HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential' Performance Method
Project Name: Lobo Residence
Builder Name:
1, Street: 4704 Paleo Pines Circle
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner: Nancy Lobo
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type42199.3 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1900.60 ft2
b. Frame -Wood, Exterior
R=11.0 298.67 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
11. Ceiling Types (2103.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2103.00 ft2
6. Conditioned floor area above grade (ft2) 2103
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(372.7 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU
R ft2
6 80
a. U-Factor: Sgl, U=0,65 372.65 ft2
SHGC: SHGC=0.30
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
36.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 7.712 ft.
14. Heating systems
-kBtu/hr Efficiency
Area Weighted Average SHGC: 0.300
a. Electric Strip Heat
27.0 COP:1.00
B. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2102.5 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2102.50 ft2
b. Conservation features
b. NIA R= ft2
None
c. N/A R= ft2
16. Credits
CF, Pstat
Glass/Floor Area: 0.177 Total Proposed Modified Loads: 68.39
PASS
Total Baseline Loads: 69.62
I hereby certify that the plans and specifications covered by
Review of the plans and
OollE Sr�T�
this calculation are in compliance with the Florida Energy
specifications covered by this
1+ _ ; ., Off,
Code.
calculation indicates compliance
�O
with the Florida Energy Code.
`01
PREPA
Before construction is completed
c� -
DATE:
this building will be inspected for
compliance with Section 553.908
'q?1 - a
I hereby certify that this buildi as designed is in ompliance
Florida Statutes.
COD
with the Florida Energ
WE
OWNER/AGEN '
BUILDING OFFICIAL:
DATE: '
DATE:
Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested In accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
2/23/2021 5:15 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020
INPUT 5UMMARY GNEGKLI5T REPVRT
PROJECT
Title:
Lobo Residence
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2103
Lot #
Owner Name:
Nancy Lobo
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
4704 Paleo Pines Circle
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2103
19768.2
SPACES
Number
Name
Area
Volume Ktchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
Master Bedroom
316
2970.4 No
2
1
1
Yes
Yes
Yes
2
Master Bath
212
1992.8 No
0
1
Yes
Yes
Yes
3
Office
132
1240.8 No
2
1
Yes
Yes
Yes
4
Foyer
66
620.4 No
0
1
Yes
Yes
Yes
5
Laundry
84
789.6 No
0
1
Yes
Yes
Yes
6
Pantry
32
300.8 No
0
1
No
Yes
Yes
7
Hall
16
150.4 No
0
1
No
Yes
Yes
8
Hall
16
150 No
0
1
No
Yes
Yes
9
Bedroom 2
165
1551 No
1
1
1
Yes
Yes
Yes
10
Bath
60
564 No
0
1
Yes
Yes
Yes
11
Bedroom 1
221
2077.4 No
0
1
1
Yes
Yes
Yes
12
Dining
170
1598 No
0
1
Yes
Yes
Yes
13
Family Room
272
2556.8 No
2
1
Yes
Yes
Yes
14
Kitchen
303
2848.2 Yes
2
1
Yes
Yes
Yes
15
AHU
8
75.2 No
0
1
No
Yes
Yes
16
Hall
30
282 No
0
1
No
Yes
Yes
FLOORS
#
Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio Master Bedroom 46 ft
316 ftZ
___
1 0
0
2 Slab -On -Grade Edge Insulatio Master Bath 33 It
212 ftz
___
1 0
0
2/23/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
F-=
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
3 Slab -On -Grade Edge Insulatio
Office
12 ft
132 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulatio
Foyer
6 ft
66 ft2
____
1
0
0
5 Slab -On -Grade Edge Insulatio
Laundry
12 ft
84 ft2
-___
1
0
0
6 Slab -On -Grade Edge Insulatio
Pantry
1 It
32 ft2
__
1
0
0
7 Slab -On -Grade Edge Insulatio
Hall 1
1 ft
