Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR- BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-18 Builder Name: Street: 3613 GROVE CT Permit Office: ST. LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number. Owner. Jurisdiction: Design Location: FL, Fort Pierce County: SL Lucia (Florida Climate Zone 2 ) 1. New construction ore)isting New (From Plans) 10. Wall Type41819.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 1617.10 ft2 b. Frame - Wood, Adjacent R=11.0 202.22 ft2 3. Number of units, If multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 2 d. WA R= ft2 11. Ceiling Types (1832.0 sqf .) Insulation Area 5. Is this a wont case? No a. Under Attic (Vented) R--40.0 1832.00 ft2 6. Conditioned floor area above grade (W) 1832 b. NIA R= ft2 Conditioned floor area below grade (fN) 0 c. N/A R= ft' 7. Windows(279.2 sgft.) Description Area 12. Ducts a. Sup: Attic, Rat Attic, AH: Main R ft2 6 482 a. U-Factor. Dbl, U=0.62 279.17 f ' -SHGC: SHGC=0.26 b. U-Factor. WA ft' 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 38.5 SEER:16.00 c. U-Factor. N/A fN SHGC: Area Weighted Average Overhang Depth: 7.029 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0260 a. Electric Strip Heat 24.8 COP:1.00 8. Skyllghts Area c. U-Factor.(AVG) NIA ftl 15. Hot water systems SHGC(AVG): WA a. Electric Cap: 50 gallons 9. Floor Types (1832.0 sgff.) Insulation Area EF:0.940 a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft2 b. Conservation features b. NIA R= ft= None c. N/A R= ft2 16. Credits Pstat Total Proposed Modified Loads: 52.12 Glass/Floor Area: 0.152 PASS Total Baseline Loads: 57.58 I hereby certify that the plans and specifications covered by Review of the plans and 4-IHE STAT this calculation are in compliance with the Florida Energy specifications covered by this .y��� Code. calculation. indicates compliance the Florida Energy Code. with PREPARED BY: Before constriction is completed Q DATE: 04/16/2021 this building will be inspected for i compliance with Section 553.908 t 1 hereby certify that this building, as d signed, is in compliance Florida Statutes. with the Florida Energy Cod . �D WE'D` OWNER/AGENT: BUILDING OFFICIAL: DATE: .5a l DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/15=14:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 r�nRA eAne anon MIDI IT CI IMMAI?V r..41S[`_KI IAT RFPART I VI\Ir1-- PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-18 User 1 ST. LUCIE COUNTY Detached New (From Plans) Bedrooms: 2 Conditioned Area: 1832 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 3613 GROVE CT County. St. Lucie City, State, Zip: FORT PIERCE. FL, 34951 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1832 17770A SPACES Number Name Area Volume Ifitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1832 17770A Yes 3 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 186.8 It 1832 ft' — 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Flat Olelslate 2048 ft' 0 T Medium N 0.4 N 0.9 No 0 26.57 ArnC V/ # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 150 1832 It' N N CEILING # Ceiling Type Space R Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 1832 ft' 0.1 Wood 4/1V20214:28 PM EnergyGauga4D USA 7.0.00 - FleRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 rnn�� nAAC 02MA INDI IT CI IMMADV 11!1-IP(`_KI ICT PPPART WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Spate RAte'lle Ft In Ft In Area RAW- Erailfinn Absor Graff - _ 1 N Exterior Concrete Block - Ext Insul Main 4.1 58 2 9 4 542.9 ft' 0 0 0.3 0 _ 2 E Exterior Concrete Block- Ext Insul Main 4.1 18 6 9 4 172.7IF 0 0 0.3 0 _ 3 S Exterior Concrete Block - Ext Insul Main 4.1 53 10 9 4. 