HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 1 RIO DE PALMASFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Types(1718.3 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0 240.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
1
d. N/A
R= ft2
5. Is this a worst case?
Yes
11. Ceiling Types(1336.0 sqft-)
Insulation Area
6. Conditioned floor area above grade (ft2)
1306
a. Under Attic (Vented)
R=30.0 1306.00 ft2
Conditioned floor area below grade (ft2)
0
b. Knee Wall (Vented)
R=19.0 30.00 ft2
c. N/A
R= ft2
7. Windows(128.9 sqft.) Description
Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Sgl, U=1.02
76.04 ft2
a. a. Sup: Attic, Ret: Attic, AH:
Attic 6 120
SHGC: SHGC=0.29
b.
b. U-Factor: Sgl, U=1.03
40.00 ft2
C.
SHGC: SHGC=0.27
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: Sgi, U=1.02
12.85 ft2
a. Central Unit
29.0 SEER:14.00
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
4.701 It
Area Weighted Average SHGC:
0.281
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description
Area
a. Electric Heat Pump
27.0 HSPF:8.20
U-Factor:(AVG) N/A
N/A ft2
SHGC(AVG): N/A
9. Floor Types Insulation
Area 2
15. Hot Water Systems
a. ElectricTankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation R= 0.0
1306.00 ft2
b.
EF: 0.600
b. Conservation features
N/A R=
ft2
None
16. Credits
None
Glass/Floor Area:0.099 Total Proposed Modified Loads: 41.30
Total Baseline Loads: 43.21
PASS
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this.'i�ESxf��
Code.
calculation indicates compliance
PREPARED BY:n'U
with the Florida Energy Code.
_
_
Before construction is completed
^'-�0� I
this building will be inspected for
a
DATE:
compliance with Section 553.908
Florida Statutes.
_
�y
®�
I hereby certify that this building, as designed i = ompliance
with the Florida Energy Code'--
-
OWNE AG€ T:
BUILDING OFFICIAL:
DATE!\\
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 On for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUILLING-THE COTTAGE IMPACT
Addresstype:
Street Address
Building Type: User
Bedrooms: 1
Lot#:
-
Owner. WYNNE BUILDING CORP.
Conditioned Area: 1306
Block/SubDivision:
Total Stories: 1
PlatBook:
-
BuilderName: WYNNE BUILDING CORP.
Worst Case: Yes
Street
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
Rotate Angle: 180
County:
St. Lucie
Jurisdiction:
CrossVenfilation: No
City, State, Zip:
FT. PIERCE,
Family Type: Detached
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
YearConstruct:
Shielding: Suburban
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design
Dailytemp
JDesign
Location
Tmy Site
97.5% 2.5%
Winter Summer
Degree Days
Moisture
Range
FL, Fort Pierce
FL VERO_BEACH_MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
13M76.2001953125
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled
Heated
_ 1 MASTER BEDROOM
234
1895.4 No 0
1
Yes
Yes
Yes
_2 DEN
144
1166.4 No 0
Yes
Yes
Yes
_3 SINK AREA
42
340.2 No 0
Yes
Yes
Yes
_4 CLOSET
63
510.3 No 0
No
Yes
Yes
_5 GREAT ROOM
452
3661.2 No 2
Yes
Yes
Yes
_6 MASTER BATH
50
405 No 0
Yes
Yes
Yes
_7 POWDER
25
202.5 No 0
No
Yes
Yes
_8 KITCHEN
232
1879.2 Yes 0
Yes
Yes
Yes
_9 LAUNDRY
40
324 No 0
No
Yes
Yes
10 STORAGE
24
192 No 0
0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1306 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Ins
MASTER BEDROOM 31 0
234It 0.473
-
0.00
1.00 0.00
-2 Slab -On -Grade Edge Ins
DEN
24 0
144 ft 0.473
-
0.00
1.00 0.00
_ 3 Slab -On -Grade Edge Ins
SINK AREA
7 0
42 ft 0.473
-
0.00
1.00 0.00
_4 Slab -On -Grade Edge Ins
CLOSET
1 0
63ft 0.473
-
0.00
1.00 0.00
_ 5 Slab -On -Grade Edge Ins
GREAT ROOM
32 0
452 ft OA73
-
0.00
1.00 0.00
_ 6 Slab -On -Grade Edge Ins
MASTER BATH
5 0
50 ft 0.473
-
0.00
1.00 0.00
_7 Slab -On -Grade Edge Ins
POWDER
1 0
25ft 0.473
-
0.00
1.00 0.00
_8 Slab -On -Grade Edge Ins
KITCHEN
38 0
232ft 0.473
-
0.00
1.00 0.00
_ 9 Slab -On -Grade Edge Ins
LAUNDRY
1 0
40 It OA73
-
0.00
1.00 0.00
10 Slab -On -Grade Edge Ins
STORAGE
21 0
24 ft 0.304
-
0.00
0.00 1.00
677/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
Roof Gable Roof
Red Solar SA Emitt Emitt
Deck Pitch
Type
Materials Area Area Color
Barr Absor. Tested
Tested
Insul. (deg)
1 Hip
Metal 1376 ft2 0ft2 Light
N
0.6 No
0.9 No
0 18.4
ATTIC
# Type
Ventilation Vent Ratio (1 in) Area
FIBS IRCC
1 Full attic
Vented 150 1306 ft2
N
N
CEILING
(Total Exposed Area = 1336 sq.ft.)
