Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential' Performance Method Project Name: Lobo Residence Builder Name: 1, Street: 4704 Paleo Pines Circle Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Nancy Lobo Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type42199.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1900.60 ft2 b. Frame -Wood, Exterior R=11.0 298.67 ftZ 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (2103.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2103.00 ft2 6. Conditioned floor area above grade (ft2) 2103 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(372.7 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: AHU R ft2 6 80 a. U-Factor: Sgl, U=0,65 372.65 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 36.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 7.712 ft. 14. Heating systems -kBtu/hr Efficiency Area Weighted Average SHGC: 0.300 a. Electric Strip Heat 27.0 COP:1.00 B. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2102.5 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2102.50 ft2 b. Conservation features b. NIA R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.177 Total Proposed Modified Loads: 68.39 PASS Total Baseline Loads: 69.62 I hereby certify that the plans and specifications covered by Review of the plans and OollE Sr�T� this calculation are in compliance with the Florida Energy specifications covered by this 1+ _ ; ., Off, Code. calculation indicates compliance �O with the Florida Energy Code. `01 PREPA Before construction is completed c� - DATE: this building will be inspected for compliance with Section 553.908 'q?1 - a I hereby certify that this buildi as designed is in ompliance Florida Statutes. COD with the Florida Energ WE OWNER/AGEN ' BUILDING OFFICIAL: DATE: ' DATE: Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested In accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 2/23/2021 5:15 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT 5UMMARY GNEGKLI5T REPVRT PROJECT Title: Lobo Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2103 Lot # Owner Name: Nancy Lobo Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4704 Paleo Pines Circle Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce, Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2103 19768.2 SPACES Number Name Area Volume Ktchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bedroom 316 2970.4 No 2 1 1 Yes Yes Yes 2 Master Bath 212 1992.8 No 0 1 Yes Yes Yes 3 Office 132 1240.8 No 2 1 Yes Yes Yes 4 Foyer 66 620.4 No 0 1 Yes Yes Yes 5 Laundry 84 789.6 No 0 1 Yes Yes Yes 6 Pantry 32 300.8 No 0 1 No Yes Yes 7 Hall 16 150.4 No 0 1 No Yes Yes 8 Hall 16 150 No 0 1 No Yes Yes 9 Bedroom 2 165 1551 No 1 1 1 Yes Yes Yes 10 Bath 60 564 No 0 1 Yes Yes Yes 11 Bedroom 1 221 2077.4 No 0 1 1 Yes Yes Yes 12 Dining 170 1598 No 0 1 Yes Yes Yes 13 Family Room 272 2556.8 No 2 1 Yes Yes Yes 14 Kitchen 303 2848.2 Yes 2 1 Yes Yes Yes 15 AHU 8 75.2 No 0 1 No Yes Yes 16 Hall 30 282 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bedroom 46 ft 316 ftZ ___ 1 0 0 2 Slab -On -Grade Edge Insulatio Master Bath 33 It 212 ftz ___ 1 0 0 2/23/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type F-= Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab -On -Grade Edge Insulatio Office 12 ft 132 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulatio Foyer 6 ft 66 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulatio Laundry 12 ft 84 ft2 -___ 1 0 0 6 Slab -On -Grade Edge Insulatio Pantry 1 It 32 ft2 __ 1 0 0 7 Slab -On -Grade Edge Insulatio Hall 1 1 ft 16 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulatio Hall 2 1 ft 16 ft2 __-_ 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 2 11 ft 165 ft2 ____ 1 0 0 10Slab-On-Grade Edge Insulatio Bath 6 ft 60 ft2 ____ 1 0 0 11Slab-On-Grade Edge Insulatio Bedroom 1 30 ft 221 ft2 ---_ 1 0 0 12SIab-On-Grade