 284 192 767 419 105 73 291 159 1Aclom 1270 w 3556 34.77 41 41 1451 1419 0 0 0 0 1A411om 1270 w 3556 61.76 18 3 656 1139 0 0 0 0 1A-h1om 1270 w 3556 63.40 33 5 1162 2072 33 5 1162 2072 C 16C-30ml ODM - 020 128 13D6 1306 1170 1672 234 -234 210 300 F 22A-tpl 0.969 - 27.69 ODO 1306 145 4015 0 234 31 858 0 6 a)AED eMursm 3591 997 Envelope lossgain 13885 13393 31D5 3847 12 a) Nitration 2441 068 522 w b) RoomventilAw 0 0 0 0 13 Intarnalgains O=PanS@ 230 2 460 0 0 Applianossrolher 1000 p Subtotal (lines6to 13) 16327 15522 3627 39W Lese>dBmal load 0 0 0 0 Lesttanser 0 0 0 0 Redistribution 0 0 0 0 14 SubbFal 16327 15522 3627 3990 15 Dudloads 25% 34% 4013 5251 25% 34% 892 1352 ToW room load 20340 20773 4518 5342 Air required (dm) 967 967 215 249 Calculations approved_byACCAto meet all requirements of Manual J Bth Ed c -4- .. RgF 9.021101 20214121321:40 iWA .\Wdgf6oRHJAgWYNNEBUIDLING-7HECOTrAGEAp CaIc=MI8 FrorrtDoorfasSW Page F wrightsofr Right-JO Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317ST. LUCIE LANE, FORT HEMS, FL34946 Phna: 772-466-6799 Email:QUICKCALCS AOL.COM 1 Room name DEN SPIKAREA 2 E1posedwall 24D It 7A it 3 Room height &7 It heaYmd &1 t heaYbod 4 5 Room dimensons Roan area 12D x 12.0 It 144.0 IF 6.0 x 7.0 It 420 ff Ty Consvction U-Ndu Or HTM Area (It) Load Area (P) Load number (BtuhMF°F) Ah4!'`) or penmetar (it) (Bluh) or perimeter (ft) (BWh) Heat Cool Gros NIPS Heat Cool Gros NIPS Heat Cod 6 W L--G 13A-4= 0.143 n 4A0 2.19 97 97 389 213 0 0 0 0 2glaang,croutr, 13AAM IA40 0.143 n a 29.12 4.00 21.68 219 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 20a2ing,drot&, 1A40 a 29.12 39A2 0 0 0 0 0 0 0 0 11 11130 0.390 a 10.92 1024 0 0 0 0 0 0 0 0 W �--C laAA s 2glaarg,droutr, 13A-4os 0.143 1.040 0.143 s s w 440 29.12 4.W 219 21M 219 0 0 97 0 0 79 0 0 315 0 0 172 57 0 0 57 0 0 227 0 0 124 0 0 IAolom tA411an 1270 1270 w w 35M 3535 34.77 61.76 0 18 0 3 0 656 0 1139 0 0 0 0 0 0 0 0 1Ahtom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C-30ml 01M - 0,90 128 144 144 129 184 42 42 38 54 F 2" 0.969 - 27.69 0.00 144 24 665 0 42 7 194 0 6 c)AED x urson 574 3 Envelope losstgain 2154 2283 459 175 12 a) Nitration 404 111 118 32 b) Roome filafion 0 0 0 0 13 hrtemalgaim O=pants@ 230 0 0 0 0 Appliancsbti 0 0 Subtotal 0ir1es6to 13) 2558 2394 576 207 Lessextemalload 0 0 0 0 Lestranger 0 0 0 0 14 Redistribuffon Subt#d 0 2558 0 2394 0 576 0 207 15 Dudloads 25% 34% 629 811 25% 34% 142 70 Total room load Air required (dm) 3187 152 3205 149 718 34 278 13 _Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed c wr4�hts4a'Ie` �rA .021 07 2021-Jo-121321:40 -.