EVALUATION REPORT FLORIDA BUILDING CODE, r EDITION (2020)
Manufacturer:
Manufacturing:
Quality Assurance:
SCOPE
DREXEL METALS, INC.
1234 Gardiner Lane
Louisville, KY 40213
(502) 716-7143
www.drexmet.com
Issued August 9, 2020
Drexel Metals Association of Regional Manufacturers (DM -ARM)
Architectural Testing, Inc., An Intertek Company (QUA1844)
Category: Roofing
Subcategory: Metal Roofing
Code Edition: Florida Building Code, 71'h Edition (2020) High -Velocity Hurricane Zones (HVHZ)
Code Sections: 1518.9.1, 1523.1.1, 1523.6.5, 1523.6.5.2.4, 1523.6.5.2.4.1
Properties: Wind Resistance
REFERENCES
99&
Report No.
Standard
Year
Architectural Testing (TST1558)
56840.02-122-18
TAS 100
1995
Architectural Testing (TST1558)
56842.02-122-18
TAS 100
1995
Architectural Testing (TST1558)
58461.01-122-44
TAS 125
2003
Architectural Testing (TST1558)
58641.02-122-44
TAS 100
1995
Architectural Testing (TST1527)
H3245.01-450-18
TAS 125
2003
Architectural Testing (TST1527)
H3245.02-450-18
TAS 100
1995
Architectural Testing (TST1527)
H9058.02-450-18
TAS 125
2003
Architectural Testing (TST1527)
H9058.01.450-18
TAS 125
2003
Architectural Testing (TST1527)
H9058.03-450-18
TAS 100
1995
Hurricane Test Laboratory (TST1527)
0287-0209-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0308-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0311-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0312-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0313-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0512-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0706-07
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
VL8-005-02-01
ASTM B 117
2016
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
VLS-004-02-01
ASTM G 155
2013
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
DMC-002-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-004-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-005-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-006-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-007-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-008-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-009-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-014-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-016-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-030-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
HTL-013-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
HTL-014-02-01
TAS 100
1995
DRX15002.6 FL17679-R6 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
x: CREEK
TECHNICAL, SERVICES, LLC
PRODUCT DESCRIPTION
DREXEL METALS, INC.
Metal Roofing (HVHZ)
DMC 100NS
Profile:
1 in. snap lock seam; Max. 16 in. coverage
Description:
Non-structural, snap lock standing seam roof panel with integral perorated nail
strip
Material:
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
Is"
DMC 150SS
Profile:
1.5 in. mechanical seam; Max. 16 in. coverage
Description:
Non-structural, mechanical lock standing seam roof panel
Material:
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 16 ksi; Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fm = min. 50 ksi; Shall conform with FBC Section 1507.4.3
I � 2 9n I I
1�,fig
_T
16" I
DMC 175S
Profile:
1.75 in. snap lock seam; Max. 18 in. coverage
Description:
Non-structural, snap lock standing seam roof panel
Material:
0.032-inch (Fy = min. 24 ksi) or 0.040-inch (Fy = min. 20 ksi) Fluropon® coated
ASTM B209 aluminum; Shall conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90ASTM A792 or ASTM A653; Fy = min. 50 ksi; Shall conform with
FBC Section 1507.4.3
1e
L
18,
DRX15002.6 FL17679-R6 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL. SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
DMC 200S
Profile:
2 in. mechanical seam; Max. 16 in. coverage
Description:
Non-structural, mechanical lock standing seam roof panel
Material:
Min. 0.040 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 20 ksi; Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon®•coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
2" 2°
1
DMC 5V
Profile:
13/8 in. ribs; Min. 21 in., Max. 24 in. coverage
Description:
Non-structural, through fastened roof panel
Material:
Min. 26 ga. Fluropon® coated ASTM A792 or ASTM A653 G90 ; Fy = min. 50 ksi;
Shall conform with FBC Section 1507.4.3
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 19 ksi; Shall
conform with FBC Section 1507.4.3
— ;21"Up_to 24" Couerage,
S.
