HomeMy WebLinkAboutTrussc 3'-8" 36'-4" N r ram. ti r. •,n � Cl) 04 2 Z223MA�, i J25A § LO > 14'-9" 7" V1B V2B Z' a s O a < a N a M a co a 7 a a a a a —2L 2 2- 2' 2+ 2 2' ; 2' 2' 2' 2' I I I� 0 1/411 = 11_01f L,. J21 J23 Zi I J25 J17 J17 J17 J17 J17 v (L N J17 M 4 a a a J17 -2' 2' 2 2' 2' 2' 2' 7' J17 J7 J17 J17 _ J17 J17 a I 0 4'-4" 2x4 WOOD BEARING WALL > > > C1 y 1 N Ct TYPICAL END DETAIL 12 4 1/16" HEEL HT. g -4 16" OVERHANG BEARING LLEVATIONS 9'-4" T.O.B. �U LDING COMPONENTS RM BUILDING COMPONENTS S I M PSON Strong -Tie WALL & CLG. HEIGHTS A.F.F. OF MAIN, HOUSE TRUSSES@RMBCLLC.COM DO NOT SET TRUSSES USING THIS LAYOUT USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES SIMPSON HANGERS EVISION QTY TYPE CARRYING MEMBER CARRIED MEMBER ATE DESCRIPTION LUS24 4-10d 2-10d 2 HUS26 14-16d 6-16d HGUS26 20-16d 8-16d HHUS26-2 14-16d 6-16d 1 HGUS26-2 20-16d 8-16d HUS28 22-16d 8-16d HHUS28-2 22-16d 8-11 HGUS28-2 36-16d 12-16d HGUS28-3 36-16d 12-16d THAC422 22-16d 6-16d LUS410 8-16d 6-16d REFERENCE HUS46 4-16d 4-16d HUS48 6-16d 6-16d LTHJA26 20-10d "IP `-10d ACK = 4- dx ' I *Attach hangers to 1—ply girders w/ 1 1 /2" 10d nails. eAttach hangers to 2—ply girders O A R I N G w/ 16d nails. TC LL 20_PSF *Truss manufacturer supplies hangers TC IL 16 PSF for truss to truss connections. 8 *All hangers connecting trusses to BC DIL 10, PSF building structure are determined by BC LL TYPICAL 10 PSF ATTIW/O STORAGE building designer and supplied by builder. F DC LL A NOTED 20 _PSF A WARNING NTED T A BC LL AS T D 40 PSF ATT IV SPAC Do not lift single trusses with spans greater than 30' 1 DURATION 1,25 - by the peak. Do not attach cables, chains or hooks to the web members. Refer to SCSI 1-03 Summary DEFL, TOTAL , L/240 Sheet provided for proper handling, installing and WIND SPEED 170 'MPH bracing methods. i 020 FLORIDA BIJIILDIN9 CODE ATTENTION FRAMERS/CONTRACTOR SCE 7-16, CAT, II,Enctosed Trusses are not to be cut or altered for any reason. XPOSURE C If there is a' problem, you must follow the procedures listed below: hEAN HEIGHT 15'-0' (1) Notify RMBC immediately. TC LL XX PSF (2) Secure proper Engr rgr'd for any repair. TC DL XX PSF RM BUILDING COMPONENTS will not honor any bockchorges unless authorized by a RMBC Representative. BC DL XX PSF *Roof trusses are not designed for additional attic O TOTAL LOAD XX; PSF storage loads, unless noted otherwise. DURATION1.010 *Attic frame trusses noted as storage/mechanical DEFL, TOTAL L/';360 rooms are designed with additional 30 PSF BC ILL. 8� eAttic frame trusses noted as attic living space 5 fl ? are designed with additional 40 PSF BC LL. SHEETI O F go *MULTIPLE PLY TRUSSES MUST BE FASTENED TOGETHER PER o_,o. .... D ¢¢ $$ ENGINEERING.. BEFORE THEY ARE SET. W a 1AYOUT TECH: RM V'S oWARNING! Inadequate size and/or fastening of bracing ENGR TECH: RM 81 c 8 rr material is a major cause or erection dominoing. FILENAME:' ° is p.oAny party who cuts or damages a truss'sholl be 00676.dwa responsible for securing the engineenn�.,regfi�{[ed for the repair and f tl u _ " u *For proper installatio o {�S5 o m' refer to hanger insyd� �S g W > *This truss placem�.fii"d,a9f rgRUn{ii`i(e g ® lit!-Ht [►{'s"" �" a g o e mN fabricator, general$�ntr erec ion a5 u t m �3 8 contractor. It is not intended IRubstitute for �a y a framing plan, which is the responsibility of the � ai x F, architect or engineer of record to provide. iJ a ❑ $'� v c *Trusses are designed in accordance with the ANSI/TPI 1-2014 National Design Standard) for metal plate connected wood truss construction. Refer to BCSI 1-03 Summary Sheet for bracing a� & truss design dwgs for additional permanent bracing. CD *FIELD BRACING is not the responsibility of the truss fabricator, truss designer, nor plate manufacturer. *Persons erecting trusses are cautioned to seek a) professional advice regarding erection bracing which 11 is always required to prevent toppling and dominoing. elt is the responsibility of the I" adequate access roads into a ou`� site a) 0for the safe delivery of trusses. `�� w C *WARNING! The consequences of improper handling, � � erecting, and bracing may be collapse of the w a structure, or, worse, serious personal injury, or death. I J(D IMPORTANT, O / 4/ Approval of this truss placement is necessary � p pbefore production can begin. Verify all dimensions, —1 __J O spans, pitches, overhangs, elevations, and bearing conditions. Acceptance of this truss placement W assumes total responsibility. The trusses will be - LEFT SIDE OF TRUSS built in strict accordance with this placement. O LLJ Nmo SIGNED U CD I DATE I Simpson Strong -Tie Company, Inc. To nk COMPONENT DESIGN DRAWINGS & DETAILS 5956 W. Las Positas Blvd_ Pleasanton, CA 94588 .® (800) 999-5099 www.strongtie.com RM Building Components 00676 - Lobo - Paleo Pine Circle 3/8/2021 10:50 AM 122969 Notes: 1. The component design drawings referenced below have been prepared based on design criteria and requirements set forth in the Construction Documents, as communicated by the Component Manufacturer. 2. The engineer's signature on these drawings indicates professional engineering responsibility solely for the individual components to be able to resist the design loads indicated, utilizing all the design parameter and materials indicated or referenced on each individual design. 3. It is the Building Designer's responsibility to review the component design drawings to insure compatibility with the Building design, Refer to all notes on the individual component design drawings. 54 Component Design Drawing(s): 1-A1: SID 940899 15-A15: SID 940913 29-Di: SID 940927 43-J17: SID 940941 2-A2: SID 940900 16-A16: SID 940914 30-El: SID 940928 44-J17A: SID 940942 3-A3: SID 940901 17-A17: SID 940915 31-E2: SID 940929 45-J17B: SID 940943 4-A4: SID 940902 18-A18: SID 940916 32-E3: SID 940930 46-J13: SID 940944 5-A5: SID 940903 19-A19: SID 940917 33-VlA: SID 940931 47-J25A: SID 940945 6-A6: SID 940904 20-A20: SID 940918 34-V1 B: SID 940932 48-J25: SID 940946 7-A7: SID 940905 21-A21: SID 940919 35-V1 E: SID 940933 49-J23A: SID 940947 8-A8: SID 940906 22-A22: SID 940920 36-V2A: SID 940934 50-J23: SID 940948 9-A9: SID 940907 23-Bi: SID 940921 374213: SID 940935 51-J21: SID 940949 10-A10: SID 940908 24-B2: SID 940922 38-V2E: SID 940936 52-J3: SID 940950 11-A11: SID 940909 25-C1: SID 940923 39-V3A: SID 940937 53-J3A: SID 940951 12-Al2:'SID'940910 26-C2: SID 940924 40-V4A: SID 940938 54-J3D: SID 940952 13-A13: SID 940911 27-C3: SID 940925 41-V5A: SID 940939 14-A14: SID 940912 28-C4: SID 940926 42-V6A: SID 940940 Component SolutionsTM Important Information & General Notes General Notes 1. Each Truss Design Drawing (TDD) provided with this sheet has been prepared in conformance with ANSI/TPI 1. Refer to ANSI/TPI 1 Chapter 2 for the ' responsibilities of all parties involved, which include but are not limited to the .responsibilities listed on this sheet, and for the definitions of all capitalized terms referenced in this document. 2. TDDs should not be assumed to be to scale. 3. The Contractor and Building Designer shall review and approve the Truss Submittal Package. ' 4. The suitability and use of the component depicted on the TDD for any particular building design is the responsibility of the Building Designer. 5. The Building Designer is responsible for the anchorage of the truss at all bearing locations as required to resist uplift, gravity and lateral loads, and for all Truss -to -Structural Element connections except Truss -to -Truss connections. 6. The Building Designer shall ensure that the supporting structure can accommodate the vertical and/or horizontal truss deflections. 7. Unless specifically stated otherwise, each Design assumes trusses will be adequately protected from the environment and will not be used in corrosive environments unless protected using an approved method. This includes not being used in locations where the sustained temperature is greater than 150°F. 8. Trusses are designed to carry loads within their plane. Any out -of - plane loads must be resisted by the Permanent Building Stability Bracing. 9. Design dead loads must account for all materials, including self -weight. The TDD notes will indicate the min. pitch above which the dead loads are, automatically increased for pitch effects. 10. Trusses installed with roof slopes less than 0.25/12 may experience (but are not designed for) ponding. The Building Designer must ensure that adequate drainage is provided to prevent ponding. 11. Camber is a non-structural consideration and is the responsibility of truss fabricator. Handling, Installing, Restraint & Bracing 1. The Contractor is responsible for the proper handling, erection, restraint and bracing of the Trusses. In lieu of job -specific details, refer to BCSI. 2. ANSI/TPI 1 stipulates that for trusses spanning 60' or greater, the Owner shall contract with any Registered Design Professional for the design and inspection of the temporary and permanent truss restraint and bracing. Simpson Strong -Tie is not responsible for providing these services. 3. Trusses require permanent lateral restraint to be applied to chords and certain web members (when indicated) at the locations or intervals indicated on the TDD. Web restraints are to be located at mid points, or third points of the member and chord purlins are not to exceed the spacing specified by the TDD. Chords shown without bracing indicated are assumed to be continuously braced by sheathing or drywall. Permanent lateral restraint shall be accomplished in accordance with: standard industry lateral restraint/bracing details in BCSI-133 or BCSI-B7, supplemental bracing details referenced on the TDD, or as specified in a project -specific truss permanent bracing plan provided by the Building Designer. 4. Additional building stability permanent bracing shall be installed as specified in the Construction Documents. 5. Special end wall bracing design considerations may be required if a flat gable end frame is used with adjacent trusses that have sloped bottom chords (see BCSI-133). 6. Do not cut, drill, trim, or otherwise alter truss members or plates without prior written approval of an engineer, unless specifically noted on the TDD. 7. Piggyback assemblies shall be braced as per BCSI-133 unless otherwise specified in the Construction Documents. 8. For floor trusses, when specified, Strongbacking shall be installed per BCSI-B7 unless otherwise specified in the Construction Documents. 4 Referenced Standards ANSI/TPI 1: National Design Standard for Metal Plate Connected Wood Truss Construction, a Truss Plate Institute publication (www.tpinst.org). BCSI: Guide to Good Practice for Handling, Installing, Restraining & Bracing Metal Plate Connected Wood Trusses, a joint publication of the Truss Plate Institute (www.tpinst.org ) and the Structural Building Components Association (www.sbcindustry.com ). Symbols and Nomenclature 5X7 Plate size; the first digit is the plate width (perp. to the slots) and the second digit is the plate length (parallel to the slots). 5X7-18 -18, -1855, or -1856 following the plate size indicates different 18 gauge plate types. These symbols following the plate size indicate the direction of 11. Q the plate length (and tooth slots) for square and nearly square plates. 10-3-14 Dimensions are shown in feet -inches -sixteenths (for this example, the dimension is 10'-3 14/16"). Joints are numbered left to right, first along the top chord and Z then along the bottom chord. Mid -panel splice joint numbers are not shown on the drawing. Members are identified using their end joint numbers (e.g., TC 2-3). \ When this symbol is shown, permanent lateral restraint is required. Lateral restraint may be applied to either edge of the member. See Note 3 under Handling, Installing, Restraint & Bracing for more information. Bearing supports (wall, beam, etc.), locations at which the truss is required to have full bearing. Minimum required bearing width for the given reactions are reported on the TDD. Required bearing widths are based on the truss material and indicated PSI of the support material. The Building Designer is responsible for verifying that the capacity of the support material exceeds the indicated PSI, and for all other bearing design considerations. Truss -to -Truss or Truss -to -Structural Element connection, N/ which require a hanger or other structural connection (e.g., t5toe-nail) that has adequate capacity to resist the maximum reactions specified in the Reaction Summary. Structural (�� connection type is not limited by type shown on TDD. Toe- i'� nails may be used where hanger type shown where allowed by detail or other connection design information. Design of the Structural Element and the connection of the Truss to a Structural Element is by others. Note: These symbols are for graphical interpretation only; they are not intended to give any indication of the geometry requirements of the actual item that is represented. Materials and Fabrication 1. Design assumes truss is manufactured in accordance with the TDD and the quality criteria in ANSI/TPI 1 Chapter 3, unless more restrictive criteria are part of the contract specifications. 2. Unless specifically stated, lumber shall not exceed 19% moisture content at time of fabrication or in service. 3. Design is not applicable for use with fire retardant, preservative treated or green lumber unless specifically stated on the TDD. 4. Plate type, size, orientation and location indicated are based on the specified design parameters. Larger plate sizes may be substituted in accordance with ANSI/TPI, Section 3.6.3. Plates shall be embedded within ANSI/TPI 1 tolerances on both faces of the truss at each joint, unless noted otherwise. 5. Truss plates shall be centered on the joint unless otherwise specified. DSB-89 Recommended Design Specification for Temporary Bracing of Metal Plate Connected Wood Trusses, a Truss Plate Institute publication (www.tpinst.org ). NDS: National Design Specification for Wood Construction published by American Forest & Paper Association and American Wood Council. ESR-2762 Simpson Strong -Tie® AS Truss Plates are covered under ESR-2762 published by the International Code Council Evaluation Service (www.icc-es.org ). TD-GEN-0003A 512019 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: Al Customer: Lu Dial SID: 0000940899 TID: 122969 Date: 03 109 121 Truss Mfr. Contact: Rick Mills Page: 1 of 2 s` 1 2-P1Y 4-6-11 4-6-11 4-6-11 4-6-i1 4-6-11 4-6-11 1-7-0 3-4-0 2-2-0 4-6-11 9-1-5 13-8-0 18-2-11 Al 27-4-0 8-i1- 32-3-0 34-5-0 1 2 3 4 5 6 7 8 9 10 11 170# 170# 170# 170# 170# 170# 170# 170# 170# 170# -5/12 - b 1 # # 1 # b b b b b � 1 # 4g# 4$# 71$# 4x8 b 3x8 b b 3x4= 4x6 3x4= 2x4 3x4 5x7 Sx5 = 4x8 -5/12 I M I At � N I � N UJ X 7x8ii 4x6 3x4= 4x6 7x8= 4x4= 3x4= 3x8 4x8 3x6 b b b b b b b b b b b b b b b b b 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 223# 223# 186# 4-6-11 4-6-11 4-6-11 4-6-11 4-6-11 4-6-11 1-7-0 3-4-0 2-2-0 4-6-11 9-1-5 13-8-0 18-2-11 22-9-5 27-4-0 8-11- 32-3-0 34-5-0 12 13 14 15 16 17 18 19 20 21 22 34-5-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 P1t 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load:- No Spacing: 2-00-00 O.C. Plies: 2 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = No R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary ...Mem... Ten comp CSI. Deflection Summary TC 2x4 SP (ALSC6-2013) #2 10-21 753 1195 0.06 TrussSpan Limit Actual(in) Location 2x6 SP (ALSC6-2013) #2 1-4 11-21 3673 2203 0.41 Vert LL L/360 L/999(-0.34) 15-16 9-0 11-22 2229 3668 0.19 Vert DL L/120 L/999(-0.35) 16-18 BC 2x6 SP (ALSC6-2013) #2 Reaction Summary Vert CR L/240 L/593(-0.69) 16-18 2x6 SP (ALSC6-2013) #1 17-22 --------------Reaction Summary(Lbs)---------------- Horz LL 0.75in ( 0.05) @Jt22 Webs 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Horz CR 1.25in ( 0.10) @Jt22 2x8 SP (ALSC6-2013) #2 12-1 12 03-10 3561 2138 08-00 02-13 SPF 425 Other 2x4 SP (ALSC6-2013) #2 22 34-03-04 3499 2096 01-08 HGR SPF 565 Vert CR and Horz CR are the vertical and Max Horiz = -83 / +0 at Joint 12 horizontal deflections due to live load Member Forces Summary plus the creep component of deflection ...Mem... Ten comp .CSI. Loads Summary due to dead load, computed as Defl_LL + TC OH- 1 0 0 0.00 (Kcr - 1) x Defl_DL in accordance with 1- 2 2760 4601 0.27 This truss has been designed for the effects of an unbalanced top chord ANSI/TPI 1. 2- 3 4941 6217 0.41 live load occurring at [13-08-00] using a 1.00 Full and 0.00 Reduced load 3- 4 6135 10187 0.49 factor. Bracing Data Summary 4- 5 6135 10187 0.48 See Loadcase Report for loading combinations and additional details. ------------Bracing Data------------ 5- 6 6416 10642 0.49 Dead Loads may be slope adjusted: > 12.0/12 Chords; continuous except where shown 6- 7 6416 10642 0.52 Loads based on maximum and minimum reactions from tie-in spans Web Bracing -- None 7- 8 5750 9490 0.48 Domain Max Min Location Dir Description 8- 9 4441 7343 0.55 Transfer loads: Plate offsets (X, Y): 9-10 4021 6599 0.71 TC 170 -162 1-00-12 Vert J17 @ 90 Deg (None unless indicated below) 10-11 2002 3315 0.50 TC 170 -162 3-00-12 Vert J17 @ 90 Deg Jnt2(00-08,0), Jnt8(-00-03,-00-06), 11-OH 3 0 0.00 TC 170 -162 5-00-12 Vert J17 @ 90 Deg Jnt9(-02-04,01-01), Jntl2(0,-01-06), BC OH-12 0 0 0.00 TC 170 -162 7-00-12 Vert J17 @ 90 Deg Jntl3(0,-01-08), Tntl7(0,00-12), 12-13 0 41 0.07 TC 170 -162 9-00-12 Vert J17 @ 90 Deg Jnt20(00-O8,O), Jnt22(0,-01-06) 13-14 4749 2798 0.49 TC 170 -162 11-00-12 Vert J17 @ 90 Deg - 14-15 8217 4857 0.79 TC 170 -162 13-00-12 Vert J17 @ 90 Deg 15-16 10187 6052 0.95 16-17 9490 5667 0.91 TC 170 -162 15-00-12 TC 170 -162 17-00-12 Vert 717 @ 90 Deg Vert J17 @ 90 Deg 17-18 9490 5667 0.64 18-19 6819 4065 0.47 TC 170 -162 19-00-12 TC 170 -162 21-00-12 Vert J17 @ 90 Deg Vert J17 @ 90 Deg IY'• 8 O //j 19-20 6701 4025 0.77 TC 170 -162 23-00-12 Vert J17 @ 90 Deg \\\ �\ J��.•" " " '•. OT 20-21 3011 1807 0.56 21-0 0 0. TC 170 -162 25-00-12 170 -162 27-00-12 Vert J17 @ 90 Deg Vert J17 @ 90 Deg •'' \�\C'EN S+F •' �( _ \ •i i 22-OH OH 0 0 0.0000 TC TC 46 5 29-00-12 Vert J17A @ 90 Deg � Z �' •'� i Web 1-12 2142 3430 0.11 TC 46 5 31-00-12 Vert J17A @ 90 Deg - No. 69577 1-13 5566 3339 0.63 TC 71 -58 33-00-12 Vert J17B @ 90 Deg AN 2-13 1924 2840 0.17 2-14 4070 2441 0.46 3-14 1318 1852 0.11 BC 83 3 1-00-12 BC 83 3 3-00-12 BC 83 3 5-00-12 Vert J17 @ 90 Deg Vert J17 @ 90 Deg Vert J17 @ 90 Deg _ 1 _ - 7� •• 3-15 2387 1901 0.27 BC 83 3 7-00-12 Vert J17 @ 90 Deg ��• 0.� 5-15 772 995 0.07 5-16 1096 292 0.12 BC 83 3 9-00-12 BC 83 3 11-00-12 Vert J17 @ 90 Deg Vert J17 @ 90 Deg '•Ci^ 0 ' STATE OF BC 83 3 13-00-12 Vert J17 @ 90 Deg •••.LOR10?'. •'G\�� 7-16 1351 011 0.15 7-18 993 1278 0.08 BC 83 3 15-00-12 Vert J17 @ 90 Deg 90 / ••. �/ 8-18 3065 1866 0.39 BC 83 3 17-00-12 BC 83 3 19-00-12 Vert J17 @ De g Vert J17 @ 90 Deg / \\ /// DN/1t \ 8-19 639 267 0.07 BC 83 3 21-00-12 Vert J17 @ 90 Deg \ COA /!lfJlll\\\ \ 9-19 230 103 0.02 #30003 0.15 BC 83 3 23-00-12 Vert J17 @ 90 Deg 3/9/2021 9-20 1688 2879 10-20 4228 2543 0.47 BC 83 3 25-00-12 Vert J17 @ 90 Deg NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal an this drawing indicates ® Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector n li r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a'-18" which indicates an 18 gauge plate. or °S# 18% which indicates a high tension 18 gauge plate. - CSHelp@strongtie. com 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: Al Customer: Lu Dial SID: 0000940899 TID: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 2 of 2 ' BC 83 3 27-00-12 Vert J17 @ 90 Deg BC 223 -183 29-00-12 Vert J17A @ 90 Deg �BC 223 -183 31-00-12 Vert J17A @ 90 Deg BC 186 -90 33-00-12 Vert J17B @ 90 Deg 2cPLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC 2x4, 1-row(s) of,10d Nails (0.120" dia. x 2-7/81' min.) @ 12.0" o.c. TC 2x6, 2-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. BC 2x6, 2-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. WB 2x4, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 9.0" o.c. WB 2x8, 2-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 9.0" o.c. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. \\Illlllill//// ��/.•. '•�IGENgF • ..�•� i _ No.69577 �� STATE OF T FZORIOP.