Loading...
HomeMy WebLinkAboutAPPROVED Gibson_Kolakotanya_ENG WCONSULTING-A Wyssling Consulting 76 North Meadowbrook Drive Alpine, UT 84004 Scott E. Wyssling, PE, PP, CME office (201) 874-3483 swyssling@wysslingconsulting.com July 16, 2021 Digitally signed by Scott Wyssling PE DN:C=US,S=Utah,L=Alpine,O=Scott Wyssling PE,CN=Scott Wyssling PE, Scott Wyssling PEE=swys:Ia,the author of this Reason: am the author of this document Location:your signing location here Date:2021.07.16 05:26:56-04'00' Jacob Humpherys, COO Foxit PhantomPDF Version:10.1.3 Meraki Solutions 30700 Wekiva River Road Sorrento, FL 32776 Re: Engineering Services Gibson Residence 3701 Avenue T, Fort Pierce, FL 10.560 kW System Dear Mr. Humphreys: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Meraki Solutions representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by Meraki Solutions and will be utilized for approval and construction of the proposed system. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of truss system with all chords constructed of 2 x 4 dimensional lumber at 24" on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce Pine Fir #2 or better with standard construction components. The existing roofing material consists of composite asphalt shingles. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used • 160 MPH wind loading based on ASCE 7-16 Exposure Category "C" at a slope of 20 degrees • 7 PSF = Dead Load roofing/framing Live Load = 20 PSF/0 PSF(where panels are installed) • 3 PSF = Dead Load solar panels/mounting hardware Total Dead Load=10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the (FBC 2020, Th Edition). Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ironridge Installation Manuaf', which can be found on the Ironridge website (http://ironridge.coml). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Spruce Pine Fir #2 assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 '/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 W with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 48" o/c. 4. Panel supports connections shall be staggered to distribute load to adjacent trusses. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the FBC 2020, 71h Edition, current industry and standards, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V t`y your + Scott E.Wyssli , PE Florida License No. N ;.. ri CAN F'+ THIS PLAN HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SCOTT WYSSLING,PE USING A DIGITAL �. SIGNATURE AND DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND YAT � SEALED AND THE SIGNATURE MUST BE VERIFIED { ON ANY ELECTRONIC COPIES opovA` , rS ON+ JJII WCONSULTING AERIAL VIEW: STREET VIEW: MEFRAKI ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 _ 21 N New Warrington Rd Pensacola, FL 32507 License # CVC57044 _� ■■■■■■■■ ■� g �■ ■■■■■■■■ ■■ �� eG • �� ■ • SITE INFORMATION Kolakotanya Gibson _ NiN�h; - 3701 Avenue T Fort Pierce, FL 34947 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 10.56 kW DC Lat, 27.4682490747608 _. Long,-80.3623814588954 (32) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE10000H-US(240V) INVERTER(S) ' `' Florida Power&Light GENERAL NOTES PHOTOVOLTAIC (PV) SYSTEM SPECIFICATIONS : EW �;cHs •, r SHEET INDEX: 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE EQUIPMENT: _ Ngi PV01 COVER PAGE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. AC SYSTEM SIZE: 10 kW AC •�toF �� PV02 SITE PLAN DC SYSTEM SIZE: 10.56 kW DC •'''OR1•° 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL ��''/i�IV/YONAi.EN°��`��\ PV03 ROOF PLAN (32) TSM-DD06M.05(II) 330 PV MODULES '��II/111ioi � EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. THIS PLAN HAS BEEN ELECTRONICALLY SIGNED AND SEAL PV04 ROOF ATTACHMENTS (1) SolarEdge SE10000H-US (240V) INVERTER(S) PR TED oPIESOFTHISDOCUMENTAREINOTTCONSDOEI !" PV05 MOUNTING DETAIL 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM RACKING: Iron Ridge - 48" O.C. SIGNED&SEALED AND THE SIGNATURE MUST BEVERIF1EO N PV06 LINE DIAGRAM ANY ELECTRONIC COPIES. PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 PV07 LABELS 4. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER APPLICABLE GOVERNING CODES SITE SPECIFICATIONS PV08 PLACARD UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 2020fec OCCUPANCY: R-3 PV09 SITE PHOTOS 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 2020 FBC-Residential,7th edition ADOPTS WITH ZONING: RESIDENTIAL AMENDMENTS: International Residential Code 2018(IRC 2018) DRAWN BY: SoloCAD 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.311 2020ffc 7. ALL SIG NAG E TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. 2020 FBC-Building,7th edition ADOPTS WITH AMENDMENTS: DATE: International Building Code 2018(IBC 2018) July 14, 2021 COVER PAGE - PV01 N 3701 Avenue T MERAKI ZERO DOWN SOLAR CONTRACTOR INFORMATION: FRONT OF HOME Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License #CVC57044 SITE INFORMATION Kolakotanya Gibson 3701 Avenue T Fort Pierce, FL 34947 1141-711 AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 10.56 kW DC Lat, 27.4682490747608 JB 93'-1 Long,-80.3623814588954 B (32) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE1000OH-US(240V) INV INVERTER(S) Ac I Florida Power&Light MSP M MP2 MP1 PITCH: 20° I ENGINEER STAMP AZIMUTH: 1800 (IF APPLICABLE) PITCH: 200 Wye. f� AZIMUTH: 180° �� E WVS`4�'/��� 4 .y CfcIVB�., y • NOt _ N J1111I IIINO\`````� THIS PLAN HAS BEEN ELECTRONICALLY 51GNED AND SEALED 00, 146' 1 011 BY SCOTT WYSSU NG,PE USING A DIGITAL SIGNATURE&DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED&SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. EQUIPMENT LEGEND: DRAWN BY: SOIOCAD VISIBLE, LOCKABLE, UTILITY METER Ae AC VISIBLE, LOCKABLE, LABELED Nv INVERTER suB SUB PANEL ® FIRE ACCESS PATHWAY(3'TYP) BATT BATTERY(IES) LABELED AC DISCONNECT DATE: LOCATED WITHIN 10' July 14, 2021 METER SOCKET i OF UTILITY METER MSP MAIN SERVICE PANEL Pv (FOR UTILITY T METER) El COMBINER BOX r� LOAD CENTER i PROPERTY LINE SITE PLAN - PV02 N FRONT OF HOME MERAKI ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License #CVC57044 SITE INFORMATION Kolakotanya Gibson 3701 Avenue T Fort Pierce, FL 34947 T TYP AC SYSTEM SIZE: 10 kW AC DC SYSTEM SIZE: 10.56 kW DC JB Lat, 27.4682490747608 MP1 Long,-80.3623814588954 PITCH: 20° JB (32) TSM-DD06M.05(II) 330 PV MODULES AZIMUTH: 1800 (1) SolarEdge SE10000H-US(240V) IE O INVERTER(S) Florida Power&Light INV ENGINEER STAMP (IF APPLICABLE) AC \\\111E I I�V M P2 fi, 4 •v�CfcIVB�.• S MSP PITCH: 20° ` t AZIMUTH: 180° M-11 LILILILI I •I -I T TYP THIS PLAN HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SCOTT WYSS LING,PE USING A DIGITAL SIGNATURE&DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED&SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. EQUIPMENT LEGEND: DRAWN BY: SoloCAD VISIBLE, LOCKABLE, LABELED VISIBLE, LOCKABLE, Ac UTILITY METER AC DISCONNECT rvv INVERTER SU6 SUB PANEL ® FIRE ACCESS PATHWAY (3'TYP) LABELED AC DISCONNECT DATE: LOCATED WITHIN 10' July 14, 2021 MSP MAIN SERVICE PANEL METER SOCKET c❑ COMBINER BOX Le LOAD CENTER BATT BATTERY(IES) OF UTILITY METER Pv (FOR UTILITY PV METER) ROOF PLAN - PV03 N MERAKI ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 O License #CVC57044 SITE INFORMATION J 0* 4'-0" Kolakotanya Gibson 3701 Avenue T Fort Pierce, FL 34947 I NV / AC SYSTEM SIZE: 10 kW AC �/ DC SYSTEM SIZE: 10.56 kW DC Lat, 27.4682490747608 Long,-80.3623814588954 AC 9 (32) TSM-DD06M.05(II) 330 PV MODULES (1) SolarEdge SE1000OH-US(240V) INVERTER(S) Florida Power&Light MSP ENGINEER STAMP (IF APPLICABLE) ����uluuuupn/f/ M �� E wVss�/G�i 4 .y CfcIVB�., y • No — EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: �/i��s/oru1111�N°����`�� RAIL MANUFACTURER IronRid e ROOF TYPE asphalt shingle THIS PLAN HAS BEEN ELECTRONICALLY 5IGNLD AND SEALED g p g PV MODULE COUNT: 32 BY SCOTT WYSSLING,PE USING A DIGITAL SIGNATURE&DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED RAIL PART NUMBER XR-100 ROOF FRAMING manufactured_truss ARRAY AREA: MODULE COUNT * 18.06ft2= 577.92 SIGNED&SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ATTACHMENTS FlashVue RAFTER/TOP CHORD SIZE 2x4 ROOF AREA: 2600 ftz ATTACHMENT CITY 60 RAFTER/TOP CHORD SPACING 24" PERCENT OF ROOF COVERED: 22% DRAWN BY: SoloCAD SPLICE CITY 8 ATTACHMENT SPACING 48 ARRAY WEIGHT: MODULE COUNT * 501bs = 1600 DATE: MIDCLAMP CITY 52 July 14, 2021 DISTRIBUTED LOAD: ARRAY LBS/ATTACHMENTS = 26.67 ENDCLAMP CITY 24 POINT LOAD: (Ibs/ft2) (ARRAY) WEIGHT/AREA= 2.77 Ibs/ft2 ROOF ATTACHMENTS - PV04 MID CLAMP PV MODULE END CLAMP 1 2 PV MODULE FRAME �RAIL RAIL t t( RAIL MERA�KI ZERO DOWN SOLAR 1 -8 MAX SPAN MAX. CONTRACTOR INFORMATION: 1 END CLAMP