\WrigFoftHACWMWEBUI�JNG-TECOTiAGE.nLp CaIc=M1B FwtDoofacesSW Page 2 -�mightsoft, Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317ST. LUCIE LANE, FORTPIERCE, FL34946 Phom:772.466-6799 Email: QUICKCALCS@AOL.COM 1 Room name CLOSET GREAT ROOM 2 5posed Hall 0 ft 32.0 ft 3 Room height 8.1 ft heaUmol 8.1 ft heaV=l 4 Room dimensions 9.0 x 7.0 ft 1.0 x 452.0 R 5 Room area 63.0 T 452.0 IF Ty Construction U-value Or HTM Area ( Load Area (fe) Load number (aWhw- °� (Bfuh/ft=) or perimeter (R) (13Wh) or perimeter r (ft) (BWh) Heat Cool Grass WP/S Heat Cool Gros WP5 Heat Cool 6 VL-G 13A-4oa 0.143 n 4.00 2.19 0 0 0 0 178 160 640 350 2glaarg,droutr, 1.040 n 29.12 21.68 0 0 0 0 18 0 537 400 13A-4aas 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, droue, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 1100 0390 a 1092 1034 0 0 0 0 0 0 0 0 VL1M-4ors 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 -(3 2glazing,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13AAo s 0.143 w 4A0 2.19 0 0 0 0 81 40 161 88 1Aclom 1270 w 35S6 34.77 0 0 0 0 41 41 1451 1419 1A-h1om 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35M 63.40 0 0 0 0 0 0 0 0 C 16CJ0m1 0.032 - 0.90 128 63 63 56 81 452 452 405 579 F 22A4p1 0.989 - 27.69 0.00 63 0 0 0 452 32 am 0 6 c)AED excurson -1 2069 Envelopelossgain 56 80 4080 4903 12 a) Infiltratian 0 0 539 148 b) Room ventilation 0 0 0 0 13 Inbamalgains O¢vparrs@ 230 0 0 2 460 Appliancs(ather 0 0 Subtotal(iines6to 13) 56 80 4619 5511 Lesexdemalload 0 0 0 0 Lestransfer 0 0 0 0 Redistnbution 0 0 0 0 141 Subtotal 56 80 4619 5511 151 Dudloads 25% 34% 14 27 25% 349/6 1135 1868 Total room load 70 107 5754 7179 Airrequired (dm) 3 5 274 1 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wr�9htsof!^ Rigtd919.021RSU08101 2021-JaM21321AOc_.\WdgF6oftUACWVNEBUIDLING-THECOTAGE.rup Glc=rUB FmrtWorao:sSW Page al -� wrightsoft° Right-JO Worksheet Jab: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: T2466-6799 Emall:QUICKCALCS@AOL.COM 1 Room name MASTER BATH POWDER 2 Exposedwall 5D ft 0 ft 3 Roan height 8.1 ft healmol 8.1 It heatbool 4 Room dimensons Mo x 6.0 ft 5.0 x 5.0 ft 5 Room area 50.0 1F 25.0 IF Ty Construction U-value Or HTM Area (ff) Load Area Load number (BG1h4F-°Fj (BWhfll� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gros N/P/S Heat Cool Gros NIPS Heat Cool 6 vd 13A-0as 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 �G 2glaarg,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4ors 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glaang,croulr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 D 11D0 0.390 a 1092 10.34 0 0 0 0 0 0 0 0 W 13A4c s 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 —G 2glaang,droutr, 1.040 s 29.12 21.68 7 7 202 150 0 0 0 0 13A-0ws 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Aciom 1270 w 3556 34.77 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 IA-hlom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 128 50 50 45 64 25 25 22 32 F 22A-tpI 0.989 - 27.69I 0.00 I 50 5 138 0 25 0 0 0 6 c)AED excursion y 0 Envelope los/gain 