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements
for the rational design of the roof deck, including the attachment, are not within the scope of this
evaluation.
3. Roof slope shall be 2:12 or greater.
4. Reroofing shall be in accordance with Section 1521.
5. Installation of the evaluated products shall comply with this report, RAS 133, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
6. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
DRX15002.6 FL17679-R6 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
W� CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
DREXEL METALS, INC.
Metal Roofing (HVHZ)
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7"' Edition (2020) High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted
by the named manufacturer.
01111 u1till
G�PY R P,Q/�i,�.
E'0 No 74021
'.. STATE OF .' /
.-,FS,O N A;
CERTIFICATION OF INDEPENDENCE
2020.08.09
v. 15:10:24
OgittlyYW4ML Nry N'P*t ao
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A— Installation (9 pages)
2) APPENDIX B —Approved Roof Systems (5 pages)
3) APPENDIX C — Design Wind Loads(3 pages)
DRX15002.6 FL17679-R6 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK MeMETALS, INC.
Metal
w Metal Roofing (HVHZ)
TECHNICAL, SERVICES, LLC
APPENDIX A
INSTALLATION
Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a Selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component .
Product
Installation Detail
#9-15 HWH wood screw
with sealing washer
Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion
resistant in accordance with FBC section 1507.4.4.
#10-13 PH wood screw
Fasteners
#10-16.DP3 PH self -
drilling screw
Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be
#14-13 DP1 PH self-
corrosion resistant in accordance with FBC section 1507A.4.
drilling screw
Bearing Plates
18 ga. Bearing Plate
3"
® Y
24 ga. SS in -seam clip
1
24 ga. DMC 15OSS Clip
;3
8
Clips
2"
24 ga. in -seam clip
Tn
/ 16' 1.
1
24 ga. DMC 150SS Fixed
3o T 19
Clip
0
o
„ _"'
B `'4
22 ga. SS in -seam clip
�s
Clips
22 ga. DMC 150SS Clip
1 �
e- T o_
0
DRX15002.6 FL17679-R6 Page 1 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Component
Product
Installation Detail
22 ga. in -seam clip
7
22 ga. DMC 15OSS Fixed
Clip
1
301 8 T o
0
o 6k
22 ga. base; 24 ga. butterfly in -seam clip
DMC 15OSS Butterfly
Clip
*fir r
'— �`r '
1 518 r ` d
4':
22 ga. base; 24 ga. butterfly in -seam clip
Er
DMC 150SS Continuous
Butterfly Clip
i'
18 ga. in -seam clip
l� \
Clips
DMC 175S UL Clip
Li
o
DRX15002.6 FL17679-R6 Page 2 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
A�7 CREAK
TECHNICAL. SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Component
Product
Installation Detail
22 ga. SS in -seam clip
4.A
l
DMC 200S Clip"
T
A
18 ga. base; 22 ga. butterfly in -seam clip; 4.5 in. length
DMC 200S Butterfly Clip
4
lips (Cont'd)
e
18 ga. base; 22 ga. butterfly inseam clip; 120 in. length; top slider 12 in. o.c.
�a
DMC 200S Continuous
r
Butterfly Clip
f
s,
r�
Sealants
Bostik 70-05A
Shall be applied in continuous beads along the seam
Bostik Chem -Calk 915
Fastening Details
Nomenclature
Attachment
DMC 1L 0NS PANE.