# Ceiling Type
Space R-Value Ins.Type
Area
U-Factor Framing Frac.
Truss Type
_ 1 UnderAttic(Vented)
MASTER BEDROOM 30.0 Blown
234.Oft-
0.053
0.10
Wood
_2 UnderAttic(Vented)
DEN 30.0 Blown
144.0ft
0.053
0.10
Wood
_3 UnderAttic(Vertted)
SINK AREA 30.0 Blown
42.0ft2
0.053
0.10
Wood
_4 UnderAttic(Vented)
CLOSET 30.0 Blown
63.0R2
0.053
0.10
Wood
_5 UnderAttic(Vented)
GREAT ROOM 30.0 Blown
452.0ft2
0.053
0.10
Wood
_6 UnderAttic(Vented)
MASTER BATH 30.0 Blown
50.Oft2
0.053
0.10
Wood
_7 UnderAttic(Vented)
POWDER 30.0 Blown
25.O112
0.053
0.10
Wood
_8 UnderAttio(Vented)
KITCHEN 30.0 Blown
232.02
0.053
0.10
Wood
_9 UnderAttic(Vented)
LAUNDRY 30.0 Blown
40.0ft2
0.053
0.10
Wood
_ 10 UnderAttic(Vented)
STORAGE 30.0 Blown
24.Oft2
0.030
0.11
Wood
11 Knee Wall(Verded)
GREAT ROOM 19.0 Blown
30.02
0.045
0.11
Wood
WALLS
(Total Exposed Area = 1718 sq.ft.)
Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project"section on page 1.
Adjacent
Cavity Width
Height
Area U-
Sheath Frm.
Solar Below
V# Omt To
Wall Type
Space R-Value Ft In
Ft In
sq.ft. Factor
R-Value Frac.
Absor. Grade
_ 1 S=>N Exterior
Conc. Blk- Int Ins
MASTER BEDROOM 4.1 18.0 0
8.0 1
145.5 0.149
0 0
0.30 0%
_2 W=>E Exterior
Conc. Blk -Int ins
MASTER BEDROOM 4.1 13.0 0
8.0 1
105.1 0.149
0 0
0.30 0%
_ 3 N=>S Exterior
Conc. Blk- Int Ins
DEN 4.1 12.0 0
8.0 1
97.0 0.149
0 0
0.30 0%
_4 W=>E Exterior
Conc. Blk-Int Ins
DEN 4.1 12.0 0
8.0 1
97.0 0.149
0 0
0.30 0%
_ 5 S=>N Exterior
Conc. Blk - Int Ins
SINK AREA 4.1 7.0 0
8.0 1
56.6 0.149
0 0
0.30 0%
_ 6 N=>S Exterior
Conc. Bilk - Int Ins
GREAT ROOM 4.1 22.0 0
8.0 1
177.8 0.149
0 0
0.30 0%
_ 7 W=>E Exterior
Conc. Blk- Int Ins
GREAT ROOM 4.1 10.0 0
8.0 1
80.8 0.149
0 0
0.30 - 0%
_ 8 S=>N Exterior
Conc. Blk - Int Ins
MASTER BATH 4.1 5.0 0
8.0 1
40.4 0.149
0 0
0.30 0%
_9 NHS Exterior
Conc. Blk - Int Ins
KITCHEN 4.1 17.0 0
8.0 1
137.4 0.149
0 0
0.30 0%
_10 E=>W Exterior
Conc. Sik-Int Ins
KITCHEN 4.1 16.0 0
8.0 1
129.3 0.149
0 0
0.30 0%
_ 11 S=>N Exterior
Conc. Blk - Int Ins
KITCHEN 4.1 5.0 0
8.0 1
40.4 0.149
0 0
0.30 0%
_ 12 N=>S Exterior
Conc. Blk- Int Ins
KITCHEN 4.1 35.0 0
8.0 1
282.9 0.149
0 0
0.30 0%
_ 13 N=>S Exterior
Conc. Blk - Int Ins
STORAGE 4.1 6.0 0
8.0 0
48.0 0.149
0 0
0.30 0%
_ 14 N=>S Exterior
Conc. Blk- Int Ins
STORAGE 4.1 5.0 0
8.0 0
40.0 0.149
0 0
0.30 0%
15 N=>S Garage
Frame - Wood
MASTER BEDROOM 11.0 30.0 0
8.0 0
240.0 0.092
0 0.23
0.30 0%
DOORS
(Total Exposed Area = 20 sq.ft.)
