HomeMy WebLinkAboutAPPROVED Holycross-CWS-FL16177 SH IMPACT WINDOW8100 PVC SINGLE HUNG IMPACT CWS-812 D BAT 06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE: 1:15 SHEET 1 OF 6 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.X O 30 3/16" MAX. SASH HEIGHT 63" MAX. OVERALL FLANGE HEIGHT 53 1/8" MAX. OVERALL FLANGE WIDTH 51 7/8" MAX. UNIT WIDTH 61 3/4" MAX. UNIT HEIGHT 26 7/8" GLASS DLO 45 1/16" GLASS DLO 26 13/16" GLASS DLO 47 11/16" GLASS DLO 48 3/8" MAX. SASH WIDTH A 6 B 6 GENERAL NOTES AND ELEVATIONS GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. 2. GLAZING OPTIONS: (SEE SHEET 2) 3. CONFIGURATIONS: "O/X". 4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. 7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT USED AT FIXED MEETING RAIL AND JAMB. 8. SERIES / MODEL DESIGNATION SH-8100. 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X = OPERABLE SASH, O = FIXED SASH 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION. 11. EXTERNAL WEEP SLOT = 1/4" x 1-1/4" LOCATED 4" FROM BOTH ENDS. TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS.....1 GLAZING DETAIL.................................2 SECTION VIEWS.................................3 EXTRUSIONS & B.O.M........................4 ANCHOR SCHEDULE & NOTES.........5 INSTALLATION DETAILS....................6 SINGLE HUNG - LARGE MISSILE IMPACT MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING 51-7/8" x 61-3/4" +/- 70 PSF LARGE MISSILE IMPACT C 6 A A BB 8/05/2020 Lucas Turner 2020.08.06 14:50:45 -05'00' 8100 PVC SINGLE HUNG IMPACT CWS-812 D BAT 06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE: 1:1 SHEET 2 OF 6 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.7/8" OVERALL INSULATED GLASS 1/8" ANNEALED OR TEMPERED 7/16" AIRSPACE 1/8" ANNEALED .090" PVB INTERLAYER 1/8" ANNEALED 5/16" LAMINATED GLASS FIXED LITE 47 PURFECT GLAZE "H" OR SIKAFLEX 552 71 14 48* SASH LITE 7/8" OVERALL INSULATED GLASS 1/8" ANNEALED OR TEMPERED 7/16" AIRSPACE 5/16" LAMINATED GLASS 1/8" ANNEALED .090" PVB INTERLAYER 1/8" ANNEALED 47 PURFECT GLAZE "H" OR SIKAFLEX 552 14 48* 12 23 GLAZING DETAILS * SETTING BLOCKS PER FBC 2411.3.3.1 QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER 1/2" GLASS BITE 1/2" GLASS BITE 8/05/2020 8100 PVC SINGLE HUNG IMPACT CWS-812 D BAT 06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE: 1:2 SHEET 3 OF 6 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.6 73 74 SECTION A-A SECTION B-B NOTE: LEFT SIDE SHOWS FIXED SECTION VIEW, RIGHT SIDE SHOWS SASH SECTION VIEW. 1 14 54 9 8 10 53 30 3 45 32 4 12 451332 14 14 14 14 32 32 32 32 24 48 62 65 66 19 INTERIOR 2 18 54 39 2827 NOTE: ITEMS NOT SHOWN FOR CLARITY: 20, 25-26, 36-37, 44, 51-52, 55-56, 64, 67-68 636665 62 71 72 SECTION VIEWS INTERIOR 45 53 3827 23 32 70 8/05/2020 8100 PVC SINGLE HUNG IMPACT CWS-812 D BAT 06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE: 