Loading...
HomeMy WebLinkAboutENERGY CALCS & MANUAL J - 10 ECUADOR CT FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type�1432.0 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1224.00 ft2 b.Frame-Wood,Adjacent R=11.0 208.00 ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 11.Ceiling Types (1783.0 sgft.) Insulation Area a. Under Attic(Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade(ft2) 1753 b.Knee Wall(Vented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft2) 0 c.NIA R= ft2 7. Windows(151.4 scift.) Description Area 12.Ducts R ft2 a. U-Factor: Sgl,U=1.02 111.36 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 195 SHGC: SHGC=0.29 b. U-Factor. Sgl,U=1.11 40.00 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor. NIA ft2 SHGC: 14.Heafing systems kStu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Area c. U-Factor.(AVG) N/A ft2 15. Hot water systems SHGC(AVG): NIA a.Electric Cap:40 gallons 9. Floor Types (1753.0 sgft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. NIA R= ft2 None c.N/A R= ft2 16.Credits None Glass/Floor Area: 0.0$6 Total Proposed Modified Loads: 49.38 PASS Total Baseline Loads: 50.69 i hereby certify that the plans and specifications covered by Review of the plans and Q,JOE q this calculation are in compliance with the Florida Energy specifications covered by this �y p Code. calculation indicates compliance `+' with the Florida Energy Code. W PREPARED BY. Before construction is completed 5 `f DATE: 1-'12-2 129 this building will be inspected for (f compliance with Section 553.908 I hereby certify that this building,as designed, is i mpliance Florida Statutes. with the Florida Energy Cod , '��WS OWNER/ G N BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DININGIGREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 fF ____ 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' _ 0 1 0 4 Slab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft' _- 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY t ft 0 36 fF _ 0 1 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge lnsulatio BEDROOM 2 12 ft 0 180 ft2 — 0 1 0 7 Slab-On-Grade Edge lnsulatio DINING/GREAT 50 it 0 588 ft2 — 0 1 0 8 Slab-On-Grade Edge lnsulatio KITCHEN lift 0 209 f12 _- 0 1 0 9 Slab-On-Grade Edge lnsulatio BATH 5 It 0 50 ft2 0 1 0 10SIab-On-Grade Edge lnsulatio HALL 1 it 0 25 ft2 ___ 0 1 0 11Slab-On-Grade Edge lnsulatio FOYER 9 ft 0 92 ft2 0 1 0 12SIab-On-Grade Edge lnsulatio BEDROOM 3 14 ft 0 169 f12 ___ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic(Vented) LAUORY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft. 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall(Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE=>SW Exterior Concrete Block-Int Ins671ASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 _2 SW=>NE Exterior Concrete Block-Int InsWASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 NW=>SE Exterior Concrete Block-Im InseIIASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 4 NE=>SW Exterior Concrete Block-Int Ins&ASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 NE=>SW Exterior Concrete Block-Int Insul M.BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 6 NE=>SW Exterior Concrete Block-Int InsBlEDROOM 2 4.1 12 0 8 0 96.0 ft- 0 0 0.3 0 7 SW=>NE Exterior Concrete Block-Int InsMINING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.3 0 - 8 NW=>SE Exterior Concrete Block-Int Ins(RINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 _9 SW=>NE Exterior Concrete Block-Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 10 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.3 0 _11 SE=>NW Exterior Concrete Block-Int Insul FOYER 4.1 8 0 8 0 