Loading...
HomeMy WebLinkAboutBAYSINGER CABANA PRODUCTS 2021SWING DOOR - LARGE MISSILE IMPACT 38" MAX. SINGLE DOOR WIDTH 35 5/8" MAX. PANEL WIDTH 24 5/8" GLASS DLO 96 3/4" MAX. UNIT HEIGHT 8 1/2" NOTE: HINGE SPACINGS ARE 8-1/2" FROM ENDS AND 20" MAX. O.C. FOR 81" TO 97" UNIT HEIGHT. 95 1 /8" B X B MAX. PANEL HEIGHT 84 1 /8" GLASS DLO B SEE 6 NOTE 4 TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS ..... 1 SECTION VIEWS & GLAZING..............2 BOM......................................................3 EXTRUSIONS.......................................4 ANCHOR SCHEDULE & NOTES .......... 5 INSTALLATION DETAILS.....................6 M7iv, GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. 2. GLAZING DETAIL: (SEE SHEET 2) RW-la9.10 9q1=KelkiIa1411.1_\IlelP69F9IkiCelE:9i111&VITAI.[e11 4. LOCK OPTIONS: • UP TO 6'8" : MULTIPOINT(4PT) (HANDLE SET @ 34"). • ABOVE 6'8": MULTIPOINT(5PT) (HANDLE SET @ 34"). 5. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04. -POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE, AND GLASS TABLES ASTM E-1300-04. 6. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR INSTALLATION DETAIL. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 7. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. 8. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. VENTS ARE PROCESSED AND TIERODDED TOGETHER. 9. SERIES / MODEL DESIGNATION: SD-8700. 10 THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X = OPERABLE DOOR. 11. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS. 12. INTERIOR FLUSH BOLTS ON ACTIVE PANEL TO BE ENGAGED DURING SEVERE WEATHER. MAX. UNIT SIZE DESIGN PRESSURE RATING I IMPACT RATING 38" x 96-3/4" +/-90 PSF I LARGE MISSILE IMPACT aV{]YlY®✓✓ 0 / II WINDOW SYSTEMS 11 l��lunJ 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700 PVC SWING DOOR IMPACT cn U Z m O a � N Z w w O cr d a o — w pC a U o U) d w Z:) o aZ � ,���� P�10RE W T t No 58201 'F71 r � :9 STATE OF yry�� • �; 0 R 4;'0NA� � %_ 4/18/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS AIDE 1 09/20/12 CWS-817 A 'ALE: SHEET 1:20 1 OF 6 NOTICE OF PRODUCT CERTIFICATION �� CERTIFTL.,� ny ACegFO,T Company: Masonite International Corporation Certification No.: 1955 Powis Road Certification Date: West Chicago, IL 60185 Expiration Date: Revision Date: NI013717.06-R3 05/12/2017 05/31/2025 11/11/2020 Product: Fiberglass Opaque Inswing or Outswing Door w/ and w/o Non -Impact Rated Sidelites cF """" (w/Wood Frame unless noted) EDP Specification: TAS 202-94/ASTM E330-02/ASTM E1886-05/13a/ASTM E1996-09/14a Impact: Missile Level D Non -Impact Sidelites: Insulating Glass (Tempered) The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertification.com. NAMPs Certification Program is accredited by The American National Standards Institute (ANSI). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & Outswing Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0"X 8'0" +70/-70 0.0 psf Yes NCTL-210-3835-1/W-1972 Single s Anchor Detailnnurn DWG-MA-FLO210-17 X O/S Opaque 3'0" X 8'0" +70/-70 3.75 psfl Yes NCrL-210-3835-1/W 1843/W-1972 Single 6.0 psf ' 8.2.25 psfsf ' Anchor D .fl DWG-Mn FIA2 417 9.0 pSf 4 XX I/S Opaque 6'0"X 890" +50/-50 0psf Yes NCTL-210-3849-1/ATLNC 0306.01-17/0308.01-17/W-1972 Double Maximum Panel Size: 3'0" x 8'0" Anchor Details-DWG-MA-FLOl88-17 XX O/S Opaque 6'0"X 810" +50/-50 3.75 pst' Yes NCTL-210-3849-1/ATLNC 0306.01-17/0308.01-17/W-1843M-IW2 Double 6.0 psf' Maximum Panel Size: 3'0" x 8'0" 8.25 psf 'I Anchor Details-DWG-MA-FLO188-17 8.25 pSf 4 XO/OX I/S Opaque Door 6'0"X 8'0" +501-50 Opst Door -Yes NCIL-210a849-1/ATLNC0306.01-17/0308.01-17m-1972 le w/Sidelite Glazed Sidelite Sidelite-No MinPanel Siz:3'0"x 8'o/SiMite:3'0"x 8'0" Anch.,D.ils-DWG-MA-FL088-17Sin XG/OX O/S Opaque Door 6'0"X 8'0" +50/-50 3.75 pst' Door -Yes NCTL-210-3849-1/ATLNC 0306.01-17/0308.01-17/W-1843/W-1972 Sin le w/Sidelite g Glazed Sidelite 6.0 psf' Sidelite-No Maximum Panel Size: 3'0" x ST"/Sidelite: 3'0" x 8'0" 8.25 psf' Anchor Details-DWG-MA-FL.0188-17 9.0 pSf4 OXG I/S Opaque Door 910" X 810" +50/-50 0 psf Door -Yes NCTL-210-3849-1/ATLNC 0306.01-17/0308.01-17/W-1972 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0"x 8'0"/Sidelite: 3'0"x 8'0" g Anchor Details-DWG-MA-FLOl88-17 OXO O/S Opaque Door 91011x 8'0" +501-50 3.75 psfl Door -Yes NCTL-210-3849-1/ATLNC 0306.01-17/0308.01-17/W 1843/W-1972 Single w/Sidelites g Glazed Sidelite 6.0 psf' Sidelites-No Maxim""' Panel Si.: 3'0"x 8'0"/Sidelite: 3'0"x 8'0" 8.25 psf Anchor Deails-DWG-MA-F1.0188-17 9.0 pSf 4 OXXO I/S Opaque Door 12'4" x 810" +50/-50 0 psf Door -Yes Wn-210-3849-1/ATLNC 0306.01-17/0308.01-17/W-1972 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 8'W/Sidelite; 3'0" x 8'0" Anchor Details-DWG-MA-FI-0188-17 OXXO O/S Opaque Door 1294" x 890" +50/-50 3.75 psf' Door -Yes Wn-210-3849-1/ATLNC 0306.01-17/0308.01-17/W-1843M-19./2 Double w/Sidelites Glazed Sidelite 6.0 psf' Sidelites-No Maximum Panel Si.: 3'0" x 8'0"/Sidelite: 3'0" x 8'0" 8.25 psf' Anchor Details-DWG-MA-FLOl88-17 8.25 pSf 4 1-Denotes Bumper Outswing Threshold 2 -Denotes &Series Outswing Threshold 3-M-Dam Outswing Threshold 4-Worldwide Pro T4 Threshold National Accreditation & Management Institute, IncJ4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: �� � Lo 1111 MASONITE. 