Edge Insulatio Dining 24 ft 170 ft2 ____ 1 0 0 13Slab-On-Grade Edge Insulatio Family Room 16 ft 272 ft2 __-- 1 0 0 14SIab-On-Grade Edge Insulatio Ktchen 5.8 It 302.5 1t2 ____ 1 0 0 15SIab-On-Grade Edge Insulatio AHU 1 ft 8 ft2 ___ 1 0 0 16Slab-On-Grade Edge Insulatio Hall 3 1 ft 30 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2278 ft2 0 ft2 Light N 0.6 No 0.9 No 20 22.62 ATTIC RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Unvented 0 2103 ft2 N N 2/23/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Master Bedroom 0 Blown 316 ft2 0.1 Wood 2 Under Attic (Unvented) Master Bath 0 Blown 212 ft2 0.1 Wood 3 Under Attic (Unvented) Office 0 Blown 132 ft2 0.1 Wood 4 Under Attic (Unvented) Foyer 0 Blown 66 ft2 0.1 Wood 5 Under Attic (Unvented) Laundry 0 Blown 84 ft2 0.1 Wood 6 Under Attic (Unvented) Pantry 0 Blown 32 ft2 0.1 Wood 7 Under Attic (Unvented) Hall 1 0 Blown 16 ft2 0.1 Wood 8 Under Attic (Unvented) Hall 2 0 Blown 16 ft2 0.1 Wood 9 Under Attic (Unvented) Bedroom 2 0 Blown 165 ft2 0.1 Wood 10 Under Attic (Unvented) Bath 0 Blown 60 ft2 0.1 Wood 11 Under Attic (Unvented) Bedroom 1 0 Blown 221 ft2 0.1 Wood 12 Under Attic (Unvented) Dining 0 Blown 170 ft2 0.1 Wood 13 Under Attic (Unvented) Family Room 0 Blown 272 ft2 0.1 Wood 14 Under Attic (Unvented) Kitchen 0 Blown 303 ft2 0.1 Wood 15 Under Attic (Unvented) AHU 0 Blown 8 ft2 0.1 Wood 16 Under Attic (Unvented) Hall 3 0 Blown 30 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space 1 N Exterior Concrete Block - Int InsMaster Bedro 4.1 16 0 9 5 150.7 ft2 0 0 0.5 0 2 E Exterior Concrete Block - Int InsMaster Bedro 4.1 8 0 9 5 75.3 ft2 0 0 0.5 0 3 S Exterior Concrete Block - Int InsMaster Bedro 4.1 1 0 9 5 9.4 ft2 0 0 0.5 0 4 W Exterior Concrete Block - Int InsMaster Bedro 4.1 21 0 9 5 197.8 ft2 0 0 0.5 0 5 E Exterior Concrete Block - Int InstHllaster Bath 4.1 3 0 9 5 28.3 ft2 0 0 0.5 0 6 S Exterior Concrete Block - Int InsWaster Bath 4.1 12 0 9 5 113.0 ft2 0 0 0.5 0 7 W Exterior Concrete Block - Int Instlillaster Bath 4.1 18 0 9 5 169.5 11:2 0 0 0.5 0 8 S Exterior Concrete Block - Int Insul Office . 4.1 12 0 9 5 113.0 ft2 0 0 0.5 0 9 S Exterior Concrete Block - Int Insul Foyer 4.1 6 0 9 5 56.5 ft2 0 0 0.5 0 _ 10 S Exterior Concrete Block - Int Insul Laundry 4.1 12 0 9 5 113.0 ft2 0 0 0.5 0 11 E Exterior Concrete Block - Int InsuBedroom 2 4.1 11 0 9 5 103.6 ft2 0 0 0.5 0 12 E Exterior Concrete Block - Int Insul Bath 4.1 6 0 9 5 56.5 ft2 0 0 0.5 0 13 N Exterior Concrete Block- Int InsuBedroom 1 4.1 15 0 9 5 141.3 ft2 0 0 0.5 0 14 E Exterior Concrete Block - Int InsuBedroom 1 4.1 15 0 9 5 141.3 ft2 0 0 0.5 0 _ 15 N Exterior Concrete Block - Int Insul Dining 4.1 12 0 9 5 113.0 ft2 0 0 0.5 0 16 W Exterior Concrete Block - Int Insul Dining 4.1 12 0 9 5 113.0 ft2 0 0 0.5 0 _ 17 N Exterior Concrete Block - Int Ins6hmily Room 4.1 16 0 9 5 150.7 ft2 0 0 0.5 0 _ 18 NW Exterior Concrete Block - Int Insul Kitchen 4.1 5 10 9 5 54.9 ft2 0 0 0.5 0 19 S Exterior Frame - Wood Bedroom 2 11 15 9 4 140.0 ft2 0.23 0.5 0 20 S Exterior Frame - Wood Kitchen 11 6 9 4 56.0 ft2 0.23 0.5 0 _21 E Exterior Frame - Wood Hall 1 11 4 9 4 37.3 ft2 0.23 0.5 0 _22 E Exterior Frame - Wood Laundry 11 7 9 4 65.3 ft2 0.23 0.5 0 2/23/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Kitchen None .39 3 6 8 20 1`1:2 WINDOWS Orientation shown is the entered Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.3 Y 61.5 ft2 10 ft 0 in 1 ft4 in None None 2 W 4 Metal Low-E Single Yes 0.65 0.3 Y 30.0 ft2 1 ft 5 in 1 ft 4 in None None 3 S 6 Metal Low-E Single Yes 0.65 0.3 Y 12.0 ft2 1 ft 5 in 1 ft 4 in None None 4 W 7 Metal Low-E Single Yes 0.65 0.3 Y 6.0 ft2 1 ft 5 in 1 ft 4 in None None 5 S 8 Metal Low-E Single Yes 0.65 0.3 Y 12.0 ft2 1 ft 5 in 1 ft 4 in None None 6 S 9 Metal Low-E Single Yes 0.65 0.3 Y 24.0 ft2 4 ft 0 in 1 ft 4 in None None 7 S 9 Metal Low-E Single Yes 0.65 0.3 Y 16.0 ft2 4 ft 0 