Width
Height
V# Omt Adjacent To
Door Type
Space Storms
U-Value
Ft In
Ft In
Area
1 E=>W
Insulated
KITCHEN None
0.32
3.00 0
6.00 8
20.Oft2
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
(Total Exposed Area = 129 sq.ft.)
/ Wall
--Overhang--
# Omt ID Frame
Panes
NFRC U-Factor SHGC Imp Storm Area
Depth Separation Interior Shade
Screening
-1 W=>E 2 Metal
Low-E Single
Yes 1.02
0.29 N N 32.4ft-
1.0 ft 5 in 1.0 ft 5 in None
None
_ 2 W=>E 4 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4ft
1.0 It 5 in 1.0 ft 5 in None
None
_ 3 N=>S 6 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4ft2
1.0 ft 5 in 1.0 ft 5 in None
None
_ 4 W=>E 7 Metal
Low-E Single
Yes 1.03
0.27 N N 40.0ft2
12.0 ft 0 in 1.0 It 5 in None
None
-5 S=>N 8 Metal
Low-E Single
Yes 1.02
0.29 N N 6.9ff2
1.0 ft 5 in 1.0 ft 5 in None
None
6 E=>W 10 Metal
Law-E Single
Yes 1.02
0.26 N N 12.8ft2
1.0 ft 5 in 1.0 ft 5 in None
None
INFILTRATION
# Scope Method
SLA
CFM50 ELA EgLA
ACH ACH50 Space($)
1 Wholehouse Proposed ACH(50)
0.00026
881 48.35 90.78
0.0907 5.0 All
GARAGE
# Floor Area
Roof Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 280 ft2
280 ft2
35 ft
8 ft 11
MASS
# Mass Type
Area
Thickness FurnitureFraction Space
_ 1 Defaulg81bs/sq.ft.)
Oft
O ft
0.30 MASTER BEDROOM
_ 2 Default(81bs/sq.ft.)
0 ft2
0 ft
0.30 DEN
_ 3 Default(8lbs/sq.fL)
0 ft'
0 ft
0.30 SINK AREA
_4 Defauft(81bs/sq.ft.)
0 ft2
0 ft
0.30 CLOSET
-5 Default(8lbs/sq.ft.)
0 ft2
0 ft
0.30 GREAT ROOM
_ 6 Default(8lbs/sq.ft.)
0 ft2
0 it
0.30 MASTER BATH
_7 Default(8lbs/sq.ft.)
Oft'
Oft
0.30 POWDER
S Default(8lbs/sq.ft.)
O ft2
O ft
0.30 KITCHEN
_9 Default(8 lbs/sq.ft.)
Oft•
Oft
0.30 LAUNDRY
10 Default(Slbs/sq.ft.)
Oft'
Oft
0.30 STORAGE
HEATING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency Capacity -Geothermal HeatPump- Ducts
Block
kBtu/hr Entry Power Volt Current
1 Electric Heat Pump
Split/Single
HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1
1
COOLING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency
Capacity Air Flow SHR Duct
Block
kBtu/hr cfm
_1 Central Unit
Split/Single
SEER:14.0 29.0 0 0.80 sys#1
1
6171202111:47:00 AM EnergyGauge®USA 7.0.00- FlaRes2020 FBC 7th Edition(2020) Compliant Software Page
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
FixtureFlow Pipe Ins.
Pipe length
1 Electric
Tankless
Garage
0.60 (0.60) 1.00 gal 61 gal
120 deg
Standard
None
82
Recirculation
Recirc
Control
Loop Branch Pump DWHR
Facilities Equal DWHR
Other Credits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA NA
None
DUCTS
---Supply—
--Retum-------
Air
CFM 25 CFM 25
HVAC #
VDuct
# Location
R-Value Area Location R-Value Area Leakage Type
Handler
TOT OUT
QN
RLF Heat Cool
1 Attic
6.0 120 ft
Attic
6.0 45 ft' Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling [ ] Jan
[] Feb
[ ] Mar
[ j Apr
[ ] May [X] Jun [X] Jul
[X] Aug
[X] Sep [] Oct
[ ]
Nov [ ] Dec
Heating [X] Jan
[X] Feb
[X] Mar
[ ] Apr
[ ] May [ ] Jun [ ] Jul
[ ] Aug
[ ] Sep [] Oct
[x] Nov [X] Dec
Venting [] Jan
[] Feb
[X] Mar
[X] Apr
[] May [] Jun [] Jul
[] Aug
[ ] Sep [X] Oct
Pq Nov [] Dec
Schedule: HERS 2006 Reference
Hours
VThemostat
Schedule Type
1
2
3 4 5 6
7
8 9
10
11 12
_Cooling(WD)
AM
78
78
78 78 78 78
78
78 78
78
78 78
PM
78
78
78 78 78 78
78
78 78
78
78 78
_ Cooling (WEH)
AM
78
78
78 78 78 78
78
78 78
78
78 78
PM
78
78
78 78 78 78
78
78 78
78
78 78
Heating (WD)
AM
68
68
68 68 68 68
68
68 68
68
68 68
PM
68
68
68 68 68 68
68
68 68
68
68 68
Heating (WEH)
AM
68
68
68 68 68 68
68
68 68
68
68 68
PM
68
68
68 68 68 68
68
68 68
68
68 68
6f7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
Y
Owner: WYNNE BUILDING CORP. Jurisdiction: U
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
Acontinuous air barriershall be installed in the building envelope.