1 — 13 Prlw
DMC 100NS Standard
DRX15002.6
FL17679-R6
3of9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL, SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature
Attachment
� ] GION&P A LHW
DMC 100NS Enhanced
DMC 15OSS PANEL
DMC 1508S CONTINUOUS BUTTERFLY CLIP----�
(2) #10 -13 PHW'
UNDERLAYMENT —
DMC 15OSS Continuous
SUBSTRATE
Butterfly
T
i
DMC 1508S PANEL---
DMC: 15OSS BUTTERFLY CLIP
(2)'#10 -13 PHW
UNDERLAYMENT
DMC 15OSS Butterfly
SUBSTRATE —
r
DMC 15OSS PANEL
24 GA DMC 150SS FIXED CLIP
(2) #1 D -13 PHW
UNDERLAYMENT
SUBSTRATE
DMC 15OSS Fixed - 90
1
C
DRX15002.6
FL17679-R6
4 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature
`` Attachment
DMC 15OSS PANEL
24 GA DMC150S9 CLIP
(2) #1.0 -13 PHW
UNDERLAYMENT
DMC 15OSS Standard (Al)
.SUBSTRATE
174" BEAD'BOSTIK 70=05A--�
DMC 15OSS PANEL
`22 GA DMC, 150SS''FIXED CLIP - --- ---
DMC 15OSS Fixed
(2) #10 -13 PHW - ----
Enhanced -90
UNDERLAYMENT
SUBSTRATE j
DMC 150SS PANEL
22 GA DMC 1508S FIXED CLIP
(2) #10 =13 PHW �
UNDERLAYMENT
DMC 15OSS Fixed
SUBSTRATE
Enhanced - 180
DRX15002.6 FL17679-R6 .. Page 5 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature
Attachment
1/4" BEAD BOSTIK70-05A—`
DMC 150SS PANEL-�
22 GA DMC 150SS CLIP ,�
(2).#10 -13 PHW \-
DMC 15OSS Enhanced (Al)
UNDERL"ENT
SUBSTRATE
DMC 175S Panel—\
DMC 175S UL Clip
#10-13 PH Screw—
(2)
per clip
i\
DMC 175S #10 Standard
DMC 1739 PANEL�� ,
DMC 175S UL CLIP �t •�
914 -13 DP1 PHDD (2 Per Gip)
WO-18GA13EARINGPLATE—� \
METAL DECK
ISO INSULATION'
I,
DMC 175S #14 Standard
1 -
DRX15002.6 FL17679-R6 Page 6 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature
Attachment
DMC200S PANEL
DMC'2608 BUTTERFLY CLIP
(2)'#10--13 PHW
UNDERLAYMENT
SUBSTRATE
DMC 200S Butterfly
111
DMG 200S PANEL
DMG`200S:BUTTERFLY CLIP -�
#10 .16 DP3 PHD
UNDERLAYMENT
METAL DECK
DMC 200S Butterfly (Steel)
Use 18 ga. bearing plate over polyisocyanurate insulation
DMC200S. (PANEL-\
DMC 200S CONTINOU.S
BUTTERLY CLIP�. -
#10 -- 6 DP.& PHD ---,`.
UNDERLAYMENT
METAL DECK `V `` -
DMC 200S Continuous
Butterfly (Steel)
Use 18 ga. bearing late over polyllsocyanurate insulation
DRX15002.6
FL17679-R6
7of9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
FzZvW
;t CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
Fastening Details
Nomenclature
Attachment
DMC 200S PANEL
DMC 200S .CLIP
(2) #10 -13 PHW
UNDERLAYMENT
SUBSTRATE
DMC 200S Fixed
8
1/4" BEAD BOSTIK 70-05A
DMC 200S PANEL
DMC 200S CLIP
(2) #10 -13 PHW
DMC 200S Fixed
Enhanced
UNDERLAYMENT
SUBSTRATE I
SEALING .WAS HER
` �#915 HWHWOOD SCREW WITH
DMC 5V Standard
DRX15002.6
FL17679-R6
8of9
This'evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Fastening Details
Nomenclature Attachment
#10 - 14 DREXMET WO.OD,SCREW
DMC 5V PANEL
METSHIELD HT UNDERLAYMENT
DMC 5V #10 Standard PLYWOOD
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX A
DRX15002.6 FL17679-R6 Page 9 of 9
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
APPROVED ROOF SYSTEMS
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
The following notes shall be observed when using the assembly tables below.
1. Maximum Design_Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1523.4.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system.