•' \ �� COAN3 0 9Z / ONAL I;`\\\ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates E= Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector r aelpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-l8' which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - CSHGIP@Strongtio.com EngDr g: 2019r3RGT Eng 00676 - Lobo - Paleo Pine Circle City: 1 Truss: A2 Customer: Lu Dial SID: 0000940900 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 5-0-13 5-0-13 5-0-11 5-0-13 5-0-13 5-5-8 3-7-8 I 1 5-0-13 10-1-10 I I I I I 15-2-6 20-3-3 25-4-0 30-9-8 34-5-0 1 2 3 4 5 6 7 8 9 - 4x6 4x4= 3x4= 2x3iAx6 3x4= 4x8 -5/12 5x7 3x10 � N ,-i I Ol El 131 'I x6 4x6 4x4= 4x6 5x5= 3x4= 4x8 3x6 5-0-1-3 5-0-1 3-75-8 150-01-13 -0-13 -10 I F 350--59-8 I 15-2-6 4-0 -834--0 10 11 J 12 13 14 15 16 17 J 34-5-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes SC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC - 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L - No R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.25) 13-14 Webs 2x4 SP (ALSC6-2013) #2 10 02-12 1380 710 08-00 02-03 SPF 425 Vert DL L/120 L/999(-0.26) 13-14 2x6 SP (ALSC6-2013) #2 10-1 17 34-03-04 1373 684 01-08 HGR SPF 565 Vert CR L/240 L/787(-0.52) 13-14 Max Horiz - -138 / +0 at Joint 10 Horz LL 0.75in ( 0.05) @Jtl7 Member Forces Summary Horz CR 1.25in ( 0.10) @Jtl7 ...Mem... Ten comp .CSI. Loads Summary TC OH- 1 0 0 0.00 Vert CR and Horz CR are the vertical and 1- 2 1559 1492 0.69 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 2- 3 2666 2554 0.86 live load occurring at [12-08-00] using a 1.00 Full and 0-00 Reduced load plus the creep component of deflection 3- 4 3170 3049 0.89 factor. due to dead load, computed as Defl LL + 4- 5 3170 3049 0.89 See Loadcase Report for loading combinations and additional details. (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. 5- 6 3170 3049 0.81 Dead Loads may be slope adjusted: > 12.0/12 6- 7 3060 2962 0.91 7- 8 2550 2663 0.93 Bracing Data Summary 8- 9 2553 2731 0.70 Notes ------------Bracing Data ------------ 9-OH 0 0 0.00 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Chords; continuous except where shown BC OH-10 0 0 0.00 Plates located at TC pitch breaks meet the prescriptive minimum size ------- Web Bracing -- CLR----------- 10-11 191 69 0.24 requirement to transfer unblocked diaphragm loads across those joints. Single: 1-11 11-12 1534 1418 0.47 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Continuous Restraint Bracing Req'd 12-13 2554 2475 0.61 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. See BCSI-B3 3-0 13-14 2975 2889 0.73 Less than 0.25/12 pitch requires adequate drainage to prevent ponding. 14-15 2402 2241 0.69 Plate offsets (X, l): 15-16 2796 2621 0.77 (None unless indicated below) 16-17 0 0 0.24 Jnt5(0,-00-04), Tnt8(-02-04,01-01), 17-OH 0 0 0.00 Jnt9(-01-08,0), Jntll(0,-00-08), Web 1-10 1465 1337 0.22 Jntl4(0,-01-00), Jntl6(00-08,0) 1-11 1919 2005 0.43 2-11 1318 1098 0.28 2-12 1274 1320 0.88 \� M B 3-13 746 629 0.42 4-13 491 318 0.08 \\\\ `��.,.•••••.O Q�/�l/ 6-13 208 110 0.07 •'.�� i 6-14 521 319 0.09 ��V.''• 7-14 691 775 0.54 No. 69577 7-15 315 77 0.07 r 8-15 390 410 0.22 8-16 1270 1203 0.22 9-16 3003 2807 0.68 9-17 1240 1319 0.22 /l/�•>,. STATE O(/ ECG \\ COA#30003NAL /////1111111\\ 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Belpdesk: 1-866-252-8606 71 plates are 20 gauge, unless the specked plate size is followed by a'-18° which indicates an 18 gauge plate, or °S# 18", which indicates a high tension 18 gauge plate. - CSHelp@strongtie-com EngDrwg: 2019r3RGT_Ps 100676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A3 Customer: Lu Dial SID: 0000940901 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1-0-0 7-5-5 7-5-5 I 7-5-5 I 4-8-12 I 4-8-12 t1-7-8 i-o- 8-5-5 15-10-11 23-4-0 28-0-12 32-9-8 34-5-11 1 2 3 4 5 6 7 8 9 5/12 It 2x35x7 3x4= 2x3114x6 4x6 8-5-5 7-5-5 7-5-5 4-8-12 4-8-12 1-7-8 8-5-5 15-10-11 23-4-0 28-0-12 32-9-8 34-5-0 10 11 12 13 14 15 16 17 1 il 34-5-0 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 2x4 SP (ALSC6-2013) #1 2-5 5-6 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 2x6 SP (ALSC6-2013) #2 18-9 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 3 0 0.00 1- 2 80 74 0.32 2- 3 2016 1928 0.85 3- 4 2670 2566 0.95 4- 5 2670 2566 0.95 5- 6 2670 2566 0.75 6- 7 2361 2460 0.82 7- 8 2687 2908 0.94 8- 9 2101 2257 0.47 9-OH 0 0 0.00 BC OH-10 0 0 0.00 10-11 193 28 0.69 11-12 1928 1680 0.97 12-13 1928 1680 0.74 13-14 2207 1887 0.78 14-15 2207 1887 0.72 15-16 2651 2385 0.78 16-17 2434 2302 0.79 17-18 12 11 0.35 18-OH 0 0 0.00 Web 1-10 199 196 0.06 2-10 1315 1122 0.41 2-11 2014 2044 0.72 3-11 1130 846 0.32 3-13 885 769 0.26 4-13 748 462 0.17 6-13 417 557 0.76 6-15 437 213 0.10 7-15 570 505 0.24 7-16 178 0 0.04 B-16 217 210 0.08 ( 8-17 1383 1306 b.29 9-17 2577 2407 0.58 9-18 1160 1281 0.14 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) - 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B - 54.0 ft M.R.H(h) - 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC - 5.0 End Vertical Exposed: L = No R = Yes Wind Uplift Reporting: ASCE7 MWFRS CSC End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs) ---------------- Jot --X-Loc- React -Up- --Width- -Regd -Mat PSI 10 01-12 1373 712 08-00 02-02 SPF 425 18 34-02-04 1380 682 01-08 HGR SPF 565 Max Horiz = -214 / +20 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [12-02-001 using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. A "pm" next to the plate size indicates that the plate has been user modified; see Plate Offsets for any special positioning requirements. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Less than 0.25/12 pitch requires adequate drainage to prevent pending. ��C/.•. '•��GENSF' • i No. 69577 Q STATE OF ,& .�CORVDP'.•' \�� COA# 0003��ONAL W\\� 3/9/2021 -------Additional Design Checks------ 10psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.20) 10-11 Vert DL L/120 L/999(-0.26) 13-15 Vert CR L/240 L/913(-0.45) 13-15 Herz LL 0.75in ( 0.05) @Jt18 Herz CR 1.25in ( 0.09) @Jt18 Vert CR and Herz CR are the vertical and horizontal deflections due•to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown ------- Web Bracing -- CLR---------- Single: 2-11 3-13 Continuous Restraint Bracing Req'd See SCSI-B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt2(-00-06,-00-02), Jnt5(0,-00-04), JntB(-02-04,01-01), Jnt9(-00-06,-00-02), Jntll(-00-08,0), Jnt14(0,00-04), Jntl8(00-05,-00-07) NOTICE copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates • Truss Studio v ® acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information 8. General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 r plates are 20 gauge, unless the specked plate size is followed by a "-18' which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - . CSHelp@strongtie. c= 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A4 Customer: Lu Dial SID: 0000940902 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 3-0-0 6-1-5 6-2-2 6-9-14 1 3-0-0 9-1-5 15-2-11 21-4-0 27-6-2 1 34-4-0 1 2 3 4 5 6 7 8 5/12 4x6 3x4= Wit 3x6 4x6 3x4u -5/12 3x4-- r rn v 3x6 4-1 3x6 3x4= 4x4= 4x6 3x6 3x6 3x4= Wit 3-0-0 6-1-5 6-1-516-1-5 6-2-2 6-9-14 1 3-0-0 9-1-5 1 1 15-2-1 21-4-0 27-6-2 1 34-4-0 9 10 11 12 13 14 15 16 8 34-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind'Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Pit 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = No R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 6-8 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.15) 15-16 BC 2x9 SP (ALSC6-2013) #2 9 02-12 1369 710 08-00 02-02 SPF 425 Vert DL L/120 L/999(-0.18) 12-15 Webs 2x4 SP (ALSC6-2013) #2 8 34-00-02 1377 681 08-00 02-03 SPF 425 Vert CR L/240 L/999(-0.32) 12-15 2x6 SP (ALSC6-2013) #2 9-1 Max Horiz = -248 /' +59 at Joint 9 Harz LL 0.75in ( 0.05) @Jt 8 Harz CR 1.25in ( 0.10) @Jt 8 Member Forces Summary Loads Summary ..Mem... Ten Comp .CSI. Vert CR and Harz CR are the vertical and TC OH- 1 5 0 0.00 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 1- 2 703 695 0.36 live load occurring at [12-02-00] using a 1.00 Full and 0.00 Reduced load plus the creep component of deflection 2- 3 1736 1661 0.86 factor. due to dead load, computed as Defl LL + 3- 4 2159 2103 0.94 See Loadcase Report for loading combinations and additional details. (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. 4- 5 2159 2103 '0.94 Dead Loads may be slope adjusted: > 12.0/12 5- 6 2159 2103 0.74 6- 7 2068 2242 0.69 Bracing Data Summary 7- 8 2452 2812 0.73 Notes ------------Bracing Data ------------ BC OH- 9 0 0 0.00 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Chords; continuous except where shown 8-16 2526 2073 0.78 Plates located at TC pitch breaks meet the prescriptive minimum size ------- Web Bracing -- CLR----------- 9-10 397 125 0.26 requirement to transfer unblocked diaphragm loads across those joints. Single: 2-11 10-11 619 392 0.41 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Continuous Restraint Bracing Req'd 11-12 1661 1385 0.57 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. See BCSI-133 3.0 12-13 1993 1525 0.60 13-14 1993 1525 0.50 Plate offsets (X, Y): 14-15 1993 1525 0.64 (None unless indicated below) 15-16 2526 2073 0.73 Web 1- 9 1370 1359 0.28 1-10 1164 1110 0.47 2-10 995 885 0.45 2-11 1369 1396 0.43 3-11 972 763 0.40 \\\\JIIIiIJJJ11 4-12 605 370 0.19 \\\\���..M•BopT�!!! 6-12 195 308 0.36 6-15 439 219 0.11 \ ,•• �10ENS+F ,(_ .•-% i 7-15 643 593 0.45 \ ��.' 7-16 226 0 0.05 = NO. 69577 X` . �. Q STATE OF ((/� 'ice 'cCORl0?.•' ECG \\ AL COA#30003 I11 1 1 1 11 \ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General - 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector ^ Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a'-18' which indicates an 18 gauge plate, or "S# 18', which indicates a high tension 18 gauge plate. - cSHe1p@strongt1e. corn Eng0r.g: 2019z311GT PS 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A5 Customer: Lu Dial SID: 0000940903 TID: 122969 ' Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 5-0-0 7-9-1 -4-Q 116--4a--D1 5-0-0 0 I 2 I 12-1-0 19-4-0 6-6-2 34-4-1 0 23 4 5 67 8� 5/12 4x4= 3x6 3x4= 4x6 3x6 2x3ii -5/12 3x4-- n - � v 3x4= 4-1 X 3x6 3x6 4x4= 3x6 4x6 3x6 2x3n 6-4-0 6-6-0 6-6-0 7-2-2 7-9-14 I 6-4-0 I I 12-10-0 19-4-0 26-6-2 34-4-0 9 10 11 12 13 14 15 8 F 34-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) - 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) - 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L= Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Sunsnary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.08) 13-15 Webs 2x4 SP (ALSC6-2013) #2 9 02-12 192 559 08-00 00-05 SPF 425 Vert DL L/120 L/999(-0.11) 13-15 2x6 SP (ALSC6-2013) #2 9-1 10 6-04-00 2230 1086 08-00 03-08 SPF 425 Vert CR L/240 L/999(-0.19) 13-15 10-3 8 34-00-02 1061 561 08-00 01-11 SPF 425 Horz LL 0.75in ( 0.02) @Jt 8 Max Horiz = -418 / +229 at Joint 9 Horz CR 1.25in ( 0.03) @Jt 8 Member Forces Summary ohng CR 2L/240 2L/999 ( 0.02) 8- 8 ..Mem... Ten comp .CS1. Loads Summary TC OH- 1 5 0 0.00 Vert CR and Horz CR are the vertical and 1- 2 207 75 0.63 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 2- 3 657 314 0.57 live load occurring at (12-02-00] using a 1.00 Full and 0.00 Reduced load plus the creep component of deflection 3- 4 713 406 0.86 factor. due to dead load, computed as Defl LL + 4- 5 986 897 0.91 See Lbadcase Report for loading combinations and additional details. (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. 5- 6 986 978 0.53 Dead Loads may be slope adjusted: > 12.0/12 6- 7 973 7- 8 1351 1063 0.88 1605 0.94 Bracing Data Summary 8-0H 35 0 0.26 Notes No------------Bracing Data ------------ BC OH- 9 0 0 0.00 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Chords; continuous except where shown 8-15 1594 960 0.68 Plates located at TC pitch breaks meet the prescriptive minimum size ------- Web Bracing -- CLR----------- 9-10 672 506 0.52 requirement to transfer unblocked diaphragm loads across those joints. Single: 3-11 10-11 758 657 0.52 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Continuous Restraint Bracing Req'd 11-12 406 162 0.46 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. See SCSI-B3 3.0 12-13 406 162 0.46 13-14 1594 960 0.64 Plate offsets(X, 1): 14-15 1594 960 0.68 , (None unless indicated below) Web 1- 9 295 141 0.16 2- 9 825 591 0.63 2-10 699 722 0.52 3-10 1376 1378 0.61 3-11 1445 4-11 938 1882 0.61:•6 \llltlliiJ//� 4-13 708 398 0.57 \� ��\ •,• ••• OT 5-13 153 7-13 618 26 0.03 770 0.80 / .••\iiEN$F '•. �� i \ 7-15 293 0 0.06 �� l No.69577 _ / Q STATE -OF T i .FCORISP'•. ^' COA# 00030'VAI I 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates ® Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector ` r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a •-18" which indicates an 18 gauge plate, or'S# 18•, which indicates a high tension 18 gauge plate. - CSHelp@strongtie. com engurwg: �uiyr�n -r� 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A6 Customer: Lu Dial SID: 0000940904 TID: 122969 Date: 03 108 ! 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 5-3-0 5-5-7 5-5-7 6-1-3 1-4-g 7-0-0 I 12-1-0 17-4-0 22-9-7 28-2-13 34-4-0 ' 1 2 3 4 5 6 7 8 5/12 4x6 3x4= 4x4= 3x4-- -5/12 3x4= 3x6 ti 2x3,p � ^ � r ^ ui i v 4x4= 4-1 2x311 3x6 3x6 4x6 3x6 3x4= 6-0-0 6-4-0 5-9-0 5-3-0 8-2-2 8-9-14 6-4-0 12-1-0 17-4-0 25-6-2 34-4-0 9 10 11 12 13 14 8 34-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin):' No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = No R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.11) 14- 8 Webs 2x4 SP (ALSC6-2013) #2 10 6-04-00 1668 865 08-00 02-10 SPF 425 Vert DL L/120 L/999(-0.15) 12-14 2x6 SP (ALSC6-2013) #2 10-2 8 34-00-02 1167 589 08-00 01-13 SPF 425 Vert CR 1/240 L/999(-0.25) 12-14 Max Horiz = -331 / +116 at Joint 10 Horz LL 0.75in ( 0.03) @Jt 8 Member Forces Summary Horz CR 1.25in ( 0.05) @Jt a ...Mem... Ten comp .CSI. Loads Summary Ohng CR 2L/240 2L/999( 0.02) 8- 8 TC OH- 1 3 0 0.00 Cant CR 2L/240 2L/999( 0.05) 9-10 1- 2 325 270 0.88 This truss has been designed for the effects of an unbalanced top chord 2- 3 706 621 0.54 live load occurring at (12-02-00] using a 1-00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and 3- 4 949 992 0.56 factor. horizontal deflections due to live load 4- 5 958 1146 0.46 See La Report for loading combinations and additional details. plus the creep component of deflection 5- 6 1380 1799 0.51 Dead Loads may be slope adjusted: > 12.0/12 Loads due to dead load, computed as Defl LL + - 6- 7 1373 1885 0.66 Kcr - 1) x Defl DL in accordance with (- 7- 8 1571 2146 0.75 ANSI/TPI 1. 8-OH 35 0 0.26 Notes BC OH- 9 0 0 0.00 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Bracing Data Summary B-14 1920 1154 0.87 Plates located at TC pitch breaks meet the prescriptive minimum size ------------Bracing Data ------------ 9-10 0 0 0.42 requirement to transfer unblocked diaphragm loads across those joints. Chords; continuous except where shown 10-11 536 265 0.42 Continuous Lateral Restraint (CLR) rows require diagonal bracing per ------- Web Bracing -- CLR----------- 11-12 637 90 0.51 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Single: 2-11 12-13 1482 689 0.64 Continuous Restraint Bracing Req'd 13-14 1482 689 0.81 See BCSI-B3 3.0 Web 1- 9 103 132 0.04 1-10 430 272 0.26 Plate offsets (X, Y): 2-10 1366 1373 0.75 (None unless indicated below) 2-11 1092 938 0.33 JntB (0,00-02), Jntll (0,-00-08) 3-11 811 793 0.71 � 3-12 631 402 0.55 `}►V' 5-12 538 658 0.59 ���`\, 8O/j� 5-14 471 269 0.14 - �� `�� ,.•••••.•• 0 // V 7-14 486 313 0.08 ••' �,CEN S.� •• �(_ \ i i No.69577 _ 0or STATE OF � ^ FLORVDP.•N\ /0NAL COA #30003l01 i l l l i t t\�\ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a'-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. e a - CSHelp@strongtie. core EngDrwg: 2019r3RGT_PS C0676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A7 Customer: Lu Dial SID: 0000940905 TID: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 6-4-0 10-8 2-0-Oil-9-8 4-4-0 6-1-7 6-1-7 6-9-3 1-4� i6-4-0 I 15-4-0 21-5=7 27-6-13 34-4-0 z2-3g1-0-5 6 7 8 9 5/12 4x4= 4x4= 5/12 4x4= Sx5- 2x4 SxS� /12 3x4= � N r ao E?,� 0 � � >-5 m u; 4x4= 4-1 2x3ii Sx10 4x8 3x6 4x6 3x6 3x4= 6-0-0 6-4-0 2-10-8 6-1-8 9-2-2 9-9-14 6-4-0 I 9-2-8 15-4-0 24-6-2 34-4-0 10 11 12 13 14 15 16 9 34-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B = 54.0 ft 200 1b BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = No R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.17) 14-16 2x9 SP (ALSC6-2013) #1 15-9 11 6-04-00 1668 864 08-00 02-10 SPF 425 Vert DL L/120 L/999(-0.17) 14-16 Webs 2x4 SP (ALSC6-2013) #2 9 34-00-02 1163 590 08-00 01-13 SPF 425 Vert CR L/240 L/962(-0.34) 14-16 2x6 SP (ALSC6-2013) #2 11-2 Max Horiz = -366 / +152 at Joint 11 Horz LL 0.75in ( 0.03) @Jt 9 Horz CR 1.25in ( 0.05) Bit 9 Member Forces Summary Loads Summary Ohng CR 2L/240 2L/999 ( 0.02) 9- 9 ..Mem... Ten Comp .CSI. Cant CR 2L/240 2L/999( 0.05) 10-11 TC OH- 1 3 0 0.00 This truss has been designed for the effects of an unbalanced top chord 1- 2 289 238 0.76 live load occurring at [13-02-00] using a 1.00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and 2- 3 221 48 0.78 factor. horizontal deflections due to live load 3- 4 368 281 0.09 See Loadcase Report for loading combinations and additional details. plus the creep component of deflection 4- 5 419 323 0.10 due to dead load, computed as De£1_LL + Dead Loads may be slope adjusted: > 12.0/12 5- 6 773 810 0.36 (Kcr - 1) x Defl DL in accordance with 6- 7 762 957 0.55 ANSI/TPI 1. 7- 8 1231 1812 0.75 Notes 8- 9 1438 2114 0.83 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Bracing Data Summary 9-OH 35 0 0.26 Plates located at TC pitch breaks meet the prescriptive minimum size ------------Bracing Data ------------ BC OH-10 0 0 0.00 requirement to transfer unblocked diaphragm loads across those joints. Chords; continuous except where shown 9-16 1887 1019 0.76 Continuous Lateral Restraint (CLR) rows require diagonal bracing per ------- Web Bracing -- CLR----------- 10-11 0 0 0.37 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Single: 12- 5 11-12 530 246 0.38 Continuous Restraint Bracing Req'd 12-13 451 14 0.40 See BCSI-B3 3.0 13-14 451 14 0.74 14-15 1370 530 0.88 Plate offsets (X, l): 15-16 1370 530 0.71 (None unless indicated below) Web 1-10 106 126 0.04 Jnt2(0,01-00), Jnt4(02-04,01-01), 1-11 358 229 0.22 Jnt7(00-06,00-15), Tnt9(0,00-02), 2-11 881 603 0.31 �ti�lllil/// Jntll(0,-00-07) 3-11 518 3-12 1035 933 789 0.83 0.76 �\�\ ` M • 80 4-12 277 230 0.21 \�`�\ •,.•••••., Off, 5-12 604 5-14 750 771 476 0.24 0.69 ` /�V ��G EnJS+� •,• �(_ i •'•� 6-14 141 0 0.03 �•' 7-14 604 750 0.85 No.69577 7-16 545 293 0.20 _ _ 8-16 524 368 0.12 Q STATE OF coA# 000s/ /111NAI. 11 1 it 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates • Truss Studio v acceptance of professional engineering responsibility solelyfor the truss component design shown. Seethe cover page and the 'Important Information 8: General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, ar •S# 18", which indicates a high tension 18 gauge plate. ^ - CSHelp@strongtie.com EngDrwg: 2019r3RGT_Eng 90676 - Lobo - Paleo Pine Circle City: 1 Truss: A8 Customer: Lu Dial SID: 0000940906 TID: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 5-24 2-0-0 5-11-8 6-10-1 6-10-1 7-5-13 5-2-8 7-2-8 13-2-0 20-0-1 26-10-3 34-4-0 1 2 3 4 5 6 7 4k+0 5/12 4x4= - 5/12 4x4= 4x6 SxS� -5/12 3x4= m 3x4-- � 00 i � 4x4= 4-1 X 2x3 o 3x4=x6 3x6 4x6 3x4= 3x6 2x3 ii 6-0-0 5-2-8 -1- 6-11-0 6-10-1 6-10-1 7-5-13 5-2-8 -4 13-2-0 20-0-1 26-10-3 34-4-0 8 9 10 11 12 13 14 15 7 34-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary , Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 5-7 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.09) 13-15 BC 2x4 SP (ALSC6-2013) #2 10 6-04-00 1671 852 08-00 02-10 SPF 425 Vert DL L/120 L/999(-0.11) 13-15 Webs 2x4 SP (ALSC6-2013) #2 7 34-00-02 1103 534 08-00 01-12 SPF 425 Vert CR L/240 L/999(-0.19) 13-15 2x6 SP (ALSC6-2013) #2 10-3 Max Horiz = -511 / +352 at Joint 10 Horz LL 0.75in ( 0.03) @Jt 7 Horz CR 1.25in ( 0.06) @Jt 7 Member Forces Summary Loads Summary Cant CR 2L/240 2L/999 (-0.03) 8- 9 ..Me"... Ten Comp .CSI. TC OH- 1 3 0 0.00 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 1- 2 221 248 0.51 live load occurring at [13-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 2- 3 239 288 0.16 factor. plus the creep component of deflection 3- 4 602 711 0.44 due to dead load, computed as Defl_LL + See Loadcase Report for loading combinations and additional details. 4- 5 592 733 0.66 (Kcr - 1) x Defl DL in accordance with Dead Loads may be slope adjusted: > 12.0/12 - 5- 6 969 1442 0.79 ANSI/TPI 1. 6- 7 1512 BC 0H- 8 0 2121 0.91 0 0.00 Notes Bracing Data Summary 7-15 1887 1151 0.67 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ 8- 9 129 114 0.22 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 9-10 250 149 0.45 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 10-1.1 526 232 0.45 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 12- 4 12- 5 11-12 526 232 0.41 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 12-13 1252 415 0.59 See BCSI-B3 3.0 13-14 1887 1151 0.67 14-15 1887 1151 0.67 Plate offsets (X, Y): Web 1- 8 88 104 0.33 (None unless indicated below) 1- 9 273 195 0.14 Jnt3(-00-01,00-03), Jnt5(00-06,00-15), 2- 9 185 404 0.28 Tnt7(0,00-02) 2-10 761 474 0.34 3-10 765 1104 0.51 4-12 2115 107 0.05 ��►Iliiij�� 5-12 693 5-13 491 888 0.34 274 0.17 \\ �•,.