Loading...
HomeMy WebLinkAboutRevision-underlayment OFFICE USE ONLY: / DATE FILED: PERMIT# e2�b 2 REVISION FEE: RECEIPT# C>2 PLANNING & DEVELOPMENT SERVICES BUILDING& CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITEE c,/ ADDRESS: --7 / & &'e �'in a^ �'c� a ( L) DETAILED DESCRIPTION OF PROJECT REVISIONS: // CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME): FAX: OWNER/BUILDER INFORMATION: NAME: 4-7 ADDRESS: CITY: STATE: �c ZIP: PHONE(DAYTIME: '7-2 Z 7 70 3? (I FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): I f Revised 06130117 s Z 40 ,,reg istryuo 2 9824 520EdbNrghDriveCREEK Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING COW&EMJ220) Manufacturer: G.A.P. ROOFING, INC. I ued June 9, 2021 4444 Hunt Street File 60Py Pryor, OK 74361 HEVIEWED FUR(800)880-9808 www.gapr°°'",g.Us +ODE COMPLIANCE Manufacturing Location: Pryor, OK ST. LU IE CO Nr Quality Assurance: Keystone Certifications ,Inc. (QUA1824) OCC 7/1 SCOPE Category: Roofing Subcategory: Underlayments Code Edition: Florida Building Code, 71"Edition (2020)including High-Velocity Hurricane Zones(HVHZ) Code Sections: 1507.1.1, 1507.3.3, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) GAPR-014-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) GAPR-018-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) GAPR-029-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) GAPR-030-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies(TST5878) GAPR-034-02-01 ASTM D 1623 2017 PRI Construction Materials Technologies(TST5878) GAPR-034-02-01.1 TAS 103 2020 PRI Construction Materials Technologies(TST5878) GAPR-034-02-02 TAS 110 2000 PRI Construction Materials Technologies(TST5878) 1047T0001 ASTM D 1970 2015a PRI Construction Materials Technologies TST5878 1047T0004.1 TAS 110 2000 9 (TST5878) TAS 103 2020 PRI Construction Materials Technologies(TST5878) 1047T0011 TAS 110 2000 TAS 103 2020 PRI Construction Materials Technologies(TST5878) 1047T0012 TAS 110 2000 PRI Construction Materials Technologies(TST5878) 1047T0016 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) 1047T0017 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) 1047T0018.1 TAS 103 2020 PRI Construction Materials Technologies(TST5878) 1047T0029 ASTM D 1623 2017 TAS 103 2020 PRI Construction Materials Technologies(TST5878) 1047T0035 ASTM D 1623 2017 TAS 103 2020 PRI Construction Materials Technologies(TST5878) 1047T0046 UL1897 2012 ASTM D 903 1998(2010) b e GAP17001.7 FL22853-R8 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. f , CREEK G.A.P. ROOFING,INC. WaterGuard Underlayments TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE WaterGuard WaterGuard Self-Adhered MetalGuard HT is a nominal 60-mil thick ASTM D 1970 self-adhered Self-Adhered underlayment constructed with a SBS polymer modified asphalt top coating and a non-abrasive MetalGuard HT UV stable, anti-skid polymer film. The product is supplied in 2 sq. rolls with nominal dimensions of 36-in, x 67-ft. Exposure on the roof deck shall be limited to a maximum 30 days. WaterGuard WaterGuard Self-Adhered MetalGuard HT MW is an ASTM D 1970, TAS 103, and FRSA/TRI Self-Adhered Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant self- MetalGuard HT adhered underlayment constructed with a SIBS polymer modified asphalt top coating and a non- MW abrasive UV stable, anti-skid polymer film. The product is supplied in rolls having nominal dimensions of 39 3/8-in. x 66-ft. Exposure on the roof deck shall be limited to a maximum 180 days. Tiles shall be placed on battens for all roof slopes. WaterGuard WaterGuard Self-Adhered MetalGuard Trax is a nominal 60-mil thick ASTM D 1970 self- Self-Adhered adhered underlayment constructed with a dual SBS polymer formulation and a non-woven, high MetalGuard Trax temp, UV stable, anti-skid synthetic surface. The product is supplied in rolls having nominal dimensions of 36-in, x 67-ft. Exposure on the roof deck shall be limited to a maximum 120 days. WaterGuard WaterGuard Rain & Ice is a nominal 55-mil thick ASTM D 1970 self-adhered underlayment Rain & Ice constructed with a SBS polymer modified asphalt top coating and surfaced with a sand release agent. The product is supplied in 2 sq. rolls with nominal dimensions of 36-in x 67-ft. Exposure on the roof deck shall be limited to a maximum 30 days. WaterGuard WaterGuard Self-Adhered TileGuard HT is a nominal 80-mil thick ASTM D 1970, TAS 103, and Self-Adhered FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition TileGuard HT compliant self-adhered underayment constructed with a dual SBS polymer formulation and a non-woven, high temp, UV stable, anti-skid polyester top surface. The product is supplied in 2 sq. rolls with nominal dimensions of 39 3/8-in x 66-ft. Exposure on the roof deck shall be limited to a maximum 180 days. The maximum roof slope shall be 6:12 when the roof tiles are placed directly on the underlayment. Tiles shall be placed on battens for roof slopes greater than 6:12. WaterGuard WaterGuard