5. Underlayment shall be installed in accordance with FBC requirements. The minimum underlayment shall be ASTM D 226, Type II installed as described
in FBC Section 1518.2.1 with nails and tin caps per 1517.5.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR)
conforming to ANSI/SDI-RD1.0 & FBC. In no case shall the panels be installed on less than two continuous spans, which are spaced a maximum 5-ft o.c.
At minimum, the deck shall be attached with one (1) #12 x 1.5-inch HWH self -drilling screws at the bottom of each flute (maximum. 6-inch o.c. along the
support). At minimum, the deck side laps shall be fastened a maximum 6-inch o.c. with #12 x 1.5-inch HWH self -drilling screws.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 19/32-inch thick APA Span -Rated plywood
sheathing or wood plank at maximum 24-inch span for new construction. Existing construction shall be the minimum plywood sheathing or wood plank
thickness at maximum 24-inch span as stated in the approval tables on following pages. In no case shall the attachment be less than 8d ring shank nails
spaced 6-inch o.c.
Roof System Numbers and Definitions
100NS-W#
DMC 100NS over Wood Deck New or Existin
150SS-W#
DMC 15OSS over Wood Deck New or Existing)
175S-S#
DMC 175S over Steel Deck New or Existing)
175S-W#
DMC 175S over Wood Deck new or Existing
200S-S#
DMC 200S over Steel Deck New or Existing)
200S-W#
DMC 200S over Wood Deck New or Existing
5V-W#
DMC 5V over Wood Deck New or Existing
Approved Systems for DMC 100NS over Wood Deck (New or Existing) .
System
Deck
Fire Barrier
Underlayment
Roof Panel
Panel Attachment
MDP
No.
(psf)
100NS-W1
Min. 15/32
OPTIONAL
As required per FBC
24 ga. DMC 10ONS
DMC 100NS Standard attachment
-97.5
COX plywood
Versashield Solo
Max 16-inch wide
with fasteners spaced 10.5 in. o.c.
100NS-W2
Min. 15/32
OPTIONAL
As required per FBC
24 ga. DMC 10ONS
DMC 100NS Standard attachment
-120
COX plywood
Versashield Salo
Max 16-inch wide
with fasteners spaced 5.25 in. o.c.
100NS-W3
Min. 15/32
OPTIONAL
As required per FBC
24 ga. DMC 100NS
DMC 10ONS Enhanced attachment
-135
COX plywood
Versashield Solo
Max 16-inch wide
with fasteners spaced 5.25 in. o.c.
DRX15002.6
FL17679-R6
1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LL,C
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
Approved Systems for DMC 15OSS
over Wood Deck (New or Existing)
System
No.
Deck
Fire Barrier
Underlayment
Roof Panel
Panel Attachment'
MDP
(pso
150SS-W1
Min. 15/32
OPTIONAL
As required per FBC
0.032" AI DMC 15OSS
Max 16-inch wide
DMC 15OSS Standard (Al) attachment
-90
CDX plywood
Versashield Solo
180" seam
with clips spaced 16 in. o.c.
150SS-W2
Min.
OPTIONAL
As required per FBC
24 ga. DMC 15OSS
Max 16-inch wide
DMC 150SS Fixed - 90 attachment
-90
CDX plywood
Versashield Solo
90" seam
with clips spaced 16 in. o.c.
150SS-W3
Min. 15/32
OPTIONAL
As required per FBC
24 gDMC 15OSSa.
Max 16-inch wide
DMC 150SS Butterfly attachment
-99.25
CDX plywood
Versashield Solo-
180° seam
with clips spaced 16 in. O.C.
150SS-W4
Min. 15/32
OPTIONAL
As required per FBC
24.gDMC 15OSSa.
Max 16-inch wide
DMC 150SS Continuous Butterfly attachment
-114.25
CDX plywood
Versashield Solo
180° seam
with fasteners spaced 12 in. o.c.
150SS-W5
Min. 15/32
OPTIONAL
As required per FBC
24 gDMC 150SSa.
Max 16-inch wide
DMC 150SS Fixed Enhanced - 90 attachment
-150
CDX plywood
Versashield Solo
Min. 90' seam
with clips spaced 12 in. o.c.