•••••.,• Q� '` •••.-% 6-13 850 694 0.68 L ,LENS F 6-15 278 0 0.06 ��/,••• No.69577 Q STATE OF . .� ( l III I II1o'\�\ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by -the Building Designer. Aseal on this drawing indicates 0 Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tire Company, Inc in accordance with ESR-2762. All connector - Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. e 3 - CSHelp@strongtie, com EngDr g: 2019r311G1-Eng Q0676 - Lobo - Paleo Pine Circle Qty: 4 Truss: A9 Customer: Lu Dial SID: 0000940907 TID: 122969 Date: 03 if 08 ! 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 6-4-0 6-10-0 6-10-1 6-10-1 7-5-13 6-4-0 13-2-0 20-0-1 26-10-3 34-4-0 1 2 3 4 5 6 4x4i 5/12 4x4� 5x7 -5/12 v 3x4= rn 3x4 c , m 4x4= 4-1 2x31I 3x6 3x6 4x6 3x4= 3x6 2x31i 6-0-0 6-4-0 6-10-0 6-10-1 6-10-1 7-5-13 620-0-1 26-10-3 34-4-0 7 8 9 10 it 12 13 6 34-4-0 r Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) - 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(l.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = No R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) 91 4-6 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.09) 11-13 BC 2x4 SP (ALSC6-2013) #2 8 6-04-00 1671 860 08-00 02-10 SPF 425 Vert DL L/120 L/999(-0.11) 11-13 Webs 2x4 SP (ALSC6-2013) #2 6 34-00-02 1104 532 08-00 01-12 SPF 425 Vert CR L/240 L/999(-0.19) 11-13 2x6 SP (ALSC6-2013) #2 8-2 Max Horiz = -386 / +246 at Joint 8 Horz LL 0.75in ( 0.03) @it 6 Horz CR 1.25in ( 0.06) @Jt 6 Member Forces Summary Loads Summary Cant CR 2L/240 2L/999 ( 0.04) 7- 8 ..Mem... Ten Comp .CSI. TC OH- 1 3 0 0.00 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 1- 2 316 289 0.90 live load occurring at 113-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 2- 3 822 731 1.00 factor. plus the creep component of deflection 3- 4 819 733 0.86 due to dead load, computed as Deft LL + a See LReport for loading combinations and additional details. 4- 5 1364 1442 0.91 (Kcr - 1) x Defl_DL in accordance with Loads Dead Loads may be slope adjusted: > 12.0/12 5- 6 2020 2122 0.99 ANSI/TPI 1. BC OH- 7 0 0 0.00 6-13 1887 1618 0.67 PtOteS Bracing Data Summary _ 7- 8 0 0 0.46 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------ Bracing Data ------------ 8- 9 614 292 0.46 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 9-10 614 292 0.38 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 10-11 1252 683 0.58 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 2-10 10- 3 10- 4 11-12 1887 1618 0.68 .D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 12-13 1887 1618 0.67 See BCSI-B3 3.0 Web 1- 7 100 137 0.03 1- 8 382 251 0.21 Plate offsets (X, l): 2- 8 1489 1409 0.56 (None unless indicated below) 2-10 977 764 0.28 Jnt3(0,00-15), Jnt4(00-06,00-15), 3-10 211 123 0.04 Jnt6(0,00-02) 4-10 1002 898 0.34 4-11 493 348 0.21 5-13 1278 023 69 0 0.06 \�1\Il M \\�`\\� •'" ..E3OO'/�// ��.•� �,�ENSF' ..yam _; No.69577 Q STATE Oi. F • 41 'c40R1DN.•' G�=� S/ONAL E� COA #s000s ! I l I I i l X l 3/9/2021 NOTICE A copy of this design shall be fumished,to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates Truss Studio V ® acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or'S# 18', which indicates a high tension 18 gauge plate. n F - CSHelp@strongtie. com EngDrwg: 2019r3RGT_PS 00676 - Lobo - Paleo Pine Circle City: 1 Truss: A10 Customer: Lu Dial SID: 0000940908 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 5-5-15 7-8-1 6-10-1 6-10-1 7-5-13 5-5-15 13-2-0 20-0-1 1 26-10-3 1 34-4-0 1 2 3 4 5 6 4x4// 5/12 4x4o Sx7 -5/12 3x4= 3x4� o: m n 4x4= 4-1 2x3ii x6 4x6 3x6 Sx10 2x3n 5-0-5I 5-5-15 7-8-1 6-10-1 6-10-1 7-5-13 5-5-15 1 13-2-0 20-0-1 26-10-3 1 34-4-0 7 8 9 10 11 12 6 b 34-4-0 r Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead our Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 ps£ BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 £t B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Pit 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = No R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 ps£ C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #2 3-4 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.09) 11-12 BC 2x4 SP (ALSC6-2013) #2 8 5-05-15 1622 835 11-05 02-09 SPF 425 Vert DL L/120 L/999(-0.11) 11-12 Webs 2x4 SP (ALSC6-2013) #2 6 34-00-02 1145 557 08-00 01-13 SPF 425 Vert CR L/240 L/999(-0.20) 11-12 2x6 SP (ALSC6-2013) #2 8-2 Max Horiz = -386 / +246 at Joint 8 Horz LL 0.75in ( 0.03) @Jt 6 Horz CR 1.25in ( 0.06) @Jt 6 Member Forces Summary Loads Summary Cant CR 2L/240 2L/999 ( 0.04) 7- 8 ..Mem... Ten Comp .CSI. TC OH- 1 3 0 0.00 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 1- 2 248 215 0.68 live load occurring at [13-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 2- 3 914 852 0.76 factor. plus the creep component of deflection 3- 4 925 842 0.86 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + (Kcr - 1) x Defl_DL in accordance with 4- 5 1492 1566 0.93 Dead Loads may be slope adjusted: > 12.0/12 ANSI/TPI 1. 5- 6 2123 2221 1.00 BC OH- 7 0 0 0.00 6-12 1978 1712 0.65 Notes Bracing Data Summary 7- 8 0 0 0.46 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data------------ 8- 9 557 235 0.49 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 9-10 1343 791 0.68 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 10-11 1343 791 0.57 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 2- 9 9= 4 11-12 1978 1712 0.67 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd Web 1- 7 79 123 0.02 See BCSI-B3 3.0 1- 8 296 199 0.13 2- 8 1453 1382 0.49 Plate offsets (X,1): 2- 9 987 757 0.30 (None unless indicated below) 3- 9 277 155 0.21 Jnt3(0,00-15), Jnt4(00-06,00-15), 4- 9 998 877 0.33 Jnt6(0,00-02), Jntll(0,-01-00) 4-11 487 362 0.22 5-11 1006 673 0.66 5-12 267 0 0.06 \�1IIII1IJ/// \\�� �• //�/ go ,. ' ��GENgF • ..�•� � �� No.69577 • I0 • STATE OF 41/ 0�i � 'QCORIDP.•'•G\ �� � COA#30003V/ONAk- /llllll , 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by OT Component Solutions M-l"'Al the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a •-18" which indicates an 18 gauge plate, or •S# 18", which indicates a high tension 18 gauge plate. n t - CsHelp@strongue.com EngDrwg: 2019r3RGT_PS 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A11 Customer: Lu Dial SID: 0000940909 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 3-5-15 4-10-1 4-10-1 6-10-1 6-10-1 7-5-13 1 3-5-15 1 8-4-0 13-2-0 20-0-1 26-10-3 34-4-0 1 2 3 4 5 6 7 4x4o 5/12 3x4- 5x7 -5/12 2x3ii 1 3x4= a, 3x4 a m 4x4= 4-1 2x3ii x1 3x6 4x6 3x4= 3x6 2x3ii 3 0 5 3-5-15 9-8-1 6-10-1 6-10-1 7-5-13 3-5-15 1 13-2-0 %-0-1 26-10-3 34-4-0 8 9 10 11 12 13 14 7 34-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No spacing: 2-00-00 O.C. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 5-7 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL _L/360 L/999(-0.23) 9-11 BC 2x4 SP (ALSC6-2013) #1 9 3-05-15 1516 772 11-05 02-06 SPF 425 Vert DL L/120 L/999(-0.19) 9-11 2x4 SP (ALSC6-2013) #2 13-7 7 34-00-02 1238 620 08-00 01-15 SPF 425 Vert CR L/240 L/867(-0.42) 9-11 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz = -484 / +365 at Joint 9 Horz LL 0.75in ( 0.04) @Jt 7 2x6 SP (ALSC6-2013) #2 9-2 Horz CR 1.25in ( 0.07) @Jt 7 Loads Summary Cant CR 2L/240 2L/999 ( 0.04) 8- 9 Member Forces Summary ..Mem-.. Ten Comp -CSI. This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and TC OH- 1 3 0 0.00 live load occurring at [13-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 1- 2 106 172 0.33 factor. plus the creep component of deflection 2- 3 242 75 0.38 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + 3- 4 1201 1051 0.53 Dead Loads may be slope adjusted: > 12.0/12 (Kcr - 1) x Defl_DL in accordance with 4- 5 1178 1081 0.95 ANSI/TPI 1. 5-6 1729 1780 0.93 6- 7 2367 2448 1.00 Notes Bracing Data Summary BC OH- 8 0 0 0.00 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ 7-14 2186 1935 0.71 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 8- 9 101 90 0.67 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 9-10 693 211 0.74 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 9- 3 11- 5 10-11 693 211 0.70 D-WEBCLRBRACE- Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 11-12 1566 1027 0.79 See SCSI-B3 3.0 12-13 2186 1935 0.46 13-14 2186 1935 0.71 Plate offsets (X, 1f): Web 1- 8 19 96 0.21 (None unless indicated below) 1- 9 161 85 0.03 Jnt4(0,00-15), Jnt5(00-06,00-15), 2- 9 454 276 0.07 Jnt7(0,00-02), Jnt9(0,-00-08) 3- 9 1132 1241 0.40 3-11 436 185 0.22 4-11 374 464 0.64 5-11 1014 875 0.33 5-12 466 348 0.21 ` BO ��•�\C OT'(_ 1000 682 0.66 �� 6-12 6-14 278 0 0.06 ENS+ \ V -i No.69577 =_ �� _ Q STATE"OF C(/ F<P' N_� OR\D •��C� /,�Fss�O• . �. AI. COA#30003 3/9/2021 NOTICE copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates ® Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. M - CSHelp@strongtie.com EnaDI 2019r3RGT PS 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: Al2 Customer: Lu Dial SID: 0000940910 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1-s-1S 4-10-0 6-10-1 6-10-1 6-10-1 7-5-13 1-4-. i 6-3-15 1 13-2-0 20-0-1 26-10-3 34-4-0 1 2 3 4 5 6 7 8 4x6 5/12 3x4- 3x43x6 -5/12 H 4x4� rn 3x4= 3x4 m m 4x4= 4-1 Wigx6 3x4= 3x6 4x6 3x4= 3x6 2xh -s-1 4-10-0 6-10-1 6-10-1 6-10-1 7-5-13 s-1 6-3-15 13-2-0 20-0-1 26-10-3 34-4-0 9 10- 11 12 13 14 15 16 8 34-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(l.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #2 1-4 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.13) 14-16 BC 2x4 SP (ALSC6-2013) #2 10 1-05-15 1420 722 11-05 02-04 SPF 425 Vert DL L/120 L/999(-0.16) 14-16 Webs 2x4 SP (ALSC6-2013) #2 8 34-00-02 1411 732 08-00 02-03 SPF 425 Vert CR L/240 , L/999(-0.29) 14-16 2x6 SP (ALSC6-2013) #2 10-2 Max Horiz = -505 / +346 at Joint 10 Horz LL 0.75in ( 0.04) @Jt 8 Horz CR 1.25in ( 0.08) @Jt 8 Member Forces Summary Loads Summary Ohng CR 2L/240 2L/999 ( 0.01) 8- 8 ..Mem... Ten Comp .CSI. Cant CR 2L/240 2L/999( 0.02) 9-10 TC 011- 1 3 0 0.00 This truss has been designed for the effects of an unbalanced top chord 1- 2 102 91 0.20 live load occurring at [13-02-00] using a 1.00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and 2- 3 1040 1048 0.81 factor, horizontal deflections due to live load 3- 4 1357 1295 0.86 See Loadcase Report forloading combinations and additional details. plus the creep component of deflection 4- 5 1359 1298 0.69 Dead Loads may be slope adjusted: > 12.0/12 due to dead load, computed as Defl_LL + 5- 6 1861 1863 0.74 (Kcr - 1) x Defl_DL in accordance with 6- 7 1857 1999 0.82 ANSI/TPI 1. 7- 8 2370 2646 0.87 Notes 8-OH 35 0 0.19 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Bracing Data Summary BC OH- 9 0 0 0.00 Plates located at TC pitch breaks meet the prescriptive minimum size ------------Bracing Data ------------ B-16 2366 1856 0.75 requirement to transfer unblocked diaphragm loads across those joints. Chords; continuous except where shown 9-10 100 89 0.13 Continuous Lateral Restraint (CLR) rows require diagonal bracing per ------- Web Bracing -- CLR----------- 10-11 452 276 0.32 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Single: 13- 5 11-12 928 418 0.46 Continuous Restraint Bracing Req'd 12-13 928 418 0.56 See BCSI-B3 3.0 13-14 1775 1185 0.69 ' 14-15 2366 1856 0.75 Plate offsets (X, Y): 15-16 2366 1856 0.70 (None unless indicated below) Web 1- 9 18 33 0.21 Tnt8(0,00-02) 1-10 29 23 0.00 2-10 1318 1339 0.24 2-11 1193 1022 0.67 OO�/�// 3-13 325 207 0.29 \\\\ `��• , . • • • • • . 9-13 570 5-13 956 517 0.71 881 0.33 \ V �CENS .• �/ F' -Y i 5-14 480 279 0.17 7-14 828 651 0.63 No.69577 7-16 266 0 0.06 _ STATE OF i ' • 'r�OR10 \_� COA#30003///011lil\\\\ 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General .2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. Allconnector r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a'-18" which indicates an 18 gauge plate, or "S# 18°, which indicates a high tension 18 gauge plate. n - CSHelp@strongtie. com EngDrwg: 2019r3RGT_PS 00676 - Lobo - Paleo Pine Circle Qty: 2 Truss: A13 Customer: Lu Dial SID: 0000940911 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 -4-9 7-5-13 6-10-16-10-1 6-10--1 7-5-13 -4- 9 r� 7-5-13 I 14-3-15 280 4-10321-2-0 42-4-0 4x6 5/12 3x44x6 -5/12 4x63x4- 3x4- 3x4- Sx7 Sx7 4-1 4-1 x 2x4 3x4= 3x6 4x6 3x6 3x4= 2x4 7-5-13 6-10-1 6-10-1 6-10-1 6-10-1 7-5-13 7-5-13 i 14-3-15 21-2-0 28-0-1 34-10-3 42-4-0 1 y" 10 11 12 13 14 15 16 9 42-4-0 ' Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dux Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt - 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.24) 13-15 Webs 2x4 SP (ALSC6-2013) #2 1 04-00 1778 921 08-00 02-13 SPF 425 Vert DL L/120 L/999(-0.28) 13-15 Wedge 2x4 SP (ALSC6-2013) #2 9 42-00-00 1778 921 08-00 02-13 SPF 425 Vert CR L/240 L/965(-0.52) 13-15 Max Horiz = -392 / +392 at Joint 1 Horz LL 0.75in ( 0.10) @it 9 Member Forces Summary Horz CR 1.25in ( 0.20) @Jt 9 ...Mem... Ten comp .CSI. Loads Summary Chug CR 2L/240 2L/999( 0.01) 1- 1 TC OH- 1 35 0 0.19 Ohng CR 2L/240 2L/999( 0.01) 9- 9 1- 2 3070 3497 0.80 This truss has been designed for the effects of an unbalanced top chord 2- 3 2634 2913 0.75 live load occurring at [21-02-00] using a 1.00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and 3- 4 2638 2777 0.85 factor. horizontal deflections due to live load 4- 5 2164 2225 0.80 See La Report for loading combinations and additional details. plus the creep component of deflection 5- 6 2164 2225 0.80 Loads Dead Loads may be slope adjusted: > 12.0/12 due to dead load, computed as Defl LL + 6- 7 2638 2777 0.85 (Kcr - 1) x Defl_DL in accordance with 7- 8 2634 2913 0.76 ANSI/TPI 1. 8- 9 3070 3497 0.81 Notes 9-OH 35 0 0.19 Plates designed for Cq at 0.60 and Rotational Tolerance of 10.0 degrees Bracing Data Summary BC 1-10 3158 2635 0.88 Plates located at TC pitch breaks meet the prescriptive minimum size ------------Bracing Data ------------ 9-16 3158 2570 0.88 requirement to transfer unblocked diaphragm loads across those joints. Chords; continuous except where shown 10-11 3158 2635 0.90 Continuous Lateral Restraint (CLR) rows require diagonal bracing per ------- Web Bracing -- CLR----------- 11-12 2621 1985 0.81 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Single: 4-13 13- 5 13- 6 12-13 2621 1985 0.79 Continuous Restraint Bracing Req'd 13-14 2621 1974 0.79 See BCSI-B3 3.0 14-15 2621 1974 0.81 15-16 3158 2570 0.90 Plate offsets(X, Y): Web 2-10 248 0 0.05 (None unless indicated below) 2-11 715 613 0.60 Jnt3(00-02,-00-04), Jnt7(-00-02,-00-04), 4-11 472 232 0.14 Jntl(04-14,01-08), Jnt9(-04-14,01-08) 4-13 931 874 0.335-13 6-13 1267 931 151 0.41 1874 0.33 Illlllil/// ��NI so 6-15 472 232 0.14 �\ �T 8-15 715 8-16 248 613 0.60 0 0.05 \\ '• IGEN$ ` % F ••' -Y i No.69577 =_ Xr ,STATE.11 °<ORIOP'. •- ' COA#30003�///]Yiltll�\\ 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates • Truss Studio V ® acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a •-18" which indicates an 18 gauge plate, or °S# 18•, which indicates a high tension 18 gauge plate. r B - CSHelp@strongtie. com EngDrwg: 2019r3RGT PS 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A14 Customer: Lu Dial SID: 0000940912 TID: 122969 Date: 03 108 121 Truss Mfr. Contact: Rick Mills Page: 1 of 1 ik 7-5-13 6-10-1 6-10-1 6-10-1 6-10-1 7-5-13 i 7-5-13 1 14-3-15 21-2-0 28-0-1 34-10-3 42-4-0 1 2 3 4 5 6 7 8 4x6 5/12 5x7 -5/12 4x63x4� rn 3x4 3x4 �? m Sx7 :�5x7 4-1 4-1 x 2x4 3x4= 3x6 4x6 3x6 3x4= 2x4 7-5-13 6-10-1 6-10-1 6`10-1 6-10-1 7-5-13 7-5-13 14-3-15 21-2-0 28-0-1 34-10-3 42-4-0 1 9 10 11 12 13 14 15 8 42-4-0 Code/Design: FBC-2020/TPI-2014 -------- ---Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-1� Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf CSC End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd. -Mat PSI Vert LL L/360 L/999(-0.24) 12-14 Webs 2x4 SP (ALSC6-2013) #2 1 04-00 1780 923 08-00 02-13 SPF 425 Vert DL L/120 L/999(-0.28) 12-14 Wedge 2x4 SP (ALSC6-2013) #2 8 42-00-00 1691 857 08-00 02-10 SPF 425 Vert CR L/240 L/964(-0.52) 12-14 Max Horiz = -372 / +411 at Joint 1 Horz LL 0.75in ( 0.10) @Jt 8 Member Forces Summary Horz CR 1.25in ( 0.20) @Jt 8 ...Mem... Ten comp .csl. Ohng CR 2L/240 2L/999( 0.01) 1- 1 Loads Summary TC OH- 1 35 0 0.19 1- 2 3074 3502 0.80 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 2- 3 2647 2918 0.75 live load occurring at [21-02-001 using a 1.00 Full and 0-00 Reduced load horizontal deflections due to live load 3- 4 2651 2782 0.85 factor. plus the creep component of deflection 4- 5 2192 2230 0.80 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + (Kcr - 1) x Defl_DL in accordance with 5- 6 2192 2229 0.79 Dead Loads may be slope adjusted: > 12.0/12 ANSI/TPI 1. 6- 7 2699 2921 0.86 7- 8 3210 BC 1- 9 3162 3527 0.91 2686 0.88 Notes Bracing Data Summary 8-15 3189 2747 0.82 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ 9-10 3162 2686 0.90 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 10-11 2626 2037 0.81 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 11-12 2626 2037 0.79 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 4-12 12- 5 12- 6 12-13 2620 2021 0.79 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 13-14 2620 2021 0.81 See BCSI-B3 3.0 14-15 3189 2747 0.90 Web 2- 9 248 0 0.05 ( Plate offsets (X, Y): 2-10 714 613 0.60 (None unless indicated below) 4-10 472 232 0.14 Jnt3(00-02,-00-04), Tnt6(00-06,00-15), 4-12 932 874 0.33 Jntl(04-14,01-08), JntB(-04-14,01-08) 5-12 1274 1176 0.42 6-12 956 874 0.33 6-14 976 7-14 833 7-15 251 275 0.17 641 0.62 0 0.05 \ / B ......... 0 _ No.69577 (0� •, STATE OF J �. FGO RION.•' G=� �\ S/ONAL E0 COA #30003 / /III 1 I I I 0 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by W Component Solutions T 1. M."61 the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector e. r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "48" which indicates an.18 gauge plate, or •S# 18", which indicates a high tension 18 gauge plate. - CSBelp@strongtie. com EngDrwg: 2019r3RGT_ PS 100676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A15 Customer: Lu Dial SID: 0000940913 TID: 122969 Date: 03 / 09 / 21 Truss Mir. Contact: Rick Mills Page: 1 of 1 a-4-9 7-5-13 6-10-1 6-10-1 6-10-1 3-3-15 r-F 7-5-13 1 14-3-15 21-2-0 28-0-1 31-4-0 1 2 3 4 5 6 7 41-40 4x6 -5/12 5/12 3x4-- 3x63x4- 3x4i1 - 01 3x4- 0' H 4-1 4x4= 2x311 3x4= 3x6 4x6 3x4= 3x6 7-5-13 1 6-10-1 6-11-1 1 3-%15 , 1 1 %10-1 7-5-13 14-3-15 21-2-0 28-0-1 31-4-0 1 8 9 10 11 12 13 31-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead our Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 ps£ Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psi BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling.- No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt - 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf CSC End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013)• #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 1-3 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.12) 8- 9 BC 2x4 SP (ALSC6-2013) #2 1 03-14 1348 676 08-00 02-02 SPF 425 Vert DL L/120 L/999(-0.15) 8- 9 Webs 2x4 SP (ALSC6-2013) #2 13 31-02-04 1243 651 03-08 01-12 SPF 470 Vert CR L/240 L/999(-0.26) 8- 9 Max Horiz = -166 / +409 at Joint 1 Horz LL 0.75in ( 0.04) @Jtl3 Member Forces Summary Horz CR 1.25in ( 0.08) @Jtl3 . ..Mem... Ten comp .csl. Loads Summary Ohng CR 2L/240 2L/999( 0.01) 1- 1 TC OH- 1 35 0 0.19 1- 2 2085 2473 0.78 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 2- 3 1663 1830 0.73 live load occurring at [21-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 3- 4 1666 1694 1.00 factor. plus the creep component of deflection 4- 5 1204 1131 0.92 See LLoads a Report for loading combinations and additional details. due to dead load, computed as De£1_LL + 5- 6 1723 1692 0.84 Dead Loads may be slope adjusted: > 12.0/12 (Kcr - 1) x Defl DL in accordance with - 6- 7 723 692 0.84 ANSI/TPI 1. 7-OH 3 0 0.00 Bc 1- a 2206 2190 0.70 Notes Bracing Data Summary 8- 9 2206 2190 0.73 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ 9-10 1619 1495 0.64 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 10-11 1619 1495 0.67 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 11-12 627 615 0.51 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 4-11 12-13 0 0 0.32 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 13-OH 0 0 0.00 See BCSI-B3 3.0 Web 2- 8 268 0 0.06 2- 9 766 650 0.63 Plate offsets (X,1): 4- 9 481 256 0.16 (None unless indicated below) 4-11 940 881 0.33 Jntl(0,00-02) 5-11 477 400 0.55 6-11 461 307 0.44 6-12 964 808 0.51 7-13 1274 1225 0.47 \�\\\ M 8 O �1 No.69577 b• STATE OF �(/ F•LOR0 t� \_� ..,RV 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a •-18• which indicates an 18 gauge plate, or'S# 18-, which indicates a high tension 18 gauge plate. - CSHelp@strongtie.com EngDrwg: 2019r3RGT_Eng 60676 - Lobo - Paleo Pine Circle Oty: 1 Truss: Al Customer: Lu Dial SID: 0000940914 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 �-4-� 6-9-3 6-1-7 6-1-7 4-4-0 8-0-0 6-9-3 12_ _91 19-0-0 23-4-0 31-4-0 1 2 3 4 5 6 4x4= 4x6 -5/12 5/12 5x5o 3x6 `^ 3x4 1p ai � r o0 r� r� v 4-1 4x4= X 2x3n 3x4= 3x6 4x6 3x4= 3x6 6-9-3 6-1-7 6-1-7 4-4-0 8-0-0 6-9-3 12-1.0-9 19-0-0 23-4-0 31-4-0 1 7 8 9 10 11 12 r 31-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow 'Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 P1t 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 O.C. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0. Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) DSS 5-6 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.14) L1-12 BC 2x4 SP (ALSC6-2013) #2 1 03-14 1348 682 08-00 02-02 SPF 425 Vert DL L/120 L/999(-0.16) 11-12 Webs 2x4 SP (ALSC6-2013) #2 12 31-02-04 1243 651 03-08 01-12 SPF 470 Vert CR L/240 L/999(-0.30) 11-12 Max Horiz = -136 / +369 at Joint 1 Horz LL 0.75in ( 0.03) @Jtl2 Member Forces Summary Horz CR 1.25in ( 0.07) @Jtl2 ..Mem... Ten comp .CSI. Loads Summary Ohng CR 2L/240 2L/999( 0.02) 1- 1 TC OH- 1 35 0 0.26 1- 2 1575 2495 0.74 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 2- 3 1379 1956 0.68 live load occurring at [21-02-001 using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 3- 4 1137 1337 0.62 factor, plus the creep component of deflection 4- 5 1112 1159 0.73 due to dead load, computed as Defl_LL + See LLoads a Report for loading combinations and additional details. 5- 6 913 1080 0.00 (Kcr - 1) x Defl_DL in accordance with Dead Loads may be slope adjusted: > 12.0/12 ANSI/TPI 1. 6-OH 3 0 0.00 BC 1- 7 2231 1658 0.75 7- 8 2231 1658 0.69 Notes Bracing Data Summary 8- 9 1738 1207 0.61 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ 9-10 1738 1207 0.47 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 10-11 932 649 0.68 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 11-1.2 0 0 0.54 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 11- 6 12-OH 0 0 0.00 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd Web 2- 7 226 0 0.05 See BCSI-B3 3.0 2- 8 495 547 0.43 3- 8 436 150 0.10 Plate offsets (X, Y): 3-10 561 788 0.88 (None unless indicated below) 4-10 282 135 0.14 Jntl(0,00-02), Jnt3(-00-06,00-15) 5-10 524 329 0.48 5-11 464 407 0.44 6-11 1086 755 0.27 6-12 1147 1177 0.45 \ / M. soO�`''% ��/.• �1GENgE • ..�•� i No.69577 �r Z _ STATE OF " Cj11 T 'i PZORIQP•."' coAa 000ss��NAL0\� . 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates 0L Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18' which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. _ e t - CSHelp@strongtie. com EngDrwg: 2019r3RGT PS .00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A17 Customer: Lu Dial SID: 0000940915 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 -4-q 6-1- 5-567 0-0 F- 6-1 l I 15--507 241220 t 24-24-0 -9 -0 -0 -0 314-0 1 2 3 4 5 6 7 8 4x4= 3x4= 4x6 -5/12 5/12 3x4 r:��3x4u 3x6 2x3 i H N i v 4-1 4x4= J, 3x4= 3x6 4x6 4x8 3x6 8-9-14 8-2-2 8-4-0 6-0-0 8-9-14 17-0-0 25-4-0 31-4-0 1 9 10 11 12 13 11 31-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) - 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 7-8 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.22) 11-12 BC 2x4 SP (ALSC6-2013) #2 1 03-14 1348 682 08-00 02-02 SPF 425 Vert DL L/120 L/999(-0.17) 11-12 Webs 2x4 SP (ALSC6-2013) #2 13 31-02-04 1243 651 03-08 01-12 SPF 470 Vert CR L/240 L/937(-0.40) 11-12 Max Horiz -98 / +331 at Joint 1 Horz LL 0.75in ( 0.04) @Jtl3 Member Forces Summary Horz CR 1.25in ( 0.07) @Jtl3 ...Me.... Ten Comp .CSI. Loads Summary, ohng CR 2L/240 2L/999( 0.02) 1- 1 TC OR- 1 35 0 0.26 1- 2 1772 2503 0.78 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 2- 3 1631 2251 0.58 live load occurring at [21-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 3- 4 1638 2165 0.62 factor. plus the creep component of deflection 4- 5 1356 1544 0.57 due to dead load, computed as Defl_LL + See LLoads a Report for loading combinations and additional details. 5- 6 1009 1834 0.46 (Kcr - 1) x Defl DL in accordance with Dead Loads may be slope adjusted: > 12.0/12 - 1. 6- 7 1009 834 0.98 ANSI/TPI 7- 8 932 8-OH 3 966 0.79 0 0.00 Notes Bracing Data Summary BC 1- 9 2244 1850 0.87 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ 9-10 1838 1439 0.81 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 10-11 1838 1439 0.96 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 11-12 1166 978 0.89 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 6-12 12-13 0 0 0.68 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 13-OH 0 0 0.00 See SCSI-S3 3.0 Web 2- 9 415 297 0.08 4- 9 442 205 0.11 Plate offsets (X, Y). 4-11 518 647 0.58 (None unless indicated below) 5-11 334 190 0.16. Jntl(0,00-02) 6-11 451 164 0.20 6-12 639 639 0.21 7-12 216 77 0.06 8-13 1251 1201 0.46 \\��\�..•g 0QT,, No.69577 Q STATE OF C(/ FCORIOP.•' SIONAL COA#30003 1111II101 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates • Truss Studio V ® acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the 'Important Information &.General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a -48° which indicates an 18 gauge plate, or'S# 18', which indicates a high tension 18 gauge plate. n - CSHelp@strongtie. com Engi)-g: 2019r3RGT_Ps 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A18 Customer: Lu Dial SID: 0000940916 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 � -4-g 7-9-14 7-2-2 6-2-0 6-2-0 4-0-0 F� 7-9-14 i 15-0-0 21-2-0 27-4-0 31-4-0 1 2 3 4 5 6 7 -5/12 4x6 3x4= 4x6 5/12 3x4ii 3x6 3x4o A r v / 4-1 4x4= 2x3ii 4x6 3x6 3x4= 3x4= 3x6 7-9-14 7-2-2 6-2-0 6-2-0 4-0-0 7-9-14 15-0-0 21-2-0 27-4-0 31-4-0 1 J 8 9 10 11 12 13 J F 31-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC - 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location Sc 2x4 SP (ALSC6-2013) #2 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.13) 8- 9 Webs 2x4 SP (ALSC6-2013) #2 1 03-14 1348 682 08-00 02-02 SPF 425 Vert DL L/120 L/999(-0.16) 8- 9 13 31-02-04 1243 651 03-08 01-12 SPF 470 Vert CR ' L/240 L/999(-0.29) S- 9 Member Forces Summary Max Horiz = -60 / +311 at Joint 1 Horz LL 0.75in ( 0.04) @Jtl3 ...Mom... Ten Comp -CSI. Horz CR 1.25in ( 0.07) @Jtl3 TC OH- 1 35 0 0.26 Loads Summary Ohng CR 2L/240 2L/999( 0.02) 1- 1 1- 2 1823 2470 0.99 2- 3 1471 1763 0.93 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 3- 4 1491 1720 0.60 live load occurring at [21-02-00) using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 4- 5 1455 1542 0.92 factor. plus the creep component of deflection 5- 6 1426 1361 0.91 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + (Kcr - 1) x Defl_DL in accordance with 6- 7 758 751 0.53 Dead Loads may be slope adjusted: > 12.0/12 1. 7-OH 3 0 0.00 ANSI/TPI BC 1- 8 2203 1871 0.78 8- 9 2203 1871 0.74 Notes Bracing Data Summary 9-10 1361 1260 0.59 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------ Bracing Data ------------ 10-11 1361 1260 0.58 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 11-12 662 604 0.47 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 12-13 0 0 0.28 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 11- 6 13-OH 0 0 0.00 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd Web 2- 8 284 0 0.06 See SCSI-B3 3.0 2- 9 596 733 0.76 4- 9 354 122 0.08 Plate offsets (X, Y): 5- 9 366 172 0.23 (None unless indicated below) 5-11 726 561 0.39 Jntl(0,00-02) 6-11 978 943 0.33 6-12 804 709 0.48 7-13 1255 1218 0.46 \`\\\111a „ J.3 0 Tye, No.69577 _* * *_ Q STATE OF C(/\ F4OR10 GX� COA#30003V�ONAL 1;\\\\ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates ®. Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector �. aelpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. a - CSHelp@strongtie. coin EngDrwg: 2019r3RGT-PS ,00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A19 Customer: Lu Dial SID: 0000940917 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 6-9-14 6-2-2 5-5-5 5-5-5 1 5-5-5 6-9-14 F 1 1 13-0-0 18-5-5 23-10-11 12-0-0, 29-4-0 31-4-0 1 2 3 4 5 6 7 8 -5/12 4x6 3x6 3x4= 3x4= 4x4= 3x4n 5/<12 Z\1 X 4-1 4x4X 2x31I4x6 3x6 3x4= 4x8 3x6 6-9-14 6-2-2 8-2-0 8-2-0 2-0-0 , 6-9-14 F 1 1 1 13-0-0 21-2-0 29-4-0 31-4-0 1 J 9 10 11 12 13 14 J r 31-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B - 54.0 ft 200 lb SC Accessible Ceiling: No Total 40.40 Plt 1.25 1-60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt - 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.14) 10-12 2x4 SP (ALSC6-2013) #1 11-14 1 03-14 1348 682 08-00 02-02 SPF 425 Vert DL L/120 L/999(-0.18) 10-12 Webs 2x4 SP (ALSC6-2013) #2 14 31-02-04 1243 651 03-08 01-12 SPF 470 Vert CR L/240 L/999(-0.32) 10-12 Max Horiz = -22 / +311 at Joint 1 Horz LL 0.75in ( 0.04) @Jtl4 Member Forces Summary Horz CR 1.25in ( 0.08) @Jt14 ...Mem... Ten comp .csl. Ohng Loads Summary CR 2L/240 2L/999( 0.02) 1- 1 TC OH- 1 35 0 0.26 1- 2 1994 2500 0.84 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 2- 3 1709 1942 0.78 live load occurring at [21-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 3- 4 1643 1719 0.59 factor. plus the creep component of deflection 4- 5 1693 1719 0.73 5 due to dead load, computed as Defl_LL + See Loadcase Report for loading combinations and additional details. 1643 1719 0.73 5- (Kcr - 1) x Defl_DL in accordance with Dead Loads may be slope adjusted: > 12.0/12 1. 6- 7 441 390 0.58 ANSI/TPI 7- 8 413 434 0.20 8-OH 3 0 0.00 Notes Bracing Data Summary BC 1- 9 2238 2044 0.77 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------ Bracing Data ------------ 9-10 2238 2044 0.79 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 10-11 1700 1692 0.70 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 11-12 1700 1692 0.74 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 6-13 12-13 1278 1300 0.70 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 13-14 0 0 0.32 See BCSI-B3 3.0 14-OH 0 0 0.00 Web 2- 9 214 0 0.05 Plate offsets (X, l): 2-10 505 581 0.44 (None unless indicated below) 3-10 426 255 0.13 Jntl(0,00-02) 5-10 180 109 0.11 5-12 489 438 0.29 6-12 634 390 0.25 6-13 1308 1240 0.36 8-13 1139 1061 0.45 -. OO�/��� 8-14 1170 1269 0.48 `��\��\:•,.••• \ Gv'- .• �, j ��GEN$F i No.69577 _ Q STATE OF ,i� �� '• F�ORIOP.•'• COA#30003 //illlll\ 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates k Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Heipdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a •-18' which indicates an 18 gauge plate, or •S# 18', which indicates a high tension 18 gauge plate. - CSHelp@strongtia.com EngDc g: 2019r3RGT_PS 0676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A20 Customer: Lu Dial SID: 0000940918 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1-4-Q 5-9-14 5-2-2 6-9-5 6-9-5 I 6-9-5 -� 5-9-14 I 11-0-0 I 17-9-5 I 24-6-11 31-4-0 1 2 3 4 5 6 7 4x6 2x3ii 3x6 3x4= 3x8 ' S/12 <3x4�-- 4-1 4x4= 2x31I 3x4= 3x6 4x6 3x8 3x6 5-9-14 5-2-2 6-9-5 6-9-5 6-9-5 I 5-9-14 11-0-0 17-9-5 24-6-11 31-4-0 1 8 9 10 11 12 13 F 31-4-0 r Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Pit 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 3-5 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.13) 9-11 BC 2x4 SP (ALSC6-2013) #2 1 03-14 1348 681 08-00 02-02 SPF 425 Vert DL L/120 L/999(-0.18) 9-11 Webs 2x4 SP (ALSC6-2013) #2 13 31-02-04 1243 651 03-08 01-12 SPF 470 Vert CR L/240 L/999(-0.31) 9-11 Max Horiz = 0 / +311 at Joint 1 Horz LL 0.75in ( 0.04) @Jt13 Member Forces Summary Horz CR 1.25in ( 0.08) @Jtl3 . ..Mem... Ten comp .csl. Ohng Loads Summary CR 2L/240 2L/999( 0.02) 1- 1 TC OH- 1 35 1- 2 2325 0 0.26 2517 0.87 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 2- 3 2032 2112 0.71 live load occurring at [21-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 3- 4 1998 2074 0.73 factor. plus the creep component of deflection 4- 5 1998 2074 0.73 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + Defl_DL in accordance with 5- 6 1998 2074 0.83 Dead Loads may be slope adjusted: > 12.0/12 ANSI/TPI)lx 6- 7 1270 1460 0.73 7-OH 0 BC 1- 8 2259 0 0.00 2439 0.80 Notes Bracing Data Summary 8- 9 2259 2439 0.70 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ 9-10 1888 1962 0.64 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 10-11 1888 1962 0.66 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 11-12, 1460 1270 0.68 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 11- 6 12- 7 12-13 0 0 0.46 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd 13-OH 0 0 0.00 Less than 0.25/12 pitch requires adequate drainage to prevent ponding. See SCSI-B3 3.0 Web 2- 8 158 0 0.03 2- 9 527 413 0.22 Plate offsets (X,1): 3- 9 391 187 0.09 (None unless indicated below) 3-11 221 228 0.27 Tntl(0,00-02), Jnt7(-00-0B4O), 4-11 592 408 0.15 Jntl2(00-08,0) 6-11 841 881 0.27 7-12 1780 7-13 1074 1549 0.46 1187 0.44 \���\` \.. M • 6 OO //// / No.69577 _ STATE OF FGORO'.•' ////i`S/ON'Au COA #30003 1 1 1 1 I I I I 1\\\ 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of thisindividual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates. ® Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector , Helpdesk: 1-866-252-8606 s plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. n # - CSHelp@st=ngtie.com nngurwg: eui7r�n�'r_r 90676 - Lobo - Paleo Pine Circle Oty: 1 Truss: A21 Customer: Lu Dial SID: 0000940919 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Jl-4-Q 4-9-14 4-7-5-5 7-5-5 7-5-5 F� 4-9-14 1 9-0-02-2 1 16-5-5 23-10-11 1 31-4-0 1 2 3 4 5 6 7 ' 4x6 2x311 4x6 3x4= 3x8 5/12 1+111 2x3 i n v i 4x4= v 4-1 3x4= 3x6 4x6 3x8 3x6 9-0-0 7-5-5 7-5-5 1 7-5-5 9-0-0 I 1 16-5-5 23-10-11 31-4-0 1 J 8 9 10 11 12 J F 31-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead our Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft S - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #2 1-3 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.19) 8-10 BC 2x4 SP (ALSC6-2013) #2 1 03-14 1348 689 08-00 02-02 SPF 425 Vert DL L/120 L/999(-0.22) 8-10 Webs 2x4 SP (ALSC6-2013) #2 12 31-02-04 1243 644 03-08 01-12 SPF 470 Vert CR L/240 L/916(-0.40) 8-10 Max Horiz = 0 / +261 at Joint 1 Horz LL 0.75in ( 0.04) @Jtl2 Member Forces Summary Horz CR 1.25in ( 0.08) @Jtl2 . .Mem... Ten comp .csl. Ohng CR 2L/240 2L/999( 0.02) 1- 1 Loads Summary TC OH- 1 35 0 0.26 1- 2 2449 2532 0.96 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 2- 3 2163 2273 0.59 live load occurring at [20-02-00) using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 3- 4 2402 2580 0.86 factor. plus the creep component of deflection 4- 5 2402 2580 0.86 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + (Kcr - 1) x Defl_DL in accordance with 5- 6 2402 2580 0.72 Dead Loads may be slope adjusted: > 12.0/12 1. 6- 7 1604 1918 0.70 ANSI/TPI 7-OH 0 C 1- 8 2276 0 0.00 2490 0.88 Notes oes Bracing Data Summary 8- 9 2048 2082 0.86 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ 9-10 2048 2082 0.73 , Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 10-11 1918 1604 0.85 requirement to transfer unblocked diaphragm loads across those joints. ------- Web Bracing -- CLR----------- 11-12 0 0 0.56 Continuous Lateral Restraint (CLR) rows require diagonal bracing per Single: 10- 6 11- 7 12-OH 0 0 0.00 D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Continuous Restraint Bracing Req'd Web 2- 8 449 247 0.09 Less than 0.25/12 pitch requires adequate drainage to prevent ponding. See BCSI-B3 3.0 3- 8 365 80 0.08 3-10 589 415 0.51 Plate offsets (X, 1f): 4-10 622 445 0.11 (None unless indicated below) 6-10 893 895 0.28 Jntl(0,00-02), Jnt5(0,-00-04), 6-11 921 833 0.21 Jnt7(-00-08,0), Jntll(00-08,0) 7-11 2162 1808 0.55 7-12 1039 1181 0.30 _ No.69577 Q STATE OF0, ��ss/O � A' 1 , 4 vA / / COA #30003 / / 0 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building •Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. h - CSHelp@strongtie. corn tngurwg: zuivrJHGT_Ps 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: A22 Customer: Lu Dial SID: 0000940920 TID: 122969 Date: 03 / 09 ! 21 Truss Mfr. Contact: Rick Mills Page: 1 of 2 2-Ply 1-4-0 3-9-14 3-2-2 4-10-6 4-10-6 4-101 4-10-6 4-10-6 3-9-14 7-0-0 11-10-6 16-8-13 21-7-3 26-5-10 31-4-0 1 2 3 4 5 6 7 8 9 809 170# 170# 170# 170# 170# 170# 170# 170# 170# 170# 170# 170# 170# 3x4= 2x3II 3x4= 3x6 4x4= b 5x5= 5/12 4.8 3x4- N 4-1 3x8 o: 2x3n 3x4= 3x4= Sx7 4x6 4x4= SxS= 3x6 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 216# 3-9-14 3-2-2 4-10-6 4-10-6 4-10-6 4-10-6 4-10-6 3-9-14 7-0-0 11-10-6 16-8-13 21-7-3 26-5-10 31-4-0 1 10 11 12 13 14 15 16 17 31-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 2 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #1 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.31) 12-14 2x4 SP (ALSC6-2013) #2 13-17 1 03-14 2871 1693 08-00 02-04 SPF 425 Vert DL L/120 L/999(-0.33) 12-14 Webs 2x4 SP (ALSC6-2013) #2 17 31-02-04 3305 1991 03-08 02-05 SPF 470 Vert CR L/240 L/580(-0.64) 12-14 Other 2x4 SP (ALSC6-2013) #2 Max Horiz = 0 / +210 at Joint 1 Horz LL 0.75in ( 0.06) @Jtl7 Horz CR 1.25in ( 0.12) @Jtl7 Member Forces Summary Loads Summary Ohng CR 2L/240 2L/999 ( 0.01) 1- 1 ..Mem... Ten 35 Comp .CSI. 0 0.15 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and TC OH- 1 1- 2 3462 5877 0.52 live load occurring at [19-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 2- 3 3664 6127 0.46 factor. plus the creep component of deflection 3- 4 4731 7806 0.70 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + (Kcr - 1) x Defl_DL in accordance with 4- 5 5043 8360 0.70 Dead Loads ma be slo a adjusted: > 12.0/12 y p ANSI/TPI 1. 5- 6 5043 8360 0.70 Loads based on maximum and minimum reactions from tie-in spans 6- 7 4333 7195 0.63 Domain Max Min Location Dir Description Bracing Data Summary 7- 8 4333 8- 9 2669 7195 0.71 4439 0.57 Transfer loads: ---------- - TC 170 -162 7-00-12 Vert J17 @ -90 Deg --Bracing Data----------- 9-OH 0 0 0.00 TC 80 -75 7-01-08 Vert J3 @ -135 Deg Chords; continuous except where shown BC 1-10 5335 3279 0.77 TC 170 -162 9-00-12 Vert J17 @ -90 Deg Web Bracing -- None 10-11 5335 3279 0.69 TC 170 -162 11-00-12 Vert J17 @ -90 Deg 11-12 5605 3415 0.60 TC 170 -162 13-00-12 Vert J17 @ -90 Deg Plate offsets (X, Y): 12-13 7806 '4731 0.71 TC 170 -162 15-00-12 Vert J17 @ -90 Deg (None unless indicated below) 13-14 7806 4731 1.00 TC 170 -162 17-00-12 Vert J17 @. -90 Deg Jntl(00-02,0), Jntl3(0,00-12) 14-15 7195 4333 0.98 TC 170 -162 19-00-12 Vert J17 @ -90 Deg 15-16 4439 2669 0.67 TC 170 -162 21-00-12 Vert J17 @ -90 Deg 16-17 0 0 0.22 TC 170 -162 23-00-12 Vert J17 @ -90 Deg 17-OH 0 0 0.00 TC 170 -162 25-00-12 Vert J17 @ -90 Deg Web 2-10 237 2-11 320 317 0.02 331 0.03 TC 170 -162 27-00-12 Vert J17 @ -90 Deg r 3-11 326 98 0.05 TC 170 -162 29-00-12 Vert J17 @ -90 Deg @ -90 Deg \\ // 3-12 2524 1576 0.28 TC 170 -162 30-11-04 Vert J17 BC 83 3 7-00-12 Vert J17 @ -90 Deg \\ / 4-12 832 9-14 760 956 0.07 421 0.08 BC 283 -123 7-00-12 Vert J3 @ --90 Deg 9-00-12 Vert J17 @ -90 Deg \ \� .••"'-•., �T �j/ \ V (G '••or_ENSF' •• /� 5-19 655 738 0.05 BC 83 3 BC 83 3 11-00-12 Vert J17 @ -90 Deg •'� 6-14 1759 831 0.20 BC 83 3 13-00-12 Vert J17 @ -90 Deg �'••• 6-15 1052 1388 0.09 BC 83 3 15-00-12 Vert J17 @ -90 Deg No. 69577 8-15 3227 1947 0.36 BC 83 3 17-00-12 Vert J17 @ -90 Deg 8-16 1721 9-16 5241 9-17 2001 2458 0.15 3152 0.59 3145 0.18 BC 83 3 19-00-12 Vert J17 @ -90 Deg BC 83 3 21-00-12 Vert J17 @ -90 Deg BC 83 3 23-00-12 Vert J17 @ -90 Deg BC 83 3 25-00-12 Vert J17 @ -90 Deg �oi BC 83 3 27-00-12 Vert J17 @ -90 Deg STATE OFBC 83 3 29-00-12 Vert J17 @ -90 DegBC 83 3 30-11-04 Vert J17 @ -90 Deg� CORIDP.•'•G�=\ 2-PLY TRUSS Fastener Spacing �j\i A L NAL. Fasten each ply to the adjacent ply as follows(rows staggered): COA #30003//f!i llill 12.0" TC 2x4, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ o.c. BC 2x4, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. 3/9/2021 WE 2x4, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 9.0" o.c. NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. Al connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector n r . Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. CSHelp@strongtie. com 60676 - Lobo - Paleo Pine Circle oty: 1 Truss: A22 Customer: Lu Dial SID: 0000940§20 TID: 122969 Date: 03 / 09121 Truss Mfr. Contact: Rick Mills Page: 2 of 2 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. \`��1111111/j// \J��.