Air-permeableinsulationshall
requirements
The exteriorthermal envelope containsa continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exterior thermal envelope insulation forframed walls
shall be installed in substantial contactand
continuous alignmentwith the air barrier.
Windows,skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, orcontinuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead of floorinsulation, insulation
with a Class I vapor retarder with overlapping joints taped,
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garageseparation
Air sealing shall be provided between the garage and
conditionedspaces.
Recessedlighting
Recessed light fixtures installed in the building thermal
Recessed light fixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and widng
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers
Exterior walls adjacent to showers and tubs shall
onexteriorwall
and tubs shall separate them from the showers and tubs.
beinsulated.
Elecbicallphonebox
The air barrier shall be installed behind electrical or
on exteriorwalls
communication boxes orair-sealed boxes shall be installed.
HVAC register boot
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire sprinklers shall only
sprinklers
be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
THE COTTAGE,FT. PIERCE,FL,
1. New construction or existing New (From Plans)
2. Single family or multiple family
Detached
3. Number of units, if multiple family
1
4. Number of Bedrooms
1
5. Is this a worst case?
Yes
6. Conditioned floor area above grade (ft2)
1306
Conditioned floor area below grade (ft2)
0
7. Windows** Description
Area
a. U-Factor: Sgt. U=1.02
76.04 ft2
SHGC: SHGC=0.29
b. U-Factor. Sgt, U=1.03
40.00 ftZ
SHGC: SHGC=0.27
c. U-Factor: Sgt, U=1.02
12.85 ft2
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
4.701 ft
Area Weighted Average SHGC:
0.281
8. Skylights Description
Area
U-Factor(AVG) N/A
N/A ft2
SHGC(AVG): N/A
9. Floor Types Insulation
Area
a. Slab -On -Grade Edge Insulation R= 0.0
1306.00 ft2
b. N/A R=
ft2
c. N/A R=
ft2
10.
Wall Types(1718.3 sqft.)
Insulation
Area
a. Concrete Block- Int Insul, ExteriorR=4.1
1478.30 ft2
b. Frame - Wood, Adjacent
R=11,0
240.00 ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
11.
Ceiling Types(1336.0 sqft.)
Insulation
Area
a. Under Attic (Vented)
R=30.0
1306.00 ft2
b. Knee Wall (Vented)
R=19.0
30.00 ft2
c. N/A
R=
ft2
12.
Ducts, location & insulation level
R ft2
a. a. Sup: Attic, Ret: Attic, AH: Attic
6 120
b.
C.
13.
Cooling Systems
kBtu/hr
Efficiency
a. Central Unit
29.0 SEER:14.00
14.
Heating Systems
kBtu/hr
Efficiency
a. Electric Heat Pump
27.0
HSPF:8.20
15. Hot Water Systems
a. ElectricTankless Cap: 1 gallons
EF: 0.600
b. Conservation features
None
16. Credits None
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: �� Z S)L C',City/FL Zip: FT. `PIIERCE,FL,
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
® Project Summary o:
vurlghtsoft Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phore: 772466-6799 Email: OUICKCALCS@A0l-.CCM
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE. FL
Notes:
Design Information
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grAb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 16327
Btuh
Structure
15522
Btuh
Ducts 4013
Btuh
Duds
5251
Btuh
Central vent (0 crm) 0
Btuh
Central vent (0 dim)
0
Btuh
none