0 00 FIBERGLASS SIDE -HINGED DOOR UNIT —' Q 6'-8" AND 8'-0" OPAQUE SINGLE DOOR cc =� U7 GENERAL NOTES 37.5" MAX. OVERALL FRAME WIDTH W 0 O 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO Z CL THE FLORIDA BUILDING CODE AND WHERE PRESSURE 37.50 MAX. OVERALL FRAME WIDTH REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM W L0 C=..) DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, uj DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 35.75" MAX. Z 2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ), PANEL WIDTH cj).- HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. 35.75" MAX. --{ Q LJ 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, PANEL WIDTH EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), HURRICANE PROTECTVE SYSTEM 1S NOT REQUIRED. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 11 El AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. �o 5. PLASTICS TESTING: TEST DESCRIPTION DESIGNATION FACING o �, zo8 o Cq N N N O O r� m iv[Y 4� 0 * COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 'w 4500 HOURS XENON ARC METHOD 1 ® x o = w w m Addendum to NAW Ceifinalionk:I z Reviewed By: O Dme Review 1 SINGLE DOOR UNIT SINGLE DOOR UNIT w Lir 0 0 z DATE: 4/24/17 .E: N.T.S. Dwc. BY: SWS CHK. BY: FLORIDA P.E. DWG-MA-FLO210-17 #56533 SHEET 1 OF 3 DWG KURT BALTHAZOR DRAWING NO.: SELF IGNITION TEMP ASTM D1929 752 'F > 65D 'F RATE OF BURNING ASTM D635 0.56 IN MIN SMOKE DENSITY ASTM D2843 53.4% TENSILE STRENGTH* ASTM DS38 3.2% DIFF TABLE OF CONTENTS SHEET � DESCRIPTION DESIGN PRESSURE RATING WHERE WATER INFILTRATION PERFORMANCE IS REQUIRED TO BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING OUT5WING INSWING BUMPER O S Z-SERIES 0 S HIGH DAM 0 S X 37.5 +70.0 -70.0 +70.0 -70.0 N A +25.0 -25.0 +40.0 -40.0 +70.0 -70.0 km 0 w U a SEE v> "D" J J M d w of O a im #8 x 2" #8 x 2" 0 to N a �n ui 211 6'-8" HEIGHT UNIT DETAIL "C" DETAIL "D" 1 0,962" 1.375" T T INSWING THRESHOLD BUMPER O/S THRESHOLD 1 1 1.482" f 1.75" 11.047" T T Z—SERIES O/S THRESHOLD HIGH DAM O/S THRESHOLD SEE DETAIL C. 6" �10 x 1" 10 x 1" io N N o w � a SEE DETA "D" v w w 0 � J U G- 8'-0" HEIGHT UNIT SEE DETAIL "C" � 2 C z � O �= y O� m t M x o a rx 4124117 N.T.S. BY: SWS BY: NG NO.: -MA-FLO210-17 2 of 3 1.25" MIN r_nr�y;�•�a�r�.»rm MAXy SHIM TYPICAL MASONRY ANCHOR INSTALLATION 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOAAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. MIN MAX^ SHIM CL i:FrT. TYPICAL WOOD BUCK ANCHOR INSTALLATION HARDWARE SCHEDULE 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE ON 6'-8" HEIGHT UNITS AND AT 10-1/2" CENTERLINE ON 8'-0" HEIGHT UNITS. 2. 4" X 4" FULL MORTISE BUTT HINGES. Lo oCD ¢o o cr =J ti z cn o o 0 zC Lo U DATE: 4 14/j 7 SCALE: N.T.S. oWO. BY: SWS CHK. BY: DRAWING NO.: DWG-MA-FLO210-17 SHEET J OF MIAMI• MIAMI-DADS COUNTY • PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Tubular Skylight, Inc. 753 Cattlemen Road. Sarasota, FL 34232 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida building Code. Polycarbonate Domed Tubular Skylight APPROVAL DOCUMENT: Drawing No. 14009, titled " Polycarbonate Impact Resistant Skylight System ", sheets 1 through 4 of 4, prepared by R & S Professional Engineering, dated January 31, 2014, signed and sealed by Luis A. Rosario, P.E., on March 12, 2015 bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large & Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein and the dome shall be properly marked by GE Plastics. RENEWAL of this NOA shall not be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 14-1028.03 and consists of this page 1, evidence submitted pages E-1, E-2, and E-3 as well as approval document mentioned above. The submitted documentation was reviewed by Hehny A. Makar, P.E., M.S. NOA No.19-1015.13 11 MIDADE COUN Expiration Date: 12/18/2024 1 l Z Ill 9 Approval Date: 11/27/2019 Page 1 Tubular Skylieht, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL NOA 903-0728.01 A. DRAWINGS 1. Drawing No. 03-318, sheets I through 4 of 4, titled "No Titled", prepared by Knezevich & Associates, Inc, dated 07122103, with last revision on 11119103, signed and sealed by V. J. Knezevich, P.E. B. TESTS 1. Test report on Large Missile Impact Test per TAS 201, Cyclic Load Test per TAS 203 and Uniform Static Air Pressure Test per TAS 202, on "Polycarbonate Hemispherical Dome Skylights", specimens Al, A2, Bl, Cl, C2, DI & D2. They were prepared by Construction Testing Corporation, report No. 03-016 dated 07118103, signed and sealed by Y. G. Kuri PE. 2. Test report on Large Missile Impact Test per TAS 201, Cyclic Load Test per TAS 203 and Uniform Static Air Pressure Test per TAS 202, on "Polycarbonate Hemispherical Dome Skylight", specimens Al, A2, Bl, C1, C2, DI & d2. They were prepared by Construction Testing Corporation, No. 03-016, dated 07118103, signed and sealed by Y. G. Kuri, PE. 3. Test report on Uniform Static Air Pressure Test per TAS 202 on "Polycarbonate Hemispherical Dome Skylight", specimen A2, C2 & D2. It was prepared by Construction Testing Corporation report No. 03-016S, dated 10122103, signed and sealed by Y. G. Kuri, PE. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Building Code Compliance Office. E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 03-0924. 01 issued to General Electric Company on 11113103,expiring on 07117108. F. STATEMENTS 1. Code compliance letter issued by Knezevich & Associates, Inc on 07124103, and signed by V. J. Knezevich, PE. 2. No financial interest letter issued by Knezevich & Associates, Inc. on 07124103, and signed by V. J. Knezevich, PE. 17e� �/• /UG.�✓" Helmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No.19-1015.13 Expiration Date: 12/1=024 Approval Date: 11/27/2019 E-1 Tubular Skylight, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 09-0212.01 A. DRAWING 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Building Code Compliance Office E. MATERIAL CERTIFICATIONS 1. None. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 13-1205.01 A. DRAWING 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Florida Building Code, 2010 Edition, Code compliance letter issued by R & S Professional Engineering Services, LLC, dated February 05, 2014, signed and sealed by Luis A. Rosario, P.E. Helmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 19-1015.13 Expiration Date: 12/18/2024 Approval Date: 11/27/2019 E-2 Tubular Skylight, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 14-1028.03 A. DRAWING 1. Drawing No. 14009, titled " Polycarbonate Impact Resistant Skylight System sheets I through 4 of 4, prepared by R & S Professional Engineering, dated January 31, 2014, signed and sealed by Luis A. Rosario, P.E., on 0311212015. B. TESTS 1. Test report on Large Missile Impact Test per TAS 201, Cyclic Load Test per TAS 203 and Uniform Static Air Pressure Test per TAS 202, on "Polycarbonate Hemispherical Dome Skylight", prepared by Architectural Testing, Inc., report No. E3178.01-401-18 dated 01115115, signed & sealed by Shawn G. Collins, P.E. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. FBC, 2010 Edition, Code compliance letter issued by R & S Professional Eng. Services, LLC, dated 02105114, signed & sealed by Luis A. Rosario, P.E. 5. NEW EVIDENCE SUBMITTED A. DRAWING 1. None. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. FBC, 2017 Edition, Code compliance letter issued by R & S Professional Eng. Services, LLC, dated 0912412019, signed and sealed by Luis A. Rosario, P.E. " W � Helmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No.19-1015.13 Expiration Date: 12/18/2024 Approval Date: 11/27/2019 E-3 GENERAL NOTES: 1, THESE APPROVAL DOCUMENTS REPRESENT A POLYCARBONATE IMPACT RESISTANT 12 SKYLIGHT SYSTEM ANALYZED WITH THE PROVISION SET TOR THE ISSUANCE OF A NOTICE OF ACCEPTANCE (NOA) BY MIAMI-DADS COUNTY PRODUCT CONTROL. DIVISION -FOR THE HIGH VELOCITY HURRICANE ZONE (HVHZ) OF THE FLORIDA BUILDING CODE, 2, SKYLIGHT DOMES SHALL BE VACUUM FORMED -FROM CLEAR POLYCARBONATS SHEETS TO A DOME MINIMUM THICKNESS OP 0,0.93" OR .0.118" AS NOTED ON -THESE DRAWINGS. - 3. ALL SKYLIGHT DOME SYSTEMS DEPICTED IN THESE APPROVAL DOCUMENTS ARE RATED FOR THE FOLLOWING DESIGN PRESSURE: - MAX. POSHIVO w 90 P.,5.P - MAX, NEGATIVE (•} 120 P.S.P. 4. MATERIAL SPECIFICATIONS: r POLY -A) ALL POLYCARBONATE DOMES SHALL BE FABRICATED FROM GE LEXAN CARBONATE SHEET NUMBER 9034 AS APPROVED UNDER MIAMI^DADS COUNTY NOTICE OF ACCEPTANCE NUMBER 00-0710.02. SYNTHETIC THERMOPLASTIC POLYMER TENSILE STRENGTH Fy - 8,908 P.S.I., FLEXURAL STRENGTH Fby > 12,900 P.S.S., FLEXURAL MODULUS = 328,700 P.S.S. B) POLYESTER OUTER SEALS SHALL BE THOROUGHLY CURED CLOSED AND OPEN CELL FOAM, 2 LBS PER CUBIC FOOT 14EFTING UL94-HF-I LISTING. 5. A 33% INCREASE IN ALLOWABLE STRESS RAS NOT BEEN USED IN THE DESIGN O$ THIS PRODUCT, , 6. DETERMINE THE POSITIVE & NEGATIVE DESIGN LOADS TO USE, WHEN REFERENCING THESE DOCUMENTS, IN ACCORDANCE WITH THE GOVERNING CODE AND GOVERNING WIND VELOCITY. 7. THESE APPROVAL• DOCUMENTS ARE GENERIC AND DO NOT INCLUDE IHFORMATION FOR•SITE-SPECIFIC APPLICATION OF THIS SKYLIGHT SYSTEM. 8. THESE APPROVAL DOCUMENTS SHALL COMPLY WITH CHAPTER 61GI5-23 OF THE - FLORIDA ADMINISTRATIVE CODE, 9. THESE APPROVAL DOCUMENTS, ARE SUITABLE TO BE APPLIED BY THE CONTRACTOR PROVIDED THE CONTRACTOR DOES NOT DEVIATE FROM THE CONDITIONS DETAILED 'HEREIN AND THE CONTRACTOR VrRIFIES THAT THE EXISTING STRUCTURE DOES • NOT DEVIATE IN EITHER FORM OR MATERIAL FROM THAT DETAILED HERBTN. 