602.4 W 0 0 0.3 0 _ 4 W Exterior Concrete Block - Ext Insul Main 4.1 37 5 10 8 399.11112 0 0 0.3 0 5 Garage Frame - Wood Main 11 21 8 9 4 202.2 fe 0 0.25 0.3 0 WINDOWS Orientation shown is the entered Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 2 ft 0 In 1 ft 0 In None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft' 2 ft 0 in 1 ft 0 in None None 3 e 2 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft' 8 It 0 In 1 ft 0 in None None 4 e 2 Metal Double (Clear) Yes 0.62 0.26 N 24.0 ft' 10 it 0 In 1 ft 0 in None None 5 s 3 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft? 2 ft 0 in 1 ft 0 In None None 6 s 3 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft' 2 It 0 In 1110 In None None 7 s 3 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft' 2 ft 0 In 1 ft 0 In None None 8 w 4 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft' 2 ft 0 in 1 ft 0 in None None 9 w 4 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft' 10 It 0 in 2 ft 4 in None None 10 W 4 Metal Double (Clear) Yes 0.62 0.26 N 96.0 ft' 10 It 0 in 2 ft 4 in None None GARAGE # FlocrArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 583 ft' 583 ft' 64 ft 9.3 ft 1 INFILTRATION # Scope Method SIA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000431 2073.2 113.74 213.54 .1365 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 24.82 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:16 38.5 kBtu/hr cfm 0.7 1 sys#1 4/15/20214:28 PM EnergyGouge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 rnnRA oAne en#2n 111101IT CI IMMA12V P_41Ff_ICI ICT RFPART HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94- 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model# Area Volume FEF None None fF DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 482 ft° Attic -226 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabl(e hermosta[[t:�Y Ceiling Fans:. lxJ Jan [Xl Feb [( j] LXJ Mar �� 114i jj May May Jr (X� un [) Jul [X� [ I Aug nHVenting Sep W Oct Occt �C Nov Nov H Dec DecVeMfng [[ 11 Jan [[ l] Feb [[�xJJ Mar ll�xll Jun [ 1 Jul [ ]Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coaling (WD) 80 80 78 78 78 78 78 78 78 78 78 76 PM Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) 68 68 68 Be 68 so 68 68 66 66 PM 6688 6688 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 . 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbs/sq.ft. 0 fN Oft 0.3 Main 4/15/20214:28 PM EnergyGaugeS USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD .. ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the EnergyPerformance Index, the more efficient the home. - 3613 GROVE CT, FORT PIERCE, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family 9 y p y Detached a. Concrete Block - Ext Insul, Exterior R=4.1 1617.10 ft' b. Frame - Wood, Adjacent R=11.0 202.22 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area S. Is this a worstcase? No a. Under Attic (Vented) R=40.0 1832.00 ft' 6. Conditioned floor area (ft') 1832 b. N/A R= ft' 7. Windows" Description Area c. N/A 12. Ducts, location & insulation level R= ft z R ft a. U-Factor. Dbl, U=0.62 279.17 ft' a. Sup: Attic, Ret: Attic, AH: Main 6 482 SHGC: SHGC=0.26 b. U-Factor. N/A ft' SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 38.5 SEER:16.00 SHGC: d. U-Factor. N/A ft' 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 24.8 COPA.00 Area Weighted Average Overhang Depth: 7.029 ft. Area Weighted Average SHGC: 0.260 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft' Credits (Performance method) Pstat b. N/A R= ft' c. N/A R= ft' I certify that this home has complied Construction through the above ene in this home before final inspection. based on installed Code compliant f Builder Signature: Address of New Home: 3613 h the Florida Energy Efficiency Code for Building saving features which will be installed (or exceeded) ierwise, a new EPL Display Card will be completed Tres. Date: City/FL Zip: FT Plg _f �i O -Jli� F WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/15/2021 4:28 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: Permit #: Job Information Builder: Community: Lot: NA Address: 3613 GROVE CT City: FORT PIERCE State: FL Zip: 34951 Air Leakage Test Results. Passing results mustmeet either the Performance, Prescriptive, or ER1 Method O PRESCRIPTIVE METHOD -The, building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at.a pressure of 0.2 Inch w.g. (50 Pascals) In Climat6Zones 1 and 2. Q- PERFORMANCE or ERI. METHOD The building or dwelling unit shall be tested and verified as having an -air leakage rate of not exceeding. the selected ACH(50) value, as shown on Form R405-2020 _(Performance) or. R406 2020 (ERI), section labeled as infiltration, sub -section ACH50. ACH(50) specified on Form R405-2020-Energy Calc (Performance) orR406-2020 (ERI): 7.000 x 60 + 17770 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS 0 Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.12 