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 20340
Btuh
Use manufacturers data
n
Rate/swing multiplier
Equipmeni
0.95
Infiltration
sensible load
19734
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2094
Btuh
Ducts
1524
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg
Area
Cooiingg
(none)
(ft=) 1306
1306
Equipment latent load
3618
Btuh
Volume (11F) 10579
10579
Air changesthour 0.45
0.23
Equipment Total Load (Sen+Lat)
23352
Btuh
Equiv.AUF (dm) 79
41
Req. total capacity at 0.70 SHR
2.3
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Canner
Make Carrier
Trade CARRIER
Trade CARRIER
Model CH14NBO3000GOA0
Cond CH14NBO3000GOA0
AHRI ref 9162387
Coil FX4DNBO43L
AHRI ref 9162387
Efficiency 8.2 HSPF
Efficiency 11.5 EER,14
SEER
Heatinglnput
Sensible cooling
20300
Bluh
Heating output 28000
Btuh @47°F
Latentcooling
8700
Btuh
Temperature rise 26
OF
Total cooling
29000
Btuh
Actual air flow 967
dm
Actual air flow
967
cfim
Air flow factor 0.048
chVBtuh
Airflowfador
0.047
cim/Biuh
Static pressure 0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.85
Capacity balance point = 34 OF
Input=p5 kW, Output=18005 Btuh, 100AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
v�rrighlsQfC� RigfSJteGUnw,sa1201919.021 RSU08101 2021%lam121321:40
Page 1
...\Wrig%oft FNACIWVNNESUIDLING-THECDTTAGEnp Calc=M16 Front Doorfaces: SW
t{'- wright� Right-J® Worksheet .1017:
Entire House °aW:
QUICK CALCS, INC. ey
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phare: 772-466-6799 Em i:QUICKCALCS@AOL.COM
1
Room rlame
Fs4re House
MASTER BEDROOM
2
E)posadwall
145D it
31D It
3
Room height
S1 ft
8.1 it heatlwol
4
Room dimensons
130 x 16D it
5
.Room area
1306.0 ft'
234D IF
Ty
Construction
U-Value
Or
HTM
Area
Load
Area
number
(BluhAF-°F)
(ebw
or perimeter (it)
(BWh)
or perimeter (it)
(BWh)
Heat
Cool
Gross
NAPS
Heat
Cool
Gross
NIPS
Heat
Cool
6
W
13AAa s
0.143
n
4.00
2.19
446
427
1710
934
0
0
0
- 0
I—C
2glaang,drou1r,
1D40
n
29.12
21.68
18
0
537
400
0
0
0
0
13AA=
0.143
a
4.00
219
162
129
516
282
0
0
0
0
2&drig,droutr,
1D40
a
29.12
39.42
13
2
36B
498
0
0
0
0
11
111D0
0.390
a
10.92
10.34
20
20
223
211
0
0
0
0
tVN
13AAM
0.143
s
4D0
2-19
284
277
1107
605
146
146
584
319
2gWft droutr,
1D40
s
29.12
21M
7
7
202
150
0
0
0
0
_a
13A-4ocs
0.143
w
4.00
219
284
192
767
419
105
73
291
159
1Aclom
1270
w
3556
34.77
41
41
1451
1419
0
0
0
0
1A411om
1270
w
3556
61.76
18
3
656
1139
0
0
0
0
1A-h1om
1270
w
3556
63.40
33
5
1162
2072
33
5
1162
2072
C
16C-30ml
ODM
-
020
128
13D6
1306
1170
1672
234
-234
210
300
F
22A-tpl
0.969
-
27.69
ODO
1306
145
4015
0
234
31
858
0
6
a)AED eMursm
3591
997
Envelope lossgain
13885
13393
31D5
3847
12
a) Nitration
2441
068
522
w
b) RoomventilAw
0
0
0
0
13
Intarnalgains O=PanS@ 230
2
460
0
0
Applianossrolher
1000
p
Subtotal (lines6to 13)
16327
15522
3627
39W
Lese>dBmal load
0
0
0
0
Lesttanser
0
0
0
0
Redistribution
0
0
0
0
14
SubbFal
16327
15522
3627
3990
15
Dudloads
25%
34%
4013
5251
25%
34%
892
1352
ToW room load
20340
20773
4518
5342
Air required (dm)
967
967
215
249
Calculations approved_byACCAto meet all requirements of Manual J Bth Ed
c -4-
.. RgF 9.021101 20214121321:40
iWA .\Wdgf6oRHJAgWYNNEBUIDLING-7HECOTrAGEAp CaIc=MI8 FrorrtDoorfasSW Page
F wrightsofr Right-JO Worksheet Job:
Entire House Date:
By.
QUICK CALCS, INC.
317ST. LUCIE LANE, FORT HEMS, FL34946 Phna: 772-466-6799 Email:QUICKCALCS AOL.COM
1
Room name
DEN
SPIKAREA
2
E1posedwall
24D It
7A it
3