in 1 ft4 in None None 8 S 10 Metal Low-E Single Yes 0.65 0.3 Y 10.0 ft2 1 ft5 in 1 ft4 in None None 9 E 11 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ft2 1 ft5 in 1 ft4 in None None 10 E 12 Metal Low-E Single Yes 0.65 0.3 Y 6.0 ft2 1 ft 5 in 1 ft4 in None None 11 N 13 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ft2 1 ft5 in 1 ft4 in None None 12 N 15 Metal Low-E Single Yes 0.65 0.3 Y 30.0 ft2 1 ft5 in 1 ft 4 in None None 13 W 16 Metal Low-E Single Yes 0.65 0.3 Y 15.0 ft2 4 ft 0 in 1 ft 4 in None None 14 N 17 Metal Low-E Single Yes 0.65 0.3 Y 82.0 ft2 16 ft 0 in 1 ft 4 in None None 15 NW 18 Metal Low-E Single Yes 0.65 0.3 Y 20.5 ft2 14 ft 0 in 1 ft 4 in None None 16 NW 18 Metal Low-E Single Yes 0.65 0.3 Y 8.5 ft2 14 ft 0 in 1 ft 4 in None None 17 NW 18 Metal Low-E Single Yes 0.65 0.3 Y 9.1 ft2 14 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 -32 It 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgIA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000358 1976.8 108.45 203.61 .1155 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 2/23/2021 5:15 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 36 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply --- --- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 80 ft2 Attic 20 ft2 Prop. Leak Free AHU -- cfm 63.1 cfm ' 0.03 0.50 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb IdJan € F M �X� Mar A pr MayX� Jun f Jul Aug ri Sep ri � Oct Oct X Nov Nov Dec DecJun Venting eb Apr May l[ Jul Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 66 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Office, Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 lbs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 1 Default(8 lbs/sq.ft. ft2 ft 0.3 Dining 2/23/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ftz ft 0.3 Family Room Default(8 Ibs/sq.ft. ftz ft 0.3 Kitchen Default(8 lbs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/s .ft. ftz ft 0.3 Hall 3 A 2/23/2021 5:15 PM 7.0.00 - FlaRes2020 FBC 7th Edition'(2020) Compliant Software Page 7 of 7 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA A TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lobo Residence Builder Name: Street: 4704 Paleo Pines Circle Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Y U Owner: Nancy Lobo Jurisdiction: St. Lucie County = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and i continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and We shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend e and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be Installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids betwegn fire sprinkler cover plates and wallsor ceilongs. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/23/2021 5:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 4704 Paleo Pines Circle, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1900.60 ft2 b. Frame -Wood, Exterior R=11.0 298.67 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2103.00 ft2 6. Conditioned floor area (ft2) 2103 b. N/A R= ft2 7. Windows** Description Area c. N/A R= 2 a. U-Factor: Sgl, U=0.65 372.65 ft2 12. Ducts, location &insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: AHU 6 80 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 36.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 7.712 ft. Area Weighted Average SHGC: 0.300 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2EF:0.95 a. Electric SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2102.50 ft2 Credits (Performance method) CF, Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code m liant features. Builder Signature: Date: �� x Address of New Home:G',r City/FL Zip: 14 [ '' ,3�t lSi n E k a c p SHE ST" 2'. 0 4- a° 4 D Wos *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2123/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1