DETAILS 2 MID CLAMP DETAILS FRONT VI EW (E) RAFTER/TOP CHORDS Meraki Installers 484-663-3792 21 N New Warrington Rd PV MODULE Pensacola, FL 32507 License #CVC57044 RAIL RAIL SITE INFORMATION ATTACHMENT Kolakotanya Gibson (E)COMP SHINGLE ROOF(1 LAYER) 1 0" MIN _ 3701 Avenue T Lj 4" 11-411 3 Fort Pierce, FL 34947 7 MAX AC SYSTEM SIZE: 10 kW AC 1 Q" MIN - DC SYSTEM SIZE: 10.56 kW DC 2'-8" MIN - 1`-411 Lat, 27.4682490747608 ATTACHMENT T-10" MAX MAX Long,-80.3623814588954 (32) TSM-DD06M.05(II) 330 PV MODULES 2.5"MIN. EMBED. FLASHING(SEE DATASHEET FOR DETAILS) (E) RAFTER/TOP CHORD (1) SolarEdge SE10000H-US(240V) 2'-8" MIN - INVERTER(S) 3'-10" MAX Florida Power&Light 5/16"STAINLESS STEEL LAG BOLT WITH 2-1/2"MIN. EMBEDMENT (PER MANUFACTURER) (E) RAFTER/TOP CHORD ENGINEER STAMP (IF APPLICABLE) DETAIL, MOUNTING AND FLASHING WB V 3 SIDE VIEW 4 .v OHlV •• S • EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: RAIL MANUFACTURER IronRid e ROOF TYPE asphalt shingle THIS PLAN HAS BEEN ELECTRONICALLY5IGNLD AND SEALED g p g PV MODULE COUNT: 32 BY SCOTT WYSSLI NG,PE USI NG A DIGITAL SIGNATURE&DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED RAIL PART NUMBER XR-100 ROOF FRAMING manufactured—truss ARRAY AREA: MODULE COUNT * 18.06ft2= 577.92 SIGNEDC SCALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELE[TRONIC COPIES. ATTACHMENTS FlashVue RAFTER/TOP CHORD SIZE 2x4 ROOF AREA: 2600 ftz ATTACHMENT QTY 60 RAFTER/TOP CHORD SPACING 24" PERCENT OF ROOF COVERED: 22% DRAWN BY: SOIOCAD SPLICE QTY 8 ATTACHMENT SPACING 48 ARRAY WEIGHT: MODULE COUNT * 501bs = 1600 DATE: MIDCLAMP QTY 52 July 14, 2021 DISTRIBUTED LOAD: ARRAY LBS/ATTACHMENTS = 26.67 ENDCLAMP QTY 24 POINT LOAD: (IbS/ft2) (ARRAY) WEIGHT/AREA= 2.77 IbS/ft2 MOUNTING DETAIL - PV05 Conduit&Conductor Schedule EQUIPMENT SCHEDULE: TAG WIRE GAUGE DESCRIPTION CITY CONDUITSIZE CONDUCTOR #OF CONDUCTORS TEMP.DERATE CONDUCTOR RATING CONDUIT FILL RATING DERATE W/DERATES TYPE: QTY: DESCRIPTION: RATING: 10AWG PV-WIRE,USE-2, (2) N/A-FREE AIR 40A N/A-FREE AIR 0.96 33.6A N/A-FREE AIR MODULES: (32) TSM-DD06M.05(II)330 330W 1 6 AWG BARE,COPPER(GROUND) (1) INVERTERS: (1) SolarEdge SE1000OH-US(240V) 10000 W 10 AWG THWN-2,or THHN,or 10/2 NM-B COPPER-(Ll,L2) (2) z 3/4"EMT 40A 1 0.96 33.6A 11.9% AC DISCONNECT(S): (1) PV AC DISCONNECT,240V,2-POLE 60A 10 AWG TH or THHN,or10/2 NM-B COPPER-(GROUND) (1) MERAKI 10 AWG THHN/THN/THWN-2,COPPER-(L1,L2) (4) DC OPTIMIZERS: (32) SolarEdgeP340 15Adc 10A THHN/THWN-2-(GROUND) (1) 3 3/4"EMT 40A 0.8 0.96 26.88A 19.8% WG 6 AWG THWN-2 COPPER-(L1,L2,NEUTRAL) (3) ZERO DOWN SOLAR 4 3/4"EMT 65A 1 0.96 62.4A 36.5% 8AWG THWN-2 COPPER-(GROUND) (1) CONTRACTOR INFORMATION: Meraki Installers SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2017,AND THOSE SET 484-663-3792 FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING- MAXIMUM NUMBER OF MODULE 21 N New Warrington Rd STRINGS. MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND Pensacola, FL 32507 MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER. License #CVC57044 STRING(1):13.2 A DC SUPPLY SIDE CONNECTION: SITE INFORMATION NEC 230.46,NEC 230.79, - 16 MODULES Ar - - SolarEdge SE10000H-US NEC 705.12(A) Kolakotanya Gibson (240V) �(E) MAIN SERVICE PANEL PV AC DISCONNECT 3701 Avenue T 60A FUSED, AIC 10kA (E) UTILITY METER UL 1741 COMPLIANT Fort Pierce, FL 34947 - INTEGRATED RAPID VISIBLE,LOCKABLE, OPEN SHUTDOWN DC DISCONNECT N AC SYSTEM SIZE: 10 kW AC 240V,2-POLE (E)200A-2P STRING(2):13.2A DC J-BOX � DC SYSTEM SIZE: 10.56 kW DC 2 Lat, 27.4682490747608 1 DC Long,-80.3623814588954 16 MODULES Ar IN)60A FUSES (E)LOADS (32) TSM-DD06M.05(II) 330 PV MODULES --- -- AC --- ■ (1) SolarEdge SE10000H US(240V) -------- - - ------ I I INVERTER(S) J-BOX J-BOX I Florida Power&Light N 1 2 3 120/240 VAC 4 4 I r TO UTILITY GRID -- --- ENGINEER STAMP (IF APPLICABLE) %UN1111ut1 .. (E) GROUNDING/�� E, yy�ss ELECTRODE ( I 4 �•v�CHIVB�.• S iNOf _ INTERCONNECTION NOTES ���''.t��sj0R41D GROUNDING&GENERAL NOTES: 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.91&[NEC 230.95] ���iiq�0N111i �,�V�� 1. PV INVERTER IS UNGROUNDED,TRANSFORMER-LESS TYPE. 2. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)]WITH SERVICE ENTRANCE THIS PLAN HAS BEEN ELECTRONICALLY5IGNLD AND SEALED BY SCOTT WYSSLING,PE USING A DIGITAL SIGNATURE&DATE. 2. DC GEC AND AC EGC TO REMAIN UNSPLICED,OR SPLICED TO EXISTING ELECTRODE CONDUCTORS IN ACCORDANCE WITH[NEC 240.21(B)] PRINTED COPIES OF THIS DO_UMENT ARE NOT CONSIDERED 51GNED&SEALED AND THE SIGNATURE MUST BE VERIFIED ON 3.ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE VISIBLE, LOCKABLE, ANV ELECTRON IC COPIES. INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. DISCONNECT NOTES LABELED AC DISCONNECT 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE LOCATED WITHIN 10' DRAWN BY: SOIOCAD 4.JUNCTION BOX QUANTITIES,AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD-JUNCTION CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED"LINE SIDE" OF UTILITY METER BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. (TYPICALLY THE UPPER TERMINALS) DATE: 5.AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE,AND July 14, 2021 AC DISCONNECTING MEANS IS LOCATED WITHIN 10'OF SERVICE DISCONNECT. BE A VISIBLE-BREAK SWITCH. 3. FUSED AC DISCONNECT TO BE USED. LINE DIAGRAM - PV06 LABEL 1 LABEL 6 WARNING FOR PV DISCONNECTING MEANS WHERE THE LINE AND WARNING: • • • ' AT DIRECT-CURRENT EXPOSED RACEWAYS,CABLE TRAYS,COVERS AND ENCLOSURES OF JUNCTION BOXES,AND OTHER WIRING METHODS; ELECTRIC SHOCK HAZARD LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN SPACED AT MAXIMUM 1OFT SECTION OR WHERE SEPARATED BY POSITION. POWER • r ENCLOSURES,WALLS,PARTITIONS,CEILINGS,OR FLOORS. TERMINALS ON THE LINE AND [NEC 690.13(B)] [NEC 690.31(G)(3&4)] LOAD SIDES MAY BE ENERGIZED MERAKI µ�.n.. IN THE OPEN POSITION ,..:-- LABEL 7 SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS ZERO DOWN SOLAR WITH RAPID SHUTDOWN LEAVING THE ARRAY: LABEL 2 SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE /P\ f/r I I A I f�'� PLACED ADJACENT TO THE BACK-FED BREAKER TURN RAPID SHUTDOWN DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED / \Y Y f�+� 1 Y N G FROM THE INVERTER IF TIE IN CONSISTS OF SWITCHTOTHE AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID CONTRACTOR INFORMATION: LOAD SIDE CONNECTION TO BUSBAR. 'OFF'POSITION TO saaxeFc Ric SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. INVERTER OUTPUT CONNECTION [NEC 705.12(B)(2)(3)(b)] SHUT DOWN PVSYSTEM P/PANELB ANDREDUCE [NEC 690.56(C)(1)(A)] Meraki Installers DO NOT RELOCATE SHOCKHAZARD 484-663-3792 a THIS OVERCU'FtRENT IN THE ARRAY 21 N New Warrington Rd DEVICE Pensacola, FL 32507 License #CVC57044 LABEL 8 ` • • • • 1 FOR PV SYSTEMS THAT ONLY SHUT DOWN L�If IlA R N I N G 1 1 1 CONDUCTORS LEAVING THE ARRAY: LABEL 3 PLACED ADJACENT TO THE BACK-FED BREAKER SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT TURN ID AWAY FROM SERVICE DISCONNECTING MEANS TO FROM THE INVERTER IF TIE IN CONSISTS OF 70THE"OFF POSITION ® WHICH THE PV SYSTEMS ARE CONNECTED AND SITE INFORMATION THIS EQUIPMENT FED BY MULTIPLE LOAD SIDE CONNECTION TO BUSBAR. TOSHUT DOWN CONDUCTORS ------ SHALL INDICATE THE LOCATION OF ALL IDENTIFIED [NEC 705.12(B)(2)(3)(c)] DUTSIDE THE CTORSWITHI ------ RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME Kolakotan a Gibson SOURCES.TOTAL RATING OF ALL CONDUCTORS WITHIN y THE ARRAY REMAIN LOCATION. 3701 Avenue T OVERCURRENT DEVICES,EXCLUDING ENERGIZED IN SUNLIGHT [NEC690.56(C)(1)(b)] MAIN SUPPLY OVERCURRENT Fort Pierce, FL 34947 DEVICE..SHALL NOT EXCEED AMPACITY OF BUSBAR. AC SYSTEM SIZE: 10 kW AC RAPID SHUTDOWN LABEL 9 DC SYSTEM SIZE: 10.56 kW DC SIGN LOCATED AT RAPID SHUT DOWN Lat, 27.4682490747608 LABEL 4 13WITCH FOR DISCONNECT SWITCH[NEC 690.56(C)(3)]. 0 WA R N I N G EQUIPMENT CONTAINING OVERCURRENT DEVICES IN rPVSYSI Long,-80.3623814588954 CIRCUITS SUPPLYING POWER TO A BUSBAR OR EM CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL (32) TSM-DD06M.05(II) 330 PV MODULES DUAL POWER SUPPLY BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES.[NEC 705.12(B)(3)] SOURCES: UTILITY GRID AND (1) SolarEdge SE1000OH-US(240V) PV SOLAR ELECTRIC SYSTEM INVERTER(S) Florida Power&Light MAIN SERVICE PANEL LABEL 5 AT POINT OF INTERCONNECTION,MARKED AT AC RATED AC OUTPUT CURRENT., 42 DISCONNECTING MEANS. LABELING DIAGRAM: ENGINEER STAMP O O • •' • 240 [NEC 690.54,NEC 690.13(B)] 1 2 EXISTING SUB PANEL PV COMBINER INVERTER(S) (IF WHERE POINT OF SUBPANEL- (IF APPLICABLE) OO INTERCONNECTION IF USED TO COMBINE IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS 0 0 O O O O O O7 OR O O O O HDC JUNCTION BOX OR COMBINER BOX LABELING NOTES: �io 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. (ONLY (ONLY ❑ O O 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD INTERCONNECTION INTERCONNECTION 19010.145,ANSI Z535. CONSISTS OF LOAD CONSISTS OF LOAD DRAWN BY: SoIoCAD 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. SIDE BREAKER) SIDE BREAKER) 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC 110.21(B)(3)] INTEGRATED DC DISCONNECT DATE: 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND,REFLECTIVE,AND *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL July 14, 2021 PERMANENTLY AFFIXED[IFC 605.11.1.1] LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. LABELS - PV07 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED MEFRAKI SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: ZERO DOWN SOLAR N FRONT OF HOME CONTRACTOR INFORMATION: Meraki Installers 484-663-3792 21 N New Warrington Rd INVERTER & RAPID Pensacola, FL 32507 SHUTDOWN DC License # CVC57044 DISCONNECT SWITCH SITE INFORMATION a Kolakotanya Gibson B 3701 Avenue T Fort Pierce, FL 34947 INV AC SYSTEM SIZE: 10 kW AC Ac DC SYSTEM SIZE: 10.56 kW DC AC DISCONNECT Lat, 27.4682490747608 Long,-80.3623814588954 MAIN DISTRIBUTION JPV ARRAY (32) TSM-DD06M.05(II) 330 PV MODULES UTILITY DISCONNECT (1) SolarEdge SE10000H-US(240V) INVERTER(S) 3701 Avenue T, Fort Pierce FL 34947 Florida Power&Light DIRECTORY ENGINEER STAMP PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE (IF APPLICABLE) SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C), [NEC 705.101) DRAWN BY: SoloCAD DATE: July 14, 2021 PLACARD - PV08 SITE PHOTOS: I 41 Icy I,. SIEMENS MERAKI A_oa ew T 11e ZERO DOWN SOLAR CONTRACTOR INFORMATION: Meraki Installers r T � q l k 484-663-3792 21 N New Warrington Rd Pensacola, FL 32507 License #CVC57044 SITE INFORMATION Kolakotanya Gibson 3701 Avenue T T FPL AC D3284 G-GJ Fort Pierce, FL 34947 ao�_sp3a_sllao AC SYSTEM SIZE: 10 kW AC fl _ _ ;, I DC SYSTEM SIZE: 10.56 kW DC Lat 27.4682490747608 Long,-80.3623814588954 (32) TSM-DD06M.05(II) 330 PV MODULES I Im (1) SolarEdge SE1000OH-US(240V) INVERTER(S) f Florida Power&Light ENGINEER STAMP (IF APPLICABLE) I IIUI t � — DRAWN BY: SoloCAD b " DATE: ir' ,•:; ("" July 14, 2021 SITE PHOTOS - PV09 Mori, Multi Solutions Residential Module MULTI-BUSBAR 120 HALF-CELL BOB MODULE DIMENSIONS OF PV MODULE(mm) THE I ELECTRICAL DATA(STC) Peak Power Watts-PN (Wp)* 330 Power Output Tolerance-Pnex(W) -5+3% Residential Module da,. 4 09 t4 Maximum Power Voltage-Vr+ac(V) 33.6 nstalling We A Maximum Power Current-INee(A) 9.76 MULTI-BUSBAR120 HALF-CELL BOB MODULE * g Open Circuit Voltage-Voc(V) 40.6 ShortCircuitCurren (A) = 10.40 cmui,omg N°I° t-Isc Module Efficiency nm(%) 19.6 12-Dram Nde STC:Irradiance 1DOOW/mz,Cell Temperature 25°C,Air Mass AM1.5. 1 Z 0 Cell Measuring tole once±3No. PRODUCTS BACKSHEET POWER COLOR RANGE ELECTRICALDATA(NMOT) String Inverter Configuratbn MONOCRYSTALLINE MODULE TSM-DD06M.05(II) Black 330W Maximum Power-PnAx(Wp) 250 Maximum Power Voltage-Vnac(V) Nor 31.7 FRAME COLOR: Black 330 ■�■ _' � Maximum Power Current-IMPP(A) 7.86 WOpen Circuit Voltage-Voc(V) 38.3 POWER OUTPUT RANGE ^-09x14 stalling Hde� Short Circuit Current-Isc(A) 8.38 High power output A ,A x NMOT:I«alliance at OOOW/m�,Ambient Temperature 20°C.Wind Speed lm/s. • Reduce BOS cost with high power bin and 1000V system voltage 'i 19■6% • New cell string layout and split]-box location reduces the energy loss s4a MECHANICALDATA caused by inter-row shading °°a'°gNek Solar Cells Monocrystalline MAXIMUM EFFICIENCY • Lower resistance of half-cut cells and increased MBB(Multi Busbar) 12-°ra'""°'° Cell Orientation 120 cells(6 x 20) reflectance ensure higher power Module Dimensions 1690 x 996 x 35 mm(66.54 x 39.21 x 1.38 inches) _ High energy generation,low LCOE Micro!aveerorOptimizerConfiguration Weight 18.0 kg(39.7lb) 5W+3% Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Heat Strengthened POSITIVE POWER TOLERANCE 6 • Excellent 3rd party validated IAM and low light performance with cell u.5 Silica°sealant e slur°nseahnt Encapsulant Material Glass EVA process and module material optimization gym'd1e gym'°a`e Backsheet Black[DD061a.05(II)] • Low Pmax temp coefficient(-0.36%)increases energy production name rra„a Frame 35 mm(1.38 inches)Anodized Aluminium Alloy Founded in 1997,Trina Solar is theworld's leading • Better anti-shading performance and lower