Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutBUILDING PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
8/3/21 Permit Number:
Date:
2Y aUR
W-�
P1. ` ° Building-RermitApplication--.-
Planning and Development Services X
Commercial Residential
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772)462.1578
PERMIT APPLICATION FOR:
Address: 10701 s ocean dr 921
PropertyTax ID tt: 4511-510-0121-000-1 Lot No.
Block No,
Site Plan Name:
Name: Jason anzulis
Project
Tag
18000 btu, 18.90 seer, no kw
LIKE FOR LIKE A/C CHANGE OUT
12000 btu, 18.90 seer, no kw
7000 btu, 18.90 seer, no kw
New Electrical Meter Second Electrical Meter
Jvaggsg
Additional work to be performed undertltlspermlt—checkallthat apply:
XMechanical _Gas Tank _Gas Piping _Shutters _Windows/Doors _Pond
_Electric Plumbing —Sprinklers ^Generator _Roof Pitch
Sq. Ft, of First Floor:
Total Sq. Ft of Construction: _
7013,00 Utilities: Sewer Septic Building Height:
$
Cost of Construction: — —•
COJUTRTOR
U� IS E ESIIIEF y y
Christopher Langel
Name Jason anzulis _ Name: IIIII
Sea Coast A/C and Sheet Metal Inc.
Address: 10701 s ocean dr 921 company:
State-fl Address; 3108 Industrial 31 st Street
city: jensen beach
34947 city: Ft Pierce State: FL
Zip Code: Fax:
443-739-6930 Zip code: 34946 Fax: 772-448-4416
Phone IS _
Phone No 772-466-2400
E-Mail:
Fill in fee simple Title Holder on next page { if different E-Mail Info(seacOaatalr com
from the owner listed above) State or County License CMC035421
If value of construction is 2500 or more, a RECORDED Notice of Commencement is required.
if value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required.
SUP',LMNTAJ CD1S7RlICTTQt� (IC1y Lf�U1/ fL�Q{ZMA�TlDN10,
DESIGNER/ENGINEER: _Not Applicable
N .. .._ E
MORTGAGE COMPANY: Not Applicable
Name:
Name:_
Address:
Address:
City:
State:_.__
State:
City:
Phone_--.._——.
_
_—_..-_
_Zjp_._._Phone: -------
FEE SIMPLE TITLE HOLDER:
Not Applicable
BONDING COMPANY:
Not Applicable
Name:_
Name:
Address:
Address:
City:
_
City:
Zip: Phone:
Zip: Phone:
u ea
OWNER) CONTRACTOR AFFIDVIT: Application Is hereby made to onram a perm¢ to no uie wu,n a1lu �jj�L0,Ju,jU1[ aJ C1�u,........,
I certify that no work or installation has commenced prior to the Issuance of a permit.
St. Lucie Countyfl makes noyrepresentation that is granting a permit will authorize the permit holder to build the subject structure
structure. Please consult w thpyolur Home OwOwners
ers A sAssociation
ciat on land review bylaws
deed for any restrits ctions awhichtmay aprohibit such
-.-in-consideration ofthe -granting-of this requested. permit, Ldo hereby agree that .l_will, iri all spect
_res, perform , the work,...
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for
improvements to your property. A Notice of Commencement must be recorded in the public records
o f St.
Lucie County and posted on the jobsite before the first Inspection. If you intend to obtain financing,
ult
with lender or an attorney before commencin work or rec'orrdin our No ice of C�jommencement.
as Agent
STATE OF FLO,�IpPt ��
COUNTY OF "�iT" 6
Sworn
to (or affirmed) and subscribed before me of
Physical Presence or� Online Notarization
this 3 day of 41JIL[ . 2021 by
Name of person m skiing statement.
Personally Known 3._ OR Produced idendfication
Type of Identification
-,(signature of Notary
Commission No,
REVIEWS FI
Cc
DATE
RECEIVED
DATE
COMPLETED
ev.
JUBTINAL,
STATE OF FLOfjl�.4
S onto (or affirmed) and subscribed before me of
Physical Presence or_Oniine Notarization
this 3 day of IUIY , 2021! by
k AA ns het'
Name of person making statement.
Personally Known X OR Produced Identification,_
Type of Identification
of Notary Public- Statelof r-lorida
VEGETATION
REVIEW
Eligible for Federal Tax Credit.