1:2 SHEET 4 OF 6 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.LINE ITEMS NOT USED: 5, 7, 11, 15-17, 21-22, 29, 31, 33-36, 41-43, 46, 49-50, 55, 57-61, 69 REINF., IMPACT HOOK - 1112 7/8" 9/16" 73 1 2 3 71 810 20 913 19 12 72 PVC SASH STOP - 6025 7/8" 1 5/16" 1/16" 14 CORNER WELD (ALL SIDES) 1:8 FRAME CORNER CONSTRUCTION FIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME 1:8 37 BOM AND EXTRUSIONS NOTE: ALL ALUMINUM EXTRUSIONS ARE 6063-T6 UNLESS OTHERWISE NOTED. 18 23 1/16" IMPACT HOOK S-1577 5" 7/8" 1 5/16" 1/16" 6 4 REINF. H-2123 1 3/16" 1 5/8"1/16" 3/4" 15/16"1/16" PVC SASH PULL RAIL/STILE H-6223 PVC SASH MTG RAIL H-6224 PVC FRAME FLANGE H-6222 PVC SASH RAIL/STILE H-6225 1 15/16" 1 5/8"1/16" 2 3/16" 1 5/8" 1/16" 3 1/8" 2 3/4" 1/16" PVC SCREEN SUPPORT S-6227 PVC SCREEN CATCH S-6226 PVC GLAZING BEAD S-6237 REINF. S-2129 REINF. SASH MTG RAIL H-2124 1 1/16" 1/4" 1/16" 1 1/16" 7/16" 1/16" 1" 5/8" 1/16" 5/8" 5/16" 7/8" MTG RAIL H-2121 1 9/16" 2 1/8" 13/16" 1 1/8" PVC MTG RAIL COVER S-6228 ITEM PART # DESCRIPTION MATERIAL 1H-6222Main Fr., SH, w/Flg., PVC, Head Vinyl 2H-6222Main Fr., SH, w/Flg., PVC, Sill Vinyl 3H-6222Main Fr., SH, w/Flg., PVC, L. Jb.Vinyl 4H-6222Main Fr., SH, w/Flg., PVC, R. Jb.Vinyl 6S-1577Impact Hook Alum 8H-6224Sash Meet. Rail, PVC Vinyl 9H-2124Reinf. Sash Meet. Rail Alum 10 H-6223 Sash Bottom Rail, PVC Vinyl 12 H-6225 Sash Side/Top/Bot. Rail Vinyl 13 S-2129 Reinf. S.B.R./S.S.R 14 S-6237 Glz. Bd., 7/8"Vinyl 18 S-6226 Scrn. Adapt., w/Nib, PVC, Horiz.Vinyl 19 S-6227 Scrn. Adapt., PVC, Vert.Vinyl 20 S-6025 Sash Stop / Filler, PVC, Vert.Vinyl 23 H-2123 Reinforcement, SBR Alum 24 Balance 25 P-3059 Sash Cam, PVC Plastic 26 P-3046 Take Out Clip SS 27 P-3783 Lock, Impact, PVC 28 P-4069 Keeper, Impact, PVC Zamac 30 P-3215 Weep Cover w/ Flap Plastic 32 P-3429 Wstp., 0.270 x .187 back FinSeal, Gray 37 P-4638 #8 x 2-1/2 PH Mod. Truss, Type A, TEK 2 Steel 38 P-3768 #8 x 0.625 Ph PH SMS Steel 39 P-4051W #8 x 1.250 Ph FH TEK, Wht.Steel 40 P-4264W #8 x 3/4 FH PH w/#6 Head, TEK, Wht. Steel 44 P-3342 Seam Sealer, SM-5504 45 P-5588 Cap Plug, 1/2" Hole Nylon 47 P-3438 Sikaflex 552 or Purfect Glaze "H" 48 P-5615 Set. Blk., 85 Dur., 1/8" x 1" x 2" Lg. Rubber 51 P-3881 Temporary Lbl. (NFRC/DP) 52 P-3613 CWS Lbl. (logo) 53 Sash SEE SHEET 2 54 Fixed SEE SHEET 2 56 P-3281 Spacer 62 P-3218 Screen Frame, Horiz.Alum 63 P-3218 Screen Frame, Vert.Alum 64 P-3321 Screen Frame Corner Key Plastic 65 P-3581 Screen Cloth, 18 x 16 Fiberglass Fiberglass 66 P-3228 Screen Spline, .155 Dia., Blk.Vinyl 67 P-3029 Screen Pull Tab Alum 68 P-3033 Screen Spring, SS SS 70 P-4959 Wstp., 0.270 x .187 back FinSeal, Gray 71 H-2121 Alum. Fixed Rail Alum 72 S-6228 Cover, Fixed Rail Vinyl 73 S-1112 Reinforcement, Impact Hook Alum 74 P-3541 #8 x 1/2", Pan Head, TEK Steel PARTS LIST 8/05/2020 8100 PVC SINGLE HUNG IMPACT CWS-812 D BAT 