16 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulatio
Hall 2
1 ft
16 ft2
__-_
1
0
0
9 Slab -On -Grade Edge Insulatio
Bedroom 2
11 ft
165 ft2
____
1
0
0
10Slab-On-Grade Edge Insulatio
Bath
6 ft
60 ft2
____
1
0
0
11Slab-On-Grade Edge Insulatio
Bedroom 1
30 ft
221 ft2
---_
1
0
0
12SIab-On-Grade Edge Insulatio
Dining
24 ft
170 ft2
____
1
0
0
13Slab-On-Grade Edge Insulatio
Family Room
16 ft
272 ft2
__--
1
0
0
14SIab-On-Grade Edge Insulatio
Ktchen
5.8 It
302.5 1t2
____
1
0
0
15SIab-On-Grade Edge Insulatio
AHU
1 ft
8 ft2
___
1
0
0
16Slab-On-Grade Edge Insulatio
Hall 3
1 ft
30 ft2
____
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2278 ft2
0 ft2 Light
N
0.6 No 0.9
No
20
22.62
ATTIC
RBS IRCC
V # Type
Ventilation
Vent Ratio (1 in)
Area
1 Full attic
Unvented
0
2103 ft2
N N
2/23/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) Master Bedroom
0
Blown
316 ft2
0.1
Wood
2
Under Attic (Unvented) Master Bath
0
Blown
212 ft2
0.1
Wood
3
Under Attic (Unvented) Office
0
Blown
132 ft2
0.1
Wood
4
Under Attic (Unvented) Foyer
0
Blown
66 ft2
0.1
Wood
5
Under Attic (Unvented) Laundry
0
Blown
84 ft2
0.1
Wood
6
Under Attic (Unvented) Pantry
0
Blown
32 ft2
0.1
Wood
7
Under Attic (Unvented) Hall 1
0
Blown
16 ft2
0.1
Wood
8
Under Attic (Unvented) Hall 2
0
Blown
16 ft2
0.1
Wood
9
Under Attic (Unvented) Bedroom 2
0
Blown
165 ft2
0.1
Wood
10
Under Attic (Unvented) Bath
0
Blown
60 ft2
0.1
Wood
11
Under Attic (Unvented) Bedroom 1
0
Blown
221 ft2
0.1
Wood
12
Under Attic (Unvented) Dining
0
Blown
170 ft2
0.1
Wood
13
Under Attic (Unvented) Family Room
0
Blown
272 ft2
0.1
Wood
14
Under Attic (Unvented) Kitchen
0
Blown
303 ft2
0.1
Wood
15
Under Attic (Unvented) AHU
0
Blown
8 ft2
0.1
Wood
16
Under Attic (Unvented) Hall 3
0
Blown
30 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Belo w
Space
1
N
Exterior Concrete Block - Int InsMaster Bedro
4.1
16
0 9
5
150.7 ft2
0
0
0.5
0
2
E
Exterior Concrete Block - Int InsMaster Bedro
4.1
8
0 9
5
75.3 ft2
0
0
0.5
0
3
S
Exterior Concrete Block - Int InsMaster Bedro
4.1
1
0 9
5
9.4 ft2
0
0
0.5
0
4
W
Exterior Concrete Block - Int InsMaster Bedro
4.1
21
0 9
5
197.8 ft2
0
0
0.5
0
5
E
Exterior Concrete Block - Int InstHllaster Bath
4.1
3
0 9
5
28.3 ft2
0
0
0.5
0
6
S
Exterior Concrete Block - Int InsWaster Bath
4.1
12
0 9
5
113.0 ft2
0
0
0.5
0
7
W
Exterior Concrete Block - Int Instlillaster Bath
4.1
18
0 9
5
169.5 11:2
0
0
0.5
0
8
S
Exterior Concrete Block - Int Insul Office .
4.1
12
0 9
5
113.0 ft2
0
0
0.5
0
9
S
Exterior Concrete Block - Int Insul Foyer
4.1
6
0 9
5
56.5 ft2
0
0
0.5
0
_ 10
S
Exterior Concrete Block - Int Insul Laundry
4.1
12
0 9
5
113.0 ft2
0
0
0.5
0
11
E
Exterior Concrete Block - Int InsuBedroom 2
4.1
11
0 9
5
103.6 ft2
0
0
0.5
0
12
E
Exterior Concrete Block - Int Insul Bath
4.1
6
0 9
5
56.5 ft2
0
0
0.5
0
13
N
Exterior Concrete Block- Int InsuBedroom 1
4.1
15
0 9
5
141.3 ft2
0
0
0.5
0
14
E
Exterior Concrete Block - Int InsuBedroom 1
4.1
15
0 9
5
141.3 ft2
0
0
0.5
0
_ 15
N
Exterior Concrete Block - Int Insul Dining
4.1
12
0 9
5
113.0 ft2
0
0
0.5
0
16
W
Exterior Concrete Block - Int Insul Dining
4.1
12
0 9
5
113.0 ft2
0
0
0.5
0
_ 17
N
Exterior Concrete Block - Int Ins6hmily Room
4.1
16
0 9
5
150.7 ft2
0
0
0.5
0
_ 18
NW
Exterior Concrete Block - Int Insul Kitchen
4.1
5
10 9
5
54.9 ft2
0
0
0.5
0
19
S
Exterior Frame - Wood Bedroom 2
11
15
9
4
140.0 ft2
0.23
0.5
0
20
S
Exterior Frame - Wood Kitchen
11
6
9
4
56.0 ft2
0.23
0.5
0
_21
E
Exterior Frame - Wood Hall 1
11
4
9
4
37.3 ft2
0.23
0.5
0
_22
E
Exterior Frame - Wood Laundry
11
7
9
4
65.3 ft2
0.23
0.5
0
2/23/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated
Kitchen
None
.39
3
6 8
20 1`1:2
WINDOWS
Orientation shown is the entered Proposed orientation.
