Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEM
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL16709-R7 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer CertainTeed, LLC (Roofing) Address/Phone/Email 20 Moores Road Malvern, PA 19355 (610) 893-5400 mark.d.harner@saint-gobain.com Authorized Signature Mark Harner mark.d.harner@saint-gobain.com Technical Representative Mark D. Harner Address/Phone/Email 18 Moores Road Malvern, PA 19355 (610) 651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 11/13/2022 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL16709_R7_COI_2020_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2015 ASTM D2178 2015 ASTM D4601 2012 ASTM D6162 2015 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 ASTM G155 2013 FM 4470 2016 FM 4474 2011 RAS 117 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/11/2020 Date Validated 09/18/2020 Date Pending FBC Approval 10/01/2020 Date Approved 12/15/2020 Date Revised 03/18/2021 Summary of Products FL #Model, Number or Name Description 16709.1 Flintlastic Modified Bitumen Roof Systems SBS and APP modified bitumen roof systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-97.5 Other: 1.) The design pressure in this application pertains to the maximum design pressure for one particular assembly for use in Zone 1 PRIME (field area) of the roof. Refer to ER Appendix for all systems and attachment limitations. 2.) Refer to ER Section 5 for Limits of Use. Installation Instructions FL16709_R7_II_2020_09_03_FINAL_A1_ER_CERATINTEED_MODBIT_FL16709- R7.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL16709_R7_AE_2020_09_03_FINAL_ER_CERTAINTEED_MODBIT_FL16709- R7.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT CertainTeed, LLC 20 Moores Road Malvern, PA 19355 (610) 893-5400 Evaluation Report C40710.12.13-R7 FL16709-R7 Date of Issuance: 12/02/2013 Revision 7: 09/03/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product descr ibed herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Flintlastic® Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manuf acturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus 25-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/03/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval proc ess of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless r etained specifically for that purpose. © 2019 NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R7 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL16709-R7 Flintlastic® Modified Bitumen Roof Systems Revision 7: 09/03/2020 Page 2 of 4 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category:Roofing Sub-Category:Modified Bitumen Roof Systems Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by CertainTeed, LLC, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.6 Accelerated weathering ASTM G155 2013 1504.7 Impact resistance FM 4470 2016 1507.1.1 Material standard ASTM D1970 2015 1507.10.2 Material standard ASTM D2178 2015 1507.10.2 Material standard ASTM D4601 2012 1507.11.2 Material standard ASTM D6162 2015 1507.11.2 Material standard ASTM D6163 2015 1507.11.2 Material standard ASTM D6164 2011 1507.11.2 Material standard ASTM D6222 2011 1507.11.2 Material standard ASTM D6509 2015 1519.11 Attachment Requirements RAS 117 1995 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties C7290.01.08 01/16/2008 ERD (TST6049) Physical Properties C10080.09.08 09/04/2008 ERD (TST6049) FM 4470/4474 C8370.08.08-R1 10/05/2009 ERD (TST6049) FM 4470/4474 C30310.12.09 12/17/2009 ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/2010 ERD (TST6049) FM 4470/4474 3519.12.03-R1 04/15/2011 ERD (TST6049) Physical Properties C42110.08.12 08/13/2012 ERD (TST6049) FM 4470/4474 C46090.11.13-A 11/20/2013 ERD (TST6049) FM 4470 CTR-SC9920.01.16-R1 01/20/2016 FM (TST1867) FM 4470/4474 3048520 09/19/2013 MTI (TST2508) Physical properties DX08C4A 03/22/2004 MTI (TST2508) Physical properties DX20E3A 03/22/2004 MTI (TST2508) Physical properties DX20E3A-001 01/04/2006 MTI (TST2508) Physical properties AX31G8A 08/21/2008 