Loading...
HomeMy WebLinkAboutPROJECT SPECIFICATIONSREVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEG-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951 5.325 kW PV SYSTEMCODES AND STANDARDSWATTS RESIDENCEVICINITY MAPSHEET INDEXG-01COVER SHEETPROJECT SITEPROJECT DESCRIPTION:OWNERHOUSE PHOTOGOVERNING CODES :FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)NATIONAL ELECTRICAL CODE 2017 (NEC)ASCE 7-16A-01ROOF PLANS-01MODULE LAYOUTS-02ATTACHMENT DETAILS-02.2STRUCTURE CALCULATIONE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGSHEET SHEET DESCRITIONCOVER SHEETA-00NOTES AND DESCRIPTIONELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:DESIGN CRITERIA:WIND SPEED (ULT): 160WIND SPEED (ASD): 124RISK CATEGORY:IIEXPOSURE:CPROJECT SITESRACKING: UNIRAC STANDARD RAILATTACHMENT: FLASHKIT PRO (GABLE ROOF)QBASE LOW SLOPE MOUNT WITH ECURB (FLAT ROOF)S-01.1ARTIAL RESSURE AND MODULES EXOSURESUNPRO SOLAR4492 Eagle Falls Place,Tampa, FL 33619(866) 450-1012INSTALLERCastillo Engineering Services LLC620 N. Wymore Road, Suite 250, Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590ENGINEERWATTS, MINDY(N) 15x355 LG NEONR: LG355N1C-N5 (355W) MODULES(E) 27x335 LG NEON2: LG335NIC-V5 (335W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESSYSTEM SIZE:5.325 kW DC STCARRAY AREA #1:185.92 SQ. FT.ARRAY AREA #2:92.96 SQ. FT.EQUIPMENT SUMMARY (NEW)15 LG NEONR: LG355N1C-N5 (355W) MODULES15 ENPHASE: IQ7PLUS-72-2-US MICROINVERTERS6602 BAYARD RD,FORT PIERCE, FL 34951DS-01-08DATA SHEETSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLARENERGY CENTER CERTIFICATIONAUTHORITY HAVING JURISDICTION:ST. LUCIE COUNTYEQUIPMENT SUMMARY (EXISTING)27 LG NEON2: LG335NIC-V5 (335W) MODULES27 ENPHASE: IQ7-60-2-US MICROINVERTERSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED.,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS.STRUCTURE CALCULATIONATTACHMENT DETAILS-02.1S-02.3 System DescriptionThis system is a grid-tied, PV system, with PV generation consisting of42x355 LG NEONR: LG355N1C-N5 (355W) Modules with a combined STC rated dcoutput power of 14,910W. The modules are connected into 42 Enphase:IQ7PLUS-72-2-US microinverters. The inverter has electronic maximum powerpoint tracking to maximize energy captured by the PV modules. The inverter alsohas an internal ground fault detection and interruption device that is set todisconnect the array in the event that a ground fault that exceeds one ampereshould occur. The inverter has DC and AC disconnect integrated system and labelsare provided as required by the National Electrical Code.When the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used tocontribute to the power requirements of the occupancy. If PV power meets therequirements of the loads of the occupancy, any remaining PV power is sold backto the utility. When utility power is available, but PV power is not available,building loads are supplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramSection..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD OverCurrent Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUNO Unless Noted OtherwiseVIF Verify In FieldWP Weather ProofBatteryBATUtility meterUMGPGeneration PanelMDPMain Distribution PanelSoladeckSDNAVD North American Vertical datumMID Microgrid Interconnect DeviceREVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951NOTES ANDDESCRIPTIONSymbols:Abbreviations:66.93"40"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES···1926.502(D)(15)ALLOWABLE/DESIGN PRESSUREPSFDOWN PRESSURE126UPLIFT PRESSURE, 2 RAILS89LG NEONR:LG355N1C-N5 (355W)MODULESFOR HIP ROOF:ALLOWABLE/DESIGN PRESSUREPSFDOWN PRESSURE126UPLIFT PRESSURE, 2 RAILS89FOR FLAT ROOF: UM MDP ACDCBSD 52'.0"14'-11"48'-10"13'-7"130'-0"90'-1"130'-0"90'-1"SDREVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951ROOF PLAN1" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUN(E) UTILITY METER( N) SOLADECK (TYP.)(E) MAIN DISTRIBUTION PANEL(N) AC DISCONNECTEXISTINGDRIVEWAY1-STORYHOUSE(E) ENPHASE IQ COMBINER BOXBAYARD RD,ROOF PLAN WITH FIRE SETBACKSAND PROPERTY LINESA-01SCALE: 1/16" = 1'-0"1ROOF #1(10) LG NEONR: LG355N1C-N5(355W) MODULES(N) (15) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROOF #2(05) LG NEONR: LG355N1C-N5(355W) MODULESPOOLEXISTING MODULES 56'-2"58'-5"4'-0" TYP.9'-0" TYP.REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951MODULE LAYOUTS-01SCALE: 3/32" = 1'-0"1(E) BACK YARD(E) FRONT YARDMODULE LAYOUTGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 & 02.1 AND AS FOLLOWS FOR EACH WIND ZONE:2) EXISTING RESIDENTIAL BUILDING HAS AN ASPHALT SHINGLE & AFLAT ROOF WITH A MEAN ROOF HEIGHT OF 15 FT AND SYP 2"X4" ROOFTRUSSES SPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLARSYSTEM RETROFIT IS 22.6 & 4.8 DEGREES. CONTRACTOR TO FIELDVERIFY AND SHALL REPORT TO THE ENGINEER IF ANYDISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS.* I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED. CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERALAND UPLIFT FORCES AND EQUIPMENT DEAD LOADS.. *WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14' - 0"1' - 4"4' - 0"1' - 4"ZONE 1'4' - 0"1' - 4"4' - 0"1' - 4"ZONE 24' - 0"1' - 4"2' - 0"0' - 8"ZONE 32' - 0"0' - 8"2' - 0"0' - 8"MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 15 MODULESMODULE TYPE = LG NEONR: LG355N1C-N5 (355W) MODULESMODULE WEIGHT = 39.68 LBS / 18 KG.MODULE DIMENSIONS = 66.93"x 40" = 18.59 SFUNIT WEIGHT OF ARRAY = 2.13 PSFARRAY AREA & ROOF AREA CALC'SROOFROOF TYPEARRAYAREA(sq.Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZETRUSSSPACING#1ASPHALT SHINGLE185.92502.5936.9922.6°0°2"X4"24" O.C.#2FLAT92.96243.3338.204.8°0°2"X4"24" O.C.(20) FLASHKIT PRO ROOF ATTACHMENTS@ 48" & 24" O.C. MAX.(SEE SHEET S-02 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULES)(N) UNIRAC STANDARD RAIL (TYP,)LEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2e / 2 (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e / 3 (TYP)WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14' - 0"1' - 4"4' - 0"1' - 4"ZONE 1'XXXXZONE 2e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 2nXXXXZONE 2r4' - 0"1' - 4"2' - 0"0' - 8"ZONE 3e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 3rXXXXROOF #1TILT - 22.6°AZIM. - 0°SEE SHEET S-02.3 FOR SUPPORTING CALCULATIONS.FOR HIP ROOF:SEE SHEET S-02.2 FOR SUPPORTING CALCULATIONS.(11) QBASE LOW SLOPE ATTACHMENTS@ 48" & 24" O.C. MAX.(SEE SHEET S-02.1 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULES)ROOF #1(10) LG NEONR: LG355N1C-N5(355W) MODULES(N) (42) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROOF #2(05) LG NEONR: LG355N1C-N5(355W) MODULESEXISTING MODULESROOF #2TILT - 4.8°AZIM. - 0°FOR FLAT ROOF: 4'-0" TYP.9'-0" TYP.P1P2P3P4P5P6P7P8P9P10P11REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951ARTIAL RESSURE ANDMODULES EXOSUREPARTIAL PRESSURE AND MODULES EXPOSURES-01.1SCALE: #############12h2FOR NON-EXPOSED MODULES (FOR HIP ROOF)LEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 2e / 2 (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e / 3 (TYP)NOTE : PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.2h2DISTANCE : 0' - 10"0.5hDISTANCE : 7' - 6"- MISSING MODULEFOR EDGE MODULES (FOR FLAT ROOF)FOR NON-EXPOSED MODULES (FOR FLAT ROOF)2h2DISTANCE : 2' - 0"0.5hDISTANCE : 7' - 6"FOR HIP ROOF :FOR FLAT ROOF :ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS : 89 PSF(E) BACK YARD(E) FRONT YARDROOF #1(10) LG NEONR: LG355N1C-N5(355W) MODULESROOF #2(05) LG NEONR: LG355N1C-N5(355W) MODULESEXISTING MODULES 5"REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951ATTACHMENT DETAILUNIRAC STANDARD RAIL (TYP.)GROUNDING MID/END CLAMP5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMINGATTACHMENT DETAIL (ENLARGED VIEW)SCALE: 1"=2"2S-02ATTACHMENT DETAILS-02SCALE: 1"=1'-0"1(E) ROOF SHEATHINGASPHALT SHINGLE ROOFCHANNEL NUTSOLAR MODULE(2"X4") TRUSS SPANNER ORBLOCKING FOR MISSED TRUSSATTACHMENT (IF REQUIRED)UNIRAC L FOOTUNIRAC L FOOT(2"X4") TRUSS SPANNER ORBLOCKING FOR MISSED TRUSSATTACHMENT (IF REQUIRED)SOLAR MODULESEE (2/S-02.1) FORENLARGED VIEW(E) 2"X4" TRUSSES @ 24" O.C.(E) 2"X4" TRUSSES @ 24" O.C.h2FLASH KIT PRO FLASHINGFOR HIP ROOFFLASHKIT PRO FLASHING 1'-0"1'-0"REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951ATTACHMENT DETAIL2ATTACHMENT DETAIL (ENLARGED VIEW)S-02.1SCALE: 3" = 1'-0"ATTACHMENT DETAILS-02.1SCALE: 1'' = 1'-0''1SEE (2/S-02.1) FORENLARGED VIEWSOLAR MODULEFLAT ROOF5/16"DIA. X 3"MIN. EMBEDMENT LAG SCREW ATEACH ATTACHMENT POINT INTO EXISTING FRAMINGE CURB PITCH PANSATTACHMENT ALIGNTWO FASTENERS WITHTRUSS UNDERNEATHQMLSH: QBASE LOWSLOPE MOUNTL-FOOTFLAT ROOF GROUNDING & END/MID CLAMP(E) 2"X4" TRUSSES @ 24" O.C.