150SS-W6
Min. 15/32
OPTIONAL
As required per FBC
24 ga. DMC 15OSS
Max 16-inch wide
DMC 150SS Fixed Enhanced - 180 attachment
-165
CDX plywood
Versashield Solo
Min. 180" seam
with clips spaced 8 in. o.c.
150SS-W7
Min. 15/32
OPTIONAL
As required per FBC
0.032" AI DMC 150SS
Max 16-inch wide
DMC 150SS Enhanced (Al) attachment
-180
CDX plywood
Versashield Solo
180" seam
with clips spaced 8 in. o.c.
Approved Systems for DMC 175S over Steel Deck New or Existing)
System
No.
Deck
Fire Barrier
Insulation
Underlayment
Roof Panel
Panel Attachment
MDP
(psq
175S-Si
Min. 22 ga.
As required
Min. 1 in. Approved
polyisocyanurate
As required per FBC
AI DMC
DMC 175S Standard attachment
-88
Type B Steel
insulation board
Max. wide175S
Max. 17.5-inch wide
s#14
with clips spaced 18 in, o.c.
clips
DRX15002.6
FL17679-R6
2of5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
Approved S tems for DMC 175S over Steel
Deck New or Ex
sting)
System
No.
Deck
Fire Barrier
Insulation
Underlayment
Roof Panel
Panel Attachment
MDP
(Pso
175S-S2
Min. 22 ga.
As required
Min. 1 in. Approved
polyisocyanurate
As required per FBC
0.040" AI DMC 175S
DMC 175S #14 Standard attachment
429.25
Type B Steel
insulation board
Max. 17.5-inch wide
with clips spaced 12 in. o.c.
Approved Systems for DMC 175S over WoodDeck (New or Existing)
System
No.
Deck
Fire Barrier
Underayment
Roof Panel
Panel Attachment
MDP
(Psf)
ASTM D 226, Type II roofing felt attached per
175S-W1
Min. 15/32
-
1518.2.1 with nails and tin caps per 1517.5
0.032" AI DMC 175S
DMC 175S #10 Standard attachment
74.75
CDX plywood
followed by Metshield High -Temp
Max. 18-inch wide
with clips spaced 24 in. o.c.
Underlayment self -adhered to felt
175S-W2
Min. 15/32
OPTIONAL
Versashield
As requited per FBC
24 ga. DMC 175S
DMC 175S #10 Standard attachment
-84.25
CDX plywood
Solo
Max. 18-inch wide
with clips spaced 16 in. o.c.
175S-W3
Min. 15/32
OPTIONAL
Versashield
As required per FBC
0.040" AI DMC 175S
DMC 1755 #10 Standard attachment
-106.75
CDX plywood
Solo
Max. 17.5-inch wide
with clips spaced 18 in. o.c.
175S-W4
Min. 15/32
OPTIONAL
Versashield
As required per FBC
24 ga. DMC 175S
DMC 175S #10 Standard attachment
-121.75
CDX plywood
Solo
Max. 18-inch wide
with clips spaced 8 in. o.c.
ASTM D 226, Type II roofing felt attached per
175S-W5
Min. 15/32
_
1518.2.1 with nails and tin caps per 1517.5
0.032" AI DMC 175S
DMC 175S #10 Standard attachment
431
CDX plywood
followed by Metshield High -Temp
Max. 18-inch wide
with clips spaced 6 in. o.c.
Undedayment self -adhered to felt
Approved Systems for DMC 200S over Steel Deck New or Existing
System
No.
Deck
Fire Barrier
Insulation
Underlayment
Roof Panel
Panel Attachment
MDP
(Pso
20OS-S1
Min. 22 ga.
As required
Min. 1 in. Approved
polyisocyanurate
As required per FBC
24 ga. DMC 200S
Max. 16-inch wide
DMC 200S Butterfly (Steel) attachment
-88
Type B Steel
insulation board
180" seam
with clips spaced 24 in. o.c.