10. ANY MODIFICATIONS OR ADDITIONS TO THESE APPROVAL DOCUMENTS WILL VOID THE APPROVAL DOCUMENTS., -" 11. WHEN THE SITE CONDITIONS DEVIATE FROM THESE APPROVAL DOCUMENTS, THE BUILDING OFFICIAL MAY ELECT ONE OF THE FOLLOWING OPTIONS: A) REQUIRE -THAT SITS. SPECIFIC, DOCUMENTS BE PREPARED, SIGNED, DATED AND SEALED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT, WHICH DETAIL AND JUSTIFY THE DEVIATION. SAID DOCUMENTS SHALL -BE SUBMITTED TO THE PRODUCT ENGINEER FOR REVIEW AS A CONDITION TO THE BUILDING OFFICIAL GRANTING THEIR APPROVAL, - B) REQUIRE THAT A ONE-TIME SITE SPECIFIC APPROVAL BE APPLIED FOR AND SECURED F9014 THE MIAMI-DAUB COUNTY PRODUCT CONTROL DIVISION. WHEN THE SITR CONDITION DEVIATIONS,OCCUR WITHIN THE HIGH VELOCITY HURRICANE ZONE AREAS ONLY OPTION "B" SHALL BE ACCEPTED BY••TRE BUILDING OFFICIAL, - - ' 13. PRODUCT SHALL BE PERMANENTLY LABELED AS FOLLOWS: TUBULAR SKYLIGHT, INC. SARASOTA,FLORIDA MIAMbDADBCOUNTY PRODUCTAPPROVAL ALL I-JETAL FLASHING SHALL BE 26 GA, (0,0179" MIN. THICKNESS) STEEL IN ACCORDANC9 OITR ASTH A792 CQ WITH AN AZ6O HOT DIPPED ALUMINUM ZINC ALLOY COATING (GALVALUME)• AL BOLTS, SCREWSAND WASHERS SHALL BE -STAINLESS STEEL WITH A MINIMUM TENSILE STRENGTH OF 60 k.S.I., U,O'.N. ALL INSTALLATIONS OF -THIS SKYLIGHT SYSTEM SHALL FOLLOW THESE -APPROVED DOCUMENTS AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. .ALL ROOFING DBTAILS•�SHALL COMPLY WITH THE PROVISION OF CHAPTER 15 OF THE FLORIDA BUILDING`QODE. ALL SKYLIGHT DOMES SHALL BE INSTALLED TO PROVIDE A MINIMUM CLEARANCE OF 4" ABOV9 THE FINISH ROOF SURFACE OR FINISH ROOF SINGLE• -PLY MEMBRANE 'IN COMPi,IANCE WITH THE PROVISIONS OF THE MIAMI-DADR COUNTY ROOFING PROTOCOL RAS No, ill, SECTION 9.3. FOR -INSULATION AND ROOF TILE, ADD TILE HEIGHT AND INSULATIOM'THICKNESS TO 4" MINIMUM HEIGHT, PRODUCT lU3NRW CID as complyiug with the Florida Building Code Acccpumcc Nof Io28.�3 lixpirai(mt Untof�� ) t Miwni Dad uct C.onk�~ PRODUCT RPNEP'ED as complying with the Florida Building Code ) O ) ,3 Ame tance No __ Expiration Date �4- By ,oar. tin uuF wrm ttuwxar. a np. twrc aww. !rr OEM 1093" OR.118" GE LEXAN CLEAR POLY- DETAIL CARBONATE �.--- --/ (SKYLIOHTA55EME SKYLIGHT 151, Y MIN. I 75" TYP. .COUNTS FLASHI BY OTH MIN., T ROOF O BY OTH DE 418xi-1/ StdS PHI TRUSS STAINLE NG 0 0 l l l R ERS HICK � l o. II 11 111 I1 E l ` ER 4" .020" ALUI, LIP REFLECTIV HEAD TUBE SS STEEL SCREWS @ S" O.C. MAX. (DsChLESTA11 FLAT ROOF MOUNT (STD-F MODEL) .093" OR .118" G£ LEXAN CLEAR POLYCARBONATE SKYLIGHT .75" MIN. x.7S" MIN. POLYESTER K OUTER SEAL (REFERENCE GENERAE NOTE No. 41 #8xi/2" TEK SCREWS C& 10-3/4" D.C. MAX. 24 GA t.0239" MIN.) STAINI STEEL COME STRAP CLAN 26 GA. (.0179" MIN.) x 2.50' WIDE GALVALUME STORM COLLAR TEK SCREWS O.C. MAX. 1p 26 GA (.0179" MIN. TRIM TO FIT (DUN GALVALUME . FLAS (REFERENCE GEN. BY O' NOTE No. 13) ROOF DE .020" ALVM. BY OTHE TU13E OSKYLIGHTASSEMBLY SCALE+ V—'1 0 —" #8x1-1/4" SMS PHILIP TRUSS HEAD STAINLE: STEEL SCREW$ (p S" O.C. MAX., TYP, S POLYCARBONATE DOME PROFILE (STANDARD & FLA7 ROOF MOUNTS) rcZ SC�ET1-1T2"�1'-0" ODOME CLAMP STRAP 5 SCALE+ 4- 1' - 0" CUUAL Dr ALc3, 1 I Y. (S.00" MAX.1 p O 0 0 0 O o ° � p o a 7C t o �o o (� PHILIP TRUSS m y HEAD STAINLESS u 0 STEEL SCREWS 0)° • 5" O.C. MAX., TYP. - 0 I_ 33.00" MAX. Z FLASHING PLAN (STANDARD & FLAT ROOF MOUNTS) )SCALEI i-1/2" = T - 0' 26 GA (A179" MIN,) GALVALUME (REFERENCE GENERAL NOTE No. FLASHING PROFILE y (STANDARD & FLAT ROOF MOUN S) 5CA 11-114" c Y - 0 EW! AX. Q— L ,MP ��) GEN. L.J i/ FRONTVIPW )DOME CLAMP STRAP $TALEI HA F SIZE 093" OR .118" GE LEXAN CLEAR POLY - CARBONATE SKYLIGHT TYP. PRODUCT REN2W ED as complying wish llto Florida ' Building Code Acc.planc° NO [tom • r GZ g : O? F,xpiraliun Ualc�Y�}, _-j7 By C` Midi Dadcyv'A't C.nnlms PRODUCTRENEWED m complying with the Florida Building Codc ppp 1 Acceptance No 4 FjWuatior. Data+l=/-f/-`I+' Miami Bed - ua mr: ll0 mwn w.pal.n AHrtn lum 01d111 STEEL SCREWS @ S" O.C. MAX. (DsChLESTA11 FLAT ROOF MOUNT (STD-F MODEL) .093" OR .118" G£ LEXAN CLEAR POLYCARBONATE SKYLIGHT .75" MIN. x.7S" MIN. POLYESTER K OUTER SEAL (REFERENCE GENERAE NOTE No. 41 #8xi/2" TEK SCREWS C& 10-3/4" D.C. MAX. 24 GA t.0239" MIN.) STAINI STEEL COME STRAP CLAN 26 GA. (.0179" MIN.) x 2.50' WIDE GALVALUME STORM COLLAR TEK SCREWS O.C. MAX. 1p 26 GA (.0179" MIN. TRIM TO FIT (DUN GALVALUME . FLAS (REFERENCE GEN. BY O' NOTE No. 13) ROOF DE .020" ALVM. BY OTHE TU13E OSKYLIGHTASSEMBLY SCALE+ V—'1 0 —" #8x1-1/4" SMS PHILIP TRUSS HEAD STAINLE: STEEL SCREW$ (p S" O.C. MAX., TYP, S POLYCARBONATE DOME PROFILE (STANDARD & FLA7 ROOF MOUNTS) rcZ SC�ET1-1T2"�1'-0" ODOME CLAMP STRAP 5 SCALE+ 4- 1' - 0" CUUAL Dr ALc3, 1 I Y. (S.00" MAX.1 p O 0 0 0 O o ° � p o a 7C t o �o o (� PHILIP TRUSS m y HEAD STAINLESS u 0 STEEL SCREWS 0)° • 5" O.C. MAX., TYP. - 0 I_ 33.00" MAX. Z FLASHING PLAN (STANDARD & FLAT ROOF MOUNTS) )SCALEI i-1/2" = T - 0' 26 GA (A179" MIN,) GALVALUME (REFERENCE GENERAL NOTE No. FLASHING PROFILE y (STANDARD & FLAT ROOF MOUN S) 5CA 11-114" c Y - 0 EW! AX. Q— L ,MP ��) GEN. L.J i/ FRONTVIPW )DOME CLAMP STRAP $TALEI HA F SIZE 093" OR .118" GE LEXAN CLEAR POLY - CARBONATE SKYLIGHT TYP. PRODUCT REN2W ED as complying wish llto Florida ' Building Code Acc.planc° NO [tom • r GZ g : O? F,xpiraliun Ualc�Y�}, _-j7 By C` Midi Dadcyv'A't C.nnlms PRODUCTRENEWED m complying with the Florida Building Codc ppp 1 Acceptance No 4 FjWuatior. Data+l=/-f/-`I+' Miami Bed - ua mr: ll0 mwn w.pal.n AHrtn lum 01d111 FLASHING PLAN (STANDARD & FLAT ROOF MOUNTS) )SCALEI i-1/2" = T - 0' 26 GA (A179" MIN,) GALVALUME (REFERENCE GENERAL NOTE No. FLASHING PROFILE y (STANDARD & FLAT ROOF MOUN S) 5CA 11-114" c Y - 0 EW! AX. Q— L ,MP ��) GEN. L.J i/ FRONTVIPW )DOME CLAMP STRAP $TALEI HA F SIZE 093" OR .118" GE LEXAN CLEAR POLY - CARBONATE SKYLIGHT TYP. PRODUCT REN2W ED as complying wish