Loading...
HomeMy WebLinkAboutBAYSLINGER-MANAUL J&DProject Summary Date: +� wrightsoft Entire House QUICK CALCS, INC. 317 ST. LUCIE LANE, Fr. PIERCE, FL 34946 Phore: 772-066-6799 Email: DUICKCALCS@AOL.COM For: BAYSINGERADDITION 8801 S. INDIAN IRVER DRIVE, FT. PIERCE, FL Notes: Weather: Fort Fierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 OF Inside db 70 °F Inside db 75 OF Design TD 28 °F Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 5252 Btuh Structure 6229 Btuh Ducts 602 Btuh Ducts 799 Btuh Central vent (0 clim) 0 Btuh Central vent (0 cl m) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 5854 Btuh Use manufacturer's data n Rate/swing multipplier Equipmenlsensibleload 0.95 6676 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1110 Btuh Ducts 246 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area(f:2) 184 184 Equipment latent load 1356 Btuh Volume (W) 1840 1840 Airchangesthour 0.61 0.32 Equipment Total Load (Sen+Lat) 8032 Btuh Equiv. AVF (cim) 19 10 Req. total capacity at 0.70 SHR 0.8 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Ducted mini split system Trade Ducted mini split system Model NTXSKH09A 12AA Cond NTXSKH09A 12AA AHRI ref 202392207 Coil NTXDKS09A1 1 2AA AHRI ref 202392207 Efficiency 11 HSPF Efficiency 12.8 EER, 18.8 SEER Heating Input Sensible cooling 6300 Btuh Heatng output 12500 Btuh @ 47-F Latent cooling 2700 Btuh Temperature rise 38 OF Total cooling 9000 Btuh Actual airflow 300 cfin Actual airflow 300 cfin Airflowfactor 0.051 cIm/Btuh Airflowfactor 0.043 cIm/Btuh Static pressure 0.04 in H2O Static pressure 0.04 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point = 20 OF Backup: Input=lkW, Output= 3943 Btuh, 100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft- 2021-Apr-1908:47:40 t1 °- •^^- --- Rigk-SufeO Uriversal 201919.021 RSU08101 Pagel ACC...o its\Wrigllsof HVACrBAYSINGERADDmON.rtp Calc=MJ8 Frort Door faces: N +I+wrightsoft• Right-J® Worksheet Job` Entire House Date: sy: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Prone: 772-066-6799 Email: OUICKCALCS@AOL.COM 1 Room name Entire House BATH 2 E)rosedwall 39.0 It 19.0 ft 3 Room height 10.0 ft 10.0 ft heaftol 4 Room dimensions 11.0 x 8.0 ft 5 Room area 184.0 W 88.0 R Ty Construction U-value Or HTM Area (R) Load Area (fF) Load number (BWhR-°F) (BWh4P) or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 W 12C-Ow 0.091 n 2.55 1.96 240 240 612 470 120 120 306 235 t—G 13A-0as 0.143 n 4.00 2.19 0 -24 -96 -53 0 0 0 0 10A-m 1.670 n 46.76 25.31 24 0 1122 608 0 0 0 0 W 13A4ors 0.143 a 4.00 2.19 80 80 320 175 0 0 0 0 11 V"13A-0as 0.143 w 4.00 2.19 80 56 224 123 80 56 224 123 10A-m 1.670 w 46.76 51.93 24 1 1122 1246 24 1 1122 1246 C 16X19-Omd OA08 1.59 1.37 184 184 292 252 88 88 140 120 F 22A-tpl 0.989 27.69 0.00 184 39 1080 0 88 19 526 0 6 c)AEDe rsion 442 494 Envelope loss/gain 4676 3262 2318 2218 12 a) Infiltration 576 162 288 81 b) Roomventilation 0 0 0 0 13 Internal