DRX15002.6
FL17679-R6
3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX B
Approved Systems for DMC 200S over Steel Deck New or Ex
sting)
System
No.
Deck
fire Barrier
Insulation
Underlayment
Roof Panel
Panel Attachment
MDP
(psfl
200S-S2
Min. 22 ga.
required
None
As required per FBC
24 ga. DMC 200SAs
Max. 16-inch wide
DMC (Steel) attachment
-91.75
Type B Steel
180° seam
with lips spaced
with clips spaced 24 in. o.c.
200S-S3
Min. 22 ga.
As required
Min. 1 in. Approved
polyisocyanurate
As required per FBC
24 ga. DMC 200S
Max. 16-inch wide
DMC 200S Continuous Butterfly (Steel)
-121.75
Type B Steel
insulation board
180° seam
attachment with clips spaced 12 in. o.c.
200S-S4
Min. 22 ga.
Type B Steel
As required
None
As required per FBC
24 ga. DMC 200S
Max. 164nch"wide
DMC 200S Continuous Butterfly (Steel)
attachment with clips spaced 12 in. o.c.
-151.75
180° seam
Approved Systems for DMC
200S over Wood Deck (New or Existing)
System
No.
Deck
Fire Barrier
Underlayment
Roof Panel
Panel Attachment
MDP
(psfl
200S-W1
Min. 19/32
OPTIONAL
As required per
0Max. 1 DMC 200S
Max 1 wide
DMC 200S Fixed attachment
-105
CDX plywood
Versashield Solo
FBC
* sea
180° seam
with clips spaced 16 in. o.c.
200S-W2
Min. 19/32
OPTIONAL
As required per
0.040" AI DMC 200S
Max.16-inch wide
DMC 200S Fixed Enhanced attachment
480
CDX I
plywood
Versashield Solo
FBC
180° seam
with clips spaced 8 in. o.c.
Approved Systems for DMC 5V over Wood Deck (New or Existing)
System
No.
Deck
Fire Barrier
Underlayment
Roof Panel
Panel Attachment
MDP
(Psfl
Min. 15132
OPTIONAL
ASTM D 226, Type II roofing felt attached
per 1518.2.1 with nails and tin caps per
0.032" AI DMC 5V
DMC 5V #10 Standard attachment
5V-W1
CDX plywood
Versashield Solo
1517.5 followed by Metshield High -Temp
Min. h
with 4 HWH wood screws with
-56
Underlayment self -adhered to felt
Max 24-inch coverage
inch c e
sealing w
sealing washers spaced 18 in. o.c.
DRX15002.6
FL17679-R6
4of5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVH2)
APPENDIX B
Approved Systems for DMC 5V over Wood Deck (New or Existing)
System
No.
Deck
Fire Barrier
Undedayment
Roof Panel
Panel Attachment
MDP
(Psi
5V-W2
Min.
OPTIONAL
As required per FBC
26 ga, DMC 5V
Min. 21-inch to
DMC 5V Standard attachment
.60
CDX plywood
Versashield Solo
Max 24-inch coverage
with clips spaced 16 in. o.c.
Min.
OPTIONAL
ASTM D 226, Type II roofing felt attached
per 15follow with nails and tin caps per
26 ga. DMC 5V
DMC 5V #10 Standard attachment
5V-W3
CDX plywood
plywood
Versashield Solo
1517.5 followed Metshield High -Temp
Min. 21-inch to
with #10-14 HWH wood screws with
-71
-
t
Underiaymentseff-adhered to felt
Max 24-inch coverage
sealing washers spaced 24 in. o.c.
5V-W4
Min.
OPTIONAL
As required per FBC
26 ga, DMC 5V
Min. 214nch to
DMC 5V Standard attachment
-121.75
CDX plywood
Versashield Solo
Max 24-inch coverage
with clips spaced 8 in. o.c.