Room height
&7 It heaYmd
&1 t heaYbod
4
5
Room dimensons
Roan area
12D x 12.0 It
144.0 IF
6.0 x 7.0 It
420 ff
Ty
Consvction
U-Ndu
Or
HTM
Area (It)
Load
Area (P)
Load
number
(BtuhMF°F)
Ah4!'`)
or penmetar (it)
(Bluh)
or perimeter (ft)
(BWh)
Heat
Cool
Gros
NIPS
Heat
Cool
Gros
NIPS
Heat
Cod
6
W
L--G
13A-4=
0.143
n
4A0
2.19
97
97
389
213
0
0
0
0
2glaang,croutr,
13AAM
IA40
0.143
n
a
29.12
4.00
21.68
219
0
0
0
0
0
0
0
0
0
0
0
0
0
0
- 0
0
20a2ing,drot&,
1A40
a
29.12
39A2
0
0
0
0
0
0
0
0
11
11130
0.390
a
10.92
1024
0
0
0
0
0
0
0
0
W
�--C
laAA s
2glaarg,droutr,
13A-4os
0.143
1.040
0.143
s
s
w
440
29.12
4.W
219
21M
219
0
0
97
0
0
79
0
0
315
0
0
172
57
0
0
57
0
0
227
0
0
124
0
0
IAolom
tA411an
1270
1270
w
w
35M
3535
34.77
61.76
0
18
0
3
0
656
0
1139
0
0
0
0
0
0
0
0
1Ahtom
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
C
16C-30ml
01M
-
0,90
128
144
144
129
184
42
42
38
54
F
2"
0.969
-
27.69
0.00
144
24
665
0
42
7
194
0
6
c)AED x urson
574
3
Envelope losstgain
2154
2283
459
175
12
a) Nitration
404
111
118
32
b) Roome filafion
0
0
0
0
13
hrtemalgaim O=pants@ 230
0
0
0
0
Appliancsbti
0
0
Subtotal 0ir1es6to 13)
2558
2394
576
207
Lessextemalload
0
0
0
0
Lestranger
0
0
0
0
14
Redistribuffon
Subt#d
0
2558
0
2394
0
576
0
207
15
Dudloads
25%
34%
629
811
25%
34%
142
70
Total room load
Air required (dm)
3187
152
3205
149
718
34
278
13
_Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed
c wr4�hts4a'Ie` �rA .021 07 2021-Jo-121321:40
-.\WrigFoftHACWMWEBUI�JNG-TECOTiAGE.nLp CaIc=M1B FwtDoofacesSW Page 2
-�mightsoft, Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317ST. LUCIE LANE, FORTPIERCE, FL34946 Phom:772.466-6799 Email: QUICKCALCS@AOL.COM
1
Room name
CLOSET
GREAT ROOM
2
5posed Hall
0 ft
32.0 ft
3
Room height
8.1 ft heaUmol
8.1 ft heaV=l
4
Room dimensions
9.0 x 7.0 ft
1.0 x 452.0 R
5
Room area
63.0 T
452.0 IF
Ty
Construction
U-value
Or
HTM
Area (
Load
Area (fe)
Load
number
(aWhw- °�
(Bfuh/ft=)
or perimeter (R)
(13Wh)
or perimeter
r (ft)
(BWh)
Heat
Cool
Grass
WP/S
Heat
Cool
Gros
WP5
Heat
Cool
6
VL-G
13A-4oa
0.143
n
4.00
2.19
0
0
0
0
178
160
640
350
2glaarg,droutr,
1.040
n
29.12
21.68
0
0
0
0
18
0
537
400
13A-4aas
0.143
a
4.00
2.19
0
0
0
0
0
0
0
0
2 glazing, droue,
1.040
a
29.12
39.42
0
0
0
0
0
0
0
0
11
1100
0390
a
1092
1034
0
0
0
0
0
0
0
0
VL1M-4ors
0.143
s
4.00
2.19
0
0
0
0
0
0
0
0
-(3
2glazing,droutr,
1.040
s
29.12
21.68
0
0
0
0
0
0
0
0
13AAo s
0.143
w
4A0
2.19
0
0
0
0
81
40
161
88
1Aclom
1270
w
35S6
34.77
0
0
0
0
41
41
1451
1419
1A-h1om
1270
w
3556
61.76
0
0
0
0
0
0
0
0
1A-h1om
1270
w
35M
63.40
0
0
0
0
0
0
0
0
C
16CJ0m1
0.032
-
0.90
128
63
63
56
81
452
452
405
579
F
22A4p1
0.989
-
27.69
0.00
63
0
0
0
452
32
am
0
6
c)AED excurson
-1
2069
Envelopelossgain
56
80
4080
4903
12
a) Infiltratian
0
0
539
148
b) Room ventilation
0
0
0
0
13
Inbamalgains O¢vparrs@ 230
0
0
2
460
Appliancs(ather
0
0
Subtotal(iines6to 13)
56
80
4619
5511
Lesexdemalload
0
0
0
0
Lestransfer
0
0
0
0
Redistnbution
0
0
0
0
141
Subtotal
56
80
4619
5511
151
Dudloads
25%
34%
14
27
25%
349/6
1135
1868
Total room load
70
107
5754
7179
Airrequired (dm)
3
5
274
1
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
wr�9htsof!^ Rigtd919.021RSU08101 2021-JaM21321AOc_.\WdgF6oftUACWVNEBUIDLING-THECOTAGE.rup Glc=rUB FmrtWorao:sSW Page al
-� wrightsoft° Right-JO Worksheet Jab:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: T2466-6799 Emall:QUICKCALCS@AOL.COM
1
Room name