(E) 2"X4" TRUSSES @ 24" O.C.UNIRAC STANDARD RAIL4"X4" TRUSS SPANNER FORMISSED TRUSS SPANNER(IF REQUIRED)MAINTAIN 3/4" DISTANCE FROMTHE EDGE PER NDS 2018h₂FOR FLAT ROOF REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.2CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951STRUCTURECALCULATION FOR HIP ROOF : REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.3CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951STRUCTURECALCULATION FOR FLAT ROOF: REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951 Q CABLES1ELECTRICAL LINE DIAGRAME-01SCALE: NTSELECTRICALLINE DIAGRAML2L1NL2L1GN20A/2PGG10A(N) SOLADECK600V, NEMA 3RUL LISTEDGGGGGGGGGGPV MODULES(N) SOLAR ARRAY (5.325 kW-DC STC)(15) LG NEONR: LG355N1C-N5 (355W) MODULES(01) BRANCH OF 08 MODULES &(01) BRANCH OF 07 MODULESENPHASE: IQ7PLUS-72-2-USMICROINVERTERSGGL2L1L2L1(N) JUNCTION BOX600V, NEMA 3RUL LISTED(3) #6 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, PVC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUNL2L1L2L1NGL2L1L2L1L1L2NL2L1L2L1BI-DIRECTIONALUTILITY METER1-PHASE, 240VTO UTILITY GRIDL1L2NL1L2N(E) MAIN BREAKER200A/2P, 240V(E) MAIN DISTRIBUTIONPANEL, 200A RATED, 240VEXISTING GROUNDINGELECTRODE SYSTEMGGGGGGGGGGL2L1L2L1L2L120A/2PLINE TAP USING INSULATIONPIERCING PER NEC 705.12(A)NGL2L1NGL2L1(N) AC DISCONNECT:240V, 60AMP RATED,NEMA 3R, UL LISTED,LOCKABLE & FUSIBLE,WITH 60A FUSES(3) #6 AWG THWN-2IN 1" IMC, RMC, FMC, PVC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUNNOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BY THEFLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULEMANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURERAND MODEL NUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH NEC 312.8 IF PANELGUTTER SPACE IS INADEQUATE.3. IF THE FUSED AC DISCONNECT WIRE RUN EXCEEDS 10 FT FROMTHE POINT OF INTERCONNECTION, CABLE LIMITERS ORCURRENT-LIMITED CIRCUIT BREAKERS MUST BE INSTALLED FOREACH UNGROUNDED CONDUCTOR PER NEC 705.31.GGGGGGGGGGGGGGGGGL2L1L2L1L2L1L2L1L2L120A/2PL2L120A/2P(2) #10 AWG THWN-2 – RED(2) #10 AWG THWN-2 – BLACKEGC #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(E) MAIN DISTRIBUTIONPANEL 200A RATED, 240V(E) SOLAR ARRAY(27) LG NEON2: LG335NIC-V5 (335W) MODULES(01) BRANCH OF 14 MODULES &(01) BRANCH OF 13 MODULES(2) 10/2 ROMEX RUN IN ATTICOR(2) #10 AWG THWN-2-RED(2) #10 AWG THWN-2-BLACKEGC #6 AWG THWN-2 GNDIN 1" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUNGGGGGGGEXISTING PV MODULES (E) 125A ENPHASE IQ COMBINER 3(X-IQ-AM1-240-3) [WITH UPTO (4)2-POLE BREAKERS AND ENVOYCOMMUNICATION GATEWAY]I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLAR ENERGYCENTER CERTIFICATIONEXISTING WIRINGEXISTINGWIRING REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951 ELECTRICAL CALCULATIONELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELEDFOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TOTHE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES ANDSTANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARENOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FORUSE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).17.THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PVCONDUCTORS IN COMPLIANCE WITH NEC 690.12.18.LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWNON SHEET E-03.WIRING CALCULATIONS REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951SYSTEM LABELINGRAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECT(PER CODE: NEC 690.56(C)(3))WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]WARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!TURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSAC DISCONNECT5.33 KW SOLARDISCONNECT LOCATEDPHOTOVOLTAICSYSTEM MICROINVERTERSLOCATED UNDER EACHPV MODULE INROOF TOP ARRAYAC COMBINER BOXLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)LABEL LOCATION:INVERTER(PER CODE: NEC 690.52)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)DATA PER PANELLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 45.15 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSSOLAR CONNECTIONLINE SIDE TAPLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(A)) REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-04CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-05CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-06CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-07CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERWATTS RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-08CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC6602 BAYARD RD, FORT PIERCE, FL 34951DATA SHEET