llto Florida ' Building Code Acc.planc° NO [tom • r GZ g : O? F,xpiraliun Ualc�Y�}, _-j7 By C` Midi Dadcyv'A't C.nnlms PRODUCTRENEWED m complying with the Florida Building Codc ppp 1 Acceptance No 4 FjWuatior. Data+l=/-f/-`I+' Miami Bed - ua mr: ll0 mwn w.pal.n AHrtn lum 01d111 INTERIOR SECTION VIEW A -A ITEMS NOT SHOWN FOR CLARITY: 7, 10-11, 15, 18, 23, 25, 36-37, 39-41 INTERIOR SECTION VIEW B-B VERALL TEMPERED AIRSPACE LAMI ANNEALED GLASS SENTRY GLASS IONOPLAST INTERLAYER ANNEALED GLASS KAFLEX 552 or JRFECT GLAZE "H" 3/4" GLASS BITE a{]YlY®✓✓ 0 / II WONIDOW SYSTEMS 11 l��lunJ 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700 PVC SWING DOOR IMPACT Y Luco W CO U Z m O a � > N Z W cc cr d d 0 W � a U o uJ W Do ME I "{H111118111� PNDREW 144" t No 58201 'F7� r O: :a. r � :9 STATE OF ' 4: yry• �; O R 1 P 0NAC� zz 4/18/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SECTION VIEWS AND GLAZING DETAIL AIDE 09/20/12 VG #: REV.: CWS-817 A :ALE: SHEET 1:2 20F6 493" OR A10" GE LEXAN CLEAR POLY- /-^DETAIL2 .C-ARDONATE (% LIGHTASSOMI SKYLIGHT 75• / "`CCC MIN. 75" TYP. MIN." 7H(CI ROOF DECK BY OTHERS SMS PHILIP ID TRUSS HEAD STAINLESS STEEL SCREWS I& S" O.C. MAX. 0 1 If 11 I o ( Z6 GA 1.0179" MIN.) GALVALUME IREFERENCE GEN. NOTE No.13) �y_W .020" ALUM. REFLECTIVE TUBE OSSTANDARD PLAT ROOF MOUNT, (STD MODEL) Z' CAL2°' .26.GA (.0179" MIN GALVALUME (REFERENCE GEN. 'NOTE No. 131 OSKYLIG11 ASSE'0"MBLY 2 SCAL£r 1093" OR .118" GE LEXAN CLEAR POLYCARBONATE SKYLIGHT .75" MIN, x.75" MIN. POLYESTER 0 OUTER SEAL (REFERENCE GENERAL NOTE No. 41 80x1/2" TEK SCREWS @ 10-3/4" O.C. MAX. 24 GA L0239" MIN.) STAINLESS STEEL DOME STRAP CLAMP . 26 GA. 1.0179" MIN.) x 2.SO" WIDE GALVALUME STORM COLLAR 1L8x1/2" TEK SCREWS @ 16-3/4" O.C. MAX. TRIM TO FIT .020'• ALUM. REFLECTIVE TUBE 75" SSTANDARb &AFLAT ROOp MOUNTS �5FAL-E, 1-1/2- = T - W' _ pOLYCARBONA'CE DOME PLAN O(STANDARD & FLAr ROOF MOUNTS SCAB- /2 A Y - 0". 75" ' .SO" .25" 24 GA 60239"MIN.) STAINLESS STEEL DOiAE STFUUt CLFJr1P. ODOME CLAMP STRAP SCALE, 1-1/2" r 1' - 0' 1.00' 1.00" • EQUAL PA ES, P.1.00 15.00" MAX.) o ° 4 e ° XX o n o R8x1-1/4" SMS PHILIP TRUSS m STAINLESS STEEL SCREWS o ° - 5" O.C, MAX., TYP. ° 0 0 0 0 O 0 0 0 a 36.00•' MAX. _ L PLASHING PLAN O(STANDARD ROOF MOUNT}_ SC Et 1-1/2" = T - 0" GA (.0119" MIN.) GALVALUME fERENCE GENERAL NOTE No, 11 M TO FIT AROUND REFLECTIVE .D93" OR 310" 41XV GE LEXAN SHING PROFILE CLEAR POLY- STANDARD ROOF MOUNT CARBONATE 054A1.: .1/2' - T - 0" 'LSKtjYj�1LI1GHTJLD- ' 1(Bx1/2" TEK SCREW ---•.04)" OR .110" @ 10-3/4" O.C. MAX. GE LEXAN /_24 GA b0239" MIN, 49-0-'SKYLIGHT CLEAR POLY- / STAINLESS STEEL CARBONATE / DOME STRAP CLAMP TRIM 70 FIT Z6 J FO LV (dME MIN.) (REFERENCE GEN. NOTE No. 13) SID.EMEW ODOME CLAMP STRAP KZALEt HA S z PRODUCT RRNB%VBD as complyipg wills (ho Ptor(da Building Codo AccepnmcONu L4, oZ Cj Rxpiratiou Data_),y.�)�. ({t By PRODUCT RENEWED as complying with the Florida Building Cade Acceptance No 101 7, 3 'on Datc �p 4- BY Mwu u Cotttro Mk nW` r twrm )IPIAI(BM A R.m >Ns ewHu OEM limp .093" OR .118" GE LEXAN CLEAR POLY- CAR80NATE SKYLIGHT OTHERS MIN: J" THIC1 Roof DECK 8Y OTHERS DETNL2 /.-----.�(5KYLIOHTA55ffA3LY) I 2.5V TYP. tiiw �� az ( I i ALUM REFL. "K�"j REFLECTIVE TUBE OLO-W P1. SLAT ROOF MOUNT (LRM•C MODEL) SCALEe 2' .093" OR .110" BE LEXAN SECTION 6� CLEAR POLYCARBONATE SKYLIGHT: 60 MIL. POLYVINYL CLORiDE SINGLE -PLY MEFIBRANE \FLASHING (STRETCHEOI i 08x1-1/4" EMS PHILIP TRUSS HEAD STAINLESS STEEL SCREWS Cal \ / 5-1/2" O.C. MAX., TYP. .020" ALUM. REFLECTIVE TUBE ' OSKYLIGHT ASSEMBLY 2 SAE: 3" . 1' - O" 8Y'OTH£RS MIN. J" THICK ROOF DECK BY OTHERS MIN.2X6 WOOD CURB CONNECTED TO ROOF DECKING WITH 1f B x 1.50" GALVANIZER DECK SCREW -WITH NEOPRENE WASHER SPACED 4" FROM EACH CORNER AND 10" O.C. MAX, IN BETWEEN ' POLYCARBONATE 00ME PROFILE O(LOW PROFILE FLAT ROOF MOUNT, 8 SCALE. 1-1/2" c V - 0" L L EQUAL SPACES, TYP. (S.SO" MAX-1 1, 22.00" MAX. • 'DOME DIAMETER H8X1-1/4" SMS- PNILIP TRUSS HEAD STAINLESS• STEEL SCREWS - 5-1/2" O.C. MAX.,:TYP. 27,00" MAX, I POLYCARBONATE DOME PLAN LOW PROFILE FLAT ROOF MOUNT) 4 SCALE: -1/2" - T - O;' DOME DIAMETER / RISE SCHEDULE CLEAR OPENING DIAMETER MAXIMUM DOME RISE -6.25" 4.00" Q.50" 5.00" 14,50" 7.00" 22.00' 10.50" X Q E 1.50" HEM LAP, " ^ OUTLINE OF POLY - CARBONATE DOME MAX. 60 MIL, POLYVINYL CLORIDE SINGLE -PLY MEMBRANE FLASHING BY SEAMAN CORP. APPROVED 13YMDC N.O.A. o# 00.1208.02 (LOW PROFILE FLAT ROOF MOUNT) SCALE: 1- 2" n T - 0" .020" ALUM. - REFLECTIVE TUBE .093" OR .118" GE LEXAN CL•�AR POLYCARBONATE SKYLIGHT 41 POLYVINYL CLURIDE -PLY MEMBRANE NG(STRETCHED) VED BY MDC N.O.A. PRODUCT RENEWED m complying with the Florida Building Colo )) Acceptance Noj4-EGA G3 Rrpitation Dntc Milani D.dcy�Liftct 00111fot flexl-1/4" SM$ODUCT RENEWED sa complying with the Florida - Building Code j Acceptance No Lt- 01 S•) 3 N� tmn Uatc l'L�.A-iZA w HY r% r Dad u Control MIN. 2x6 WOOD CURB BY OTHERS O60 MIL MEMBRANE FLASHING DETAIL 6 sE L , HALP s zE KP.: un alas wrm nuwxcn uue at•uat MIAMI• omm MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamldadeeov/ecoaomv J.A. Taylor Roofing, Inc. 302 Melton Drive Fort Pierce, FL 34982 SCOPE: This