MTI (TST2508) Physical properties AX31G8D 09/05/2008 MTI (TST2508) Physical properties AX31G8F 06/05/2009 MTI (TST2508) Physical properties AX21G8C 01/28/2011 NEMO (TST6049) FM 4474 4L-CTR-18-002.09.18-2 09/21/2018 PRI (TST5878) Physical Properties CTC-032-02-01 01/16/2008 PRI (TST5878) Physical Properties CTC-034-02-01 11/24/2008 PRI (TST5878) Physical Properties CTC-066-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-067-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-068-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-070-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-071-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-093-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-116-02-01 04/03/2012 PRI (TST5878) Physical Properties CTC-183-02-01 10/04/2013 NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R7 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL16709-R7 Flintlastic® Modified Bitumen Roof Systems Revision 7: 09/03/2020 Page 3 of 4 Entity Examination Reference Date PRI (TST5878) Physical Properties CTC-259-02-01 12/11/2015 UL, LLC. (QUA9625) Quality Assurance Service Confirmation 11/13/2019 4. PRODUCT DESCRIPTION: This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed, LLC published installation instructions and the Limitations / Conditions of Use herein. TABLE 1: ROLL-GOODS FOR FLINTLASTIC® MODIFIED BITUMEN ROOF SYSTEMS Type Product Material Standard Plant(s) Reference Type Grade Base Sheets Flintlastic® SA NailBase ASTM D4601 II N/A Little Rock, AR ASTM D4601 II N/A Little Rock, AR All Sheet ASTM D4601 II N/A Little Rock, AR Sheet ASTM D4601 II N/A Little Rock, AR Flintlastic® Base 20 ASTM D4601 II N/A Little Rock, AR Flintlastic® Poly SMS Base Sheet ASTM D4601 II N/A Little Rock, AR Yosemite® Venting Base Sheet ASTM D4897 II N/A Little Rock, AR Ply Sheets Flintglas® Ply 4 ASTM D2178 IV N/A Shreveport, LA Flintglas® Premium Ply 6 ASTM D2178 VI N/A Shreveport, LA Base/Ply Membranes (APP) Flintlastic® APP Base T ASTM D6509 N/A N/A Little Rock, AR Flintlastic® STA ASTM D6222 I S Little Rock, AR Flintlastic® STA Plus ASTM D6222 I S Little Rock, AR Cap Membranes (APP) Flintlastic® STA ASTM D6222 I S Little Rock, AR Flintlastic® STA Plus ASTM D6222 I S Little Rock, AR Flintlastic® GTA ASTM D6222 I G Little Rock, AR Flintlastic® GTA CoolStar® ASTM D6222 I G Little Rock, AR Flintlastic® GTA-FR ASTM D6222 I G Little Rock, AR Flintlastic® GTA-FR CoolStar® ASTM D6222 I G Little Rock, AR Base/Ply Membranes (SBS) Flintlastic® SA PlyBase ASTM D1970 N/A N/A Little Rock, AR Black Diamond® Base Sheet ASTM D1970 N/A N/A Shakopee, MN Flintlastic® SA Mid Ply ASTM D6163 I S Little Rock, AR Flintlastic® Ultra Glass SA ASTM D6163 I S Little Rock, AR Flintlastic® Base 20 ASTM D6163 I S Little Rock, AR Flintlastic® Base 20 T ASTM D6163 I S Little Rock, AR Flintlastic® Ultra Poly SMS Base Sheet ASTM D6164 I S Little Rock, AR Cap Membranes (SBS) Flintlastic® SA Cap FR ASTM D6163 I G Little Rock, AR Flintlastic® SA Cap FR CoolStar® ASTM D6163 I G Little Rock, AR Flintlastic® FR Cap 30 ASTM D6163 I G Little Rock, AR Flintlastic® FR Cap 30 CoolStar® ASTM D6163 I G Little Rock, AR Flintlastic® FR Cap 30 T ASTM D6163 I G Little Rock, AR Flintlastic® FR Cap 30 T CoolStar® ASTM D6163 I G Little Rock, AR Flintlastic® SA Cap ASTM D6164 I G Little Rock, AR Flintlastic® SA Cap CoolStar® ASTM D6164 I G Little Rock, AR Flintlastic® FR-P ASTM D6164 I G Little Rock, AR Flintlastic® FR-P CoolStar® ASTM D6164 I G Little Rock, AR Flintlastic® GMS ASTM D6164 I G Little Rock, AR Flintlastic® GMS CoolStar® ASTM D6164 I G Little Rock, AR Flintlastic® Premium FR-P ASTM D6164 II G Little Rock, AR Flintlastic® Premium FR-P CoolStar® ASTM D6164 II G Little Rock, AR NEMO|etc. NEMO ETC, LLC Evaluation Report C40710.12.13-R7 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL16709-R7 Flintlastic® Modified Bitumen Roof Systems Revision 7: 09/03/2020 Page 4 of 4 5.LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low-slope roofs. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. 