HomeMy WebLinkAboutBASINGER-ENERGY CALCFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: BAYSINGER ADDITION
BuilderName:
Street: 8801 S. INDIAN IRVER DRIVE
Permit Office:
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner:
Jurisdiction:
DesignLocalion: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Addition
10. Wall Type_(400.0 sqft.)
Insulation Area
2. Single familyormultiple family Detached
a. Frame -Wood, Exterior
R=13.0 240.00 ft'b.
Concrete Block- Ext lnsul, Exterior
R=4.0 160.00ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms(Bedrms In Addition) 0(0)
d.N/A
R= ft'
11. Ceiling Types (184.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck(Unvented)
R=20.0 184.00 fl'
6. Conditioned floor area above grade(ft') 184
b. N/A
R= fl'
Conditioned flocrarea belowgrade(ff) 0
c. N/A
R= fl'
7. Windows(48.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft'
6 45
a. U-Factor: Sgl, U=0.65 48.00 ft'
SHGC: SHGC=0.25
b. U-Factor: N/A ft.
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
9.0 SEER:18.80
c. U-Factor: N/A ft.
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.250
a. Electric Heat Pump
9.0 HSPF:11.00
8. Skylights Area
c. U-Factor:(AVG) U=0.65 2.0 ft'
15. Hot water systems -
SHGC(AVG): SHGC=0.25
a. Electric Tankless
Cap:1 gallons
9. Floor Types (184.0 sqft.) Insulation Area
EF: 0.600
a. Slab -On -Grade Edge Insulation R=0.0 184.00 ft'
b. Conservation features
b. N/A R= ft.
None
c. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.261 Total Proposed Modified Loads: 7.22
PASS
Total Baseline Loads: 9.13
1 hereby certify that the plans and specifications covered by
Review of the plans and
111E S'r
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
F n..,
PREPARED Y.
Before construction is completed
R1,
DATE: 4-19-202
this building will be inspected for
compliance with Section 553.908
°
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Energy Code.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
4/19/2021 9:20 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
BAYSINGER ADDITION Bedrooms: 0
Address Type: Street Address
Building Type:
User
ConditionedArea: 184
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
#of Units:
1
Worst Case: No
PlatBook:
BuilderName:
RotaleAngle: 0
Street: 8801 S. INDIAN IRVER
Permit Office:
CrossVentilation: No
County: St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip: FT. PIERCE,
FamilyType:
Detached
FL,
New/Existing:
Addition
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design DailyTemp
V DesignLocation
TMY Site 97.5% 2.5%
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce
FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Entire House
184 1840
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
BATH
88 880 No 0
1 Yes Yes Yes
2
KITCHEN
96 960 No
1 Yes Yes Yes
FLOORS
#
FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value Tile Wood Carpet
1 Slab -On -Grade Edge
Insulation BATH 19ft 0
88 ft'
____ 0 1 0
2 Slab -On -Grade Edge Insulation KITCHEN 20ft 0
96 ft'
____ 0 1 0
ROOF
/
Roof Gable Roof
Red
Solar SA Emitt Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr
Absor. Tested Tested Insul. (deg)
1
Gableorshed
Metal 194 ft2 30 ft2 Unfinishe
N
0.6 No 0.7 No 20 18.43
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvenled 0
184 ft2
N N
4/19/2021 9:20 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
CeilingType
Space R-Value Ins Type
Area Framing Frac Truss Type
1
2
UnderAttic(Unvented)
UnderAttic(Unvented)
BATH 0 Blown
KITCHEN 0 Blown
88 ft' 0.1 Wood
96 ft2 0.1 Wood
WALLS
Adjacent
Space Cavity Width Height
Sheathing Framing Solar
Below
1 N
2 W
-3 N
4 E
Exterior Frame -Wood BATH 13 12 0 10 0
Exterior Concrete Block -Ext lnsul BATH 4 8 0 10 0
Exterior Frame -Wood KITCHEN 13 12 0 10 0
Exterior Concrete Block- Ext lnsul KITCHEN 4 8 0 10 0
120.0 f12 0 0.25 0.8
80.0 f12 0 0 0.8
120.0 f12 0 0.25 0.8
80.0 ft2 0 0 0.8
0
0
0
0
WINDOWS
Orientation shown istheentered, Proposed orientation.
/
V #
Wall
Omt ID Frame Panes
NFRC U-Factor SHGC Imp Area
Overhang
Depth Separation IntShade Screening
1
2
3
4
W 2 Metal Low-ESingle
N 3 Metal Low-ESingle
NE Skylt Metal Low-ESingle
NE Skylt Metal Low-ESingle
Yes 0.65 0.25 N 24.0 ft2
Yes 0.65 0.25 N 24.0 ft2
Yes 0.65 0.25 N 1.0 f12
Yes 0.65 0.25 N 1.0 f12
2 fl0 in 1 fl4 in None
2 ft 0 in 1 ft 4 in None
2fl0 in 1ft4 in None
2fl0 in 1ft4 in None
None
None
None
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA
ACH ACH 50
1 Wholehouse ProposedACH(50)
.000317 153.3 8.41 15.79
.0987 5
HEATING SYSTEM
#
1
System Type
Electric HeatPump/Supplemen
Subtype Speed Efficiency
Split Single HSPF:11
Capacity Block
9kBtu/hr 1
Duds
sys#1
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Duds
1
Central Unit/Supplementalfora
Split Single SEER: 18.8 9 kBtu/hr dm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubTpe
Location EF Cap Use
SetPnt Conservation
1
Electric Tankless
Exterior 0.6 1gal 60.9gal
120 deg None
4/19/2021 9:20 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Carl #
CompanyName
System Model
Collector Model# Area
Volume
FEF
None
None
ft'
DUCTS
/
---- Supply ----
---- Return ---
Air
CFM25
CFM25
HVAC#
v #
Location R-Value
Area
Location
Area
LeakageType
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic 6
45 ft'
Attic
5ft'
Defaulti-eakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programable[[T]]hermostat::[
C[[ei]]ling Fans:Coolin
Jan
Feb
]]N
[[ ]]
[X]
]
[X]
]
Dec
[[X]]
Heating [X] Jan
[X] Feb
[X] Mar
Jun
[ ] Jul
4X] Aug
[ ] Sep
L 1
[[X]]
Dec
Vent ing 11 Jan
11 Feb
IXl Mar
Apr
[
] May
lXl Jun
11 Jul
11 Aug
11 Sep
lxl
Oct
[X] Nov
[ ] Dec
ThermostatSchedule:
HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
10
11
12
Cooling(WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling(WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Healing(WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Healing(WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
FumitureFmction
Space
Default(8lbs/sq.ft.
0 fl'
0 ft
0.3
BATH
Default 8lbs/sq.ft.
fl'
ft
0.3
KITCHEN
4/19/2021 9:20 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4