64.0 ft- 0 0 0.3 0 12 SW=>NE Exterior Concrete Block-Int Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 13 NE=>SW Exterior Concrete Block-Int lnsBEDROOM 3 4.1 13 0 8 0 104.0 ft- 0 0 0.3 0 14 SW=>NE Exterior Concrete Block-Int Ins81EDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 15 N=>S Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang U # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft2 I It 0 in 1 It 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft' 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft- 1 ft 0 in 1 ft 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 ft 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 162 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft' 806 ft' 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15 34.8 kBtulhr cfrn 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name Svstem Model# Collector Model# Area Volume FEF None None ft= DUCTS / —Supply— —Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft' Attic 55 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e T]hermostar[t:'JN rx]] r Ceiling Fans:[X� (X� [X� [[XXJJ Be Healing l l Jan l l Feb l�J Mar Apr L 1 May [ ]Jun [ )Jul [ ] Oct Nov Dec Aug l J Sep Oct Nov Dec Heating I )Jan [ ]Feb IXl Mar lI 11 I 1 Jun I 1 Jul [ 1 Aug ll 11 Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WO) PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bs/sq.fL 0 ft' Oft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(81bs/sq.ft. ft' it 0.3 MASTER BATH Default(8 lbs/sq.ft. ft' It 0.3 M.BATH Default(8 lbs/sq.R ft' ft 0.3 LAUDRY Default(8 lbs/sq.1L ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.fL ft- ft 0.3 FOYER Default B lbs/sq.ft. ft' ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 6 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE W INDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street THE WINDSOR Permit Office: ST.LUCIE COUNTY City,state,Zip: FT.PIERCE,FL, Permit Number. Y U Owner: Jurisdiction: w x Design Location: FL,Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceilin soffit the insulation and any g . yaigaps In the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa . Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind ninino and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a.In addition,inspection of log walls shall be in accordance with the provisions of[CC-400. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR. FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1224.00 ft2 b.Frame-Wood,Adjacent R=11.0 208.00 ft' 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.WA R= ft2 5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ft2 6. Conditioned floor area(ft2) 1753 b.Knee Wall(Vented) R=19.0 30.00 ft2 c.NIA _ z 7. Windows*' Description Area 12.Ducts,location&insulation level R R ftz a. U-Factor. Sgl,U=1.02 111.36 ft2 a.Sup:Attic,Rat Attic,AH:Attic 6 195 SHGC: SHGC=0.29 b. U-Factor. Sgl,U=1.11 40.00 ft' SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a.Central Unit 34.8 SEERA5.00 SHGC: d. N/A SHGC:: 14.Heating systems kBtu/hr Efficiency SHGC:Area Weighted Average Overhang Depth: 2.850 it a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15.Hot water systems a.Electric Cap:40 gallons a. U-Factor(AVG): WA ft�SHGC(AVG): N/A b. Conservation features EF:0.97 9. Floor Types Insulation Area None a.Stab-On-Grade Edge Insulation R=0.0 1753.00 ft' Credits(Performance method) None b.WA R= ft2 c.N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building krt Sp9 Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed kF,,'' based on installed Code compliant features. Builder Signature: f te: Add ressofNewHome:`K3 �CVCt \_ �C- LNl,-y City/FL