operating temperature comprehensive solutions provider for solar energy, as zas J-Box IP68rated we believe ciose cooperation with our partners is critical to success.Trina Solar now distributes its AA se Cables Photovoltaic Technology Cable 4.Omm2(0.006inches2) PV products Lo over 60 couruies all overthe Outstanding visual appearance,easyto install Portrait:N 140mm/P 265mm(5.51/11.22inches) world.Trina is able to provide exceptional service I-VCURVES OF PV MODULE(330W) toed chcustomerin each market and supplement • Designed for superior rooftop aesthetics Landscape:N1200mm/P1200mm(47.24/47.24inches) our innovative,reliable products with the backing of Trina as a strong,bankable partner.We are •Thinner wires give an eye catching all black look - Connector MC4 committed to building strategic,mutually ,•,„ beneficial collaboration with installers,developers, • Safe and easy to transport,handle,and install distributors and other partners. F a .wwim Certified to perform in highly challenging environments TEMPERATURE RATINGS MAXIMUM RATINGS Comprehensive Products NMOT(NiM°auleoperatingTemperature) 410C(±3°q Operational Temperature -40-+85°C And System Certificates • High PID resistance through cell process and module material control Temperature Coefficient of PMAx 0.36%/°C Maximum System Voltage 1000V DC(IEC) UL61730 • Resistant to salt,acid,sand,and ammonia °"°BM" Temperature Coefficient of Voc -0.26%/°C 1000VDC(UL) IEC61215/IEC61730/UL1703/IEC61701/IEC62715 • Over 30 in-house tests(UV,TC,HF etc) P-V CURVES OFPV MODULE(33OW) ISO9001:Quality Management System Temperature Coefficient oflsc 0.04%/°C Max Series Fuse Rating 20A ISO14001:Environmental Management System • Certified to 5400 Pa positive load and 2400 Pa negative load IS014064:Greenhouse gases Emissions Verification (DO NOT connect Fuse in Combiner Box with two or more strings in parallel connection) OHSAS 18001:Occupation Health and Safety n WARRANTY fy PACKAGING CONFIGURATION Management System PERFORMANCE WARRANTY 12 year Product Workmanship Warranty Modules per box:30pieces nnc c®us lO Year Product Warranty•25 Year Power Warranty 25 year Power Warranty Modules per 40'container:780 pieces �0 taxr�v 9 _ 7.5 ■ Trina Standard (Please refer to product warranty for details) �+ Z.5% 4 ,° a, ° « ro • s 90 Power Optimizer MID For North America Power Optimizer P320 / P340 / P370 / P400 / P405 / P505 O For North America 'or ' •. moduleigher 60-cell , power (for thin film current P320 / P340 / P370 / P400 / P405 / P505 •• Modules) mINPUT Rated Input DC Power°i 320 340 370 400 405 505 W Absolute Maximum Input Voltage 48 60 80 125z) 87i2i Vdc 25 (Voc O at lowest temperature) � MP . M PPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-87 Vdc RRANTY Maximum Short Circuit Current 11 10.1 14 Adc (Isc) Maximum DC Input Current 13.75 1 12.5 17.5 Adc 1:WARV Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II �I OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) N Safety Output Voltage per 1±0.1 Vdc Power Optimizer STANDARD COMPLIANCE N EMC FCC Pal Class 3,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 Material UL94 V-0,UV Resistant ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(W x L x H) 129x153x27.5/5.1x6x1.1 129,x153x33.5/ 129x159x49.5/ 129x162x59/ mm/in 5.1x6x1.3 5.1x6.3x1.9 5.1x6.4x2.3 Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb Input Connector Single or dual MC4(3i Input Wire Length 0.16/0.52 m/ft Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 0.9/2.95 1.2/3.9 m/ft PV power optimization at the module-level Operating Temperature Range -40-+85/-40-+185 `C/°F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % Specifically designed to work with SolarEdge / Fast installation with a single bolt r)Rated power of the module at STC will not exceed the optimizer'Rated Input DC Power".Modules with up to+5%power tolerance are allowed m NEC 2017 requires max input voltage be not more than 80V inverters For other connector types please contact SolarEdge / Next generation maintenance with module- Up to 25%more energy level monitoring PV System Design Using Single Phase Single phase Three Phase 208V Three Phase 480V a SolarEdge Inverter(4)(5) HD-Wave / Superior efficient 99.5% Minimum String Length P320,P340,P370, 8 10 18 p y( ) / Meets NEC requirements for arc fault g g P400 (Power Optimizers) P405/P505 