gains Occupants@ 230 4 805 0 0 Applianceslolher 2000 0 Subtotal(lines6 to 13) 5252 6229 2606 2299 LasseAemal load 0 0 0 0 Lasstansfer 0 0 0 0 Redistibution 0 0 0 0 14 Subtotal 5252 6229 2606 2299 15 Ductloads 11% 13% 602 799 11% 13% 299 295 Total room load 5854 7027 2905 2594 Arrequired(thn) 300 300 149 ill Calculations approved byACCAto meet all requirements of Manual J 8th Ed. z #f 2021-Apr-1908:47:40 Riglt-Sine®Unvem l201919.021 RSLI08101 Page 1 ...o rls\Wrigltsoft HVACeAVSINGERADDRION.np Calc=MJ8 FrortDoortamv. IN +I+wrightsoft• Right-J® Worksheet Job: Entire House Date: sy: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-066-6799 Email: OUICKCALCS@AOL.COM 1 Room name KrTCHEN 2 Exoosedwall 20.01t 3 Room height 10.0 It heaUmol 4 Room dimensions 12.0 x 8.0 It 5 Room area 96.0 IP Ty Construction U-value Or HTM Area (IF) Load Area Load number (BIuh/W--n (Btruh4F) or perimeter (ft) (Bbh) or perimeter Heat Cool Gross NIPS Heat Cool Gross NiPS Heat Cool 6 W 12C-Ow 0.091 n 2.55 1.96 120 120 306 235 t—G 13A-4ors 0.143 n 4.00 2.19 0 -24 -96 -53 10A-m 1.670 n 46.76 25.31 24 0 1122 608 W 13A-0as 0.143 a 4.00 2.19 80 80 320 175 11 V"13A-4ors 0.143 w 4.00 2.19 0 0 0 0 10A-m 1.670 w 46.76 51.93 0 0 0 0 C 16X19-Omd 0.408 1.59 1.37 96 96 152 131 F 22A-tpl 0.989 - 27.69 0.00 96 20 554 0 6 c)AEDe rsion -52 Envelope lossgain 2358 1044 12 a) Infiltration 288 81 b) Roomventilation 0 0 13 Internal gains Occupants@ 230 4 805 Applianceslolher 2000 Subbtal(lines6 to 13) 2646 3930 Less ebemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2646 3930 15 Ductloads 1 11% 13% 303 504 Total room load 2950 4433 Ar required (Qm) 151 189 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. z #f wrl9tr+tsofi 2021-Apr-1908:47:40 RigH-SuteOUriveraa1201919.021 RSLI08101 Paget ...o its\Wrigf4soft HVACeAVSINGERADDRION.np Calc=MJ8 FrortDoorfaces: N S System stem Summary Date: +I+ wrightsoft Dy ry Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 PIore: 772466-6799 Email: OUICKCALCS@AOL.COM For: External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest fiction rate Actual airflow Total effective length (TEL) BAYSINGERADDITION 8801 S. INDIAN IRVER DRIVE, FT. PIERCE, FL Heating 0.04 in H2O 0 in H2O 0.04 in H2O 0.020/0.020 in H2O 0.040 in/100ft 300 chn f[171tiii Cooling 0.04 in H2O 0 in H2O 0.04 in H2O 0.020/0.020 in H2O 0.040 in/100ft 300 cliin Design Htg Clg Design Diam H x W Dud Actual Ftg.Egv Name (Btuh) (ctm) (cliin) FIR (in) (in) Mat Ln (it) Ln (it) Trunk BATH In 2905 149 111 0.040 7.0 OxO V1Fx 5.1 95.0 KfrCHEN c 4433 151 189 0.040 &0 OxO V1Fx 6.1 95.0 Name Grille Size (in) Htg (cfin) Clg (cfin) TEL (it) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mal Trunk rb1 Ox0 300 300 0 0 0 0 Ox 0 MFx BoMMauc vahce have beenmanuaCy ovenkiden wrightsoR' -. ..., 1", Rigtt-SLMOUriveraa1201919.021 RSU08101 ...ocrwn6\WrigHsoR HVACOAYSINGERADDfIION.np Calc=MJ8 Front Door faces N 202 1 -Apr-1 9 08:47:40 Page 1