ASTM D 226, Type II roofing felt attached
26 ga. DMC 5V or
DMC 5V #10 Standard attachment
5V-W5
Min. 15/32
OPTIONAL
per 1518.2.1 with nails and tin caps per
0.032" AI DMC 5V
with #10-14 HWH wood screws with
-206
CDX plywood
Versashield Solo
1517.5 followed by Metshield High -Temp
Min. 21-inch to
sealing washers spaced 6 in. o.c.
Underlayment self -adhered to felt
Max 24-inch coverage
DRX15002.6
FL17679-R6
5of5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
ft
CREEK
TECHNICAL SERVICES, LLC
DESIGN WIND LOADS
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX C
The following tables provide design wind loads for components and cladding in accordance with Section 1620 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, Il, III, and IV buildings shall be as defined in Section 1620 of the FBC.
2. Exposure C and D shall be as defined in section 1620 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-fe or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd = 0.85
8. Design wind loads are calculated using Pasd = 0.6Put.
9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12. Zones 1, 2, and 3 shall be defined as shown below. Dimension "a" shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever
is smaller, but not less than either 4% of the least horizontal dimension or 3ft
Gable Hip
�\
X
DRX15002.6 FL17679-R6 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX C
Gable/Hip Roofs in Exposure C In Miami -Dade 8'Broward County Roof slopes between 2:12 and 12:12
Building Type
Zone
Mean Roof
Height (ft)
9 .. Wind Speed Basic W (mph)LL
. Risk Catt
_ : - Risk Cat I
Risk Cat II
Risk Cat II"r
Risk Cat III, IV- �
Risk Cat III,IV
156
", 165
170
175
180
186_
Enclosed/
Partially Open
1
20
-62.3
-69.7
-74.0
-78.5
-83.0
-88.6
25
-65.1
-72.8
-77.3
-81.9
-86.7
-92.6
30
-67.9
-75.9
-80.6
-85.4
-90.4
-96.5
40
-72.0
-80.6
-85.6
-90.7
-95.9
-102.4
50
-75.5
-84.5
-89.7
-95.0
-100.5
-107.3
60
-78.3
-87.6
-93.0
-98.5
-104.2
-111.3
2
20
-90.9
-101.7
-108.0
-114.4
-121.1
-129.3
25
-95.0
-106.3
-112.8
-119.5
-126.5
-135.0
30
-99.0
-110.8
-117.6
-124.6
-131.8
-140.8
40
-105.1
-117.6
-124.8
-132.2
-139.9
-149.4
50
-110.1
-123.2
-130.8
-138.6
-146.6
-156.6
60
-114.2
-127.7
-135.6
-143.7
-152.0
-162.3
3
20
-108.1
-120.9
-128.4
-136.0
-143.9
-153.7
25
-112.9
-126.3
-134.1
-142.1
-150.3
-160.5
30
-117.7
-131.7
-139.8
-148.1
-156.7
-167.3
40
-124.9
-139.7
-148.3
-157.2
-166.3
-177.6
50
-130.9
-146.5
-155.5
-164.7
-174.3
-186.1
60
-135.7
-151.8
-161.2
-170.8
-180.7
-192.9
Partially
Enclosed
1
20
-72.9
-81.6
-86.6
-91.8
-97.1
-103.7
25
-76.2
-85.2
-90.4
-95.8
-101.4
-108.3
30
-79.4
-88.8
-94.3
-99.9
-105.7
-112.9
40
-84.3
-94.3
-100.1
-106.0
-112.2
-119.8
50
-88.3
-98.8
-104.9
-111.1
-117.6
-125.5
60
-91.6
-102.4
-108.7
-115.2
-121.9
-130.2
2
20
-101.5
-113.6
-120.6
-127.8
-135.2
-144.3
25
-106.0
-118.6
-125.9
-133.4
-141.2
-150.7
30
-110.5
-123.7
-131.3
-139.1
-147.2
-157.1
40
-117.3
-131.2
-139.3 -
-147.6
-156.2
-166.8
50
-123.0
-137.5
-146.0
-154.7
-163.7
-174.8
60
-127.5
-142.6
-151.4
-160.4
-169.7
-181.2
3
20
-118.7
-132.8
-140.9
-149.3
-158.0
-168.7
25
-124.0
-138.7
-147.2
-156.0
-165.0
-176.2
30
-129.2
-144.6
-153.5
-162.6
-172.0
-183.7
40
-137.1
-153.4
-162.9
-172.6
-182.6
-195.0
50
-143.7
-160.8
-170.7
-180.9
-191.4
-204.3
60
-149.0
-166.7
-177.0
-187.5
-198.4
-211.8
DRX15002.6 FL17679-R6 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing (HVHZ)
APPENDIX C
Ga le/Hip Roofs in Exposure D In Miaml-Dade & Broward County Roof slopes between 2:12 and 12:12
Building Type
Zone
Mean Roof
Height.(ft)
Basic Wind Speed (mph)
Risk Cat I.