5.7.1 loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.7.2 The maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. PRIME design pressure requirements. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6. INSTALLATION: Flintlastic® Modified Bitumen Roof Systems shall be installed in accordance with CertainTeed, LLC published installation instructions, subject to the Limitations / Conditions of Use herein. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL, LLC. QUA9625; (414) 248-6409, karen.buchmann@us.ul.com - THE 25-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 1 of 25 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 2A Roof Cladding Design Pressures, Allowable Stress Design, Pasd, Exposure B 3 2A Roof Cladding Design Pressures, Allowable Stress Design, Pasd, Exposure C 4 2A Roof Cladding Design Pressures, Allowable Stress Design, Pasd, Exposure D 5 3 Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-9 4 Wood New, Reroof (Tear-Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 10-13 5 Wood New, Reroof (Tear-Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-17 6 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 18-21 7 Wood New, Reroof (Tear-Off) E Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22-25 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2. Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.3. For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 4. The maximum design pressure for the selected base assembly shall meet or exceed the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. This is already addressed in the tables that follow PRIME design pressure requirements. 5. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 6. Refer to FBC 1511 for requirements and limitations regarding recover installations. For Recover Applications using System Type D, the insulation is optional. 7. Unless otherwise noted, refer to the following references for bonded applications. TABLE 1: MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-AA (Base and Ply sheets, Asphalt-Applied) Base Ply: Glasbase; All Weather/Empire Base, Flexiglas Base, Flintlastic Base 20 Hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4, Flintglas Premium Ply 6 SBS-AA (SBS, Asphalt-Applied) Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Hot asphalt at 20-40 lbs/square Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar SBS-TA (SBS, Torch-Applied) Base Ply: Flintlastic Ultra Poly SMS Base, Flintlastic Base 20 T Torch-Applied Ply: One or more Flintlastic Ultra Poly SMS Base, Flintlastic Base 20 T Cap Ply: Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 2 of 25 TABLE 1(CONTINUED):MEMBRANE /ADHESIVE COMBINATIONSREFERENCE LAYER MATERIAL APPLICATION APP-TA (APP, Torch-Applied) Base Ply: One or more Flintlastic APP Base T, Flintlastic STA, Flintlastic STA Plus Torch-Applied Cap Ply: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar SBS-SA (SBS, Self-Adhering) Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Self-Adhering Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar 8. esign Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. 9. The following summary is the basis for the attachment tables herein. Tables 2A through 2C assume the following design parameters as defined in ASCE 7-16. Projects outside these design parameters are not applicable for use within the confines of this Evaluation Report. PARAMETER REFERENCE SYMBOL VALUE Design wind speed (mph)* FBC 1609.3 Vult Various Exposure Category FBC 1609.4.3 N/A B, C or D Topographical factor Section 26.8.2 Kzt 1.0 Wind directionality factor Section 26.6 Kd 0.85 Ground elevation factor Table 26.9-1 Ke 1.0 Roof slope N/A < 7° *Selection of the appropriate design wind speed and exposure category is the responsibility of the user, subject to acceptance by the Authority Having Jurisdiction. NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 3 of 25 TABLE 2A: ROOF CLADDING DESIGN PRESSURES, ALLOWABLE STRESS DESIGN, PASD (PSF) EXPOSURE CATEGORY B Exposure Category Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed - Vult (mph) FBC Figures 1609.3(1) through 1609.3(4) 110 120 130 140 150 160 180 200 B Open h < 15 1 PRIME -8 -10 -11 -13 -15 -17 -22 -27 1 -15 -18 -22 -25 -29 -33 -41 -51 2 -21 -25 -29 -34 -39 -44 -56 -69 3 -29 -35 -41 -47 -54 -61 -78 -96 15 < h < 20 1 PRIME -9 -11 -12 -14 -16 -19 -24 -29 1 -17 -20 -23 -27 -31 -35 -45 -55 2 -23 -27 -32 -37 -42 -48 -61 -75 3 -31 -37 -44 -51 -59 -67 -84 -104 20 < h < 30 1 PRIME -10 -12 -14 -16 -19 -21 -27 -33 1 -19 -22 -26 -30 -35 -40 -50 -62 2 -25 -30 -36 -41 -47 -54 -68 -84 3 -35 -42 -49 -57 -66 -75 -95 -117 30 < h < 40 1 PRIME -11 -13 -15 -18 -20 -23 -29 -36 1 -20 -24 -29 -33 -38 -43 -55 -68 2 -28 -33 -39 -45 -52 -59 -74 -92 3 -39 -46 -54 -62 -72 -82 -103 -128 Enclosed h < 15 1 PRIME -10 -12 -14 -16 -18 -21 -26 -32 1 -17 -20 -24 -28 -32 -36 -46 -56 2 -22 -27 -31 -36 -42 -48 -60 -74 3 -31 -36 -43 -50 -57 -65 -82 -101 15 < h < 20 1 PRIME -11 -13 -15 -17 -20 -22 -28 -35 1 -19 -22 -26 -30 -34 -39 -50 -61 2 -24 -29 -34 -40 -45 -52 -65 -81 3 -33 -40 -46 -54 -62 -70 -89 -110 20 < h < 30 1 PRIME -12 -14 -17 -19 -22 -25 -32 -39 1 -21 -25 -29 -34 -39 -44 -56 -69 2 -27 -33 -38 -44 -51 -58 -73 -91 3 -37 -44 -52 -61 -70 -79 -100 -124 30 < h < 40 1 PRIME -13 -15 -18 -21 -24 -28 -35 -43 1 -23 -27 -32 -37 -42 -48 -61 -75 2 -30 -36 -42 -48 -56 -63 -80 -99 3 -41 -48 -57 -66 -76 -86 -109 -135 NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 4 of 25 TABLE 2B: ROOF CLADDING DESIGN PRESSURES, ALLOWABLE STRESS DESIGN, PASD (PSF) EXPOSURE CATEGORY C Exposure Category Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed - Vult (mph) FBC Figures 1609.3(1) through 1609.3(4) 110 120 130 140 150 160 180 200 C Open h < 15 1 PRIME -12 -14 -17 -20 -22 -25 -32 -40 1 -23 -27 -32 -37 -42 -48 -61 -75 2 -31 -37 -43 -50 -57 -65 -82 -102 3 -43 -51 -60 -69 -80 -91 -115 -142 15 < h < 20 1 PRIME -13 -15 -18 -21 -24 -27 -34 -42 1 -24 -29 -34 -39 -45 -51 -65 -80 2 -33 -39 -46 -53 -61 -69 -88 -108 3 -46 -54 -64 -74 -85 -97 -122 -151 20 < h < 30 1 PRIME -14 -17 -19 -23 -26 -29 -37 -46 1 -26 -31 -37 -43 -49 -56 -70 -87 2 -36 -42 -50 -58 -66 -75 -95 -118 3 -50 -59 -69 -80 -92 -105 -133 -164 30 < h < 40 1 PRIME -15 -18 -21 -24 -28 -31 -40 -49 1 -28 -33 -39 -45 -52 -59 -75 -93 2 -38 -45 -53 -61 -70 -80 -101 -125 3 -53 -63 -74 -85 -98 -112 -141 -174 Enclosed h < 15 1 PRIME -14 -17 -20 -23 -27 -31 -39 -48 1 -25 -30 -35 -41 -47 -53 -67 -83 2 -33 -39 -46 -54 -62 -70 -89 -110 3 -45 -54 -63 -73 -84 -96 -121 -150 15 < h < 20 1 PRIME -15 -18 -22 -25 -29 -33 -41 -51 1 -27 -32 -37 -43 -50 -57 -72 -89 2 -35 -42 -49 -57 -66 -75 -95 -117 3 -48 -57 -67 -78 -90 -102 -129 -159 20 < h < 30 1 PRIME -17 -20 -23 -27 -31 -35 -45 -55 1 -29 -35 -41 -47 -54 -62 -78 -96 2 -38 -46 -54 -62 -71 -81 -103 -127 3 -52 -62 -73 -85 -97 -111 -140 -173 30 < h < 40 1 PRIME -18 -21 -25 -29 -33 -38 -48 -59 1 -31 -37 -43 -50 -58 -66 -83 -102 2 -41 -49 -57 -66 -76 -86 -109 -135 3 -56 -66 -78 -90 -104 -118 -149 -184 NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 5 of 25 TABLE 2C: ROOF CLADDING DESIGN PRESSURES, ALLOWABLE STRESS DESIGN, PASD (PSF) EXPOSURE CATEGORY D Exposure Category Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed - Vult (mph) FBC Figures 1609.3(1) through 1609.3(4) 110 120 130 140 150 160 180 200 D Open h < 15 1 PRIME -15 -17 -20 -24 -27 -31 -39 -48 1 -28 -33 -39 -45 -51 -58 -74 -91 2 -37 -44 -52 -61 -70 -79 -100 -124 3 -52 -62 -73 -84 -97 -110 -139 -172 15 < h < 20 1 PRIME -15 -18 -22 -25 -29 -33 -41 -51 1 -29 -35 -41 -47 -54 -62 -78 -96 2 -39 -47 -55 -64 -73 -83 -106 -130 3 -55 -65 -77 -89 -102 -116 -147 -181 20 < h < 30 1 PRIME -17 -20 -23 -27 -31 -35 -44 -55 1 -31 -37 -44 -51 -58 -66 -84 -103 2 -42 -50 -59 -68 -79 -89 -113 -140 3 -59 -70 -82 -95 -109 -124 -157 -194 30 < h < 40 1 PRIME -17 -21 -24 -28 -32 -37 -46 -57 1 -33 -39 -46 -53 -61 -69 -88 -108 2 -44 -53 -62 -72 -82 -94 -119 -146 3 -62 -73 -86 -100 -114 -130 -165 -204 Enclosed h < 15 1 PRIME -18 -21 -25 -28 -33 -37 -47 -58 1 -31 -36 -43 -50 -57 -65 -82 -101 2 -40 -48 -56 -65 -75 -85 -108 -133 3 -55 -65 -77 -89 -102 -116 -147 -182 15 < h < 20 1 PRIME -19 -22 -26 -30 -34 -39 -50 -61 1 -32 -38 -45 -52 -60 -68 -86 -107 2 -43 -51 -59 -69 -79 -90 -114 -141 3 -58 -69 -81 -94 -108 -123 -155 -192 20 < h < 30 1 PRIME -20 -24 -28 -32 -37 -42 -53 -66 1 -35 -41 -48 -56 -64 -73 -92 -114 2 -46 -54 -64 -74 -85 -96 -122 -150 3 -62 -74 -87 -101 -115 -131 -166 -205 30 < h < 40 1 PRIME -21 -25 -29 -34 -39 -44 -56 -69 1 -36 -43 -51 -59 -67 -77 -97 -120 2 -48 -57 -67 -77 -89 -101 -128 -158 3 -65 -77 -91 -105 -121 -138 -174 -215 NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 6 of 25 TABLE 3: WOOD DECKS NEW CONSTRUCTION OR REROOF (TEAR-OFF)SYSTEM TYPE A: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER INDICATES THE SYSTEM CANNOT BE USED WITHIN THE PRESSURE ZONE. System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 7) MDP (psf) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap PlyW-1 Min. 19/32-inch plywood Glasbase, All Weather Empire, Flexiglas Base, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails Pattern #1: 8-inch o.c. at the 3-inch side laps and 8-inch o.c. at three (3) equally spaced center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY-3, H-Shield or Multi-Max FA3 Hot asphalt, full coverage Min. 0.25-inch DensDeck primed with ASTM D41 primer or DensDeck Prime Hot asphalt, full coverage BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 ANCHOR SHEET ATTACHMENT PATTERN REFERENCES: PATTERN NO: #1 (AS-LISTED) #2 #3 #4 #5 #6 #7MIN. LAP WIDTH (inch): 3 3 3 3 3 3 3 MAX. LAP FASTENER SPACING (inch o.c.): 8 7 6 7 6 6 6 MIN. # OF EQUALLY SPACED CENTER ROWS: 3 3 3 4 4 5 5 MAX. CENTER ROW FASTENER SPACING (inch o.c.): 8 7 6 7 6 6 6 ANCHOR SHEET ATTACHMENT, SYSTEM W-1: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult (mph) 110 120 130 140 150 160 180 200 B Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #7 N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #7 N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 7 of 25 ANCHOR SHEET ATTACHMENT, SYSTEM W-1: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 B Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 #5 #7 N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 N/A N/A C Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #6 N/A 3 #1 (AS-LISTED) #2 #3 #4 #5 #7 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 N/A 3 #1 (AS-LISTED) #2 #3 #5 #7 #7 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #7 N/A 3 #2 #3 #4 #5 #7 N/A N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 8 of 25 ANCHOR SHEET ATTACHMENT, SYSTEM W-1: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 C Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 N/A 3 #1 (AS-LISTED) #2 #3 #4 #5 #7 N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #7 N/A 3 #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) N/A 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #7 N/A 3 #1 (AS-LISTED) #3 #4 #5 #7 N/A N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) N/A 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 N/A N/A 3 #2 #3 #5 #7 #7 N/A N/A N/A D Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 #5 #7 N/A 3 #1 (AS-LISTED) #3 #4 #5 #7 N/A N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 N/A N/A 3 #2 #3 #5 #6 #7 N/A N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) N/A 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 N/A N/A 3 #2 #3 #5 #7 N/A N/A N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) N/A 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #6 N/A 2 #1 (AS-LISTED) #2 #3 #4 #5 #7 N/A N/A 3 #3 #4 #5 #7 N/A N/A N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 9 of 25 ANCHOR SHEET ATTACHMENT, SYSTEM W-1: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 D Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) N/A 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 N/A N/A 3 #2 #3 #5 #6 #7 N/A N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) N/A 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 N/A N/A 3 #2 #3 #5 #7 N/A N/A N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) N/A N/A 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 