HomeMy WebLinkAboutAPPROVED, ENERGY CALCS & MANUAL J - 172 CALLE DE LAGOSFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10, Wall Type41432.0 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int [nsul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 3
d. NIA
R= ft2
I I. Ceiling Types (1783.0 sgft.)
Insulation Area
5. [s this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30,00 ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(151.4 sgft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 195
a. U-Factor: Sgl, U=1.02 111.36 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40,00 ft2
13. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.285
a. Electric Heat Pump
34.8 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) WA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 40 gallons
9. Floor Types (1753.0 sgft.) Insulation Area
EF:0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
b. NIA R= ft2
None
c. NIA R= ft2
16. Credits
None
Total Proposed Modified Loads: 49.38
Glass/Floor Area: 0.086
PASS
Total Baseline Loads: 50.69
I�'►�7w7
1 hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
p
Code.
calculation indicates compliance
with the Florida Energy Code.
rfgakw,.'p=r 4
PREPARED BY:
Before construction is completed
w La
DATE: 1-12-2 121
this building will be inspected for
compliance with Section 553.908
1 hereby certify that this building, as designed, is i mpliance
Florida Statutes.
with the Florida Energy Cod . ^-'�ODt,i�
OWNER/ G N
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block(Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Detached
FL,
New/E)isting: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M. BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 ft 0
224 ft-
____
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC t ft 0
63 W
__
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft'
__
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 f-
__
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft'
0 1
0
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INF'U I SUMMAKY L NLUKLIJ I KLIJUKI
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft'
—
0 1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft'
_
0 1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft=
_
0 1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft'
----
0 1
0
10SIab-On-Grade Edge Insulatio
HALL t ft
0
25 ft'
0 1
0
11Slab-On-Grade Edge Insulatio
FOYER 9 It
0
92 ft'
—
0 1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft'
0 1
0
ROOF
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1847 ft'
0 ft'
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft'
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area -
Framing Free
Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft-
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft'
0.1
Wood
_
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft'
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 W
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft'
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft'
0.1
Wood
_
9 Under Attic (Vented)
BATH
30
Blown
50 f[2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 if
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 fP
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 fi=
0.11
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar Below
_ 1
NE=>SW Exterior Concrete Block- Int InsWASTER BE 4.1 16
0 8
0
128.0 ft-
0 0
0.3
0
2
SW=>NE Exterior Concrete Block - Int InsWASTER BE 4.1
7
0 8
0
56.0 it-
0 0
0.3
0
3
NW=>SE Exterior Concrete Block - Int InsWASTER BE 4.1
14
0 8
0
112.0 ft'
0 0
0.3
0
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar Below
Space
-4 NE=>SW Exterior Concrete Block - Int InsMASTER BA
4.1 8
0
8 0
64.0 ft'
0
0
0.3
0
-5 NE=>SW Exterior Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
-6 NE=>SW Exterior Concrete Block- Int InsBIEDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0.3
0
-7 SW=>NE Exterior Concrete Block - Int InsGINING/GRE
4.1 30
0
8 0
240.0 ft'
0
0
0.3
0
-8 NW=>SE Exterior Concrete Block - Int InsiBINING/GRE
4.1 20
0
8 0
160.0 ft'
0
0
0.3
0
_ 9 SW=>NE Exterior Concrete Block- Int InsulKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.3
0
10 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0
8 0
40.0 ft'
0
0
0.3
0
_ 11 SE=>NW Exterior Concrete Block - Int Insul FOYER
4.1 8
0
8 0
64.0 ft'
0
0
0.3
0
12 SW=>NE Exterior Concrete Block- Int Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13 NE=>SW Exterior Concrete Block- Int InsBIEDROOM 3
4.1 13
0
8 0
104.0 ft-
0
0
0.3
0
_ 14 SW=>NE Exterior Concrete Block - Int InsIiIEDROOM 3
4.1 1
0
8 0
8.0 ft'
0
0
0.3
0
15 N=>S Garage Frame - Wood BEDROOM 3
11 26
8
208.0 ft'
0.23
0.3
0
DOORS
V # Omt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>NW Insulated FOYER
None
.39
3
3
6 8
21.7 ft'
WINDOWS
Orientation shown is the entered orientation => chanced to Worst Case.
Wall
Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>SE 3 Metal Low-E Single Yes
1.02 0.29
Y
32.4 ft'
1 It 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>SW 5 Metal Low-E Single Yes
1.02 0.29
Y
6.9 ft=
1 ft 0 in
1 ft 4 in
None
None
_ 3 NE=>SW 6 Metal Low-E Single Yes
1.02 0.29
Y
16.2 ft2
1 It 0 in
1 ft 4 in
None
None
4 SW=>NE 7 Metal Low-E Single Yes
1.02 0.29
Y
39.8 ft2
1 It 0 in
1 ft 4 in
None
None
5 NWaSE 8 Metal Low-E Single Yes
1.11 0.27
Y
40.0 ft'
8 It 0 in
1 ft 4 in
None
None
6 NE=>SW 13 Metal Low-E Single Yes
1.02 0.29
Y
16.2 ft'
1 ft 0 in
1 It 4 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12
120.37
.0902
5
1/12/2021 1:15 PM EnergyGauge@) USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6