•M. 80OT''% ENSF y� No.69577 Q STATE OF IJ,, •iT FZORVDPONAV- F 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates ® Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdeak: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a'•-18" which indicates an 18 gauge plate, ar "S# 18', which indicates a high tension 18 gauge plate. - CSHelp@strongtie. com cngurwg: �uisr.fe<�r cng 90676 - Lobo - Paleo Pine Circle Qty: 1 Truss: B1 Customer: Lu Dial SID: 0000940921 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 T-4-g 4-9-14 4-2-2 6-1-5 6-1-5 6-1-5 I 4-2-2 i 4-9-14 I I I 4-9-14 9-0-0 15-1-5 21-2-11 31-6-2 36-4-0 1 2 3 4 5 627-4-0 7 8 9 4x8 2x3ii 3x4=3x10-18 4x8 5/12 -5/12 2x3� 2x3-- 3x8 4-1 3x8 4-1 101 3x4= 4x6 4x6 4x6 3x4= 3x4= 9-0-0 6-1-5 6-1-5 6-1-5 9-0-0 9-0-0 15-1-5 21-2-11 27-4-0 36-4-0 1 10 11 12 13 14 15 9 36-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1-60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #1 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #2 6-7 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.32) 11-14 7-9 1 03-14 1541 801 08-00 02-07 SPF 425 Vert DL L/120 L/999(-0.34) 11-14 BC 2x4 SP (ALSC6-2013) #2 9 36-00-02 1450 735 08-00 02-04 SPF 425 Vert CR L/240 L/658(-0.65) 11-14 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz = -146 / +185 at Joint 1 Horz LL 0.75in ( 0.08) @Jt 9 Horz CR 1.25in ( 0.16) @Jt 9 Member Forces Summary Loads Summary Ohng CR 2L/240 2L/999 ( 0.01) 1- 1 ..Mem... Ten TC OH- 1 35 Comp .CSI. 0 0.19 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 1- 2 2712 2989 0.74 live load occurring at [18-02-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 2- 3 2474 2731 0.47 factor, plus the creep component of deflection 3- 4 3241 3293 0.72 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + Defl_DL in accordance with 4- 5 3241 3293 0.74 Dead Loads may be slope adjusted: > 12.0/12 ANSI/TPI)1x 5- 6 3293 3296 0.79 6- 7 3293 7- 8 2966 3296 0.91 65 0.96 Notes Bracing Data Summary g ry 8- 9 2966 3024 3029 0.96 Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ____________gracing Data ------------ BC 1-10 2693 2442 0.94 Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown 9-15 2732 2503 0.91 requirement to transfer unblocked diaphragm loads across those joints. Web Bracing -- None 10-11 2467 2100 0.83 11-12 3296 2948 0.78 Plate offsets (X, Y): 12-13 3296 2948 0.80 (None unless indicated below) 13-14 3296 2948 0.77 Jntl(00-02,0), Jnt9(-00-02,0), 14-15 2481 2089 0.84 Jntl2(0,00-04), Jntl3(0,00-04) Web 2-10 377 254 0.09 3-10 336 55 0.07 3-11 955 1078 0.98 4-11 567 356 0.10 5-11 315 320 0.28 5-14 578 7-14 943 7-15 343 354 0.10 1042 0.94 134 0.07 \\ ` M B O 0T 8-15 542 279 0.10 ......•.• \ (jV .•' •. y �� ��GENgF _ No.69577 �� � _ .- Q STATE OF �(/` FGORVDP' N NAL COA#30003/////illl1�\\\ 3/9/2021 NOTICE copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on,design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector rf r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a •-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - CSHelp@strongtie. com angurwg: cui�r�a _ ,00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: B2 Customer: Lu Dial SID: 0000940922 TID: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 2 2-Ply 2-1-112 4-55-10 45- 4 1 --4-0 4-0-4 I --0 4-0-4 70 1-11-3 I 4-10-6 �31 -01 1 2 3 4 5 6 7 8 9 10 11 - 80# 170# 170# 170# 170# 170# 170# # # 170# # 17b0# b3x4= b b 2x41 17b0# 17Q# 3x41 b b 18a45 5/12 Sx7 b bb SxS= 3x4b 7 _5/12 3x4- 3x4 m 4x6 � 4x8 4-1 4-1 X 2x4 3x4= 3x8 7x8= 7x16-18 3x8 3x4= 2x4 b b b b b b bb b b b b 4 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 83# 486# 216# 83# 83# 4-0-4 2-11-12 4-5-10 4-5-10 4-5-10 4-5-10 4-5-10 2-11-12 4-0-4 1 4-0-4 7-0-0 11-5-10 18-11-3 1 20-4-13 24-10-6 29-4-0 32-3-12 36-4-0 1 12 13 14 18 16 17 18 19 11 36-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) - 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 2 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) 42 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x6 SP (ALSC6-2013) #1 3-7 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.40) 15-16 7-9 1 04-00 3546 2110 08-00 02-13 SPF 425 Vert DL L/120 L/999(-0.41) 15-16 BC 2x6 SP (ALSC6-2013) #1 11 36-00-00 3700 2190 08-00 02-14 SPF 425 Vert CR L/240 L/530(-0.81) 15-16 Webs 2x4 SP (ALSC6-2013) #2 Max Horiz -97 / +140 at Joint 1 Horz LL 0.75in ( 0.08) @Jtll Horz CR 1.25in ( 0.15) @Jtll Member Forces Summary Loads Summary ohng CR 2L/240 2L/999 ( 0.01) 1- 1 ..Mem... Ten TC OH- 1 37 Comp .CSI. 0 0.15 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 1- 2 4548 7632 0.47 live load occurring at [18-02-00] using a 1.00 Full and 0-00 Reduced load horizontal deflections due to live load 2- 3 4832 8021 0.50 factor. plus the creep component of deflection 3- 4 6492 10670 0.37 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + (Kcr - 1) x De£l_DL in accordance with 4- 5 7605 12534 0.42 Dead Loads may be slope adjusted: > 12.0/12 ANSI/TPI 1. 5- 6 7605 12534 0.43 Loads based on maximum and minimum reactions from tie-in spans 6- 7 7699 7- 8 7699 12687 0.41 12687 0.42 Domain Max Min Location Dir Description Bracing Data Summary 8- 9 6744 11086 0.38 Transfer loads: TC 170 -162 7-00-12 Vert J17 @ -90 Deg ------------Bracing Data ------------ 9-10 5210 8656 0.54 TC 80 -75 7-01-08 Vert J3 @ -135 Deg Chords; continuous except where shown 10-11 4926 8251 0.50 TC 170 -162 9-00-12 Vert J17 @ -90 Deg Web Bracing -- None BC 1-12 6987 4126 0.65 TC 170 -162 11-00-12 Vert J17 @ -90 Deg 11-19 7557 4474 0.70 TC 170 -162 13-00-12 Vert J17 @ -90 Deg Plate offsets(X, Y): 12-13 6987 4126 0.65 TC 170 -162 15-00-12 Vert J17 @ -90 Deg (None unless indicated below) 13-14 7368 4329 0.51 TC 170 -162 17-00-12 Vert J17 @ -90 Deg Jnt3(00-03,-00-06), Jnt9(-00-03,-00-06), 14-15 10670 6336 0.72 TC 170 -162 19-00-12 Vert J17 @ -90 Deg Jntl4(-00-08,0), Jntl5(0,-02-00), 15-16 12723 7577 0.83 TC 170 -162 19-03-04 Vert J17 @ -90 Deg Jntl6(0,-02-00), Jntl7(00-08,0) 16-17 11086 6588 0.73 TC 170 -162 21-03-04 Vert J17 @ -90 Deg 17-18 7954 4678 0.55 TC 170 -162 23-03-04 Vert J17 @ -90 Deg 18-19 7557 4474 0.70 TC 170 -162 25-03-04 Vert J17 @ -90 Deg Web 2-12 331 2-13 455 472 0.03 392 0.05 TC 170 -162 27-03-04 Vert J17 @ -90 Deg \\\Illiif/J 3-13 496 137 0.05 TC 184 -168 29-02-08 TC 170 -162 29-03-04 Vert J3A @ -45 Deg Vert J17 @ -90 Deg \\ ` M • 80 3-14 3808 2339 0.43 BC 83 3 7-00-12 Vert J17 @ -90 Deg \\ \ \ ,.•• " '••., �T / \ \ /j 4-14 1244 4-15 2207 1688 0.11 1340 0.25 BC 216 -123 7-01-08 BC 83 3 9-00-12 Vert J3 @ -135 Deg Vert J17 @ -90 Deg \ \GEN$ �V F i 5-15 645 5-15 729 729 0.05 �•,••• 645 994 0.05 BC 83 3 11-00-12 BC 83 3 13-00-12 Vert J17 @ -90 Deg Vert J17 @ -90 Deg _ No. 69577 6-15 665 6-16 0.07 BC 83 3 15-00-12 Vert J17 @ -90 Deg 1661 • 8-17 1173 9-17 1173 1701 0.06 1569 0.10 21 1569 0.10 BC 83 3 17-00-12 BC 83 3 19-00-12 BC 83 3 19-03-04 Vert J17 @ -90 Deg Vert J17 @ -90 Deg Vert J17 @ -90 Deg 7C 9-18 734 243 0.08 BC 83 3 21-03-04 Vert J17 @ -90 Deg ��� �, 10-18 981 • 10-19 323 918 0.05 479 0.03 BC 83 3 23-03-04 BC 83 3 25-03-04 Vert J17 @ -90 Deg Vert J17 @ -90 Deg ••ir �� STATE OF �(/� BC 83 3 27-03-04 Vert J17 @ -90 Deg i/�,(\•'•, F�QRt0P ,••���; BC 486 -244 29-02-08 3 29-03-09 Vert J3A @ -95 Deg -90 i `` 0 •........ / SSl BC 83 Vert J17 @ Deg \\\ 1Y~L \ \\\\\ COA#30003/ 00 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V ® acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional Information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector r Belpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a •-18• which indicates an 18 gauge plate, or "S# 18, which indicates a high tension 18 gauge plate. n 4 - CSHelp@strongtie-.corn EngDrwg: 2019r3RGT-Eng 60676 - Lobo - Paleo Pine Circle Qty: 1 Truss: B2 Customer: Lu Dial SID: 0000940922 TID: 122969 Date: 03 / 09121 Truss Mfr. Contact: Rick Mills Page: 2 of 2 2-PLY TRUSS Fastener Spacing fasten each ply to the adjacent ply as follows(rows staggered): TC 2x4, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. TC 2x6, 2-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. BC 2x6, 2-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. WB 2.4, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 9.011 o.c. Notes Plates designed for Cq at 0..80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. \`�IIIIIIIJ//1/ i No.69577 N— � • o� • STATE OF �(/� �COR10P. ONAI. COA#300031//JJIIII�1��\ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates • Truss Studio V ® acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector n ` r Heipdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a •-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - CSHelp@strongt:ie.com Engl) wg: 2019r3RGT_Eng .00676 - Lobo - Paleo Pine Circle Qty: 4 Truss: C1 Customer: Lu Dial SID: 0000940923 TID: 122169 Date: 03 10 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 u, 4-1 X , -4-Q 6-1-14 1 5-6-2 I 5-6-2 I 5-8-6 6-1-14 11-8-0 17-2-2 22-10-8 1 2 3 4 5 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Wedge 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 35 0 0.26 1- 2 1541 1729 0.76 2- 3 1595 1620 0.77 3- 4 1690 1583 0.77 4- 5 1635 1678 0.77 BC 1- 6 1533 1325 0.86 5- 8 1492 1337 0.80 6- 7 1001 733 0.76 7- 8 1001 733 0.71 Web 2- 6 541 309 0.09 3- 6 638 589 0.48 3- 8 600 654 0.53 4- 8 573 287 0.10 3x6 7-0-0 1 9-4-0 6-6-8 7-0-0 16-4-0 22-10-8 22-10-8 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) - 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs) ---------------- Jot --X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 1011 533 08-00 01-09 SPF 425 5 22-08-12 903 457 03-08 01-05 SPF 470 Max Horiz = -186 / +230 at Joint 1 Loads Summary m '-i 6-6 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.21) 6- 8 Vert DL L/120 L/999(-0.26) 6- 8 Vert CR L/240 L/575(-0.47) 6- 8 Horz LL 0.75in ( 0.02) @Jt 5 Horz CR 1.25in ( 0.05) @it 5 Ohng CR 2L/240 2L/999( 0.02) 1- 1 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and live load occurring at [11-08-001 using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load factor. plus the creep component of deflection See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + Dead Loads may be slope adjusted: > 12.0/12 (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Notes Bracing Data Summary Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees ------------Bracing Data ------------ Plates located at TC pitch breaks meet the prescriptive minimum size Chords; continuous except where shown requirement to transfer unblocked diaphragm loads across those joints. Web Bracing -- None No.69577 _ STATE OF F40RIOP- sS�ONAL E\G �\ COA#30003 11/111110 3/9/2021 Plate offsets (X, l): (None unless indicated below) Jnt5(-03-10,01-01) NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates , Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a'-l8' which indicates an 18 gauge plate, or'S# 18°, which indicates a high tension 18 gauge plate. H r - - CSHelp@strongtie.com EngDr g: LU19rJRGT SPS 80676 - Lobo - Paleo Pine Circle Qty.- 1 Truss: C2 Customer: Lu Dial SID: 0000940924 TID: 122969 Date: 03/08/21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 A v 4-1 X -4-Q 5-9-14 5-2-2 1-4-0 5-2-2 5-4-6 F ' 5-9-14 1 11-0-0 112-4-01 17-6-2 I 22-10-8 1 2 3 4 5 6 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Wedge 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 35 0 0.26 1- 2 1297 1726 0.64 2- 3 1068 1255 0.59 3- 4 1050 1095 0.31 4- 5 1075 1253 0.61 5- 6 1460 1667 0.67 BC 1- 7 1534 1135 0.53 6-11 1487 1184 0.52 7- 8 1534 1135 0.46 8- 9 1095 672 0.43 9-10 1095 672 0.45 10-11 1487 1184 0.47 Web 2- 7 198 0 0.04 2- 8 514 550 0.25 3- 8 288 189 0.06 4-10 282 219 0.08 5-10 637 493 0.26 5-11 172 0 0.04 4x4= 4x4= 5-9-14 5-2-2 11-4-0 l 5-2-2 5-9-14 11-0-0 lz-a-o 17-6-2 7 8 40 22-10-8 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No 22-10-8 11 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) - 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B = 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R =1Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction SumaryiLbs) ---------------- Jnt --X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 1011 533 08-00 01-09 SPF 425 6 22-08-12 903 457 03-08 01-05 SPF 470 Max Horiz = -178 / +222 at Joint 1 Loads Summary 6-6 1 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.09) 7- 8 Vert DL L/120 L/999(-0.09) 7- 8 Vert CR L/240 L/999(-0.18) 7- 8 Horz LL 0.75in ( 0.03) @Jt 6 Horz CR 1.25in ( 0.05) @Jt 6 Cling CR 2L/240 2L/999( 0.02) 1- 1 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and live load occurring at (11-08-00] using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load factor. plus the creep component of deflection See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + Dead Loads may be slope adjusted: > 12.0/12 (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. M BOO;''', No. 69577 STATE COA #30003/ / / III I I I 1 \ \ 3/9/2021 Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X,1): (None unless indicated below) Jnt6(-03-10,01-01) NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by ® Component Solutions ng ind the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawiicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and 'the 'Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a ° 18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. N 4 - o CSHelp@strongtie. corn rngu g: zulYrj.vr es 80676 - Lobo - Paleo Pine Circle City: 1 Truss:.C3 Customer: Lu Dial SID: 0000940925 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 rd 1-4 -q 4-9-14 I 1 I 4-2-2 5-4-0 4-2-2 4-9-14 91-4-Q 4-9-14 9-0-0 14-4-0 18-6-2 23-4-0 4x6 4x6 9-0-0 I 5-4-0 I 9-0-0 9-0-0 14-4-0 23-4-0 L 7 8 9 6 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 35 0 0.26 1- 2 1594 1744 0.70 2- 3 1327 1456 0.37 3- 4 1287 1297 0.69 4- 5 1328 1458 0.39 5- 6 1593 1743 0.70 6-OH 35 0 0.26 BC 1- 7 1558 1382 0.65 6- 9 1557 1228 0.66 7- 8 1296 966 0.62 8- 9 1296 966 0.63 Web 2- 7 421 306 0.11 3- 7 329 75 0.07 4- 7 154 152 0.13 4- 9 329 95 0.07 5- 9 418 296 0.11 23-4-0 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No -. Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS CSC End Zone: 5-04-13 Reaction Summary --------------Reaction SummaryjLbs) ---------------- Jnt --X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 1018 536 08-00 01-10 SPF 425 6 23-00-02 1018 536 08-00 01-10 SPF 425 Max Horiz = -166 / +166 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [11-08-001 using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. \\11111111///// No. 69577 Ir c.- Q� . STATE"OF g �i '•.FGORIOP.•'�G�=� COA #30003 / / 1 / 1111100 \ 3/9/2021 4-1 Z -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.14) 1- 7 Vert DL L/120 L/999(-0.15) 1- 7 Vert CR L/240 L/963(-0.28) 1- 7 Horz LL 0.75in ( 0.03) GJt 6 Horz CR 1.25in ( 0.06) @Jt 6 ohng CR 2L/240 2L/999( 0.02) 1- 1 ohng CR 2L/240 2L/999( 0.02) 6- 6 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl-LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, l): (None unless indicated below) NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates ® Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information &General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762: All connector Helpdesk: 1-866-252-.8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. a CsHelp@strongtie.com EngDrwg: 2019r3RG7_PS 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: C4 Customer: Lu Dial SID: 0000940926 TID: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1-4-0 3-9-14 1 3-2-2 4-8-0 4-8-0 3-2-2 3-9-14 1-4-0 3-9-14 7-0-0 11-8-0 16-4-0 19-6-2 23-4-0 1 2 3 4 5 6 7 80# 170# 170# 80# 170# 170# 170# 170# w 2x311 �4x8 5/12 4x8� -5/12 2x3 2x3 r-I � n M - � 5x7 5x7 4-1 4-1 r^ 3x4= 4x8 3x10-18 3x4= 216# 83# 83# 83# 83# 216# 83# 83# 7-0-0 I 4-8-0 4-8-0 1 7-0-0 1 1 7-0-0 11-8-0 16-4-0 23-4-0 J 8 9 11 7 J F 23-4-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Pit 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS ' OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 3-5 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.24) 8- 9 BC 2x4 SP (ALSC6-2013) #1 1 04-00 2073 1227 08-00 03-04 SPF 425 Vert DL L/120 L/999(-0.26) 9-11 Webs 2x4 SP (ALSC6-2013) #2 7 23-00-00 2073 1227 08-00 03-04 SPF 425 Vert CR L/240 L/543(-0.50) 9-11 Wedge 2x4 SP (ALSC6-2013) #2 Max Horiz = -128 / +128 at Joint 1 Horz LL 0.75in ( 0.06) @Jt 7 Horz CR 1.25in ( 0.12) @Jt 7 Member Forces Summary Loads Summary Ohng CR 2L/240 2L/999 ( 0.02) 1- 1 ..Mem... Ten Comp .CSI. Ohng CR 2L/240 2L/999( 0.02) 7- 7 TC OH- 1 35 0 0.29 This truss has been designed for the effects of an unbalanced top chord 1- 2 2517 4186 0.82 live load occurring at [11-08-00] using a 1.00 Full and 0.00 Reduced load Vert CR and Horz CR are the vertical and 2- 3 2499 4150 0.69 factor. horizontal deflections due to live load 3- 4 2929 4713 0.77 See Loadcase Report for loading combinations and additional details. plus the creep component of deflection 4- 5 2929 4713 0.77 Dead Loads may be slope adjusted: > 12.0/12 due to dead load, computed as Defl_LL + 5- 6 2499 4150 0.69 Loads based on maximum and minimum reactions from tie-in spans (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. 6- 7 2517 4186 0.82 Domain Max Min Location Dir Description 7-OH 35 0 0.29 BC 1- 8 3779 2185 0.77 Transfer loads: Bracing Data Summary 7-11 3779 2185 0.77 TC 170 -162 7-00-12 Vert J17 @ -90 Deg TC 80 -75 7-00-12 Vert J3 @ -135 Deg ------------Bracing Data ------------ 8- 9 3794 2142 0.88 TC 170 -162 9-00-12 Vert J17 @ -90 Deg Chords; continuous except where shown 9-10 3794 2142 0.85 TC 170 -162 11-00-12 Vert J17 @ -90 Deg Web Bracing -- None 10-11 3794 2142 0.88 TC 170 -162 12-03-04 Vert J17 @ -90 Deg Web 2- 8 335 195 0.06 TC 170 -162 14-03-04 Vert J17 @ -90 Deg Plate offsets (X,l): 3- 8 304 61 0.09 TC 170 -162 16-03-04 Vert J17 @ -90 Deg (None unless indicated below) 3- 9 1121 725 0.38 TC 80 -75 16-03-04 Vert J3 @ -45 Deg Jntl(04-14,01-08), Jnt7(-04-14,01-08) 4- 9 696 698 0.12 BC 216 -123 7-00-12 Vert J3 @ -135 Deg 5- 9 1121 725 0.38 BC 83 3 7-00-12 Vert J17 @ -90 Deg 5-11 304 61 0.09 BC 83 3 9-00-12 Vert J17 @ -90 Deg 6-11 337 196 0.06 BC 83 3 11-00-12 Vert J17 @ -90 Deg BC 83 3 12-03-04 Vert J17 @ -90 Deg BC 83 3 14-03-04 Vert J17 @ -90 Deg BC 216 -123 16-03-04 Vert J3 @ -45 Deg \ / \ BC 83 3 16-03-04 Vert J17 @ -90 Deg\` J��. • • • •'B�OT�'% Notes ,. GENS�c .�,• (� Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size _ No. 69577 •� • requirement to transfer unblocked diaphragm loads across those joints. = 1 1 �Q STATE OF L(� 'c40RIO ' GN' • SNAL COA #30003 11 1 1 1 1 1\\ 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates 0 Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector aelpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. A f - CSBelp@strongtie. com EngDrwg: 2019r3RGT_Eng 60676 - Lobo - Paleo Pine Circle City: 1 Truss: D1 Customer: Lu Dial SID: 0000940927 TID: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-Ply Ep 1-4-0 3-0-0 2-0-12 2-0-12 2-6-8 3-0-0 3-0-0 5-0-12 7-1-8 9-8-0 12-8-0 1 2 3 4 5 6 # -5t # - 5/12 -58# -58# t 30# -5/12 . 4x4= t 2x3" 4x8 4x10 4x6 4-1 N4x84-1 X2x3n 4x4= 7x8= 3 21# 21# 21# 21# 1374# 1380# 33# 3499# 33# 21# 3-0-0 1 2-0-12 1 2-0-12 2-6-8 i 3-0-0 3-0-0 5-0-12 7-1-8 9-8-0 12-8-0 1 7 8 9 10 6 J 12-8-0 J Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 O.C. Plies: 2 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location 2x4 SP (ALSC6-2013) #1 2-5 Jot--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/822(-0.18) 8- 9 BC 2x6 SP (ALSC6-2013) DSS 1 04-00 2770 1594 08-00 02-03 SPF 425 Vert DL L/120 L/795(-0.18) 8- 9 Webs 2x4 SP (ALSC6-2013) #2 6 12-04-00 4845 2648 08-00 03-13 SPF 425 Vert CR L/240 L/404(-0.36) 8- 9 Max Horiz = -26 / +70 at Joint 1 Horz LL 0.75in ( 0.02) @Jt 6 Member Forces Summary Horz CR 1.25in ( 0.04) @Jt 6 ...Mem... Ten Comp .CSI. Loads Summary Ohng CR 2L/240 2L/999( 0.01) 1- 1 TC OH- 1 37 0 0.15 1- 2 3362 5879 0.45 This truss has been designed for the effects of an unbalanced top chord Vert CR and Horz CR are the vertical and 2- 3 4829 8360 0.47 live load occurring at [6-04-00) using a 1.00 Full and 0.00 Reduced load horizontal deflections due to live load 3- 4 6475 11294 0.87 factor. plus the creep component of deflection 4- 5 6475 11294 0.79 See Loadcase Report for loading combinations and additional details. due to dead load, computed as Defl_LL + (Kcr - 1) x Defl_DL in accordance with 5- 6 5364 9636 0.65 Dead Loads may be slope adjusted: > 12.0/12 ANSI/TPI 1. BC 1- 7 5331 3018 0.19 Loads based on maximum and minimum reactions from tie-in spans 6-10 8814 4872 0.39 7- 8 5303 3006 0.41 Domain Max Min Location Dir Description Bracing Data Summary 8- 9 8360 4761 0.65 Transfer loads: TC 57 -58 3-00-12 Vert J13 @ 90 Deg ------------Bracing Data ------------ 9-10 8657 4794 0.66 TC 30 -23 3-01-08 Vert J3D @ 135 Deg Chords; continuous except where shown Web 2- 7 423 166 0.04 TC 57 -58 5-00-12 Vert J13 @ 90 Deg Web Bracing -- None 2- 8 3390 1974 0.38 TC 57 -58 6-04-00 Vert J13 @ 90 Deg 3- 8 975 1588 0.08 TC 57 -58 7-07-04 Vert J13 @ 90 Deg Plate offsets(X, Y): 3- 9 3520 1924 0.39 TC 30 -23 9-06-08 Vert J3D @ 45 Deg (None unless indicated below) 4- 9 372 162 0.03 TC 57 -58 9-07-04 Vert J13 @ 90 Deg Jnt5(00-10,-00-04), Jnt9(0,-01-00), 5- 9 2832 1770 0.32 BC 21 11 3-00-12 Vert J13 @ 90 Deg JntlO(0,-01-09) 5-10 2211 1100 0.25 BC 33 -30 3-01-08 Vert J31) @ 135 Deg BC 21 11 5-00-12 Vert J13 @ 90 Deg BC 21 11 6-04-00 Vert J13 @ 90 Deg BC 3499 -2096 7-01-08 Vert Al @ -90 Deg BC 21 11 7-07-04 Vert 3 @ 90 Deg BC 1374 -684 9-00-112 Vert A2@-90 Deg BC 33 -30 9-06-08 Vert J3D @ 45 Deg \•. M BC 21 11 9-07-04 Vert J13 @ 90 Deg \\\\ \ .........