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either Individuals as defined In Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth In Section 489.105(3)(0. (g), or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other Infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, If installed at the time of the test, shall be fully open. Testing Company ' Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 4/15/2021 4:28:59.PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Load Short Date: Apr 14, 2021 Form �°�' -�- wrightsoft Entire House BY Project Information MW-18 3613 GROVE CT, FORT PIERCE, FL 34951 Design • • Htg Clg infiltration Outside db (OF) 41 90 Method Simplified Inside db (*F) 70 72 Construction quality Average Design TD (*F) 29 18 Fireplaces 0 Dailyrange - L Inside humidity No) 30 52 Moisture difference (gdlb) 2 61 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1-041-230A** AHRI ref Coil CBA27UHE-048-230*++TDR AHRI ref 10259425 Efficiency 100 EFF Ef6aency 13.0 EER,16 SEER Heating input 7.3 WV Sensible cooling 26950 Btuh Heating output 24817 Btuh Latentcooling 11550 Btuh Temperature rise 0 OF Total cooling 38500 Btuh Actual airflow 0 cfm Actual airflow 1090 cfm Airflowfactor 0 cf vBtuh Airflowfactor 0.037 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area W) Htg load (Btuh) Clg load (stun) HtyAVF (cfm) CIgAVF 0171) MASTER BATH 210 1782 1081 0 40 BED 2 191 2857 2000 0 74 LAUNDRY/MECH 82 902 1437 0 53 BATH 2. 63 56 .299 0 11 FOYER 91 1003 972 0 36 DINING 126 3505 3417 0 127 IQTCHEN 158 1811 3261 0 121 DEN 183 3901 2806 0 104 GREAT RM 374 3602 8435 0 313 HER W IC 65 1004 542 0 20 MASTER SUITE 242 4904 5122 0 196 ..�..l 1 .10 n n n n rwr-L+n BoldfiaBc values have been mamm8y overridden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. '*' Mightsoft" 2021-Apr-15152220 ''�.. �YR.HIbmMoanluwr-rytrne / Right SJte®Urivorsa1202121AA5R5U2998q Pagel 101M ..,arrW UserlDmesslW ggNsoftHVACWW-18xw Calc=WB FroriDoorfaces: E Entire House 1804 25329 29372 0 1090 Other equip loads 0 0 Equip. @. 0.95 RSM 28021 Latent cooling 6866 1804 25329 34887 n ingn TOTALS 8aldfdaUo values have been manuafly ovonfdden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft" 2021-Apr-1515:3220 .rn..•ie.e» w.ec«An FSgttSUWSUriversal202121A.05R5U29964 Paget ACM _s,er{pogmeristWrighlsoftFNACIMW-18np CaIc=MJB FrortDoortaws: E r -�- wrightsofts Project Summary Entire House Project Information For. MW-18 3613 GROVE CT, FORT -PIERCE, FL 34951 Notes: Job: Date: Apr 14, 2021 By. Desigh Information Weather. St Lucie Co Intl, -FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 72 OF Design TD 29 OF Design TD ' 18 OF Daily range L Relative humidity 52 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure .23649 Btuh Structure 26182 Btuh Ducts 1681 Btuh Ducts 3190 Btuh Central vent (0 cfm) 0 Btuh 'Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Eguipmentioad 25329 Btuh Use manufacturers data n Rate/swingg multipplier 0.95 Infiltration Equipmentsensib[a load 28021 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces -0 Structure 5459 Btuh Ducts 1407 Btuh Central vent (0 cfm) 0 Btuh HeatingCooling (none) 6866 Btuh Area (ft2) 1804 1804 Equipment latent load Volume (T) 17825 17825 Airchangdidhour 0.38 020 Equipment Total Load (Sen+Lat) 34887 Btuh Equiv AVF (cfm) 113 59 - Req.-total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1-041-230A** AHRI ref Coil CBA27UHE-048-230*++TDR AHRI ref 10259425 Efficiency 100-EFF Efficiency 13.0 EER,16 SEER Heating input 7.3 kW Sensible cooling 26950 Btuh Heating output 24817 Btuh Latentcooling 11550 Btuh Temperature rise 0 OF Total cooling 38500 Btuh Actual airflow 0 cfm Actual airflow 1090 cfm Airflow -factor 0 cfm/Btuh Airflowfactor 0.037 dm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 l BoldrdaUc values have been manua0y overridden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -rid- -wrightsoft• 2021-Apr-15153220 AfGyGA ��� PigHSdEe®Uriversa1202121AA5RSU29964 Paget .srsWr,tWAM merWWrgtboRHVAC4MW-18sw Calc=NUB FmrtDoorfares E Level I Job M Performed for: MW-18 3613 GROVE CT FORT PIERCE, FL 34951 CALCULATIONS Scale: 1 : 163 Page 1 RightSuitaO Universal 2021 21.0.05 RSU29964 2021-Apr-1515:33:35 uments\W rightsoft H VACWIW-18.rup • GH 0 HOMES MW-18 3613 GROVE CT FORT PIERCE, FL 34951