NOA is being issued trader the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas, where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tite-Loc Plus 0.032in x 12in thru 18in Wide Aluminum Panel over Wood Deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA-No. 16-0224.04 and consists of pages 1 through 5. The submitted documentation was reviewed by Freddy Semino NOA-No.: 20-1214.06 Expiration Date: 03/24/2026 Approval Date: 02/1112021 Page 1 of 5 ROOFING ASSEMBLY APPROVAL: Category Sub -Category Material: Deck Type: Maximum Design Pressure Roofing Non -Structural Metal Roofing Aluminum Wood —174.25 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Titc-Loc Plus 0.032" Aluminum Panel Tite-Loc Plus Clips (Option 1 & 2) Dimensions Length: varies Width: 12" thru 18" Height: 2" Thickness: 0.032" Min. Yield Strength: 20 ksi. Length: 4.3" Width: 2.145" Height: 2.1" Base Thickness 18ga. Tab Thickness 22ga. EVIDENCE SUBMITTED: Test Agency Architectural Testing, Inc. Intertek I ATI Valspar Test Product Specifications Description TAS 110 Valspar Fluropon coated roll formed 0.032" aluminum interlocking panels. TAS 110 Galvanized Steel, Galvalume Steel or Stainless steel stamped clips for use with Tite-Loc Plus 24 gage steel panel. Test Identifier Test Name/Report Date B8438.02-450-18 TAS 125 09/14/12 74913.01-109-18-rl TAS 100 04/15/15 J5603.01-450-18 TAS 100 08/12/19 C5105.02-801-44 ASTM E2140 04/24/15 433X515 Salt Spray ASTM B 117 43313173 Accelerated Weathering ASTM G 23 NOA-No.: 20-1214.06 Expiration Date: 03/24/2026 Approval Date: 02/11/2021 Page 2 of 5 APPROVED ASSEMBLIES: System A: Tite-Loc Plus 0.032" Aluminum 12" thru 18" Wide Panel Deck Type: Wood, Non -Insulated Deck Description: New Construction 19/32" or greater plywood or wood plank. Slope Range: 2": 12" or greater (1": 12" or greater effective w/2020 FBC 7ih Edition) Maximum Uplift See Table A below Deck Attachment: In accordance with applicable building code, but in no case, it shall be less than #8d ring shank nails spaced at distance listed below in Table A. In re -roofing, where deck is less than 19/32" thick (minimum 15/32") the above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side - laps and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 1V4' annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or any Miami -Dade County Product Control Approved underlayment having a current NOA. Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in PAC Contractors Association's Roofing Installation Manual. Metal Panels and Install the " Tite-Loc Plus 0.032" Aluminum Panel " panels including flashing penetrations, Accessories: valleys, end laps and accessories in compliance PAC Contractors Association's current, published installation instructions and in compliance with the minimum requirements detailed in Roofing Application Standard RAS 133. Tite-Loc panels shall be secured with Tite-Loc Plus clips at a spacing listed below in Table A. Clips are to be fastened with a minimum of two #10 x 1-1/2" long pancake head screws of sufficient length to penetrate through the deck at a minimum of 3/16". Place the female end of the adjacent panel over the clip/panel male assembly and seam 180' degree. See detail herein. Factory or field applied sealant in the seam is optional. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' MaAmum Design Pressures —121.75 psE —174.25 psE Maximum Clip Spacing 2411 o.c. 6" o.c. Maximum Plywood Nail spacing 6" o.c. 3" o.c. 1. Extrapolation shall not be allowed NOA-No.: 20-1214.06 Expiration Date: 03/24/2026 Approval Date: 02/11/2021 Page 3 of 5 SYSTEM LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city, state, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 6. Panels may be shop or jobsite roll formed with machine model #('s) 5521095 and 7031100 from PAC Contractors Association. PROFILE DRAWING 180 DEGREE 2" HIGH X 12" THRU 18" WIDE DOUBLE LOCK PANEL OPTIONAL FACTORY OR FIELD APPLIED SEALANT IN THE SEAM CLIP RELIEFS, STIFFENING RIBS AND STRIATIONS OPTIONAL NOA-No.: 20-1214.06 Expiration Date: 03/24/2026 Approval Date: 02/11/2021 Page 4 of 5 CLIP DETAIL DRAWINGS ISOMETRIC VIEW ___________ O O SIDE VIEW FRONT VIEW CLIP OPTION 1 ISOMETRIC VIEW --------------------------------- O O ANY- 1 SIDE VIEW 1: 1 FRONT VIEW CLIP OPTION 2 END OF THIS ACCEPTANCE NOA-No.: 20-1214.06 Expiration Date: 03/24/2026 Approval Date: 02/11/2021 Page 5 of 5 MI®MMAD MIAMI-DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Owens Corning One Owens CorningParkway Toledo, OH 43659 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Weatherlock® Specialty Tile & Metal Underlayment LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 17-0522.01 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-0523.02 Expiration Date: 07/31/23 Approval Date: 08/02/18 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Sub -Category: Material: Roofing Underlayment SBS TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Weatherlock® 36" x 66.7' rolls TAS 103 SBS self-adbering asphalt sheet material with a Specialty Tile & ASTM D1970 white or green glass reinforced polyester