AI IRI Certified Reference Number : 8103542 Date ; 08-02-2021 Model Status :Production Stopped
AI-IRI Type : HMSV-A-CB (Multi -Split Beat Pump)
Outdoor Unit Brand Name: DAIKIN
Outdoor Unit Model Number : 2MXS18NMVJU
Indoor *type : Non -Ducted Indoor Units
Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary
Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing:
Cooling Capacity (95F) : 18000
EER (95F) : 12.50
SEER : 18.90
High Heat (47F) : 18900
1_ow Heat (17P): 12000
HSPF:10.70
Sold in? : USA, Canada
t"Active" Model Status are those That an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being
iarkefed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Cedifcation Program Participant is no longer producing 6U1' is still
Ran Iling or offering for sale.
hn s that are accom anted b WAS indicate an involunta a -rate. The new ubiished ratio is shown alon with the r e. WAS ratio .
DISCLAIMER
AHRI does not endorse the products) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the products), or the
authorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the
directory at www.abrivirectIny.org.
TERMS AND CONDITIONS
This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and
confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated;
entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's individual,
personal and confidential reference. AIR-CONDITIONING, HEAn NG,
CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE
The information for the model cited on this certificate can be verified at www.ahridirectory.prg, click on "Verify Certificate" link „e mak,, lilt: h„uor
and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, _
which is listed above, and the Certificate No., which is listed at bottom right. - -__-- --- --- --
©2021 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: sz7za0asogszszsls
For: JasonAnzulis
10701 S Ocean Drive Lot # 921, Jensen Beach, FL 34957
Phone: 973 224-3951
Notes: 10701 S Ocean Drive Lot 921
esian inforinatton .
Weather; Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 93 OF
Inside db 70 OF Inside db 75 OF
Design TO 28 OF Design TD 18 OF
Daily range M
Relative humidity 50
Moisture difference 57 grilb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 9129 Btuh Structure 9498 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 28 Btuh Blower 1707 Btuh
Piping 0 Btuh
Equipment load 9157 Btuh Use manufacturers data n
Rate/swingg multipplier 0.98
Infiltration Equipmentsensibleload 10981 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 4431 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg cooling (none)
Area (ft') 446 446 Equipment latent load 4431 Btuh
Volume (fta) 3566 3566
Airchangges/hour 0.61 0.32 Equipment Total Load (Sen+Lat) 15411 Btuh
Equiv. AVF (cfm) 36 19 Req. total capacity at 0.70 SHR 1.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make DAIKIN Make DAIKIN
Trade DAIKIN Trade DAIKIN
Model 2MXS18NMVJU Cond 2MXS18NMVJU
AHRI ref 8103542 Coil FTXS12LVJU, CTXS07LVJU
AHRI ref 8103542
Efficiency 10.7 HSPF Efficiency 12.5 EER518.9 SEER
Heating input Sensible cooling 12600 Btuh
Heating output 18900 Btuh@47'F Latentcooling 5400 Btuh
Temperature rise 40 OF Total cooling 18000 Btuh
Actual air flow 432 cfm Actual air flow 432 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0,045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0,72
Capacity balance point = 0 OF
eoldr(allc values have been manually overridden
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
"� wrightsoft.. 7.021-Aug-0306:/i /:28
�-;� ,,..............:........ ...... Right-SuileW llnvefsa1201919.0.i3 RSU2664A Pagei
AC:CA C:NserslaversaVlesklopksl. Vincent depad.riq CaIc=MJe FroA Door faces: E
For: JasonAnzulis
10701 S Ocean Drive Lot# 921, Jensen Beach, FL 34957
Phone: 973 224-3951
Notes: 10701 S Ocean Drive Lot 921
�&Ok � ������ . Ides n.lriformat�on `�, � �... _� -,�, NNE�
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 93 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 18 OF
Daily range M
Relative humidity 50
Moisture difference 57 g0b
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 6864 Btuh Structure 6759 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 20 Btuh Blower 1707 Btuh