/
Wall
Overhang
V #
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Metal
Low-E Single
Yes
0.65 0.3
Y
61.5 ft2
10 ft 0 in
1 ft4 in
None
None
2
W
4
Metal
Low-E Single
Yes
0.65 0.3
Y
30.0 ft2
1 ft 5 in
1 ft 4 in
None
None
3
S
6
Metal
Low-E Single
Yes
0.65 0.3
Y
12.0 ft2
1 ft 5 in
1 ft 4 in
None
None
4
W
7
Metal
Low-E Single
Yes
0.65 0.3
Y
6.0 ft2
1 ft 5 in
1 ft 4 in
None
None
5
S
8
Metal
Low-E Single
Yes
0.65 0.3
Y
12.0 ft2
1 ft 5 in
1 ft 4 in
None
None
6
S
9
Metal
Low-E Single
Yes
0.65 0.3
Y
24.0 ft2
4 ft 0 in
1 ft 4 in
None
None
7
S
9
Metal
Low-E Single
Yes
0.65 0.3
Y
16.0 ft2
4 ft 0 in
1 ft4 in
None
None
8
S
10
Metal
Low-E Single
Yes
0.65 0.3
Y
10.0 ft2
1 ft5 in
1 ft4 in
None
None
9
E
11
Metal
Low-E Single
Yes
0.65 0.3
Y
15.0 ft2
1 ft5 in
1 ft4 in
None
None
10
E
12
Metal
Low-E Single
Yes
0.65 0.3
Y
6.0 ft2
1 ft 5 in
1 ft4 in
None
None
11
N
13
Metal
Low-E Single
Yes
0.65 0.3
Y
15.0 ft2
1 ft5 in
1 ft4 in
None
None
12
N
15
Metal
Low-E Single
Yes
0.65 0.3
Y
30.0 ft2
1 ft5 in
1 ft 4 in
None
None
13
W
16
Metal
Low-E Single
Yes
0.65 0.3
Y
15.0 ft2
4 ft 0 in
1 ft 4 in
None
None
14
N
17
Metal
Low-E Single
Yes
0.65 0.3
Y
82.0 ft2
16 ft 0 in
1 ft 4 in
None
None
15
NW
18
Metal
Low-E Single
Yes
0.65 0.3
Y
20.5 ft2
14 ft 0 in
1 ft 4 in
None
None
16
NW
18
Metal
Low-E Single
Yes
0.65 0.3
Y
8.5 ft2
14 ft 0 in
1 ft 4 in
None
None
17
NW
18
Metal
Low-E Single
Yes
0.65 0.3
Y
9.1 ft2
14 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
420 ft2
420 ft2
-32 It
9.4 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgIA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50)
.000358
1976.8 108.45
203.61
.1155
6
HEATING SYSTEM
#
System Type
Subtype
Speed
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
27 kBtu/hr
1
sys#1
2/23/2021 5:15 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
36 kBtu/hr
cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
--- Supply ---
--- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 80 ft2
Attic
20 ft2 Prop. Leak Free
AHU
-- cfm
63.1 cfm ' 0.03
0.50
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
IdJan € F
M
�X� Mar
A pr
MayX� Jun f Jul
Aug
ri
Sep
ri
� Oct
Oct X
Nov
Nov
Dec
DecJun
Venting eb
Apr
May l[ Jul
Aug
Sep
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
66
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Office,
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 1
Default(8 lbs/sq.ft.
ft2
ft
0.3
Hall 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 1
Default(8 lbs/sq.ft.
ft2
ft
0.3
Dining
2/23/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ftz ft 0.3
Family Room
Default(8 Ibs/sq.ft.
ftz ft 0.3
Kitchen
Default(8 lbs/sq.ft.
ft2 ft 0.3
AHU
Default(8 Ibs/s .ft.
ftz ft 0.3
Hall 3
A
2/23/2021 5:15 PM 7.0.00 - FlaRes2020 FBC 7th Edition'(2020) Compliant Software Page 7 of 7
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
A
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lobo Residence Builder Name:
Street: 4704 Paleo Pines Circle Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34951 Permit Number:
Y
U
Owner: Nancy Lobo Jurisdiction: St. Lucie County
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
i
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and We shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend e and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be Installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
betwegn fire sprinkler cover plates and wallsor ceilongs.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
2/23/2021 5:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
4704 Paleo Pines Circle, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1900.60 ft2
b. Frame -Wood, Exterior
R=11.0
298.67 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0
2103.00 ft2
6. Conditioned floor area (ft2)
2103
b. N/A
R=
ft2
7. Windows** Description
Area
c. N/A
R=
2
a. U-Factor: Sgl, U=0.65
372.65 ft2
12. Ducts, location &insulation level
R ft2
a. Sup: Attic, Ret: Attic, AH: AHU
6 80
SHGC: SHGC=0.30
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
36.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
27.0
COP:1.00
Area Weighted Average Overhang Depth:
7.712 ft.
Area Weighted Average SHGC:
0.300
8. Skylights Description
Area
15. Hot water systems
Cap:
50 gallons
a. U-Factor(AVG): N/A
ft2EF:0.95
a. Electric
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2102.50 ft2
Credits (Performance method)
CF, Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code m liant features.
Builder Signature: Date: �� x
Address of New Home:G',r City/FL Zip: 14 [ ''
,3�t lSi
n
E
k
a
c
p SHE ST" 2'.
0
4- a°
4
D Wos
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2123/2021 5:15 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1