HomeMy WebLinkAboutAPPROVED Montero Front Door - FL15213_R4_AE_(b) Eval 15213.1R W R W Building Consultants, Inc.
BConsulting and Engineering Services for the Building Industry
C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Registry License No. 9813
Product
Category
Sub Category
Manufacturer
Product Name
Plastpro Inc.
Smooth / Wood Grain / White Wood Grain
Exterior
Swinging
Exterior Door
5200 W. Century Blvd.
Rustic /Mahogany
Doors
Assemblies
Los Angeles, CA
Series Fiberglass Door
Phone 440.969.9773
Inswing/Outswing -'Impact'
Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for
Plastpro Inc., based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of
Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and is in compliance with the 7th Edition (2020) Florida Building Code (FBC) structural requirements
excluding the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does
not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996
and FBC Sections 1609.1.2.2 & R301.2.1.2.1.
4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered
architect.
6. See drawing FL-15213.1 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard
TEL 2005-02-21-001 ASTM E330-02, ASTM E1996/1886-02
2. Drawing No. Prepared by
No. FL-15213.1 RW Building Consultants, Inc. (#9813)
3. Calculations Prepared by
Anchoring RW Building Consultants, Inc. (#9813)
4. Quality Assurance
Certificate of Participation issued by National Accreditation and
Management Institute, certifying that Plastpro Inc. is manufacturing
products within a quality assurance program that complies with
ISO/IEC 17020 and Guide 53.
Testing Laboratory Signed by
Testing Evaluation Lab.,lnc. Wendell W. Haney, P.E.
Signed & Sealed by
Lyndon F. Schmidt, P.E.
Signed & Sealed by
1111111a Lyndon F. Schmidt, P.E.
,� • y�GE N
• No 43409
"O
:%4 - STATE OF
0 •• .
�i1�11i1119� Lyndon F. Schmidt, P.E.
FL PE No. 43409
8/7/2020