MASTER BATH
POWDER
2
Exposedwall
5D ft
0 ft
3
Roan height
8.1 ft healmol
8.1 It heatbool
4
Room dimensons
Mo x 6.0 ft
5.0 x 5.0 ft
5
Room area
50.0 1F
25.0 IF
Ty
Construction
U-value
Or
HTM
Area (ff)
Load
Area
Load
number
(BG1h4F-°Fj
(BWhfll�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gros
N/P/S
Heat
Cool
Gros
NIPS
Heat
Cool
6
vd
13A-0as
0.143
n
4.00
2.19
0
0 0
0
0
0 0
0
�G
2glaarg,droutr,
1.040
n
29.12
21.68
0
0
0
0
0
0 0
0
13A-4ors
0.143
a
4.00
2.19
0
0
0
0
0
0
0
0
2glaang,croulr,
1.040
a
29.12
39.42
0
0
0
0
0
0
0
0
11
D
11D0
0.390
a
1092
10.34
0
0
0
0
0
0
0
0
W
13A4c s
0.143
s
4.00
2.19
41
34
134
73
0
0
0
0
—G
2glaang,droutr,
1.040
s
29.12
21.68
7
7
202
150
0
0
0
0
13A-0ws
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
1Aciom
1270
w
3556
34.77
0
0
0
0
0
0
0
0
1A-h1om
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
IA-hlom
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
C
16C30ml
0.032
-
0.90
128
50
50
45
64
25
25
22
32
F
22A-tpI
0.989
-
27.69I
0.00
I
50
5
138
0
25
0
0
0
6
c)AED excursion
y
0
Envelope los/gain
520
284
221
32
12
a) Infiltration
84
23
0
0
b) Roomventlafion
0
0
0
0
13
Intemalgains: Occupants@ 230
0
0
0
0
Appliancesrolher I
0
0
Subtotal(linestito13)
6134
307
1
22
32
Leseremalload
0
0
0
0
Lesstransfer
0
0
0
0
Redishibufion I
0
01
0
0
14
Subtotal
604
307
22
32
15
Duct loads
25%
34%
148
104
25"/
34%
61
11
Total room load
752
411
28
42
Airrequired (cfm)
36
19
1
2
Calculabons approved bvACCAtO meet all requirements of Manual J 8th Ed
-rid-
mtr!o _ 2021 Jan121321:40
�^`A RigkSuteGUriversa1201919.021 RSW8101 Page 4
...\Wdgta=oft FNAC\WYNNEBUIDLING-THECOTTAGE.np CaIc=W8 Frort Coorlaws:SW
wrightsoft- Right-J@ Worksheet ,lob.
Entire House By.
QUICK CALCS, INC. By.
317ST. LUCIE LANE, FORTPIERCE, FL34946 Phore:772466-6799 Email:OUICKCALCS@AOLCOM
1
Room name
KITCHEN
LAUNDRY
2
Emo.ed wall
38.0 ft
0 ft
3
Room height
8.1 it heatmol
8.1 it heaV=l
4
Room dimensions
1.0 x 232,0 ft
4.0 x 10.0 ft
5
Room area
232.0 fF
40.0 iF
Ty
Construction
U-value
Or
HTM
Area ([F)
Load
Area (in
Load
number
I
(BWh&[ F)
(BWh/fl
or perimeter (ft)
(BWh)
or perimeter (ft)
(BWh)
Heat
I Cool
Gros
NIPS
Heat
Cool
Gros
NIPS
Heat
Cool
6
Yil
13A-4ocs
0.143
n
4.00
219
138
138
551
301
0
0
0
0
--G
2glaang,droutr,
1A40
n
29.12
21.68
0
0
0
0
0
0
0
0
13AAors
0.143
a
4.00
2.19
130
97
387
211
0
0
0
0
2giaang,droutr,
1.040
a
29.12
39.42
13
2
368
498
0
0
0
0
11
D
11DO
0.390
a
10.92
10,34
20
20
223
211
0
0
0
0
VN
13AA=
0.143
s
4A0
2.19
41
41
162
89
0
0
0
0
t-G
2glaang,droutr,
1A40
s
29.12
21.68
0
0
0
0
0
0
0
0
13A4o s
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
1A-dom
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
1A-htom
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
IA-htom
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
C
16C30ml
0.032
-
0.90
128
232
232
208
297
40
40
36
51
F
22A-ipl
0.989
-
27.69
0.00
232
38
1052
0
40
0
0
0
6
c)AED e=urson
-37
-1
Envelope losagain
2951
1570
36
51
12
a) Infiltralion
640
175
0
0
b) RoomvenAlaton
0
0
0
0
13
Internal gains: Ooolpans@ 230
0
0
0
0
Applianre,4olher
1000
0
Subbtal(lines6W13)
3591
2745
36
51
Lesezdemal load
0
0
0
0
Less transfer
0
0
0
0
Redishibuton
0
0
0
0
14
SubWml
3591
2745
36
51
15
Duct loads 1
25%
34%
883
931
25%
34%
9
17
Total mom load
4474
3676
68
Air required;Qm)
213
177
2
3
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
9&-r ld- ,a��
