HomeMy WebLinkAboutProduct Approval (2) ti , EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION '26 GA.SV-CRJtM>?PANEL REV1EWE CO® on S E COMPLIANCE FLORIDA BUILDING CODE 7TH EDITION' F' RI"DA PRODUCT APPROVAL � O ®cc FL.14b45.3-R4 ROOFING 'METAL ROOFING File Copy Prepared.for: Metal Sales Manufacturing Corporation 545.South Yl Street,Suite 200 Louisville;ICY 40202 Telephone: (502)855.4300 Fax: (502)855.4200 Prepared By: Bala Sockalingam,Ph.D.,P.E. Florida Professional Engineer#62240 1.216 N Lansing Ave.,Suite C Tulsa,OTC 74106 "telephone: (9U)492-5992 FAX: (866)366.1543 This.report consists of Evaluation Report(3 Pages including cover) Installation Details(1 Page) Load Span Table(1 Page) o'�v�,• �G�PN��'•�9�.y�',v b NQ 62240 •, � 'w :tre Report No. C2397-3 g AT E Date: 10.7.2020 t 0 S\9�•�`,�v 1C3 .-1 . 20' 0 i� FL 14645.3-R4 C2397-3 10.7.2020 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with(5) 1/2"high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalutne.coated steel (ASTM A792) or painted steel (ASTM A755). Corrosion resistant as per FBC 2020 Section 1507.4.3. Deck Description: Min. 19/32" plywood or vain. %" thick wood plant: (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2020. Deck Attachment: Sd x 2.5" long rung shank nails or#8 x 2" long wood screws at 6" o,.c. (Minimum) in the field and at 4" o.c, at edges. Designed as per F13C 2020. ; New Underlayment: Minimum underlaymeztt as per FBC 2020 Section 1507A.S.1. Required for new construction and optional for reroofing cortstructlon. Existing Underlayinent: One layer of asphalt shingles over one layer of#30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2_ Requires applied lap sealant for roof slopes less that) 3:12. Design Uplift Pressure: 41.6 psf at fastener spacing of 36" o_c. (Factor of Safety=2) 74.8 psf at fastener spacing of 16" ox, 196.75 psf at fastener spacing of 8" o_c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". Fasteners are corrosion resistant as per FBC 2020 Section 1.507.4.4. At panel ends 6" o.c. across panel width At intermediate 12" o.e. across panel width Test Standards: hoof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance ivith FBC 2020 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress FL 14645.3-R4 C2397-3 10.7:2020 Page 3 of 3 design. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a F orida Professional Engineer or based on Metal Sales load span tabl�. This evaluation report is not applicable is High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2020 Section 1505 and current approved roofing materials directory or. A.STM E1.08/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents. TA,S 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests 41 &2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc.—West Palm.Beach,FL (Formerly Hurricane Test Laboratory,LLQ Project No. 0103-0712-09, Reporting Date 9/l/09 i fam: 1]/t,70 SEE DETAIL 4 NEW UNDERAYMENT FASTENER AT PANEL FLAT F 5V-CRIMP EXISTING SHINGLES SEE DETAIL 2 r_ (REQWRm ONLY FOR REQUIRED FOR PANEL r (OP110HAL / v (PANE_ OVFRLAP) NEW COhSTRUCTEON)� ENDS ONLY. R II G V z EXISTING UNDFRLAYIIENT PANEL f&M-rm IR PER ALLOWABLE (OPTIONAL} MINIMUM ATTACHMENT_ PFiES9JRE TABLE m 8d x 2.5' LONG RING SHANK NAIL OR g8 x 2' LONG WOOD SCREWS r SPACED 0 6" O.C. IN THE FIELD Z MIN. 2X_ WOOD RAFTER/JOIST,,'-/ 4' D.C. AT PLYWOOD EDGES TRUSS AT MAX. 24" -D.C. TYPICAL PANEL INSTALLATION X—SECTION u N 0 hjN vi o 09-16 OR f10-1+ WOODSCREWS NEW UPIDERLAYiAENT Y7SH SELF SEALING WASHER AT z nwv-'i V18:XIMLRI SPACING OF 36"O.C. (REQUIRED ONLY FOR NEW CONSTRUCTION) 11111 Iryn � 5V-CRIMP o0 BASTING SHINGLES MIN 26 GA. (OPTIONAL) Ktj _Ld J a i L o a c f, 7 EASTING UNMIWEW PLYWOOD c- (OPTIONAL) 19/32"THICK (MIN,) GENERAL NOTES DETAIL 1 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE- FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 G4. (t = 0.01691. EFFECTTVE CMRING -16 DR N16-14 WOODSCREWS 4110iH OF PANEL - 24'. 12Q =fig 3. THE ROOF PANELS SHALL BE INSTALLED DYER SHEATHING do STRUCTURE AS _ F NEW UNOERLAYMENT WITH SELF SEALING WASHER AT SPECIFIED ON THIS DRAW,TNG. � m UAKIWUM SPACING OF 36'O.C. C REQUIRE]] DESIGN WIND LOADS SHALL 2E OET'mwNED FOR EACH PROJECT. THIS (REQUIRED ONLY FOR NEW CONSTRUCTION) PANEL SY5TEW MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND IAADS �m E ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5V-CRIMP S. All FASTENERS ?GUST BE: IN ACCORDANCE WITH THIS DRAWING & IMF Fl ORICA EXISTING SHINGLES MIN 26 GA. BUILDING CODE. IF A DIFFERENCE COCURS BETWEEN THE MINIMU?A (OPTIONAL) REQUIREMENTS OF THIS DRAIYING & THE CODE, THE CODE SHALL CONTROL ---- S. R6FTERS/J0ISTSJTRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIDIU€Y OF 4THER5. 7. REQUIRES APPLIED LAP SEALANT FOR ROOF SLOPE < 3:12. - - - EXISTING UNOERLAYMEN FLYW000 "`" (OPTIONAL) 19/32' THICK (MIN.) `-'97-3 D ETA1 L 2 N6 METAL SALES MANUFACTURING CORPORATION 5V Chimp Uplift Loads (Min.26 ga.) Description. Fastener Spacing Allowable Uplift along Panel Length Load apn ( sf) Coverage width: 24" 8 196.8 10 166.3 12 135.8 Panel Fasteners 14 105.3 #9-16 or#10-1.4 hex head 16 74.8 wood screws with sealed 18 715 washer 20 68.2 i 22 64.8 24 _ 61.5 26 58.2 28 54.9 30 5.1.6 32 i48.2 34 44.9 36 41.6 Notes: 1_ The bold numbers indicate design loads calculated frotn test data with safety factor of 2. 2. PaOls must be installed as pet Evaluation Report FL 14645.3 and Metal Sales curreht installation procedure. 3. Tbree or more spans condition. I r C)c K A k liv ee"" No 62240 �1. w STATE OF B v 1216 N Lansing Ave.,Suite C Bala Sockalhipm,Ph-D.,RE Tulsa,Ok 74106 918 492 5992 i