520 284 221 32 12 a) Infiltration 84 23 0 0 b) Roomventlafion 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 0 0 Appliancesrolher I 0 0 Subtotal(linestito13) 6134 307 1 22 32 Leseremalload 0 0 0 0 Lesstransfer 0 0 0 0 Redishibufion I 0 01 0 0 14 Subtotal 604 307 22 32 15 Duct loads 25% 34% 148 104 25"/ 34% 61 11 Total room load 752 411 28 42 Airrequired (cfm) 36 19 1 2 Calculabons approved bvACCAtO meet all requirements of Manual J 8th Ed -rid- mtr!o _ 2021 Jan121321:40 �^`A RigkSuteGUriversa1201919.021 RSW8101 Page 4 ...\Wdgta=oft FNAC\WYNNEBUIDLING-THECOTTAGE.np CaIc=W8 Frort Coorlaws:SW wrightsoft- Right-J@ Worksheet ,lob. Entire House By. QUICK CALCS, INC. By. 317ST. LUCIE LANE, FORTPIERCE, FL34946 Phore:772466-6799 Email:OUICKCALCS@AOLCOM 1 Room name KITCHEN LAUNDRY 2 Emo.ed wall 38.0 ft 0 ft 3 Room height 8.1 it heatmol 8.1 it heaV=l 4 Room dimensions 1.0 x 232,0 ft 4.0 x 10.0 ft 5 Room area 232.0 fF 40.0 iF Ty Construction U-value Or HTM Area ([F) Load Area (in Load number I (BWh&[ F) (BWh/fl or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat I Cool Gros NIPS Heat Cool Gros NIPS Heat Cool 6 Yil 13A-4ocs 0.143 n 4.00 219 138 138 551 301 0 0 0 0 --G 2glaang,droutr, 1A40 n 29.12 21.68 0 0 0 0 0 0 0 0 13AAors 0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 2giaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 D 11DO 0.390 a 10.92 10,34 20 20 223 211 0 0 0 0 VN 13AA= 0.143 s 4A0 2.19 41 41 162 89 0 0 0 0 t-G 2glaang,droutr, 1A40 s 29.12 21.68 0 0 0 0 0 0 0 0 13A4o s 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-dom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-htom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 IA-htom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 128 232 232 208 297 40 40 36 51 F 22A-ipl 0.989 - 27.69 0.00 232 38 1052 0 40 0 0 0 6 c)AED e=urson -37 -1 Envelope losagain 2951 1570 36 51 12 a) Infiltralion 640 175 0 0 b) RoomvenAlaton 0 0 0 0 13 Internal gains: Ooolpans@ 230 0 0 0 0 Applianre,4olher 1000 0 Subbtal(lines6W13) 3591 2745 36 51 Lesezdemal load 0 0 0 0 Less transfer 0 0 0 0 Redishibuton 0 0 0 0 14 SubWml 3591 2745 36 51 15 Duct loads 1 25% 34% 883 931 25% 34% 9 17 Total mom load 4474 3676 68 Air required;Qm) 213 177 2 3 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 9&-r ld- ,a�� ... RgkSuR919.021 RSU08101 2021-JarFl 21321:40 Wdg6HAQWNNEBUDLING-THECOTCAGE.ruo CIc=MJB FrortOooraresSW Page wrightsoftRight-JM Worksheet Jab: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466£799 Email: QUICKCALCSa@AOL.COM 1 Room name STORAGE 2 Eposedwall 8.0 it 3 Room height 8.1 It heaVmol 4 Rwm dimensions 4.0 x 6.0 it 5 Room area 24.0 1F Ty Construction U-value Or HTM Area (II') Load Area Load number (BtuhHF°r7 (BWtdR or perimeter (fi) (BWh) or perimeter Heat Cool Gros N/P/S Heat Cool Gross N/P/S Heat Cool 6 Yr/ 13A4= 