EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
'26 GA.SV-CRJtM>?PANEL REV1EWE CO® on
S E COMPLIANCE
FLORIDA BUILDING CODE 7TH EDITION'
F' RI"DA PRODUCT APPROVAL �
O ®cc
FL.14b45.3-R4
ROOFING
'METAL ROOFING
File Copy
Prepared.for:
Metal Sales Manufacturing Corporation
545.South Yl Street,Suite 200
Louisville;ICY 40202
Telephone: (502)855.4300
Fax: (502)855.4200
Prepared By:
Bala Sockalingam,Ph.D.,P.E.
Florida Professional Engineer#62240
1.216 N Lansing Ave.,Suite C
Tulsa,OTC 74106
"telephone: (9U)492-5992
FAX: (866)366.1543
This.report consists of
Evaluation Report(3 Pages including cover)
Installation Details(1 Page)
Load Span Table(1 Page)
o'�v�,• �G�PN��'•�9�.y�',v
b NQ 62240 •, � 'w
:tre
Report No. C2397-3 g AT E
Date: 10.7.2020 t 0 S\9�•�`,�v
1C3 .-1 . 20' 0
i�
FL 14645.3-R4
C2397-3
10.7.2020
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with(5) 1/2"high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalutne.coated steel (ASTM A792) or painted steel (ASTM A755).
Corrosion resistant as per FBC 2020 Section 1507.4.3.
Deck Description: Min. 19/32" plywood or vain. %" thick wood plant: (min SG of 0.42)
for new and existing constructions. Designed by others and installed
as per FBC 2020.
Deck Attachment: Sd x 2.5" long rung shank nails or#8 x 2" long wood screws at 6" o,.c.
(Minimum) in the field and at 4" o.c, at edges. Designed as per F13C 2020. ;
New Underlayment: Minimum underlaymeztt as per FBC 2020 Section 1507A.S.1.
Required for new construction and optional for reroofing cortstructlon.
Existing Underlayinent: One layer of asphalt shingles over one layer of#30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2_
Requires applied lap sealant for roof slopes less that) 3:12.
Design Uplift Pressure: 41.6 psf at fastener spacing of 36" o_c.
(Factor of Safety=2) 74.8 psf at fastener spacing of 16" ox,
196.75 psf at fastener spacing of 8" o_c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8". Fasteners are corrosion resistant as per FBC 2020 Section
1.507.4.4.
At panel ends 6" o.c. across panel width
At intermediate 12" o.e. across panel width
Test Standards: hoof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance ivith FBC
2020 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress
FL 14645.3-R4
C2397-3
10.7:2020
Page 3 of 3
design. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a F orida Professional
Engineer or based on Metal Sales load span tabl�. This evaluation
report is not applicable is High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2020 Section 1505 and current approved roofing materials
directory or. A.STM E1.08/UL790 report from an accredited laboratory
for fire ratings of this product.
Supporting Documents. TA,S 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T181-05, Reporting Date 7/21/05 (Tests 41 &2)
Project No. T240-09, Reporting Date 9/22/09
Architectural Testing, Inc.—West Palm.Beach,FL
(Formerly Hurricane Test Laboratory,LLQ
Project No. 0103-0712-09, Reporting Date 9/l/09
i
fam:
1]/t,70
SEE DETAIL 4 NEW UNDERAYMENT FASTENER AT PANEL FLAT F 5V-CRIMP
EXISTING SHINGLES SEE DETAIL 2 r_ (REQWRm ONLY FOR REQUIRED FOR PANEL r
(OP110HAL / v (PANE_ OVFRLAP) NEW COhSTRUCTEON)� ENDS ONLY.
R II G V z
EXISTING UNDFRLAYIIENT PANEL f&M-rm IR PER ALLOWABLE
(OPTIONAL} MINIMUM ATTACHMENT_ PFiES9JRE TABLE m
8d x 2.5' LONG RING SHANK NAIL
OR g8 x 2' LONG WOOD SCREWS r
SPACED 0 6" O.C. IN THE FIELD Z
MIN. 2X_ WOOD RAFTER/JOIST,,'-/ 4' D.C. AT PLYWOOD EDGES
TRUSS AT MAX. 24" -D.C.
TYPICAL PANEL INSTALLATION X—SECTION u N
0 hjN
vi o
09-16 OR f10-1+ WOODSCREWS
NEW UPIDERLAYiAENT Y7SH SELF SEALING WASHER AT z nwv-'i
V18:XIMLRI SPACING OF 36"O.C.
(REQUIRED ONLY FOR
NEW CONSTRUCTION) 11111 Iryn �
5V-CRIMP o0
BASTING SHINGLES MIN 26 GA.
(OPTIONAL)
Ktj
_Ld
J a i
L o
a c f, 7
EASTING UNMIWEW PLYWOOD c-
(OPTIONAL) 19/32"THICK (MIN,) GENERAL NOTES
DETAIL 1 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE-
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 G4. (t = 0.01691. EFFECTTVE CMRING
-16 DR N16-14 WOODSCREWS
4110iH OF PANEL - 24'. 12Q =fig
3. THE ROOF PANELS SHALL BE INSTALLED DYER SHEATHING do STRUCTURE AS _ F
NEW UNOERLAYMENT WITH SELF SEALING WASHER AT SPECIFIED ON THIS DRAW,TNG. � m
UAKIWUM SPACING OF 36'O.C. C REQUIRE]] DESIGN WIND LOADS SHALL 2E OET'mwNED FOR EACH PROJECT. THIS
(REQUIRED ONLY FOR
NEW CONSTRUCTION) PANEL SY5TEW MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND IAADS �m E
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5V-CRIMP S. All FASTENERS ?GUST BE: IN ACCORDANCE WITH THIS DRAWING & IMF Fl ORICA
EXISTING SHINGLES MIN 26 GA. BUILDING CODE. IF A DIFFERENCE COCURS BETWEEN THE MINIMU?A
(OPTIONAL) REQUIREMENTS OF THIS DRAIYING & THE CODE, THE CODE SHALL CONTROL
---- S. R6FTERS/J0ISTSJTRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIDIU€Y OF 4THER5.
7. REQUIRES APPLIED LAP SEALANT FOR ROOF SLOPE < 3:12.
- - -
EXISTING UNOERLAYMEN FLYW000 "`"
(OPTIONAL) 19/32' THICK (MIN.) `-'97-3
D ETA1 L 2 N6
METAL SALES MANUFACTURING CORPORATION
5V Chimp Uplift Loads
(Min.26 ga.)
Description. Fastener Spacing Allowable Uplift
along Panel Length Load
apn ( sf)
Coverage width: 24" 8 196.8
10 166.3
12 135.8
Panel Fasteners 14 105.3
#9-16 or#10-1.4 hex head 16 74.8
wood screws with sealed 18 715
washer 20 68.2 i
22 64.8
24 _ 61.5
26 58.2
28 54.9
30 5.1.6
32 i48.2
34 44.9
36 41.6
Notes:
1_ The bold numbers indicate design loads calculated frotn test data with safety factor of 2.
2. PaOls must be installed as pet Evaluation Report FL 14645.3 and Metal Sales curreht installation procedure.
3. Tbree or more spans condition.
I
r C)c K A k liv ee""
No
62240
�1. w
STATE OF
B v
1216 N Lansing Ave.,Suite C Bala Sockalhipm,Ph-D.,RE
Tulsa,Ok 74106
918 492 5992
i