Piping 0 Bluth
Equipment load 6884 Btuh Use manufacturer's data n
Rate/swingg multipplier 0.98
Infiltration Equipmentsensibleload 8296 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 3221 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Cooling (none)
Area (It') 334 334 Equipment latent load 3221 Btuh
Volume (it') 2670 2670
Airchanges/hour 0.58 0.30 Equipment Total Load (Sen+Lat) 11517 Btuh
Equiv. AVF (cfm) 26 14 Req. total capacity at 0,70 SHR 1.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make DAIKIN Make DAIKIN
Trade DAIKIN Trade DAIKIN
Model 2MXS18NMVJU Cond 2MXS18NMVJU
AHRI ref 8103542 Coil FTX12SLVJU
AHRI ref 8103542
Efficiency 10.7 HSPF Efficiency 12.5 EER, 18.9 SEER
Heating input Sensible cooling 12600 Btuh
Heating output 18900 Btuh @470F Latentcooling 5400 Btuh
Temperature rise 56 OF Total cooling 18000 Btuh
Actual air flow 308 cfm Actual air flow 308 cfm
Air flow factor 0,045 cfm/Btuh Airflowfactor 0,045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0,72
Capacity balance point = 0 OF
Backup:
Input=21<W, Output= 6884 Btuh, 100AFUE
6old(rtalic values have been manually ovenitldon
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
wrig"tsoft" 2021-Arg-0306:5'/:01
�rlkll Rtgtt-SJIe®Universal 201919.0.13 RSU28644 F�age1
ACCA C:UlsorslaversaV7osktop\sl. Vlr[erR tlepaJ.rrq CaIc=MJB Front Door faxs: E
For: JasonAnzulis
10701 S Ocean Drive Lot # 921, Jensen Beach, FL 34957
Phone: 973 224-3951
Notes: 10701 S Ocean Drive Lot 921
W�JIW am
�De`si n lriformat�on -K ...f w
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 93 OF
Inside db 70 OF Inside db 75 OF
Design TD 28 OF Design TD 18 OF
Daily range M
Relative humidity 50 %
Moisture difference 57 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 2265 Btuh Structure 2739 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 8 Btuh Blower 1707 Btuh
Piping 0 Btuh
Equipment load 2273 Btuh Use manufacture's data n
Rate/swingg multipplier 0.98
Infiltration Equipmentsensibleload 4356 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1710 Btuh
Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area (ft') 112 112 Equipment latent load 1710 Btuh
Volume(fh) 896 896
Airchangqes/hour 0.70 0,37 Equipment Total Load (Sen+Lat) 6066 Btuh
Equiv.AVF (cfm) 10 5 Req. total capacity at 0.70 SHR 0.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make DAIKIN Make DAIKIN
Trade DAIKIN Trade DAIKIN
Model 2MXS18NMVJU Cond 2MXS18NMVJU
AHRI ref 8103542 Coil CTXS07LVJU
AHRI ref 8103542
Efficiency 10.7 HSPF Efficiency 12.5 EER, 18.9 SEER
Heating input Sensible cooling 12600 Btuh
Heating output 18900 Btuh@47'F Latent cooling 5400 Btuh
Temperature rise 138 OF Total cooling 18000 Btuh
Actual air flow 125 cfm Actual air flow 125 cfm
Air flow factor 0.055 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.72
Capacity balance point = 0 OF
eoldrifalic values have been manually ovemdden
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
-F'(.r' wri9htsoft'" )0)t-!\ug-030%O1:Sh
vt, ...,..,-,,,_,................ Ri9tA'Sule®Unvefsa120t919.0.t3 RSU26644 Pa9c1
ACCA CWsers�aversaV]esMoptsl. Vincent depaul.rup CaIc=MJB Frori DooF tams: E
For: JasonAnzulis
10701 S Ocean Drive Lot # 921, Jensen Beach, FL 34957
Phone: 973 224-3951
Design Conditions
Outdoor design DB:
OOF
Sensible gain:
11205
Btuh Entering coi I DB: 78.70F
Outdoor d-
: 0 017
Latent gain:
4431
Btuh Entering coil VVB: 63.80F
Indoor design DB:
75,OOF
Total gain:
15635
Btuh
.o
0%
Estimated airflow:
432
cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype:
SpIitASHP
Manufacturer:
DAIKIN
Model: 2MXS18NMVJU+FTXSI2LVJU, CTXS07LVJU
Actual airflow:
432
cfm
Sensible capacity:
12600
Btuh
112%of load
Latent capacity:
5400
Btuh
122% of load
Total capacity:
18000
Btuh
115%of load SHR: 70 %
Outdoor design DB: 42.0°F Heat loss: 9157 Btuh
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type:
SpIitASHP
Manufacturer:
DAIKIN
Actual airflow:
432 cm
Output capacity:
18900 Btuh
Supplemental heat
required:
Entering coil DB: 70.0°F
Model: 2MXS18NMVJU+FTXS12LVJU, CTXS07LVJU
206% of load
0 Btuh
Meets all requirements ofACCA Manual S.
Capacity balance: 0 °F
Economic balance: 0 °F