0.143 n 4.00 2.19 32 32 130 71 �—f 2glazing. dr outr, 1.040 In 29.12 21.68 0 0 0 0 13A4or_s 0.143 a 4.00 2.19 32 32 130 71 2glaang,droutr, 1.040 a 29.12 39A2 0 0 0 0 11 11DO 0390 a 1092 10.34 0 0 0 0 t—G 13A4as 0.143 s 4.00 2.19 0 0 0 0 2glazing, droutr, 1.040 s 29.12 21.68 0 0 0 0 13A4os 0.143 w 4.00 2.19 0 0 0 0 1A-dom 1270 w 3556 34.77 0 0 0 0 1Xh1om 1270 w 35.56 61.76 0 0 0 0 1A-Mom 1270 w 35.56 63.40 0 0 0 0 C 161330ml 0.032 - 0.90 128 24 24 22 31 F 22A-tll 0.989 - 27.69 I 0.00 24 8 222 0 6 c)AED imurson 3 Envelopeloss/gain 502 170 12 a) Infiltration 135 37 b) Room venfilabon 0 0 13 Internal gains: Oovpants@ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 637 207 Les exam.] load 0 0 Lestrarder 0 0 Redistribution 0 0 141 Subtotal 637 207 15 Ductloads 25% 29% 157 60 Total room load 794 266 Air required(Um) 38 12 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed �F► wrtglaLsoT!' AC0KRigtiSuteC�llrnersa1201979.021 RSU06107 Page6 .lW2021-Jarv121321:40 ..righboltHVAQWYNNEBUIDLING-THECO17AGE.rnp Calc=M18 Fmi-tCoorfaces:SW Duct System Summary Job: wrightsoft® y ry Date: Entire House BY QUICK CALCS, INC. 317ST. LUCIE LANE, FORTPIERCE, FL34946 P1nfe: 77246&6799 Email: QUICKCALCS@AOL.COM I Project Information For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 022 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 dim 126 Supply Branch Detail Table Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cbn Name Design (Btuh) Htg (CFm) Clg (dm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (it) Ftg.Egv Ln (ft) Trunk CLOSET C 107 3 5 0.080 4.0 Ox0 VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO VIFx 33.5 90.0 st1 GREAT ROOM c 3689 137 172 0.080 8.0 Ox0 VIFx 14.6 70.0 GREATROOM-A c 3689 137 172 0.080 8.0 Ox0 VIFx 16.1 70.0 KITCHEN h 4474 213 171 0.080 7.0 OxO VIFx 4.5 70.0 LAUNDRY c 68 2 3 0.080 4.0 Ox0 VIFx 5.4 70.0 MASTERBAiFi h 752 36 19 0.080 4.0 OxO VIFx 32.9 90.0 SO MASTERBEDROOM c 2671 107 124 0.080 7.0 OxO VIFx 27.9 90.0 st1 MASTER BEDROOM -A C 2671 107 124 0.080 7.0 OxO VIFx 35.9 90.0 st1 POWDER C 42 1 2 0.080 4.0 Ox0 VIFx 292 90.0 st1 SINKAREA h 718 34 13 0.080 4.0 Ox0 VIFx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 Ox0 VIFx 11.2 70.0 Name Trunk Type Htg (dm) Clg (cim) Design FR Veloc (fpm) Diam (in) H x W (in) Dud Material Trunk st1 PeakAVF 441 437 0,08 5561 12.0 0 x 0 VinIFIX Wright soft® 2021-Jarv121321:41 A •W+-� w��.-, Rgk-Suk&Uriwrs1201919.021RSU08101 Paget ...1Wngt6ofl HJAaWYNNEBUIDLING-THECOTTAGE. Calc=MJ6 %tDoor%.:SW Name Grille Size (in) Htg (Cfm) Clg (Cfm) TEL (ft) Design FR Veloc (ipm) Diam (in) H x W (in) Stud/Joist Opening (in) Dud Mat Trunk rbl Ox0 967 967 0 0 0 0 Ox 0 MFx wrightsoft" 2021Jar 121321:41 •..+�• �..m+�-o..� RigKSute@Unversa120t919.027 RSU08101 Page ...Wnghbo HJADWYNNEBUIDLING-THECOTTAGE.np Calc=MJB Frort Doorfaces:SW