HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door Assemblies4/13/2021 I Florida Building Cody"Online • ���`,�� � �'" ��'� � �� a '*�yd�>� 9���w�" ,ia4� �s �, � � " - '"' � s-•"a q�+g�= n � 1 BCIS Home ( Login User Registration Hot Topics Submit Surcharge Stats & Facts ( Publications Contact Us BCIS Site Map j Links ( Search ONIM.-Ap ,Product Approval USER: Public User e& Product Approval Menu > Product or Application Search > Application List > Application Detall FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL17184-R8 Revision 2020 Approved N Plastpro Inc. / Nanya Plastics Corp. 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440) 969-9773 Ext16 rickw@rwbldgconsultants.com Vivian Wright rickw@rwbidgconsultants.com Scott Johnson 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext18 scottjohnson@plastproinc.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King; P.E. 10 Validation Checklist - Hardcopy Received Certificate of Independence FL17184 R8 COI (e) Certificate of Independence, pdf Referenced Standard and Year (of Standard) Standard Year - AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E1886 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E1996 2006 ASTM E1996 2005 ASTM E330 2002 ASTM E331 2000 TAS 201, 202, 203 1994 hfps://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvCo3EapillBW4u90%2bpvEjL3sPPpp/p2fPOTtbMp/`2fhlzP5GXxA*/o3d*/o3d 1/5 4/13/2021 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Florida Licensed Professional Engineer or Architect FL17184 R8 Eguiv of Standards 1b),pdf Product Approval Method Method 1 Option D Date Submitted 07/21/2020 Date Validated 08/12/2020 Date Pending FBC Approval 08/22/2020 Date Approved 10/13/2020 Summary of Products Go to Page tiiv Page 1 / 2 FL # Model, Number or Name Description 17184.1 a. Fiberglass Door "Impact" Fiberglass Glazed Single Door with or without Sidelite(s) (X, OX or XO, OXO) Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use In HVHZ: No FL17184 R8 II c) Inst 17184.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.1 for any additional use limitations, FL17184 118 AE c) Eval 17184.1.pdf Installation instructions and product particulars. Created by Independent Third Party: Yes 17184.2 b. Fiberglass Door "Impact" Fiberglass Glazed Double Door with or without Sidelites (XX or OXXO) Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use In HVHZ: No FL17184 R8 II 1c) Inst 17184.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.2 for any additional use limitations, FL17184 R8 AE lc) Eval 17184.2.pdf Installation instructions and product particulars. Created by Independent Third Party: Yes 17184.3 c. Fiberglass Door "Non -Impact" Fiberglass Glazed Single Door with or without Sidelite(s) (X, OX or XO, OXO) Outswing/Inswing Configurations up to Nominal 8'0 In Height Limits of Use - Installation Instructions Approved for use in HVHZ: No FL17184 R8 II 1c) Inst 17184.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.3 for any additional use limitations, FL17184 R8 AE 1c) Eval 17184.3.pdf installation instructions and product particulars. Created by Independent Third Party: Yes 17184.4 d. Fiberglass Door "Non -Impact" Fiberglass Glazed Double Door with or without Sidelites (XX or OXXO) Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R8 II (c Inst 17184.4.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.4 for any additional use limitations, FL17184 R8 AE (c) Eval 17184.4.pddf Installation Instructions and product particulars. Created by Independent Third Party: Yes 17184.5 e. Fiberglass Door "Impact" Fiberglass Opaque Single Door with or without Sidelite(s) (X, OX or XO, OXO) Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use In HVHZ: No FL17184 R8 II lc) Inst 17184.5.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvCo3EapillBW4u90%2bpvEjL3sPPp%2fPOTtbM%2fhlzP5GXxA%3d%3d 2/5 4/13/2021 Florida Building Code Online Other: See INST 17184.5 for any additional use limitations, FL17184 R8 AE (c) Eval 17184.5.pdf Installation instructions and product particulars. Created by Independent Third Party: Yes 17184.6 f. Fiberglass Door "Impact" Fiberglass Opaque Double Door with or without Sidelites (XX or OXXO) Outswing/Inswing Configurations up to Nominal 6'8 In Height Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R8 II e) Inst 17184.6.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.6 for any additional use limitations, FL17184 R8 AE e) Eval 17184.6.odf Installation instructions and product particulars. Created by Independent Third Party: Yes 17184.7 g. Fiberglass Door "Impact" Fiberglass Opaque Single Door with or without Sidelite(s) (X, OX or XO, OXO) Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R8 II (e) Inst 17184.7.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.7 for any additional use limitations, FL17184 R8 AE fe Eval 17184.7.pdf installation instructions and product particulars. Created by Independent Third Party: Yes 17184.8 h. Fiberglass Door "Impact" Fiberglass Opaque Double Door with or without Sidelites (XX or OXXO) Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use In HVHZ: No FL17184 R8 II le) Inst 17184.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.8 for any additional use limitations, FL17184 R8 AE (eJ Eval 17184.8.odf Installation instructions and product particulars. Created by Independent Third Party: Yes 17184.9 i. Fiberglass Door "Impact" Fiberglass Glazed Single Door with or without Sidelite(s) (X, OX or XO, OXO) Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R8 II (e Inst 17184.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.9 for any additional use limitations, FL17184 R8 AE (e Eval 17184.9.odf Installation instructions and product particulars. Created by Independent Third Party: Yes 17184.10 j. Fiberglass Door "Impact" Fiberglass Glazed Double Door with or without Sidelites (XX or OXXO) Outswing/Inswing Configurations up to Nominal 6'8 In Height Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R8 II le) Inst 17184.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.10 for any additional use limitations, FL17184 R8 AE le) Eval 17184.10.pdf installation instructions and product particulars. Created by Independent Third Party: Yes 17184.11 k. Fiberglass Door "Non -Impact" Fiberglass Glazed Single Door with or without Sidelite(s) (X, OX or XO, OXO) Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R8 II e) Inst 17184.11.ndf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.11 for any additional use limitations, FL17184 R8 AE le) Eval 17184.11.pdf Installation instructions and product particulars. Created by Independent Third Party: Yes 17184.12 I. Fiberglass Door "Non -Impact" Fiberglass Glazed Double Door with or without Sidelites (XX or OXXO) Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use In HVHZ: No FL17184 R8 II (e) Inst 17184.12.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports https://www.floddabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvCo3Eapi[IBW4u90%2bpvEjL3sPPp%2fPOTtbM%2fhlzP5G) xA%3d%3d 3/5