N/A N/A 2 #1 (AS-LISTED) #2 #3 #4 #5 #7 N/A N/A 3 #3 #4 #5 #7 N/A N/A N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) N/A N/A 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A N/A 2 #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A 3 #3 #5 #7 N/A N/A N/A N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 10 of 25 TABLE 4: WOOD DECKS NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER INDICATES THE SYSTEM CANNOT BE USED WITHIN THE PRESSURE ZONE. System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 7) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply W-2 Min. 19/32-inch plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISO H primed with FlintPrime or FlintPrime SA Flintfast 3 in. Insulation Plates with FlintFast #12 or #14 Pattern #1 1 per 2 ft2 SBS-SA (Optional) SBS-SA SBS-SA -45.0Note: Board and stress plates shall be primed with FlintPrime for all Zone 2 & 3 installations INSULATION ATTACHMENT PATTERN REFERENCES: (AS-LISTED ABOVE) PATTERN #1: 1 per 2 ft2 PATTERN #2: 1 per 1.45 ft2 PATTERN #3: 1 per 1.33 ft2 PATTERN #4: 1 per 1.14 ft2 PATTERN #5: 1 per 1 ft2 NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 11 of 25 INSULATION ATTACHMENT, SYSTEM W-2: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 B Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #5 #5 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 N/A20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #4 #5 N/A30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 3 #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A N/AEnclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #5 N/A15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 N/A N/A30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #5 N/A3 #1 (AS-LISTED) #2 #2 #4 #4 #5 N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 12 of 25 INSULATION ATTACHMENT, SYSTEM W-2: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 C Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #5 N/A3 #1 (AS-LISTED) #2 #2 #4 #5 #5 N/A N/A15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A3 #2 #2 #3 #4 #5 #5 N/A N/A20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #4 #5 N/A3 #2 #2 #4 #5 #5 N/A N/A N/A30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #2 #4 #5 2 #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A N/A3 #2 #3 #4 #5 N/A N/A N/A N/AEnclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A3 #2 #2 #3 #4 #5 #5 N/A N/A15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #4 #5 N/A3 #2 #2 #4 #5 #5 N/A N/A N/A20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #5 #5 2 #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A N/A3 #2 #3 #4 #5 #5 N/A N/A N/A30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 N/A2 #1 (AS-LISTED) #2 #2 #4 #4 #5 N/A N/A3 #2 #4 #5 #5 N/A N/A N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 13 of 25 INSULATION ATTACHMENT, SYSTEM W-2: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 D Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 N/A N/A3 #2 #3 #4 #5 #5 N/A N/A N/A15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #5 #5 2 #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A N/A3 #2 #4 #5 #5 N/A N/A N/A N/A20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 N/A2 #1 (AS-LISTED) #2 #2 #4 #5 #5 N/A N/A3 #2 #4 #5 #5 N/A N/A N/A N/A30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A2 #1 (AS-LISTED) #2 #3 #4 #5 #5 N/A N/A3 #3 #4 #5 N/A N/A N/A N/A N/AEnclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #5 N/A2 #1 (AS-LISTED) #2 #2 #4 #4 #5 N/A N/A3 #2 #4 #5 #5 N/A N/A N/A N/A15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 1 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #2 #4 #5 N/A2 #1 (AS-LISTED) #2 #2 #4 #5 #5 N/A N/A3 #2 #4 #5 #5 N/A N/A N/A N/A20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 1 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #3 #4 #5 N/A2 #2 #2 #3 #4 #5 #5 N/A N/A3 #3 #4 #5 N/A N/A N/A N/A N/A30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 1 #1 (AS-LISTED) #1 (AS-LISTED) #2 #2 #4 #5 #5 N/A2 #2 #2 #4 #5 #5 N/A N/A N/A3 #3 #5 #5 N/A N/A N/A N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 14 of 25 TABLE 5: WOOD DECKS NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D: INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER INDICATES THE SYSTEM CANNOT BE USED WITHIN THE PRESSURE ZONE. System No. Deck (Note 1) Insulation Layer(s) Base or Anchor Sheet Roof Cover (Note 7) MDP (psf)Type Attach Base Fasteners Attach Base Ply and/or Ply Cap Ply W-3 Min. 15/32-inch plywood Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase; Flexiglas; Flintlastic Base 20; Poly SMS Base; Ultra Poly SMS Base; Yosemite Flintfast 3 in. Insulation Plates with FlintFast #12 or #14 Pattern #1: 6-inch o.c. at the 4-inch side laps and 6-inch o.c. at three (3) equally spaced center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA-97.5 BASE SHEET ATTACHMENT PATTERN REFERENCES: PATTERN NO: #1 (AS-LISTED) #2 #3 #4 #5 MIN. LAP WIDTH (inch): 4 4 4 4 4 MAX. LAP FASTENER SPACING (inch o.c.): 6 7 6 7 6 MIN. # OF EQUALLY SPACED CENTER ROWS: 3 4 4 5 5 MAX. CENTER ROW FASTENER SPACING (inch o.c.): 6 7 6 7 6 BASE SHEET ATTACHMENT, SYSTEM W-3: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult (mph) 110 120 130 140 150 160 180 200 B Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 15 of 25 BASE SHEET ATTACHMENT, SYSTEM W-3: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 B Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 C Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 16 of 25 BASE SHEET ATTACHMENT, SYSTEM W-3: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 C Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A D Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 17 of 25 BASE SHEET ATTACHMENT, SYSTEM W-3: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 D Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 N/A 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 #5 N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 18 of 25 TABLE 6: WOOD DECKS NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER INDICATES THE SYSTEM CANNOT BE USED WITHIN THE PRESSURE ZONE. System No. Deck (Note 1) Base Sheet Roof Cover (Note 7) MDP (psf) Base Fasteners Attachment Base Ply Cap Ply W-4 Min. 19/32-inch plywood Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails Pattern #1: 8-inch o.c. at the 2-inch side laps and 8-inch o.c. at three (3) equally spaced center rows (Optional) SBS-SA SBS-SA -60.0BASE SHEET ATTACHMENT PATTERN REFERENCES: PATTERN NO: #1 (AS-LISTED) #2 #3 #4 #5 #6 MIN. LAP WIDTH (inch): 2 2 2 2 2 2 MAX. LAP FASTENER SPACING (inch o.c.): 8 7 6 6 4 4 MIN. # OF EQUALLY SPACED CENTER ROWS: 3 3 4 5 4 5 MAX. CENTER ROW FASTENER SPACING (inch o.c.): 8 7 6 6 4 4 BASE SHEET ATTACHMENT, SYSTEM W-4: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult (mph) 110 120 130 140 150 160 180 200 B Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 19 of 25 BASE SHEET ATTACHMENT, SYSTEM W-4: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 B Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #4 #6 N/A C Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 #5 #6 N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 #6 3 #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 #5 #5 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 3 #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 20 of 25 BASE SHEET ATTACHMENT, SYSTEM W-4: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 C Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #4 #5 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 N/A 3 #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #4 #6 N/A 3 #1 (AS-LISTED) #2 #4 #5 #5 #6 N/A N/A D Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 3 #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 N/A 3 #1 (AS-LISTED) #2 #4 #4 #5 #6 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #4 #6 N/A 3 #1 (AS-LISTED) #3 #4 #5 #6 #6 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A 3 #2 #3 #4 #5 #6 N/A N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 