... RgkSuR919.021 RSU08101 2021-JarFl 21321:40
Wdg6HAQWNNEBUDLING-THECOTCAGE.ruo CIc=MJB FrortOooraresSW Page
wrightsoftRight-JM Worksheet Jab:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466£799 Email: QUICKCALCSa@AOL.COM
1
Room name
STORAGE
2
Eposedwall
8.0 it
3
Room height
8.1 It heaVmol
4
Rwm dimensions
4.0 x 6.0 it
5
Room area
24.0 1F
Ty
Construction
U-value
Or
HTM
Area (II')
Load
Area
Load
number
(BtuhHF°r7
(BWtdR
or perimeter (fi)
(BWh)
or perimeter
Heat
Cool
Gros
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Yr/
13A4=
0.143
n
4.00
2.19
32
32
130
71
�—f
2glazing. dr outr,
1.040
In
29.12
21.68
0
0
0 0
13A4or_s
0.143
a
4.00
2.19
32
32
130
71
2glaang,droutr,
1.040
a
29.12
39A2
0
0
0 0
11
11DO
0390
a
1092
10.34
0
0
0 0
t—G
13A4as
0.143
s
4.00
2.19
0
0
0 0
2glazing, droutr,
1.040
s
29.12
21.68
0 0
0
0
13A4os
0.143
w
4.00
2.19
0
0
0
0
1A-dom
1270
w
3556
34.77
0
0
0
0
1Xh1om
1270
w
35.56
61.76
0
0
0
0
1A-Mom
1270
w
35.56
63.40
0
0
0
0
C
161330ml
0.032
-
0.90
128
24
24
22
31
F
22A-tll
0.989
-
27.69
I
0.00
24
8
222
0
6
c)AED imurson
3
Envelopeloss/gain
502
170
12
a) Infiltration
135
37
b) Room venfilabon
0
0
13
Internal gains: Oovpants@ 230
0
0
Appliances/other
0
Subtotal (lines 6 to 13)
637
207
Les exam.] load
0
0
Lestrarder
0
0
Redistribution
0
0
141
Subtotal
637
207
15
Ductloads
25%
29%
157
60
Total room load
794
266
Air required(Um)
38
12
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
�F► wrtglaLsoT!'
AC0KRigtiSuteC�llrnersa1201979.021 RSU06107 Page6
.lW2021-Jarv121321:40
..righboltHVAQWYNNEBUIDLING-THECO17AGE.rnp Calc=M18 Fmi-tCoorfaces:SW
Duct System Summary Job:
wrightsoft® y ry Date:
Entire House BY
QUICK CALCS, INC.
317ST. LUCIE LANE, FORTPIERCE, FL34946 P1nfe: 77246&6799 Email: QUICKCALCS@AOL.COM
I Project Information
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.50
in H2O
0.28
in H2O
022
in H2O
0.110/0.110
in H2O
0.080
in/100ft
967
dim
126
Supply Branch Detail Table
Cooling
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/100ft
967
cbn
Name
Design
(Btuh)
Htg
(CFm)
Clg
(dm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (it)
Ftg.Egv
Ln (ft)
Trunk
CLOSET
C 107
3
5
0.080
4.0
Ox0
VIFx
24.6
90.0
st1
DEN
h 3187
152
149
0.080
7.0
OxO
VIFx
33.5
90.0
st1
GREAT ROOM
c 3689
137
172
0.080
8.0
Ox0
VIFx
14.6
70.0
GREATROOM-A
c 3689
137
172
0.080
8.0
Ox0
VIFx
16.1
70.0
KITCHEN
h 4474
213
171
0.080
7.0
OxO
VIFx
4.5
70.0
LAUNDRY
c 68
2
3
0.080
4.0
Ox0
VIFx
5.4
70.0
MASTERBAiFi
h 752
36
19
0.080
4.0
OxO
VIFx
32.9
90.0
SO
MASTERBEDROOM
c 2671
107
124
0.080
7.0
OxO
VIFx
27.9
90.0
st1
MASTER BEDROOM -A
C 2671
107
124
0.080
7.0
OxO
VIFx
35.9
90.0
st1
POWDER
C 42
1
2
0.080
4.0
Ox0
VIFx
292
90.0
st1
SINKAREA
h 718
34
13
0.080
4.0
Ox0
VIFx
30.9
90.0
st1
STORAGE
h 794
38
12
0.080
4.0
Ox0
VIFx
11.2
70.0
Name
Trunk
Type
Htg
(dm)
Clg
(cim)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Dud
Material
Trunk
st1
PeakAVF
441
437
0,08
5561
12.0
0 x 0
VinIFIX
Wright soft® 2021-Jarv121321:41
A •W+-� w��.-, Rgk-Suk&Uriwrs1201919.021RSU08101 Paget
...1Wngt6ofl HJAaWYNNEBUIDLING-THECOTTAGE. Calc=MJ6 %tDoor%.:SW
Name
Grille
Size (in)
Htg
(Cfm)
Clg
(Cfm)
TEL
(ft)
Design
FR
Veloc
(ipm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Dud
Mat
Trunk
rbl
Ox0
967
967
0
0
0
0
Ox 0
MFx
wrightsoft" 2021Jar 121321:41
•..+�• �..m+�-o..� RigKSute@Unversa120t919.027 RSU08101 Page ...Wnghbo HJADWYNNEBUIDLING-THECOTTAGE.np Calc=MJB Frort Doorfaces:SW