�� BC 1380 -682 11-00-12 Vert A3 @ -90 Deg ''�\%rENSF ''•-/y j 4j,� , i 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): No. 69577 TC 2x4, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c. BC 2x6, 2-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 12.0" o.c.** WB 2x4, 1-row(s) of 10d Nails (0.120" dia. x 2-7/8" min.) @ 9.0" o.c. ** Use additional fasteners of the same type within +/-12" of the _ 1 _ 7i /y Ll �" w location(s) indicated (except where approved hangers are used with fasteners that transfer the load to all plies) : • Q'• $T,4TE OF �` BC:7-04-06, 17, BC:9-04-13, 5, BC:11-00-12, 5 'i �� •'•. F<ORIOP.•'• Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees COA #30003 Plates located at TC pitch breaks meet the prescriptive minimum size 31912021 requirement to transfer unblocked diaphragm loads across those joints. NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General _ 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a •-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. = CSHelp@strongtie.com EngDrwg: 2019r3RGT_Eng 00676 - Lobo - Paleo Pine Circle City: 1 Truss: E1 Customer: Lu Dial SID: 0000940928 TID: 122969 Date: 03 108 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 $1-4-04, 2-7-0 2-0-0 2-0-0 1 2-0-0 2-0-0 2-7-0 11-4-0 6-7-0 I 13-2-0 1 1 2 3 4 5 6 7 0 rn 4-1 ON Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow Be 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: �1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 Be 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 4 35 0 0.26 4- 7 35 0 0.26 Be 1- 7 208 51 0.13 Web 2- 8 258 107 0.04 3- 9 255 132 0.04 4-10 77 115 0.02 5-11 255 132 0.04 6-12 257 107 0.04 5/12 3x4= -5/12 Typical plate: 2x3 2-7-0 { 2-0-0', 2-0-0 1 2-0-0 12-0-0 12-7-0 13-2-0 1 8 9 10 11 12 7 13-2-0 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L•- 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 Be = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 7 92 50 13-02-00 Max Horiz = -115 / +115 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [6-07-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Gable webs are attached with min. lx3 20 ga.plates. The max.rake overhang - 1/2 the truss spacing. If this truss is exposed to wind loads perpendicular to the plane of the truss, it must be braced according to a standard detail matching the wind criteria shown, or according to the Construction Documents and/or BCSI - B3. Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. � �k/.• ��GENSF • • �,� � No. 69577 XZ �• �� STATE OF '�SS��NAL COA#3DO03 I/IIIIIII 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf Be Limited Storage: Yes 200 lb Be Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 1- 8 Vert DL L/120 L/999( 0.00) 12- 7 Vert CR L/240 L/999(-0.00) 12- 7 Horz LL 0.75in ( 0.01) @Jt 7 Horz CR 1.25in ( 0.01) @Jt 7 Ohng CR 2L/240 2L/999( 0.02) 1- 1 Ohng CR 2L/240 2L/999( 0.02) 7- 7 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, 1): (None unless indicated below) NOTICE A copy of this design shall be furnished to the erection contractor. The design of thistridividual truss is based on design criteria and requirements supplied by Component E"I ons the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates � Truss studacceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & GeneralNotes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762.All connector Helpdesk: 66-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. ~ N ` CSHelp@strongtie. corn EngDrwq: @0676 - Lobo - Paleo Pine Circle Oty: 1 Truss: E2 Customer: Lu Dial SID: 0000940929 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 6-7-0 6-7-0 �1-4-0 F 6-7-0 I 13-2-0 1 ra Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 35 0 0.26 1- 2 780 726 0.72 2- 3 780 726 0.72 3-OH 35 0 0.26 BC 1- 4 606 503 0.48 3- 4 606 503 0.48 Web 2- 4 271 0 0.06 5/12 4x4o -5/12 6-7-0 6-7-0 13-2-0 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No 6-7-0 13-2-0 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B = 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 612 330 08-00 00-15 SPF 425 3 12-10-02 612 330 08-00 00-15 SPF 425 Max Horiz = -115 / +115 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [6-07-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. ��� M B�OT�'% �4 LICENSE' No. 69577 Q STATE OF �(/\ �40R10P.•' �ONAU ECG �\ COA#30003�/11111111t��\ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.03) 1- 4 Vert DL L/120 L/999(-0.04) 1- 4 Vert CR L/240 L/999(-0.07) 1- 4 Horz LL 0.75in ( 0-01) @Jt 1 Horz CR 1.25in ( 0.01) @Jt 1 Ohng CR 2L/240 2L/999( 0.02) 1- 1 Ohng CR 2L/240 2L/999( 0.021 3- 3 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, l): (None unless indicated below) Jnt2(0,00-15) ®Component Solutions Truss Studio V 2020.1.2.1 r Helpdesk: 1-866-252-8606 CSHelp@strongtie.com EngDrwq: 60676 - Lobo - Paleo Pine Circle Qty: 1 Truss: E3 Customer: Lu Dial SID: 0000940930 TID: 122969 Date: 03 108 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 H Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet. Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem.... Ten Comp .CSI. TC 1- 2 949 769 0.83 2- 3 949 769 0.83 BC 1- 4 649 705 0.50 3- 4 649 705 0.50 Web 2- 4 278 23 0.06 6-7-0 I 6-7-0 6-7-0 13-2-0 L 2 3 5/12 3x8 -5/12 6-7-0 6-7-0 6-7-0 13-2-0 L 4 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No 13-2-0 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L - 63.7 ft B = 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs) ---------------- int --X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 526 268 08-00 00-13 SPF 425 3 12-10-02 526 268 08-00 00-13 SPF 425 Max Horiz = -114 / +114 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [6-07-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. No.69577 _ �V ZZ STATE OF �(r T i F40R1ON.•' COA# 0003ZONALW\\�\ 3/9/2021 4-1 Z -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.04) 1- 4 Vert DL L/120 L/999(-0.04) 1- 4 Vert CR L/240 L/999(-0.08) 1- 4 Horz LL 0.75in ( 0.02) @Jt 1 Horz CR 1.25in ( 0.02) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, l): (None unless indicated below) NOTICE copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector n r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or'S# 18", which indicates a high tension 18 gauge plate. - . CSHelp@strongtie. corn EngDrwg: 2019r3RGT PS 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: VIIA Customer: Lu Dial SID: 0000940931 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 4-6-8 4-0-0 4-6-8 8-6-8 1 2 3 2x3ii 5/12 2x3ii 3x4l-�-- Code/Design: FSC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.25 1.60 N/A Total 31.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 123 512 0.48 2- 3 69 228 0.48 3-OH 0 3 0.00 BC 1- 4 134 103 0.14 4- 5 134 103 0.05 5- 6 134 103 0.02 6- 7 134 103 0.02 7-OH 0 0 0.00 Web 2- 5 756 254 0.13 3- 7 330 101 0.29 4-6-8 I 4-0-0 4-6-8 8-6-8 1 4 5 6 7 8-6-8 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 1.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 5 4-06-08 257 254 8-06-08 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 7 31 18 8-06-08 (reduced) Max Horiz = -118 / +234 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at 18-06-081 using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Valley Truss application only Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the 'prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. `\111111111//// _ No.69577 X ~ - Q STATE OF �(/ ` i� '.40R1ON oiva� COA#30003//IiiIIII1�,\\ 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 6- 7 Vert DL L/120 L/999(-0.00) 6- 7 Vert CR L/240 L/999(-0.00) 6- 7 Horz LL 0.75in ( 0.00) @Jt 1 Horz CR 1.25in ( 0.00) @it 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, l): (None unless indicated below) NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General Notes" page for additional information. All connector plates shall. be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or'S# 18", which indicates a high tension 18 gauge plate. ®Component Solutions Truss Studio V 2020.1.2.1 Helpdesk: 1-866-252-8606 Y CSHelp@strongtie.com EngDrwg: 1.00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: V1 B Customer: Lu Dial SID: 0000940932 TID: 122969 Date: 03 ! IS / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.25 1.60 N/A Total 31.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x6 SP (ALSC6-2013) #2 2x4 SP (ALSC6-2013) #2 6-3 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 30 130 0.14 2- 3 3 2 0.61 3-OH 0 0 0.00 BC 1- 4 3 2 0.22 4- 5 3 2 0.22 5- 6 3 2 0.08 6-OH 0 0 0.00' Web 2- 4 337 107 0.04 3- 6 394 120 0.07 1-10-8 I 4-2-8 1-10-8 6-1-0 1 2 5/12 3x8pm 3x6pm 9-6 3x4- 2x3pmii 1-10-8 4-2-8 1-10-8 6-1-0 1 4 5 6-1-0 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B = 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 1.0 End Vertical Exposed: L = Yes R =Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (pl£) ----- Jnt-Jnt React -Up- --Width- 1- 6 61 49 6-01-00 Max Horiz = 0 / +24 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at 13-11-12] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Valley Truss application only Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. A "pm" next to the plate size indicates that the plate has been user modified; see Plate Offsets for any special positioning requirements. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. \\tttllllll//// M. 130 No.69577 -_ STATE OF ,,cuss •........•��c,�. COA #30003 /ON111 AL `; `\\\ 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 4- 5 Vert DL L/120 L/999(-0.00) 4- 5 Vert CR L/240 L/999(-0.01) 4- 5 Horz LL 0.75in ( 0.00) @Jt 1 Horz CR 1.25in ( 0.00) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, l): (None unless indicated below) Jnt2(-01-10,00-04), Jnt3(-00-03,-01-01), Jnt4(01-03,-00-01), Tnt6(-00-03,01-05) NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by ® Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18% which indicates a high tension 18 gauge plate. n + - CSHelp@strongtie. cam EngDr g: 2019r3RGT_PS 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: V1E Customer: Lu Dial SID: 0000940933 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.25 1.60 N/A Total 31.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 256 113 0.29 2- 3 231 113 0.29 BC 1- 4 71 112 0.13 3- 6 71 112 0.12 4- 5 71 112 0.03 5- 6 71 112 0.03 Web 2- 5 282 132 0.05 4-7-0 i 4-7-0 4-7-0 9-2-0 5/12 3x4= -5/12 Ln 0 3x4l-: 3x4� 4-7-0 4-7-0 4 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No 2x3ii 4-7-0 9-2-0 6 9-2-0 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC - 1.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 1 1-00-12 195 159 9-02-00 3 B-01-04 195 159 9-02-00 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 3 19 14 9-02-00 (reduced) Max Horiz = -61 / +61 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [4-07-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 1- 4 Vert DL L/120 L/999(-0.00) 1- 4 Vert CR L/240 L/999(-0.00) 1- 4 Horz LL 0.751n ( 0.00) @Jt 1 Horz CR 1.25in ( 0.00) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------ Bracing'Data------------ Chords; continuous except where shown Web Bracing -- None Notes Plate offsets (X,1): Valley Truss application only (None unless indicated below) Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. �GENg y No. 69577 - �. LL �' STATE OF ;;��(�� F/�T F<OR XoN S�ONAL COA#30003 1/1III11�� 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates ETruss Studio V , acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. At connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector n , Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - a CSHelp@strongtie. com cngu g: Zu15raacx r5 a0676 - Lobo - Paleo Pine Circle City: 1 Truss: V2A Customer: Lu Dial SID: 0000940934 TID: 122969 Date: 03 / 08 / 21 Truss Mir. Contact: Rick Mills Page: 1 of 1 6-6-8 6-6-8 1 2 5/12 2x4 . I 3x41-r- N 2x4 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 1.0 1. 1.25 1.60 N/A Total 31.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 50 268 0.86 2-OH 0 3 0.00 BC 1- 3 101 76 0.82 3- 4 101 76 0.36 4- 5 101 76 0.07 5-OH 0 0 0.00 Web 2- 5 507 140 0.21 6-6-8 6-6-8 1 3 4 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition:' All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L - 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 1.0 End Vertical Exposed: L = Yes R - Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 3 2-08-00 164 162 6-06-08 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 5 36 24 6-06-08 (reduced) Max Horiz = -85 / +170 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [6-06-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Valley Truss application only Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. \,\GEN3F No. 69577 STATE OF �(/\ .FL0R1ON COA # 0003V 1NAL 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 1b TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.01) 1- 3 Vert DL L/120 L/999(-0.00) 1- 3 Vert CR L/240 L/999(-0.01) 1- 3 Horz LL 0.75in ( 0.02) @Jt 1 Horz CR 1.25in ( 0.03) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X,1t): (None unless indicated below) Jnt2(0,00-11), Jnt5(0,-00-10) ®Component Solutions Truss Studio V 2020.1.2.1 a'Helpdesk: 1-866-252-8606 CSHelp@strongtie.com NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specked plate size is followed by a "48" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. ang-g: zuiyr�xus_rs ,00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: V2B Customer: Lu Dial SID: 0000940935 TID: 122969 Date: 03 / 08 ! 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1-10-8 I 2-2-8 F 1-10-8 4-1-0 1 2 3 5112 3x8pm 3x6pm 9-6 3x4o 2x3pmu 1-10-8 2-2-8 1-10-8 4-1-0 1 4 5 J J F 4-1-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead our Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 1.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 31.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(l.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 1.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf CSC End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 Reactions not shown: down < 400 and up < 150 TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 ---- Reaction Summary (plf) ----- Vert LL L/360 L/999(-0.00) 4- 5 Webs 2x6 SP (ALSC6-2013) #2 Jnt-Jnt React -Up- --Width- Vert DL L/120 L/999(-0.00) 4- 5 2x4 SP (ALSC6-2013) #2 5-3 1- 5 61 49 4-01-00 Vert CR L/240 L/999(-0.00) 4- 5 Max Horiz = 0 / +24 at Joint 1 Horz LL 0.75in ( 0.00) @Jt 1 Member Forces Summary Horz CR 1.25in ( 0.00) @Jt 1 ..Mem... Ten comp .CSI. Loads Summary TC 1- 2 7 46 0.04 Vert CR and Horz CR are the vertical and 2- 3 4 3 0.16 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 3-OH 0 0 0.00 live load occurring at [2-11-12] using a 1.00 Full and 0.00 Reduced load plus the creep component of deflection BC 1- 4 4 3 0.07 factor. due to dead load, computed as Defl LL + 4- 5 4 3 0.07 Report for loading combinations and additional details. (Kcr - 1) x Defl_DL in accordance with See Loadcase Re p ANSI/TPI 1. 5-OH 0 0 0.00 Dead Loads may be slope adjusted: d: > 12.0/12 Web 2- 4 129 37 0.01 3- 5 213 66 0.03 Bracing Data Summary Notes ------------Bracing Data ------------ Valley Truss application only Chords; continuous except where shown Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Web Bracing -- None Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Plate offsets(X, Y): A "pm" next to the plate size indicates that the plate has been user (None unless indicated below) modified; see Plate Offsets for any special positioning requirements. Jnt2(-01-11,00-05), Jnt3(-00-03,-01-03), Less than 0.25/12 pitch requires adequate drainage to prevent ponding. Jnt4(01-07,00-01), Jnt5(-00-03,01-03) _ No.69577 - • Q STATE OF jP4OR10P.•' G=� coA # 000ss��NAL 3/9/2021 NOTICE A copy of this design shell be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1. 2.1 Notes" page for additional Information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 e plates are 20 gauge, unless the specked plate size is followed by a'-18" which indicates an 18 gauge plate, or •S# 18'. which indicates a high tension 18 gauge plate. - CSHelp@strongtie.com tngurwg: [uiyrsnc;i'_es 00676 - Lobo - Paleo Pine Circle City: 1 Truss: WE Customer: Lu Dial SID: 0000940936 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 2-7-0 2-7-0 2-7-0 I 5-2-0 1 2 3 5/12 -5/12 _ 3x4= ,-� 3x41z- 3x4-- 0 2x3u 2-7-0 2-7-0 r 2-7-0 I 5-2-0 1 4 3 J J 5-2-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 ps£ Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 1.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L = 63.7 ft B =' 54.0 ft 200 lb BC Accessible Ceiling: No Total 31.0 P1t 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 1.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20`,f Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 Reactions not shown: down < 400 and up < 150 TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 ---- Reaction Summary (plf) ----- Vert LL L/360 L/999(-0.00) 4- 3 Webs 2x4 SP (ALSC6-2013) #2 Jnt-Jnt React -Up- --Width- Vert DL L/120 L/999(-0.00) 4- 3 1- 3 62 50 5-02-00 Vert CR L/240 L/999(-0.00) 4- 3 Member Forces Summary Max Horiz -23 / +23 at Joint 1 Horz LL 0.75in ( 0.00) @Jt 1 ..Mem... Ten Comp .CSI. Horz CR 1-25in ( 0.00) @Jt 1 TC 1- 2 93 30 0.07 Loads Summary 2- 3 79 26 0.07 Vert CR and Horz CR are the vertical and BC 1- 4 14 5 0.03 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 3- 4 14 5 0.06 live load occurring at [2-07-00) using a 1.00 Full and 0.00 Reduced load plus the creep component of deflection Web 2- 4 214 62 0.03 factor. due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with See Loadcase Report for loading combinations and additional details. ANSI/TPI 1. Dead Loads may be slope adjusted: > 12.0/12 Bracing Data Summary Notes ------------Bracing Data ------------ Valley Truss application only Chords; continuous except where shown Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Web Bracing -- None Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Plate offsets (x, Y): (None unless indicated below) �� .. ' ��GENgF' .•�.� � - No.69577 - N~ Q STATE OF !(7 /ice �CRION •' G� �� O��NAL �SSE�.��• COA #30003 / l l l l l l t 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General - 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector P r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified. plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - CsHelp@stxongtie.com engucwg: zulvrJ.U; _es 00676 - Lobo - Paleo Pine Circle Qty. 1 Truss: V3A Customer: Lu Dial SID: 0000940937 TID: 122969 Date: 03 / 08 / 21 Truss Mir. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.25 1.60 N/A Total 31.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 44 197 0.36 2-0H 0 3 0.00 BC 1- 3 62 47 0.39 3- 4 62 47 0.18 4-OH 0 0 0.00 Web 2- 4 397 119 0.12 4-6-8 4-6-8 1 2 5112 2x3[i 3x4 l o 2x311 4-6-8 4-6-8 1 3 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No 4 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims- L - 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 1.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 4 61 48 4-06-08 Max Horiz -51 / +107 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [4-06-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Valley Truss application only Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. \\Itllllll///// ocENSF _Z7 No.69577 0 • STATE OF C(/` coA#3000SS/ONAI- 0 \\\ 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 1- 3 Vert DL L/120 L/999(-0.00) 1- 3 Vert CR L/240 L/999(-0.01) 1- 3 Horz LL 0.75in ( 0.01) @Jt 1 Horz CR 1.25in ( 0.01) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X,1): (None unless indicated below) NOTICE A copy of this design shell be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by ® Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates • Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector r Heipdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - . CSHelp@strongtie.com 00676 - Lobo - Paleo Pine Circle City: 1 Truss: WA Customer: Lu Dial SID: 0000940938 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead our Factors TC 20.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.25 1.60 N/A Total 31.