Self-Adhered TileGuard Ultra is a nominal 80-mil thick ASTM D 1970, TAS 103, Self-Adhered and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition self- TileGuard Ultra adhered underlayment constructed with a dual SBS polymer formulation and a non-woven, high temp, UV stable, polyester reinforced top surface. The product is supplied in 2 sq. rolls with nominal dimensions of 39 3/8-in x 66-ft. Exposure on the roof deck shall be limited to a maximum 30 days. The maximum roof slope shall be 6:12 when the roof tiles are placed directly on the underlayment. Tiles shall be placed on battens for roof slopes greater than 6:12. GAP17001.7 FL22853-R8 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK G.A.P. ROOFING,INC. WaterGuard Underlayments TECHNICAL SERVICES, LLC PRODUCT APPLICATION Min. Roof Slope: 2:12 in accordance with the FBC Roof Deck: Plywood decks shall be in accordance with the FBC requirements. Roof decks shall have no more than 1/8"gap at abutting joints. Application: All underlayments shall be installed in accordance with the FBC and the manufacturer's installation requirements. Substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the substrate shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The WaterGuard underlayments shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the substrate. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with 4" headlaps (MetalGuard and Rain & Ice only) or 3" headlaps (TileGuard) and minimum 6" end laps staggered min. 6-ft.from preceding course. In the HVHZ, the WaterGuard underlayments shall be installed over one of more plies of ASTM D 226 Type II or ASTM D 2626 organic felt with minimum 4" headlaps and minimum 6"endlaps in accordance with FBC Section 1518.3. It is permissible to backnail the WaterGuard underlayments 12-inches o.c. within the headlaps (nails shall be installed perpend icular to deck with the nail heads flush to the top surface of the underlayment). Min. Application 40oF and rising; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. Roof Coverings: All WaterGuard underlayments are permitted to be used with mechanically fastened metal roofing, slate shingles, asphalt shingles, photovoltaic shingles, and composite plastic shingles in accordance with the FBC. WaterGuard Self-Adhered MetalGuard HT MW is permitted to be used with mechanically fastened clay and concrete tiles set on battens only in accordance with the FBC. WaterGuard Self-Adhered TileGuard Ultra is permitted to be used with mechanically fastened clay and concrete tiles in accordance with the FBC. WaterGuard Self-Adhered TileGuard HT is permitted to be used with mechanically fastened clay and concrete roof tiles or clay and concrete roof tiles set in the following roof tile adhesive in accordance with the FBC. 1. DuPont TILE BONDTA4 Roof Tile Adhesive 2. DAP Touch'n Seal Storm Bond Roof Tile Adhesive 3. ICP Adhesives Polyset AH-160 GAP17001.7 FL22853-R8 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i CREEK G.A.P. ROOFING,INC. WaterGuard Underlayments TECHNICAL SERVICES. LLC WIND RESISTANCE OF ROOF TILE UNDERLAYMENT SYSTEMS The Allowable Design Pressures below shall be used in accordance with the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition for the selected underayment system. The Allowable Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. System No. 1 Direct Deck application Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: WaterGuard Self-Adhered MetalGuard HT MW, WaterGuard Self-Adhered TileGuard Ultra or WaterGuard Self-Adhered TileGuard HT shall be self-adhered to the deck in accordance with manufacturer's installation instructions. The underlayment may be optionally backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1- 5/8-inch 0 tin caps spaced 12" o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Allowable Design Pressure: -90 psf GENERAL LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 3) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 4) All headlaps shall be installed to shed water from the deck. 5) The underlayment may be used as described in other current FBC product approval documents. 6) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. GAP17001.7 FL22853-R8 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. r CREEK G.A.P. ROOFING,INC. WaterGuard Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 7ch Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. -FkY R• AR'�i, This item has been C•E•N • ' .�F ��� digitally signed and 2021 .06.09 sealed by Zachary R. No 74021 Priest, PE,on 6/9/2021. * : :.* : 10:18:21 _ * = Printed copies of this _04�00� p; document are not STATE OF considered signed and O sealed and the signature Zachary R. Priest, P.E. p R `O P' \ must be verified on any Florida Registration No. 74021 � NAI ElpN� electronic copies. Organization No. ANE9641 1111111 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT GAP17001.7 FL22853-R8 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.