21 of 25 BASE SHEET ATTACHMENT, SYSTEM W-4: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 D Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 N/A 3 #1 (AS-LISTED) #2 #4 #4 #5 #6 N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 #4 #6 N/A 3 #1 (AS-LISTED) #3 #4 #5 #6 #6 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #6 N/A 3 #2 #3 #4 #5 #6 N/A N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #4 #5 N/A N/A 3 #2 #4 #5 #6 #6 N/A N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 22 of 25 TABLE 7: WOOD DECKS NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER INDICATES THE SYSTEM CANNOT BE USED WITHIN THE PRESSURE ZONE. System No. Deck (Note 1) Base Sheet Roof Cover (Note 7) MDP (psf) Base Fasteners Attachment Base Ply and/or Ply Cap W-5 Min. 19/32-inch plywood Glasbase; Flexiglas; Flintlastic Base 20; All Weather / Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails Pattern #1: 8-inch o.c. at the 4-inch side laps and 8-inch o.c. at three (3) equally spaced center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0BASE SHEET ATTACHMENT PATTERN REFERENCES: PATTERN NO: #1 (AS-LISTED) #2 #3 #4 #5 #6 #7MIN. LAP WIDTH (inch): 4 4 4 4 4 4 4 MAX. LAP FASTENER SPACING (inch o.c.): 8 7 6 6 6 4 4 MIN. # OF EQUALLY SPACED CENTER ROWS: 3 3 3 4 5 4 5 MAX. CENTER ROW FASTENER SPACING (inch o.c.): 8 7 6 6 6 4 4 BASE SHEET ATTACHMENT, SYSTEM W-5: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult (mph) 110 120 130 140 150 160 180 200 B Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #5 #6 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 23 of 25 BASE SHEET ATTACHMENT, SYSTEM W-5: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 B Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #6 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #6 #7 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #5 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 N/A C Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #6 3 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 #5 #7 N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #3 #4 #5 #6 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 #7 3 #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 24 of 25 BASE SHEET ATTACHMENT, SYSTEM W-5: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 C Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 3 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #6 N/A 3 #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #5 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 N/A 3 #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A D Open h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #3 #6 #7 3 #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 N/A 3 #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #5 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 N/A 3 #1 (AS-LISTED) #3 #4 #5 #7 #7 N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #4 #5 #7 N/A 3 #2 #3 #5 #6 #7 N/A N/A N/A NEMO|etc.NEMO ETC, LLC Evaluation Report C40710.12.13-R7 for FL16709-R7 Certificate of Authorization #324557TH EDITION (2020) FBC NON-HVHZ EVALUATIONRevision 7: 09/03/2020©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems; (610) 893-5400 Appendix 1, Page 25 of 25 BASE SHEET ATTACHMENT, SYSTEM W-5: Exposure Enclosure Roof Height (ft) Zone Ultimate Design Wind Speed Vult(mph)110 120 130 140 150 160 180 200 D Enclosed h < 15 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED)1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #4 #6 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 N/A 3 #1 (AS-LISTED) #2 #3 #5 #6 #7 N/A N/A 15 < h < 20 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 #3 #5 #7 N/A 3 #1 (AS-LISTED) #3 #4 #5 #7 #7 N/A N/A 20 < h < 30 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #5 #7 N/A 3 #2 #3 #5 #6 #7 N/A N/A N/A 30 < h < 40 1 PRIME #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #3 1 #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #7 2 #1 (AS-LISTED) #1 (AS-LISTED) #2 #3 #5 #6 N/A N/A 3 #2 #3 #5 #7 #7 N/A N/A N/A