surfacing Metal Underlayment fabric; for use as an underlayment in sloped roof assemblies. MANUFACTURING LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: Test Aeenev PRI Construction Materials Technologies, LLC. Test Identifier OCF-312-02-01 OCF-320-02-01 OCF-426-02-01 OCF-426-02-02 OCF-426-02-04 Test Name/Report ASTM D1623 TAS 103 ASTM D1970 TAS 103 ASTM D1623 Date 07/03/17 06/28/17 07/12/19 07/23/18 07/12/18 NOA No.: 18-0523.02 Expiration Date: 07/31/23 Approval Date: 08/02/18 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated, new construction Deck Description: "/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D226 Type 11 or ASTM D2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of Weatherlock® Specialty Tile & Metal Underlayment with a minimum 3" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Note: When used in Tile roof systems Weatherlock® Specialty Tile & Metal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies NOA No.: 18-0523.02 Expiration Date: 07/31/23 Approval Date: 08/02/18 Page 3 of 4 El 0 0 I , V' AT, m 0 I PARTS F. 28 P-4933 NUT, 3/8"-16 FLANGED W/ SERRATED LIP, SS, @ PANEL McMASTER , 53 lei I_VS�9q=9:1:1:1111? LINE ITEMS NOT USED: 8, 13, 35, 38, 48-49 0 or aV{]YlY®✓✓ 0 / II W�N9DOW SYSTEMS 11 l��lunJ 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700 PVC SWING DOOR IMPACT n w o < 0 0 Y LuCO W CO U Z m O a � > N Z W w O d a 0 W 4= a U o U � W ¢ O Z ,otgvDREW T-*,p J • Y No 58201 'F7� r � :9 STATE OF ' 4u: r�ry• �� O R �iiS/ONApoli�11�0�``. LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 AIDE 09/20/12 VG #: REV.: CWS-817 A :ALE: SHEET 1:1 3 OF 6 LORTATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. Weatherlock® Specialty Tile & Metal underlayment shall be installed in strict compliance with applicable Building Code. 3. Weatherlock® Specialty Tile & Metal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. Weatherlock® Specialty Tile & Metal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over roofing Base/Anchor sheet underlayment. 5. Weatherlock® Specialty Tile & Metal underlayment shall not be left exposed as a temporary roof for longer than 90 days of application. 6. The standard maximum roof pitch for Weatherlock® Specialty Tile & Metal underlayment shall be 6:12 when tiles are loaded directly to the Weatherlock® Specialty Tile & Metal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. Weatherlock® Specialty Tile & Metal underlayment may be used with any approved roof covering Notice of Acceptance listing Weatherlock® Specialty Tile & Metal underlayment as a component part of an assembly in the Notice of Acceptance. If Weatherlock® Specialty Tile & Metal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Weatherlock® Specialty Tile & Metal underlayment shall be applied over the underlayment. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No.: 18-0523.02 Expiration Date: 07/31/23 Approval Date: 08/02/18 Page 4 of 4 4 9/16" .078 1 1 /2" 1 7/16" 2 ;CC 7mF — Ln- 2 15/16" DOOR HEAD-1833 REINF. VERT. - 1777 4 9/16" 062 1 1 /2" 3 DOOR SILL-1878 2 15/16" 1/8" 4 9/16" LU U .078 REINF., VERT. - 1825 9/16" nq's f 1 1/2" y I:10191oc 1k1AI:3ITil 2 15/16 1/8" REINF., HORZ. - 1845 1/4"21/4"� r 45 T .050 FRAME COVER - 1806 PVC DOOR PANEL - 6083 NOTE: ALL EXTRUSIONS ARE 6061-T6 ALUMINUM UNLESS OTHERWISE NOTED. (cuog®m. 5/8" WINDOW SYSTEMS 9/16" L 1900 SW 44TH AVE. OCALA, FLORIDA 34474 42 9/16" 47 WWW.CWS.CC 11/16" 1/16" 1/16 HEAD COVER - 1840 8700 PVC INSERT, FRONT - 5321 SWING DOOR IMPACT 1 1/8" Ln 5/8" o 1 9/16" 46 0 0 7 43 13/16" 1/16" w m + 1/16" DRIP CAP - 1817 U Z m O INSERT, BACK - 5322 a cn N Z w � O Lu d a 0 W � 5/8" 2 7/16" d w � o 44 1 1/16" 51 1 3/16" 1/16" � ¢ Z HRESHOLD - 1783 PVC GLAZING BEAD - 6084 ,+,Pt PNDRE �TItAe �r : No 58201 :1� r � :9 STATE OF ' 4: yry�� • �; O S,0NA11 st,��� z2 4/18/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 EXTRUSIONS AIDE 1 09/20/12 CWS-817 A 'ALE: SHEET 1:2 4 OF 6 ANCHOR AT MIDSP""' 'T 6" MAX. (TYP.) 4" MAX. (TYP.) 12" MAX O.C. (TYP.) ANCHOR LAYOUT 3/16" ANCHORS THRU HINGE (TYP.) (TYP.) NOTE: HINGE SPACINGS ARE: \X. (TYP.) 8-1/2" FROM ENDS 21-5/16" MAX. O.C. FOR UP TO 81" UNIT HEIGHT. 20" MAX. O.C. FOR OVER 81" UNIT HEIGHT. TYP.) NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 4" FOR MASONRY, 2-13/16" FOR HINGES (ALL SUBSTRATES), 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA200(FLANGE WINDOWS), FMA/WDMA250(BOX WINDOWS), FMA/AAMA/WDMA300(EXTERIOR DOORS) aV{]YlY®✓✓ 0 / II WINDOW SYSTEMS 11 l��lunJ 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700 PVC SWING DOOR IMPACT IIIIIIIaIZI 'k "{H111118111� ,otgvDREW 4 t No 58201 'F7� r O: : u r � :9 STATE OF '�: r�ry5; 0 R 1 P %� 45,fto O�A; *G�,,� zz 4/18/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ANCHOR SCHEDULE AND NOTES AIDE 1 09/20/12 CWS-817 A :ALE: SHEET 1:20 5OF6 TYPICAL HEAD ANCHORAGE SUBSTRATE BY OTHERS SEE TABLE 1 PERIMETER SEALANT BYINSTALLER INSIDE AND OUT CONTINOUS DBL 1/4" BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BYINSTALLER. PERIMETER SEALANT BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1 A VERTICAL SECTION 6 TYPICAL SILL