Risk Cat I
Risk Cat II
Risk Cat II
Risk Cat III, IV'
Risk Cat III,IV
156
165
170 -
175
180
186 -
Enclosed/
Partially Open
1
20
-74.8
-83.7
-88.8
-94.1
-99.6
-106.3
25
-77.6
-86.8
-92.1
-97.6
-103.3
-110.3
30
-80.4
-89.9
-95.4
-101.1
-107.0
-114.2
40
-84.5
-94.5
-100.4
-106.3
-112.5
-120.1
50
-88.0
-98.4
-104.5
-110.7
-117.1
-125.1
60
-90.7
-101.5
-107.8
-114.2
-120.8
-129.0
2
20
-109.1
-122.1
-129.6
-137.3
-145.3
-155.1
25
-113.2
-126.6
-134.4
-142.4
-150.7
-160.9
30
-117.2
-131.1
-139.2
-147.5
-156.0
-166.6
40
-123.3
-137.9
-146.4
-155.1
-164.1
-175.2
50
-128.3
-143.6
-152.4
-161.5
-170.8
-182.4
60
-132.4
-148.1
-157.2
-166.6
-176.2
-188.2
3
20
-129.7
-145.1
-154.0
-163.2
-172.7
-184.4
25
-134.5
-150.5
-159.7
-169.3
-179.1
-191.2
30
-139.3
-155.9
-165.4
-175.3
-185.5
-198.1
40
-146.5
-163.9
-174.0
-184.4
-195.1
-208.3
50
-152.5
-170.6
-181.1
-192.0
-203.1
-216.8
60
-157.3
-176.0
-186.8
-198.0
-209.5
-223.7
Partially
Enclosed
1
20
-87.5
-97.9
-103.9
-110.1
-116.5
-124.4
25
-90.7
-101.5
-107.8
-114.2
-120.8
-129.0
30
-94.0
-105.1
-111.6
-118.3
-125.1
-133.6
40
-98.8
-110.6
-117.4
-124.4
-131.6
-140.5
50
-102.9
-115.1
-122.2
-129.5
-137.0
-146.3
60
-106.1
-118.7
-126.0
-133.6
-141.3
-150.9
2
20
-121.8
-136.3
-144.7
-153.3
-162.2
-173.2
25
-126.3
-141.3
-150.0
-159.0
-168.2
-179.6
30
-130.8
-146.4
-155.4
-164.7
-174.2
-186.0
40
-137.6
-154.0
-163.4
-173.2
-183.2
-195.6
50
-143.3
-160.3
-170.1
-180.3
-190.7
-203.6
60
-147.8
-165.3
-175.5
-186.0
-196.7
-210.1
3
20
-142.4
-159.3
-169.1
-179.2
-189.6
-202.5
25
-147.7
-165.2
-175.4
-185.8
-196.6
-210.0
30
-153.0
-171.1
-181.6
-192.5
-203.6
-217.4
40
-160.9
-180.0
-191.0
-202.4
-214.2
-228.7
50
-167.5
-187.3
-198.9
-210.7
-223.0
-238.1
60
-172.7
-193.2
-205.1
-217.4
-230.0
-245.6
DRX15002.6
FL17679-R6
3of3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.