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20`f Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 16 78 0.04 2-OH 0 3 0.00 BC 1- 3 21 15 0.03 3-OH 0 0 0.00 Web 2- 3 161 46 0.03 2-6-8 2-6-8 1 5/12 2x3ii 3x4o 0 2x3ii 2-6-8 2-6-8 1 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) - N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No 3 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 1.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS CSC End Zone: 5-04-13 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 3 61 48 2-06-08 Max Horiz = 0 / +39 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [2-06-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Valley Truss application only Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. ��/.•.•' �tGENSF' ..�.� No. 69577 ��_ QSTATE OF COA # 0003ONAL ,� �` \ 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based.on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or •S# 18 which indicates a high tension 18 gauge plate. -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999( 0.00) 1- 3 Vert DL L/120 L/999( 0.00) 1- 3 Vert CR L/240 L/999( 0.00) 1- 3 Horz LL 0.75in ( 0.00) @it 1 Horz CR 1.25in ( 0.00) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Component Solutions • Truss Studio V 2020.1.2.1 Helpdesk: 1-866-252-8606 t1 f v CSHelp@strongtie.com 00676 - Lobo - Paleo Pine Circle Qty: 1 Truss: V5A Customer. Lu Dial SID: 0000940939 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.25 1.60 N/A Total 31.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 54 239 0.61 2-OH 0 3 0.00 BC 1- 3 88 66 0.56 3- 4 88 66 0.14 4- 5 88 66 0.03 5-OH 0 0 0.00 Web 2- 5 458 118 0.18 5-9-8 5-9-8 5/12 2x4 rn 3x4 N 2x4 5-9-8 5-9-8 1 3 4 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L - 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 £t Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC - 1.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 5 61 48 5-09-08 Max Horiz -72 / +146 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at 15-09-08) using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Valley Truss application only Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. .�` M. M BQ _EN--* . , .. QT _ No.69577 Q� , STATE O�FF �SS/ONAL �\G �\ COA#30003 //111111W 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 1- 3 Vert DL L/120 L/999(-0.00) 1- 3 Vert CR L/240 L/999(-0.00) 1- 3 Horz LL 0.75in ( 0.01) @Jt 1 Horz CR 1.25in ( 0.01) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------- Chords; continuous except where shown Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt2(0,00-10), Jnt5(0,-00-09) NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates M.P • Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector n r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a'-18" which indicates an 18 gauge plate, or'S# 18", which indicates a high tension 18 gauge plate. - o CSHelp@strongti.e. cam EngDrwg: 2019r3RGT_PS 100676 - Lobo - Paleo Pine Circle City: 1 Truss: V6A Customer: Lu Dial SID: 0000940940 TID: 122969 Date: 03 108 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.25 1.60 N/A Total 31.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x9 SP (ALSC6-2013) #2 Webs 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 36 163 0.25 2-OH 0 3 0.00 BC 1- 3 47 35 0.22 3- 4 47 35 0.11 4-OH 0 0 0.00 Web 2- 4 336 97 0.09 3-9-8 3-9-8 1 2 5/12 2x3 ii Ln 3 x 4 2x3ii 3-9-8 3-9-8 1 3 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No 4 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 1.0 End Vertical Exposed: L = Yes R - Yes Wind Uplift Reporting: ASCE7 MWFRS CSC End Zone: 5-04-13 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 4 61 48 3-09-08 Max Horiz = -39 / +83 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at (3-09-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Valley Truss application only Plates designed for Cq at. 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. \`Illllfll///// M:.BOQ' No. 69577 X Q STATE OF �(/ T <ORI&.•' COA#30003�11/111Ill\\\\ 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 1- 3 Vert DL L/12d L/999(-0.00) 1- 3 Vert CR L/240 L/999(-0.00) 1- 3 Horz LL 0.75in ( 0.01) @Jt 1 Horz CR 1.25in ( 0.01) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, l): (None unless indicated below) NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of theinformation set forth by the Building Designer. A seal on this drawing indicates ® Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a %18° which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. n t - a CSHelp@strongtie. com EngOrwg: 2019r3RGT_PS 1-00676 - Lobo - Paleo Pine Circle Oty: 46 Truss: J17 Customer: Lu Dial SID: 0000940941 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Wedge 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 35 0 0.34 1- 2 65 208 1.00 BC 1- 3 0 0 0.83 4-1 Z ,1-4-Q 7-0-0 F� 7-0-0 5/12 7-0-0 7-0-0 1 3 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L - 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R - Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 1 04-00 392 179 08-00 00-10 SPF 425 3 7-00-00 120 3 01-08 00-02 SPF 565 2 7-00-00 170 161 01-08 00-03 SPF 565 Max Horiz = 0 / +208 at Joint 1 Loads Summary This truss,has been designed for the effects of an unbalanced top chord live load occurring at [7-00-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. •.M:.B.pT'%. No. 69577 r Q •• STATE OF 4t, T S/ONAL E�.��• COA#30003 I1II1111 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.08) 1- 3 Vert DL L/120 L/706(-0.11) 1- 3 Vert CR L/240 L/420(-0.19) 1- 3 Horz LL 0.75in ( 0.10) @Jt 1 Horz CR 1.25in ( 0.13) @Jt 1 Ohng CR 2L/240 2L/999( 0.02) 1- 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, l): (None unless indicated below) Jntl(06-01,01-12) NOTICEA copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General -- --- --. Notes' page for additional Information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a'-18" which indicates an 18 gauge plate, or'S# 18", which indicates a high tension 18 gauge plate. CSHelp@strongtie. com Engnrwg: 2019rJRGT-PS 100676 - Lobo - Paleo Pine Circle Qty: 2 Truss: J17A Customer: Lu Dial SID: 0000940942 TID: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1-4-0 6-4-0 S-0 6-4-0 -0- 1 2 3 -5/12 3x42x3ii - 5/12 . N r••I I � N r••I � 1 ' 1ID 3x4= ,'4 4-1 ^' 1 2x3 ll2x4 6-4-0 8-0 6-4-0 7-0-0 1 4 5 J J 7-0-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(P£min_): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = No Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/779(-0-10) 1- 4 Webs 2x4 SP (ALSC6-2013) #2 1 03-14 391 192 08-00 00-10 SPF 425 Vert DL L/120 L/652(-0.12) 1- 4 5 7-00-00 229 183 01-08 00-04 SPF 565 Vert CR L/240 L/355(-0.23) 1- 4 Member Forces Summary 3 7-00-00 71 0 01-08 00-01 SPF 565 Harz LL 0.75in ( 0.13) @Jt 3 ...Mem... Ten Comp .CSI. Max Horiz = 0 / +176 at Joint 1 Harz CR 1.25in ( 0.17) @Jt 3 TC OH- 1 35 0 0.34 Ohng CR 2L/240 2L/999( 0.02) 1- 1 1- 2 60 165 0.08 Loads Summary 27 2- 3 1 27 0. Vert CR and Harz CR are the vertical and BC 1- 9 0 0 0.7575 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 4- 5 0 0 0.59 live load occurring at [6-04-00] using a 1.00 Full and 0.00 Reduced load plus the creep component of deflection Web 2- 4 628 173 0.11 factor. due to dead load, computed as Defl LL + 3- 5 0 0 0.00 See Loadcase Report for loading combinations and additional details. (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Dead Loads may be slope adjusted: > 12.0/12 Bracing Data Summary Notes ------------Bracing Data ------------ Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Chords; continuous except where shown Plates located at TC pitch breaks meet the prescriptive minimum size Web Bracing -- None requirement to transfer unblocked diaphragm. loads across those joints. Plate offsets (X, l): (None unless indicated below) Jnt4(0,-00-12) No.69577 _ Q • STATE OF • �(/` FCORIOP.•' N NAL,"���• 003S1/ COA#3 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates 0k Truss studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the 'Important Information $ General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. n - CSHelp@strongtie. cam EngDrwg: 2019r3RGT_Eng b0676 - Lobo - Paleo Pine Circle Qty: 1 Truss: J17B Customer: Lu Dial SID: 0000940943 TID: 122969 Date: 03 / 08 / 21- Truss Mfr. Contact: Rick Mills Page: 1 of 1 J1-4-OJ 4-6-8 2-5-8 I Fes` 4-6-8 7-0-0 1 2 3 5/12 3x6 N M 3x4= N ' 4-1 rn N I N 2x3 a 2x3 4-6-8 2-5-8 4-6-8 7-0-0 1 4 5 J F 7-0-0 J Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg'Dims: L = 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 1b TC Safe Load: No Repetitive Member Increase: Yes Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R - Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OR Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Sumnary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) f2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.01) 1- 4 Webs 2x4 SP (ALSC6-2013) S2 1 03-14 388 200 08-00 00-10 SPF 425 Vert DL L/120 L/999(-0.01) 1- 4 5 6-10-08 186 90 01-08 00-04 SPF 565 Vert CR L/240 L/999(-0.02) 1- 4 Member Forces Summary 3 7-00-00 71 60 01-08 00-01 SPF 565 Horz LL 0.75in ( 0.00) @Jt 3 ...Mem... Ten Comp .CSI. Max Horiz = 0 / +148 at Joint 1 Horz CR 1.25in ( 0.01) @Jt 3 TC OH- 1 35 0 0.34 Ohng CR 2L/240 2L/999( 0.02) 1- 1 1- 2 380 293 0.43 Loads Summary 2- 3 0 0 0.24 Vert CR and Horz CR are the vertical and BC 1- 4 227 480 0.14 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 4- 5 224 482 0.13 live load occurring at (5-09-04] using a 1.00 Full and 0.00 Reduced load plus the creep component of deflection 5-OH . 0 0 0.00 factor. due to dead load, computed as Defl LL + Web 2- 4 144 0 0.03 See Loadcase Report for loading combinations and additional details. ANSI/TPI)1x Defl_DL in accordance with 2- 5 596 278 0.10 Dead Loads may be slope adjusted: > 12.0/12 Bracing Data Summary Notes ------------Bracing Data ------------ Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Chords, continuous except where shown Plates located at TC pitch breaks meet the prescriptive minimum size Web Bracing -- None requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. Plate offsets (X,Y)' (None unless indicated below) Jnt2(0,-00-02) ` No.69577 - �Q STATE OF .FCORW'.•' \ ``�` COA #30003'y/ONA� ,; 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc In accordance with ESR-2762. All connector r Helpdesk: 1-866-252-8606 rt r plates are 20 gauge, unless the specked plate size is followed by "-18' which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - CSHelp@strongtie. com Engorwg: LU1ViJRGT-P5 1-00676 - Lobo - Paleo Pine Circle Qty: 5 Truss: J13 Customer: Lu Dial SID: 0000940944 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies. 1 ,Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 35 0 0.50 1- 2 29 110 0.26 BC 1- 3 0 0 0.09 1-4-0 3-0-0 3-0-0 1 5/12 3x4= 4-1 ^ I I � z I N 3-0-0 3-0-0 1 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(P£min): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L - 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 251 134 08-00 00-06 SPF 425 3 3-00-00 44 0 03-00 00-01 SPF 565 2 3-00-00 57 60 03-00 00-01 SPF 565 Max Horiz - 0 / +107 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [3-00-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. oCENSF' _ No.69577 _ Q STATE OF /ONAL COA #30003 // I I I I 1 1 I, 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 1- 3 Vert DL L/120 L/999(-0.00) 1- 3 Vert CR L/240 L/999(-0.00) 1- 3 Horz LL 0.75in ( 0.00) @Jt 1 Horz CR 1.25in ( 0.00) @it 1 Ohng CR 2L/240 2L/977( 0.03) 1- 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by ® Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates • Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional Information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. h - CSHelp@strongtie.com EngUtWy: zu19r]AGT Ps D0676 - Lobo - Paleo Pine Circle Qty: 1 Truss: J25A Customer: Lu Dial SID: 0000940945 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 49 203 0.75 BC 1- 3 0 0 0.51 4-11-11 4-11-11 5/12 Ln I 4-1 3x4= N 4-11-11 4-11-11 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L - 63.7 ft B = 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 212 76 08-00 00-05 SPF 425 3 4-11-11 87 0 01-08 00-02 SPF 565 2 4-11-11 127 124 01-08 00-02 SPF 565 Max Horiz - -2 / +120 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [4-11-11] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. \\�ttllliil//�/ .�. B�OT''�, No. 69577 Q STATE OF 'ice jPZORIO. /''�SS/ONAL COA #30003 / /1 1 'I 1 1 I 1\ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building. Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information & General Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.02) 1- 3 Vert DL L/120 L/999(-0.03) 1- 3 Vert CR L/240 L/999(-0.05) 1- 3 Horz LL 0.75in ( 0.03) @Jt 1 Horz CR 1.25in ( 0.04) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Component Solutions ®Truss Studio V -2020.1.2.1 Helpdesk: 1-866-252-8606 H r o CSHelp@strongti.e.com c„yuc wy: cui�c�n — b0676 - Lobo - Paleo Pine Circle Qty: 9 Truss: J25 Customer: Lu Dial SID: 0000940946 TID: 122969 Date: 03 108121 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 35 0 0.41 1- 2 45 175 0.63 BC 1- 3 0 0 0.31 1-4-0 4-11-11 4-11-11 1 i 5/12 � I Ln I 4-1 3x4= II � N I N 4-11-11 4-11-11 1 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1-0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 316 153 08-00 00-08 SPF 425 3 4-11-11 84 , 0 01-08 00-02 SPF 565 2 4-11-11 118 117 01-08 00-02 SPF 565 Max Horiz = 0 / +157 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [4-11-11] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. ``��►IIIIIfff�/ ENgF' y� i No. 69577 STATE OF � � • ' F�OR14P.•'•G��� COAL! 0003IIONAL0\\\�\\ 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the "Important Information & General Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a --18" which indicates an 18 gauge plate, or "Sad 18', which indicates a high tension 18 gauge plate. -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes geflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.02) 1- 3 Vert DL L/120 L/999(-0.02) 1- 3 Vert CR L/240 L/999(-0.05) 1- 3 Horz LL 0.75in ( 0.02) @Jt 1 Horz CR 1.25in ( 0.02) @Jt 1 Ohng CR 2L/240 2L/999( 0.03) 1- 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Component Solutions ®Truss Studio V 2020.1.2.1 Helpdesk: 1-866-252-8606 n � CSHelp@strongtie.com cny urwy: cwr�r�n — b0676 - Lobo - Paleo Pine Circle Qty: 1 Truss: J23A Customer: Lu Dial SID: 0000940947 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 ps£ Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC 1- 2 38 134 0.32 BC 1- 3 0 0 0.19 2-11-11 2-11-11 1 2 5/12 Ln 4-1 101 3x4= 2-11-11 2-11-11 1 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No 3 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B = 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 133 46 08-00 00-03 SPF 425 3 2-11-11 49 0 01-08 00-01 SPF 565 2 2-11-11 72 71 01-08 00-01 SPF 565 Max Horiz = -1 / +69 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at (2-11-11) using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads maybe slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. No. 69577 Q� • STATE OF ((/� COA 00003 1ONAL 0� 3/9/2021 -------Additional Design Checks------ 10 ps£ Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 1- 3 Vert DL L/120 L/999(-0.00) 1- 3 Vert CR L/240 L/999(-0.01) 1- 3 Horz LL 0.75in ( 0.01) @it 1 Horz CR 1.25in ( 0.01) @Jt 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, l): (None unless indicated below) NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. Seethe cover page and the 'Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector t! ` r Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or •S# 18•, which indicates a high tension 18 gauge plate. - CSHelp@strongtia.com —g—g: zul yns r_es r � 60676 - Lobo - Paleo Pine Circle Qty: 9 Truss: J23 Customer: Lu Dial SID: 0000940948 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OR Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mom... Ten Comp .CSI. TC OH- 1 35 0 0.50 1- 2 29 109 0.25 BC 1- 3 0 0 0.09 1-4-0 41, 2-11-11 2-11-11 1 2 5/12 Ln 4-1 3x-4 u, I � � I N 2-11-11 2-11-11 1 -----------Snow Load Specs-------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L - 63.7 ft B - 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summary(Lbs) ---------------- Jot --X-Loc- React -Up- --Width- -Regd -Mat PSI 1 03-14 250 133 08-00 00-06 SPF 425 3 2-11-11 43 0 01-08 00-01 SPF 565 2 2-11-11 56 59 01-08 00-01 SPF 565 Max Horiz = 0 / +107 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at (2-11-111 using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. ��/.• ��GENSF' •.yam; No. 69577 _ OSTATE OF i� FCORX0 •'•G=� coA #30003N16NAL 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a'-18" which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. -------Additional Design Checks------ 10 ps£ Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 1- 3 Vert DL L/120 L/999(-0.00) 1- 3 Vert CR L/240 L/999(-0.00) 1- 3 Horz LL 0.75in ( 0.00) @Jt 1 Horz CR 1.25in ( 0.00) @it 1 Ohng CR 2L/240 2L/975( 0.03) 1- 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Component Solutions • Truss Studio V 2020.1.2.1 h Helpdesk: 1-866-252-8606 -o CSHelp@strongtie.com 00676 - Lobo - Paleo Pine Circle Qty: 14 Truss: J21 Customer: Lu Dial SID: 0000940949 TID: 122969 Date: 03 / 08 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 Code/Design: FBC-2020/TPI-2014 PSF Live Dead Dur Factors TC 20.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.25 1.60 N/A Total 40.0 Plt 1.25 1.60 N/A Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf Material Summary TC 2x4 SP (ALSC6-2013) #2 BC 2x4 SP (ALSC6-2013) #2 Member Forces Summary ..Mem... Ten Comp .CSI. TC OH- 1 35 0 0.55 1- 2 351 76 0.18 BC 1- 3 0 0 0.14 1-4-0 11-11 11 1 1 2 5/12 4-1 3x4= 8-15 I I'L 1 -----------Snow Load Specs---------- ASCE7-16 Ground Snow(Pg) = N/A Risk Cat: II Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low -Slope Minimums(Pfmin): No Unbalanced Snow Loads: No Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 170 mph Risk Cat: II Exposure Cat: C Bldg Dims: L = 63.7 ft B = 54.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 5.0 BC = 5.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 5-04-13 Reaction Summary --------------Reaction Summrary(Lbs)---------------- Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI 1 02-12 238 191 05-08 00-06 SPF 453 3 11-11 41 41 01-08 00-01 SPF 565 2 11-11 53 33 01-08 00-01 SPF 565 Max Horiz = 0 / +56 at Joint 2 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [11-11) using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Dead Loads may be slope adjusted: > 12.0/12 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. \�,t►IIIII///�/ ��. ocENSF . y� No. 69577 e. Q STATE OF �� � FZORtOP.• ��� COA #30003// i 3/9/2021 -------Additional Design Checks------ 10 psf Non -Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: No 300 lb TC Maintenance Load: No 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999( 0.00) 1- 3 Vert DL L/120 L/999( 0.00) 1- 3 Vert CR L/240 L/999( 0.00) 1- 3 Horz LL 0.75in ( 0.00) @it 1 Horz CR 1.25in ( 0.00) @Jt 1 Ohng CR 2L/240 2L/885( 0.04) 1- 1 Vert CR and Horz CR are the vertical and horizontal deflections due to live load plus the creep component of deflection due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. Bracing Data Summary ------------Bracing Data ------------ Chords; continuous except where shown Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Aseal on this drawing indicates ® Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General - 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector - Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specified plate size is followed by a "-18" which indicates an 18 gauge plate, or •S# 18°, which indicates a high tension 18 gauge plate. = CSHelp@strongtia.com 00676 - Lobo - Paleo Pine Circle Qty: 4 Truss: J3 Customer: Lu Dial SID: 0000940950 TID: 122969 Date: 03 / 09 / 21 Truss Mir.. Contact: Rick Mills Page: 1 of 1 J1-10-1OJ 5-4-4 4-5-12 [ ■ r� 5-4-4 9-10-0 1 -57# 2 3 53# -57# 119# 5 33# 11�9# - 3.5355/12 3x4- n, I ' N � Ol 3x4= rn 4-1 ' n1 X G IN 2x3ii 2x3-- -42# -42# 21# 48# 21# 48# 5-4-4 4-5-12 I 5-4-4 9-10-0 1 4 5 J J F 9-10-0 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Our Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 Lum 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.02) 4- 5 Webs 2x4 SP (ALSC6-2013) #2 1 05-04 248 175 10-09 00-06 SPF 425 Vert DL L/120 L/999(-0.04) 4- 5 5 9-08-08 216 123 01-08 00-04 SPF 565 Vert CR L/240 L/999(-0.06) 4- 5 Member Forces Summary 3 9-10-00 80 75 01-08 00-02 SPF 565 Horz LL 0.75in ( 0.01) @Jt 1 ..Mem... Ten Comp .CSI. Max Horiz 0 / +0 at Joint 1 Horz CR 1.25in ( 0.01) @Jt 1 TC OR- 1 22 20 0.14 Ohng CR 2L/240 2L/999(-0.02) 1- 1 1- 2 390. Loads Summary 50 49 55 2- 3 50 99 0.55 Vert CR and Horz CR are the vertical and BC 1- 4 467 320 0.43 Corner Girder designed to carry: horizontal deflections due to live load 4- 5 467 320 0.40 CornerJacks Side SB End SB Cant(S) Cant(E) plus the creep component of deflection 5-OH 0 0 0.00 Open Auto Auto 0 0 due to dead load, computed as Defl LL + Web 2- 4 86 0 0.02 (Kcr - 1) x Defl_DL in accordance with 2- 5 341 499 0.16 Loads based on maximum and minimum reactions from tie-in spans ANSI/TPI 1. Domain Max Min Location Dir Description Transfer loads: Bracing Data Summary TC 53 -33 1-05-05 Vert J21 @ 135 Deg ------------Bracing Data ------------ TC 53 -33 1-05-05 Vert J21 @ -135 Deg Chords; continuous except where shown TC 56 -57 4-03-04 Vert J23 @ 135 Deg Web Bracing --None TC 56 -57 4-03-04 Vert J23 @ -135 Deg TC 119 -114 7-01-03 Vert J25 @ 135 Deg Plate offsets (X,1): TC 119 -114 7-01-03 Vert J25 @ -135 Deg` (None unless indicated below) BC 41 -42 1-05-05 Vert J21 @ 135 Deg BC 41 -42 1-05-05 Vert J21 @ -135 Deg BC 21 11 4-03-04 Vert J23 @ 135 Deg BC 21 11 4-03-04 Vert J23 @ -135 Deg BC 48 12 7-01-03 Vert J25 @ 135 Deg BC 48 12 7-01-03 Vert J25 @ -135 Deg Distributed Loads (plf) - Based on Live Load Domain Load Uplift Start Load Uplift End Dir Description TC -0.0 0-1-10-10 .0 0 --05 Vert Standard TC -0.0 0-1-10-10 60.0 -51 -0303-03 Vert Standard \\ `V BOO \�\_`••M ••/��/ TC 4.0 0 -11-05 -0.0 0 0 Vert Standard TC 60.0 -51 -03-03 -0.0 0 1-04-04 Vert Standard T %/ •'' \,\GEMS`( '. y TC 3.8 -3-1-10-10 3.8 -3 9-10-00 Vert Standard �,• '•,� i BC 1.3 0 0 1.3 0 9-10-00 Vert Standard This truss has been designed for the effects of an unbalanced top chord No. 69577 •: live load occurring at [9-10-00) using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. y. _ _ * 7[ •• Dead Loads may be slope adjusted: > 12.0/12 �/� ' Notes O STATE OF ((7 •• R • Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size ,� •, (r�[�t�P•,• N j�S• •......