Zip: ���2tCQ1 `Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. '*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 ® Project Summary o te1 wrightsoft Entire House By. QUICK CALLS, INC. 317 ST LUCIE LN.,Fr..PIERCE,FL 34946 PF re:772-466-6799 Fax M466£796 Emil:QU1CKCALCS@40LCOM Promect Information Will For. WYNNE DEVELOPMENT THE W INDSOR.FT.PIERCE,FL Notes: Design Information Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gnlb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Btuh Ducts 9337 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) , (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 27734 Btuh Use manufacturer's data n Rate/swingg multipplier 0.95 Infiltration Equipmentsensibleload 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Ducts 2546 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cooling (none) Area(ft2) 1753 1753 Equipment latent load 5041 Btuh Volume(ita) 16478 16478 Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 29511 Btuh Equiv.AVF(cfm) 104 55 Req.total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carder Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A 030 Cond 25HBC536XO30 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47'F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 din Actual airflow 1160 cfin Airflow factor 0.042 cfm/Btuh Airflowfactor 0.045 cfmBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=36 OF Backup: Input=7kW, Output=23009 Btuh,100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrjghr oft' 2021-JaM11213:18:18 •�-^%^^— RighSufe®Uriversa1201919.021 RSUC8101 Pagel ...Doame NWrigHsoft HVAQWYNNE-THEWINDSORnn Calc=MJ6 Frordl)oorfaces:N wrightsoft. Right-J®Worksheet Job` Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 P1ore:772-466-6799F=T12466-S796 E.iI:QJrKCP.LCS@p.OL.GDM 1 Room name Enfire Hose BEDROOM 2 EVoad%all 207.6 ft 41.0 ft 3 Room tolght 9A ft d 9.4 ft heaYmol 4 Room dimeraons 14.0 x 20.0 ft 5 Roan area 1753.0 R 280D fF Ty Construction U-value Or HTM Area (fth Load Area (ft� Load number (BWMF-'F) (BWh" or perimeter M (BWh) a penmeW (T (BWh) Heat Ccol Gross NIPS Heat Cool Gross N1P5 Heat Cod 6 VL1344ac 0.143 In 4.00 255 649 596 2386 1517 66 66 263 167 IA-dw 1270 n 3556 34.77 15 0 533 522 0 0 0 0 4A5-2on 0.770 n 2156 1931 38 0 815 730 0 0 0. 0 W 13A4= Q143 m 4.00 2,55 27 27 106 68 0 0 0 0 11 13AA= 0.143 a 4.00 2.55 141 100 400 255 0 0 0 0 I--G 1Aclan 1270 a 3556 97.06 20 1 711 1741 0 0 0 0 �--D 11DO 0390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13AA= 0.143 se 4D0 255 27 27 106 68 0 0 0 0 VN 13A4= 0.143 s 4.00 2.55 536 530 2121 1349 188 188 -753 479 I—C 7Ac1an 1270 s 3556 34.77 6 6 213 209 0 0 0- 0 13A4= 0.143 w 4A0 255 320 255 1022 649 132 108 432 275 l4dom 12n w 3556 5453 12 1 415 636 12 1 415 636 1A-vl= 1270 w 3556 54.53 12 1 427 654 12 1 427 654 4AS2om 0.770 w 21M 45.63 41 2 880 1862 0 0 0 0 P 12C-Ow 0A91 - 2.55 128 254 254 647 326 0 0 0 0 C 16A30md 0.032 - 0M 232 1753 1753 1571 4067 280 290 261 650 F 224V 02W - 2759 0A0 1753 208 5748 0 280- 41 1135 0 6 c)AEDe rsiw 3971 1 488 Emzlope losstgain 18331 15285 3676 3349 12 a) hfilt tlon 3211 905 729 205 b) Room�blabon 0 0 0 0 13 blt m low O=pants@ 230 1 230 0 0 Apdiarcelother 0 0 Subtotal(11nes6tol3) 21542 16420 4405 3554 I-Medemalload 0 0 0 0 Lasstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 21642 16420 44052056 3554 15 Dudloads 29% 57% 6191 9337 29% 57% 1 2021 Total room Iwd 27734 25757 5671 5575 Airrequired(dm) 1160 1160 237 251 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Amac, -pW!„M,, 2021. 