HomeMy WebLinkAboutProduct Approval; Roofing UnderlaymentsXP
a
t �'° Product Approval
a '^USER: Public User
Product Aoproval Menu > Product or Anolication Search > Application List > Application Detail
FL #
FL5259-R33
Application Type
Revision
Code Version
2020
Application Status
Validated
Comments
Archived C
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
ma[pert@polyglass.com
Authorized Signature Maury Alpert
ma[pert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email lilt West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888) 410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
O Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/23/2023
Validated By John W. Knezevich, PE
0 Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R33 COI 2021 01 COI NIEMINEN.pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
hftps://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOliploQ53LIfLDSdir7nKflW%2bQ%3d%3d 1/2
4/13/2021
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Summary of Pr•ndllrte
FM 4474
2011
FRSA/TRI, Sixth Edition
2018
TAS 103
2020
UL1897
2015
Method 1 Option D
04/07/2021
04/12/2021
FL #
Model, Number or Name
Description
5259.1
Polyglass Roof Underlayments
Polyglass roof underlayments for use in FBC HVHZ jurisdictions.
(HVHZ)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 V Z �pdf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use.
Evaluation Reports
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 HVHZ .pdf
Created by Independent Third Party: Yes
5259.2
Polyglass Roof Underlayments
Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions.
(non-HVHZ)
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 NON-HVHZ1_pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
relates to one particular underlayment system for
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 NON-HVHZ).pdf
use in the roof systems. Refer to ER Section 5.8.3
for other systems and associated maximum design
Created by Independent Third Party: Yes
pressures. 2.) Refer to ER Section 5 for other limits
of use.
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuildinq.orq/pr/pr app dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2feg01iploQ53LIfLDSdir7nKfKN%2bQ%3d%3d 2/2