•• \\ requirement to transfer unblocked diaphragm loads across those joints. \\ - "3/0NAI.•�� COA #30003 //// f t l l 1 1 0 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based an design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates EMT V • Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes" page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a "-18" which indicates an 18 gauge plate, or "S# 18', which indicates a high tension 18 gauge plate. r n 4 r - CSHelp@stmongtie.com EngDr g: 2019r3RGT-Eng b0676 - Lobo - Paleo Pine Circle Qty: 1 Truss: J3A Customer: Lu Dial SID: 0000940951 Tb: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 11-10-10� 5-4-4 4-5-12 + I I� 5-4-4 9-10-0 1 2 3 53# -57# 119# 533# 722# 12y8# - 3.5355/12 3x4- M I - fV � Cn 4-1 3x4= rrf ' ^^ X El 2x3it 2x3- f $ $ -42# -42# 32# 58# 21# 48# 5-4-4 I 4-5-12 5-4-4 9-10-0 1 4 5 k 9-10-0 J Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 1. 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B = 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1-0 300 lb TC Maintenance Load: No Spacing: 2-00-00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 lb TC Safe Load: No Repetitive Member Increase: No fLow-Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC = 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x4 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999(-0.04) 4- 5 Webs 2x4 SP (ALSC6-2013) #2 1 05-04 616 342 10-09 00-15 SPF 425 Vert DL L/120 L/999(-0.06) 4- 5 5 9-08-08 485 244 01-08 00-09 SPF 565 Vert CR L/240 L/999(-0.10) 4- 5 Member Forces Summary 3 9-10-00 183 168 01-08 00-03 SPF 565 Horz LL 0.75in ( 0.01) @Jt 3 ..Mem... Ten Comp .CSI. Max Horiz = 0 / +208 at Joint 1 Horz CR 1.25in ( 0.02) @Jt 3 TC OH- 1 36 0 0.71 Ohng CR 2L/240 2L/611( 0.07) 1- 1 1- 2 570 1156 0.68 Loads Summary 2- 3 52 93 0.75 Vert CR and Horz CR are the vertical and BC 1- 4 1081 824 0.62 This truss has been designed for the effects of an unbalanced top chord horizontal deflections due to live load 4- 5 1081 824 0.65 live load occurring at [9-10-00] using a 1.00 Full and 0.00 Reduced load plus the creep component of deflection 5-OH 0 0 0.00 factor. due to dead load, computed as Defl LL + Web 2- 4 289 0 0.06 See Loadcase Report for loading combinations and additional details. (Kcr - 1) x Defl_DL in accordance with ANSI/TPI 1. 2- 5 879 1153 0.38 Dead Loads may be slope adjusted: > 12.0/12 Loads based on maximum and minimum reactions from tie-in spans Bracing Data Summary Domain Max Min Location Dir Description Transfer loads: ------------Bracing Data ------------ TC 53 -33 1-05-04 Vert J21 @ 135 Deg Chords, continuous except where shown TC 53 -33 1-05-04 Vert J21 @ -135 Deg Web Bracing -- None TC 72 -69 4-03-03 Vert J23A @ -135 Deg TC 56 -57 4-03-03 Vert J23 @ 135 Deg Plate offsets(X, Y): TC 128 =120 7-01-02 Vert J25A @ -135 Deg (None unless indicated below) TC 119 -114 7-01-02 Vert J25 @ 135 Deg BC 41 -42 1-05-04 Vert J21 @ 135 Deg BC 41 -42 1-05-04 Vert J21 @ -135 Deg BC 32 . 2 4-03-03 Vert J23A @ -135 Deg BC 21 11 4-03-03 Vert J23 @ 135 Deg BC 58 6 7-01-02 Vert J25A @ -135 Deg BC 48 12 7-01-02 Vert J25 @ 135 Deg Notes M Plates designed for Cq 0.80 Rotational Tolerance of 10.0 degrees ��\��\ . • "BO�Tl��i at and Plates located at TC pitch breaks meet the prescriptive minimum size •• \.1C'ENS( •••• y requirement to transfer unblocked diaphragm loads across those joints. �',•••• ••,+� i No.69577 _ Q� , STATE OF C(/` 'i F40RION G\=� coon 0003 3/9/2021 NOTICE A copy of this design shall be fumished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates _�Qk Truss Studio V acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the "Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 R 4 plates are 20 gauge, unless the specified plate size is followed by a •48° which indicates an 18 gauge plate, or °S# 18", which indicates a high tension 18 gauge plate. - CSHelp@strongtie. c:= EngOrwg: 1U19rJRGT_Eng 60676 - Lobo - Paleo Pine Circle Qty: 2 Truss:.13D Customer: Lu Dial SID: 0000940952 TID: 122969 Date: 03 / 09 / 21 Truss Mfr. Contact: Rick Mills Page: 1 of 1 1-10-10 4-2-2 4-2-2 1 2 53# 53# 3.5355/12 rn ri - 3x4= r-I 4-1 I I � N I -42# -42# 4-2-2 4-2-2 1 3 Code/Design: FBC-2020/TPI-2014 -----------Snow Load Specs ---------- ----------Wind Load Specs ---------- -------Additional Design Checks------ PSF Live Dead Dur Factors ASCE7-16 Ground Snow(Pg) = N/A ASCE7-16 Wind Speed(V) = 170 mph 10 psf Non -Concurrent BCLL: Yes TC 20.0 10.0 Live Wind Snow Risk Cat: II Terrain Cat: C Risk Cat: II Exposure Cat: C 20 psf BC Limited Storage: Yes BC 0.0 10.0 1. 1.25 1.60 N/A Roof Exposure: Sheltered Bldg Dims: L - 63.7 ft B - 54.0 ft 200 lb BC Accessible Ceiling: No Total 40.0 Plt 1.25 1.60 N/A Thermal Condition: All Others(1.0) M.R.H(h) = 15.0 ft Kzt = 1.0 300 lb TC Maintenance Load: No Spacing: 2-00. 00 o.c. Plies: 1 Unobstructed Slippery Roof: No Bldg Enclosure: Enclosed 2000 1b TC Safe Load: No Repetitive Member Increase: No Low -Slope Minimums(Pfmin): No Wind DL(psf): TC = 5.0 BC - 5.0 Unbalanced TCLL: Yes Green Lumber: No Wet Service: No Unbalanced Snow Loads: No End Vertical Exposed: L = Yes R = Yes Fab Tolerance: 20% Creep (Kcr) = 2.0 Rain Surcharge: No Ice Dam Chk: No Wind Uplift Reporting: ASCE7 MWFRS OH Soffit Load: 2.0 psf C&C End Zone: 5-04-13 Material Summary Reaction Summary Deflection Summary TC 2x9 SP (ALSC6-2013) #2 --------------Reaction Summary(Lbs)---------------- TrussSpan Limit Actual(in) Location BC 2x4 SP (ALSC6-2013) #2 Jnt--X-Loc- React -Up- --Width- -Regd -Mat PSI Vert LL L/360 L/999( 0.02) 1- 3 1 05-04 143 70 10-09 00-04 SPF 425 Vert DL L/120 L/999( 0.01) 1- 3 Member Forces Summary 3 4-02-02 , 34 29 01-08 00-01 SPF 565 Vert CR L/240 L/999( 0.02) 1- 3 ...Mem... Ten Comp .CSI. 2 4-02-02 30 23 01-08 00-01 SPF 565 Horz LL 0.75in ( 0.01) @Jt 1 TC OH- 1 22 20 0.14 Max Horiz - 0 / +0 at Joint 1 Horz CR 1.25in ( 0.01) @it 1 1- 2 8 23 0.17 Ohng CR 2L/240 2L/999(-0.02) 1- 1 BC 1- 3 0 0 0.19 Loads Summary Vert CR and Horz CR are the vertical and Corner Girder designed to carry: horizontal deflections due to live load CornerJacks Side SB End SB Cant(S) Cant(E) plus the creep component of deflection Open Auto Auto 0 0 due to dead load, computed as Defl LL + (Kcr - 1) x Defl_DL in accordance with Loads based on maximum and minimum reactions from tie-in spans ANSI/TPI 1. Domain Max Min Location Dir Description Transfer loads: Bracing Data Summary TC 53 -33 1-05-05 Vert J21 @ 135 Deg ------------Bracing Data ------------ TC 53 -33 1-05-05 Vert J21 @ -135 Deg Chords; continuous except where shown BC 41 -42 1-05-05 Vert J21 @ 135 Deg Web Bracing -- None BC 41 -42 1-05-05 Vert J21 @ -135 Deg Distributed Loads (plf) - Based on Live Load Plate offsets (X, Y): Domain Load Uplift Start Load Uplift End Dir Description _ (None unless indicated below) TC -0.0 0-1-10-10 4.0 0 -11-05 Vert Standard TC -0.0 0-1-10-10 60.0 -51 -03-03 Vert Standard TC 4.0 0 -11-05 -0.0 0 0 Vert Standard TC 60.0 -51 -03-03 -0.0 0 1-04-04 Vert Standard TC 3.8 -3-1-10-10 3.8 -3 4-02-02 Vert Standard BC 1.3 0 0 1.3 0 4-02-02 Vert Standard This truss has been designed for the effects of an unbalanced top chord live load occurring at [4-02-021 using a 1.00 Full and 0.00 Reduced load \ttllllt�/f \\\ factor. See Loadcase Report for loading combinations and additional details. \\\ a M. BO " '•. �T // Dead Loads may be slope adjusted: > 12.0/12 �\ ��`".•'•• \cENS Notes a Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees No. 69577 •� Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. _ y 1, _ 0 Q STATE OF C(/� /��S' COAa3000s/ �/NAL 0\\\\\ 3/9/2021 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by Component Solutions the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. Asset on this drawing indicates ® Truss Studio v acceptance of professional engineering responsibility solely for the truss component design shown. Sae the cover page and the "Important Information & General 2020.1.2.1 Notes' page for additional information. All connector plates shall be manufactured by Simpson Strong -Tie Company, Inc in accordance with ESR-2762. All connector Helpdesk: 1-866-252-8606 plates are 20 gauge, unless the specked plate size is followed by a'-18' which indicates an 18 gauge plate, or "S# 18", which indicates a high tension 18 gauge plate. - CSHelp@strongtie.com Engmrwg: 2019r3RGT_Eng SIMPSON Strong -Tie • GABLE STUD BRACING DETAIL -140 MPH (NOMINAL), I TD-GBL-0007B 170 MPH (ULTIMATE) 1. This detail provides bracing/reinforcement options for the gable studs to resist the out -of -plane wind loading. Refer to the individual truss design drawing for bracing/reinforcement requirements for resisting the vertical (in -plane) loads assumed in the design of the gable end frame. Additional bracing/reinforcement at the end of the buildingand/or at the gable end wall may be required. Refer to the Building Designer/Construction Documents for all gable end frame and roof system bracing requirements. For additional information, see BCSI-B3. 2. This detail does not apply to structural gables. 3. Connection requirements between the gable end frame and the wall to be specified by the Building Designer. 4. The gable end frame must match the profile of the adjacent trusses. Do not use a gable end frame with a flat bottom chord next to trusses with sloped bottom chords, such as scissor or vaulted trusses. Date: 06/11/2014 1 Rev:B I Pg. 1 of 1 Diagonal Bracing @ 4'-0" O.C. Max. Gable Stud Bracing (24" O.C. Max) 'Diagonal braces not shown for clarity. See Section A -A. GABLE END WITH STUD BRACING/REINFORCEMENT MINIMUM GABLE MAX. WITHOUT L- SCAB DIAGONAL BRACING DIAGONAL BRACING STUD SIZE, GABLE BRACE REINFORCEMENT' REINFORCEMENT' @ MID -SPAN @ 1/3 POINTS SPECIES & GRADE STUD SPACING 3 MAXIMUM STUD LENGTH 12" O.C. 3-10-0 1 6-4-8 1 7-8-4 1 7-8-4 11-6-4 2X4 SPF STUD 16" O.C. 1 3-3-12 1 5-6-4 6-7-12 1 6-7-12 9-11-12 or STANDARD 24" O.C. 1 2-8-8 1 4-6-0 5-5-4 1 5-5-4 8-1-12 1. L- and Scab Reinforcements shall be minimum 2x4 stud grade and must be a minimum of 90% of the gable stud length. Fasten the reinforcement member to the gable stud with 10d nails @ 6" o.c. 2. Attach horizontal reinforcing member at mid -span (or 1/3 points as required) of the longest stud and install diagonal bracing @ 4' o.c. (max) as shown in Section A -A. 3. Tabulated maximum stud lengths are based on components and cladding wind pressures using the wind design parameters listed in the detail limitations. Gable stud deflection criteria is U240. 5-8d nails connecting Min. 2x4 #2 blocking between sheathing to first 2 trusses (min) as shown. Gable Stud blocking (Typ.) Toe -nail blocking to trusses Roof Sheathing with 2-1 Old nails at each end. Fasten diagonal brace to gable stud with 4-16d nails Bracing at 1/3 points as required (See Table) End Wall 2-10d Toe -nails (Typ-) Trusses @ 24" O.C. Max. 2x6 diagonal brace at 48" O.C. (max Attach to gable stud with 4-16d nails and to blocking with 5-10d nails. Horizontal L-reinforcement (located at mid -span or 1/3-points of longest stud as required per table.) SECTION A -A 10d nails GABLE 10d nails X @ 6" o.c. @ 6" o.c. GABLE < STUD L-REINF. STUD SCAB REINF. SECTION 13-13 SECTION C-C 2-10d nails into top reinf. member (Typ. ea stud) 4-10d nails into bottom reinf. member— (Typ. ea stud) 2x6 Diagonal Brace (Approx. 45-degrees to roof diaphragm) y" Fasten L-reinforcement members together with 16d nails @ 6" O.C. Min. 2x6 Min. 2x4 NOTE: Diagonal braces over 6'-3" require a 2x4 T-brace attached to one narrow edge. Diagonal braces over 12'-6" require 2x4s attached on both narrow edges. The braces must cover 90% of the diagonal brace and shall be fastened to the narrow edge with 10d nails at 6" o.c. (min. 3" end distance). When attached on both narrow edges, stagger the nails on each side by 3". DETAIL LIMITATIONS: Wind Speed Equivalent Nail Dimension Max. Mean Roof Height: 30' Nominal Ultimate 16d = 3.5" x 0.162" Category: II 140 mph (170 mph) 10d = 3" x 0.148" Exposure: B or C 8d = 2.5" x 0.131" Load Duration Factor: 1.6 Wind Speed: 140 mph Nominal \\�iittllrrri/i No.69577 _ '•.cr may- ' �` Q STATE OF coAt ooa� �1NAI . I0 3/9/2021 IThis detail is to be used only for the application and conditions indicated herein, and its suitability for any particular truss/project shall be verified (by others). This detail is not intended to I Simpson Strong -Tie Company I supersede any project -specific details provided in the Construction Documents. Truss configurations shown are for illustration only. Refer to the truss design drawing(s) accompanying this detail for specific truss design information. Simpson Strong -Tie Inc. is not responsible for any deviations from this design. INDIVIDUAL WEB REINFORCEMENT DETAIL NOTES: 1. This detail provides web reinforcement options that may be used as an alternative to continuous lateral restraint (CLR) when installing CLRs in combination with diagonal bracing is not practical or desired. 2. 'Refer to the truss design drawing for web lateral restraint requirements. A EEKI on the truss design drawing indicates that continuous lateral restraint is required at the locations shown (either at the midpoint or 1/3-points of the web Fnember). Refer to the tables below for acceptable web reinforcement options that may be used in place of one or two rows of CLR. 3. This detail may not be used to substitute CLRs for T-, L-, I- or scab reinforcements that are specified on the truss design drawing. 4. T-, L-, I- and scab web reinforcements must be the same or better species and grade of the web member as indicated on the truss design drawing. 5. All reinforcements must extend to within 6" of each end of the web member. 6. This detail does not apply to single -ply webs that exceed 14' in length. 6) & 1 Row of CLR @ 2 Rows of CLRs Web Mid -point @ Web 1/3 points WEB REINFORCEMENT OPTIONS FOR SINGLE -PLY TRUSSES' Specified Acceptable Web Reinforcement Web Member Web Substitutions - Type & Size Reinforcement -to -Web Lateral Member Connection Restraint Size Requirements (CLRs) T- L- Scab I - 2x4 2x4 2x4 2x4 --- 1 R ow @ Mid -point 2x6 2x6 2x6 2x6 2x8 2x8 2x8 2x8 --- 16d gun nails @ 6" on -center 2x4 2-2x4 2 Row @ 1/3-points No substitutions allowed I 2x6 2-2x6 2x8 I 2-2x8 WEB REINFORCEMENT OPTIONS FOR 2-PLY TRUSSES' Specified Acceptable Web Reinforcement Web Member Web Substitutions - Type & Size Reinforcement -to -Web Lateral Member Connection Restraint Size Requirements (CLRs) T- L- Scab I- 2x4 2x4 2x4 --- --- 1 Row @ 2x6 2x6 2x6 --- --- Mid-point 2x8 2x8 2x8 --- --- 16d gun nails @ 6" on -center 2x4 2-2x4 2 Row @ 1/3-points No substitutions allowed I 2x6 2-2x6 2x8 I 2-2x8 1. The maximum allowable web length for single -ply trusses is 14'. 2. For 2-ply trusses, the reinforcement must be nailed to both plies of the web with the nailing pattern specified in the table. 3. For the scab reinforcement, 2 rows of 10d gun nails @ 6" o.c may be used in place of 16d gun nails for attaching the reinforcement to the web. 4. For I -reinforcement, attach each 2x_member to opposite edges of the web using the nailing pattern specified in the table. Nail Dimension 16d=3.5"x0.131" 10d = 3" x 0.120" D-WEBREINFORCE Date: 06111/2014 1 Rev:A I Pg.1 of 1 Web tuber ryp•) II I , I >< 1 Add member to both edges for—_7 I -Reinforcement T- Reinforcement (I -Reinforcement similar) L- Reinforcement Scab Reinforcement M. 130 No. 69577 Q STATE OF . , O OR1D COA #30003 / / I / ' 1 ~U1111 3/9/2021 This detail is to be used only for the applicafion and conditions indicated herein, and its suitability for any particular truss/project shall be verified (by others). This detail is not intended to Simpson Strong Tic Company supersede any project -specific details provided in the Construction Documents. Truss configurations shown are for illustration only. Refer to the truss design drawings) accompanying this detail for specific truss design information. Simpson Strong -Tie Inc. is not responsible for any deviations from this design. EStronSg-Tie N LATERAL RESTRAINT & DIAGONAL BRACING DETAILS FOR I D-WEBCLRBRACE WEB MEMBERS This detail provides information for laterally restraining and bracing web members to prevent lateral buckling using continuous lateral ,restraints (CLRs) in combination with diagonal bracing. In addition to the CLRs indicated on the truss design drawing, diagonal bracing must be installed as indicated in this detail and BSCI-133. See WEBREINFORCE for web reinforcement options that may be used as an -alternative to this detail when installing CLRs and diagonal bracing is not practical or desired. Properly attached full-length sheathing satisfies (may replace) any bracing requirements specified for end vertical webs. Refer to the Construction Documents for additional bracing requirements. Note: Not all truss members shown for clarity. Date: 06/18/2014 1 Rev:A I Pg. 1 of 1 1 row of CLR @ mid -points 2 rows of CLR Co) 1/3-points WEB MEMBERS WITH LATERAL RESTRAINT Install 2x4 diagonal bracing at each end nnA n+ m,nni'J0' along the length of the gonal Bracing Details 2 & 3 Min. 2x4xl2' CLRs'installed on web members where indicated on the truss design drawing. Attach CLRs to each web with min. 2-10d nails uvenap enas oT ULRs at least one truss spacing or use splice detail (see Detail 1) For webs with one row of CLRs, diagonal bracing shall be installed using Option 2A or 2B. Attach diagonal braces to each truss with min. 2-10d nails. . 45 Option 2A Option 2B Detail 2 - Diagonal Bracing for 1 Row of CLRs DETAIL LIMITATIONS: 1. Restraint and Bracing Material min. 2x4 stress graded lumber. 2. This detail does not address permanent building stability bracing to resist lateral forces acting on the building. 3. This detail shall not supersede any project -specific truss member permanent bracing design for the roof framing structural system. //%/.%/.%/.% 1�11/11�� �1 Web CLR splice CLR Min. 2'-long 2x_ scab block centered over the CLR splice and web. Attach to CLR with min. 8-10d nails on each side of splice. Detail 1 - CLR Splice For webs with 2 rows of CLRs, diagonal bracing shall be installed using Option 3A or 3B. Attach diagonal braces to each truss with min. 2-10d nails. I%< F s 5° Option 3A Option 3B Detail 3 - Diagonal Bracing for 2 Rows of CLRs Nail Dimensions: 10d=3"x0.128" \\�Iltlllir//�� No. 69577 ��. STATE OF - "40RIDP.•'' �ls S70 00A #30003 TONAL I` \\� 3/9/2021 This detail is to be used only for the application and conditions indicated herein; and its suitability for any particular truss/project shall be verified (by others). This detail is not intended to Simpson Strong -Tie Company supersede any project -specific details provided in the Construction Documents. Truss configurations shown are for illustration only. Refer to the truss design drawing(s) accompanying this detail for specific truss design information. Simpson Strong -Tie Inc. is not responsible for any deviations from this design.