1213:18:18 —ck Po9--THE iNos p-,p 7CaIc=M1 RSU08101 ...DxnerOlWrigt�ft FNAQWYNNE-TFIE WINIOSORnp CaIc=MIB Fnx6Doorfaoes:N Page wrightsoft° 02ighW@ Worksheet .lob Entire House By. By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FL PIERCE,FL 34946 PhDm:772-466-M9 Fax:772-466-6796 Emil:QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 F)yosed V41 0 It 9D ft 3 Room height 9A It hea7mol 9.4 t heatbool 4 Room dimensons 7.0 x 9A It7A x 9.0 It 5 Roomares 63.0 [F 63.0 ff Ty Condon U-value Or HTM Ala Load number (BWhtlUl) (BWhRn or perimeter �(t) (BWh) orpenme (to (Btuh) Heat Cool Gross NLPS Heat Cool Gross NIPS Heat cool 6 lq! 13A-0as 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 IF--CG 1Actom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 1931 0 0 0 0 0 0 0 0 W 13A-0ors 0.143 m 4A0 255 0 0 0 0 0 0 0 0 11 y/- - 13A4ors 0.143 a 4D0 2S5 0 0 0 0 0 0 0 0 II----DG 1Aclw 12M a 3556 87A6 0 0 0 0 0 0 0 0 11DO 0.39D a 1022 1131 0 0 0 0 0 0 0 0 w 13AAoa 0.143 se 4.00 255 0 0 0 0 0 0 0 0 Vj/ 13A4ors 0.143 s 4A0 2.55 0 0 0 0 85 85 339 215 t-C 1A-don 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A-0as 0.143 w 4110 255 0 0 0 0 0 0 0 0 1A-clan 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1Acian 1270 w 35M 54M 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21BS 45.63 0 0 0 0 0 0 0 0 P 12C-0sv om 255 128 0 0 0 0 0 0 0 `0 c 16A30md 0.032 - ow 2.32 63 63 56 146 63 63 56 w F 22A-tpl 0.989 - 27M 0.00 63 0 0 0 63 9 249 0 6 c)A1D emlison -10 -28 Emlope loss'gain 56 136 644 334 12 a) hiltration 0 0 160 45 b) Roomeentialim 0 0 0 0 13 hhvnal gains: Orwpan6@ 230 0 0 0 0 AWianmsbther 0 0 Subtolal(lines(51113) 56 136 804 379 Lesed�malload 0 0 0 0 Lestranser 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 804 379 15 Duct loads 29q sm 16 77 29% 231 216 Total room load 73 214 1036 595 Air required(dm) 3 10 43 27 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed ��wrigt�7t,oR- 20214a 1213:18:18 ...Oocner6lWrigtboRF1VACWYYNNE-THE WINDSORnp CaIc=MIB Fror¢pooriaces N Page 1 i wrightsoft° Right-J®Worksheet Job: Entire House Data: QUICK CALLS, INC. By. 317 ST.LUCIE LN.,Fr.PIERCE,R34946 Phone:772-466-6799 Fax 772-466-6796 Email:OUICKCALCS AOL.COM 1 Room name MRATH KITCHEN 2 Exposed vall 8.0 It 8.0 It 3 Room height I 9.4 It heatbool 9.4 ft heat/mol 4 Room dimensions I 7.0 x 8.0 ft 1.0 x 172.0 ft 5 Room area 66.0 fF 172.0 IF Ty Conduction U-value Or HTM Area (fF) Load Area (� Load number (BWhV2F) (BWht?) or perimeter (ft) (BWh) or perimeter M (Bluh) Heat Cool Gros NIPS Heat Coal Gros NFIS Heat Cool 6 vI 13A-0o 0.143 n 4.00 2S5 0 0 0 0 0 0 0 0 L�CG ¢1Ac1om 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-20m 0.770 n 2156 1931 0 0 0 0 0 0 0 0 W 13A-0ors 0.143 no 4.00 2.55 0 0 0 0 0 0 0 0 11 ---G 13A4os 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 I-G IAclom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 II--DODO 11DO 0.390 a 1092 11.31 0 0 0 0 0 0 0 0 w 13A-0ors 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 t13A-0ocs 0.143 s 4.00 2.55 75 69 277 176 0 0 0 0 -G 1Actom 1270 s 35.56 34.77 6 6 213 209 0 0 0 0 13A-4os 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A�clom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G lxdom 1270 w 35.561 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 - 2.65 128 0 0 0 0 75 75 192 96 C 16A-Wmd 0.032 - 0.90 232 56 56 50 130 172 172 154 399 F 22A-tp1 0.989 - 27.69 0.00 56 8 222 0 172 8 222 0 6 c)AED ex um -381 Envelopeloss/gain 762 477 567 462 12 a) Infiltration 142 40 0 0 b) Roomventiation 0 0 0 0 13 Intemalgairs: OoaipanIs@ 230 0 0 0 0 Appliance4other 0 0 Subtotal(lines6 to 13) 904 517 567 462 Lesextarnalload i 0 0 0 0 Less transfer 0 0 Redistribution 0 0 0 0 0 0 14 Subtotal904 577 567 462 15 Ductloads I 29% 57% 260 294 29% 57% 163 263 Total room load j 1164 811 730 725 Airrequired(Um) I 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed '✓r{t wr�96Lso1't^. A ... Rigtt lriv 01919.021 2021Jan-1213:18:18 Camris\WngltroftFNAQW7NNE-THEWINDSORrLp CaIc=N8 FrormDoorfaws:N Page 1r�wrightsoft' Right-M)Worksheet Job: Entire House pate: By. QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr.PIERCE.FL 34946 Ptore:772-066-6799 Fax T72466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM2 2 BposBdwall 51) ft 42.6 ft 3 Room height 9A ft heel 9.4 ft heaV000l 4 Room dunensas 9.0 x 5A ft 1.0 x 204.0 ft 5 Room area 45.0 fl= 204A fF ry Load mmb�er n (BUhAlk'n-Nalue or (BwfMO or penm�eter (it) (Bb�ih) or pedmeeler (ft) (BuM Heat Cool Gros N/P5 Heat Cod Gross N/P5 Heat Cool 6 13A4= 0.143 n 4.00 255 47 47 188 120 132 132 527 335 1AcIom 127M n 35.% 34.77 0 0 0 0 0 0 0 0 4A52om 0.770 n 21M 1931 0 0 0 0 0 0 0 0 w 13A-0ots 0.143 m 4A0 2.55 0 0 0 0 27 27 106 68 11 13A-0as 55 0.143 a 4A0 2 0 0 0 0 85 65 259 164 I—G IA-dom 1270 a 3556 97.06 0 0 0 0 20 1 711 1741 I--0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4as 0.143 se 4A0 255 0 0 0 0 27 27 106 68 lR/ -13A4o s 0.143 s 4A0 2.55 0 0 0 0 132 132 577 335 1—C 1A-dom 1270 s 3556 34.77 0 0 0 0 0 0 0 0 1pl 13A4as w 4.� 5 0 0 0 0 0 0 0 0 el L��GGG to- an 1270 1270 w 3556 s4,a.53 0 0 0 0 0 0 0 0 tAcIom 12M w 36M 54M 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 285 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 090 2.32 45 45 40 104 204 204 183 473 F 22A-yN 0989 - 27.S9 0.00 45 5 138 0 204 43 1179 - 0 6 c)Ame=irsion -17 -99 EnvelopeloWgain 367 207 3599 3085 12 a) Infiltration 89 25 758 214 b) RoomverNlation 0 0 0 0 13 Immal gain O=paMs@ 230 0 0 0 0 Applianoeslother 0 0 Subbolal(lirres6t)13) 456 232 4357 3299 Les elO�mal load 0 0 0 0 Lestarefer 0 0 0 0 Redistibubw 0 0 0 0 14 Subtotal 456 232 4357 3299 15 Dud loads 29% 57% 131 132 29% 57% 1252 1876 Total room load 587 364 5609 5175 Airrequired(dm) 25 16 235 233 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. wrA9lf oii` 2021.18 1213:18:18 A" k RigltSute@Uriversal 201919.021 RSU08101 Page 4 ...DDwTwts\WAgh%oftHVAQWYNW-TFEWINDSORAp Calc=M1B Fror2Doorfaces N t}I wrightsoft° Right-M Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LN..FF..PIERCE,FL M946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 Exposedwall 18.0 It 13.0 It 3 Room height 9.4 ft healloxl 9.4 ft healloxl 4 Room dimensions 1.0 x 92.0 ft 7.0 x 6.0 ft 5 Room area 92.0 IF 42.0 IF Ty Construction U-value Or HTM Area (ft) Load Area in Load number (BWWF) (BWhXF) or perimeter (ft) i (BWh) or perimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 y/ 13A4as 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 I�-CG 1Acicm 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0. W 13A4ors 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 17 13A4= 0.143 a 4.00 2S5 56 35 142 90 0 0 0 0 1Aolom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 11DO 02W a 10.92 1131 21 21 229 238 0 0 0 0 W 13A4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 13A4ors 0.143 s 4.00 2.55 0 0 0 0 56 56 226 144 t-C tAclom 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A-00cs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1270 w 35S6 54.53 0 0 0 0 0 0 0 0 1A-clom 1270 w 35-%j 54.53 0 0 0 0 0 0 0 0 4 2. 