6 13(12 with SE3K) 14 protection (AFCI) and Photovoltaic Rapid / Mitigates all types of module mismatch losses, Shutdown System PVRSS (Power Optimizers) Length 25 25 50t61 y ( ) (Power Optimizers) from manufacturing tolerance to partial 5700(6000 with shading / Module-level voltage shutdown for installer Maximum Power per String SE7600-US-SE11400- 5250 6000m 127500) W US) and firefighter safety Parallel Strings of Different Lengths Yes / Flexible system design for maximum space or Orientations utilization (41 For detailed string sizing information refer to:http://w ..solaredge.com/sites/default/files/string_sizing_na.pdf (I It is not allowed to mix P405/1`505 with P320/P340/P370/P400 in one string w A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement m For SE14.4KUS/SE43.2K1JS:It is allowed to install up to 6,500W per string when 3 strings are connected to the inverter(3 strings per unit for SE43.2KU5)and when the maximum power difference between the strings Is up to 1,000W iA For SE30KUS/SE33.3KUS/SE66.6KUS/SE100KUS:It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter(3 strings per unit for SE66.6K1JS/SE100KUS) and when the maximum power difference between the strings is up to 2,000W solaredge.com solar • • Al SolarEdge Technologies Ltd.All rights reserved.SOLAREDGE,the SolarEdge logo,Date: OPTIMIZED1BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc. C E Ro H S All other trademarks mentioned herein are trademarks of their respective owners.Date:07/2019/VOl/ENG NAM.Subject to change without notice. Single Phase Inverter with HD-Wave Technology for North America Single Phase Inverter z SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US / SE1140OH-US OUTPUT with HD-Wave Technology m Rated AC Power Output 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V or North America X Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / (211-240-264) Vac AC Output Voltage Min:Nom:Max. ✓ _ ✓ _ _ ✓ Vac SE760OH-US / SE10000H-US / SE1140OH-US I..'..I (183-208-229) AC Frequency(Nominal) 59.3-60-60.501 Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V solar,-_T�r,,7- Maximum Continuous Output 16 24 48.5 A Current @208V GFDI Threshold 1 A solar=..•.^' Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 7750 1 9300 1 11800 1 15500 17650 W Maximum DC Power @208V - 5100 7750 15500 W ® Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc • 0000 Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V121 8.5 10.5 13.5 16.5 20 27 30.5 Adc n r=` Maximum Input Current @208VO - 9 - 13.5 - - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % o CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V a Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional(') Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect Optimized installation with HD-Wave technology 9Y STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 / Specifically designed to work with / Extremely small Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) power optimizers Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS Record-breaking efficiency / Built-in module-level monitoring AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG Fixed voltage inverter for longer strings / Outdoor and indoor installation AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8/450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm / Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data,ANSI C12.20 Weight with Safety Switch 22/10 25.1/11.4 126.2/11.9 38.8/17.6 Ib/kg NEC 2014 and 2017,per article 690.11 and 690.12 Class 0.5(0.5%accuracy) Noise <25 1 <50 dBA Cooling Natural Convection UL1741 SA certified,for CPUC Rule 21 grid Operating Temperature Range -13to+140/-25to+601^1(-40°F/-40°Coption)"' °F/°C compliance Protection Rating NE MA 4X(Inverter with Safety Switch) m For other regional settings please contact SolarEdge support A A higher current source may be used;the inverter will limit its input current to the values stated solar Revenue grade inverter P/N ion reSExxxfer to:htt sN/ w for pourer de-rating information refer to:httpsy/wwwsolaredge.com/sites/default/files/se-temperature-denting-note-na.pdf so I a red g e.com 61-40 version P/N:SEx—H-USOOONNU4 ®SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All RoHS other trademarks mentioned herein are trademarks of their respective owners.Date:03/2019N01/ENG NAM.Subject to change without notice. /l IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. v v u�. Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of i ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results.They resist uplift, protect \� XR10 XR100 XR1000 against buckling and safely and efficiently ®�® XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among transfer loads into the building structure. ® rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle Their superior spanning capability Q A® ' no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. requires fewerroof attachments, reducingthe number of roof ` 6'spanning capability 10'spanning capability 12'spanning capability penetrations and the amount �� Moderate load capability Heavy load capability Extreme load capability Clear black anodized finish Clear black anodized finish Clear anodized finish Of installation time. Internall splices available Internal splices available Internal splices available ♦ `�� Rail Selection IThe table below was prepared in compliance with applicable engineering codes and standards.*Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. L Wft . . �' 90 Force-Stabilizing Curve ' Sloped roofs generate both vertical and lateral 120 forces on mounting rails which can cause them None to bend and twist.The curved shape of XR Rails 140 XR10 XR100 XR1000 is specially designed to increase strength in both directions while resisting the twisting.This unique 160 feature ensures greater security during extreme weather and a longer system lifetime. 90 120 20 140 160 9 30 0 160 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 XR Rails are Iron Ridge offers All XR Rails are made of 6000-series 40 compatible with �3� a range of tilt leg aluminum alloy,then protected with an , 160 A FlashFoot and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing . 80 160 attachments. applications. a more attractive appearance. 120 160 "Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. /lam IRONRIDGE FlashVuell See Your Pilot Holes Moving Flashing Forward _ _ • 'e Viewport in Flashing -- FlashVue makes pilot visible,like never before.No more i• We set out to design a flashing that checked all tedious guessworkroofs. the boxes: fully waterproof, fast and easy to install correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. 41* i The optimized flashing design features a large viewport, for easy alignment with the pilot hole.And the GripCap and GripCap+ sit snugly in place, so III�III`IIII� the lag can be driven single-handedly. , TIT „M mow L Solve Roof Undulations Three-Tier Water Seal, Reimagined FlashVue's seal architecture utilizes three layers of protection.The viewport is elevated 0.30",andAvailable: provides a"friction-fit"for the GripCap.The GripCap fully covers the viewport while a sealing washer alwaysWe know roofs are not adds another layer of protection.And an EPDMperfectly flat.GripCap+can help ___s washer and lag bolt"seal the deal"in the stack. undulations _, 1^airipCap —__s 7— — - GripCap&GripCap+ The 360'capable GripCap(2.74" --_--_== a� '—�- ( �^ tall)and GripCap+(3.74"tall)can be — 1": ■■■��_�__�__� ___ E__ ----- - =-- placed in any orientation,and provide a _T _ " --- "friction-fit'for easy installs.Push snug ____-_�� 11f into the viewport,without worrying it will i (r1pC' roll away or rotate while driving the lag. ____ — — s110***do )S \� Trusted Strength & Certification �\�`� � ��► �� ', D 0 75" Attachment Loading \\ �` ���1�t,,, �, ►a� h FlashVue has been tested and rated to support 1161 (Ibs) of uplift and 353 (Ibs) of lateral load. Structural Certification Designed and certified for compliance with the International Building Code &ASCE/SEI-7. Eta�S Large Viewport in Flashing � Water Seal Ratings Intertek '_ i���! The large viewport makes it easy to C�'� ��� align the flashing with the pilot hole,and Passed both the UL 441 Section 27"Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Triple Certified to 0 �' �'�,._____ =— drive the lag centered into the rafter.The Protect the Roof'"" at ar = elevated rim not only provides a sturdy UL 2703 Listed System UL 2703,441 (27) ° dock for the GripCap or GripCap+,but TAS 100(A)-95 increases water-shedding capabilities. L Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info. �/lr 0 2020 /lr