06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE: 1:15 SHEET 5 OF 6 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.X O SEE NOTE 2 INSTALLATION ANCHOR (TYP.) 6" MAX. (TYP.) 6" MAX. (TYP.) ANCHOR LAYOUT - (FLANGE) NO ANCHORS REQUIRED IN SILL 17" MAX. O.C. (TYP.) 4" (TYP.) 4" (TYP.) 10 1/2" MAX. O.C. (TYP.) ANCHOR SCHEDULE AND NOTES NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. NO ANCHORS REQUIRED IN SILL. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS) 10 1/2" MAX. O.C. (TYP.) 4" (TYP.) MTG RAILLC 8/05/2020 8100 PVC SINGLE HUNG IMPACT CWS-812 D BAT 06/18/12 SHEET DESCRIPTION: DRAWN BY: DATE: DWG #: REV.: SCALE: 1:2 SHEET 6 OF 6 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED INTHIS DRAWING IS THE SOLEPROPERTY OF CUSTOM WINDOWSYSTEMS, INC. ANYREPRODUCTION IN PART OR AS AWHOLE WITHOUT THE WRITTENPERMISSION OF CUSTOM WINDOWSYSTEMS, INC IS PROHIBITED.VERTICAL SECTION TYPICAL SILL ANCHORAGE A 6 B 6 HORIZONTAL SECTION TYPICAL JAMB ANCHORAGE INSTALLATION DETAILS TYPICAL HEAD ANCHORAGE SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.)3/16" ITW TAPCON 1-1/2"1-1/8" HOLLOW OR GROUT-FILLED CMU (117 PCF MIN.) 3/16" ITW TAPCON 1"2" CONCRETE (2.85 KSI MIN.)3/16" ELCO ULTRACON 1"1" GROUT-FILLED CMU (ASTM C-90)3/16" ELCO ULTRACON 1-1/4"2-1/2" 2X MIN. SOUTHERN PINE (G=0.55)3/16" ITW TAPCON OR ELCO ULTRACON 1-3/8"7/8" 2X MIN. SOUTHERN PINE (G=0.55)#10 WOOD SCREW 1-3/8"7/8" 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KWIK-FLEX OR ITW TEKS SELF-DRILLING SCREW FULL THREAD THRU 0.060"7/16" 1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.) #10 GRADE 5 SELF-TAPPING / DRILLING SCREW FULL THREAD THRU 0.125"7/16" TABLE 1: APPROVED INSTALLATION FASTENERS MIN. EMBEDMENT SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 MIN. EMBEDMENT SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 PERIMETER SEALANT BY INSTALLER INSIDE AND OUT PERIMETER SEALANT BY INSTALLER INSIDE AND OUT PERIMETER SEALANT BY INSTALLER INSIDE AND OUT PERIMETER SEALANT BY INSTALLER INSIDE AND OUT SEALANT BEHIND FLANGE BY INSTALLER SEALANT BEHIND FLANGE BY INSTALLER SEALANT BEHIND FLANGE BY INSTALLER INSTALLATION ANCHOR SEE TABLE 1 INSTALLATION ANCHOR SEE TABLE 1 SUBSTRATE BY OTHERS SEE TABLE 1 SUBSTRATE BY OTHERS SEE TABLE 1 SUBSTRATE BY OTHERS SEE TABLE 1 FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: - MIN. 1/4" FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED INSIDE AND OUT, FULL PERIMETER, BY INSTALLER. - PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS. C 6 HORIZONTAL SECTION BOX FRAME INSTALLATION HEAD AND SILL SIMILAR FOR BOX INSTALLATION MIN. EMBEDMENT SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 CONTINUOUS DOUBLE 3/16" BEADS OF TREMGLAZE U1600 SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND BUCK BY INSTALLER. 1/4" MAX SHIM 1/4" MAX SHIM 1/4" MAX SHIM 8/05/2020