0.770 w 21 g 45.63 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 2.55 128 113 113 287 145 66 66 168 84 C 16A30md 0.032 - 0.90 2.32 92 92 82 213 42 42 38 97 F 22A-Ipl 0.989 - 27.69 0.00 92 18 498 0 42 13 360 0 f i I 6 c)AED exnnsion 49 1 -24 Envelopeloss(gain 1239 637 791 301 12 a) Infiltration 107 30 107 30 b) Roomvenfilation 0 0 0 0 13 Intemalgains: Ocupants@ 230 0 0 0 0 Appliano-slother 0 0 Subttal(linei 6to13) 1346 667 898 331 Lesexdemalload 0 0 0 0 Lestran4er 0 0 0 0 Redistribution 0 0 14 Subtotal1346 667 898 3311 151 Duct loads 29% 57% 387 379 29% 57o/ol 258 188 Total room lcad 1733 1047 1156 520 A%'qr' ired(dm) 72 47 48 23 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 2021-Jan1213:18:18 RigttTHEWI b SOP;.rup Caf9.021 RSU08101 '�A ...Doameris\Wngitmft HVAC\WYNNE-THE WINOSORnp CaIc=N18 FrorR Doorfaces:N Page 5 F� wrightsoft° Right-J®Worksheet Job: Entire House By By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKC4LCS@AOL.COM 7 Room name GREAT/DINING Rwm7 2 Emosdwell 50.0 it 13.0 It 3 Room height 9.4 ItheaNmol 9.4 ItheaNmol 4 Room tlimenso0s 1.0 x 567A ft 73.0 x 13.0 It 5 Room area 567.0 ft2 169.0 ft2 Ty Construction U-value Or HTM Area (n Load Area (n Load number (BWh/F2F) (BWhdt or perimeter (it) (BWh) or perimeter (ft) (B1uh) Heat I Cool Gross NIPS Heat Cool Gross NIP/8 Heat Cool 6 Vjl 13A-0ocs 0.143 n 4.00 2.55 282 244 978 622 122 107 429 273 tH--GG 1Ac1om 127C n 35.56 34.77 0 0 0 0 15 0 $33 522 4A5-2om 0.770 n 2156 1931 38 0 815 730 0 0 0 0 w 13A-0ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 17 13A-0as 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 e 3556 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 1092 11.31 0 0 0 0 0 0 0 0 w 13A4o s 0.143 se 4A0 2.55 0 0 0 0 0 0 0 0 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A-4ors 0.143 w 4.001 2.55 188 147 589 375 0 0 0 0 tAcMm 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G 1A-dom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4A5-20m 0.7 c w 2156 45.63 41 2 880 1862 0 0 0 0 P 12C-0sx 0.091 - 2M 128 0 0 0 0 0 0 0 0 c 16AJ0md 0.032 - 0.90 2.32 567 567 508 1315 169 169 151 392 F 22A-tpi 0989 - 27.69 0.00 567 50 1395 0 169 13 360 0 61 c)AED esnuson 307 -700 Envelopeloss/gain 5154 521C 1474 1086 12 a) Infiltration 889 251 231 65 b) Room ventlabon 0 0 0 0 13 Internal gains: 0¢upants@ 230 0 0 1 230 Applianceslother 0 0 SubbYal lines 6to 13) 6043 5461 1705 1381 Lese)damal load 0 0 0 0 Lesstansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6043 5461 1705 1381 151 Duct loads 29% 57% 1737 3105 29% 57% 490 785 Toirtal room load 2195 2167 Arequired(cfin) 7780 8566 325 386 92 98 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed .9 h wrlghLsof[- 2021-Jan1213:18:18 RigttTHF WINDSO aw Cal9.021 RSU08101 ...Docuner6\WrigFL�oRHVAC\WYNNE-i}IE WINDSORnp Calc=MlB Frord Dooncoes:N Page .p�. wrightsoft° Duct System Summary �: Entire House BY QUICK CALCS, INC. 317 ST.LUCIE LN,Fr.PIERCE.FL 34946 KOM:772-46&6799 Fax 772-4666796 r.U:QUICKCALCS@AOL.CDM Project • • For. WYNNE DEVELOPMENT THE W INDSOR,FT.PIERCE,FL Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100It 0 in/100ft Actual airflow 1160 clim 1160 cfm Total effective length(TEL) 0 It SupplyDetail Table Htg Clg Design Diam HxW Duct Actual Ftg.Egv Name (Btuh) (dim) (chn) FR (in) (in) Mat Ln(it) Ln(ft) Trunk BATH h 364 25 16 0 0 OxO ShMt 0 0 BEDROOM c 2788 119 126 0 0 Ox0 ShMt 0 0 BEDROOM h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM,A c 2788 119 126 0 0 0x0 ShMt 0 0 ENTRY h 1047 72 47 0 0 0x0 ShMt 0 0 GREATAINLNG C 2855 108 129 0 0 OxO ShMt 0 0 GREATroIMNG-A c 2855 108 129 0 0 Ox0 ShMt 0 0 GR.AVDINING-B C 2855 108 129 0 0 Ox0 ShMt 0 0 KITCFEN C 725 31 33 0 0 0x0 ShMt 0 0 LAUNDRY h 520 48 23 0 0 Ox0 ShMt 0 0 M.BATH h 811 49 37 0 0 Ox0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 Ox0 ShMt 0 0 Racm7 c 2167 92 98 0 0 Ox0 ShMt 0 0 wlc c 214 3 10 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam HxW Slud/Joist Dud Name Size(in) (dm) (cfm) (ft) FR (10m) (in) (n) Opening(in) MA Trunk rb1 OxO 1 1160 1160 0 1 0 0 0 Ox 0 ShMt wrightsOft- MgttSUtBOLW raa1201919.02 P I AC)Ck1RSUD8101 2021-J 121age ...DDwrertgWrigNwft FNAC\WYNNE-THEWINDSORAP Calc=Mk Frord Dwrfaces N ape