ANCHORAGE MIN. EDGE DIST. INTERIOR 1/4" MAX. SHIM aa gom W3 i SEE TABLE 1 MIN. EMBEDMENT WINDOW SYSTEMS SEE TABLE 1 1900 SW 44TH AVE. CONTINOUS DBL 1/4" BEADS OF SEALANT OCALA, FLORIDA 34474 AROUND PERIMETER AT ALL INDICATED WWW.CWS.CC MIN. EMBEDMENT POINTS BETWEEN FRAME AND SUBSTRATE SEE TABLE 1 BYINSTALLER. MIN. EDGE DIST. SEE TABLE 1 8700 PVC INSTALLATION ANCHOR SWING DOOR 1/4" MAX. SHIM SEE TABLE 1 IMPACT Ln INTERIOR T7 o 0 0 HINGE ANCHOR Y INSTALLATION ANCHOR SEE TABLE 1 w CO TABLE 1 HINGE MIN. EDGE DIST. Z SEE TABLE 1 m p \§/ / i a PERIMETER SEALANT BY INSTALLER � Q w INSIDE AND OUT HINGE MIN. EMBEDMENT w SUBSTRATE BY OTHERS SEE TABLE 1 w SEE TABLE 1 rBBHORIZONTAL SECTION o w 6 TYPICAL JAMB / HINGE ANCHORAGE p MIN. EMBEDMENT SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.85 KSI MIN.) 1/4" ELCO ULTRACON 1-3/4" 2-1/2" HOLLOW OR GROUT -FILLED CMU (ASTM C-90) 1/4" ELCO ULTRACON 1-1/4" 2-1/2" 2XMIN. SOUTHERN PINE (G=0.55) 1/4" ELCO ULTRACON 1-3/8" 7/8" 2XMIN. SOUTHERN PINE (G=0.55) #12 WOOD SCREW 1-3/8" 7/8" 16 GAUGE (0.060") MIN. #12-14 HILTI KW IK-FLEXOR ITW FULL THREAD STEEL STUD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" 1/2" 1/8" ALUM. (6063-T5 MIN.) OR #12 GRADE 5 SELF -TAPPING / FULL THREAD 1/8" STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125" 1/2" HINGE ANCHORS INTO CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON 1-3/4" 2-1/2" HINGE ANCHORS INTO HOLLOW OR GROUT -FILLED 3/16" ELCO ULTRACON 1-1/4" 2-1/2" CMU (ASTM C-90) HINGE ANCHORS INTO 2X MIN. SOUTHERN #10 WOOD SCREW 1-3/8" 7/8" PINE (G=0.55) HINGE ANCHORS INTO 16 GAUGE (0.060") MIN. #10-16 HILTI KW IK-FLEXOR ITW FULL THREAD 1/2" STEEL STUD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" HINGE ANCHORS 1/8" ALUM. (6063-T5 MIN.) OR #10 GRADE 5 SELF -TAPPING / FULL THREAD 1/2" 1/8" STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125" IIIIIII¢Izl ,�� t gvD RE Wy T Ai4 �J• No 58201 'F1� r � :9 STATE OF yry�� • ........... z� 4/18/2015 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 INSTALLATION DETAILS AIDE 1 09/20/12 CWS-817 I A SHEET 1:2 6 OF 6 L. Roberto Loftws P.E. 1432 Woodford Rd. Lewisville, NC 27023 434-688-0609 Manufacturer: Masonite Report #: 514009B Date: 10/10/2017 rllom as(ai Irlomaspe.com Test Report: N/A Product., Single door TxF (Wood Frame) scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code 7th edition (2020). Anchor capacity in shear condition: Solid members w/ d w/out gap: a. With threads present in shear plane Fastener type: 910 wood screw (NUS 2018, TR12) Nominal diameter: D: 0,190 in Gap: g: 0,0000 in Root diameter: Dr: 0,152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fro = 80,000 psi Side member: Douglas Fir -Larch (G=0.50) Main member: Spruce -Pine -Fir (6=0.42) Side member thickness: t,= 1.000 in Main member thickness: t.= 1.500 in Side member dowel bearing strength: F. = 4,650 psi Main member dowel bearing strength: Fes„ = 3,350 psi Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: I. = 1.140 in Mode I. Mode L Mode II Mode III. Made 111, Mode IV qm = 636.5 lbs/in qs = 881 lbs/in A: 0.0007 A: 0.00096 A: 0.00107 A: 0.00135 P= 725.61 lbs P= 884 lbs B: 1.07 8: 0.57 B: 0.5 B: 0.000 Ko = 2.400 Ko = 2.400 C:-427.674 C:-253.623 C: -267.699 C: -93.6 Z.= 302 lbs Z,= 368 Ibs P= 331 lbs Ms= 46.8 in-lbs Mm= 46.8 m-lbs Ka = 2.400 P = 297 Ibs P = 319 lbs P = 263 Ibs Min. Design value: Z= 110 Ibs 2= 138 lbs Ka= 2.400 Ko= 2.400 Ko= 2.400 Duration Factor: Co= 1.6 Z= 124 lbs Z= 133 lbs Z= 110 lbs Allowable Design Value (ZCo): Z'= 175 lbs/anchor Fastener type: 1/4 ITW Tapcon Tabulated values N.O.A. 16-1222.06 Substrate: Hollow block edge distance spacing (in) 2.00 4.00 2.00 130 161 4.00 l63 202 Minimum embedment: 1.25 in Actual edge distance: 2.50 in Actual C To C spacing: 3.00 in Allowable Design Value: Z..= 155 lbs/anchor (per interpolation when needed) Fastener type: #10 Tek screw Substrate: 18 6A, Steel Tabulated design value: Z= 1266 lb. Safety factor: Fs= 4 Allowable Design Value (ZFs): Z.= 316 Ibs/anchor Minimum anchor capacity: 155 lbs/anchor Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations, minimum reau)red anchors 36.38 Design pressure: 70.0 psf M 95.25 1 of 3 Zane Arc) (fit) Load (lbs) Ind. (in) Max. O.C. (in) Anchor Result Cap. (Ibs)Qty Load (Ibs) Al 2.3 161 N/A N/A 155 2 80 OK At 9.7 681 6.00 18.00 155 b 114 OK Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P.E. 1432 Woodford Rd. Lewisville, NC 27023 434-688-0609 r1iornasa irlornaspe. co ❑I Anchor Locations: 2 of 3 36.38 9.19 6.00 TYP. 1 6.00 i 6.00 Manufacturer: Masonite Report #: 514009B Date: 10/10/2017 11111111//, ��\ \%�S R L 041���/� t`v •� E N q 90oo *0 51 ••*= ,o �p• • TATE OF i�0.Fs.ZORIDi N ONAL1Ea��`� Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Roberto Lomas P.E. 1432 Woodford Rd. Lewisville, NC 27023 434-688-0609 rlloal as(d)IrIonnaspe.coal Manufacturer: Masonite Report #: 514009B Date: 10/10/2017 Installation Instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 21/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1 X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 3of3 Luis R. Lomas P.E. FL No.: 62514 9/2/2020